BASYS Infrared Sensor Activated

Similar documents
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

BASYS Infrared Sensor Activated

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR-ACTIVATED LAVATORY FAUCETS

Optima ETF-600/ETF-610

INSTALLATION INSTRUCTIONS FOR ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR EAF-350 SERIES ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

ETF-600 Sensor Operated Lavatory Faucet

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC ACTIVE IR LAVATORY FAUCETS

G2 Optima Plus Flushometer

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED LAVATORY FAUCETS

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC INFRARED SENSOR ACTIVATED LAVATORY FAUCETS. Below Deck, Mechanical Below Deck, Thermostatic

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

Sloan Automatic Infrared Sensing Faucets

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

Maintenance Guide. OPTIMA Components:

Installation Instructions

G SERIES - E TOUCH MIXER / TAP

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

OPERATION & MAINTENANCE MANUAL 5000E Series Faucet

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

Installation Instructions

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND QUADRUPLE STATION SENSOR OPERATED SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS ELC-41000

Milano AUTOMATIC FAUCET

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

INSTALLATION INSTRUCTIONS

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

Installation Instructions

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

INSTALLATION INSTRUCTIONS

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

Royal. Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 10A. SLIP JOINT GASKETS AND RINGS

Installation Instructions

Installation Instructions

AquaSense ZTR Series

Royal Flushometer PARTS LIST

ELECTRONIC FLUSH VALVE FOR URINALS jupiter 2040

Royal Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Effective Date: May Rev. 1/9/2018- Void After: May Product: Lead Free Plumbing Products File No. 6905

Model 0393-(n)* AUTOMATIC DECK MOUNTED FOAM SOAP DISPENSER FOR EZFILL TOP FILL MULTIFEED KIT WITH 1.32 GAL. (5L) CONTAINER EZFILL FOAM SOAP DISPENSER

Installation Instructions

INFRARED TAPS. Important: Electronic taps saving water, saving power, promoting hygiene DB100 DB125 DB150 DB175 DBL200 DBL225 DBL250 DBL275

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

Advisory Bulletin. TB-99 Cleaning and Maintenance For Bobrick B-824 or B-828 Automatic Counter-Mounted Soap Dispensers B-824 B-828

LIGATURE RESISTANT SENSOR FAUCET

Installation Instructions

Installation For Service Only

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Installation Instructions

Installation Instructions

Single Handle Faucet, 4 Plate, Ceramic Cartridge, Extended Lever Handle with Pop-Up

Electronic Hand Washing Faucet

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

Dolphin Blue Infrared Taps

INSTALLATION INSTRUCTIONS PATIENCE

Installation Instructions

DOLPHIN INFRARED TAP DB800 / DB825 TECHNICAL HELPLINE DOLPHINSOLUTIONS.CO.UK DIAMETER PROJECTION TO SPOUT

Aqua-FIT Serio Series TM

Installation Instructions

Error code explanation Diagnostics...2 Error Code Chart...3 Tests Wiring diagram...6

Artec Pro Single Handle Commercial Kitchen Faucet

INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

Automatic Sensor Faucet Installation Manual CAT ALL-IN-ONE AUTO VALVE FAUCET HORIZONTAL WATER SPOUT. Revision

Alliance Towel Dispensing System. Operation Manual

INSTALLATION INSTRUCTIONS

MAC FAUCETS FA400 WALL MOUNT FAUCETS

MAC FAUCETS. FA400 Autoluxe Faucets

BC632 / BCL632 BC635 / BC635

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Installation Instructions / Warranty

EBF-550. Battery Powered Hand Washing Faucet

Installation Instructions / Warranty

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

EcoVantage AV. ZRK Dual Flush Series. Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

Installation Instructions / Warranty

Installation Instructions

Transcription:

