Grout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram

Similar documents
Cruise Control Wiring

BATTERY DISCONNECT SERVICE MANUAL

Troubleshooting Bosch Proportional Valves

Servo and Proportional Valves

Service Manual for Battery Control Center

Corsa Performance Marine Solenoid & Harness Testing Procedures

ELECTRONICS & HWH 19APR11

Section 6. Electrical System

Starter, Delco Remy 15.01

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

HWH Online Technical School Lesson 10: Air Suspension and HWH (Filename: ML DOC Revised: 23APR16) Click Here for Printable PDF File

Ebling Back Blade Snow Plow Wireless Controller Kit Only sold by SnowplowsPlus.com and ControlAllWireless.com

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

Water to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480

PARTS AND SERVICE MANUAL FOR LEVELING SYSTEMS WITH TOUCH PAD PART NUMBERS , , , , or no number at all

OCTOPUS SELECTION & INSTALLATION GUIDE

ELECTRICAL. Contents - Wiring Diagrams

ALTERNATOR PRECAUTIONS. Some precautions should be taken when working on this, or any other, AC charging system.

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

Photo below shows the yellow wire on the left and the black on the right.

Section 7.1. Wheel Drive Circuit - General System

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

Technical Information and Diagnostic Guide

Click Here for Printable PDF File

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

ELECTRICITY AND HWH COPPER CONDUCTOR

SK1001 SPEED KIT For 48-volt Club Car DS Model Installation Instructions

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

Shaved-B. Installation Manual & Operation Instructions

Phone: Fax: ILD Series. Troubleshooting: ILD Column Lift

DIAGNOSTIC TROUBLESHOOTING INDEX

Hydro-Sync Slide-Out System

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Troubleshooting Guide

OCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET

50 1/50 2 Directional Contactor Installation

KWIKEE #888 ELECTRIC STEP. Owner's Manual ( )

Troubleshooting Guide

TROUBLESHOOTING GUIDE

Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch

oubleshooting Guide diesel - gasoline - LPG electric P.O. Box 1160 St. Joseph, MO Fax:

PAGE Both power cords must be connected & powered to operate the E-TES 120.

Irrigation Components International, Inc.

Computers and Control Systems: Symptom Related Diagnostic Procedures C Charts. Part 1 of 6. Chart C-1 (1 Of 6)

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

Ch 4 Motor Control Devices

2. Milk does not heat and the heater is not hot. a. Is there power getting to the pasteurizer heater? Check the incoming voltage to the contactor

POWERLINE 2000 Energy Management System TM

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual

Smart Switch Basic Kit - 24 volt ( ) Wiring Instructions

CONTROLLER DIAGNOSTIC GUIDE

6500DC Dual Motor Wireless Controller Kits

REPAIR MANUAL ZT2452A

WALKIE HIGH LIFT HYDRAULIC SYSTEM

Compact Triple Electric Step OWNERS MANUAL

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

INSTALLATION MANUAL. Middle. Def tank. Standard. Middle. Standard. Def tank WARNING. Level of Difficulty CAUTION. Parts List.

Deluxe High Amp Switch Kit - 12 Volt Wiring Instructions

INFORMATION TROUBLESHOOTING GUIDE AND FOR MONARCH D.C. POWER UNITS ON SNO-WAY PLOWS

REPAIR MANUAL HWH COMPUTER-CONTROLLED HYDRAULIC LEVELING SYSTEM 400 SERIES FEATURING: PADDLE SWITCH CONTROL AUTOMATIC LEVELING VERTICAL

Solenoid - Troubleshooting Guide

Hydraulics Troubleshooting

B U L L E T I N. Application Engineering AE R1. February Sentronic + Electronic Oil Pressure Control. Reformatted October 2010

3094PM1ii (Model VS-24-11) & 3094PM4ii (Model VS-24-9)

DISCUSSION OF FUNDAMENTALS. A hydraulic system can be controlled either manually or automatically:

Troubleshooting Guide


WARRANTY WILL BE VOID If These Steps are Not Performed Before Installing The Control STEPS TO PERFORM BEFORE CONTROL INSTALLATION

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

Warranty Approval. Visual Inspection of Starters & Alternators

SHAVED-DX. Installation Manual & Operation Instructions. Trouble Shooting Reverse Polarity Wiring Problems

Advanced EasyStart Troubleshooting

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Stir-Guard Operation. Instructions Design III Stir-Guard Option

For system diagrams and component identification

th Street, Surrey, B.C. Canada V3W 0A6 Telephone Fax July 2012

Read Chapter 8 Servicing Machine in the Manual for general guidelines

RODIX, INC. FC-40-PLC Plus Series Control Troubleshooting Guide for Circuit Board P/Ns and

Tattletale Annunciators and Magnetic Switches

Automotive Parts. Charging & Starting Systems

750 Paso Wiring Upgrade

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

POOL PILOT SOFT TOUCH OPERATING, TROUBLESHOOTING AND TECHNICAL CHEAT SHEET

Electric/Battery Pump

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Constant Speed Control

USER MANUAL PRODUCTION LINE TESTER PLT600

Technical Information and Diagnostic Guide RestStar Use this guide with 5700XE RestStar Unit. Western Star 5700XE.

