Current transformers

Similar documents
CT current transformers Ip/5 A ratio

Electrical network management. Schneider Electric. Acti 9 iem2000 Technical Datasheet

The PowerLogic wireless range is designed to retrofit existing switchboards, and enhance energy efficiency of buildings in operation for many years.

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution

Single-phase CT current transformers Cat. Nos :

TeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

TeSys Enclosed Starters. Let TeSys watch over your machinery

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

BC IMPREGO Impregnated dry type transformers and autotransformers

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

I B D Q I B D Q O I B D Q O

Manual Motor Starters. Meta-MEC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

Essential equipment for all your requirements

Maximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops

Simple and smart power factor correction

AF40... AF96 3-pole contactors Technical data

FMotor Circuit Controllers

Industrial Contactors CTX 3 3P 185A - 800A

Wiring devices Asfora 2015 catalogue

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Current transformers. Current transformers

Fuse holders and fuses

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

PHOENIX CONTACT

D509E. Manual Motor - Starters

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

Selection Guide. Control Circuit and Load Protection

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Square D General Purpose Relays

PLSES 4500 IMfinity Platform. IP23 high-speed induction motors Industrial refrigeration Variable speed Frame size 225 to to 480 kw

Short form catalogue. Motor protection & control

MCset 17.5 kv. Civil engineering guide April Medium Voltage Distribution

Electrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices

AE 9... AE 40 Contactors NE... Contactor Relays

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

M-0. M-0... series control, monitoring and signalling devices. Ex e

CBGS-0. Medium voltage distribution

3 - Protection components Motor circuit-breakers

SIRIUS 3RU2 Thermal Overload Relays

NH-Fuse system Low voltage

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Differential Pressure Sensors

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

Medium Voltage Distribution FBX. Assembling a 1250A busbar Instructions.

Protection Equipment. 5/2 Introduction

DX³ RCCBs - ID 4P up to 100 A

Green approach to fuel savings

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Application Description

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Simply reliable. ABB Single-phase Transformers. When transformation means safety and control.

ZS4-SF1 Screw Clamp Terminal Block

Technical Information

Easy Choice for Energy Efficiency

Differential Pressure Sensors

EVI 5 S13 Solenoid System

Junction boxes for control, monitoring and control panel Ex tb

Solenoid coils VACF Type codes

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

EMPAC Metal enclosed capacitor bank for wind applications

Galaxy VX Battery Breaker Trip Board (GVXBBTB) and Battery Breaker Capacitor Board (GVXBBCB)

Control Circuit Protection

DBL distribution blocks 3x1 pole

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

TeSys D Green. Catalogue 2017 AC/DC compatible coil contactors. schneider-electric.com

SG-B1 SERIES / SG-A1 SERIES

Modular contactors and relays

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Solenoid coil for control in potentially explosive areas Type BZ

30Compact 200 A / 360 A

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Tel: &

BETA Switching Switches and Light Indicators

ZK6 PI-Spring Terminal Blocks Feed-through

Transcription:

FUNCTIONS AND CHARACTERISTICS Current transformers Technical Datasheet Schneider Electric is the global specialist in energy management with the most complete power monitoring product line. Current Transformers are essential components designed to be used with Schneider Electric's extensive power monitoring product portfolio. From simple energy meters to world class power quality meters, these proven products satisfy any requirement. PB119870 PB119864 PB100316-35 056852NMD-2 056854NMD-2 METSECT5CC04 METSECT5MB025 METSECT5CYL1 METSECT5GD025 METSECT5HA025 PLSED310169EN 1

