Zone Selective Interlock Module. For GE Circuit Breakers

Similar documents
Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

Zone Selective Interlocking

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

GEH-6259 Installation Instructions Voltage Conditioner Assembly

Selective Coordination

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

Evaluating Selective Coordination Between Current-Limiting Fuses And Non Current-Limiting Circuit Breakers

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

Evaluating Selective Coordination Between

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

EE 741 Over-voltage and Overcurrent. Spring 2014

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

3.2. Current Limiting Fuses. Contents

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Selective Coordination Enforcement:

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Position Switch Kits Accessory Kits for EntelliGuard* Retrofill Circuit Breakers

SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

PowerOhm Installation Manual for BM R Series Braking Modules

Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units

F-Series. Circuit Breaker

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

A. Submit manufacturer's literature and technical data before starting work.

F-Series. Circuit Breaker

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

Solar PV Standard Electrical Plan

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

E.S.P. Embedded Sensing Probes for Motor Brushes

Operation and Maintenance Manual

9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC

Arc-Flash Mitigation Technologies. Dennis Balickie

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

ECET Distribution System Protection. Overcurrent Protection

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Installing Power Components

PD-Series Ground Fault Circuit Protection

Functional Overview and Operating Principles for the AR-OH and AR360 Overhead AutoRANGER Fault Indicators

PowerOhm Installation Manual for BM R Series Braking Modules

2016 Photovoltaic Solar System Plan Review List

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Selective Coordination Requirements

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Advanced Protective Relay Training

PowerOhm Installation Manual for LG ATV Series Braking Modules

BATTERY SAVER LOW RIPPLE HO

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Application Engineering

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Advanced Monolithic Systems

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018

Service Entrance Methods

5. OVERCURRENT RELEASE (OCR)

CM52 Network Protector with Arc Flash Reduction Module

Design Standards NEMA

Publication No.: PSG

Application of Sepam Relays for Arc Flash Hazard Reduction at Low Voltage Switchgear

GE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary.

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

G861 Series Integrated Function. Direct Spark Ignition Control

AR circuit breaker - Hydraulic magnetic,

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

XLM 62V Energy Storage Module

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

Power Break II Switchboard

Programmer Disconnect Accessory Manual for Retrofil CB

Application Engineering

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

LN3 Series Motor and Drives

Bulletin 1489 Circuit Breakers. Selection Guide

G72x Series Direct Spark Ignition Controls

Design considerations for generator set mounted paralleling breakers

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

A1P OPERATING MANUAL

Power Break Circuit Breakers

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

CR193 Vacuum Limitamp* Contactors

Transcription:

GE Zone Selective Interlock Module For GE Circuit Breakers

Table of Contents 1. Introduction... 4 What is Zone-Selective Interlocking (ZSI)?...4 What is a Zone-Selective Interlock Module?...4 2. Description... 5 General...5 Line Side (Upstream) and Load Side (Downstream) Connections...5 Control Power...5 Energy Storage Feature...5 Test Capabilities...5 3. Application Information... 6 Control Power Requirements...6 Max Ambient Temperature...6 Wiring...6 Connections...6 Energy Storage Feature...6 Test Feature How to Apply It...8 Dielectric Testing...9 4. Installing and Connecting the ZSI Module... 10 5. System Coordination Using Zone Selective Interlocking... 11 6. Circuit Description... 13 Zone Selective Interlock Module 2 of 16

Table of Figures Figure 1: Zone Selective Interlock (ZSI Module)... 4 Figure 2: Control Power for Module is Applied from the Left Side of the Enclosure... 4 Figure 3: Wiring Diagram Showing Upstream and Downstream Connections... 7 Figure 4: Interlocking One Upstream Circuit Breaker from Several Zones... 7 Figure 5: Do Not Parallel Circuit Breaker Zone Selective Interlock Inputs... 8 Figure 6: Multi-Zone Interlocking... 11 Figure 7: Zone Selective Interlocking a Double-Ended Substation... 12 Figure 8: Zone Selective Interlock Module Circuit Diagram... 13 Figure 9: Outline Diagram...14 Figure 10: Measurements...14 Zone Selective Interlock Module 3 of 16

