ELECTRICAL POWER GUIDE INTERNATIONAL EDITION

Similar documents
TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

PARTS CATALOG MODEL FBD352 DISPENSER

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

Installation and Operation Instructions

Manual Transfer Switch

IOA Expansion Cabinet. Dual Line Cords Upgrade Instructions

FLO Home TM G5 Model. Installation guide

ASSEMBLED BY HAND IN THE USA

Three-Phase Pole Mounted Recloser

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

SYSTEM CONTROL KIT. Model: CK-41F. Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances.

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120

ELECTRONIC FIREPLACE DAMPER

Safety Sentry Electronic Breakaway Switch

INSTALLATION MANUAL. Contour & Contour LX Pedicure Chairs. Contour. Contour LX Rev B 5/11/18

USER MANUAL (1 of 2)

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

Quick Connection Cabinet (QCC)

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

PSX-240 Enclosed Autotransformer Installation Manual

Temporarily Approved Solar Photovoltaic System Electrical Schematics

Positive Displacement Pump

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Sivoia QED R Installation Instructions Please Leave for Occupant

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

USER MANUAL Installation, Operation, and Maintenance

Pre-Installation Guide Performer

PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

LU23, LU28 & LU29 Series Quick Start

Installation, Operation & Maintenance Manual Control Panels for Automatic Self-Cleaning Strainers Model 596 and Model 2596

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

UV DISINFECTION UNIT MODEL 3G

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

Installation Manual & Warranty

USER MANUAL SELO. INNOVATION Series. Gas-Fired Hot Water Boilers. Natural Gas Modulating, Condensing Hot Water Boiler Models

Model 8144NC Fresh Air Ventilator

Installation Guide. Marine Filter SURT023M SURT024M

User s Guide Includes Mounting, Installation, and Product Registration

6. Electrical. 7. Settings. 8. Quick

HarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual

LU27 Series Quick Start

Installation Instructions

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Model LA 4300 Time Delay OFF Controller

ESC Series Engine Shutdown Control

USER MANUAL BENCHMARK Gas-Fired Boiler. Benchmark 6000 Boiler Installation, Operation & Maintenance Manual

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Snap-Trol 183 Nema 1 Series

SINGLE PHASE WIRING SPECIFICATIONS

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

THREE PHASE WIRING SPECIFICATIONS

MODEL 908. Read Instructions Carefully! Fuel Gauge CURTIS INSTRUMENTS, INC.

i n s t r u c t i o n m a n u a l

RS-110 Rainfall Sensor Installation Guide

A-dec 311 Dental Chair and Related Systems

INSTALLATION INSTRUCTIONS For Model 855 Wolo Express TM

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

Installation Guide High-end dynamic balancing instrumentation Page 1. Installation Guide for. EasyBalance 2.2

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Model LA 4100 Time Delay OFF Controller

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

PATTERSON PUMP COMPANY

Updated: October 2012

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Installation Manual. Rev

Electro-Mechanical Swing Operator. Table of Contents

AirStar Tandem Installation Kit Part Number 85694

SPECIFICATIONS SRF

Usage Instructions of Solar Control for 3Way-Ball Valve

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

PARTS CATALOG MODEL FBD56X SERIES FROZEN BEVERAGE DISPENSERS (INCLUDES AFCTM PARTS)

Slip Ring Connection Board Version 1.0 User s Manual

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

Patient Care Facility

Air-Cooled Scroll Compressor Chillers Models AGZ 010A to AGZ 034A Models AGZ 026B to AGZ 130B. Revised Electrical Data Tables.