PCS HIGH-LOW TIMER CONTROLLER USER GUIDE PCS HIGH-LOW TIMER CONTROLLER. Contents. Calibrating the Transducer... 6

APOLLO Gate Operators, Inc.

PARTS AND SERVICE MANUAL for DEWALD HYDRAULIC SLIDE OUT SYSTEMS

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

Typical Marinette AC Wiring

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

Controls Manual Standard 1 Fan Control Panel

We Make It Easy! 3. All of our switches are shipped complete, just as ordered. No incomplete or partial deliveries of subcomponents and accessories

Transcription:

Grout Pump Automatic & Manual Troubleshooting 40-500 Gas Wiring Diagram Turn engine off and relieve hydraulic pressure and grout pressure before troubleshooting. Note: Typically there is a wiring diagram on the gray Geo-Loop electric box inside the cover. If not we can e-mail you a copy to help troubleshoot your problem. These are wires pertaining to operation of grout pump manual and auto switches. First let s talk through the circuit that typically will fix the problem, if the grout pump electric troubleshooting guide will not fix the problem. Starting with 12 volt DC from the grout pump fuse, red 14 gauge wire power supply to both toggle switches. (1) Grout pump manual switch has jumper wire from center terminal over to grout pump auto switch (either terminal). Grout pump auto toggle switch (black wire, load side of switch) powers the common terminal on the ratchet relay (3) located in the gray Geo-Loop electric box and two blue wires (5) going to the micro switches on the grout cylinders. (1) Red 14 gauge wire power supply from grout fuse Keyed power 10 amp fuse Red wire grout pump 15 amp fuse (3) Ratchet Relay Com (5) From grout pump auto single pole single throw toggle switch load side Note: old style micro switches use a black wire (see 8B diagram on page 2). Oil cooler fan 15 amp fuse Power in from battery 30 amp fuse 1

New style micro switch with weather resistant plug, blue and brown wire (see picture below). 8 Old style micro switch, black and white wire (see picture below). Use N.O. 1 com and N.O. 3 terminals only. 8B 2

(9) 2 brown wires from grout cylinder micro switch to ratchet relay coil 18 20 (12) Ground Lug (16) Plastic rocker (14) Ratchet relay coil plunger (9) The two brown wires returning from the micro switch (white on older models, pre 2011) go to power the coil on the ratchet relay. The green wire on the ratchet relay coil goes to the ground (12). These two terminals are not polarity sensitive. (8) The micro switch on the grout cylinder (page 2) is a momentary contact, normally open, switch that sends power to the coil from the brown wire on the ratchet relay when in contact with the grout piston. This pulls the plunger (14) up inside of the coil and moves the white plastic rocker (16) to one side or the other causing power to be sent to either the black wire N.C. 2 terminal (20) or the red wire N.O. 3 (18) terminal and out of electric box through 14-2 cable down to either coil attached to hydraulic solenoid valve (32). Please note that the ratchet relay coil plunger must fully extend back down with the help of the spring on each cycle. If the plunger does not retract, one of the two micro switches on the grout cylinder may be stuck in the on (or closed) position not allowing pump to reverse direction or dirt-dust contamination will cause it to stick also. The box cover must be in place to prevent electrical component damage. 3

If the grout pump micro switches and ratchet relay all tests good, then test the two coils on the hydraulic solenoid valve (32). With grout pump auto switch turned off, engine off and all hydraulic and grout pressure relieved. Using a steel object such as a screw driver, hold above the coil to check for magnetism (30). Each of the two coil nuts will become magnetized one at a time by moving the grout pump manual switch back and forth. If one of the coils fail to magnetize check the 2, ¼ spade connectors on the coil (32), clean and use a corrosion protector on connections. Test with a volt meter to be sure you have a minimum of 12 volt DC power or using an OHM meter, check the continuity through the coil. (36) Coil nut (31) Hydraulic solenoid coil (32) ¼ spade connectors (30) Check magnetism here on coil nut or top of pilot valve cartridge (34) Pilot valve cartridge (32) ¼ spade connectors (31) Hydraulic solenoid coil (34) 1 end wrench required to remove cartridge 4

If you have a full 12 volt DC power to coil and a good ground on white and green wires in gray electric box copper ground lug, and it does not magnetize, replace coil. If the coils test good and magnetize one at a time, by moving grout pump manual 3 position switch up or down, then move on to the last step that very seldom ever fails. The pilot valve in the hydraulic solenoid valve may be bad if the pump sticks to one side and will not move. Shut off engine and relieve all pressure on hydraulic system, grout pump and grout line. Take a ¾ end wrench and remove the coil nut (36). Then using a 1 box end wrench remove the pilot valves (34) on both ends of the solenoid valve and swap end to end. Replace the coils, cleaning the shaft properly and apply never seize or grease. Do not over tighten the nut that holds the coil in place, 60 in lbs. or 5 ft. lbs. torque. If the grout pump piston now travels to the opposite end and sticks we now have diagnosed a bad pilot valve. Replace as needed. 5