LIEBERT APM 3-PHASE UPS: 15-90KVA/KW, 60HZ, VAC, SINGLE & DUAL INPUT - SITE PLANNING DATA

SITE PLANNING DATA LIEBERT EXM 3-PHASE UPS: KVA/KW, 60HZ, VAC, SINGLE INPUT

Sheet No. Component /Detail Description 1 Draw ing Guide Galaxy VM 225 kva 1 Module UPS w ith Modular Battery Cabinet Draw ing Guide 2-3 Solution

Galaxy VM 160kVA 1+1 Module UPS with Modular Battery Cabinets Solution Drawing Guide Sheet No. Component /Detail Description 1 Draw ing Guide Galaxy

POWER kva

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

EATON 9315 UPS 200 TO 300 KVA Specifications

POWER kva

Galaxy VM 160kVA 1 Module UPS with Modular Battery Cabinets Solution Drawing Guide Sheet No. Component /Detail Description 1 Draw ing Guide Galaxy VM

Galaxy VX. 480 V UPS System Technical Specifications 07/

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Galaxy VX. 380 V, 400 V, 415, and 440 V UPS System Technical Specifications 12/

Features and Benefits

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

Single and Parallel Installation. MGE Galaxy kva 208/220 V

MGE TM Galaxy TM 7000 GFC

TECHNICAL DATA SHEET KVA UPS Systemss

Galaxy Installation 08/

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

EFFEKTA Power Supplies

TLE Series UPS 160/200/225/250 kw with eboost Technology

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Single and Parallel Installation

Pretest Module 24 Three-phase Service Entrance

Product Overview. Enclosure for batteries N PE/G. Battery (customer-provided - shown for reference only) Battery output terminals

Single and Parallel Installation

TLE Series UPS 400/500 kw With eboost Technology

Calculation of the Cross-sectional Areas of Circuit Live Conductors

PowerValue 11/31 T kva

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

DISCONTINUED PRODUCT POWER PROTECTION. Series 600 UPS. Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz. Installation Manual

MGE Galaxy 5500 Marine

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Technical Specifications

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

MGE Galaxy 5000 MGE Galaxy 5500 MGE Galaxy 6000 MGE Galaxy PW

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

Technical Data Sheets

Phase Modular Finally the benefits of Modular ups are for all

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Custom Product Brochure. Custom Design Engineering Team July 1, 2014

Smart-UPS VT kva 208/220 V Single and Parallel Installation. With Batteries 11/2016.

MGE TM Galaxy TM 7000

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

ERIFLEX FLEXIBAR PLAIN COPPER

Illuminator Series CR NEMA 3R

Emergency lighting units EM converterled

Contractors Guide Central Inverter System Installation

TLE Series UPS 750/1000 kw With eboost Technology

Distribution Blocks & Bus-bar Solutions

SS SyStem SyStemy free UPS tter ba UPS

Galaxy : kva 380/400/415 V 3: kva 220/230/240 V. Technical Specifications 04/

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

GUIDE SPECIFICATIONS 15-45kVA and 15-90kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

IS46/PS33 Current Power Supply System

Technical Data Sheets

Electrical Installation

E-15 Uninterruptible Power Systems (UPS)

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Data Sheets

AIS 5000 UPS kva 480 V. Installation Manual

Symmetra PX. 250/500 kw 400/480 V Single and Parallel Installation 07/

Aurora Single Phase Emergency Lighting Inverters

Galaxy VX Battery Breaker Trip Board (GVXBBTB) and Battery Breaker Capacitor Board (GVXBBCB)

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

Liebert ITA2 UPS Compact, Efficient & Robust UPS for Critical Applications 5-20kW/kVA GUIDE SPECIFICATIONS

Galaxy VM. Battery Breaker Box Installation 09/

IEEE Guide for the Design of Low Voltage AC and DC Auxiliary Systems for Substations

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

POWERTRONIX QUASAR 5-40 KVA

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Technical Data Sheets

Uninterruptible Power Supplies

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

Emergency lighting units EM converterled

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

High Bay Luminaire Series

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

AC Power For Business-Critical Continuity. Liebert NXL. Installation Manual kVA, 60Hz, Three-Phase, Single-Module

