ALTERNATE COMPLIANCE PROGRAM

Similar documents
AIR LUBRICATION SYSTEM INSTALLATION

RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSIONS CHAPTERS APPROACH

HAZARDOUS AREA CLASSIFICATION (APPLICATION OF SOLAS REGULATION II-1/45.11)

Section 4 SURVEYS SPECIAL SHIP TYPES

BSS Examination Record Form for Privately Owned and Managed Vessels

CHAPTER II-1 D. Construction subdivision and stability, machinery and electrical installations

MSC Guidelines for Fired Thermal Fluid Heaters Procedure Number: E1-28 Revision Date: April 20, 2018

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

United Stales COMDPTPUB P Coast Guard NVIC Mar 191

ICOMIA Global Conformity Guideline for ISO and ABYC Standards. Guideline Number 8 Ventilation of fuel systems

Sector Baltimore Small Passenger Vessel Branch Initial Certificate of Inspection (ICOI) Work Instruction

ST. VINCENT AND THE GRENADINES

PART 8 MACHINERY INSTALLATIONS

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

MSC Guidelines for Fired Thermal Fluid Heaters Procedure Number: E1-28 Revision Date: 06/11/2014

M-22 DUAL FUEL ENGINE

CHAPTER II-1 C. Construction subdivision and stability, machinery and electrical installations

MSC Guidelines for Electrical Plans Small Passenger Vessels

Form of IOPP Certificate and Supplements * INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES. Comments on document FP 46/5/8. Submitted by Japan

RULES FOR CLASSIFICATION Yachts. Part 4 Systems and components Chapter 6 Piping systems. Edition December 2015 DNV GL AS

PART II RULE FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSION TITLE 31 SELECTION OF SHIP TYPE FOR LIQUID BULK CARGOES

RESOLUTION MEPC.205(62) Adopted on 15 July GUIDELINES AND SPECIFICATIONS FOR ADD-ON EQUIPMENT FOR UPGRADING RESOLUTION

GUIDELINES ON THE MEANS OF ACCESS TO STRUCTURES FOR INSPECTION AND MAINTENANCE OF OIL TANKERS AND BULK CARRIERS (SOLAS REGULATION XI-1/2)

HELICOPTER DECKS AND FACILITIES (HELIDK AND HELIDK(SRF)) APRIL 2008

E/ECE/324/Rev.2/Add.104/Rev.2/Amend.3 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2/Amend.3

MSC Guidelines for Fuel Oil Systems

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE. Level 3 Assessment Chief and Second Engineer <3000kW

RULES PUBLICATION NO. 98/P

GUIDELINES FOR PORT STATE CONTROL UNDER MARPOL ANNEX VI

KEEL MARINE LTD Naval Architects, Marine Engineers and Surveyors

Fully Automatic Bilge Pump INSTRUCTION MANUAL

RESOLUTION MEPC.181(59) Adopted on 17 July GUIDELINES FOR PORT STATE CONTROL UNDER THE REVISED MARPOL ANNEX VI

casualty information Dear Captain General Requirements Encl.: 7 pages

APPLICATION OF MARPOL 73/78 ANNEX VI TO EXISTING SHIPS

Ships in Operation Survey Requirements

ST. VINCENT AND THE GRENADINES

IMO REQUIREMENTS JULY 2018 TO MAY 2021

Annex-1: Summary of new IMO requirements from 1 January2017 Resolution New Ship Existing Ship Subject Remarks Ship type Size Compliance date

BPQ5 USA Offshore Tug Date updated date 2 Tug Name text 3 Identification. 5 Build 1 Date delivered (built) 2 Builder (where rebuilt)

ICOMIA Global Conformity Guideline for ISO and ABYC Standards. Guideline Number 1 Installed Fuel Systems and Fixed Fuel Tanks

RESOLUTION MEPC.266(68) (adopted on 15 May 2015) AMENDMENTS TO THE ANNEX OF THE INTERNATIONAL CONVENTION FOR THE PREVENTION OF POLLUTION FROM SHIPS,

INFORMATION BULLETIN No. 165

Australian Explosives Industry and Safety Group (AEISG) Code of Practice Mobile Processing Units 4 th edition. Compliance Checklist.

