Products and solutions for photovoltaic applications

Similar documents
FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

Automatic battery chargers

SWITCH DISCONNECTORS PLANET -SWITCH.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Fuse holders and fuses

GENERAL PURPOSE RELAYS

Switches Unlimited Phone: * Fax:

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Page 2-4 Page 2-8. Page Page 2-13

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

SIRCO M and MV Universal load break switches from 16 to 160 A

For Info: Phone: Fax:

Definite purpose contactors

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

3 - Protection components Motor circuit-breakers

Thermal Overload Relays

Page 2-4 Page 2-8. Page Page 2-12

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Selection Guide Motor Control Device Solutions

COMPLETE SOLUTIONS FOR POWER PROTECTION

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

K50H004UP cam changeover switch - 4-pole A - screw mounting

Cylindrical fuse-link

Electronic overload relay EF65, EF96 and EF146

Square D General Purpose Relays

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

DPX moulded case circuit breakers

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

Manual Motor Starters. Meta-MEC

Thermal overload relay TF65 and TF96

DRX 125 Circuit breaker (not adjustable)

MS General Information Extended Product Type: MS

Electronic overload relays EF205 and EF370

PowerLine OS Switch Fuses A, 690V

PANEL PANEL MOUNTING COMPONENTS

Thermal overload relay TF140DU and TF140DU-V1000

Modular contactors and relays

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

fuse-links & fuse holders PHOTOVOLTAIC

K30H001YP cam star-delta switch - 3-pole A - screw mounting

MOTOR CONTROL AND PROTECTION

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

Selection Guide. Control Circuit and Load Protection

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

DRX 250 B/N/H Circuit breaker (not adjustable)

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

CI-TI Contactors and Motor Starters Type CI 6-50

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

Ktec Contactors and thermal overloads

and other modular devices for low voltage installation

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

INDUSTRIAL CYLINDRICAL FUSE LINKS

DRX 100 B/N/H Circuit breaker (not adjustable)

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

UltraSafe US22 Modular fuse-holders

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

25A 25A 32A 40A 40A 63A 63A 80A

Phase + Neutral, neutral on right side

1 Phase electronic contactor (SC 1)

Phase + Neutral, neutral on left side

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side


S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Solar Installer Range. Bright solutions

Essential equipment for all your requirements

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

SD Series Non-Fused Load Switches

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

AC Switches: ML & MN Series DC Switches: MDC1A Series

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

NB1 Miniature Circuit Breaker

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Softstarters Softstarters

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Safety rope switches with reset for emergency stop

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Transcription:

Products and solutions for photovoltaic applications

Components for string and interface control panels Switch disconnectors Surge protection devices Fuse holders The range of LOVATO Electric components for photovoltaic installations provides the solution to issues related to the control of direct currents where the use of high performance products are needed to ensure essential isolation. L1 L2 L3 N Voltage and frequency control relay Contactors DC to AC INVERTER Fuses Surge protection devices Switch disconnectors Fuse holders

Products and solutions for photovoltaic applications 1000VDC... 4 Excellent design features have allowed the rated operational voltage upgrade of these switch disconnectors to 1000VDC in DC21 class, a characteristic increasingly in demand for modern photovoltaic systems. Fuse holders and fuses 1000VDC... 6 Fuse holders and fuses for the photovoltaic sector, designed to protect strings with up to 32A current and 1000VDC operational voltage rating. Voltage and frequency control relay... 7 A single voltage and frequency protection for single and three phase cogeneration systems, also equipped with ROCOF (Rate Of Change Of Frequency) function. Contactors A range including three and four pole versions, up to 1600A in AC1 duty, with AC and DC coil. Measuring instruments Digital multimeters and power analyzers, expandable, with graphic LCD, in addition to digital voltmeters, ammeters, wattmeters, frequency meters, power factor meters form a complete range of measuring instruments for comprehensive control of the AC side of a photovoltaic system (inverter output, delivery point and load connection). Energy meters Single-phase types up to 63A, three-phase model with direct connection up to 63A or by current transformer and a data concentrator. Among the best on the market also because of the compact size, function expandability and a selection of monitored measurements. MID certified versions, per EU Directive 2004/22/EC, also avalable. Current transformers Ranging from 40A to 400A primiary current and 5A secondary; solid and split core versions available. Switching power supplies Suitable for single, two and three phase systems. 12V and 24V output, modular and DIN rail mount versions available. 3

