MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Similar documents
Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Digital/Analog Megohmmeter Model 1026

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

4-WIRE EARTH RESISTANCE TESTER C1 ES P1 S. Max. AC 200V MICROPROCESSOR CONTROLLED TEST. Switch ON, TEST, SCROLL RESULTS 20Ω 200Ω 2000Ω OFF

OPERATING INSTRUCTION

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

1.Safe testing IMPORTANT:

Safety design conforming to the following provisions

OPERATING INSTRUCTION

Digital/Analog Megohmmeter Model 1026 USER MANUAL

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

User Guide. Model Insulation Tester / Megohmmeter

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Safety design conforming to the following provisions

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

3 PHASE TESTER & MOTOR ROTATION TESTER

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

DIGITAL RCD(ELCB) TESTER

KMP Insulation-Continuity Tester. Users Manual

Model Insulation Tester / Megohmmeter. User Manual

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

User Guide. Model Insulation Tester / Megohmmeter

Mini Multimeter with Non-Contact Voltage Detector (NCV)

User's Manual Digital High Voltage Insulation Tester Model

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

OPERATING INSTRUCTION

User's Manual. Earth Ground Resistance Tester. Model Introduction

Mini Multimeter with Non-Contact Voltage Detector (NCV)

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

WENS30C Loop Calibrator

Autoranging Multimeter

Distributor. Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA KEWTECH

USER MANUAL. Insulation Tester + DMM. Model MG320

BM kv Digital Insulation Tester USER MANUAL

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

True RMS Autoranging Multimeter

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

Autoranging Industrial Multimeter

User Guide. Model Insulation Tester / Megohmmeter. Introduction

KEWTECH. KT56 digital multi function tester. Instruction manual

Non-Contact Phase Rotation Tester

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Declaration of Conformity

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

Non-Contact Phase Rotation Tester

Instruction Manual. Model 310 Digital Milli-Ohm Meter

BATTERY OPERATED DIGITAL MILLI-OHMMETER

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

Table of Contents Title Page No.

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Volt/mA Calibrator. Manual

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

MIT300 Series Insulation and Continuity Testers

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

HIGH VOLTAGE PROVING UNIT

DIGITAL INSULATION TESTER RS-5500/5505 INSTRUCTION MANUAL

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

SafetyPAT Plus A B P/N:

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Solar Power Light Meter

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice.

OPERATING INSTRUCTIONS

Users Manual. MegOhmMeter

707Ex. Users Manual. ma Calibrator

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

Digital Multimeter User's Manual

HD110C Heavy-Duty Digital Multimeter

KD1E Range Potential Indicators

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

Model UT601: OPERATING MANUAL

KTD30 Digital Insulation and Continuity Tester. User Manual. kewtechcorp.com

Transcription:

INSULATION TESTER EARTH MAX. AC 600V LINE AC -+ HOLD V k M LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT M H.V. POWER DATA HOLD TEST ON / OFF 250V 500V 1000V ACV OFF 0 CAT.III 600V INSTRUCTION MANUAL

INDEX Instrument Layout... Introduction... Safety Notes... Features... Measuring Methods... Specifications... Maintenance... Page 1 2 3 4 5-7 8 10

Instrument Layout OUTPUT TERMINAL EARTH MAX. AC 600V LINE AC HOLD V k M LCD DISPLAY -+ EXTERNAL VOLTAGE INDICATOR LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT M H.V. POWER POWER INDICATOR DATA HOLD BUTTON DATA HOLD TEST ON / OFF 250V 500V 1000V ACV OFF 0 TEST BUTTON NULL ADJUST CAT.III 600V FUNCTION SWITCH 1

1. Introduction NOTE This meter has been designed and tested according to IEC publication 348, safety requirements for electronic measuring apparatus, IEC-1010 (EN 61010) and other safety standards. Follow all warnings to ensure safe operation. WARNING READ SAFETY NOTES ( NEXT PAGE ) BEFORE USING THE METER. 2

2. Safety Notes Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified in this manual ; otherwise the protection provided by the meter may be impaired. Rated environmental conditions : (1). Indoor use. (2). Installation Category III. (3). Pollution Degree 2. (4). Altitude up to 2000 Meter. (5). Relative Humidity 80% Max. O O (6). Ambient Temperature 0 ~40 C. Observe the international electrical symbols listed below: Meter is protected throughout by double insulation or reinforced insulation. Warning! Risk of electric shock. Caution! Refer to this manual before using the meter. Alternating current. 3

3. Features 3½ Digit Insulation Tester. 68mm x 34mm ( 1.338 x 2.677 ) large LCD display. Three insulation test voltage : 250V, 500V, 1000VDC. External voltage warning indication. Automatic circuit discharge. Test insulation at rated voltage into a 1 ma load. 200 ma continuity short circuit test current. AC voltage measurement. Fuse protection. th Meet IEC 1010 CAT., BS 16 edition. Timer for test function (count 3~5 minutes) Data hold function. Auto power off function. 4