EFX-1XX SERIES EFX-2XX SERIES 6C 6B 6A 5 3A 4 2 8 16 9 11 17 1 3B 7 PARTS LIST BASYS FAUCETS Item No. Code No. Part No. Description 1. Mid Mount Faucet Assembly Mid Mount Faucet Assembly with Mixer High Mount Faucet Assembly High Mount Faucet Assembly with Mixer 2. 3324104 EFX-1002-A 0.5 gpm/1.9 Lpm Multi-Lam Insert (includes insert, o-ring, 2.5 mm allen key and removal tool) 3324103 EFX-1001-A 1.5 gpm/5.7 Lpm Aerated Stream Insert (includes insert, o-ring, 2.5 mm allen key and removal tool) 3324102 EFX-1000-A 1.5 gpm/5.7 Lpm Laminar Stream Insert (includes insert, o-ring, 2.5 mm allen key and removal tool) 3A. 3324122 EFX-15-A 0.5 gpm/1.9 Lpm Solenoid Valve Caddy Assembly Mid Mount (Green) 3324123 EFX-16-A 1.5 gpm/5.7 Lpm Solenoid Valve Caddy Assembly Mid Mount (Blue) 3B. 3324124 EFX-17-A 0.5 gpm/1.9 Lpm Solenoid Valve Caddy Assembly High Mount (Green) 3324125 EFX-18-A 1.5 gpm/5.7 Lpm Solenoid Valve Caddy Assembly High Mount (Blue) 4. 0324019 EFX-19 Strainer (Filter) 5. 3324128 EFX-7-A Battery Pack Assembly 6A. 3324118 EFX-1-A Crown Assembly 6B. 3324119 EFX-3-A Solar Crown Assembly 6C. 3324120 EFX-4-A Solar Crown with LCD Assembly 7. Mixer Handle Assembly 8. 0324035 EFX-33 Handle Cap 9. 0335000 EAF-1 Faucet Mounting Kit (Pedestal) 10. 3325023 EAF-1008 13 (330 mm) Flexible Supply Hoses (2) 11. 3324101 EFX-26-A Trim Plate for 8 Centerset Sink 12. 3324100 EFX-20-A Trim Plate for 4 Centerset Sink 13. 0324027 EFX-27 Plug-in Voltage Adapter (US) EFX-28 Plug-in Voltage Adapter (EU) EFX-29 Plug-in Voltage Adapter (UK) 0335037 EAF-37 Box Type Voltage Adapter 14. 0335024 EAF-24-A 11-13/16 (300 mm) Extension Cable 0335025 EAF-25-A 47-1/4 (1200 mm) Extension Cable 0335015 EAF-17-A 126 (3200 mm) Extension Cable 15. 0335023 EAF-23-A Splitter 16. 3326009 MIX-60-A Mechanical, Below Deck Mixing Valve 17. 0326045 MIX-135-A Thermostatic, Below Deck Mixing Valve 18. 3365461 ETF-617-A Bak-Chek Tee NOTE: If changing flow rate caddy and spray insert must be changed in conjunction. in Item No. column = Not shown in illustration in Code No. and Part No. column = Not sold separately 18 10 12 Electrical Connection for up to Six (6) Faucets Using One (1) Adapter ADAPTER 15 14 13 DAISY CHAIN ELECTRICAL CABLE DAISY CHAIN ELECTRICAL CABLE TO ADDITIONAL FAUCETS (6 MAX.) 124

