Zone 1 Linear Range - Installation Guide

Similar documents
Floodlight Range Installation Guide

Clarius EP PLUS LED FLOODLIGHT Installation Guide

ILED Aquarius Illuminated Windsock. User Manual

Operating Instructions

Operating Instructions

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Terminal Boxes in Stainless Steel SLS**.T

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

OPERATION AND MAINTENANCE INSTRUCTIONS

Operating Instructions

Linear fittings EVDL LED fitting - zones 21, & 22

ILED Dorado. User Manual

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Floodlight LED Series 6525

INSTRUCTION MANUAL (ATEX / IECEx)

Ex m Solenoid Operator Type 0519

Emergency Luminaire with LED Series EXLUX 6409/1

INSTRUCTION MANUAL (ATEX / IECEx)

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear Luminaire with LED Series EXLUX 6002

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

OPERATING INSTRUCTIONS

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Linear luminaire with LED Series EXLUX 6002

Floodlight LED Series 6525

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Linear Luminaire with LED Series EXLUX 6402/2

EXEL-L. Detail of the internal side. Transparent polycarbonate

IQL Helios Area-/Streetlight. User Manual

Floodlight LED Series 6125

VALIADIS S.A. HELLENIC MOTORS

Linear fittings EVNL LED fitting - zones 2, & 22

BMRX Series ROTARY LEVEL CONTROL

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

Position Switches Series 8074/2

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Leading the way in hazardous areas Features EATON

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

TECHNICAL BULLETIN. Sandvik MB670 Bolter Miners

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

LED Linear Luminaire Series EXLUX 6402

Type Electronic Limit Switch

Linear fluorescent luminaire LED V-CG-S

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/

Explosion protected terminal boxes type, GHG 72.

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

EX-REPAIR AND MAINTENANCE RECEPTACLES

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

CCAI, CCAIF, CCAIF..H

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

MANUFACTURED IN THE UK

Instruction Manual. Ex-Time 40 / 50

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Pendant Light Fitting IEC

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Flameproof Level Sensor (Flameproof F/S FP)

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PROTECTA III. Construction Tough glass reinforced polyester body

Position Switches Series 8070/2

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

Product manual cable glands type IR and IB. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Flameproof Alternators

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Easy and safe installation

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

ABG Cable Glands Installation Procedure

Position Switches Series 8060/2

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

MANUFACTURED IN THE UK

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Floodlight Series 6121

7 Lighting Technology

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Self-Exciting Flameproof Alternator

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

SynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

OPTIGAS 4010C Technical Datasheet

A good connection. International approvals.

Terminal Boxes Series 8125

Linear Luminaire with LED

Transcription:

Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text in italics specific for emergency variants. Overview 1 Safety Instructions 2 Installation 3 Maintenance 4 Technical Specification 5 Trouble Shooting Important information The SPARTAN series of explosion protected luminaires are specialist devices, certified for use in specific operating environments. The units must be installed in accordance with these instructions, must be correctly certified for the specific operating environment and must be installed by suitably qualified personnel. 920-M-0036 Revision D Emergency luminaires will require the fuse to be reconnected upon installation and the luminaire subjected to three 24 hour charge/discharge cycles to bring the battery up to peak capacity. If you have any queries about the installation or the certification of the unit please contact Raytec for immediate assistance and advice.

1. Safety instructions 1. Read this leaflet carefully before commencing to install the SPARTAN unit and retain it for future use. Installation can only be carried out by suitably qualified personnel. 2. Check the certification to ensure that the mains supply, ambient temperature present and T rating are suitable for the environment the unit is being installed in. 3. If the SPARTAN unit is to be installed in areas of high vibration, please consult with Raytec. 4. The SPARTAN unit housing is constructed from marine grade aluminium and polycarbonate outer optic. The end user must ensure that these materials are suitable for the environment the SPARTAN unit will be installed in; Zone 1 and Zone 2 Hazardous areas. 5. Check certification nameplate on cover of luminaire to ascertain type of threaded cable entry on the luminaire. Select suitably certified ATEX/IEC Ex cable glands and stopper plugs, these must be parallel thread, have a minimum of 5 full thread engagement and be of a medium/fine tolerance to ISO965-1 and ISO965-3. The cable entry devices selected must maintain the IP rating of the luminaire. 6. The incoming mains cable should not exceed a temperature of 27 C above the ambient conditions; select suitable cable.! 1.5m Isolate mains before removing cover Install in a well ventilated area Do not continually stare at lamp 2 www.raytecled.com UK / Europe Tel: +44 (0) 1670 520055