Products and solutions for photovoltaic applications GA series GAX42...D GAX60... Configuration 4 GAX42 040D GAX42 040D GAX60 00 GA080 D - GA080 D GAX42 080D / GAX42 125D GAX42 040D GAX60 00 GAX42 080D / GAX42 125D GAX60 01 GAX60 01 GAX42 080D / GAX42 125D Order Conventional Rated operational Qty Wt code free air current Ie per thermal current Ith DC21B (800V) Poles in series 4 p 6 p 8 p [A] [A] [A] [A] n [kg] Direct operating version, complete with black handle. 40 15 25 35 1 0.135 GA080 D 80 18 35 50 1 0.355 125 20 40 60 1 0.355 Fourth pole, simultaneous closing operation as switch poles. GAX42 040D 40 1 0.040 GAX42 080D 80 1 0.110 GAX42 125D 125 1 0.110 Mechanical coupling system for 6-8 pole switch disconnectors. GAX60 00 For. 1 0.050 5mm. GAX60 01 For GA080 D and. 1 0.075 7mm. UTILISATION IN DC21B CATEGORY Operational Maximum operational current voltage Ue in a configuration with: [V] [A] [A] [A] 2 POLES IN SERIES. Products to GA080 D fit together 300 16 20 25 3 POLES IN SERIES. Products to GA080 D fit together 48 40 80 125 110 35 70 120 220 32 40 95 500 12 15 20 4 POLES IN SERIES. Products to + GA080 D + + fit together GAX42 040D GAX42 080D GAX42 125D 400 35 40 64 440 32 40 64 500 32 40 56 600 20 30 40 700 15 18 20 750 15 18 20 800 15 18 20 6 POLES IN SERIES. Products to + GA080 D + + fit together + GA080 D + + GAX60 00 GAX60 01 GAX60 01 600 35 45 50 700 30 35 40 750 25 35 40 800 25 35 40 1000 10 20 25 8 POLES IN SERIES. Products to + GA080 D + + fit together + GA080 D + + GAX42040D+ GAX42080D+ GAX42125D+ GAX42040D+ GAX42080D+ GAX42125D+ GAX60 00 GAX60 01 GAX60 01 700 40 60 80 750 35 50 60 800 35 50 60 1000 25 32 40 General characteristics 40A to 125A ratings Available versions: direct operating door coupling version. Use switch disconnector with direct actuator and separately order the handle and shaft extension for this version. Screw or 35mm DIN (IEC/EN 60715) rail fixing Padlockable in 0 position with no extra accessory Available accessories : auxiliary contacts with simultaneous closing as switch disconnector poles auxiliary contacts with early-make closing respect to switch disconnector poles eartch and neutral terminals single and three-pole terminal covers shaft extensions for door-coupling handles up to 500mm long door-coupling handles with screw and ring fixing. Rated insulation voltage Ui: 1000V Rated impulse withstand Uimp: 8kV Mechanical life: 100,000 cycles for 30,000 cycles for GA080 D and. Certifications and compliance Certifications obtained: culus (to UL508/CSA C22.2 n 14 for, GAX42 040D and GAX60 00; to UL98/CSA C22.2 n 4 for GA080 D,, GAX42 080D, GAX42 125D and GAX60 01); GOST. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3, UL508, UL98, CSA C22.2. DIMENSIONS [mm] 36 22 Mechanical coupling system GAX60 00 72 GAX60 00 74 78 78 Mechanical coupling system GAX60 01 GAX60 01 140 70 43.9 GA080 D - GA0125 D 70 38.2 5 Fourth pole GAX42 040D 12 78 43.6 94 100 32.5 45 14.2 70 5 43.9 89 100 45 41.9 14.4 27 45 89 27 Fourth pole GAX42 080D - GAX42 125D 23 100 48.6 45

