EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

Similar documents
Split-Sky Air FDYP-B7 Concealed Ceiling Unit

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

Split-Sky Air FAYP-B Wall Mounted Unit

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXS-K

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Air Conditioners Technical Data

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Air Conditioners. Technical Data UATYQ-CY1

Air Conditioning. Technical Data EEDEN RXZ-N

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

Air Conditioning. Technical Data EEDEN RXZ-N

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

Air Conditioning. Technical Data EEDEN RXJ-L

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems MXS-B Multi Application Split Sky Air

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB

EWAD-CZ EWAD-CZ. Inverter driven air-cooled chiller. ESEER up to 5.4. Inverter driven single screw compressor. Multiple efficiency and sound versions

Split-Sky Air RMX-JZ Super Multi Plus

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

UATYQ-ABAY1. Air Conditioning Technical Data > UATYQ20ABAY1 > UATYQ25ABAY1 > UATYQ30ABAY1 > UATYQ45ABAY1 > UATYQ50ABAY1 > UATYQ55ABAY1

your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3

Outdoor Units R-410A ARX-GV1B

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units

Air Conditioning Technical Data RZQSG-L3/9V1

Technical Data. Air Conditioners

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

EEDEN technical data. Applied Systems. Centrifugal Fan EUWAC5-10FZW

Applied Systems. Technical Data. Concealed ceiling unit EEDEN FWP-AT

A2P H2P H4P H6P H1P H3P H5P H7P. Outdoor X205A OFF Y1E E1H R6T X5A F8U F7U K14R K2R X28A X6A SEE NOTE 7 HAP X77A X31A X13A X21A P< S1PL P> S1PH

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

Air-Cooled Liquid Chiller with integrated hydraulic module

Product. ortfolio RESIDENTIAL & LIGHT COMMERCIAL

Air Conditioning. Technical Data. VRV IV water cooled series EEDEN RWEYQ-T8

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

Ceiling Concealed Chilled Water Fan Coil Unit

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

High Wall Type ( 2 Series )

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

CDK25JVEC, CDK35JVEC, CDX25BVMC, CDX25BVMC9, CDX25JVEC, CDX35BVMC, CDX35BVMC9, CDX35JVEC, CDX50AVMC9, CDX60AVMC9 CDK35HAVER1, CDK60HAVER1

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

FFQN-C, FCRN-E, FFRN-C

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

Vertical Air Handling Unit type

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Technical Sales Guide # 040 YDFC 0 1 Page 2

Technical Service Manual

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

VHIA High-Static Ducted Indoor Units - 60HZ

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

Low Static Pressure Duct(V shape evaporator)

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

/ LOSSNAY / LGH-RS2-E2

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

SERVICE MANUAL OUTDOOR UNIT. No. OB386

D M S 760 C01 A A 1 1

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Fan Coil Units. Technical Data

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Air Cooled Packaged Units

AHN 064 to 304 EHN/CHN 064 to 304

CENTRIFUGAL FAN COIL UNIT VCE

Digital Inverter 4 series

WCA4**4. Product Specifications

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

MSP Duct S Specifications

IDENTIFICATION ACCESSORIES DESCRIPTION

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

Low Static Pressure Duct (V shape evaporator)

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Transcription:

EEDEN08-00 technical data FDQ-B8V3B9 air conditioning systems Split Sky Air

Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Het ISO400 assures an effective environmental management system in order to help protect human health and the environment from potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.. Daikin units comply with the European regulations that guarantee the safety of the product. Naamloze Vennootschap Zandvoordestraat 300 B-8400 Ostend, Belgium www.daikin.eu BTW: BE 042 20 336 RPR Oostende Daikin Europe N.V. participates in the Eurovent Certification Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certified data of certified models are listed in the Eurovent Directory. EEDEN08-00 EEDEN08-00 - 02/2008 Printed in Belgium by Goekint Graphics Copyright Daikin

