Technical Information Liquiline System CAT810

Similar documents
Technical Information Cleanfit Control CYC25

Flowfit CYA251. Technical Information. Flow assembly for nitrate/sac, turbidity and oxygen sensors

Technical Information Cleanfit CPA451

Operating Instructions CYR52

Technical Information Ceraliquid CPS41D and CPS41

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors

Soliswitch FTE20. Technical Information. Point level switch for granular solids

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Ceraliquid CPS42/CPS42D/CPS43

Orbisint CPS12/CPS12D/CPS13

Technical Information Cleanfit CPA472D

Orbipore CPS91 and CPS91D

Technical Information Cleanfit CPA875

Conductivity Measurement CLM 280

Differential Pressure Sensors

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Positive displacement batch controller

Differential pressure sensor

Technical Information Cleanfit CPA871

Operating Instructions Flexdip CYA112

Model DS1000/DT20 System

POB series Coil Tester & Power Supply Units

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

Insertion magnetic inductive flowmeter

POB series Coil Tester & Power Supply Units

High Performance Axial Fans

Installation Instructions

Differential Pressure Switch QBM81-

Differential Pressure Sensors

Condensation monitor

Horizontal Pre-Piped Bladder Tanks with Proportioner

Table of Contents - Vangard Filters

Vertical Pre-Piped Bladder Tanks with Proportioner

Preinstallation Requirements for Avanti J Series Centrifuges

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Operating Instructions. Compressed air cleaning unit VAC BA00498C/07/EN/

Pressure Sensors. for liquid and gaseous media

Differential Pressure Sensors

MGE TM Galaxy TM 7000

Paddle-wheel flow controller for On/Off control

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

500 / 630 / 720 / 760 / 800 / 850 / 900

M-50/55 Series. Fixed setting flow switch with in-line flow

LCMass Series Mass Flow Sensor

Mini Pressure Transmitter HA7

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Differential Pressure Sensors

Green Power 2.0 MASTERYS GP

Blue e+ chillers with the principle

IONIZATION SOLUTIONS

Stamolys CA71AM. Technical Information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

These documents contain additional information concerning related products from Rockwell Automation.

BILGE WATER DEOILING SAFE, RELIABLE, ECONOMICAL MULTI-PHASE EMULSION BREAKER MPEB

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

MGE TM Galaxy TM 7000 GFC

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Safety Standards. Model Number:

Ceraliquid CPS41 and CPS41D

Level Measurement Point level measurement - RF Capacitance switches

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Level Sensor with G1/2" Thread Hygienic

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

Level Sensor with M12 Thread Hygienic

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Orbisint CPS11 and CPS11D

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

AutoFilt RF3 Automatic Self-Cleaning Filter

HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3

3. Operating instructions: Minor 200

ELEMENT. Product family datasheet. Constant Voltage Non dimmable

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

Material Specification PVC valves shall meet ASTM D1784 cell classification 124 standards. CPVC valves shall meet ASTM D1784 cell classification 23447

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Type Electrically Actuated Ball Valve

GETTING STARTED GUIDE NI AO, ±10 V, 16 Bit, 25 ks/s/ch Simultaneous

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

Model MTB-ASME Vertical Pre-Piped Bladder Tanks

Type Electrically Actuated Ball Valve

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

AutoFilt RF3 Automatic Self-Cleaning Filter

NI 9251 with mini XLR

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

OPTIFLUX 6000 Technical Datasheet

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Stamolys CA71SI. Technical Information

Differential Pressure Switch QBM81-

Transcription:

TI01138C/07/EN/02.16 71341422 Products Solutions Services Technical Information Control of sample preparation by the Liquiline System CA80 or a time control system Automatic sample preparation system for supplying process measuring devices with filtered samples from pressure pipes Application enables the fully automatic collection and filtration of aqueous samples. Thanks to the modular concept, the sample preparation system can be adapted to various different process conditions. There are various order options available for this purpose. The sample preparation system can be optionally installed on a mounting plate or in the analyzer stand of a CA80 analyzer. The device is designed for use in the following applications: Secondary clarification of communal and industrial purification plants Collection of aqueous samples from industrial processes Your benefits Robust and reliable: Optional water or compressed air backflushing function for the filter Simple and user-friendly: Control via a CA80 analyzer Alternatively via a time control function Cleaning and maintenance: Removal of filter without using tools Flexible: Modular filter system Accessories for a range of installation conditions