DB416186 Ip/5 A ratio Application diagram of a CT. The Ip/5 A ratio current transformer delivers at the secondary a current (Is) of 0 to 5 A that is proportional to the current measured at the primary (Ip). This allows them to be used in combination with measurement equipment: Ammeters. Kilowatt-hour meters. Measurement units. Control relays. etc. When the primary is energized, the measurement equipment nearly acts as a short circuit which keeps the secondary voltage very low. This voltage will increases significantly if the short circuit is removed. CT selection - conductor rating aspects The choice depends on the conductor profile and the maximum intensity of the primary circuit. CT with let-through primary Conductor type Suggested Current Transformer and mounting Cable Mixed, bars or cables Vertical or horizontal bars Vertical bars DB415986 DB415920 DB415988 DB415989 DB415921 DB415987 Ratings (A) 40 to 250 150 to 800 200 to 4000 5000 to 6000 CT internal profile Type C Type M Type D (1) Type V FF C FF MA MA MB MC FF D MD VV (1) Two secondary connectors (parallel internal wiring - only one secondary winding) for easier cable access. 1 lateral + 1 on one extremity. Warning: only one must be used at a time. Specific mounting: use of cylinder A cylindrical metallic spacer ensures a proper CT positioning when the conductor or the CT cannot be positioned perpendicular. Secured by bolt + nut. CT with primary connection by screw and nut (example: use of cylinder with bar or cable) DB416005 DB416006 FF V2 FF MD NOTE: This document is not intended to be used as an installation guide. METSECT5CYL1 (aluminium) 16550 (brass) 2 PLSED310169EN

CT selection - Electrical aspect Ip/5 A We recommend that you choose the ratio immediately higher than the maximum measured current (In). Example: In = 1103 A; ratio chosen = 1250/5. For small ratings: From 40/5 to 75/5 and for an application with digital devices, we recommend that you choose a higher rating, for example 100/5. This is because small ratings are less accurate and the 40 A measurement, for example, will be more accurate with a 100/5 CT than with a 40/5 CT. Specific case of the motor starter: to measure motor starter current, you must choose a CT with primary current Ip = Id/2 (Id = motor starting current). Validation of measurement solution according to accuracy class It consists in controlling the right adaptation of the CT on the accuracy class aspect. The accuracy class is specified in the project. The total dissipated power of the measurement circuit (meter + cables) should not be superior to the specified limit of the CT. This limit is for different standard classes. If necessary, the choice of the cable section, the CT or meter should be modified to fit the requirement. Copper cable cross-section (mm 2 ) 1 1 1.5 0.685 2.5 0.41 4 0.254 6 0.169 10 0.0975 16 0.062 Power per doubled meter at 20 C (VA) Schneider Electric device Ammeter 1.1 72 x 72 / 96 x 96 Analog ammeter 1.1 Digital ammeter 0.3 PM8000 0.15 PM3000 0.3 PM5000 iem3000 Consumption of the current input (VA) For each temperature variation per 10 C bracket, the power drawn up by the cables increases by 4 %. Application example Project specification: 200 A, in Ø27 mm cable, accuracy class 1. Our choice is METSECT5MA020. For this CT selected on the chart (next page), the max acceptable power is 7 VA (for "Accuracy class 1" which is specified in the project). FF ME Internal profile type MA Cables (mm) Bars (mm) Ø27 10 x 32 15 x 25 Rating Ip/5 A (A) Commercial reference number Accuracy class 0.5 1 3 Max. power (VA) 150 METSECT5MA015 3 4-200 METSECT5MA020 4 7-250 METSECT5MA025 6 8-300 METSECT5MA030 8 10-400 METSECT5MA040 10 12 - Control of the conformity of the measurement chain: bbpm3000 multi-meter: 0.3 VA. bb4 meters of 2.5 mm 2, doubled wires: 0.41 x 4 = 1.64 VA. Total: 0.3 + 1.64 = 1.94 VA (< 7 VA) Conclusion: this CT is well adapted as the accuracy class will be even better than 1. Hazard Label PLSED310169EN 3

