Floodlight Range Installation Guide

Similar documents
Zone 1 Linear Range - Installation Guide

Clarius EP PLUS LED FLOODLIGHT Installation Guide

Operating Instructions

ILED Aquarius Illuminated Windsock. User Manual

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Floodlight LED Series 6525

Floodlight LED Series 6525

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Operating Instructions

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

OPERATING INSTRUCTIONS

ILED Dorado. User Manual

Floodlight LED Series 6125

Terminal Boxes in Stainless Steel SLS**.T

Operating Instructions

INSTRUCTION MANUAL (ATEX / IECEx)

Ex m Solenoid Operator Type 0519

INSTRUCTION MANUAL (ATEX / IECEx)

OPERATION AND MAINTENANCE INSTRUCTIONS

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

BMRX Series ROTARY LEVEL CONTROL

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Compact Sheet-steel Emergency Light Fitting Series 6118/1

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

IQL Helios Area-/Streetlight. User Manual

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

CCAI, CCAIF, CCAIF..H

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

Floodlight Series 6121

Emergency Light Fitting for Fluorescent Lamps Series 6009

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Easy and safe installation

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Compact Sheet-Steel Light Fittings Series 6114/1

VALIADIS S.A. HELLENIC MOTORS

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Position Switches Series 8074/2

TECHNICAL BULLETIN. Sandvik MB670 Bolter Miners

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Type Electronic Limit Switch

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

EX-REPAIR AND MAINTENANCE RECEPTACLES

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Flameproof Level Sensor (Flameproof F/S FP)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6402/2

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Solenoid Operator 0516 / 1216

HTSB system System overview

Emergency Luminaire with LED Series EXLUX 6409/1

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Mechanical features. Spring-loaded elastic terminals: resist vibrations

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

Linear luminaire with LED Series EXLUX 6002

HAZ AREA LIGHTING. Product Brochure. Design to Manufacture FOR HAZARDOUS AREAS. Engineering Solutions. An A-Belco Group Company

Position Switches Series 8070/2

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS

Position Switches Series 8060/2

Product manual cable glands type IR and IB. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Linear fittings EVDL LED fitting - zones 21, & 22

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

Instruction Manual. Ex-Time 40 / 50

Pendant Light Fitting IEC

Technical Data. Dimensions

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Leading the way in hazardous areas Features EATON

M-0. M-0... series control, monitoring and signalling devices. Ex e

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Safety Standards. Model Number:

7 Lighting Technology

SERIES 54 Inductive Proximity Sensor

Plug and Socket Devices SolConeX 16 A Series 8570

LED Linear Luminaire Series EXLUX 6402

The safety you rely on.

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Solenoid Operator 0513 / 1213

A good connection. International approvals.

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

EStrong-series Emergency Stop

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

ABG Cable Glands Installation Procedure

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Transcription:

SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected floodlights. Text in Bold is specific for emergency variants Overview 1 Safety Instructions 2 Installation 3 Maintenance 4 Technical Specification 5 Trouble Shooting 910-M-0094 Rev D Important information The SPARTAN series of explosion protected floodlights are specialist devices, certified for use in specific operating environments. The units must be installed in accordance with these instructions, must be correctly certified for the specific operating environment and must be installed by suitably qualified personnel. Emergency floodlights will require the fuse to be reconnected upon installation and the floodlight subjected to three 24 hour charge/discharge cycles to bring the battery up to peak capacity. If you have any queries about the installation or the certification of the unit please contact Raytec for immediate assistance and advice.

1. Safety instructions 1. Read this leaflet carefully before commencing to install the SPARTAN unit and retain it for future use. Installation can only be carried out by suitably qualified personnel. 2. Check the certification to ensure that the mains supply and the ambient temperature present is suitable for the unit being installed. 3. If the SPARTAN unit is to be installed in areas of high vibration, please consult with Raytec. 4. The SPARTAN unit housing is constructed from marine grade aluminium and toughened glass. The end user must ensure that these materials are suitable for the environment the SPARTAN unit will be installed in; Zone 1 and Zone 2 Hazardous areas. 5. Check certification nameplate on side of floodlight to ascertain type of threaded cable entry on the luminaire. Select suitably certified ATEX/IEC Ex cable glands and stopper plugs, these must be parallel thread, have a minium of 5 full thread engagement and be of a medium/fine tolerance to ISO965-1 and ISO965-3. The cable entry devices selected must maintain the IP rating of the luminaire 6. The incoming mains cable should not exceed a temperature rise of 20 C above the ambient conditions; select suitable cable.! 1.5m Isolate mains before removing cover Install in a well ventilated area Do not continually stare at lamp 2

2. Installation Mounting SPARTAN Unit 1. To meet the requirements of certification a MINIMUM of 2 fixing points must be used, the fixing points must be suitable for the conditions of use. Spartan 12 Floodlight Spartan 24 (Emergency Variant Shown) 3