Table of contents Function and system design... 3 Function... 3 Measuring system... 3 Installation examples... 3 Functioning with control via Liquiline System CA80 analyzer... 5 Functioning with time control system... 5 Accessories... 12 Communication and data processing... 6 Controller... 6 Dependability... 6 Reliability thanks to Memosens technology... 6 Maintainability... 7 Power supply... 7 Electrical connection of the optional cleaning valve... 7 Supply voltage... 7 Power consumption of optional cleaning valve... 7 Performance characteristics... 8 Sampling methods... 8 Installation... 8 Installation instructions... 8 Environment... 9 Ambient temperature range... 9 Storage temperature... 9 Humidity... 9 Degree of protection... 9 Electromagnetic compatibility... 9 Electrical safety... 9 Degree of contamination... 9 Process... 9 Sample temperature... 9 Process pressure... 9 Pressure for optional automatic cleaning... 9 Process connection... 9 Mechanical construction... 10 Dimensions... 10 Weight... 10 Materials... 10 Certificates and approvals... 11 mark... 11 EAC... 11 Ordering information... 12 Product page... 12 Product Configurator... 12 Scope of delivery... 12 2 Endress+Hauser

Function and system design Function Measuring system The enables the fully automatic collection and filtration of aqueous samples. The static and dynamic pressure in the process bypass cause the sample to pass through the filter. The filtrate line is connected to the collecting vessel of the downstream analyzer. A complete sample conditioning system comprises: including filter, with the following depending on the version: Cleaning valve Vent valve Drain valve Mounting plate Sample hose to analyzer Installation examples 3 1 2 1 CAT810, basic version A0029445 2 CAT810 installed on a mounting plate with cleaning valve and drain valve as optional extras 1 Cleaning valve 2 Drain valve 3 Time control system A0029446 Endress+Hauser 3

1 2 3 6 5 4 3 CAT810 installed in the tower housing with cleaning valve, drain valve and vent valve 1 Outlet 2 Vent valve 3 Analyzer stand 4 Inlet 5 Drain valve 6 Cleaning valve A0029449 1 10 9 8 7 2 3 6 5 4 4 A0029451 with cleaning valve connected to Liquiline System CA80 1 Liquiline System CA80 2 Sample collecting vessel overflow 3 Sample 4 Cleaning valve 5 Inlet pipe for pressurized sample 6 Filter unit 7 Purge connection (compressed air or water) 8 9 Time control system (optional) 10 Overflow 4 Endress+Hauser

Functioning with control via Liquiline System CA80 analyzer Functioning with time control system The sample preparation system enables automatic filter backflushing and the configuration of different backflush intervals, controlled via the Liquiline System CA80. All media-bearing parts can be removed and cleaned without tools. The time-controlled sample preparation system enables the configuration of different backflush intervals. All parts in contact with medium can be removed without tools and cleaned. Endress+Hauser 5

Communication and data processing Controller The sample preparation system is controlled by a Liquiline System CA80. The sample preparation system is configured using the display and operating elements of the analyzer. Version with time control function: The time control function makes it possible to set the cleaning time and the cleaning interval. Dependability Reliability thanks to Memosens technology Memosens MEMO SENS Memosens makes your measuring point safer and more reliable: Non-contact, digital signal transmission enables optimum galvanic isolation Completely watertight Sensor can be calibrated in a lab, thus increasing the availability of the measuring point in the process Intrinsically safe electronics mean operation in hazardous areas is not a problem. Predictive maintenance thanks to recording of sensor data, e.g.: Total hours of operation Hours of operation with very high or very low measured values Hours of operation at high temperatures Number of steam sterilizations Sensor condition 6 Endress+Hauser

Maintainability Modular design The sample preparation system can be adapted to suit your needs: Retrofitting the cleaning valve Retrofitting the vent valve Power supply Electrical connection of the optional cleaning valve Supply voltage --> For detailed wiring diagram, see Operating Instructions for the 100 to 120 V AC / 200 to 240 V AC 50 or 60 Hz NOTICE The device does not have a power switch The customer must provide a protected circuit breaker in the vicinity of the device. The circuit breaker must be a switch or power switch, and you must label it as the circuit breaker for the device. Power consumption of optional cleaning valve Max. 30 VA Endress+Hauser 7

