Low Profile J Series Power Unit with Vane Pump

Similar documents
Operating Instructions & Parts Manual

Operating Instructions & Parts Manual

Rancher Hydraulic Chute Owner s Manual.

Installation and Operating Manual

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Eurovacuum Installations and Operating manual EV Series Vacuum pumps Models

Standard Power Units Start-Up and Maintenance

MID RISE. INSTALLATION and OPERATION MANUAL MODEL 6000A // 6000E 6,000 LB. CAPACITY. READ and SAVE THIS INSTRUCTION MANUAL

H2000 Hydraulic Chute

SPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection

CIRCLE SEAL CONTROLS

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , ,

OPERATION AND PARTS MANUAL

JARVIS. Model HTC -80 Hog Toe Cutter

6L Oil-less Air Compressor 53103

END SUCTION CENTRIFUGAL PUMPS

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

Under Axle Jack Max. Capacity: 25 Tons

Dodge Cool Lube 2 for Sleevoil Pillow Blocks Part Numbers , , ,

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

CIRCLE SEAL CONTROLS

Operating instructions Form no safety definitions

STAR STOP SHALLOW WELL JET PUMP

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

M-3025CB-AV Fuel Pump

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

Installation & Operator s Manual

TABLE OF CONTENTS. 1. Before You Begin 3 Disclaimer 3 What Is Included 3 Optional Accessories 3 Unpacking Instructions 3 Claims 3 Contact Us 3

SHALLOW WELL JET PUMP

JARVIS. Model 30CL-1 AND 30CL-3 Hock Cutter and Dehorner. 30CL-1 Hock Cutter

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

LAWN SPRINKLER, IRRIGATION PUMP

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

SELF PRIMING CHEMICAL SERVICE PUMPS

Excellence In Fluid Control Since 1975

Installation & Operator s Manual

PRE-PLUMBED SEWAGE SYSTEM

INSTALLATION & OPERATING INSTRUCTIONS

8 LIFT ASSEMBLY 8.1 LIFT ASSEMBLY PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

#9040 FUEL TANK SWEEPER

M-1115S Series Fuel Pump

JARVIS. Model Hydraulic Cutter EQUIPMENT... TABLE OF

KJ4000LW Operating Instructions & Parts Manual NSN

WALKIE HIGH LIFT HYDRAULIC SYSTEM

MIDRISE MODEL SM60F_1 // SM60F_A 6,500 LB. CAPACITY

Troubleshooting the Transmission Hydraulic System

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Installation and Operating Manual

Rev: Flow Max 115V AC Fluid Pump

12AT/50AT Series. Spin-On Filters. Global Filtration Technology

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.

Monarch D.C. Hydraulic Power Systems. Comprehensive information may be found on the page referenced below each selection category.

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

NECO Pumping Systems

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Starting up hydraulic systems

END SUCTION CENTRIFUGAL PUMPS

THE TRACTOR AND/OR LOADER (IF EQUIPPED)

JARVIS. Model 30CL-1 and 30CL-3 Hock Cutter and Dehorner

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

Owners Manual: - Pumps

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar

Stainless Steel Rotary Drum Pump

WARCO CHEMAG SERIES GH FILTERS

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

The TR-Series are large volume,

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

High Lift Transmission Jack

Model Repair Parts Sheet SPECIFICATIONS. Stake threads lightly after assembly. Note: Pump base is not available as a service item.

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Hydraulic and Commissioning Mannual Module 2A

Form No , 9 5, 6. Parts List for: X1A1 AIR DRIVEN WITH REMOTE CONTROL HYDRAULIC PUMP. Max. Capacity: 10,000 PSI

6 Litre Oil-Less Air Compressor

MODEL B ELECTRIC HYDRAULIC PUMP TOP VIEW

Installation & Operator s Manual

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

HYDRAULIC STEERING MANIFOLD HM260 TABLE OF CONTENTS. 1. GENERAL INFORMATION... p TECHNICAL SPECIFICATIONS... p. 01

Hydraulic Hand Pallet Trucks

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

SERVICE MANUAL. PVR15-Manifold Series Pump. J Design Series INSTALLATION. Ordering Code PVR15 - _ RM - _ - - J

