HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

Similar documents
PART MATERIAL PART MATERIAL. Casing Hot galvanized steel / Option: stainless steel EN (AISI316L) Reheat coil EN 1.

HML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating

HME SINGLE DUCT CABIN UNIT CABIN UNITS HME. Sound attenuator and balancing box

Casing Hot galvanised steel / Option: stainless steel EN (AISI316L) Reheat coil EN (AISI 304)

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

VARYCONTROL VAV Dual Duct Terminal Boxes

VAV Terminal Units SDS

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

J L I e x h a u s t h o o d

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

VAV controller. TROX Auranor Norge AS. Telephone Fax

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

VAV TERMINAL BOXES TYPE: BA BT

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

CONSTANTFLOW Volume Flow Controllers

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

Technical information

BLBd

KSOF Fire damper valve

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

Ceiling swirl diffusers

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

EXCa. Exhaust register

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

TBV - Terminal Unit. Halton TBV. Terminal Unit

NV series. Induction VAV air volume control terminals

4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en)

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Extract-air grille with ATK plenum box

KSOM Control exhaust valve

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

ULA - Valve. Halton ULA. Valve

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

QUIETSCROLL TWIN FAN RANGE

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

RECTANGULAR VAV DAMPER TECHNICAL CATALOGUE

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

7/S5 FIRE DAMPER FD40. v 2.9 (en)

BOX - Airflow management unit BOX. Airflow management unit. Solution. Options & Accessories

RETROFIT TERMINAL UNITS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

SERENO

RWBa. ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. RWBa

Dual Duct Terminal Units Part Two

Pressure control damper ERPA

Volumetric Flow Limiter VOLKOM

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

TUBUS TUBUS. Key figures. Function Wall-mounted supply air diffusers

Variable Air Volume (VAV) Pressure Independent Control

CAV controllers Type RN

MIRUVENT. Power roof ventilator with 27 different airflow variants up to 24,000 m 3 /h

RVP-R- VAV controller. In explosion-proof version

Swegon PACIFIC. Integrated climate beam QUICK FACTS KEY FIGURES

Swegon PACIFIC. Integrated climate beam

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Aircell Polymer Range

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Models: 12 and 18. Models: 24 to 60

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Fan - Powered Terminal Unit Series Flow

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

CTVK Supply air diffuser

Regulation and shut-off damper SPB and SPC

Transcription:

HMR DUAL DUCT CABIN UNIT For passenger and crew cabins APPLICATIONS Halton HMR is pressure independent dual duct cabin unit. The airflow is continuously measured from the warm air spigot, as well as for total air volume. Pressure independent HMR adapts to variations in ductwork pressure and maintains individual conditions in each cabin. MATERIALS PART MATERIAL NOTE Casing Hot galvanized steel Available as an option: stainless steel EN 1.4404 (AISI316L) Spigots Insulation Hot galvanized steel and EPDM rubber Mineral wool, s=25 mm, MED approved I/O unit Aluminium / plastic / electronics Cables Airflow measurement probes and tubes Halogen free Aluminium / polyurethane - HMR PRODUCT OPTIONS Pressure independent model (VAV/CAV) Available as an option: stainless steel EN 1.4404 (AISI316L) Inputs for external switches such as balcony door and key card switches available as an option - - FEATURES Pressure range from 200 Pa up to 1000 Pa Airflow range 120 m3/h...400 m3/h 230 VAC ±10%%, 50/60 Hz Inbuilt airflow measurements Master/slave functionality: several cabin units can be controlled by one control panel Internal fuse included All parameters can be set onsite during commissioning by external device or preset at the factory Different regulation principles available according to supply air temperatures (see regulation diagrams) HMR cabin unit is supplied with control panel and interconnection cable MED approved for B-0/B-15 installations Network compatible with adapter for advanced energy efficiency and supervision system available as an option Energy efficiency functions to reduce unnecessary cooling / heating costs available as an option 1

GENERAL HMR DRAWINGS 240 Ø99 Ø124 250 110 40 600 480 60 WARM COOL D1 10 60 40 40 HMR DIMENSIONS H ØD1 male/ female Ø warm duct/ Ø cool duct HMR-240 240 249/251 99/124 Note: male connection: outer dimension, female connection: inner dimensions 300 250 500 620 D1:female=Ø252 int. M06Y2018/Halton Marine reserves the right to alter products without notice. FUNCTION Control panel includes also a number of special features such as diagnostics function, room brightness measurement and re-programmability. The power supply and data transfer between cabin unit and control panel is carried out via interconnection cable.temperature range is software adjustable between 10 and 30 C degrees. FUNCTION OF VAV UNIT When passenger demands for a lower temperature, the damper opens the cold air duct in order to increase of flow of cool air towards to maximum setpoint. Simultaneously the damper closes the warm air duct. When the required temperature in the cabin is achieved, the damper references are held until the temperature demand changes. In a heating mode, the operation is reserved. FUNCTION OF CAV UNIT Airflow is kept in pre-set level in any condition. When passenger demands for a lower temperature by using control panel, the damper opens the cold air duct in order to increase of flow of cool air. Simultaneously the damper closes the warm air duct. When the required temperature in the cabin is achieved, the damper references are held until the temperature demand changes. In a heating mode, the operation is reserved. REGULATION DIAGRAM, VAV Airflow Max Min Warm supply air Cold supply air Total supply air REGULATION DIAGRAM, CAV Airflow Max Min Warm supply air Cold supply air Total supply air Temp C Temp C OPERATING RANGE FOR HMR HMR-240 120 m 3 /h - 400 m 3 /h CABIN UNIT S AIRFLOW MEASUREMENT ACCURACY AIRFLOW (m 3 /h) 120-150 151-200 201-300 301-400 Accuracy* ±20% ±15% ±10% ±8% * ductwork pressure 200-1000 Pa (optimal) Note: When comparing airflow measurements between cabin unit and other device, cabin unit s airflow regulation dead-band has to be taken into account ( 10 m 3 /h). 2