OPERATION As the user s hands enter the beam s effective range, the beam is reflected back into the sensor receiver and activates the solenoid valve allowing water to flow from the faucet. Water will flow until the hands are removed or until the faucet reaches its automatic time out limit setting. SET AND FIX TEMPERATURE AND ADJUST HOT LIMIT STOP Adjust lever to set temperature. Optional To fix temperature, set lever to the desired position, then remove lever and plug hole with Cap. Optional Hot Limit Stop Adjustment To adjust the hot/ cold mix (factory set at 50/50) remove the lever. Check to make sure dot is in center position before beginning adjustment. Faucet may be adjusted in 10º increments. 2 mm 2 mm Steps to Default IR Function Activate Function Setting Clic IR Activation Cover IR clic approximately for 2 sec. until LED will flash 1x - then remove finger from IR clic (Active for 5 sec.) Cleaning IR activation; Cover IR clic 2x - confirmation 2 min. Mode of the function is active by a couple flashes by the LED; to return to normal operation cover IR clic 1x or the faucet will automatically return to normal function after 2 min. 12/24 Line See below. Off Off Purge 12HR Feature 24HR Sensor See page 123. 6 1-8 Range Adjustment Reset IR activation; Cover IR clic 2x; LED will flash 5x Manually Electronics Cover IR clic 1x for 5 sec. until LED flashes 4x, then remove finger from IR clic Wait for 20 sec. (After 10 sec. water will flow for 6 sec. and automatically adjust to environment) Security Off After 90 seconds (max) of hand and/or object On within sensor appears permanent, waterflow will stop and will remeasure environment Please contact factory for more extensive programming options. 12/24 LINE PURGE FEATURE This feature will operate the faucet every 12 or 24 hours since last use, if not used to prevent stagnant water conditions. Default purge duration is two minutes. Consult factory regarding other timing options. IR activation (see above). Cover IR clic approximately 24 sec. (ignore LED indications during this period). Release when requested program is reached. (See diagram to right). Programming mode will time out after 2 minutes if no changes are made. 1x 24 sec +......1x Deactivate Activate 12HR...2x Activate 24HR...3x 125

SENSOR RANGE ADJUSTMENT Factory setting is appropriate for the majority of applications and should not require resetting unless under extreme situations. IR Activation (see previous page).to enter programming mode place finger on IR clic for 2 times then remove. Light on side of crown should blink to indicate programming mode. BATTERY REPLACEMENT NOTE: Replace Battery when LED1 indicator flashes red each time faucet is in use or when faucet stops functioning. LED1 is identified by the battery symbol. NOTE: Turning off water is not necessary. Remove crown by loosening hex screw located on underside of spout and slide crown down and lift off. faucet body and will not fall out. Cover IR clic until LED flashes 4x - hold on until LED flashes 1x to 8x, from minimum to maximum. See diagram below. Release when requested range is reached. 6x - Factory Setting 5x 7x 4x 8x 3x 1x 2x Remove battery pack assembly by lifting out of spout. Open battery pack assembly by pushing in tabs on side of assembly. SPARE FILTER Wait, until LED flashes. Remove all four (4) AA-cell batteries from battery pack. Insert four (4) NEW AA-cell batteries into battery pack assembly cartridge. NOTE: Insure batteries are installed with proper polarity. The cover of the case indicates polarity of batteries. Improper polarity will not harm the faucet. Improper polarity will cause the faucet not to operate. Replace cover of the battery pack assembly and reinsert assembly into faucet. Slide on crown and secure. 126

REPLACING THE SOLENOID STRAINER (FILTER) NOTE: Turning off water is not necessary, due to integrated automatic stop valve. Remove crown by loosening hex screw located on underside of spout and slide crown down and lift off. faucet body and will not fall out. Insert new solenoid caddy at a 45 angle. Rotate solenoid caddy clockwise to align with arrow, locking the unit and opening water path. Reinsert battery pack assembly. Remove battery pack assembly by lifting out of spout. SPARE FILTER SPARE FILTER Slide on crown and secure. Rotate solenoid assembly counterclockwise through a 45º angle. Pull solenoid caddy from faucet. NOTE: STRAINER (FILTER) CAN BE REMOVED, CLEANED AND REPLACED AT THIS TIME. 127

REPLACE SPRAY INSERT NOTE: Turning off water is not necessary, due to integrated automatic stop valve. Remove crown by loosening hex screw located on underside of spout and slide crown down and lift off. faucet body and will NOT fall out. Retrieve spray removal tool located near the spray insert. Insert spray removal tool into spray slot by sliding hook end of key between faucet spout and insert. Pull insert out of faucet once hooked. Install new insert. NOTE: If changing to a different flow rate solenoid caddy must be changed in conjunction. Return spray removal tool to storage location. NOTE: This can only be done once spray head is installed. This will lock the spray head in place. NOTE: If spray head is inserted incorrectly key will not lock in properly. Turn faucet on to push insert out and re-install. Slide on crown and secure. 128