JARVIS. Model 50G Hydraulic Dehorner

Service Manual for Hydraulic Vane Pumps Flange Mounted

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Arctic Equipment Manufacturing Corporation M3551 Hydraulic Power Unit. Table of Contents

MODEL MC1500 Installation and Operation Manual Important:

Technical Information for PVX Series Pumps

Pressurized Bead Filters

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

VACUUM PUMP SERIES VP & VPC SINGLE - DUAL STAGE VACUUM PUMPS OPERATION MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

Cleaning Systems Inc. 2 P Rev:03

Transcription:

Low Profile J Series Power Unit with Vane Pump

READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. WARNING: THIS INSTRUCTION MANUAL IS INTENDED FOR USE BY QUALIFIED INDIVIDUALS WITH A WORKING KNOWLEDGE OF HYDRAULIC AND ELECTRICAL PRINCIPLES. PROFESSIONAL INSTALLATION IS RECOMMENDED. Description The hydraulic power units detailed herein are designed to operate on 3 phase, AC electric power. Each power unit consists of a pressure balanced vane pump, powder coated reservoir, Premium Efficiency three phase electric motor, anti-vibration bars, spin-on type return filter, and a factory set System Safety Relief valve. Each unit is equipped with a Pressure port at the manifold and a Tank Return port at the return line filter head. The units are to be connected to remote mounted valving. The power units can be coupled via suitable hydraulic lines to a wide variety of directional control valves and hydraulically operated devices. Proper circuit design must be considered when selecting directional control valves and load control valves to ensure safe and predictable movement of all hydraulic actuators and connected devices. We recommend using Open Center or Tandem Center directional control valves. If the hydraulic unit is to be connected to Closed Center or Float Center valves, the circuit must include an unloading valve to avoid having the system running over the relief valve when the closed center directional control valves are not shifted. Specifications All units have: Totally enclosed fan cooled Premium Efficiency electric motor, rated for 60 Hz and 50 Hz voltages (see motor nameplate for full details of ratings) Anti-vibration mounts between the electric motor and the reservoir top plate Pressure balanced vane pump Powder coated reservoir plumbed for vertical only mounting Adjustable Safety Relief Valve preset at the factory Aluminum manifold with SAE #12 Pressure port and cartridge style air bleed valve Suction strainer at pump inlet SAE #16 ported return line filter with spin-on type, 10 micron canister and visual by-pass indicator Bayonette style filler / breather assembly with strainer basket Sight / level / temperature gauge Liquid filled pressure gauge with isolator ¾ NPT drain port on lower front of reservoir 1 P a g e Unpacking Check package for any external signs of damage that may have occurred during transit then unpack the unit and check for physical signs of damage. If components are missing or there is any noticeable damage, please contact the office where the item was purchased.

Figure 1 38VP30 Figure 4 38VP31 Figure 2 38VP30 Dimensions Figure 5 38VP31 Dimensions Figure 3 38VP30 Hydraulic schematic Figure 6 38VP31 Hydraulic schematic 2 P a g e

Assembly All the power units are packaged fully assembled. Customer is responsible to fill the reservoir with proper level of a quality hydraulic fluid suitable for use in the intended environment. Customer must also supply and install all directional control valves to be mounted remote from the hydraulic power unit. Figure 7 38VP33 Installation of Hydraulic Power Unit 1. Select a good location to mount the hydraulic power unit. It should be in a clean, level, dry area with adequate ventilation and preferably near the electric power source. NOTE: Although the units have totally enclosed fan cooled motors, they still need free air circulation around the motor and reservoir to displace heat. CAUTION Avoid dusty conditions that could clog the reservoir breather. Figure 8 38VP33 Dimensions 2. This hydraulic power unit is designed for vertical mounting with the reservoir feet down and the reservoir breather on the top. Choose a flat, level mounting surface to bolt the reservoir feet to. See unit dimensions for reservoir base bolt pattern. The hydraulic unit is plumbed For vertical mounting as noted above. Mounting the unit in an inclined plane or any other position will greatly reduce the available usable oil in the reservoir. This can cause the hydraulic oil to foam resulting in erratic movement of hydraulic components, and pump failure. CAUTION Figure 9 38VP33 Hydraulic schematic To minimize contamination problems, do not remove plastic shipping plugs from hydraulic unit until you are ready to install hoses and fittings. 3 P a g e

