String Sizing with SkyBox

Similar documents
How To Set Up SimpliPhi Batteries Using OutBack Chargers

FLEXnet DC Programming & Guidelines

How To AC Couple Grid Tied Inverters with OutBack Frequency Shifting Inverters

FW-IOB-T-120/208VAC Input/Output/Bypass Assembly. Installation Instructions

Using OutBack Inverters for 3-Phase 480V Applications

Using Inverter Input Modes for Smart Grid Management

EnergyCell FLA Series. Owner s Manual

Preventing Grid Sell-Back When AC Coupling

User s Guide. Includes Mounting, Installation, and Product Registration

Current Automation Catalogue Page 27

GS-IOB-230VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

GS-IOB-120/240VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

OFF GRID PV POWER SYSTEMS SYSTEM DESIGN GUIDELINES FOR THE PACIFIC ISLANDS

User s Guide Includes Mounting, Installation, and Product Registration

APPLICATION NOTE. Conext Solar Charge Controllers: Ground Fault Protection. Document Number: AU-1.0. Exclusion for Documentation.

FLEXmax Series Charge Controllers. (FLEXmax 80, FLEXmax 60) Owner s Manual

SimpliPhi Power PHI Battery

OFF GRID Solar system

SimpliPhi Power PHI Battery INTEGRATION GUIDE: OUTBACK POWER. Power. On Your Terms.

make, store, manage w i t h

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

AC Coupling Grid Tie Inverters With OutBack Battery-Based Inverters

Ningbo Star Solar Co.,Ltd Tel:(86) Fax:(86)

Photovoltaics. MPI Hybrid Series

idealpv SSP1 220/270 Solar Panel

MICROINVERTER ANALYSIS

CC 2000 Controller. Accommodates Arrays with two to twelve 36-cell Modules in Series; Will Operate from 24 to 144 volt Battery Banks

Schneider Electric Conext SW

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

On-grid or off: We carry the load

Power Back Up Product Announcement

CLASSIC MPPT CHARGE CONTROLLERS

Ag Features. Multi-Stage Charging. Solar Panel or DC Input. Maximum Power Point Tracking (MPPT) Very Low Power Consumption

Off Grid Cabin Special Pkg 1-170W PV

WITH TRAKSTAR TM MPPT TECHNOLOGY. Installation and Operation Manual. Model: SS-MPPT-15L

The Traveler Series: Adventurer

INTEGRATED RENEWABLE ENERGY SYSTEMS

Why Is My PV Module Rating Larger Than My Inverter Rating?

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

Wind Energy System.

AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-3640-LED-185-T

the National PhotoVoltaic protection note 5 I rated Introduction points of interest When to Fuse, When Not to Fuse

Xantrex XW System The NEW Standard

Get More When Shopping for Solar

Azure Micro-Grid Village Power Systems

The Traveler Series TM : Adventurer

INTEGRATED RENEWABLE ENERGY SYSTEMS

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Magnum AC Coupled In a D3R battery box MND3RACCPLME 7/20/18

200W Solar Charger Maximum Power Point Tracker

MNPV2, MNPV3, MNPV4, MNPV6 Instructions

MPPT75HV MAXIMUM POWER POINT TRACKING SOLAR BATTERY CHARGE CONTROLLER

Designing Stand Alone Systems. Overview, components and function, Elements in Design

672W Off Grid Residential Package

Using the Phoenix MultiPlus to reduce operating cost of a generator

Figure 1b: Daily Production Profile Non Power Limiting Day

Solar inverter AX-series

Using Inverter Input Modes for Smart Grid Management

Application. Battery. Public Grid GS HYBRID INVERTER

System Advisor Model (SAM) SimpliPhi Power Battery Modeling Instructions

ISES Solar Charging Station

AERL RACEMAX MAXIMIZER User's Manual

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection

R series solar charger inverter 1000W to 6000W

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

SMART 1000 / 2000 SERIES

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

EnergyCell Battery. Owner s Manual

Xantrex XW System Quick Start Guide to Purchasing

Motion Controlled Lighting Using with Phocos CIS Family Charge Controllers and LED Drivers

First Responder System Identification Quiz. Presented by the NY-SUN PV Trainers Network

User Manual HomeGrid 5000 HD

Initial Project and Group Identification Document. Senior Design I EEL Off-Grid Clean Energy Power Generation

FLEXmax Extreme Charge Controller

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

Code Calculations. for an Off-Grid PV System

1700W Solar Battery Charger Maximum Power Point Tracker

Description Sets the priority for the AC source (AC1 or AC2) for qualification and transfer.