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

ClassicSeries Compressor Installation

FW-IOB-T-120/208VAC Input/Output/Bypass Assembly. Installation Instructions

Model C230 Pump Controller

Model APS 3B Snow and Ice Melting Control

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

SPECIFICATIONS SR

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

Transcription:

ELECTRICAL POWER GUIDE INTERNATIONAL EDITION INNOVATION Gas-Fired Hot Water Boilers Natural Gas Modulating, Condensing Hot Water Boiler Models: INN800 INN1060 INN1350 Technical Support: (Mon Fri, 8am-5pm EST) 1-800-526-0288 www.aerco.com Latest Revision: 02/23/2017 DISCLAIMER The information contained in this manual is subject to change without notice from AERCO International, Inc. AERCO makes no warranty of any kind with respect to this material, including, but not limited to, implied warranties of merchantability and fitness for a particular application. AERCO International is not liable for errors appearing in this manual, nor for incidental or consequential damages occurring in connection with the furnishing, performance, or use of these materials. 02/23/2017 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 1 of 5

1 GENERAL Innovation (INN) Gas Fired Hot Water Boilers are fully factory wired and packaged units which require simple power wiring as part of the installation. This technical guide is intended to help designers provide electrical power wiring (line voltage) to Innovation units. Control wiring details are provided in other publications depending on the intended application. This document is intended as a guide only, and cannot include all alternatives, situations, or be totally inclusive. To comply with all codes and authorities having jurisdiction, designers and installers must plan the electrical wiring carefully and execute the installation completely. Emergency shutoffs, fusible fire switches, break glass stations, and other electrical requirements should be considered and installed whenever necessary. 2 Hot Water Boiler Electrical Requirements Innovation Hot Water Boilers require the following electrical supply: 220 volts, single phase, 50 Hz, 15 Amps Refer to Figure 1 for typical electrical shutoff disconnect switch location. ELECTRICAL SHUTOFF DISCONNECT SWITCH Figure 1. Service Switch Typical Location The distribution block for field connection is located in the upper right of the control box (see Figure 2). All copper wire must be connected to the terminal distribution block. Voltages lower than the rated input will result in increased wear and premature failure of the blower motor. Wire size and type should be made per the National Electrical Code based on length and load. 02/23/2017 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 2 of 5

Figure 2 shows the location of the Power Box containing the terminal block connections. The Power Box is accessed by removing the front panel of the unit. TERMINAL BLOCK Power Box Shown With Cover Removed POWER BOX Figure 2. Power Box and Terminal Block Location All units that operate with a 220 VAC power source include a 220 VAC to 120 VAC transformer. This transformer is installed inside the unit, as shown in Figure 3, and is pre-wired. The 220 VAC electrical connection is made in the Power Box (see Figure 2). 220 VAC to 120 VAC TRANSFORMER Figure 3. 220V Transformer Front Frame & Panel and Side Panels Removed 02/23/2017 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 3 of 5

3 Provisions for Service Designers must provide emergency shutoffs and other devices to satisfy electrical codes. It is also recommended to provide an electrical shutoff disconnect switch of suitable load carrying characteristics on or near each Hot Water Boiler. No electrical boxes or field components should be mounted to the surface of the unit or where they would interfere with the removal of the side or top panels for maintenance. The disconnect switch should be mounted near the unit as illustrated in Figure 1. Wiring conduit, EMT, or other wiring paths should not be secured to the unit, but supported externally. Electricians should be instructed as to where the wiring conduit should be located, such as away from the relief valve discharge, drains, etc. All electrical conduit and hardware should be installed so that it does not interfere with the removal of any cover, inhibit service or maintenance, or prevent access between the unit and walls or another unit. 4 Unit Wiring A dedicated protected circuit should be provided from the power source to the unit. No other electrical devices should be permanently wired on the same circuit. An emergency switch (electrical shutoff) must be in series with the power to the unit. Refer to Figure 4 for the wiring connections to the terminal block contained in the unit s Power Box. 5 Multiple Unit Wiring Whenever multiple units are installed within the same mechanical spaces, electrical code requirements call for a single electrical shutoff for emergency use. It is the responsibility of the electrical designer to comply with local codes and regulations affecting an individual installation. TERMINAL BLOCK IN POWER BOX DISCONNECT SWITCH SINGLE-POLE, 10 AMP 220V/1/50Hz 1 POLE 10 AMP CIRCUIT BREAKER GND L2/N L1 Figure 4. 220V/1 /50 Hz Wiring Schematic 02/23/2017 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 4 of 5

Change Log Date Description 05/18/2015 Rev A: Initial Release 02/23/2017 Rev B: PIR 1177-8: Added 220 VAC to 120 VAC transformer Chris Blair AERCO International, Inc., 2017 02/23/2017 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 5 of 5