Enterprise Power Protection

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Specifications

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

HBDBM High Bay Series

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Installation. Symmetra MW II kw 480 V. UPS Summary Normal Normal

Transcription:

Sheet No. Component /Detail Description 1 Draw ing Guide MGE Galaxy 7000 200kVA 2MOD (N+1) 400V Integrated Parallel Module UPS Draw ing guide. 2-4 Solution MGE Galaxy 7000 200kVA 2MOD (N+1) 400V Integrated Parallel Module. 5-6 UPS MGE Galaxy 7000 200kVA 400V. 7 Battery MGE Galaxy 7000 200kVA Battery Cabinet. 8-9 System One Line Diagram MGE Galaxy 7000 200kVA 2MOD (N+1) 400V Integrated Parallel Module System One Line Diagram. 10 System Wiring Diagram MGE Galaxy 7000 200kVA 2MOD (N+1) 400V Integrated Parallel Module System Wiring Diagram.

Rating SKU Number UPS COG Details in mm X-Distance Y-Distance Z-Distance 200kVA G7TUPS200 706 680 350 Floor Loading Data Rating Dimensions Weight Floor Loading H x W x D in kg kg / m2 200kVA UPS 1900x1412x855 840 696 1012 Wide Battery Cabinet 1900x1012x855 1419 1640

Galaxy 7000 UPS 200kVA 2Module (N+1) Site Planning Data Parallel UPSs. Input and output Voltage : 400V AC UPS UPS AC Input BATTERY UPS AC Output System UPS Mechanical Data Rating kva kw Input (V) Nominal Current (A) Maximum Current(A) see note 2 Recommended Over current Protection Device Ratings Individual UPS (A) Nominal Minimum / Maximum VDC Battery kw Battery Current Output (A) (V) (in UPS Cabinet) Nominal Current (A) Individual UPS Recommended Over current Protection Device Ratings Individual UPS (A) System Output kva Nominal System Output Current (A) Typical Dimensions H x W x D (mm) see note 12 200 180 400 281 294 400 528 / 576 192.5 458 400 288 400 200 288 1900x1412x855 840 696 6.8 13.5 1. Input current based on full rated output load. 2. Maximum (Max.) current is for duration of battery recharge. 3. Input and bypass cables must be run in separate conduits from output cables. Not more than three conductors in raceway assumed; ambient temperature of 30 C assumed. 4. If initial load is less than UPS' rated output, it is recommended that AC input, battery, and AC output wiring and over current protection be sized to UPS full load rating to accommodate possible future expansion. 5. Nominal battery voltage is shown at 2.0 volts/cell. 6. DC cables should be sized for a total maximum of less than 1% of CB rating. 7. Wiring requirements: - AC Input/Output: 3Ø, 3 or 4 wire + ground, depending on UPS configuration. See Installation Manual and submittal drawings for specific instructions. - DC Input: 2 wire (positive and negative) + ground 8. All wiring to be in accordance with all applicable national and/or local electrical codes. 9. Minimum access clearance per UPS drawings. 10. Top or bottom cable entry through removable access plates. Punch plates to suit conduit size, then replace. 11. Control wiring and power wiring must be run in separate conduit. 12. Weights and dimensions shown do not include battery cabinet(s), distribution cabinet(s), or other options. 13. Backup emergency generator must be properly sized for UPS application and equipped with an isochronous governor for frequency regulation, and a UPS-compatible voltage regulator for voltage stability. 14. If site configuration requires an external maintenance bypass, phase parity between UPS input and UPS bypass must be ensured. Consult Schneider Electric applications engineer. 15. The UPS must be installed in a room with restricted access, in compliance with standard IEC 60364-4-42. 16.Cable installation to comply with EN60364-5-52, max ambient 30 deg C, cable sizes shown refer to 600V rated,90 degree C multicore copper conductors with thermosetting insulation 17. Input I THD < 5% at Full Load 18. Output V THD < 2% Linear Load, <3% Non Linear Load 19. Input power-factor is > 0.99 for > 50% loading. Average weight Kg see Note 12 Floor Loading kg / m2 Heat Losses in kw Batteies fully charged Heat Losses in kw Batteies charging Efficiency Details System 25% load load 50% 75% load 100% load 200 kva 400 V 90 93 93.2 93