EEDEN08-00 technical data FDQ-B8V3B9 air conditioning systems Split Sky Air

TABLE OF CONTENTS FDQ-B8V3B9 Features............................................................. 5 2 Specifications....................................................... 6 For indoor units only................................................. 6 Technical Specifications............................................. 6 Electrical Specifications............................................. 7 3 Options.............................................................. 8 4 Control systems.................................................... 9 5 Dimensional drawing & centre of gravity....................... 0 Dimensional drawing................................................ 0 6 Piping diagram..................................................... 7 Wiring diagram..................................................... 2 Wiring diagram...................................................... 2 8 Sound data......................................................... 3 Sound pressure spectrum........................................... 3 Sound power spectrum............................................. 4 9 Fan characteristics................................................ 5 0 Installation.......................................................... 6 Installation method.................................................. 6 Split Sky Air Indoor Units 4

t i y n k 3 r 8t o 0 i o - ld 4 np - FI Features 9 BU S V a B Q D RS Slim design for flexible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Maximum external static pressure (ESP) ranges from 50 till 250Pa Optimum air distribution heat pump standard optional 2 steps: FDQ250, 3 steps: FDQ25,200 optional 5 Split Sky Air Indoor Units

2 Specifications 2- FOR INDOOR UNITS ONLY FDQ25B8V3B9 FDQ200B8V3B9 FDQ250B8V3B9 Nominal input (Indoor only) Cooling kw,340,340 Heating kw,340,340 2-2 TECHNICAL SPECIFICATIONS FDQ25B8V3B9 FDQ200B8V3B9 FDQ250B8V3B9 Casing Colour Non painted Material Galvanised steel Dimensions Packing Height mm 52 607 607 Width mm,55 Depth mm 795,055,055 Unit Height mm 350 450 450 Width mm,400 Depth mm 662 900 900 Weight Unit kg 59.0 89.0 94.0 Packed Unit kg 74.0 08.0 3.0 Required Ceiling Void mm 350 450 450 Heat Dimensions Length mm,50,200,200 Exchanger Nr of Rows 3 3 3 Fin Pitch mm.75 2.00 2.00 Nr of Passes 0 2 2 Face Area m² 0.338 0.634 0.634 Nr of Stages 4 24 24 Tube type Hi-XSS (7) Hi-XSS (8) Hi-XSS (8) Fin Type Rhombus Non-symmetric fin Non-symmetric fin Treatment Hydrophilic Fan Type Sirocco fan Quantity 2 2 2 Air Flow Rate Cooling Medium m³/min 43.0 69.0 89.0 Heating Medium m³/min 43.0 69.0 89.0 Fan Max High Pa 50 250 250 Standard Pa 50 250 250 Low Pa 50 250 250 Motor Quantity Model DPA26-78NB DPC24-24NB DPC24-24NB Number of steps 3 3 2 Output W 500 650,000 (high) Drive Direct drive Cooling Sound Power Medium dba 75.0 8.0 82.0 Sound Pressure High dba 44.0 45.0 47.0 Heating Sound Pressure Low dba 44.0 45.0 47.0 Refrigerant Type R-40A Piping Liquid (OD) Type Flare connection connections Diameter mm 9.52 9.52 2.7 (OD) Gas Type Flare connection Braze connection Braze connection Diameter mm 5.9 22.2 22.2 (OD) Drain Diameter mm 25 25 (OD) Heat Insulation Both liquid and gas pipes Air Filter Resin net with mold resistance Air direction control Up and downwards Temperature control Microprocessor thermostat for cooling and heating Safety Devices Fan motor thermal fuse Standard Item Installation and operation manual Accessories Quantity 3 2 Split Sky Air Indoor Units 6