Spartan 48 2. The unit may have been supplied with an integrated photocells. Care should be taken when positioning the unit to ensure the sensors are not shielded, is not pointing directly at another light source and is monitoring the general, prevailing light conditions. 3. The SPARTAN floodlight and the mounting bracket is supplied together as a unit. The bolts in the side of the housing shall be removed and used to secure the bracket to the SPARTAN housing, the bracket can be attached in the top or bottom position depending on the mounting application, where possible the cable glands should be kept to the bottom of the floodlight. It is very important that the red fibre washers are fitted between the SPARTAN housing and the mounting bracket. The unit must be aligned first before securing the bracket, on SPARTAN 24 and 48 units a locking screw is provided to lock the luminaire at various angles, the unit can be mounted horizontally or vertically allowing the unit to point up/down or left/right. 4

Typical wiring diagram standard luminaires Typical wiring diagram emergency luminaires 5

4. Wire the Mains cable into the terminal block. Provision has been made for this and identified as the E (Earth), L (Live), Ls (Live switched) and N (Neutral) terminals. There are two pairs of contacts for each of these to facilitate a mains cable that can be looped in and out of the unit. The Ls terminals on a standard unit is not electrically connected but allows them to be used on the same circuits as emergency floodlights. 5. Installer should earth the unit separately an internal and external earth point are provided as standard. 6. Connect wires to mains supply. 7. If the unit is opened for any reason, disconnect mains On emergency luminaires there may be more than one mains supply. 8. All SPARTAN floodlights have terminal blocks suitable for looping 4mm2 cable, only one cable should be connected to each terminal block connection. 9. Emergency SPARTAN floodlights may have a single green LED fitted adjacent to the incoming cable glands, when illuminated the green LED indicates that the emergency system is healthy. 10. The battery fuse located in the power supply lid on emergency variants is disconnected after final manufacturing testing. When installing the floodlight the battery fuse will need to be reconnected and the unit charged for 24 hours and then discharged (repeated 3 times) to bring the battery up to peak capacity. 11. If a 4 core cable is used on emergency luminaires L, Ls, N and E the link cable at the front of the terminal block between L and Ls should be removed. 12. During emergency operation the light output and duration will be determined by the variant purchased. 6

3. Maintenance 1. It is essential that all SPARTAN units are maintained in accordance with the requirements of the EN60079-17standard: (Electrical apparatus for explosive gas atmospheres other than mines). 2. IMPORTANT. No modifications are permitted to the unit, all spare parts must be purchased from the manufacturer, unauthorized modifications or spare parts will invalidate certification and make the equipment dangerous. 3. Isolate the SPARTAN unit from the mains supply and allow to cool before carrying out any maintenance work. 4. In the unlikely event of a number of LED s failing, the light engine assembly must be replaced. This is achieved by tilting the luminaire so that the LEDs are pointing upwards, removing the power supply cover, disconnect the white and violet cable to each power supply, remove the two M8 bolts at the rear of the casting, release the safety cable and pull the light engine assembly clear. Re fitting a light engine is a reversal of the above procedure. 5. The unit has 2 independent power supplies, in the event that a power supply needs to be replaced the cables to the LED and mains terminal block will need to be disconnected, the four M6 bolts released the power supply can then be removed. Fitting a new power supply is a reversal of the above procedure, please note that the power supplies are left handed or right handed and the correct variant will need to be ordered/fitted 6. Disposal of packaging, SPARTAN unit and old LED assemblies should be carried out in accordance with national regulations. 7

4. Technical Specification Spartan 12 Spartan 24 Spartan 48 Input Voltage 110-254V AC Consumption 30W max 60W max 120W max Consumption (Emergency variant) N/A 65W max 125W max Power Factor >0.95 Mains Frequency IP Rating 50/60Hz IP66/67 Weight Environment 5kg (11lbs) 9.5kg (20.9lbs) 19kg (41.9lbs) Weight Environment (Emergency variant) Dimensions Dimensions ATEX and IECEx Rating N/A 11.5kg (25.3lbs) 21kg (46.3lbs) See previous pages for line diagrams See below Protection/Certification II 2 GD Ex em IIC T4 or T5 Gb Ta -52 C to +55 C or II 2 GD Ex em IIC T6 Gb Ta -52 C to +48 C Ex tb IIIC T82 C Db IP66 & IP67 Ta = -52 C to +55 C 110V to 254V AC ONLY 8

5. Trouble Shooting 1. Ensure the two LED boards are correctly wired to terminal block. White to White : Violet to Violet 2. Ensure Mains input is correctly connected. 3. Ensure Mains Input is turned on at the source 4. On emergency variants check fuse to ensure it has not blown 5. If LED panel fails to light is it possible to identify if problem is with LED panel or power supply by swapping LED cables to opposite power supply to help identify problem. *For emergency variants add EM to the end of above codes (not available for FL12) 9