Solar Charging Station for Education and Research

Faster charging with solar power even during AC mains outage MPPT* controller to maximize solar energy harvest(3k/5k) Clear charging status on LCD

3400W Solar Battery Charger Maximum Power Point Tracker

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Power Management Chip. Anthony Kanago Valerie Barry Benjamin Sprague John Sandmeyer

Module-Integrated Power Electronics for Solar Photovoltaics. Robert Pilawa-Podgurski Power Affiliates Program 33rd Annual Review Friday, May 4th 2012

off-grid Solutions Security of supply Basics: Off-grid energy supply

OPTI-Solar SC MPPT Series

230VAC Power Inverter 400W Owner s Manual

Clipper Instructions

P-Box. Pre-Assembled Off-Grid Power Cabinets. All-in-One Power Cabinet for Off-Grid Solar Power Systems

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

MX60. PV MPPT Charge Controller. Please read this entire manual prior to installing and using the MX60.

DANGER. The Conext products below can utilize Load Shedding and Load Shifting:

Airpax Dimensions, Inc.

Plug Into the Current Future

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

Plug Into the Current Future

Combi Series Interactive Inverter-Chargers

Solar PV Standard Electrical Plan

Solardyne Corporation Renewable Home Power Design Guide Call

Transcription:

String Sizing with SkyBox Sizing a solar array is based on many variables. The calculation steps involved are shown below as well as an example using the OutBack SkyBox. Variables not taken into account over these examples include shading coefficients and panel angles. The traditional method for string sizing with OutBack charge controllers no longer applies to the SkyBox product. The FLEXmax products are centered on the battery, so many calculations include a nominal battery voltage. The SkyBox is not centered on the battery and supports PV strings between 250 Vdc and 600 Vdc, so the calculations presented here are different from those presented in earlier application notes for OutBack products. Procedure 1. Gather appropriate data 2. Correct for coldest temperature 3. Correct for highest temperature 4. Calculate maximum and minimum panel configurations 5. Calculate maximum power Step 1: Gather appropriate data The data required can be found on the specification sheet for the chosen panel (or potential panels) and the inverter specification sheet. Panel data: 1. Open circuit voltage (V oc ) 2. Short circuit current (I sc ) 3. Maximum power voltage (V mp ) 4. Thermal coefficients (α oc, α mp ) SkyBox data: 1. Maximum input voltage 2. Minimum input voltage 3. Maximum input current Step 2: Correcting for the Coldest Expected Temperature,, 1, 1 Where: 25 2 The formula shown above can be used to calculate the maximum voltage experienced by the SkyBox due to cold temperatures. Dependent upon the application, T cold can be the record low temperature, to fail conservatively, or the average low temperature for the area. 2018 OutBack Power Technologies, Arlington, WA 98223 FA KF 11/09/18 1 of 6

