COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING

Similar documents
COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING

NOUVEAULINE EC NOUVEAULINE EC NOUVEAULINE EC NOUVEAULINE EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING

WING WING-R WING WING-R WING-G WING-G WING-R EC & WING-G EC DESIGN AIR CURTAIN FOR VERTICAL INSTALLATION INDIVIDUAL INNOVATIVE ENERGY-SAVING

RONDELL EC RONDELL EC RONDELL EC RONDELL EC RONDELL EC RONDELL EC FOR REVOLVING AND CURVED SLIDING DOORS INDIVIDUAL INNOVATIVE ENERGY-SAVING

CassetteEffect EC. Recessed air curtain

Features: Available in horizontal and vertical units

Air Curtains for Revolving Doors

New standard decorative generation

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

Toshiba EMEA. 14 th June 2012

IDENTIFICATION ACCESSORIES DESCRIPTION

COMFORT AIR CURTAIN. SensAir

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

COMFORT AIR CURTAIN. SensAir

8/S3 8/S1 AIR CURTAINS AIR CURTAINS SONATA, SONATA-V SONATA, SONATA-V. v 3.1 (en) v 1.0 (en) Design changes reserved

COMFORT AIR CURTAIN. SensAir

TTL-TREND -10/15/LNX Energy saving air curtain systems with EC-fan technology

technical catalogue tetris KW Chiller and heat pumps air/water

Air Curtains for Revolving Doors

TTL-TREND -5/8/LNS/HE Energy saving air curtain systems with EC-fan technology

Comfort Door Air Curtains. Li, Li EC.

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

Trench Heating/Cooling. Katherm HK. Tested acc. to: BS EN 16430

Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise

Total cooling capacity kw Total heating capacity kw Features

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

(ULT200-UM.x-HFM050) Technical Documentation

something new in the air Technical Bulletin

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

(UK) Date : January 2014

AHN 064 to 304 EHN/CHN 064 to 304

Heat Exchangers. Evaporator Catalogue

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Fan coil units MAJOR 2 CV/CH

C RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains

Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min RAMIRENT

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

KLIMA Active Chilled Beams

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

Technische Information. Electronically controlled cooling. Reason for the development. Changes compared with the conventional cooling circuit

Innovative, High Performance, Quiet Units.

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

(ULT300-UM.x-HFM050) Technical Documentation

Air-Cooled Liquid Chiller with integrated hydraulic module

INSTRUCTION MANUAL. Air Curtains Rund (M, G)

modular multi intelligent, environmental and versatile

Fan coil unit NBS 100/150

Heat Meter Integrator

CENTRIFUGAL FAN COIL UNIT VCE

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

EURUS / EURUS-I. Conditioning your ambient, maximising your comfort.

Accessories. Series REC

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

DA Control modules (VCS-R-DA-..)

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Küba SG industrial

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

AIR CURTAIN DESIGNER C RANGE Horizontal and Vertical

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Linear Valve Electric Actuator

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Fault Codes. J control

Multi directional heating. Air heaters Model NOZ

ARW DRY COOLERS AXIAL FANS VERSION, MEDIUM AND HIGH CAPACITY. CAPACITY FROM 20 TO 775 kw ARW DRY COOLERS

BUILDING AUTOMATION CONTROL TECHNOLOGY SENSOR TECHNOLOGY PRODUCT CATALOGUE Intelligent solutions for intelligent people.

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

COMPRESSORS MOBILAIR M 115. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 7.5 to 11.5 m³/min ( cfm)

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

Engine Emission Control 6.7L Diesel

X100P Load Bank. Read all instructions before using the load bank. Contents

Industrial air curtains

SPECTRACOOL SLIM FIT AIR CONDITIONERS EQUIPMENT PROTECTION

Sentry. Door Curtain. Energy efficient EC motors Cased and concealed models LPHW and electric heating Comprehensive range of controls

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

PHV V NT VERTICAL AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

record your global partner for entrance solutions record CURVED Sliding doors for any conceivable radius CURVED

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

EPS/ELA-Series User Manual EPS/ELA 250W

Portable Compressors MOBILAIR M 123 With the world-renowned SIGMA PROFILE Free air delivery 11.4 m³/min.