PB112463 PB112460 PB112461 PB112446 METSECT5CCppp METSECT5MBppp METSECT5MAppp PB112462 PB118085 METSECT5MCppp FF MD FF MC FF MA FF MB FF CC Type C - solid core current transformer (cable profile) Internal profile type CC Cables (mm) Bars (mm) Rating Ip/5 A (A) Commercial ref number Ø21-40 METSECT5CC004 50 METSECT5CC005 60 METSECT5CC006 75 METSECT5CC008 100 METSECT5CC010 125 METSECT5CC013 150 METSECT5CC015 200 METSECT5CC020 250 METSECT5CC025 Type M - current transformers (mixed: cable/bar profile) MB MA MC MD Ø26 12 x 40 15 x 32 Ø27 10 x 32 15 x 25 Ø32 10 x 40 20 x 32 25 x 25 Ø40 12 x 50 20 x 40 250 METSECT5MB025 300 METSECT5MB030 400 METSECT5MB040 150 METSECT5MA015 200 METSECT5MA020 250 METSECT5MA025 300 METSECT5MA030 400 METSECT5MA040 250 METSECT5MC025 300 METSECT5MC030 400 METSECT5MC040 500 METSECT5MC050 600 METSECT5MC060 800 METSECT5MC080 500 METSECT5MD050 600 METSECT5MD060 800 METSECT5MD080 See your Schneider Electric representative for complete ordering information. METSECT5MDppp 4 PLSED310169EN

DB415927 DB415926 Mounting plate installation. DIN rail mounting. Type C - solid core current transformer (cable profile) Internal profile type Common characteristics Secondary current Is (A) 5 A Maximum voltage rating Ue (V) 720 V Frequency (Hz) 50/60 Hz Safety factor (sf) 40 to 4000 A: sf y 5 5000 to 6000 A: sf y 10 Degree of protection IP20 Operating temperature tropicalised range -25 C to +60 C (1) relative humidity > 95 % Storage temperature -40 C to +85 C Compliance with standards IEC 61869-2 VDE 0414 Secondary connection (as per model) by terminals for lug by tunnel terminals by screws (1) Warning: some products are limited to +50 C. Accuracy class Overall dimensions Fastening mode Accessories 0.5 1 3 (refer to drawing pages for details) Cylinder Max. power (VA) W x H x D (mm) PB112451 PB112452 FF CC FF MB FF MA FF MC FF MD CC Dimension (mm) Commercial ref no. MB MA MC MD - - - 1.25 1 1.5 44 x 66 x 37 bb Adapter for DIN rails. bb Mounting plate. - 1.25 2-1.5 2.5 2 2.5 3.5 2.5 3.5 4 3 4 5 4 5.5 6 5 6 7 3 4-60 x 85 x 63 bb Adapter for DIN rails. 4 6 - bb Mounting plate. 6 8-3 4 4 7 - - 56 x 80 x 63 bb Adapter for DIN rails. bb Mounting plate. 6 8-8 10-10 12-3 5 5 8 - - 70 x 95 x 65 bb Adapter for DIN rails. bb Mounting plate. 8 10-10 12-12 15-10 12-4 6-70 x 95 x 65 bb Adapter for DIN rails. 6 8 - bb Mounting plate. 8 12-16550 METSECT5CYL1 Included - METSECT5COVER METSECT5CYL2 METSECT5COVER - METSECT5COVER - METSECT5COVER See your Schneider Electric representative for complete ordering information. NOTE: This document is not intended to be used as an installation guide. PLSED310169EN 5