CONTROL PANEL FEATURES Halton Marine HMF cabin units are available with three different control panel models; with rotating knob, push buttons with LED bar graph (available as option: IP54) and push buttons with LCD-display (available as option: IP54). COMMON FEATURES Cabin temperature measurement Connector for bluetooth / communication adapter to set cabin parameters Software for parameter setting and trouble shooting Control panel models; push button and rotating knob Different colour options and custom labeling available as an option Delivered with IC-Cable (interconnection cable) For control panel - cabin unit connection Prefabricated with plugs on both ends Cable plug on panel side is designed to be pulled through standard installation pipe Halogen free and flame-retardant Standard length 7 meters. Other lengths available. LCD control panel CONTROL PANEL WITH ROTATING KNOB Temperature adjustment by rotating knob CONTROL PANEL WITH PUSH BUTTONS AND LED BAR GRAPH Temperature adjustment by push buttons Self diagnose function LED intensity control and auto dimming CONTROL PANEL WITH PUSH BUTTONS AND LCD- DISPLAY Temperature adjustment by buttons Self diagnose function LCD intensity control and auto dimming Display for actual and set point temperatures available as an option Time display available as an option A customized background picture available as an option Several frame options available 3

M06Y2018/Halton Marine reserves the right to alter products without notice. CABIN VENTILATION CONFIGURATION TABLE TERMINAL UNIT WITH JUNCTION BOX CONTROL PANEL CABLES UNIT HMM HMM HME HME HMF HMF HMF HFR/M HFR/M HFR/M HMR HMR HML CONTROL PACKAGE K01 D03 K01 D03 M00 M01 M02 M00 M01 M02 D21 H21 B00 Damper manual manual manual manual electric electric electric electric electric electric electric electric electric Airflow measurement and control (VAV, CAV) In-box temperature measurement Reheater safety switch, manual reset Safety switch state detection Spare inputs (balcony door etc.) Parameter setting by service tool Cabin temperature measurement Controller with push buttons, 18 led bar no no no no yes no yes yes no yes yes yes yes yes yes yes yes yes yes yes yes yes yes no no yes yes yes yes yes yes yes yes yes yes yes no no yes no yes no yes yes yes yes yes yes yes no no yes no no no no yes yes yes yes yes yes yes yes yes no yes no yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes Controller with knob yes no yes no no yes yes no yes yes no yes no LCD room thermostat no optional no optional optional no no optional no no optional no optional LED intensity control and auto dimming Self diagnose functionality Network compatible with adapter CO2 sensor available as an option no yes no yes yes yes yes yes yes yes yes no yes Interconnection cable IC4-X IC6-X IC4-X IC6-X IC6-X IC6-X IC6-X IC6-X IC6-X IC6-X IC6-X IC6-X IC6-X Master-Slave cable MS4-X MS2-X MS4-X MS2-X MS2-X (MS5-X) Please note: HMM and HME units are also available without a control package. MANUALLY CONTROLLED AIRLOWS Single duct units; HMM, HME PRESSURE DEPENDENT UNITS Single duct units; HMF, HFR/M MS3-X MS3-X MS2-X (MS5-X) MS3-X MS3-X MS2-X MS3-X MS2-X PRESSURE INDEPENDENT UNITS Single duct units; HMF, HFR/M, HML Dual duct units; HMR 4

ACCESSORIES FOR HMR CABIN UNITS MS-CABLE (MASTER-SLAVE CABLE) For master cabin unit - slave cabin unit/units connection Prefabricated with plugs on both ends Halogen free and flame-retardant Standard length is 7 meters. Other lengths available as an option. COMMUNICATION ADAPTER Bluetooth communication to external device For wireless connection to set cabin unit parameters and trouble shooting NETWORK ADAPTERS Network adapter (also available as WiFi) expands a stand-alone unit to network compatible unit (LON or Ethernet network) Enables supervision and advanced energy efficiency functions For more information, see Halton Networks for cabin ventilation -brochure or contact Halton Marine Sales office. 5

PERFORMANCE DATA SOUND LEVELS, CABIN SOUND ABSORPTION 4 db(a) HMR-100/125-200 Ptot 850 Pa Ptot 500 Pa Ptot 250 Pa HMR-100/125-250 Ptot 850 Pa Ptot 500 Pa Ptot 250 Pa PRESSURE DROP M06Y2018/Halton Marine reserves the right to alter products without notice. HMR-100/125-200 HMR-100/125-250 SOUND ATTENUATION (db) f(hz) 63 125 250 500 1000 2000 4000 8000 HMF-100/125 L(dB) 3,9 8,3 16,9 25,6 35,3 38,6 38,4 37,4 L: Sound attenuation not including end reflection 6