Transcription:

DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING

DESIGN AIR CURTAIN Aluminium profile discharge fins (drop form) for optimum airflow Elegant steel-composite design high-quality powder coated or with stainless steel housing Attractive intake grille with micro-intake grille behind it Applications With its suspended and standing versions, Colum EC is particularly suited to the visible parts of modern entry areas and, thanks to its rounded design and low maintenance operation, will satisfy architects, planners, clients and operators. The floor mounted vertical unit is particularly suited to revolving doors, since the heated airflow is discharged directly all the way down to the floor level without losing heat, thus preventing the formation of a "cold patch". The choice of standard RAL powder coatings or the stainless steel housing fit superbly in existing entry areas. Colum EC is used in hotels, banks, flagship stores, shopping malls, airports and public buildings. Special design Colum EC is available in variable housing lengths up to 3 m. It is simple to retrofit the floor mounted vertical unit in existing door systems. The housing Self-supporting steel-composite construction in a cylindrical shape with split sheet steel or stainless steel housing (polished to grain size 240) in a round-rolled design. Screws and rivets are not visible. 2 Powder coated intake grille in the same colours as the unit or stainless steel version, consisting of a perforated plate with micro grille behind it for easy maintenance application. Aluminium discharge grille for an infinitely adjustable, unidirectional air stream Invisible energy connections for the floor mounted vertical unit (discreetly bolted in place via holes in the floor plate). Heating media Heat exchangers for different heating media LPHW: for normal temperature LPHW 70/50 C and low-temperature LPHW 60/40 C, other temperatures available on request. DX: DX register soldered under nitrogen for operation with heat pumps (only heating modus possible). High-quality heat exchanger made from copper tubes, with pressed-on, extra-strong aluminium fins. ELECTRO: 3-stage heat exchanger 400V, spiral form, corrosion resistant, with thermal overheating protection and switch-off delay.

Advantages at a glance Made in Germany ErP conform / EC fans Certified by TÜV-Süd Individual colours standard RAL colours available alternatively as stainless steel version Individual unit lengths up to 3000 mm Service-friendly thanks to filterless micro-intake grille Aluminium profile discharge fins (drop form) for optimum airflow Large throw distance, low noise, optimum shielding Different heating media possible Simple to install EC fans The efficiency of the EC fans used by TEKADOOR is > 90% under partial load operation. This is 30 35% higher than for conventional AC fans. This does not just increase the efficiency, but also reduces the operating costs. The individually-driven EC fans with integrated motor protection can intake air in both directions. They have vibration-free bearings and are controlled using a PWM signal (pulse width modulation) and with 0-10 V for the DX. They do not just comply with Directive ErP, but actually exceed this standard. Mounting Floor mounted vertical unit: Problem-free mounting via holes in the floor plate directly on the finished flooring. The floor plate has appropriate recesses for invisible energy supply from below. Optional: Power supply is also possible from above. Suspended version: simple mounting thanks to the M8 rivet nuts incorporated on the upper side of the unit as well as optionally-available assembly materials. Maintenance Easy to clean (micro grille) without opening the unit by simply vacuuming the intake grille. The intake grille must be removed before the revision panel can be opened. To do this, a cross-headed screw at the upper end of the intake grille must be removed. Then the intake grille can be taken out of the lower frame. Control Electronic TEKADOOR GTC EC control unit, multifunctional with touch display, including an optional ModBus interface A GTC 1 EC control unit is used as standard for models with LPHW heating. A GTC E EC control unit is used for models with electrical heating. The units come with 20 m preassembled and shielded data cable. The GTC 1 EC 5-stage control unit includes the ability to switch from manual to automatic and from summer mode to winter mode as standard. A solenoid valve of up to 2.5 A can be connected as an option for the winter mode. With the standard GTC E EC control unit, the airflow can be selected manually in 5 stages and the heating capacity depending on the fan level can be selected manually in 3 stages. Each control unit includes a manual to automatic mode switch and a potential-free contact for enabling via any on-site BMS or BEMS. A choice of 5-stage or stepless fan operation is offered as standard. A maximum of 10 units can be connected in parallel. 3