Gearless / full scantling cellular container vsl with poop, forecastle and open top cargo hold

INFORMATION BULLETIN No. 84

Report No.: Name of Ship: Plans referred during Initial Survey:

ANNEX 2 RESOLUTION MEPC.96(47) Adopted on 8 March 2002

2015 Printing, America s Boating Course 3 rd Edition (ABC3) Errata 11 June 2016 Updated 21 April 2017

Y-fl'. MINISTRY OF TRANSPORT AND COMMUNICATIONS DEPARTMENT OF MARINE ADMINISTRATION

ANNEX 8 RESOLUTION MEPC.102(48) Adopted on 11 October 2002 GUIDELINES FOR SURVEY AND CERTIFICATION OF ANTI-FOULING SYSTEMS ON SHIPS

ANNEX 23. RESOLUTION MEPC.187(59) Adopted on 17 July 2009

AMENDMENTS TO MARPOL ANNEX I AND CHANGES TO THE OIL RECORD BOOK PARTS I AND II

INFORMATION BULLETIN No. 165

MARPOL Annex I and Changes to the Oil Record Book Parts I and II.

RESOLUTION MEPC.182(59) Adopted on 17 July GUIDELINES FOR THE SAMPLING OF FUEL OIL FOR DETERMINATION OF COMPLIANCE WITH THE REVISED MARPOL

DEPARTMENT OF MARINE SERVICES AND MERCHANT SHIPPING (ADOMS) REGULATORY AMENDMENTS ENTERING INTO FORCE DURING JANUARY 2017

RESOLUTION MEPC.120(52) adopted on 15 October 2004 GUIDELINES FOR THE TRANSPORT OF VEGETABLE OILS IN DEEPTANKS OR IN INDEPENDENT TANKS SPECIALLY

Systems and Arrangement for Meeting Regulations in Emission Control Areas (ECA)

MACHINERY SYSTEMS, GENERAL

Part 6 Additional class notations Chapter 7 Environmental protection and pollution control

RO-PAX FERRY April 28 th, Gabriel, Shaun, Timothy

Lloyd s Register Type Approval System Test Specification Number GT04

IACS UR s and Panel Responsible

4Electrically propelled vessels

TP 11960E (01/2017) Standards for the Construction, Inspection, and Operation of Barges Carrying Oil or Dangerous Chemicals in Bulk

Outline Specification 60M -1500m 3 Live Fish Carrier

IACS Technical Resolutions adopted from July 2012 to December 2012

Efficient Risk Assessment for ships using Low Flash Point Fuel

Amendment of UN ECE R100 regarding in-use requirements for vehicles of category L Status:

ANNEX 32 RESOLUTION MEPC.139(53) Adopted on 22 July 2005

Subj: HYDROGEN AND IGNITION ENERGY HAZARDS IN PASSENGER SUBMERSIBLES

Examples of the application of Permanent Means of Access to Tankers

Annex II Requirements. What are noxious liquid substances?

NORTH AMERICAN ECA AND NEW FUEL SULFUR CONTENT REQUIREMENTS

Main changes in BV Rules for Steel Ships

NEWBUILDINGS MACHINERY AND SYSTEMS MAIN CLASS. Piping systems JULY 2015

Rules for Classification and Construction Ship Technology

Ventilation Blowers 09. Introduction Heavy Duty Radial Blowers Radial Blowers In-Line Blowers

RULES FOR THE CLASSIFICATION AND CONSTRUCTION OF SEA-GOING SHIPS

Part 4 Systems and components Chapter 1 Machinery systems, general

IACS UR s and Panel Responsible

INTERNATIONAL AIR POLLUTION PREVENTION CERTIFICATE. GOVERNMENTOFmELAND

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE. Level 3 assessment Marine Motorman Higher Grade

E/ECE/324/Rev.2/Add.106/Rev.6/Amend.5 E/ECE/TRANS/505/Rev.2/Add.106/Rev.6/Amend.5

National Marine Manufacturers Association

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

Guideline No.: E-03(201806) E-03 MOTORS. Issued date: June 7, China Classification Society

The SubChapter M Webinar Series

RESOLUTION A.747(18) adopted on 4 November 1993 APPLICATION OF TONNAGE MEASUREMENT OF SEGREGATED BALLAST TANKS IN OIL TANKERS

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT)

GASEOUS FUELS SAFETY ASPECTS

Not to be reproduced without permission Last date for receipt of BIS or used as STANDARD of comments 15 September 2011

Guidelines for Ships Using Alternative. Fuels

SPECIFICATION OFFICIAL NO BREADTH 15.1 GROSS TONNAGE 33 PASSENGERS US GALLONS

Part 6 Additional class notations Chapter 7 Environmental protection and pollution control

CIRCULAR IMO FAQ on the sulphur limits in Emission Control Areas (ECAs)

Radiation Safety Requirements for the Use of Non-Medical X- Ray.

