SecureUPS On-Line 120V AC Output, 1300VA

Similar documents
Smart UPS On Line 120/208 V

Smart-UPS On-Line 230 V

Unity output power factor single-phase double-conversion, online UPS with advanced management features

Smart UPS On Line 120/208 V

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

Smart-UPS On-Line Lithium-ion UPS 230V

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Features and Benefits

Model ES VA to VA SINGLE PHASE UNINTERRUPTIBLE POWER SYSTEM

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

Smart-UPS with APC SmartConnect Maintain business certainty with intelligent network power protection

TECHNICAL DATA SHEET KVA UPS Systemss

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Series 120/120VAC Universal Tower/Rack Mount

Uninterruptible Power Systems

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

On-line, Single Phase, Double Conversion UPS

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation and Operation Manual Back-UPS BR800/1100CI-IN

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and Operation Manual Back-UPS BR1000-CH

Back-UPS CS Back-UPS CS 350

Smart-UPS: legendary uninterruptible power. Intelligent, reliable protection for servers and networks

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

3 Uninterruptible Power Systems

MKN-DSP SERIES - THREE PHASE

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Symmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Features and Benefits

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Technical data sheets

Smart-UPS: legendary uninterruptible power. Intelligent, reliable protection for servers and networks

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Installation and Operation Back-UPS BX550CI-CN

Technical data sheets

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

Onfiniti. 1 Phase UPS

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

S2000 PRODUCT RANGE. Ultra compact

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Technical Data Sheets

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Liebert GXT4. Intelligent, Reliable UPS Solution 700VA - 3kVA

3 Uninterruptible Power Systems

Maintain business certainty with intelligent and efficient network power protection for your network closets and server rooms.

Technical Data Sheets

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Multilink Transportation Power Solutions

PowerValue 11/31 T kva

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower 100/120/230 Vac. 500 VA Tower 100 Vac

Technical Data Sheets

Aurora Single Phase Emergency Lighting Inverters

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Up to 98% efficient under full load Similar runtimes to the previous 3u model

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

D Series: UPS UPTO - 300KVA - Three / Three Phase

Protection and conditioning against all forms of power anomalies.

Technical Data Sheets

Installation and Operation Smart-UPS SUA500PDR

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

User Manual Easy UPS On-Line SRVS Series Rack-Mount 1000VA, 2000VA, 3000VA

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

MGE Galaxy 5500 Marine

Technical Data Sheets

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Enterprise Power Protection

1. Important Safety Warning

UPS SYSTEMS PDUs SURGE PROTECTORS POWER INVERTERS DATACENTER UPS. Product Catalog

Eaton 9PXM. 4-20kVA Split-Phase Rack-Tower UPS Guide Specification

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

AT EVO SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Schneider Electric Conext SW

Transcription:

SecureUPS On-Line 120V AC Output, 1300VA Trusted Power Protection Solution for Intelligent Transportation Systems (ITS) Challenges Intelligent transportation systems (ITS) are using innovative traffic management technology such as adaptive signal controls, emergency vehicle preemption and incident monitoring to help citizens use roadways in a safe and efficient manner. As more intelligent devices are installed in roadside cabinets, the prevention of equipment failures due to power events becomes more critical. Solution Designed to operate in harsh environments, APC SecureUPS provides high-density, double-conversion online power protection and advanced management for ITS. When used with external batteries, the model ensure back-up time during power outages. The SecureUPS is a perfect solution to protect your systems from power outages and prevent unnecessary maintenance calls due to power fluctuations. Benefits 1 Improve Intersection Safety While Reducing Operating Costs Clean power with double-conversion on-line technology: Lowers maintenance costs by reducing service calls to reset signal operation Reduces risk due to dark/flashing intersections by improving signal uptime Extends battery life by lowering cycle count Extends battery life by handling many power quality issues electronically 2 Remotely manage your UPS Fleet with Certainty Configure, receive notifications, review event logs, run diagnostics test & check battery runtime status Manage the entire system with detailed battery information and early fault warnings Ecostruxure IT TM integration: collect & distribute critical alerts with a unified view of physical infrastructure environments from anywhere on the network What do customers say about SecureUPS? www.apc.com/secure-ups 3 Maintain ITS Network Security Imbedded Network Management Card 2 (NMC2) allows for secure remote monitoring & control of a UPS via web browser, CLI, SNMP (v1/v2c/v3), Modbus TCP and BACnet/IP Adopts the latest network communication protocols for improved security 4 Eliminate Maintenance Headaches Field replaceable fan/filter for easy replacement Quick troubleshoot with user-friendly LCD screen 24/7 support from Schneider Electric s established service & support team 5 Outperform Roadside Environments Conformally coated for humidity & pollution tolerance Designed for 37 C to +74 C (-40 F to 165 F) operating temperatures with integrated temperature compensated charging system The 1300VA power management unit takes everything that makes APC great in the server room and puts it on street in intelligent transportation systems. The power protection and battery backup features are a great fit for an intersection, while the remote monitoring capabilities and versatility allow for easy deployment in any traffic cabinet. -Eric from City of Sevierville, Tennessee