DETAILS Connections Floor mounted vertical unit Heating connections flow and return for easy connection to the on-site heating system. - Connections for the floor mounted vertical unit: either from below or above, invisible within the door air curtain. Connection box Simple electrical connection of the power supply 230 V/50 Hz thanks to the internal connection box. Exception: Electrical units with a heating capacity greater than 22.5 kw. - for the suspended version: on the upper side of the unit (or optionally from the side) 4

Data cable connection/interface Discharge fins Standard connection options for the data cable and an optional solenoid valve or thermo-electric shut-off valve within the unit. Simple plug and play of the data cable. Control: Input for the data cable to the control unit. Auxiliary: Output for parallel operation with other units. Discharge grille with aluminium fins (drop profile), depending on the model available in designs with double or multiple fins, for an infinitely adjustable, unidirectional air stream. During the heating period, the fins should be tilted outwards by 10 to 15 degrees to prevent cold air coming in from the outside. In contrast, during operation in the summer, the fins are tilted inwards, so that the cooled indoor air cannot escape. 5

COL 6

FLOOR MOUNTED VERTICAL UNIT stehende Geräte stehende Geräte J SUSPENDED UNIT hängende Geräte hängende Geräte 80 80 J 40 F 40 F D D A A A A RL RL VL VL AUßEN TÜRE AUßEN TÜRE VL VL RL RL F D Modell Zeichenerklärung D A D E F J Modell Zeichenerklärung A D E F J 2000 400 80 230 150 3000 400 80 230 150 2000 400 80 230 150 4000 600 110 320 200 3000 400 80 230 150 5000 600 110 320 200 4000 600 110 320 200 6000 600 110 320 200 5000 600 110 320 200 6000 600 110 320 200 Längenmaß variabel Längenmaß variabel A = VARIABLE UNIT LENGTH F E E stehend LINKS stehend LINKS ACHTUNG ACHTUNG Montage nur auf dem fertigen Montage Fussboden! nur auf dem fertigen Fussboden! gezeichnet/signet geändert/revision INNEN GEBÄUDE INNEN GEBÄUDE Name ma gezeichnet/signet geändert/revision Datum 21.03.2011 Name ma Werkstoff Datum 21.03.2011 Kundenzeichnung Nr.: Benennung Albert-Einstein-Str. 11 Name D-40764 Langenfeld Kunde Tel.: 049 (0)2173 20766-0 Fax: 049 (0)2173 Albert-Einstein-Str. 20766-111 11 D-40764 Langenfeld Tel.: 049 (0)2173 20766-0 Fax: 049 (0)2173 20766-111 stehend RECHTS Pos. Werkstoff Erstelldatum von Kunde Pos. Colum Kundenzeichnung 110321 Nr.: Benennung Name stehend RECHTS Technische Änderungen vorbehalten von Colum 110321 Technische Änderungen Maßstab vorb Gruppe Teile Gruppe Erstelldatum Blatt 1 von 1 Teile Connection-ready, free-hanging door air curtain unit for visible installation above the door or as a floor mounted vertical unit. The ambient air intake for the suspended version is from above and from the side for the floor mounted vertical unit. UM7

88 88 25 25 Fixing OUT IN 30 30 50 50 DOOR SIDE 50 E. Connection 147 Fixing 238 ø 400 24 168 INSTALLATION ON THE LEFT Fixing Floor 10 54 Floor plate with all relevant dimensions for a floor mounted vertical unit. COL Shown here installed on the left. 8

88 88 25 25 DOOR SIDE Fixing IN OUT 50 30 30 50 147 50 E. Connection ø 400 Fixing 24 238 168 INSTALLATION ON THE RIGHT Fixing Floor 10 54 Floor plate with all relevant dimensions for a floor mounted vertical unit. Shown here installed on the right. UM 9

