Data sheet: Wilo-VeroLine-IPL 65/145-5.5/2 Pump curves 2-pole, 5 Hz H[m] 3 25 15 5 Qmin IPL 65/155-5,5/2 Wilo-VeroLine-IPL 65/155 - Wilo-VeroLine-IPL 65/145 IPL 65/145-5,5/2 IPL65/155-7,5/2 5 3 4 5 6 7 8 9 1 1Q[m³/h] 3 Q[l/s] P 2 [kw] 8 6 Ø126 4 2 3 4 5 6 7 8 9 1 1Q[m³/h] η p[%] 8 6 4 3 4 5 6 7 8 9 1 1Q[m³/h] Dimension drawing Ø 279 NPSH [m] DN 65 15 Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures (for -4 vol.% glycol and fluid temperature 4 C) Cooling and cold water Heat transfer oil Permitted field of application Standard version for operating pressure Special version for operating pressure p max p max Temperature range at max. ambient temperature +4 C Special version at additional charge bar 16 bar -...+1 C (depending on the fluid) Max. ambient temperature +4 C Installation in closed buildings Outdoor installation Pipe connections Special version at additional charge 15 Nominal flange diameter DN 65 4 x Ø 19 Ø 118 Ø 145 Ø 185 Flanges (according to EN 92-2) Flange with pressure-measurement connections PN (PN 16 on request) R 1 / 8 531 1 II 6 Note: II III 3 x M12 279 112 134 c 6 34 188 14 16 Housing with feet for installation on a base, brackets on request; II Pressure measuring connection R1/8; III Ventilation R1/8 Materials Pump housing EN-GJL-25 Lantern EN-GJL-25 Impeller EN-GJL- Impeller (special version) Pump shaft 1.421 [AISI4] Mechanical seal AQEGG Other mechanical seals On request Terminal diagram W2 U2 V2 U1 V1 W1 L 2 L 1 L3 PE W2 U2 V2 U1 V1 W1 L 2 L 1 L3 PE : Connection diagram delta connection Y: Connection diagram star connection Motor protection switch required on-site. Check the direction of rotation! To change the direction of rotation, exchange any two phases. P 2 3 kw P 2 4 kw 3~4 V Y 3~23 V 3~69 V Y Subject to change without prior notice. 3~4 V www.wilo.co.uk 5 Hz 15-2 1 / 8 After removing the bridges, Y- start is Electrical connection Nominal speed n 29 rpm Minimum Efficiency Index (MEI) Minimum Efficiency Index (MEI).4 Pump with max. impeller diameter for determining the MEI Motor/electronics IPL65/155-7,5/2
Data sheet: Wilo-VeroLine-IPL 65/145-5.5/2 Integrated full motor protection Special version with PTC thermistor sensor (KLF) at additional charge Protection class IP 55 Insulation class F Rated current (approx.) I N 3~4 Motor efficiency level V.2 A IE2 Motor efficiency Power factor η m /η 5% m /η 75% m % cos φ 86.7/88./87. %.87 Nominal motor power P 2 5.5 kw Motor winding up to 3 kw Motor winding from 4 kw 23 V Δ/4 V Y, 5 Hz 4 V Δ/69 V Y, 5 Hz Installation options Pipe installation ( 15 kw motor power) Support-bracket mounting Information for order placements Weight approx. m 74 kg Make Wilo Type VeroLine-IPL 65/145-5.5/2 Art no. 8967 Observe motor name plate data Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-2 2 / 8
Dimensions and dimension drawings: Wilo-VeroLine-IPL 65/145-5.5/2 Dimension drawing Ø 279 DN 65 4 x Ø 19 15 Ø 118 Ø 145 Ø 185 531 188 II II III 112 1 c 3 x M12 134 279 6 6 14 16 34 Note: Housing with feet for installation on a base, brackets on request; II Pressure measuring connection R1/8; III Ventilation R1/8 Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-2 3 / 8
Pump curves: Wilo-VeroLine-IPL 65/145-5.5/2 Pump curves 2-pole, 5 Hz H[m] 3 25 Qmin IPL 65/155-5,5/2 Wilo-VeroLine-IPL 65/155 - Wilo-VeroLine-IPL 65/145 IPL 65/145-5,5/2 IPL65/155-7,5/2 15 5 3 4 5 6 7 8 9 1 1Q[m³/h] NPSH [m] 15 5 3 Q[l/s] P 2 [kw] 8 6 Ø126 4 2 3 4 5 6 7 8 9 1 1Q[m³/h] η p [%] 8 6 4 3 4 5 6 7 8 9 1 1Q[m³/h] Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-2 4 / 8
Ordering information: Wilo-VeroLine-IPL 65/145-5.5/2 Information for order placements Make Wilo Type VeroLine-IPL 65/145-5.5/2 Art no. 8967 EAN number 41632299789 Colour Green Minimum order quantity 1 Minimum order quantity unit PCE Weight (net) kg 74.2 Length (net) mm 65.5 Width (net) mm 279 Height (net) mm 34 Weight (gross) kg 76.6 Length (gross) mm 78 Width (gross) mm 38 Height (gross) mm 45 Packaging type Cardboard box Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-2 5 / 8
Specification texts: Wilo-VeroLine-IPL 65/145-5.5/2 Single-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With forced-flow circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller. Flange with R 1/8 pressure measuring connections. Pump housing and lantern are cataphoretic-coated. Materials Pump housing: EN-GJL-25 Lantern: EN-GJL-25 Impeller: EN-GJL- Pump shaft: 1.421 [AISI4] Mechanical seal: AQEGG Permitted field of application Standard version for operating pressure: bar Temperature range at max. ambient temperature +4 C: -...+1 C (depending on the fluid) Max. ambient temperature: +4 C Pipe connections Nominal flange diameter: DN 65 Flanges (according to EN 92-2): PN (PN 16 on request) Flange with pressure-measurement connections: R 1 / 8 Overall length: 34 mm Minimum Efficiency Index (MEI) Minimum Efficiency Index (MEI):.4 Pump with max. impeller diameter for determining the MEI: IPL65/155-7,5/2 Motor/electronics Protection class: IP 55 Insulation class: F Rated current (approx.):.2 A Motor efficiency level: IE2 Motor efficiency: 86.7/88./87. % Power factor:.87 Nominal motor power: 5.5 kw Nominal speed: 29 rpm Weight Weight approx.: 74 kg Information for order placements Art no.: 8967 Type: VeroLine-IPL 65/145-5.5/2 Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-2 6 / 8
Specification texts: Wilo-VeroLine-IPL 65/145-5.5/2 Make: Wilo Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-2 7 / 8
Terminal diagram : Wilo-VeroLine-IPL 65/145-5.5/2 Terminal diagram W2 U2 V2 U1 V1 W1 W2 U2 V2 U1 V1 W1 : Connection diagram delta connection Y: Connection diagram star connection Motor protection switch required on-site. Check the direction of rotation! To change the direction of rotation, exchange any two phases. P 2 3 kw P 2 4 kw 3~4 V Y 3~23 V 3~69 V Y 3~4 V L 2 L 1 L3 PE L 2 L 1 L3 PE After removing the bridges, Y- start is possible. Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-2 8 / 8