2 Specifications 2 2-2 TECHNICAL SPECIFICATIONS FDQ25B8V3B9 FDQ200B8V3B9 FDQ250B8V3B9 Notes Sound values are measured in a semi-anechoic room with corrections The sound pressure level is measured via a microphone at m distance of the unit. Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings of this chapter. The sound power level is an absolute value indicating the power which a sound source generates. 2-3 ELECTRICAL SPECIFICATIONS FDQ25B8V3B9 FDQ200B8V3B9 FDQ250B8V3B9 Power Supply Name V3 Phase ~ Frequency Hz 50 50 50 Voltage V 230 230 230 Voltage range Minimum -0% Maximum +0% Power Supply Intake Both indoor and outdoor unit Notes FOR MORE DETAILS, REFER TO WIRING DIAGRAM, NAME PLATE AND INSTALLATION MANUAL 7 Split Sky Air Indoor Units

3 Options FDQ-B7V3B Name of option FDQ25-200-250B7 Wiring adaptor for electrical appendices KRP4A5 Adapter for wiring (interlock for fresh air intake) KRPB54 Interface adapter for Sky Air series DTA2B5 Central remote control DCS302C5 unified ON/OFF control DCS30B5 Schedule timer DST30B5 Option PCB for electrical heater, humidifier and/or hour meter. * EKRPB2 Remote control Wired type BRCD527 Remote ON/OFF, forced OFF EKRORO 3 3 3TW22809-F * Electrical heater, humidifier and hour meter are field supply. These parts should not be installed inside the equipment. (Refer to installation manual EKRPB2). Split Sky Air Indoor Units 8

4 Control systems BRCD52 4 5 x 0 (Round end slit) 6.5x9(Roundendslit) Cover closed 5 x 7 (Round end slit) HoleJ5 Cover open 3TW2365-2 9 Split Sky Air Indoor Units

5 Dimensional drawing & centre of gravity 5 - Dimensional drawing FDQ25B unit (mm) View A 3 5 View A j j2 j3 j4 j5 Power supply intake Drain connection J25 O.D. Gas pipe connection single union joint 5/8 or 5,9 mm Liquid pipe connection single union joint 3/8 or 9,52 mm Filter Notes: R : Service space 3TW30824- FDQ200-250B FDYP200-250B unit (mm) View A View A j j2 j3 j4 j5 Power supply intake Drain connection J25 O.D. Gas pipe connection FDYP200B/250B : /8 O.D. or 28,6 mm FDQ200/250 :7/8 O.D. or 22,2 mm O.D. Liquid pipe connection FDYP200B : Single union joint /2 or 2.7mm FDYP250B : Single union joint 5/8 or 5.9mm FDQ200 : Single union joint 3/8 or 9,52 mm FDQ250 : Single union joint /2 or 2.7mm Filter Notes: R : Service space Model A B FDYP200B8V9/FDQ200B8V3B9 830 285 FDYP250B8V9/FDQ250B8V3B9 890 255 3TW30844- Split Sky Air Indoor Units 0

6 Piping diagram 6 FDQ25-250B Heat exchanger Cooling Heating Refrigerant flow Refrigerant pipe connection port diameters Model Gas Liquid FDQ25 J5.90 J9.52 FDQ200 J 22.2 FDQ250 J 2.7 Liquid pipe connection port Gas pipe connection port O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe 3TW26055-A Split Sky Air Indoor Units

7 Wiring diagram 7 - Wiring diagram FDQ25-250B 3 Notes. When using the central remote control, see manual for connection to the unit. 2. Be sure that the power supply is switched off before opening the switch box. * L-tap is not available for 250 class. Outdoor Indoor Wired remote control 7 g Field wiring D Terminal a : Connector c : Wire clamp b : Protective earth (screw) Colours BLK: Black / BRN: brown / WHT: White RED: Red / BLU: Blue / GRY: Grey ORG: Orange / YLW: Yellow Details of wired remote control (optional accessory) Terminals for operation indicator Fan operation compressor operation Switch box Remote ON/OFF, forced OFF Adapter for wiring AP Printed circuit board A3P Printed circuit board TR Transformer(230V / 28V) CR Capacitor (fan) FT Thermal fuse (MF embedded) HAP Light emitting diode (service monitor green) KF Magnetic contactor (MF) MF Motor (Fan) RT R2T RyF SS XM RC TC F5U QDI Thermistor (air) Thermistor (coil) Magnetic relay (fan) Selector switch (emergency) Terminal strip Signal receiver circuit Signal transmission circuit Power setting fault Earth leakage breaker Wired remote control BS On/Off button BS2 Timer mode start/stop button BS3,BS8 Programming time button BS4 Temperature setting button up BS9 Temperature setting button down BS6 Operation mode selector button BS7 Timer on/off button BS2 Inspection/test operation button BS4 HP LCD SS Filter sign reset button Light emitting diode (service monitor red) Liquid crystal display Selector switch (main/sub) Adapter for wiring RyC,RyF Magnetic relay Connector for optional parts X60A Connector (interface adaptor for SKY AIR / X6A US series) X33A Connector (adapter for wiring) X35A Connector (group control adapter) X40A Connector (remote ON/OFF, forced off, only SKY-AIR Pàseries) 2TW26036-B Split Sky Air Indoor Units 2

