Setting the Standard in Mobile Power HYDRO 500-CD-16. Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

Similar documents
HYDRO 600E 10cc. Hydraulic Generator INSTRUCTION MANUAL FOR MODEL. Setting the Standard in Mobile Power

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

HYDRO Instruction Manual for Model. Hydraulic Generator. Setting the Standard in Mobile Power

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

HYDRO 300C-6 Hydraulic Generator

HYDRO - 200CX HZ

HYDRO 12KCD 16-3 Hydraulic Generator

HYDRO 800KEP 11-3 Hydraulic Generator

Instruction Manual for Model HYDRO 12-KP 11-3 PHASE GENERATOR. Hydraulic Generator. Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

SGB12000HX PORTABLE GENERATOR

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...


ALTERNATOR - CHRYSLER 40/90-AMP & 50/120 AMP

Commercial generator set Hydraulic Series HG 25000

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

Starting up hydraulic systems

PM300E Voltage Regulator Instruction Manual

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

Model 5-025, 5-050, &

Machine Component Identification Items: , ,

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS:

ALTERNATOR - BOSCH 35/75-AMP & 40/90-AMP

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

Unit 32 Three-Phase Alternators

Operation & Service Manual

CONTENTS. Product Features and Specifications...1. Installation Requirement...3. Steps of Installation...4. Exploded View Test Run...

AHFP-im-issue INSTRUCTION MANUAL HIGH FLOW DIESEL PUMP AHFP70LPM (70LPM) AHFP100LPM (100LPM) AHFP150LPM (150LPM) AHFP70LPM AHFP100LPM AHFP150LPM

D-Series Blowers and Exhausters

WELDING FUME EXHAUSTERS & ARMS

Installation & Operating Manual

User s Manual D-Series Blowers and Exhausters

Hydrostatic Drive. 1. Main Pump. Hydrostatic Drive

This chapter contains information on DC Generation, External Power, and Electrical Load Distribution.

CONTENTS. Product Features and Specifications Installation Requirement Steps of Installation 4. Exploded View Test Run...

Portable Oil Free Silent Series Compressor Operating Instructions

CONTENTS. Product Features and Specifications Installation Requirement Installation Exploded View Operation Instruction...

3000W POWER INVERTER. User Manual

Power Steering Units - Eaton / Char-Lynn

Section 7.1. Wheel Drive Circuit - General System

FAULT FINDING MANUAL. For Stamford AC Generators

FIRE-POWER 12 & 14 KW SELF-CONTAINED HYDRAULICALLY DRIVEN ELECTRIC POWER GENERATOR SYSTEM

6L Oil-less Air Compressor 53103

WORKSHOP MANUAL. 63,4 cm³ chainsaws

AG. 225 AGRICULTURAL SYSTEMS/ELECTRICITY AND HYDRAULICS

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

DC disconnect. #4 AWG Negative wire

9/3/2008. Item No. Qty. MSRP Dealer Cost. Part No. UPC Number Description Baja Description

PANCAKE AND HOT DOG AIR COMPRESSORS PARTS LIST

Battery Powered Hydraulic Pump; Kit PN [ ]

Tests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator

Designed for Light to Medium Industrial Repair

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual

DIAGNOSIS AND TESTING

3 Phase Smart Controller

PRO6.4, PRO6.4E, PRO9.0, PRO9.0E Generator Service Manual

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

ALTERNATOR REQUESTED INFORMATION. Vehicles With Dual Generator [ Engine Mount - LH ] 2007 Ford Pickup 6.0L Eng F350 Super Duty

NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures

ATD-5925 RECHARGEABLE 12 VOLT 18 AMP/HOUR JUMP START WITH BUILT-IN 260 PSI AIR COMPRESSOR OWNERS MANUAL

Spare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

POWER MODULE MTU 16V4000 DS2560

VAC Electrical Requirements. VDC Electrical Requirements

4.0L CEC SYSTEM Jeep Cherokee DESCRIPTION OPERATION FUEL CONTROL DATA SENSORS & SWITCHES

INDEX Section Page Number Remarks

Model No. 668D3. COFFEPUMP Part No Product Code: O/C GJAN21.DB6B-DC310B

RENTAL DIESEL GENERATOR SET

OWNER S MANUAL POWER INVERTER

ADVANCED PID TROUBLESHOOTING

PT, PTS & PTP Series Pump/Reservoirs

INDUSTRIAL GENERATOR SERVICE

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Spreader Valves SPR-2FFL12, SPR-2FFLC12 & SPR-2FFLW86