SHOCK TESTING OF EQUIPMENT AND SYSTEMS NAVAL APPLICATIONS

Transcription:

ALTERNATE COMPLIANCE PROGRAM Addendum to US Supplement Rev. 1.0, approved November 21 st 2003 For Passenger Catamaran Vessels certificated or to be certificated under 46 CFR Subchapter H Lloyd s Register Rules and Regulations for the Classification of Special Service Craft, July 2003 ADDENDUM TO ANNEX to the MEMORANDUM OF AGREEMENT between the UNITED STATES COAST GUARD and LLOYD S REGISTER GOVERNING PARTICIPATION IN THE ALTERNATE COMPLIANCE PROGRAM AND THE DELEGATION OF CERTAIN SURVEY AND CERTIFICATION SERVICES FOR UNITED STATES OF AMERICA FLAGGED VESSELS May 2005 108

.1: Scope This document consists of of the Alternate Compliance Program U.S. supplement to Lloyd s Register s Rules and Regulations for the Classification of Ships, Rev. 1.0, approved on 23 November 2003 and in addition to the other requirements of this supplement is only applicable to Passenger Catamaran Vessels operating in displacement mode, certificated or to be certificated under 46 CFR Subchapter H subject to all International Conventions (SOLAS, MARPOL, Load Line) of steel or equivalent construction and classed in accordance with Lloyd s Register s Rules and Regulations for the Classification of Special Service Craft, July 2003, with the following minimum classification notation: 100A1 SSC Passenger Catamaran or 100A1 SSC Passenger Catamaran May 2005 109

.2: Use of Lloyd s Register Rules and Regulations for the Classification of Special Service Craft. The Lloyd s Register Rules and Regulations for the Classification of Special Service Craft (SSC Rules) covers the structural design, watertight integrity and standard of construction of the hull and construction, installation and testing of the propulsion machinery, essential auxiliary machinery, essential piping and electrical systems to the extent indicated for various ship and hull types not covered by the Lloyd s Register Rules and Regulations for the Classification of Ships (Ship Rules). However, the requirements contained in this Supplement are intended to be applied together with the Ship Rules and the international conventions. Accordingly, this section describes those portions of the SSC Rules that are substituted for portions of the Ship Rules for application to passenger catamarans classed under the SSC Rules and assigned service notation. Where any aspect of the design or construction is not covered by the SSC Rules, the relevant requirements of the (Lloyd s Register) Rules and Regulations for the Classification of Ships will be applied as considered necessary, in accordance with SSC Rules, Part 1, Ch. 2, 2.1.6. In general, the structural requirements contained in the Lloyd s Register SSC Rules are based on direct (first principle) calculations rather than the empirical approach taken in the Lloyd s Register Ship Rules. The Engineering Systems (Machinery and Piping); Electrical and Control Engineering parts of the Lloyd s Register SSC Rules are based from a technical standpoint on the Lloyd s Register Ship Rules modified to account for multi-hulled vessels and high speed light displacement craft. The arrangements and equipment of a passenger vessel classed by the SSC Rules are required to comply with the applicable requirements of the following international conventions: International Convention on Load Lines, 1966, as modified by the 1988 Protocol relating thereto; International Convention for the Safety of Life at Sea, 1974, as amended; International Convention for the Prevention of Pollution from ships, 1973, as modified by the Protocol of 1978 relating thereto, The following listing delineates the parts of the Lloyd s Register SSC Rules which are substituted for the Lloyd s Register Ship Rules subject to system specific requirements referenced in Section 11.3 of this Addendum: Part 1, Chapter 1 to 3 for LR Ship Rules Part 1, Chapters 1 to 3 Part 3, Chapter 1, Part 5, Chapter 1, Part 6, Chapter 1 for LR Ship Rules, Part 3, Chapter 1 Part 3, Chapter 2 for LR Ship Rules, Part 3, Chapter 3 Part 3, Chapter 3 and Chapter 5 for LR Ship Rules, Part 3, Chapter 13. Part 3, Chapter 4, for LR Ship Rules, Part 3, Chapter 11 Part 5, Chapters 2, 4 and 5 and; Part 6, Chapters 3, 4 & 7 for LR Ship Rules, Part 3, Chapter 5 to 7. Part 6, Chapter 2, for LR Ship Rules, Part 3, Chapter 10. Part 6, Chapter 3, for LR Ship Rules, Part 3, Chapter 8 Part 6, Chapter 5, for LR Ship Rules, Part 3, Chapter 9 Part 6, Chapter 5 for LR Ship Rules, Part 4, Chapter 2 The following listing delineates the parts of the Lloyd s Register SSC Rules which are to be complied with in addition to the Lloyd s Register Ship Rules for Ship and Machinery Piping Systems: Part 15, Chapter 2, Section 12 Multi-Hull Craft Requirements Part 15, Chapter 3, Section 8 Multi-Hull Craft Requirements May 2005 110