PB112467 FF V2 Type V - current transformers (vertical bar profile) Internal profile type VV Cables (mm) Bars (mm) Rating Ip/5 A (A) Commercial reference number - 55 x 165 5000 METSECT5VV500 g 6000 METSECT5VV600 g METSECT5VVppp PB112454 PB112456 PB112458 METSECT5DAppp METSECT5DCppp METSECT5DEppp PB112455 PB112457 PB112459 METSECT5DBppp METSECT5DDppp METSECT5DHppp Type D - current transformers (vertical or horizontal bar - dual secondary terminals) DA 32 x 65 400 METSECT5DA040 500 METSECT5DA050 600 METSECT5DA060 800 METSECT5DA080 1000 METSECT5DA100 1250 METSECT5DA125 g 1500 METSECT5DA150 g DB - 38 x 127 1000 METSECT5DB100 1250 METSECT5DB125 g 1500 METSECT5DB150 g 2000 METSECT5DB200 g 2500 METSECT5DB250 g 3000 METSECT5DB300 g DC - 52 x 127 2000 METSECT5DC200 g 2500 METSECT5DC250 g 3000 METSECT5DC300 g 4000 METSECT5DC400 g DD - 34 x 84 1000 METSECT5DD100 1250 METSECT5DD125 g 1500 METSECT5DD150 g DE - 54 x 102 1000 METSECT5DE100 1250 METSECT5DE125 g 1500 METSECT5DE150 g 2000 METSECT5DE200 g DH - 38 x 102 1250 METSECT5DH125 g 1500 METSECT5DH150 g 2000 METSECT5DH200 g g Operating temperature: -25 C to 50 C See your Schneider Electric representative for complete ordering information. 6 PLSED310169EN

FF V2 Type V - solid core current transformers (vertical bar profile) Internal profile type Accuracy class Overall dimensions Fastening mode Accessories 0.5 1 3 (refer to drawing pages for details) W x H x D Cylinder Sealable cover Max. power (VA) (mm) VV Dimension (mm). 60 - - 175 x 273.5 x 110 bb Insulated locking screw. - Included 70 - - Type D - solid core current transformers (vertical or horizontal bar - dual secondary terminals) DA Dimension (mm) 4 8-90 x 94 x 90 bb Insulated locking screw. Included 8 10-8 12-12 15-15 20-15 20-20 25 - DB 6 10-99 x 160 x 87 bb Insulated locking screw. - Included 8 12-10 15-15 20-20 25-25 30 - DC 25 30-125 x 160 x 87 bb Insulated locking screw. - Included 30 50-30 50-30 50 - DD 10 15-96 x 116 x 87 bb Insulated locking screw. - Included 12 15-15 20 - DE 12 15-135 x 129 x 85 bb Insulated locking screw. - Included 15 20-20 25-20 25 - DH 12 15-98 x 129 x 75 bb Insulated locking screw. - Included 12 15-20 25 - g Operating temperature: -25 C to 50 C See your Schneider Electric representative for complete ordering information. PLSED310169EN 7

Solid core CT dimensions CC internal profile type MB internal profile type DB416965 MA internal profile type MC internal profile type DB415922 DB415939 MD internal profile type DA internal profile type DB416966 DB415932 DB internal profile type DC internal profile type DB416967 DB416968 DB415923 8 PLSED310169EN

Solid core CT dimensions contd. DD internal profile type DE internal profile type DB416969 DB416970 DH internal profile type DB416971 VV internal profile type DB416972 NOTE: This document is not intended to be used as an installation guide. PLSED310169EN 9

Solid core cylinders dimensions Cylinders METSECT5CYL1 METSECT5CYL2 DB416004 DB416002 Aluminium Aluminium 16550 16551 DB416082 DB416000 Brass Brass Covers METSECT5COVER DB416008 10 PLSED310169EN

Split core CTs Hazard Label Common characteristics Cable CT Bus Bar CT Secondary current Is (A) 5 A 5 A Maximum voltage rating Ue (V) 720 V 720 V Frequency (Hz) 50/60 Hz 50/60 Hz Safety factor (sf) up to 1000 A: sf y 5 greater than 1000 A: sf y 10 up to 1500 A: sf y 5 greater than 1500 A: sf y 10 Degree of protection IP20 IP20 Operating temperature -5 C to +50 C relative humidity 5-85 % -5 C to +40 C relative humidity 5-85 % Storage temperature -25 C to +70 C -25 C to +70 C Compliance with standards IEC 61869-1 IEC 61869-2 IEC 61869-1 IEC 61869-2 Secondary connection (as per model) by terminals for lug by tunnel terminals by screws by terminals for lug by tunnel terminals by screws Split core CT CT internal profile Type H Type G FF C HA HD HG HJ HP FF V2 GA GD GG GJ FF HM HM PLSED310169EN 11