2 STANDARD CIRCUIT DIAGRAM FOR LPHW Fr 21.09.2018 07:52 Heat level 0 / 0 Automatic Hand Room Temp 10 C Fan level 0 / 0 Timer off Room temperature. Sensor installed ModBus interface (optional) 1 2 3 to input (CONTROL) next PCB Address 1-9 8 8 Standard suppled shielded datacable (20 m) with RJ-45 connectors Magnetic valve (OPTIONAL) L N PE 1 M next Fan MOD Bus 1 2 3 4 RJ 45 ON AUX AUXILIAR MON CONTROL L2 N PE 230V / 50Hz L2 N PE intern 4 L1 N PE weiss/white imp. PCB EC gelb/yellow blau/blue rot/red Y 0-10 V 0 V 10 V CPU 9 8 0 1 7 6 5 4 3 Address switch 0 = MASTER 1-9 = SLAVE F 16 AT 1 11 2 12 3 13 4 14 5 15 BMS On/Off nicht belegt Frost protection thermostat ext. Contact Roomtemp. sensor q 6 16 7 17 8 9 10 18 19 20 not used not used fault Operation L N PE 3 Connecting box Main switch and fuses to be installed by third parties must comply to all applicable rules and requirements! optional optional optional 230V/ 50Hz gezeichnet/signet Name la Datum 02.01.2019 Werkstoff Benennung Name Kunde Technical changes reserved CONTROL UNIT GTC 1 EC Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and Maßstab energy-saving EC fans. A standard feature of the control unit with touch display is a choice between Pos. von Gruppe Teile 5-stage or stageless fan control, which can be selected individually by the operator. The relevant operating modes and symbols are Erstelldatum arranged clearly on the colour display. The date, time and room temperature are shown as standard. The room temperature is monitored via an internal temperature sensor in GTC the control I EC unit as 190102 standard. Kundenzeichnung Nr.: Blatt 1 von 1 An easy-to-navigate menu offers a selection of different operating modes: Hand manual operation Auto AS automatic operation via cool down protection Auto RT automatic operation via room temperature Auto TK automatic operation via door contact Auto Kombi option to combine all individual automatic modes 10 An enabling contact and potential-free operation and malfunction signals are provided for control via an on-site BMS or BEMS. Errors and faults are displayed with a red warning sign. By coding the control boards differently, up to 10 door air curtains can also be operated in parallel with 1 control unit, using the Master/Slave principle. The control board is preinstalled in the door air curtain unit and 20 m of preassembled data cable (connection between the door air curtain and control unit) are included as standard.

CIRCUIT DIAGRAM FOR ELECTRICAL HEAT EXCHANGER Fr 21.09.2018 07:52 Heat level 0 / 0 Automatic Hand Room Temp 10 C Fan level 0 / 0 Timer off Room temperature. Sensor installed ModBus interface (optional) K1 K2 K3 1 2 3 to input CONTROL next PCB 8 AUX AUXILIAR Standard supplied shielded datacable (20 m) 1:1 straight wired RJ-45 Stecker q 8 S 80 MON CONTROL q S 60 K1 K1 q S 45 q S 50 L2 N PE 230V / 50Hz L2 N PE intern 4 1 M next Fan L1 N PE MOD Bus 1 2 3 4 RJ 45 ON weiss/white imp. CPU 9 8 0 1 2 gelb/yellow YPWM blau/blue 0 V PCB EC rot/red F 16 AT 10 V 1 11 2 12 3 13 4 14 5 15 BMS On/Off free Frost thermostat optional ext. Signal optional Technical changes reserved 7 6 5 4 3 Adress switch 0 = MASTER 1-9 = SLAVE Room Temp sensor optional q 6 16 7 17 8 9 10 18 19 20 Blow out Temp sensor q free Failure Operation K3 q S 100 K0 K2 step 2 step 1 step 3 = step 1 step 2 1 2 3 4 L N PE 3~400V/ 50Hz 230V/ 50Hz Connecting box Mains switch and fuses to be installed by third parties must comply to all applicable rules and requirements! 3 gezeichnet/signet Name Sa Datum 02.01.2019 Werkstoff Maßstab Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and Pos. von energy-saving EC fans. 5-stage fan operation Gruppe Teile or stageless fan control easy to adjust on the control unit Kundenzeichnung using the touch Nr.: display. The electric Erstelldatum heater can be activated in 3 stages.the relevant operating modes Benennung Name Kunde CONTROL UNIT GTC E EC and symbols are arranged clearly on the colour display. The date, time and room temperature are shown as standard. GTC The room E EC temperature UK 190201 is monitored via an internal temperature sensor in the control unit as Blatt standard. 1 von 1 An easy-to-navigate menu offers a selection of different operating modes: Hand manual operation Auto AS automatic operation via cool down protection Auto RT automatic operation via room temperature Auto TK automatic operation via door contact Auto AT automatic operation via constant discharge temperature Auto Kombi option to combine all individual automatic modes An enabling contact and potential-free operation and malfunction signals are provided for control via an on-site BMS or BEMS. A constant discharge temperature can be set via an optional electronic control valve. This enables optimisation of the shielding performance. A week timer is incorporated as standard, enabling up to 12 different switching times to be programmed per week. Errors and faults are displayed with a red warning sign. By coding the control boards differently, up to 10 door air curtains can also be operated in parallel with 1 control unit, using the Master/Slave principle.the control board is preinstalled in the door air curtain unit and 20 m of preassembled data cable (connection between the door air curtain and control unit) are included as standard. 11