All temperatures must be in degrees Celsius. The formula below can be used to convert Fahrenheit to Celsius. 5 9 32 3 Step 3: Correcting for the Warmest Expected Temperature Correcting for the warmest expected temperature ensures the array will not decrease below the minimum operating PV voltage for the SkyBox.,, 1, 4 Where: 25 5 The formula shown above can be used to calculate the minimum voltage experienced due to warm temperatures. The temperatures used in this formula must be in degrees Celsius. Step 4: Maximum and Minimum Panels in Series Once the V oc, max and V mp,min values are calculated, the maximum and minimum number of panels in series can be calculated. The maximum inverter input voltage divided by the V oc, max gives the maximum number of panels connected in series that will not exceed the inverter voltage rating. If a SkyBox detects it is connected to an array producing more than 600 Vdc, it will keep its PV relay open until the voltage falls into the operating range. Dividing the minimum operating PV voltage by the V mp, min will give the minimum panels needed to operate above the lower voltage limit. Step 5: Maximize Array Power 6 The SkyBox supports any array from 250 to 600 V oc and 20 Adc. It will produce up to 5000 W of DC power from PV. Using this number and the maximum power calculated above, the ideal number of panels can be calculated. More panels can be added to an array in order to increase the available power. However, the SkyBox will only produce up to 5000 W, even if more power is available. Once the optimum number of panels is known, the configuration can be chosen. 5000 7 2018 OutBack Power Technologies, Arlington, WA 98223 FA KF 11/09/18 2 of 6

Example Step 1: Gather data Name Example300 STC Watts 300 V oc 40.0 V mp 31.6 I mp 9.57 α T,oc ( -1 ) 0.29% α T,mp ( -1 ) 0.39% Name Max I mp Max Input Voltage Min Input Voltage Maximum DC Power Output SkyBox 20 Adc 600 Vdc 250 Vdc 5000 W Step 2: Correct for Coldest Expected Temperature Location: Arlington, WA Extreme Minimum: 9 C 9 25 34, 40.0 1 0.0029/ 34, 40 1 0.0986, 43.94 Step 3: Correct for Warmest Expected Temperature 2% Average High: 27 C Equation (5) is used to find the difference between the standard test temperature (25 C) and the local panel temperature. 10 C is added to account for an increase in temperature on the rooftop where panels will be located. Equation (4) is used to find the minimum voltage expected. 27 25 10 12 2018 OutBack Power Technologies, Arlington, WA 98223 FA KF 11/09/18 3 of 6

, 31.6 1 0.0039 12, 32.6 1 0.0468, 30.12 Step 4: Calculate Maximum and Minimum Panel Configuration #, 600, #, 600 43.94 #, 13.65 A system cannot have a fraction of a panel. To avoid exceeding the voltage rating of the SkyBox, a maximum of 13 panels in series may be used. #, 250, #, 250 30.12 #, 8.3 To avoid falling below the lower voltage limit, a minimum of nine panels must be used. Step 5: Maximize array power Solution: 9.57 31.6 302.4 5000 302.4 16.5 A system in Arlington, WA operating under ideal conditions will produce 5000 W with two strings of nine panels each. The PV array can be oversized in order to compensate for non-ideal conditions. These strings can range anywhere between nine and thirteen panels (the minimum and maximum number calculated above). An array in any of these configurations will not exceed the ratings of the SkyBox MPPT. 2018 OutBack Power Technologies, Arlington, WA 98223 FA KF 11/09/18 4 of 6

Conclusion In this application note, the procedure was outlined to accurately size PV arrays to the abilities of the SkyBox. These steps differ from the battery-centric method used previously with the FLEXmax charge controllers. After sizing the appropriate battery bank (if applicable), and using the examples above, sizing the PV array with the SkyBox is a simple task. 2018 OutBack Power Technologies, Arlington, WA 98223 FA KF 11/09/18 5 of 6

About OutBack Power Technologies OutBack Power Technologies is a leader in advanced energy conversion technology. OutBack products include true sine wave inverter/chargers, maximum power point tracking charge controllers, and system communication components, as well as circuit breakers, batteries, accessories, and assembled systems. Contact Information Address: Website: Other Corporate Headquarters 17825 59th Avenue N.E. Suite B Arlington, WA 98223 USA http://www.outbackpower.com OutBack Power Technologies assumes no responsibility or liability for loss or damage, whether direct, indirect, consequential or incidental, which might arise out of the use of this information. Use of this information is entirely at the user s risk. OutBack Power Technologies cannot be responsible for system failure, damages, or injury resulting from improper installation of their products. Information included in this document is subject to change without notice. 2018 by OutBack Power Technologies. All Rights Reserved. 2018 OutBack Power Technologies, Arlington, WA 98223 FA KF 11/09/18 6 of 6