SERVICE MANUAL DGK25E DGK25EU

Multiquip Submersible Pump Model ST-3050D

Section 6.1. Implement Circuit - General System. General: Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

WALKIE HIGH LIFT HYDRAULIC SYSTEM

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Charging Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 19 Pages Charging Systems 42 Points. Please Read The Summary

LINEAR ACTUATOR MODULE Page 5-1. Table Of Contents

Item No. Specifications Selection Performance Pump Sectional View Chart Curve Dimensions

Intake Air Temperature 2 (IAT2 ) Sensor

1/12, 1/6, 1/4, 1/3, 1/2, 3/4 & 1.0 HP

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

REPAIR MANUAL AFX8010

ALTERNATOR PRECAUTIONS. Some precautions should be taken when working on this, or any other, AC charging system.

ELECTRICAL SYSTEM RP-7

CONTENTS. Product Features and Specifications...1. Installation Requirement Steps of Installation.. 5. Exploded View Test Run...

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

PRECISION UK Ltd DUPLEX AGSS PLANT

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

INSTALLATION INSTRUCTIONS

Transcription:

Setting the Standard in Mobile Power HYDRO 500-CD-16 Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

GENERAL INFORMATION MODEL: HYDRO 500-CD-16 Page 2

RECOMMENDATIONS MODEL: HYDRO 500-CD-16 A OIL COOLER IS RECOMMENDED WITHOUT A COOLER INSTALLATION TIPS Excessive pressure in your return line will damage the hydraulic motor seal. High back pressure can be caused by spikes sent back through the return from other equipment on a common return line. Another potential problem can develop if several pieces of equipment are connected to one common return line causing a high back pressure (150 PSI is the maximum). We recommend you run the case drain line from the generator back to the cooling tank with a separate line. If our hydraulic generator is to be used on a truck or system that will be changing speeds, such as, in a fire truck (pumping water) we suggest you use a load sensing piston type pump rather than a fixed displacement gear type. The system will run much cooler and more efficient. Page 3

Initial Installation and Start-Up Be sure you set the hydraulic flow (GPM) to the generator at Approximately 62.5 HZ or 3750 RPM with NO electrical load on the generator. By using this setting you will have approximately 60HZ (cycles) or 3600 RPM when you are running at full rated load. One way this can be accomplished is by using a Photo Tachometer on our generator coupling or generator cooling fan. A Photo Tachometer is an inexpensive tool that can be purchased at McMasters, Grainger, Sears or any other electrical supplier. Page 4

TECHNICAL INFORMATION These self-excited and self-regulating generators, although overall dimensions have been reduced to a minimum, are designed for high-level electrical performance and the maximum in operating reliability. PRELIMINARY CHECKS: STARTING UP: THE IMPORTANCE OF SPEED: CHECKING VOLTAGE: CHECKING THE DIODES: Before touching the machines, perform a thorough and in depth visual inspection, checking that components are correctly connected up and that no cables or terminals are broken or loose. Make sure, when starting up, that cooling air intake and discharge openings are free and unblocked. We also recommend (when the machine operates in a dusty environment) do periodic checks to make sure it is properly ventilated Frequency and voltage depend directly on rotation speed. This must be kept as constantly as possible on its nominal value no matter what the load. Drive motor speed control systems generally have a small drop in speed between no load and loaded conditions. We therefore recommend setting no load speed 3 4% above nominal speed. All the machines are regulated during factory testing. If voltage readings differ from the value indicated on the name plate, this maybe caused by a mistaken reading or by a different rotation speed and we recommend regulating motor speed in order to have nominal RPM under loaded conditions. For the ohmmeter test it is best to disconnect the diode from its circuit. Measure continuity in one direction only. The test can also be made without disconnecting the diode form the circuit, using a 12V battery and a 45 watt light bulb (automobile light) as shown in the illustration. The light should turn totally on only in one direction, as shown below. WINDING RESISTANCE AT 20 C ROOM TEMPERATURE Size Stator Rotor Exciter 3.5 0.7 9.22 4.0 4.0 0.7 9.28 4.0 5.0 0.54 2.97 2.24 6.0 0.54 2.97 2.24 8.0 0.49 2.85 4.41 12.0 0.250 5.65 0.60 Page 5