OPTIONAL ACCESSORIES Thermostatic straight-way valve (Setting range 20 C to 35 C) limits the discharge temperature (constant supply air temperature limitation). Also available as a 3-way valve. Thermo-electric shut-off valve 230V/50 Hz, normally closed. On-site installation in the heating flow. Actuation via the summer/winter circuit. Summer function closed. Winter function open. Door contact solenoid switch In automatic mode switches on the door air curtain in the preselected stage. 12

Frost protection thermostat For monitoring LPHW heat exchangers exposed to the risk of frost. As soon as the temperature falls below 7 C, the fans are switched off and an optional solenoid valve is opened. Solenoid valve Opens or closes the heating water circuit in the summer/winter setting of the control unit, to close the heating water circuit during summer operation or when the air curtain is not working (normally closed). Caution: If solenoid valves or thermoelectric shut-off valves are used, it is expressly recommended to install a frost protection thermostat (automatically actuated) and a strainer. Electronic control valve Electronic valve with 0-10V impulse and blow-out temperature sensor completely installed and wired. In combination with the GTC 2 control, a preselected blow-out temperature is kept constant. 13

2000 TECHNICAL DATA Design based on: recommended operating point intake temperature tle = 20 C discharge temperature tla = 34 C throw distance = up to 2.50 m 2000 2001 2001.5 2002 2002.5 2003 Air quantity max. m 3 /h 1800 2700 3600 4500 5400 Heating capacity rated 1 LPHW 70 / 50 C kw 8.5 12.7 17.0 21.2 25.5 LPHW 60 / 40 C kw 8.5 12.7 17.0 21.2 25.5 Flow rate LPHW 70 / 50 C m 3 /h 0.37 0.56 0.75 0.93 1.30 LPHW 60 / 40 C m 3 /h 0.37 0.55 0.74 0.92 1.29 Water resistance LPHW 70 / 50 C kpa 0.5 5.7 2.4 3.2 4.1 LPHW 60 / 40 C kpa 3.8 7.0 4.5 3.2 4.2 Nominal connection sizes Internal thread Inches 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4" Flow/return DN 20 20 20 20 20 EC fans Voltage V 230 / 1 / N / PE Frequency Hz 50 Current consumption A 2.1 3.1 4.1 5.1 7.2 Motor power kw 0.3 0.5 0.6 0.8 0.9 Electric heater 3-stage Voltage V 400 / 3 / N / PE Frequency Hz 50 Heating capacity kw 3/6/9 4/8/12 6/12/18 6/12/18 10/20/30 Sound pressure level 2 Highest setting db(a) 58 59 60 61 62 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 3000 Diameter mm 400 400 400 400 400 Weight kg 50 70 90 100 134 1. Rated operation based on operating point (see above), discharge temperature control recommended. 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. A well-balanced pressure ratio is one of the prerequisites for perfect function. 14