Spartan: White Light Part Code SPX-FL12-WHW-1010 SPX-FL12-WHW-3030 Description Spartan Flood, 12 LED, White-Light, 10 x10 Spartan Flood, 12 LED, White-Light, 30 x30 Max Lighting Distance* 93m 46m SPX-FL12-WHW-5050 Spartan Flood, 12 LED, White-Light, 50 x50 33m SPX-FL12-WHW-120120 Spartan Flood, 12 LED, White-Light, 120 x120 SPX-FL24-WHW-1010 Spartan Flood, 24 LED, White-Light, 10 x10 SPX-FL24-WHW-3030 Spartan Flood, 24 LED, White-Light, 30 x30 15m 132m 64m SPX-FL24-WHW-5050 Spartan Flood, 24 LED, White-Light, 50 x50 46m SPX-FL24-WHW-120120 Spartan Flood, 24 LED, White-Light, 120 x120 SPX-FL48-WHW-1010 Spartan Flood, 48 LED, White-Light, 10 x10 SPX-FL48-WHW-3030 Spartan Flood, 48 LED, White-Light, 30 x30 20m 187m 91m SPX-FL48-WHW-5050 Spartan Flood, 48 LED, White-Light, 50 x50 65m SPX-FL48-WHW-120120 Spartan Flood, 48 LED, White-Light, 120 x120 28m For emergency variants add -EM to the end of above codes (not available for FL12) For photocell variants add -PC to the end of the above codes *CCTV Camera use 10

Spartan: Infra-red Part Code Description Max Lighting Distance* SPX-FL12-I-1010 Spartan Flood, 12 LED, Infra-Red, 10 x10 230m SPX-FL12-I-3030 Spartan Flood, 12 LED, Infra-Red, 30 x30 112m SPX-FL12-I-5050 Spartan Flood, 12 LED, Infra-Red, 50 x50 80m SPX-FL12-I-120120 Spartan Flood, 12 LED, Infra-Red, 120 x120 52m SPX-FL24-I-1010 Spartan Flood, 24 LED, Infra-Red, 10 x10 325m SPX-FL24-I-3030 Spartan Flood, 24 LED, Infra-Red, 30 x30 158m SPX-FL24-I-5050 Spartan Flood, 24 LED, Infra-Red, 50 x50 113m SPX-FL24-I-120120 Spartan Flood, 24 LED, Infra-Red, 120 x120 73m SPX-FL48-I-1010 Spartan Flood, 48 LED, Infra-Red, 10 x10 459m SPX-FL48-I-3030 Spartan Flood, 48 LED, Infra-Red, 30 x30 224m SPX-FL48-I-5050 Spartan Flood, 48 LED, Infra-Red, 50 x50 160m SPX-FL48-I-120120 Spartan Flood, 48 LED, Infra-Red, 120 x120 103m For emergency variants add -EM to the end of above codes (not available for FL12) For photocell variants add -PC to the end of the above codes *CCTV Camera use 11

Typical Spare Parts: 24-48 variants Part Code Description SFL-PSUL-STD-T4 SFL-PSUR-STD-T4 SFL-PSUL-EMER-T4 SFL-PSUR-EMER-TR SFL-LE-MW-1010 SFL-LE-MW-3030 SFL-LE-MW-5050 SFL-LE-MI-1010 SFL-LE-MI-3030 SFL-LE-MI-5050 W300-PSU-GASKET-MF W300-GLASS-GASKET-MF W300-LIGHTENGINE-GASKET-MF W300-GLASS-MF PSU Left hand PSU Right hand Emergency PSU Left hand Emergency PSU Right hand White LED Assembly 10x10 White LED Assembly 30x30 White LED Assembly 50x50 IR LED Assembly 10x10 IR LED Assembly 30x30 IR LED Assembly 50x50 Gasket - Power Supply Gasket - Glass Gasket - LED Glass 12

Declaration Of Conformity With The Atex Directive 94/9/Ec Raytec Ltd. declares under our sole responsibility that the product(s) listed below conform with the relevant provisions of directive 94/9/EC of 23rd March 1994 Manufacturer Description of Equipment Raytec Ltd Unit 3, Wansbeck Business Park Rotary Parkway Ashington Northumberland NE63 8QW United Kingdom Spartan range of floodlights standard and emergency Notified Bodies Sira Certification Services (0518) Rake Lane Eccleston Chester CH4 9JN Certificate numbers Equipment Marking CML13ATEX3007 and CML14.0001 Quality Assurance Notification Sira 13 ATEX M592 IEC Ex Quality Assessment Report GB/SIR/QAR13.0018/00 II 2 GD Ex em IIC T4 or T5 Gb Ta -52 C to +55 C or II 2 GD Ex em IIC T6 Gb Ta -52 C to +48 C Ex tb IIIC T82 C Db IP66 & IP67 Ta = -52 C to +55 C 110V to 254V AC ONLY Emergency variants restricted to -20 o C 13

Compliance with the Essential Health and Safety Requirements has been assessed by reference to the following standards - IEC 60079-0 : 2012 IEC 60079-7 : 2007 IEC 60079-18 : 2009 IEC 60079-31 : 2009 And also 89/336/EEC Electromagnetic Compatibility Signed Name Position Barry Thompson Head of Hazardous Area Division Dated Serial number 14

DFT Middle East Tel: +9714 8878185 sales@dftme.com www.dftme.com SP/14/8.1