1. Introduction What is Zone-Selective Interlocking (ZSI)? ZSI is an optional feature of various GE trip units which allow enhancing protection without sacrificing selectivity between circuit breakers. ZSI adds the capability of sending information from one load-side circuit breaker tier to one or more line-side tiers of circuit breakers so that selectivity is achieved with logic in addition to nested time delays and overcurrent thresholds. What is a Zone-Selective Interlock Module? The zone-selective interlock module is an intermediate control device used between line side (upper tier) and load side (lower tier) circuit breakers to control and distribute the communication signal between the tiers of devices. Circuit breakers that employ ZSI can respond to faults within their immediate zone of protection with minimum delay, while providing appropriately delayed backup protection to zones further downstream from the zones to which they are dedicated. This allows fast protection reducing system stress and arc flash hazard while maintaining the same selectivity that a fully nested and delayed system would have achieved. The traditional means of obtaining selectivity between main circuit breaker and feeder circuit breakers is to set the furthest load side device with the lowest time delays, and increase line side time delays and thresholds. Consequently, the line side portions of the system must withstand high fault current for longer periods of time. Figure 1: Zone Selective Interlock (ZS) Module For further details on ZSI feature and ZSI application please refer DET-1001 Application and Technical Guide; Zone- Selective Interlocking for GE Circuit Breaker and Power Switch s. TIM1 Control Power This document provides information about Zone-Selective Interlock Module to implement ZSI wiring and connections. 120VAC 208/240V AC Ground Stud Figure 2: Control Power for Module is Applied from the Left Side of the Enclosure Zone Selective Interlock Module 4 of 16

2. Description General The ZSI module receives a signal from a load side trip (lower tier) unit which causes the module to transmit a low-level interlock signal to line side trip units (upper tier). The received interlock signal activates the LED portion of an LED-transistor opto-isolator in the line side trip unit causing its ZSI enabled protection to shift from unrestrained mode of operation ( unrestrained time delay) to restrained mode of operation ( restrained time delay). In the case of short time and ground fault protection unrestrained protection should be a shorter time delay band and restrained protection should be a greater delay band. If the receiving trip unit is enabled with Instantaneous ZSI (I-ZSI) the trip unit s instantaneous function will shift from its instantaneous algorithm to an algorithm akin to a fast short-time band. The exact shift of the instantaneous is different based on the circuit breaker platform within which the receiving trip unit is installed. If a trip unit is enabled with threshold ZSI (T-ZSI) the upper tier overcurrent threshold for various protective functions may also shift to a larger threshold. For more detailed information on the application of GE ZSI functions see GE publication DET-1001. Test Capabilities The ZSI module is provided with an integral test means which will provide an indication of: Simple module functionality; Shorted or reverse polarity of the downstream wiring; A proper upstream circuit. Use of the module test means is described in Section 3 (Dielectric Testing). Additional test capabilities are possible with the trip unit and the GE tool kit. For further information on fully testing a ZSI scheme see GE publication DEH-583, Zone-Selective Interlocking Field Testing and Commissioning. Line Side (Upstream) and Load Side (Downstream) Connections Terminals are provided to connect signals from load-side and line-side circuit breakers. Carefully note the polarity and instructions on the label of the ZSI module. See also Section 4, Installing and Connecting the ZSI Module. Control Power Control power for the module is applied via the terminals on the left side of the enclosure. See Figure 2. Energy Storage Feature If a fault occurs, the possibility exists control power may be lost. To ensure the integrity of the signal transmitted to the line -side circuit breakers and to ensure that coordination is not lost, the ZSI module has an energy storage feature that permits follow-through of the interlocking functions if control power is lost. Zone Selective Interlock Module 5 of 16