3000 TECHNICAL DATA Design based on: recommended operating point intake temperature tle = 20 C discharge temperature tla = 34 C discharge height = up to 2.80 m 3000 3001 3001.5 3002 3002.5 3003 Air quantity max. m 3 /h 2700 3600 5400 6300 7200 Heating capacity rated 1 LPHW 70 / 50 C kw 12.7 17.0 25.5 29.7 34.0 LPHW 60 / 40 C kw 12.7 17.0 25.5 29.7 34.0 Flow rate LPHW 70 / 50 C m 3 /h 0.56 0.75 1.11 1.31 1.49 LPHW 60 / 40 C m 3 /h 0.55 0.74 1.11 1.29 1.48 Water resistance LPHW 70 / 50 C kpa 0.8 2.8 3.7 5.2 7.2 LPHW 60 / 40 C kpa 1.7 3.7 4.2 6.1 7.2 Nominal connection sizes Internal thread Inches 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4" Flow/return DN 20 20 20 20 20 EC fans Voltage V 230 / 1 / N / PE Frequency Hz 50 Current consumption A 3.1 4.1 6.2 7.2 8.2 Motor power kw 0.5 0.6 0.9 1.1 1.2 Electric heater 3-stage Voltage V 400 / 3 / N / PE Frequency Hz 50 Heating capacity kw 5/10/15 7.5/15/22.5 10/20/30 10.7/21.4/32 10.7/21.4/32 Sound pressure level 2 Highest setting db(a) 60 61 62 63 64 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 3000 Diameter mm 400 400 400 400 400 Weight kg 62 77 103 135 145 1. Rated operation based on operating point (see above), discharge temperature control recommended. 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. A well-balanced pressure ratio is one of the prerequisites for perfect function. 15

4000 TECHNICAL DATA Design based on: recommended operating point intake temperature tle = 20 C discharge temperature tla = 34 C throw distance = up to 3.20 m 4000 4001 4001.5 4002 4002.5 4003 Air quantity max. m 3 /h 4500 5100 7300 9800 12000 Heating capacity rated 1 LPHW 70 / 50 C kw 21.2 24.0 34.4 46.2 56.6 LPHW 60 / 40 C kw 21.2 24.0 34.4 46.2 56.6 Flow rate LPHW 70 / 50 C m 3 /h 0.93 1.05 4.51 2.02 2.48 LPHW 60 / 40 C m 3 /h 0.92 1.05 1.50 2.01 2.47 Water resistance LPHW 70 / 50 C kpa 4.5 4.1 9.1 4.4 6.9 LPHW 60 / 40 C kpa 3.2 4.1 3.7 4.5 7.0 Nominal connection sizes Internal thread Inches 2 x 1" 2 x 1" 2 x 1" 2 x 1" 2 x 1" Flow/return DN 25 25 25 25 25 EC fans Voltage V 230 / 1 / N / PE Frequency Hz 50 Current consumption A 6.0 6.5 9.1 12.1 15.0 Motor power kw 1.1 1.4 2.1 2.7 3.5 Electric heater 3-stage Voltage V 400 / 3 / N / PE Frequency Hz 50 Heating capacity kw On request Sound pressure level 2 Highest setting db(a) 64 64 64 65 67 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 3000 Diameter mm 600 600 600 600 600 Weight kg 85 120 160 200 240 1. Rated operation based on operating point (see above), discharge temperature control recommended. 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. A well-balanced pressure ratio is one of the prerequisites for perfect function. 16