.3: Additional Requirements for SOLAS Passenger Catamaran vessels classed under Lloyd s Register SSC Rules. The vessel s Service Restriction and significant wave height for design purposes are to be mutually agreed with the USCG Marine Safety Center and the OCMI. 46 CFR 71.50-3 Drydock examination, internal structural examination, underwater survey, and alternate hull exam intervals. Vessels must undergo a drydock and internal structural examination once every 12 months unless approved to undergo an underwater survey in lieu of drydocking as per 46CFR71.50-5. 46 CFR 72.10: Means of Escape Reference is made to Section 4.1 & 9.1 of the Supplement and additionally as follows: 46 CFR 72.10-45: Weather deck communications. (a) Vertical communication shall be provided between the various weather decks by means of permanent inclined ladders. Where ladders are for the exclusive use of the crew for rapid communication and do not form part of a normal escape route, vertical ladders may be employed. 46 CFR 72.15: Ventilation 46 CFR 72.15-10: Vessels using fuel having a low flash point of 110 deg F or lower For craft having oil fuel with a flash point below 110 F the arrangements for the storage, distribution and utilisation of the oil fuel are to be such that the safety of the craft and persons on board is preserved, having regard to fire and explosion hazards. The arrangements are to comply with the following requirements:- Tanks for the storage of such oil fuel are to be located outside any machinery space and at a distance of not less than 30 inches inboard from the shell and bottom plating, and from decks and bulkheads. (Reference is made to SSC Rules Part 15, Chapter 3, 5.1.2) The spaces in which oil fuel tanks are located are to be mechanically ventilated using exhaust fans providing as per the table below Size of Space ft 3 Minutes per air Change Over Not Over -- 500 2 500 1000 3 1000 1500 4 1500 -- 5 Exhaust blower motors shall be outside of the ducts, and if mounted in any compartment required to be ventilated by this section, shall be of the explosion proof type. Blower blades shall be nonsparking with reference to their housings. The outlets for such exhausts are to discharge to a safe position. Exhaust blower switches shall be located outside of any space required to be ventilated by ths section and shall be of the type interlocked with the ignition switch so that the blowers are started before the engine ignition is switched on. A red warning sign at the switch shall state that the blowers shall be operated prior to starting the engines for a sufficient time to insure at least one complete change of air in the compartments served. May 2005 111