Products and solutions for photovoltaic applications GE series GE...DT4 GE... DT4P Direct operating handle GEX6 5D-GEX6 8D Order Conventional Rated Qty Wt code free air operational per thermal current Ie current DC21B❶ Ith (220V) (800V) [A] [A] [A] n [kg] Version for photovoltaic applications. Separately order the handle and shaft extension. GE0160 DT4P❷ 160 160 50 1 1.000 GE0160 DT4 160 160 50 1 1.000 GE0250 DT4 250 250 250 1 2.000 GE0315 DT4 315 315 280 1 4.000 GE0630 DT4 630 630 350 1 4.500 GE0800 DT4 800 800 630 1 4.500 GE1250 DT4 1250 1250 1000 1 8.900 ❶ Connection of four poles in series. ❷ Standard supplied with IP20 terminal protection. Order Characteristics Qty Wt code per n [kg] DIRECT OPERATING HANDLE, PADLOCKABLE. Rotating type with screw fixing on switch disconnector. Complete with shaft insert. GEX6 5D 50mm black lever 1 0.054 GEX6 6D 105mm black lever 1 0.216 GEX6 7D 245mm black lever 1 0.322 GEX6 8D 285mm black two-hand lever 1 0.328 General characteristics 160A to 1250A ratings Available versions: direct operating door coupling. Use switch disconnector with direct operation and separately order the handle and shaft extension. Screw fixing; 35mm DIN rail mount adapter kit for GE0160 DT4P Padlockable at 0 position with no extra accessory Available accessories: auxiliary contacts terminal covers 35mm DIN rail adapter kit for GE0160 DT4P shaft extensions for door-coupling handles up to 600mm long door-coupling handle with screw fixing. Rated insulation voltage Ui: 1000V Rated impulse withstand Uimp: 8kV for GE0160 DT4, GE0160 DT4P, GE0250 DT4, GE0315 DT4 12kV for GE0630 DT4, GE0800 DT4, GE1250 DT4 Mechanical life: 30,000 cycles for GE0160 DT4, GE0160 DT4P 20,000 cycles for GE0250 DT4, GE0315 DT4 10,000 cycles for GE0630 DT4, GE0800 DT4, GE1250 DT4. Certifications and compliance Certifications obtained: GOST. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3. Configuration DC21B CATEGORY UTILISATION Product to Operational voltage Ue order and 48V 110V 220V 400V 440V 500V wire Maximum operational current [A] [A] [A] [A] [A] [A] 4 POLES IN SERIES. GE0160 DT4P 160 160 160 105 90 85 GE0160 DT4 160 160 160 105 90 85 GE0250 DT4 250 250 250 250 250 250 GE0315 DT4 315 315 315 315 315 315 GE0630 DT4 630 630 630 630 630 630 GE0800 DT4 800 800 800 800 750 700 GE1250 DT4 1250 1250 1250 1250 1250 1250 Product to Operational voltage Ue order and 600V 750V 800V 850V 900V 1000V wire Maximum operational current [A] [A] [A] [A] [A] [A] 4 POLES IN SERIES. GE0160 DT4P 65 55 50 45 40 30 GE0160 DT4 65 55 50 45 40 30 GE0250 DT4 250 250 250 240 220 200 GE0315 DT4 315 290 280 270 260 250 GE0630 DT4 500 400 350 320 300 270 GE0800 DT4 700 650 630 580 550 500 GE1250 DT4 1250 1050 1000 940 870 850 5

Fuse holders Products and solutions for photovoltaic applications Fuse holders FB01 D... FB01 D 1PL Order Pole Status DIN Qty Wt code configu- light size per ration n n [kg] Fuse holders for 10x38 fuse. 32A rated current In at 1000VDC. FB01 D 1P 1P 1 12 0.064 FB01 D 1PL 1P YES 1 12 0.065 FB01 D 2P 2P 2 6 0.127 FB01 D 2PL 2P YES 2 6 0.130 Rated voltage Ue: 1000VDC Rated current Ie: 32A Utilisation category: DC20B 1000VDC Suitable for fuse class: gpv Degree of protection: IP20. Reference standards Compliant with standards: IEC/EN 60269-1, IEC/EN 60269-2, IEC/EN 60947-1, IEC/EN 60947-3. Fuses FE01 D... Order Rated current Qty Wt code In per [A] n [kg] Fuse,10x38 size. 30kA rated breaking capacity at 1000VDC. FE01 D 00200 2 10 0.008 FE01 D 00400 4 10 0.008 FE01 D 00600 6 10 0.008 FE01 D 00800 8 10 0.008 FE01 D 01000 10 10 0.008 FE01 D 01200 12 10 0.008 FE01 D 01600 16 10 0.008 FE01 D 02000 20 10 0.008 Rated voltage Ue: 1000VDC Rated current Ie: 2-20A Utilisation category: DC20B 1000VDC Fuse class: gpv. Conformità Conformi alle norme: IEC/EN 60269-6. 10000 2A 4A 6A 8A 10A 12A 16A 20A 1000 100 PREARCING TIME (sec) 10 1 0.1 0.01 0.001 1 10 100 1000 PROSPECTIVE CURRENT (A) Accessories FBX 00 Order Description Qty Wt code per [A] n [kg] FBX 00 Coupling clip for 100 0.003 10x38 fuse holders FBX 01 Coupling pin for 100 0.005 10x38 fuse holders FBX 00 FB01 D... FBX 01 FBX 01 FB01 D... 6