3. Application Information Control Power Requirements Cat. No. TIM-1: 120/208/240 V ac 50/60 Hz 15 VA maximum Input voltage tolerance: +10%, -15% Note: ZSI Input /Output signal requirement :24VDC, 20ma. tolerance + 10%. (28VDC max) Max Ambient Temperature The ambient temperature surrounding the module should not exceed 85 C. Wiring The wiring for the equipment shall be as follows: 1. Wiring from the circuit breakers to the ZSI module shall be twisted pairs non-shielded, AWG #18-12. A minimum twist configuration of one turn per inch is recommended. 2. Maximum recommended line length (distance between a circuit breaker and the ZSI module) is 1000 feet. 3. Note that downstream/upstream connections require proper observance of polarity. For downstream/upstream connections (signal) use RED for plus. WHITE for minus. 4. The signals being conducted via the downstream/ upstream wiring are low-level signals (dry circuits). It is important, therefore, to ensure that splices are soldered connections (or other approved connections for low power dry circuits); also, if connectors are used, they should be gold-plated terminations. Standard terminal blocks can be used for intermediate connections do not require gold plating. Paralleling is done so that only one set of wires (one twisted pair) is connected to each downstream terminal set at the ZSI module. Wiring is per Section 3 (Wiring) and Figure 3. See Downstream Connections portion of Section 3 (Test Feature How to Apply It) to use the integral test means of the ZSI module as an aid in checking downstream wiring. Upstream Connections (Line Side) In some applications, it may be desirable to interlock an upper tier circuit breaker from more than one ZSI module (e.g. it may be desirable to interlock a main circuit breaker from several separate zones). To accommodate coordination schemes that require this, up to four modules may be connected in parallel to one circuit breaker zone selective INPUT. Two rules that apply to upstream connections are: 1. The upstream connections for several ZSI modules (up to four) may be connected in parallel provided they are terminated in the zone selective INPUT of only one circuit breaker, means this is valid if and only if one upstream breaker is connected as shown in Figure 4. 2. Never parallel the ZSI INPUT connections of circuit breakers provided upstream terminal pair connections must ALWAYS be terminated in the ZSI INPUT of only one trip unit (means one to one mapping or one upstream terminal pair set connection to one trip unit only). See Figure 5. Energy Storage Feature The ZSI module has an energy storage feature which enables it to follow-through with full interlock power should control power to the module be lost simultaneously with the initiation of an interlock signal. Connections Downstream (Load Side) Connections A maximum of 30 zone selective OUTPUTS from lower tier circuit breakers may be connected in parallel provided that: No more than six parallel OUTPUTS are used per downstream terminal set at the ZSI module (e.g. D1; D2; D3; etc.) See Figure 3. Although the module can operate immediately upon application of control power, the energy stored Is not sufficient to fully operate the module unless the module has been energized for one minute prior to the loss of control power. This is applicable whenever control power is removed and then reapplied. Zone Selective Interlock Module 6 of 16

Therefore, if there is a possibility that control power could be lost during the closing of a circuit breaker and coordination of upstream breakers is important during that interval, the control power for the module should be either (1) derived from an independent source, or (2) derived from the line side of an upstream circuit breaker in such a manner that operation of the circuit breakers is delayed by one-minute post control power being available on the line side. May parallel ZSI Output from up to 6 load side CB per load side terminal set ZSI OUTPUT from Load Side CB Twisted Pairs Twisted Pairs D1 D2 D3 D4 D5 ZSI Module (ZSIM) U1 U2 U3 U4 U5 Twisted Pairs ZSI input to upstream CB Do not parallel CB INPUT connections See Figure 5 Wiring is twisted pairs, non-shielded, AWG NO 18-12. Note Polarity! Figure 3: Wiring Diagram Showing Upstream and Downstream Connections Line Side CB ZSIM 1 ZSIM 1 ZSIM 1 ZSIM 1 Load Side Load Side Zone 2 Load Side Zone 3 Load Side Power Bus ZSI Wiring Figure 4: Interlocking One Upstream Circuit Breaker from Several Separate Zones Zone Selective Interlock Module 7 of 16

Test Feature How to Apply It Note: To use within TIM test feature, control power must be applied to the module. Module Functionality The MODULE FUNCTIONAL light will illuminate whenever there is an interlock signal at the DOWNSTREAM CONNECTIONS terminals. This can be simulated manually by pushing the PUSH TO TEST button in the center of the module, thereby proving basic module functionality. Downstream Connections If the MODULE FUNCTIONAL light is illuminated continuously (without pushing the PUSH TO TEST button), one or more of the following problems exist with the downstream circuits: 1. At least one set of wires connected to the DOWNSTREAM CONNECTIONS terminals, D1 through D5 are connected in reversed polarity. 2. Load side wiring is shorted. 3. A trip unit in a load side circuit breaker is defective. To isolate the problem, remove the wires from the DOWNSTREAM CONNECTIONS terminals one at a time, noting when the MODULE FUNCTIONAL light goes out. This will identify the problem circuit. The following checks may be useful in identifying the specific problem: Check for reversed polarity by simply reversing the lead connections from what they were originally and observing whether the MODULE FUNCTIONAL light goes out. Check for shorted downstream wiring by checking between the disconnected wires with an ohmmeter. The Zone Selective Interlock OUTPUT circuit from GE electronic trip unit is essentially an NPN transistor with a reverse diode connected from collector to emitter. To check this circuit for a shorted transistor, check for the forward/ reverse characteristic of the diode with an ohmmeter.! IMPORTANT The open circuit output voltage of the ohmmeter must be less than 15 Vdc if the load side trip unit is connected. Incorrect Wiring Correct Wiring Do not multiple trip unit inputs to one module output ZSIM Outputs from ZSIM wired separately ZSIM From load side CB From Load Side CB Bus Wiring Figure 5: Do Not Parallel Circuit Breaker Zone Selective Interlock Inputs Zone Selective Interlock Module 8 of 16