3. HYDRAULIC INSTALLATION Make sure that the work area and the hydraulic components are clean and free from dirt, debris,lint, etc. 4. Install properly sized tandem center or open center directional control valves and any required load control valves. 5. Connect your hoses and fittings to the hydraulic valves, actuator (hydraulic cylinder, hydraulic motor, or other devise) and when ready to connect the hydraulic power unit ports, remove and discard plastic shipping plugs from the P port of the aluminum manifold and from the T port of the return filter head. CAUTION! Do not use Teflon tape. This unit is equipped with SAE O-ring type ports. Do not over-tighten fittings. 6. Remove the reservoir breather and fill the hydraulic unit reservoir with a good quality hydraulic fluid. It is recommended that hydraulic fluids have a viscosity between 150 SUS and 225 SUS at 100 degrees F and the maximum operating temperature should not exceed 140 deg. F. The reservoir should be filled to the upper (blue) line of the sight / level / temperature gauge but not above. 7. Use of a filter cart to add fluid to the reservoir is highly recommended. Do not pour hydraulic fluid directly from a pail or drum as this can result in debris entering the reservoir. 8. Re-install the breather on the reservoir. Electrical Wiring 1. When wiring the motor, follow all local electrical and safety codes as well as the National electrical codes in your jurisdiction (i.e. NEC, ESA, etc) and all Occupational Safety and Health Act (OSHA) requirements. 2. Make certain that the wire size is adequate for the horsepower requirements (see chart on page 6). NOTE: Voltage drop increases with the length of power cord. Larger wire diameter may be required. 3. Motor nameplate voltage level must be available at the motor when it is operating under load. Avoid voltage drop by using adequate wire size. 4. DOUBLE CHECK ROTATION! Motor rotation is clockwise facing fan end of motor (which means the motor is wired to turn counter clockwise when facing the shaft of the motor). 5. On start-up, ensure an open flow path for the hydraulic circuit and jog the motor to ensure correct rotation and to prime the pump to ensure adequate lubrication. After the correct motor rotation is confirmed and the fluid is moving freely, motor may be operated at full speed. CAUTION! Never run the system without adequate levels of hydraulic fluid in the reservoir. New installations will require additional fluid to fill the lines, cylinders etc. so check the reservoir fluid levels frequently during initial operation to ensure the fluid level does not go below the minimum level on the sight gauge. 6. Keep all electrical lines as short as practical. 7. Never exceed the maximum operating pressure. 8. Do not over-tighten fittings, bolts, etc., as this can damage the units. 9. Provide adequate cooling for the hydraulic oil so as not to allow oil and/or component damage due to excessive temperatures. Excessively high operating temperatures will be hazardous and may cause property damage and/or personal injury. 4 P a g e