UPGRADE FAUCET FUNCTIONALITY Remove crown by loosening hex screw located on underside of spout and slide crown down and lift off. faucet body and will NOT fall out. Place new crown on faucet by sliding onto spout and tightening hex screw on underside of spout. NOTE: All electronics are fully encapsulated in the crown and thus protected from the environment and easy to replace or upgrade. LED DISPLAY DIAGNOSTIC CODES COLOR LEDs BLINKING LED1 LED3 LED2 COLOR LEDs ON Function LED1 LED2 LED3 Description 1 Description 2 Start Up Boot LED1 and LED2 alternate blinking Fast Toggle Battery Check after Start Up LED1 on for 2 sec, if battery greater than 3.5V Line Power Check after Start Up LED3 on for 2 sec, if line power greater than 3.5V IR Adjust Process LED1 blinking while IR adjusts Few seconds IR Adjust IR LED2 on for 2 sec, if adjustment OK Battery Low LED1 blinks 3x, if battery is less than warning level Only while in detection mode Battery Empty LED1 double flashes 3x, if battery is less than empty level Only while in detection mode Valve Error LED3 double flashes 3x, if valve current error; flash after the 3rd error, off after the 3rd good operation Flashes after the 3rd error, off after the 3rd good operation IR Activation LED2 on for 2 sec, if IR-click has been activated After 5 sec. automatically back to operating mode Cleaning Mode LED1 4-in-1 flash, if cleaning mode is activated During Cleaning Mode is activated Permanent 4-in-1 flashes 129

TROUBLESHOOTING GUIDE 1. Red LED in spout does not blink 2 sec after battery installation. A. Battery placement incorrect or batteries have been discharged. B. Ensure batteries are installed properly. Check the orientation of each battery matches the positive (+) and negative ( ) symbols shown on the battery compartment. 2. Faucet DOES NOT function. A. Adhesive packaging label affixed over sensor eye. B. Remove adhesive label from sensor eye. 3. Faucet delivers water in an uncontrolled manner. A. Faucet is not working properly. B. Clean sensor window. If continually now working contact Sloan s Tech Support Department. 4. Faucet DOES NOT deliver any water when sensor is activated. INDICATOR: Solenoid valve produces an audible CLICK. A. Water supply stop(s) closed. Open water supply stop(s). B. Strainer is clogged. Remove, clean, and reinstall strainer. Replace strainer, if needed (refer to page 124). INDICATOR: Solenoid valve DOES NOT produce an audible CLICK. A. Batteries low (battery-powered models). Replace batteries (refer to battery replacement on page 123). B. Power failure (hardwire models). Check power supply. 5. Faucet delivers only a slow flow or dribble when sensor is activated. A. Water supply stop(s) are partially closed. Completely open water supply stop(s). 6. Faucet DOES NOT stop delivering water or continues to drip after user is no longer detected. A. Faucet is not working properly. B. Clean sensor window. If continually now working contact Sloan s Technical Support (see below). 7. LED indicator blinks when faucet is in use. A. Batteries low (battery-powered models). B. Replace batteries (refer to battery replacement on page 123). 8. The water temperature is too hot or too cold on a faucet connected to hot and cold water supply lines. A. Supply stops are not adjusted properly. Adjust supply stops. B. For models with integral side mixing valve mixing valve is set improperly for the water temperature desired. Rotate mixing valve handle clockwise to decrease water temperature or counterclockwise to increase water temperature. C. Inadequate hot water supply. Adjust supply stops. CARE AND CLEANING DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean Faucets that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, protect the Faucet from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating. When assistance is required, please contact Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614). 130