8 Sound data 8 - Sound pressure spectrum FDQ200B 8 Sound pressure level (db) FDQ25B Legend Sound pressure level (db) High speed Low speed 3TW2287- NOTES Octave band center frequency (Hz) 3TW22807- NOTES Octave band center frequency (Hz) Data is valid at free field condition 2 Data is valid at nominal operation condition (at 62 Pa ESP, 90m 3 /min) 3 db(a) = A-weighted sound pressure level (A-scale according to IEC) 4 Reference acoustic pressure 0dB = 20μPa 5 the indicated sound pressure is the casing radiated sound pressure. Data is valid at free field condition 2 Data is valid at nominal operation condition (50 Pa ESP, 72m 3 /min) 3 db(a) = A-weighted sound pressure level (A-scale according to IEC) 4 Reference acoustic pressure 0dB = 20Pa 5 the indicated sound pressure is the casing radiated sound pressure. Metalducts insulated inside Suction Unit discharge Microphone Location of microphone FDQ250B Sound pressure level (db) 3TW22827- NOTES Octave band center frequency (Hz) Data is valid at free field condition 2 Data is valid at nominal operation condition (62 Pa ESP, 90m 3 /min) 3 db(a) = A-weighted sound pressure level (A-scale according to IEC) 4 Reference acoustic pressure 0dB = 20Pa 5 the indicated sound pressure is the casing radiated sound pressure. Metalducts insulated inside Suction Unit discharge Microphone Location of microphone 3 Split Sky Air Indoor Units

8 Sound data 8-2 Sound power spectrum FDQ25B FDQ200B 3 Sound operation level (db) Sound operation level (db) 8 3TW26057- NOTES Octave band center frequency (Hz) 3TW26957- NOTES Octave band center frequency (Hz) Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba A-weighted sound operation level. (A-scale according to IEC) 4 Reference acoustic pressure 0dB = 20Pa 5 Curve for FDQ25B in cooling mode Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba A-weighted sound operation level. (A-scale according to IEC) 4 Reference acoustic pressure 0dB = 20Pa 5 Curve for FDQ200B in cooling mode FDQ250B Sound operation level (db) 3TW26967- NOTES Octave band center frequency (Hz) Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba A-weighted sound operation level. (A-scale according to IEC) 4 Reference acoustic pressure 0dB = 20Pa 5 Curve for FDQ250B in cooling mode Split Sky Air Indoor Units 4

9 Fan characteristics FDQ25B FDQ200B 9 low medium high low medium high 3TW22808-3TW2288- FDQ250B high medium 3TW22828-5 Split Sky Air Indoor Units

0 Installation 0 - Installation method 3 0 Number Description Indoor unit 2 Outdoor unit 3 Remote control 4 Inlet air 5 Discharged air 6 Refrigerant piping, connection electric wire 7 Drain pipe Ground wire 8 Wire to ground from the outdoor unit to prevent electrical shocks. 9 Air filter Split Sky Air Indoor Units 6

0 Installation 0 - Installation method 0 7 Split Sky Air Indoor Units