WARNING REPLACE OR REPAIR DAMAGED OR WORN POWER CORDS IMMEDIATELY. WARNING DO NOT OPERATE UNITS WITHOUT PROPER GROUNDING. WARNING DO NOT RUN THE HYDRAULIC UNIT DRY AS THIS WILL CAUSE SEVERE PUMP DAMAGE. PRIOR TO OPERATION: 1. Double check all hydraulic and electric connections. 2. Confirm that reservoir is filled with hydraulic fluid. 3. Put all equipment guards in place 4. Clear all persons from work area 5. Check for loose tools, equipment, or anything that might interfere with operation of equipment. OPERATION 1. Start Up When initially starting unit up, be sure to jog the unit (intermittently run unit) several times. This will prime the pump and fill the hydraulic lines. CAUTION Check motor fan rotation again at this time to avoid damaging pump or pump shaft seal. WARNING IF MOTOR IS TURNING IN THE WRONG ROTATION, SHUT OFF ELECTRICAL POWER BEFORE ATTEMPTING TO CHECK OUT MOTOR WIRING. Maintenance 1. Keep the reservoir filled to the proper level with hydraulic fluid. Use a good quality hydraulic fluid that is suitable for use in the intended environment. 2. Check the reservoir fluid level and return line filter condition on a regular basis and use new, filtered hydraulic fluid when adding fluid. Most pump/fluid motor failures, valve malfunctions, and short unit life can be traced directly or indirectly to dirt or other foreign materials (water, debris, lint, etc.) entering or already in the hydraulic system. 3. Make a frequent inspection of hydraulic fluid and change if contaminated. 4. Check the return line filter indicator on a regular basis and replace the spin-on canister before the indictor reaches the red area. 5. Regularly inspect hydraulic hoses and fittings for wear or leakage. 6. Keep the unit and surrounding area clear of dirt and foreign materials. 7. Keep electrical connections clean. 5 P a g e

Troubleshooting Chart SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION Motor won t start 1. Loose connection 2. Circuit breaker tripped 3. Voltage drop 4. Seized pump 1. Check wiring 2. Reset circuit breaker 3. Use heavier gauge wire 4. Replace pump Will not pump oil (Motor runs but cylinder does not move, or moves slowly) Pump motor unit is noisy Unit does not develop full pressure 1. No oil in reservoir 2. Motor rotation incorrect 3. Oil level low 4. Relief valve is held open 5. Suction strainer is clogged 6. Hydraulic cylinder (or motor etc) seals are cut or worn out. 7. Reservoir breather is dirty or clogged. 1. Low oil level 2. Air in system 3. Suction strainer or inlet filter is clogged 1. System relief valve set too low, or leaking 2. Pump worn out 3. Air in system 4. Oil temperature is too high HYDRAULIC POWER UNIT PERFORMANCE 1. Check oil level, refill 2. Rewire 3. Add oil as needed 4. Flush relief valve 5. Clean suction strainer 6. Replace or repair cylinder (or motor etc) 7. Clean reservoir breather and reinstall 1. Add oil as needed 2. Bleed air from highest fitting in system by loosening fitting very slightly and operating unit until bubbling of air stops, then tighten 3. Clean suction strainer or inlet filter 1. Check system relief valve for proper setting 2. Replace the pump 3. Bleed air from systems 4. Let oil cool well below 140 F MODEL Reservoir Capacity HP Nominal Flow Max. Pressure Voltage Phase Hz Full Load Amps 38VP30 20GAL. 7.5 7.5 GPM 1500 208-230/460 VAC 3 60/50 17.7-8.86/7.08 38VP31 20GAL. 10 10.0 GPM 2000 208-230/460 VAC 3 60/50 23.9-12.0/9.55 38VP33 30GAL. 10 10.5 GPM 1500 208-230/460 VAC 3 60/50 23.9-12.0/9.55 6 P a g e