SecureUPS On-Line 120V AC Output, 1300VA Product Overview 6 3 5 7 9 11 12 13 8 10 1 2 4 18 18 16 20 19 17 15 14 1 Easily Replaceable Filter 11 Battery Communication Connector 2 3 4 5 Easily Replaceable Fan Assembly Serial port to communicate with the SecureUPS External Battery Circuit Breaker to connects/disconnect battery power USB Port 12 13 14 15 External bypass box interface (RS485 and +24 VDC power) Input AC Circuit Breaker to connects/disconnects AC power AC Input Connector AC Output Connector 6 7 Universal I/O Port to connect optional environmental monitoring accessories Reset Button to restart the Network Management Interface 16 17 18 Relay Input Connector Battery Test Points Relay Output Connector 8 9 Ethernet Port for network communication Status LEDs 19 Battery Temperature Sensor Connector (Sensor cable and mating connector are supplied with the battery harness kit) 10 LCD for real-time status updates and UPS control 20 High Current DC Output Connector (Cables are not provided along with the UPS.) LCD Display Features LCD display screen Accurately provides real-time status updates in your choice of basic or advanced menus UPS status (scrolling) Output voltage Input voltage Output frequency Runtime Load Battery health Control UPS and outlet group settings Bypass control Configuration Output voltage, frequency Language, brightness, contrast Alarm volume IP address Test and diagnostics Initiate battery and runtime calibration tests About UPS serial number, battery part number Battery install and suggested replacement dates

SecureUPS On-Line 120V AC Output, 1300VA Main applications Traffic Signals Ramp Metering Roadside Monitoring Systems Dynamic Message Signs Certainty in Public Safety Public Transportation Field Controls Be prepared for any utility power Tolling challenge Systems thrown your way with Tunnel best-in-class Control Systems UPS technology Rail Crossings Never question Signals the status of your UPS fleet again with highly secure remote management offerings Built with maximum serviceability to help relieve headaches and time spent on maintenance and troubleshooting Accessories Battery Harness Kit (required) Connect the 48V battery string to the product to enable the use of multiple battery strings. XHXXS7A4F - SBS75 Cabinet Accessory 4 ft XHXXS7A8F - SBS75 Cabinet Accessory 8 ft Extended Temperature Batteries Long backup times available with up to eight 100 Ah lead-acid batteries. Extend temperature with batteries best suited for harsh environments. XB102XX1XS - Battery 100Ah 12Vdc XB050XX1XS - Battery 50Ah 12Vdc Service Bypass Unit with Generator Inputs Removes the UPS for service without disrupting the operation of the traffic signal while allowing for generator input power Part number:xs30allxxr2g Battery Heater Mat Allows battery use in extreme temperatures 2 sizes available: 256 and 365 sq. in. XM050DXXXA - Battery Heater Mat 256 Sq In. 120Vac XM102DXXXA - Battery Heater Mat 365 Sq In. 120Vac Environmental Monitoring Accessories Optional accessories to increase environmental control through sensors. AP9335TH - Temperature/humidity sensor AP9810 - Relay input/output connector - supports two input contacts and one output relay Service Bypass Unit without Generator Inputs Removes the UPS for service without disrupting the operation of the traffic signal Part number:xs30allxxr2 Trusted power protection for Intelligent Transportation Systems