ELECTRICAL CONNECTIONS CONNECT NEUTRAL TO GROUND IF USING GFCI OUTLETS NEUTRAL (WHITE) U2 V2 120/240 VOLT OPERATION 120 120 V1 W1 RED OR BLACK WIRE 240 25 AMP OVERLOAD SELF RE-SETTING GROUND SCREW ON GENERATOR FRAME. USE GREEN WIRE FOR GROUND IF USING GFCI OUTLETS TERMINAL BLOCK RED OR BLACK WIRE JUMPER (BLACK) 30 AMP OVERLOAD SELF RE-SETTING U2 V2 NEUTRAL (WHITE) HOT LEAD (BLACK) V1 120 W1 120 VOLT FULL POWER OPERATION GROUND SCREW ON GENERATOR FRAME. USE GREEN WIRE FOR GROUND IF USING GFCI OUTLETS TERMINAL BLOCK Page 6

PARTS BREAKDOWN HYDRO 500-CD-16 No. PART # DESCRIPTION 1 572262 Louvered Panel 2 572268 Frame For Stator 3 572182 Drive End Bell 3 a 572265 Screen 4 572235 Front Bearing 5 572184 Fan 6 572269 Rotor 8 572064 Rear Bearing 13 572186 User Terminal Board 15 572260 Cover 17 572288 Capacitor (31.5mfd) 19 572196 Diodes 20 572065 Channel 21 572066 Coupling 24mm 22 572067 Spider 23 572192 Coupling 5/8 24 572362 Motor 16cc w/case drain 25 572128 Rails 26 572154 Mounts 28 572261 Stud Cover 29 572263 Rubber Cup 30 572272 Fan Ring PART # OPTIONAL CONTROL PANEL 572233 Flow Control Assy. 15 GPM (opt.) 572227 Complete Control Panel 572240 Flow Control Cartridge only (opt.) 572228 Control Box (Shell) 572254 Seal For Hydraulic Motor 572052 Volt Meter 572274 Generator Complete 572054 Receptacle 120 Volt 572159 Voltage Indicating Light 572100 Waterproof Recpt. Cover 572157 Overload Protection Device 572226 GFI Outlet 120 Volt Page 7

TROUBLE SHOOTING PROBLEMS CAUSES REMEDIES ALTERNATOR EXCITATION FAILURE 1. Low Speed 2. Faulty capacitor 3. Faulty winding 1. Check RPM and set at nominal value. 2. Check and replace. 3. Check that winding resistance is as shown in the tables. HIGH NO-LOAD VOLTAGE LOW NO-LOAD VOLTAGE PROPER NO-LOAD BUT LOW LOADED VOLTAGE UNSTABLE VOLTAGE NOISY GENERATOR 1. Speed too high. 2. Capacitor with high capacity. 1. Speed too low. 2. Faulty rotary diodes. 3. Breakdown in windings. 4. Capacitor with high capacity. 1. Low loaded speed. 2. Load too large. 3. Rotary diodes short-circuited 1. Loose contacts. 2. Uneven rotation. 1. Broken bearings. 2. Poor couplings. 1. Check and adjust RPM s 2. Check and replace 1. Check and adjust RPM s 2. Check and replace. 3. Check winding resistance, as per tables. 4. Check and replace. 1. Check and regulate RPM. 2. Check and change. 3. Check and replace. 1. Check connections. 2. Check for uniform rotation speed. 1. Replace. 2. Check and repair. Page 8

FIXED DISPLACEMENT TYPE GEAR PUMP 5 6 4 3 7 2 1 TYPICAL HYDRAULIC SCHEMATIC 8 1. HYDRAULIC PUMP 2. PRESSURE RELIEF VALVE 3. CONTROL VALVE 4. PRIORITY FLOW CONTROL* 5. GENERATOR HYRAULIC MOTOR 6. CASE DRAIN LINE** 9 7. RETURN LINE FILTER 8. OIL COOLER 9. HYDRAULIC FLUID RESERVOIR * Some units may be equipped with integral priority flow control, refer to specific model number. ** External case drain line may be required on some units refer to specific model number. When external case drain is required it should be unobstructed direct return to reservoir with a minimum I.D. no less than that of case drain port on generator motor. FOR SPECIFIC INSTALLATION RECOMMENDATIONS CONSULT FACTORY Page 9

BRUSHLESS GENERATOR WIRING Page 10

FABCO BY-PASS FLOW CONTROL FABCO PN 572233 NOTE: THIS ASSEMBLY ONLY NEEDED WITH FIXED DISPLACEMENT TYPE GEAR PUMP. Page 11

Page 12

Page 13