The area of the ducts shall be such as to limit the air velocity to a maximum of 2,000 feet per minute. Ducts may be of any shape, provided that in no case shall one dimension exceed twice the other. At least two inlet ducts shall be located at one end of the compartment and they shall extend to the lowest part of the compartment or bilge on each side. Similar exhaust ducts shall be led to the mechanical exhaust system from the lowest part of the compartment or bilge on each side of the compartment at the end opposite from that at which the inlet ducts are fitted. All ducts shall be constructed of non-ferrous metal or galvanized ferrous metal not less than No. 22 USSG, intact and gastight from end to end and shall be of substantial construction. The ducts shall lead as direct as possible and be properly fastened and supported. All supply ducts shall be provided with cowls or scoops having a free area not less than twice the required duct area. When the cowls or scoops are screened, the mouth area shall be increased to compensate for the area of the screen wire. Dampers of the supply ducts are to be interlocked to the exhaust fans to remain always open except in the event of a fire. Cowls or scoops shall be kept open at all times except when the stress of weather is such as to endanger the vessel if the openings are not temporarily closed. Supply and exhaust openings shall not be located where the natural flow of air is unduly obstructed, or adjacent to possible sources of vapour ignition, nor shall they be so located that exhaust air may be taken into the supply vents. A fixed vapour detection system is to be installed in each space through which oil fuel lines pass, with alarms provided at a continuously manned control station. (Reference is made to SSC Rules Part 15, Chapter 3, 5.1.4) Safe and efficient means of ascertaining the amount of oil fuel contained in any tank is to be provided. Gauge glasses are not to be used. Other means of ascertaining the amount of oil fuel contained in any tank may be permitted if such means do not require penetration below the top of the tank, and providing their failure or overfilling of the tanks will not permit the release of oil fuel. (Reference is made to SSC Rules Part 15, Chapter 3, 5.1.5) Vessel to shore oil fuel connections are to be of closed type and suitably grounded during bunkering operations. (Reference is made to SSC Rules Part 15, Chapter 3, 5.1.6) Air pipes shall discharge to a safe position and terminate with flame arresters in accordance with MSC. Circ./677. (Reference is made to SSC Rules Part 15, Chapter 3, 5.1.7) 76 CFR 72.15-20 Ventilation for crew quarters and passengers spaces. (a) All crew and passenger spaces shall be adequately ventilated in a manner suitable to the purpose of the space. (b) Reference is made to Section 4.1 of the Supplement (46 CFR 92.15-15(b)). 46 CFR 72.25 - Passenger Accommodations 46 CFR 72.25-10: Location of Passenger Quarters (a) Deck forming the deckhead of passenger quarters/accommodation between adjacent watertight bulkheads shall not be below the deepest load line at any point within the watertight compartment in question. 46 CFR 72.25-15 Passenger Accommodations for excursions boats, ferryboats and passenger barges. (a) Separate public toilet spaces shall be provided for male and female passengers with at least the minimum equipment in each based upon the number of passengers permitted to be carried as set forth below: May 2005 112

Number of Passengers Over Not Over Toilets Washbasins 0 100 1 1 100 300 2 1 300 500 3 2 500 1000 4 2 1000 1500 5 3 1500 2000 6 3 2000 2500 7 4 2500 3000 8 4 3000 3500 9 5 3500 4000 10 5 4000.. Additional by extrapolation Additional by extrapolation (b)in men s spaces, urinals may be substituted for toilets, provided at least one-half the required toilets are fitted. (c) On ferryboats and barges having a short run, passenger toilet facilities need not be fitted. 46 CFR 72.40-10 Storm Rails (a) Suitable storm rails shall be installed in all passageways and at the deckhouse sides where passengers or crew might have normal access. Storm rails shall be installed on both sides of passageways which are 6 feet (1829 mm) or more in width. 46 CFR 72.40-25 Vehicular Ferries (a) On vehicular ferries, suitable chains, cables or other barriers shall be installed at the ends of the vehicle runways. In addition suitable gates, rails or other devices shall be installed as a continuation of the regularly required rails. 46 CFR 72.40-20 Guards in dangerous places (a) Suitable covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery, etc.. 46 CFR 76: Fire Protection Equipment. Reference is made to Sections 5.1, 5.2 & 9.1 of the supplement specifically and additionally as follows: Fire Rated windows are not currently covered under the Mutual Recognition Act (MRA). Therefore, A and B-class fire rated windows must be subject to the testing set forth in the IMO Fire Test Procedures Code, Annex, Chapter 3, and must comply with the following table for hose stream and thermal radiation tests: Window Area Fire Rating Hose Stream Test Required? Heat Flux Test Required? 645cm 2 A-Class No No 645cm 2 A-Class Yes Yes 645cm 2 A-0 Yes No 645cm 2 B-15 No No 645cm 2 B-15 No Yes Any Dimension B-0 No No 46 CFR 76-05-20 (Table 76.05-1(a)) A CO 2 fixed fire extinguishing system being installed for protection of the enclosed ventilating systems for motors and generators of electric propelling machinery. May 2005 113