Upstream Connections You will note that for each set of upstream terminals (U1-U5), an LED is provided between them. When the PUSH TO TEST button is pressed, these LEDs will light if the voltage developed across the upstream circuit is within an acceptable range. Failure of a LED to light is an indication of one or more of the following upstream conditions: 1. Reverse polarity 2. Open circuit 3. Shorted upstream wiring 4. Improper resistivity of the upstream circuit The following checks may be considered for isolating the problem area: Check for reversed polarity by simply reversing the lead connections from what they were originally and observing for the appropriated upstream LED light when the PUSH TO TEST button is pressed. To check for open, shorted, or high-resistance connections in the line side wiring, disconnect the wiring at side from the ZSI module and check the wiring with an ohmmeter. The ZSI module test means may itself be tested by disconnecting the wires from the U1-U5 terminal pair sets and connect 390 Ω ±20% resistor across one of the pair set (positive & negative terminals). The appropriate LED must light when the PUSH TO TEST button is pressed. Note: If all connections to upstream terminal pair sets U1-U5 are open (not connected) the five LED indicators may light without pushing the PUSH TO TEST button. This is not an abnormal condition but a valid test of the upstream circuits will always be obtained when U1-U5 terminals are properly connected which means PUSH TO TEST button is activated. Allow the module to be energized with rated control power for a minimum of one minute. Interrupt control power and immediately push the PUSH TO TEST button. The MODULE FUNCTIONAL light must come on for at least one-third of a second (a long blink). Allow at least one-minute charge time before repeating the test. Failure to achieve the above noticeable time delay will require the energy storage capacitor be replaced. Dielectric Testing CAUTION Indicates that if the hazard is not avoided could result in minor or moderate injury. The ZSI module may be tested at 1500 Vac for one minute or 1650 Vac for one second, between all upstream, all downstream, all control power terminals shorted together (inclusively), and the ground stud. In other words, every terminal on the ZSI module (except the ground stud) shall be shorted together and the potential applied between that point and the ground stud. Under the above test conditions, the test current should not exceed 500 micro-amperes. CAUTION 1. Do not test between individual terminals and ground 2. Do not test between downstream/upstream terminals 3. All terminals must be shorted together! Testing the Energy Storage Feature As described in Section 3 (Energy Storage Feature) the ZSI module has an energy storage feature that allows follow-through of the interlocking function if a fault causes a simultaneous loss of control power to the module. Energy storage is achieved via an electrolytic capacitor which will may lose capacitance over an extended period of time. Thus, it is advisable to perform the following in-service check every 6-12 months and whenever additional upstream circuits are connected (added) to terminals U1-U5. Fusing Recommended control power input fusing is 0.5 amperes, 250v (Littlefuse 312.500) or equivalent. Zone Selective Interlock Module 9 of 16

4. Installing and Connecting the ZSI Module To Install and connect the ZSI module, proceed as follows: Read the application information (Section 3). Wire the module in accordance with Section 3 (Wiring) and Figure 3. Torque terminals to 20 in-lbs. Connect control power. See label on the left side of the ZSI module. Refer also to Figure 2. For dc versions, note polarity. Note that filtered direct current must be used. Also, refer to Section 3 (Control Power Requirements). Follow the instructions on the face of the ZSI module regarding connections. Pay particular attention to the polarity and nomenclature (i.e. downstream connections go to the OUTPUT of the trip units; upstream connections go to the INPUT of the trip units). Use the integral test means of the ZSI module to check downstream and upstream connections. See Section 3 (Test Feature How to Apply It). Zone Selective Interlock Module 10 of 16

5. System Coordination Using Zone Selective Interlocking Zone selective interlocking can be a valuable tool in achieving efficient system protection and coordination. To apply it effectively requires a thorough understanding of what zone selective Interlocking is and the proper application to a strategic plan of system protection. As with any plan, the system is best protected when there is a thoughtful strategic plan which factors in significant variables and contingencies. Tier 0 CB Source It is beyond the scope of these instructions to attempt a detailed discussion of coordination schemes. Figure 6 and 7 shown only in the interests of illustrating examples of two basic applications of ZSI module. Tier 1 CB ZSIM 1 Figure 6 is a simple example of multiple zone interlocking. If a fault occurs, each breaker will interlock the breaker immediately upstream from it. Tier 2 CB ZSIM 2 Figure 7 is an example of double ended substation with tie circuit breaker, feeding two banks of load side feeder circuit breakers. Note that ZSI module NO.1 interlocks both mains and the tie circuit breaker for the occurrence of a fault on the load side of the feeder circuit breaker (Zone 2). Tier 3 CB ZSIM 3 ZSI module NO.2 is an option which provides coordination between the tie circuit breaker and the main circuit breaker (i.e., the TIE will trip first in the event of a bus fault in Zone 1. Without ZSI module NO.2, a bus fault in Zone 1 would probably cause tripping of both the tie and the main circuit breakers. Motor L1 L2 OUTPUT from INPUT to Load Side Connections ZSIM Line Side Connections Bus Wiring Figure 6: Multi-zone Interlocking Zone Selective Interlock Module 11 of 16