Voltage and frequency control relay Products and solutions for photovoltaic applications Voltage and frequency monitoring PMVF10 Order code Rated voltage to be Qty Wt controlled Ue per [V] n [kg] Three-phase low-voltage system, with or without neutral. Compatible for single-phase low-voltage system. Minimum and maximum AC voltage and frequency plus ROCOF. PMVF10 230/400VAC 1 0.254 50Hz Status indication table Anomaly Green LED Red LED Red LED Red LED Relay output ON Vmin Vmax Hz 1 and 2 None Constantly Switched Switched Switched Energised lighted off off off Min/max Flashing Switched Switched Constantly De-energised frequency off off lighted or ROCOF Voltage Flashing Constantly Switched Switched De-energised <Vmin lighted off off Voltage Flashing Switched Constantly Switched De-energised >Vmax off lighted off General characteristics The monitoring relay PMVF10 is designed and developed to satisfy requirements of the local power authority (ENEL guide edition 2.1 of 12/2010). The authority imposes that the following automatic controls be done whenever an independent power source (e.g. wind turbine or photovoltaic systems, diesel generating set, etc.) is connected in parallel with the electrical grid (local low-voltage utility): Limits of minimum and maximum voltage values Limits of minimum and maximum frequency values Limit of the Rate Of Change Of Frequency (ROCOF). When at least one of these limits are not respected, abnormal conditions need to be signalled using a contact. Typically, the contact is used to isolate the independent power source from the electrical grid. The following protections are available: Maximum voltage Minimum voltage Maximum frequency Minimum frequency ROCOF. TRMS (True-rms) measurements of this relay allow to obtain a correct operation even in presence of harmonic voltages. The device has fixed tripping thresholds for minimum and maximum voltage while those for frequency can be selected between two predefined values using a rotary switch. A reset delay is adjustable by potentiometer. Self powered by the system to control Compatible for: Three-phase systems (400VAC 50Hz), with or without neutral Single-phase systems (230VAC 50Hz) TRMS measurements 2 relay outputs, each with one changeover contact, rated 8A 250VAC in AC1 Modular DIN 43880 housing (3 module) Degree of protection: IP40 on front (only when mounted in housing or electric board with IP40); IP20 on terminals. PROTECTIONS For maximum voltage: Threshold 1.13Ue (fixed) Tripping time 0.1s (fixed). For minimum voltage: Threshold 0.825Ue (fixed) Tripping time 0.2s (fixed). ADJUSTMENTS Mode Reset delay Multifunction rotary switch: Control of phase or phase-to-phase voltage values Frequency threshold ±0.3 or ±1Hz ROCOF (>0.5Hz/s) ON-OFF. Resetting time 0.1-30s. STATUS INDICATIONS 1 green LED for system within limits (flashing when out of limits) 3 red LEDs for minimum and maximum voltage, minimum and maximum frequency and ROCOF. Certifications and compliance Certifications obtained: local power authority (ENEL Guide, edition 2.1 10/2010). Compliant with standards: IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 610006-3. 7

The products described in this publication are subject to be revised or improved at any moment. Catalogue descriptions and details, such as technical and operational data, drawings, diagrams and instructions, etc., do not have any contractual value. In addition, products should be installed and used by qualified personnel and in compliance with the regulations in force for electrical systems in order to avoid damages and safety hazards. www.lovatoelectric.com LOVATO ELECTRIC S.P.A. CONTROL SOLUTIONS FOR INDUSTRY Present in over 100 countries VIA DON E. MAZZA, 12-24020 GORLE (BERGAMO) ITALY Tel. +39 035 4282111 Fax +39 035 4282200 E-mail: info@lovatoelectric.com Sales department: Tel. +39 035 4282354 - Fax +39 035 4282400 LOVATO Electric offices in the world United Kingdom LOVATO ELECTRIC LTD Tel. +44 8458 110023 www.lovato.co.uk Czech Republic LOVATO SPOL. S.R.O. Tel. +420 226 203203 www.lovatoelectric.cz Germany DELTEC LOVATO GmbH Tel. +49 7237 1733 www.lovatoelectric.de USA LOVATO ELECTRIC INC Tel. +1 757 545 4700 www.lovatousa.com Spain LOVATO ELECTRIC S.L.U. Tel. +34 93 7812016 www.lovatoelectric.es Canada LOVATO ELECTRIC CORPORATION Tel. +1 450 681 9200 www.lovato.ca PD75 GB 11 11 Poland LOVATO ELECTRIC SP. Z O.O. Tel. +48 71 7979010 www.lovatoelectric.pl Mexico LOVATO ELECTRIC DE MEXICO, S.A. DE C.V. Tel. +52 555 3415662 www.lovatoelectric.com.mx