46 CFR 76.17 Foam Extinguishing Systems, Details Where a fixed low expansion foam extinguishing system is installed for the protection of Machinery Space bilges it shall comply with FSS Code, Annex, Ch. 6, Section 2.3 and the following additional requirements: 46 CFR 76.17-5 Quantity of Foam Required. (a)(2) Where an installation is made to protect a oil fired boiler installation on a flat which is open to or can drain to the lower engine room or other space, both the flat and the lower space shall be protected simultaneously. The flat shall be fitted with suitable coamings on all openings other than deck drains to properly restrain the oil and foam at that level. (c)(2) A separate supply of foam agent need not be provided for each space protected. The total available supply shall be at least sufficient for the space requiring the greatest amount. (c)(3) Where pumps are required, the water supply shall be from outside the space protected and shall in no way be dependent upon power from the space protected. 46 CFR 76.17-10 Controls The foam agent, its container, and all controls and valves for the operation of the system shall be of an approved type. Where system pumps are required, it shall not be necessary that they be started from the control space. Complete, but simple instructions for the operation of the system shall be located in a conspicuous place at or near the controls. Foam apparatus, the control cabinets or spaces containing valves or manifolds for the various fire extinguishing systems shall be distinctly marked in conspicuous red letters at least 50 mm (2 in) high "FOAM FIRE APPARATUS". 46 CFR 76.17-15 Piping Piping, valves and fittings shall meet the applicable requirements of LR Rules, Part 5, Ch. 12 as modified by the requirements of the supplement. All piping valves and fittings of ferrous materials shall be protected inside and outside against corrosion unless specifically approved otherwise. Materials readily rendered ineffective by heat of a fire shall not be used. All piping, valves, and fittings shall be securely supported, and where necessary, protected against injury. Drains, strainers and dirt traps shall be fitted where necessary to prevent the accumulation of dirt or moisture. Threaded joints shall be metal to metal, with no thread compound used. Distribution piping shall be used for no other purpose. All piping shall be thoroughly cleaned and flushed before installation of the discharge outlet. 46 CFR 76.17-20 Discharge Outlets Discharge outlets shall be USCG approved. 46 CFR 76.60 Fire Axes Requirements of this part are satisfied by the provision of Fire Fighters outfits and personal protective equipment in accordance with SOLAS II-2/10.10 and FSS Code Ch. 3, Section 2.1. 46 CFR 56.50-50 Bilge and Ballast System: Each hull of vessel with more than one hull must have at least two means for pumping the bilges in each hull. For multi-hull craft the value of molded Breadth, B used in evaluation of the bilge main sizing and capacity is as defined in Part 3, Ch. 1, 6.2.7., LR SSC Rules as the greatest moulded breadth, in metres for multi-hull craft it is to be taken as the sum of the breadths of the individual hulls. May 2005 114

Where the bilge system in each hull is entirely separate, then each hull bilge system should comply with the requirements of Part 5, chapter 13, section 3 to 8 of the Rules and Regulations for Classification of Ships and the current Lloyds Register-USCG Supplement. 46 CFR 52 Power Boilers Power boilers are to be designed, constructed, inspected and tested in accordance with ASME Section I with additional requirements and modifications as specified in 46 CFR 52. Automation, installation and inspection shall comply with the requirements of Part 5, Chapter 10 of the Ship Rules or the ASME Code 46 CFR 53 Heating Boilers Heating boilers are to be designed, constructed, inspected and tested in accordance with ASME Section IV with additional requirements and modifications as adopted in 46 CFR 53. Automation and installation and inspection shall comply with the requirements of Part 5, Chapter 10 of the Ship Rules or the ASME Code Section IV. 46 CFR 78.47-35 Fire Doors. All doors in main vertical zone bulkheads or stairway enclosures, except from individual rooms such as staterooms, fan rooms, lockers, etc., shall be numbered conspicuously on an etched plate or equivalent in not less than 10mm (3/8 inch) letters and figures ``F. S. D. 1,'' ``2,'' ``3,'' etc. If stenciled or similar notice is used, the letters and figures shall be at least 25mm (1 inch) high. The number shall be conspicuous with the door in the open position May 2005 115