Split core CTs PB119866 PB119864 PB119862 METSECT5GAppp METSECT5GDppp Type G - split core current transformers (bus bar) GA GD GG GJ Accuracy class Max power (VA) 0.5 1 3 CT window dimension (mm) Rating Ip/5A (A) Commercial Reference no. - - 1.25 23 x 33 100 METSECT5GA010 - - 1.5 150 METSECT5GA015 - - 2.5 200 METSECT5GA020-1.5-250 METSECT5GA025-3.75-300 METSECT5GA030 1 - - 400 METSECT5GA040-1.5-55 x 85 250 METSECT5GD025-2.5-300 METSECT5GD030 1 - - 400 METSECT5GD040 2.5 - - 500 METSECT5GD050 2.5 - - 600 METSECT5GD060 2.5 - - 750 METSECT5GD075 2.5 - - 800 METSECT5GD080 5 - - 1000 METSECT5GD100-1.5-85 x 125 250 METSECT5GG025-2.5-300 METSECT5GG030-2.5-400 METSECT5GG040 2.5 - - 500 METSECT5GG050 2.5 - - 600 METSECT5GG060 2.5 - - 750 METSECT5GG075 2.5 - - 800 METSECT5GG080 5 - - 1000 METSECT5GG100 5 - - 1200 METSECT5GG120 7.5 - - 1250 METSECT5GG125 7.5 - - 1500 METSECT5GG150 10 - - 85 x 165 1000 METSECT5GJ100 10 - - 1200 METSECT5GJ120 10 - - 1500 METSECT5GJ150 10 - - 1600 METSECT5GJ160 10 - - 2000 METSECT5GJ200 10 - - 2500 METSECT5GJ250 15 - - 3000 METSECT5GJ300 15 - - 4000 METSECT5GJ400 See your Schneider Electric representative for complete ordering information. METSECT5GGppp PB119868 METSECT5GJppp 12 PLSED310169EN

Split core CTs contd. PB119870 PB119872 PB119874 METSECT5HAppp METSECT5HDppp METSECT5HGppp Type H - split core current transformers (cable) HA HD HG HJ HM HP Accuracy class Max power (VA) 0.5 1 3 CT window dimension (mm) Rating Ip/5A (A) Commercial Reference no. - 1-18.4 x 19 150 METSECT5HA015-1.5-150 METSECT5HA020 1 - - 250 METSECT5HA025-1 - 27.9 x 27 250 METSECT5HD025-1.5-300 METSECT5HD030-2.5-400 METSECT5HD040 1 - - 500 METSECT5HD050 - - 1.5 Ø32.5 100 METSECT5HG010 - - 2.5 125 METSECT5HG013 - - 3 150 METSECT5HG015 - - 3 200 METSECT5HG020 - - 3 250 METSECT5HG025-2.5-300 METSECT5HG030-5 - 400 METSECT5HG040-5 - 500 METSECT5HG050-5 - 600 METSECT5HG060-2.5-42.4 x 43 300 METSECT5HJ030-5 - 400 METSECT5HJ040-5 - 500 METSECT5HJ050 2.5 - - 600 METSECT5HJ060 2.5 - - 750 METSECT5HJ075 2.5 - - 800 METSECT5HJ080-2.5-42.4 x 85 300 METSECT5HM030-5 - 400 METSECT5HM040-5 - 500 METSECT5HM050 2.5 - - 600 METSECT5HM060 2.5 - - 750 METSECT5HM075 2.5 - - 800 METSECT5HM080-1.5 - Ø44 250 METSECT5HP025-2.5-300 METSECT5HP030-5 - 400 METSECT5HP040-5 - 500 METSECT5HP050-5 - 600 METSECT5HP060-5 - 750 METSECT5HP075-5 - 800 METSECT5HP080-5 - 1000 METSECT5HP100 See your Schneider Electric representative for complete ordering information. PB119876 PB119878 PB119880 METSECT5HJppp METSECT5HMppp METSECT5HPppp PLSED310169EN 13