2. Installation Mounting SPARTAN Unit 1. To meet the requirements of certification a MINIMUM of 2 fixing points must be used, the fixing points must be suitable for the conditions of use. 2. The rear of the unit has 3 sets of blind M6/M8 fixing points, a full range of mounting accessories are available including a range of pole clamps, ceiling mount brackets, various wall mount brackets, outreach bracket and chain mount eyelets. Please consult www.raytecled.com for further details. 1414 FOR WL168 EMER 775 FOR WL84 STD AND EMER 1295 FOR WL168 STD 1635 FOR WL168-1500 STD 174 108 400 FOR WL84 700 FOR WL168/WL168-1500 3. When installing the SPARTAN luminaire vertically where possible, the cable glands should be kept to the bottom of the luminaire. UK / Europe Tel: +44 (0) 1670 520055 www.raytecled.com 3

4 www.raytecled.com UK / Europe Tel: +44 (0) 1670 520055

4. Wire the Mains cable into the terminal block. Provision has been made for this and identified as the E (Earth), L (Live), Ls (Live switched) and N (Neutral) terminals. There are two pairs of contacts for each of these to facilitate a mains cable that can be looped in and out of the unit, an identical terminal block is also available at the other end of the luminaire to allow the unit to be through wired. The Ls terminals on a standard unit is not electrically connected but allows them to be used on the same circuits as emergency luminaires. 5. Installer should earth the unit separately an internal and external earth point are provided as standard at each end of the luminaire 6. Connect wires to mains supply. 7. If the unit is opened for any reason, disconnect mains On emergency luminaires there may be more than one mains supply. 8. All SPARTAN luminaires have terminal blocks suitable for looping 4mm 2 cable, only one cable should be connected to each terminal block connection. 9. The battery fuse is located in the compartment that contains the battery, the fuse is disconnected after final manufacturing testing. When installing the luminaire the battery fuse will need to be reconnected and the unit charged for 24 hours and then discharged (repeated 3 times) to bring the battery up to peak capacity. 10. If a 4 core cable is used on emergency luminaires L, Ls, N and E the link cable at the front of the terminal block between L and Ls should be removed - see wiring diagram on previous page. 11. During emergency operation the light output and duration will be determined by the variant purchased. UK / Europe Tel: +44 (0) 1670 520055 www.raytecled.com 5

3. Maintenance 1. It is essential that all SPARTAN units are maintained in accordance with the requirements of the EN60079-17 Standard: (Electrical apparatus for explosive gas atmospheres other than mines). 2. IMPORTANT. No modifications are permitted to the unit, all spare parts must be purchased from the manufacturer, unauthorized modifications or spare parts will invalidate certification and make the equipment dangerous. 3. Isolate the SPARTAN unit from the mains supply and allow to cool before carrying out any maintenance work. 4. In the unlikely event of a number of LED s failing, the light engine assembly must be replaced. This is achieved by removing the outer polycarbonate cover and then releasing the 4 bolts that hold the LED assembly in place, disconnect the white and violet cable to the power supply and pull the light engine assembly clear. Re fitting a light engine is a reversal of the above procedure. 5. The unit has either 1 or 2 independent power supplies located in the terminal chamber covers, in the event that a power supply needs to be replaced the terminal chamber cover should be removed, the cables disconnected and the dog clip can then be detached from the cover. Fitting a new power supply is a reversal of the above procedure. 6. Disposal of packaging, SPARTAN unit and old LED assemblies/power supplies should be carried out in accordance with national regulations. 6 www.raytecled.com UK / Europe Tel: +44 (0) 1670 520055