Source No 1 Source No 2 ZSIM 2 Main No 1 Main No 2 ZSIM 3 THE BREAKER Zone 1 ZSIM 1 Trip Unit Trip Unit Trip Unit Trip Unit Trip Unit Trip Unit Trip Unit Trip Unit Zone 2 Bus Wiring OUTPUT from INPUT to Upstream Connections ZSIM Downstream Connections Figure 7: Zone Selective Interlocking a Double-ended Substation Zone Selective Interlock Module 12 of 16

6. Circuit Description The following is a brief circuit description of the ZSI module. See Figure 8 for the circuit diagram. The DOWNSTREAM CONNECTIONS consist of five separate terminal sets, each set providing a voltage reference input via a resistor divider network to a voltage comparator. This voltage reference is compared to a second internal comparator reference. When the voltage at the DOWNSTREAM CONNECTIONS is higher than the comparator reference there is no output at the UPSTREAM CONNECTIONS of the module. The window detectors sense the voltage across each of the five terminal sets for UPSTREAM CONNECTIONS and will illuminate an LED if the voltage across its terminal set is within an acceptable voltage window. Therefore, the window detectors, (with their associated LED) serve to indication that a proper upstream circuit exists. The PUSH TO TEST button is a means by which a downstream interlock signal can be simulated, thereby providing a test method for module functionally and proper upstream circuitry. When an interlock signal (Logic O) is received at any of the downstream terminals, the comparator will go high. This actuates the electronic switch and provides and output voltage at all UPSTREAM CONNECTIONS; the output from the electronic switch will also illuminate the MODULE FUNCTIONAL LED. Load Side Connections Voltage Comparators Electronic Switch Line Side Connections Reference Reference Reference Reference Reference Window Detectors Push to Test Reference Functional Module LED Display Figure 8: Zone Selective Interlock Module Circuit Diagram Zone Selective Interlock Module 13 of 16

Note: All dimensions are in inches Figure 9: Outline Diagram 6.62 5 4.5 3.86 REF 0.7 1 4.5.203 dia hole 6.5 Note: All dimensions are in inches Figure 10: Dimensions Zone Selective Interlock Module 14 of 16

For additional information on ZSI application and testing see GE publications: DEH-583 Instruction Guide; Zone-Selective Interlocking Field Testing and Commissioning for EntelliGuard* and microentelliguard* s DET-1001 Application and Technical Guide; Zone-Selective Interlocking for GE Circuit Breaker and Power Switch s DEE-689 Toolkit User Guide DEE-688 Toolkit Installation Instructions Marcelo E. Valdes & John J. Dougherty; Advances in Protective Device Interlocking for Improved Protection and Selectivity; Industry Applications, IEEE Transactions on; Vol. 50, Issue 3, Pgs. 1639-1648, yr. 2014 For additional information on mitigating arc flash incident energy with circuit breaker protection and instantaneous selectivity see: DET-760D Application and Technical Guide; Guide to Instantaneous Selectivity DET-1002 Application and Technical Guide; 2017 National Electric Code Updates, NEC 240.87 Arc Energy Reduction, for Circuit Breakers & NEC 240.67 Arc Energy Reduction, for Fusible Switches DET-1004 Application and Technical Guide; Energy Reducing Maintenance Switch Marcelo E. Valdes. Steve Hansen & Peter Sutherland; Optimized Instantaneous Protection Settings; IEEE Industry Applications Magazine, pgs. 66-73, May/June 2012. User Manual for the EntelliGuard TU trip units: DEH-4567 EntelliGuard TU s Installation, Operation, and Maintenance Manual Zone Selective Interlock Module 15 of 16

Imagination at work GE 41 Woodford Avenue Plainville, CT 06062 www.geindustrial.com *Registered trademark of the General Electric Company. The GE brand, logo, and lumination are trademarks of the General Electric Company. 2018 General Electric Company. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. DET-1047, Rev. 11/2018