FUNCTIONS AND CHARACTERISTICS Split core CT dimensions Gx products GA Dimensions GD Dimensions PB119867 PB119863 GG Dimensions PB119869 PB119865 GJ Dimensions 14 PLSED310169EN

FUNCTIONS AND CHARACTERISTICS Split core CT dimensions contd. Hx products HA Dimensions HD Dimensions HG Dimensions HJ Dimensions PB119875 PB119877 PB119871 PB119873 PLSED310169EN 15

FUNCTIONS AND CHARACTERISTICS Split core CT dimensions contd. HM Dimensions HP Dimensions PB119879 PB119881 16 PLSED310169EN

FUNCTIONS AND CHARACTERISTICS Rogowski CTs PB118060 METSECTR30500 PowerLogic Rogowski Current Transformer Main METSECTR30500 METSECTR46500 METSECTR60500 METSECTR90500 Range Product or component type Accessory / part category Range compatibility Current transformer type Complementary Electrical connection Cable Current range PowerLogic Current transducer Measurement accessory PowerLogic EM3500 - EM3555A EM3502A EM3560 EM3550A EM3560 EM3561A PowerLogic EM4200 - EM4236 EM4235 Acti9 iem3000 - iem3555 iem3565 Flexible core Flying lead 2.4 m 600 V AC max, voltage L-N sensed conductor 1000 V AC UL style 21223 cable with 22 AWG leads 50 A to 5000 A Network frequency 50/60 Hz Measurement accuracy Installation category ±1 % from 50 A to 5000 A 600 V AC Cat IV Pollution degree 2 Dimensions METSECTR30500 METSECTR46500 METSECTR60500 METSECTR90500 CT core thickness 8 mm diameter 8 mm diameter 8 mm diameter 8 mm diameter CT core length (open) 300 mm 460 mm 600 mm 900 mm Diameter (closed) 96 mm 146 mm 191 mm 287 mm Environment Standards EN 61010-1, UL 61010-1, EN 61010-2-032, UL 61010-2-032 Product certifications Ambient air temperature for operation CURus UL recognized -15 ºC to 60 ºC Ambient air temperature for storage -40 ºC to 70 ºC Humidity range Altitude Protection degree 0 to 95 % non-condensing 2000 m max IP67 Commercial Reference Numbers METSECTR25500 METSECTR30500 METSECTR46500 METSECTR60500 METSECTR90500 Powerlogic - Rogowski current transformer, 250 mm CT core length, 80 mm dia. CT, rope, 600 V AC, 5 ka Powerlogic - Rogowski current transformer, 300 mm CT core length, 96 mm dia. CT, rope, 600 V AC, 5 ka Powerlogic - Rogowski current transformer, 460 mm CT core length, 146 mm dia. CT, rope, 600 V AC, 5 ka Powerlogic - Rogowski current transformer, 600 mm CT core length, 191 mm dia. CT, rope, 600 V AC, 5 ka Powerlogic - Rogowski current transformer, 900 mm CT core length, 287 mm dia. CT, rope, 600 V AC, 5 ka PLSED310169EN 17

Schneider Electric Industries SAS 35, Rue Joseph Monier, CS 30323 F - 92506 Rueil Malmaison Cedex RCS Nanterre 954 503 439 Capital social 896 313 776 www.schneider-electric.com Current Transformers PLSED310169EN As standards, specifications and designs develop from time to time, please contact Schneider Electric for confirmation of the information given in this document. Design: Schneider Electric Photos: Schneider Electric Over 75 % of Schneider Electric products have been awarded the Green Premium ecolabel. 2019 - Schneider Electric - All rights reserved. 02-2019 DB410174