4. Technical Specification WL84 STD (WL84-1200 STD) WL 168 STD (WL168-1500 STD) WL84 EMER WL168 EMER Input Voltage 110-254V AC or 18-30V AC/18-40V DC see certification nameplate on product Consumption 33W max 66W max 35W max 68W max Power Factor >0.95 Mains Frequency 50/60Hz IP Rating IP66/67 Weight 5kg - 11Ibs (WL84-1200 STD 8kg 17.6Ibs) 8kg 17.6Ibs (WL168-1500 STD 10kg 22Ibs) 7kg (15.4lbs) 10kg (22lbs) Dimensions See previous pages for line diagrams ATEX and IECEx Rating See below Protection/Certification CML14ATEX3119 or IEC Ex CML15.0001 II 2 GD Ex em IIC T4 & T5 Gb Ta up to -40 C to +55 C* II 2 GD Ex em IIC T6 Gb Ta up to -40 C to +45 C* Ex tb IIIC T75 C Db IP66 & IP67 Ta up to -40 C to +55 C* 110V to 254V AC ONLY or 18-30V AC/18-40V DC Emergency variants restricted operating temperature of -20 C to +50 C T4/T5 or -20 C to +40 C T6 UK / Europe Tel: +44 (0) 1670 520055 www.raytecled.com 7

5. Trouble Shooting 1. Ensure the two LED boards are correctly wired to terminal block. White to White : Violet to Violet. 2. Ensure Mains input is correctly connected. 3. Ensure Mains Input is turned on at the source. 4. On emergency variants check fuse to ensure it has not blown. 5. If the LED panel fails to light it is possible to identify if the problem is with the LED panel or power supply by swapping LED cables to opposite power supply to help identify problem. See sales literature for full list of ordering codes. 8 www.raytecled.com UK / Europe Tel: +44 (0) 1670 520055

Declaration Of Conformity With The Atex Directive 94/9/Ec Raytec Ltd. declares under our sole responsibility that the product(s) listed below conform with the relevant provisions of directive 94/9/EC of 23rd March 1994. Manufacturer Raytec Ltd Unit 3, Wansbeck Business Park Rotary Parkway Ashington Northumberland NE63 8QW United Kingdom Description of Equipment Spartan range of LED linear standard and emergency Notified Bodies Sira Certification Services (0518) Rake Lane Eccleston Chester CH4 9JN Certificate numbers CML14ATEX3119 or IEC Ex CML15.0001 Quality Assurance Notification Sira Equipment Marking II 2 GD Ex em IIC T4 or T5 Gb Ta -40 C to +55 C* or II 2 GD Ex em IIC T6 Gb Ta -40 C to +45 C* Ex tb IIIC T75 C Db IP66 & IP67 Ta = -40 C to +55 C* 110V to 254V AC ONLY or 18-30V AC/18-40V DC *Emergency variants restricted operating temperature -20 C to +50 C T4/T5 or -20 C to +40 C T6 UK / Europe Tel: +44 (0) 1670 520055 www.raytecled.com 9

Compliance with the Essential Health and Safety Requirements has been assessed by reference to the following standards - IEC 60079-0 : 2012 + A11 : 2013 IEC 60079-7 : 2007 IEC 60079-18 : 2009 IEC 60079-31 : 2009 And also 89/336/EEC Electromagnetic Compatibility. Signed Name Position Barry Thompson Director of Hazardous Area Division Dated Serial number 10 www.raytecled.com UK / Europe Tel: +44 (0) 1670 520055

UK / Europe Tel: +44 (0) 1670 520055 www.raytecled.com 11

UK / Europe T: +44 (0) 01670 520055 hazsales@raytecled.com Americas T: +1 613 270 9990 ushazsales@raytecled.com SPX/16/2.1 www.raytecled.com