5000 TECHNICAL DATA Design based on: recommended operating point intake temperature tle = 20 C discharge temperature tla = 34 C discharge height = up to 3.60 m 5000 5001 5001.5 5002 5002.5 5003 Air quantity max. m 3 /h 4900 7300 9800 12000 14200 Heating capacity rated 1 LPHW 70 / 50 C kw 23.1 34.4 46.2 56.6 67.0 LPHW 60 / 40 C kw 23.1 34.4 46.2 56.6 67.0 Flow rate LPHW 70 / 50 C m 3 /h 1.01 1.51 2.02 4.48 2.93 LPHW 60 / 40 C m 3 /h 1.01 1.50 2.01 4.45 2.92 Water resistance LPHW 70 / 50 C kpa 1.3 2.9 7.9 7.8 9.6 LPHW 60 / 40 C kpa 3.8 2.4 4.7 7.8 9.7 Nominal connection sizes Internal thread Inches 2 x 1 1/4" 2 x 1 1/4" 2 x 1 1/4" 2 x 1 1/4" 2 x 1 1/4" Flow/return DN 32 32 32 32 32 EC fans Voltage V 230 / 1 / N / PE Frequency Hz 50 Current consumption A 6.1 9.1 12.1 15.2 18.2 Motor power kw 1.4 2.1 2.8 3.5 4.1 Electric heater 3-stage Voltage V 400 / 3 / N / PE Frequency Hz 50 Heating capacity kw On request Sound pressure level 2 Highest setting db(a) 63 64 65 66 68 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 3000 Diameter mm 600 600 600 600 600 Weight kg 120 155 200 235 265 1. Rated operation based on operating point (see above), discharge temperature control recommended. 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. A well-balanced pressure ratio is one of the prerequisites for perfect function. 17

COLUM 2000 DX-H EC TECHNICAL DATA ONLY HEATING MODE POSSIBLE Design based on: recommended operating point intake temperature tle = 20 C discharge temperature tla = 34 C throw distance = up to 2.50 m heating gas temperature = 70 C condensation temperature = 50 C condensate exit temp. = 45 C operating pressure = max. 45 bar COLUM 2000 DX-H EC 2001 2001.5 2002 2002.5 Air quantity max. m 3 /h 1800 2700 3600 4500 Power 1 DX heating capacity kw 8.1 12.5 16.9 21.3 Delivery and intake line Connections mm 10/16 10/16 10/18 10/22 EC fans 3 Voltage V 230 / 1 / N / PE Frequency Hz 50 Max. current consumption A 2.4 3.6 4.7 5.9 Max. motor power kw 0.3 0.5 0.7 0.8 Sound pressure level 2 Highest setting db(a) 58 59 60 61 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 Diameter mm 500 500 500 500 Weight kg 50 70 90 100 1. Rated operation based on operating point (see above). 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. 3. Control voltage 0-10 V. A well-balanced pressure ratio is one of the prerequisites for perfect function. 18

COLUM 3000 DX-H EC TECHNICAL DATA ONLY HEATING MODE POSSIBLE Design based on: recommended operating point intake temperature tle = 20 C discharge temperature tla = 34 C throw distance = up to 2.80 m heating gas temperature = 70 C condensation temperature = 50 C condensate exit temp. = 45 C operating pressure = max. 45 bar COLUM 3000 DX-H EC 3001 3001.5 3002 3002.5 Air quantity max. m 3 /h 2700 3600 5400 6300 Power 1 DX heating capacity kw 12.7 17.0 25.7 29.6 Delivery and intake line Connections mm 10/16 10/18 10/22 10/22 EC fans 3 Voltage V 230 / 1 / N / PE Frequency Hz 50 Current consumption A 3.5 4,7 7.1 8.2 Motor power kw 0.5 0.7 1.0 1.2 Sound pressure level 2 Highest setting db(a) 60 61 62 63 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 Diameter mm 500 500 500 500 Weight kg 62 77 103 135 1. Rated operation based on operating point (see above). 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. 3. Control voltage 0-10 V. A well-balanced pressure ratio is one of the prerequisites for perfect function. 19

www.tekadoor.de German headquarters TEKADOOR GmbH Albert-Einstein-Str. 11 D-40764 Langenfeld T. 49 (0) 2173-20766-0 F. 49 (0) 2173-20766-111 E. info@tekadoor.de A = 01.02.2019