Performance characteristics Sampling methods Depending on version: Program-controlled ( Liquiline System CA80 control unit) Time-controlled Installation Installation instructions Mounting conditions Correct The inlet pipe (6) must be routed with a downward gradient to the sampling point. Incorrect The inlet pipe (6) must never be routed with an upward gradient to the sampling point. Note the following when erecting the device: Make sure that the fluid can drain freely, or use the optional vent valve Installation in a horizontal pipe is advisable. Do not install in a vertical pipe Avoid siphoning effects in the sample line. 8 Endress+Hauser

Environment Ambient temperature range Storage temperature Humidity Degree of protection Electromagnetic compatibility Electrical safety +5 to +40 C (41 to 104 F) -20 to +60 C (-4 to 140 F) 10 to 95%, not condensing IP65 Interference emission and interference immunity as per EN 61326-1:2006, class A for industrial sectors IEC 61010-1, Class I equipment Low voltage: overvoltage category II Environment < 2000 m (< 6562 ft) above MSL Degree of contamination The product is suitable for pollution degree 2. Process Sample temperature Process pressure Pressure for optional automatic cleaning Process connection 4 to 40 C (39 to 104 F) 1.5 to 4.0 bar (21.76 to 58.01 psi) 2.0 to 5.0 bar (29.0 to 72.5 psi); but at least 0.5 bar (7.3 psi) > process pressure The sample preparation system is designed for mounting on pipework. Suitable process connections must be available for this. The sample preparation system is available with the following process connections: Inlet External thread G2", straight Hose nozzle OD 30 mm, straight Adhesive fitting, ID 40 mm, straight Procedure External thread G2", straight Hose nozzle OD 30 mm, 90 Adhesive coupling, ID 40 mm, 90 Endress+Hauser 9

Mechanical construction Dimensions 811 (31.93) 870 (34.25) 303 (11.93) 131 (5.16) 350 (13.78) 177 (6.97) A0029453 A0029454 5 CAT810 basic version, dimensions in mm (in) 6 CAT810 version with mounting plate, dimensions in mm (in) 828 (32.60) 327 (12.87) 327 (12.87) 7 A0029455 CAT810 version for analyzer stand, dimensions in mm (in) Weight Order version Weight Basic version Installed on a mounting plate Installed on a mounting plate, time control for cleaning valve Prepared for a CA80 analyzer stand 1 kg (2.2 lbs) 4 kg (8.8 lbs) 6 kg (13.2 lbs) 2 kg (4.4 lbs) Materials Parts not in contact with medium Mounting plate PVC 10 Endress+Hauser

Parts in contact with medium Pipes Cleaning valve Seal Drain valve Glue Vent valve PVC PP EPDM PVC Tangit PVC Certificates and approvals The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EU directives. The manufacturer confirms successful testing of the product by affixing to it the mark. mark EAC The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EU directives. The manufacturer confirms successful testing of the product by affixing to it the mark. The product has been certified according to guidelines TP TC 004/2011 and TP TC 020/2011 which apply in the European Economic Area (EEA). The EAC conformity mark is affixed to the product. Endress+Hauser 11

Ordering information Product page Product Configurator www.endress.com/cat810 On the product page there is a "Configuration" button to the right of the product image. 1. Click this button. The Configurator opens in a separate window. 2. Select all the options to configure the device in line with your requirements. In this way, you receive a valid and complete order code for the device. 3. Export the order code as a PDF or Excel file. To do so, click the appropriate button on the right above the selection window. For many products you also have the option of downloading CAD or 2D drawings of the selected product version. To do so, click the "CAD" tab and select the desired file type using dropdown lists. Scope of delivery The scope of delivery comprises: 1 in the version ordered 1 copy of the Operating Instructions (in the desired language on selection of the order option) 1 CD-ROM with Operating Instructions in all available languages Optional accessories Accessories The following are the most important accessories available at the time this documentation was issued. For accessories not listed here, please contact your service or sales office. Cleaning valve 200 to 240 V AC, 50/60 Hz Order No. 71222748 Cleaning valve 100 to 120 V AC, 50/60 Hz Order No. 71223912 CAT810 kit: inlet pipe with cock, basic, panel Order No. 71251165 CAT810 kit: inlet pipe without cock, basic, panel Order No. 71251167 CAT810 kit: vent valve, base, basic, panel Order No. 71251168 12 Endress+Hauser

www.addresses.endress.com