4. Measuring Methods OPERATION CAUTION Observe all safety precautions when the FUNCTION switch is set to 250,500V,1000V position. Connect the meter test leads to the circuit under test before operating the TEST button. Do not touch the clip ends of the test leads when the TEST button is pressed. Some electrical equipment, especially cables, may retain an electrical charge when disconnected from the line. It is good practice to discharge such equipment with grounding straps, or other suitable devices, before touching or making connections. The meter automatically discharge the test circuits when the spring loaded TEST button is released. IMPORTANT Remove all power to the circuit under test when making resistance measurements. If any voltage is present in the test circuit the LED on the meter scale plate will light. Immediately disconnect the test leads and turn off power to test circuit. FUNCTION SWITCH : The FUNCTION switch is used to select the range, or function desired. TEST BUTTON : The TEST button is normally OFF, press to test. Always check the following before testing : The Battery Low indicator is not showing. There is no visual damage to the instrument or test leads. 5

Test Lead Continuity Select the CONTINUITY function and range. Short the test leads together. An over-range ( 1 ) indication mean the leads are faulty or instrument fuse is blown. (See Fuse Replacement section). Insulation Resistance Testing: Warning: Insulation tests should be conducted on circuits that are de-energised. Ensure circuits are not live before commencing testing. Select the required test voltage (250V, 500V or 1000V) by rotating the FUNCTION switch. Connect the test leads to the instrument and to the circuit to be tested. (See connect diagram). If the LIVE CIRCUIT is light, do not press the TEST button and disconnect the instrument from the circuit. The circuit is LIVE and should be de-energised before further testing. Press the TEST button. The value of insulation resistance in megohms will be displayed. INSULATION GUARD EARTH MAX. AC 600V LINE CABLE CORE LINE OUTER SHEATHING EARTH Connect Diagram COVERING 6

Caution: Never turn the function dial while the button is depressed. This may damage the instrument. Never touch the circuit during insulation testing. When testing is complete ensure the TEST button is released before the test leads are disconnected. This is because the system may be charged up and it must be allowed to discharge through the tester's internal discharge resistor. Continuity discharge (Resistance tests) Warning: Ensure circuit is not live before commencing testing. Select the 20 range by rotating the FUNCTION switch and connect the test leads to the instrument. Short the tips of the test leads. Press and hold down the TEST button by twisting it clockwise. The display will show the resistance of the test leads. Adjust the Null control to set the reading to zero. Connect the test leads to the circuit under test. Ensure the circuit is not live by checking that the live circuit indicator does not light. Read the value of resistance from the LCD. AC voltage test : Set the FUNCTION switch to ACV. Connect test leads to circuit being measured. Press TEST button and read the value of voltage from the LCD. 7

5. Specifications Insulation Resistance Auto range : 20M / 200M / 2000M 20M Resolution : 1 count / 10k Accuracy : ± 1.5% rdg. ± 5 dgt. 200M Resolution : 1 count / 100k Accuracy : ± 2.5% rdg. ± 3 dgt. 2000M Resolution : 1 count / 1M Accuracy : ± 5% rdg. ± 5 dgt. Output current : 1mA DC min. at 0.25M (250V range) 1mA DC min. at 0.5M (500V range) 1mA DC min. at 1M (1000V range) Power consumption : Max. consumption current Approximately 250mA AC Voltage Range : 0-600V Resolution : 1V Accuracy : ± 1.5% rdg. ±3 dgt. Line frequency range : 40-120 Hz. Continuity Auto range : 20 /200 /2000 Min Resolution : 0.01 Accuracy : ± 1.5% rdg. ± 3 dgt. Open circuit terminal voltage : 4V DC min. Short circuit terminal current : 210mA DC min. Power consumption : Max. consumption current approximately 160mA Buzzer sounds under 10-8- 8

Withstand : Meet IEC-1010 safety requirements Category III Dimension : 205(L) x 90(W) x 55(D) mm Weight : Approx. 600g ( batteries included ) Standard Accessories : Batteries 1.5V, size AA Test Leads Fuse 0.5A 250V Instruction Manual 6 pieces 1 pair 1 piece 1 vol. Auto power off : Timer about 5~10 minutes (Current consumption:10µa) 9

6. Maintenance Caution : Always disconnect the test leads from instrument before batteries or fuse Batteries Replacement : Please replace batteries when the Battery Low indicator was shown on the LCD. Disconnect the test leads from the instrument, remove the battery compartment lid and the batteries. Replace with six 1.5V AA batteries, taking care to observe correct polarity. Alkaline batteries are recommended. Replace the battery compartment lid. Fuse Replacement : Open the battery compartment lid. Remove the fuse cove and the old fuse, and replace with the new one. Replace the fuse cover and screw the battery compartment lid before using the tester. Cleaning and Storage: Periodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents. If the meter is not to be used for periods of longer than 60 days, remove the batteries and store them separately. WARNING To avoid electrical shock or damage to the meter, do not get water inside the case. 10

CAT IV - Is for measurements performed at the source of the low-voltage installation. CAT III - Is for measurements performed in the building installation. CAT II - Is for measurements performed on circuits directly connected to the low-voltage installation. CAT I - Is for measurements performed on circuits not directly connected to Mains. Due to our policy of constant improvement and development, we reserve the right to change specifications without notice. 11