7 P a g e

NO. DESCRIPTION 38VP30 38VP31 38VP33 QTY 1.1 Reservoir 51020641121 51020641121 51020641122 1 1.2 Nut, Multi-thread U, 5/16UNC-18 500205207870 500205207870 500205207870 12 FOR 38VP30 & 38VP31 14 FOR 38VP33 1.3 Plug, Steel, 3/4" NPT 500205901075 500205901075 500205901075 1 1.4 Gauge, 5" Sight-Temperature 500203701436 500203701436 500203701436 1 2.1 Nipple, 1 NPT X 16 Long 51020511161 51020511161 51020511161 1 2.2 Fitting,street elbow,1 NPT,black pipe 51020330448 51020330448 51020330448 1 2.3 Suction strainer,1 NPT,15gpm 51020940096 51020940096 51020940096 1 3.1 Top plate 51020581123 51020581123 51020581124 1 3.2 Gasket, 0.125 thickness,10feet long 51020361157 51020361157 51020361157 1 3.3 Screw,Hex washer hd,5/16unc X 1 500206907869 500206907869 500206907869 12 FOR 38VP30 & 38VP31 14 FOR 38VP33 3.4 Tube,return,3/4 NPT X 11-1/2 lg 51020830693 51020830693 51020830693 1 3.5 Tube,return,1 NPT X 11-1/2 lg 51020831155 51020831155 51020831155 1 3.6 1 suction flange 51020331319 51020331319 51020331319 1 3.7 Screw,washer style h.h., 5/16-18x3/4 lg 51020691074 51020691074 51020691074 4 3.8 Anti-Vibration bar,,bolt down, 213/215 51020940095 51020940095 51020940095 2 3.9 Screw,SHCS,3/8-16 X 1 plated 500206907592 500206907592 500206907592 4 3.10 Spring washer, for SHCS 3/8-16 51020861166 51020861166 51020861166 4 4.1 Vane pump,sae A,7.5gpm@1800rpm 51020630192 51020630192 51020630193 1 4.2 Manifold,P&T pts c/w two C10-2 cavities 51020491119 51020491119 51020491119 1 4.3 Relief,10,2w,P.O. 5205100833 5205100833 5205100833 1 4.4 Velocity fuse / Air Bleed valve, C-10-2 51020850851 51020850851 51020850851 1 4.5 Valve,shut-off,1/4 NPTF 500208500570 500208500570 500208500570 1 4.6 Gauge 0~2000 l.f. ¼ NPT,back mount 51020370015 51020370016 51020370015 1 4.7 Screw,SHCS,3/8-16X1-3/4lg 51020690877 51020690877 51020690877 2 4.8 Washer,internal tooth lock,3/8 500208607839 500208607839 500208607839 2 4.9 Washer,13/32 IDX3/4 OD X.091 thick 500208601970 500208601970 500208601970 2 4.10 Adapter,#12 SAEM union 51020330022 51020330022 51020330022 1 4.11 Fitting adapter,#12jic-#12saem 51020330335 51020330335 51020330335 1 4.12 Hose ass y,#12jicf to #12 JICF 51020441175 51020441175 51020441167 1 4.13 Adapter,#12 JIC male-#12npt male 51020330263 51020330263 51020330263 1 4.14 #6 SAE plug 51020330028 51020330028 51020330028 1 4.15 #12 SAE plug 51020330031 51020330031 51020330031 1 5.1 Adapter,P/M,254/256TC-SAE A 51020000016 51020000016 51020000016 1 5.2 Screw,hex head,1/2-13 x 1-1/2 lg 500206907871 500206907871 500206907871 4 5.3 Washer,1/2 internal tooth lock 500208607840 500208607840 500208607840 4 5.4 Washer,1/2 SAE flat plated 500208601969 500208601969 500208601969 4 6.1 Coupling,3/4 dia. X 3/16 key 51020220013 51020220013 51020220013 1 6.2 Coupling,1-3/8 dia. X 5/16 key 51020220017 51020220017 51020220017 1 6.3 Insert, nitrile 51020750011 51020750011 51020750011 1 7.1 Motor 510205004551620 510205005051620 510205005051620 1 7.2 Screw,hx. Hd. Cap. 3/8-16x1-1/4 500206907842 500206907842 500206907842 4 7.3 Washer, internal tooth lock,3/8 500208607839 500208607839 500208607839 4 7.4 Washer,13/32 IDx ¾ ODX.091 500208601970 500208601970 500208601970 4 8.1 Filter head with 15PSI by-pass 51020320130 51020320130 51020320130 1 8.2 Gauge,pressure,color indicator 500203701899 500203701899 500203701899 1 8.3 Filter element,spin on,0~34gpm 51020320126 51020320126 51020320126 1 8.4 Nipple,1 NPT X 12 lg 51020511156 51020511156 51020511156 1 8.5 90 adapter #16 ORBMX1"NPTF 51020331322 51020331322 51020331322 1 9.1 Filter Breather Cap Assembly 500203201425 500203201425 500203201425 1 9.2 Screw, 10-32UNC X3/4" 51020690744 51020690744 51020690744 6 8 P a g e