Technical Specifications Secure UPS Product SKU XU1K3LLXXRCC Output Output Topology Nominal Output Voltage Output Power Rating Double Conversion On-Line 1300 W, 1300 VA, with no derating over full temperature range Output Voltage Regulation (static) ± 1% Output Frequency (nominal) Output Waveform 50/60 Hz ± 3 Hz True Sinewave Input Nominal Input Voltage Input Voltage Range Input Frequency Input Connection 83 to 157 Vac 40 to 70 Hz Single phase, 3 wire (Line, Neutral and Ground) Communication and Management Interface Ports Control Panel and Audible Alarms Ethernet via Embedded Network Management Card (NMC) & USB High-resolution graphical LCD display; alarm on battery, distinctive low battery alarm and configurable delays Environment Temperature - Operation -40 to 74 C (-40 to 165 F) Temperature - Storage (without batteries) -40 to 85 C (-40 to 185 F) Maximum Elevation - Operating Maximum Elevation - Storage Humidity 0 to 3,000 m (0 to10,000 ft) 0 to 15,000 m (0 to 50,000 ft) 0% to 95% relative humidity, non-condensing Physical Unit Weight without Packaging Unit Weight with Packaging Unit Dimensions without Packaging Unit Dimensions with Packaging 12 kg (26.5 lb) 13.5 kg (29.8 lb) 434 mm x 260 mm x 88 mm (17.1 in x 10.3 in x 3.5 in) 535 mm x 370 mm x 186 mm (21.1 in x 14.6 in x 7.3 in) Conformance Warranty 3-year factory warranty with optional extended warranty External Batteries SKU XB050XX1XS XB102XX1XS Rating 50 Ah, 12 Vdc 100 Ah, 12 Vdc Battery Type Maintenance-free sealed lead-acid battery with suspended electrolyte; leak proof Typical Backup Time at Varying Load Conditions Please refer to www.apc.com for runtime charts Battery Harness Kit SKU XHXXS7A4F XHXXS7A8F Descriptions SBS75 cabinet accessory 4 ft SBS75 cabinet accessory 8 ft

Technical Specifications Service Bypass Unit Product SKU XS30ALLXXR2G XS30ALLXXR2 Output Nominal Output Voltage # of Outlets 1 Outlets Connection type Overload protection 4 pole PP45 power pole connector No Input Nominal Input Voltage Current Rating Input Frequency Recommended Input circuit Breaker 30A Max 50 to 60 Hz 30A,Dual pole branch rated Generator Input N/A Environment Temperature - Operation -40 to 74 C (-40 to 165 F) Temperature - Storage (without batteries) -40 to 85 C (-40 to 185 F) Maximum Elevation - Operating Maximum Elevation - Storage Humidity Protection Class 0 to 3,000 m (0 to10,000 ft) 0 to 15,000 m (0 to 50,000 ft) 0% to 95% relative humidity IP20 Physical Unit Weight without Packaging 2.2 kg (4.9 lb) 1.25 kg (2.8 lb) Unit Weight with Packaging 5.7 kg (12.6 lb) 4.5 kg (9.9 lb) Unit Dimensions without Packaging Unit Dimensions with Packaging 432 mm x 100 mm x 88 mm (17 in x 3.93 in x 3.5 in) 535 mm x 370 mm x 186 mm (21.1 in x 14.6 in x 7.3 in) 280 mm x 72 mm x 88 mm (11 in x 2.8 in x 3.5 in) 460 mm x 295 mm x 190 mm (18.1 in x 11.6 in x 5.9 in) Conformance Safety CALTRANS Warranty UL-1778 (CSA 107.3 for Canada) Caltrans Specification (TEES) March 12, 2009 version 3-year factory warranty

www.apc.com/secureups 132 Fairgrounds Rd West Kingston, RI 02892 Phone: + 01 (401) 789-5735 www.schneider-electric.com 2019 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.