Installation Instructions SELECTRONIC Proximity Infection Control Faucet 0 / 0 / 0 Infection Control Faucet shown Installed on American Standard. Infection Control Sink Certified to comply with ASME A..M 0 American Standard MODEL NUMBERS 0. 0. 0. Product No.'s & Options Specifications How to Install - Electrical Hook-up - Maintenance - FAQ,s Replacement Parts NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S. customer's e-mail us at: faucetsupport@amstd.com For Parts, Service, Warranty or other Assistance, please call -00-- (In Canada: -00--0) (In Toronto Area only: -0-0)
Thank you for selecting American-Standard...the benchmark of fine quality for over 0 years.to ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. UNPACKING All American Standard Faucets Are Water Tested At Our Factory. Some Residual Water May Remain In The Faucet During Shipping.. Remove the fitting and loose items from the carton. The illustration below shows the fitting and all loose items after they have been removed from the carton. Some items may be packaged partially assembled to other items.. Selectronic Spout Assembly. Mounting Kit. Electrical Enclosure. Supply Hose a. DC Power Supply (for 0 series) b. AC Power Supply (for 0 series). Circuit board. " Deck plate ( optional must be ordered separately). " Deck plate ( optional must be ordered separately). Mixing Valve ( optional must be ordered separately). Installation Instructions. ft. Extension Wire (0 series) 0. 0. 0. a DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE. s e P r o d SELECTRONIC Proximity Infection Control Faucet MODEL NUMBERS 0. 0. 0. 0 / 0 Infection Control Faucet shown Installed on American Standard. Infection Control Sink Certified to comply with ASME A..M Product No.'s & Options Specifications How to Install - Electrical Hook-up - Maintenance - FAQ,s Replacement Parts 0 American Standard M R E V.. NOTE TO INSTALLER: Please give this manual to the customer after installation. u c Base Product t Single Hole Sink Single Inlet a I n s t a l l a t i o n I n s t ru c t i o n s PRODUCT No.s B How to order the Selectronic Product. Choose Power Supply. Choose Desired Spout " GN Spout b 0P00 Deck Plate Deck Plate (optional) and Hole Sinks Single Inlet To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S. customer's e-mail us at: faucetsupport@amstd.com For Parts, Service, Warranty or other Assistance, please call -00-- (In Canada: -00--0) (In Toronto Area only: -0-0) 0P00 Mixing Valve Mixing Valve (optional) and Hole Sinks Hot and Cold Inlets 0XTMV M R E V..
Roughing-in Dimensions GENERAL DESCRIPTION: Electronic faucet with proximity operation. Vandal resistant solid brass construction single post mounting. Operates on DC (battery) or AC permanent power. In-line strainer for solenoid is integral. Single inlet / compression, built-in checks, and flexible stainless steel -/" reach inlet hose for spout connection. (mm) -/" DIA. (mm) " (mm) -/" (mm) -/" MOUNTING SURFACE mm (-/) DIA. 0mm (-/) MAX. mm (-/) mm (-/) mm (-/) mm (-/) 00mm (0") mm (0) /" COMP. RECOMMENDED TOOLS Channel Locks Adjustable Wrench Plumbers' Putty or Caulking Phillips Screwdriver Flat Blade Screwdriver Electric Drill & /" Drill Bit Tape Measure ' INSTALLATION Fig. INSTALL SPOUT ASSEMBLY; Fig. CAUTION Turn off hot and cold water supplies before beginning. Insert WIRES (), FLEX HOSE () and SPOUT SHANK () through center hole of mounting surface. Fig... Assemble "C" WASHER (), STAR WASHER () and LOCKNUT () onto threads of SPOUT SHANK () from underside of mounting surface. Fig. a.. Align FAUCET and tighten LOCKNUT (). Fig. a. Fig. a Note: " and " Deck Plates are available for other installations, see page one for information.
MOUNT ENCLOSURE; Fig. NOTE. The illustration shows the Infection Control FAUCET mounted on the American Standard Infection Control Sink. Faucet can be installed on almost any sink or countertop. For Faucet installation on the American Standard Infection Control Sink, see instruction sheet No. 0-0 (Infection Control Sink System) supplied with Sink for more detailed information.. For installation on Infection Control Sink mount ENCLOSURE () on MOUNTING BRACKET () with SCREWS (). Fig. MOUNTING BRACKET " (mm) " (mm) ENCLOSURE MOUNTING HOLES -/" (mm). For all other sinks or countertops determine location of ENCLOSURE (). It must be located within the " (mm) by " (mm) shaded area shown in Figure in order for electrical connections from the spout assembly to be completed. NOTE: ENCLOSURE SUPPLY HOSE is 0". Distance between wall supply and ENCLOSURE () must be taken into consideration.. Remove screws from COVER () and pull off COVER (). Hold the ENCLOSURE () in desired location and mark the four mounting hole locations as shown. Fig... The ENCLOSURE () works best if secured to a wall stud or cross brace within the wall, using the SCREWS () supplied. If the ENCLOSURE () is to be installed on a tile or plaster wall the ANCHORS () and SCREWS () should be used. Fig... For installations on drywall or tiled walls; use ANCHORS () and SCREWS () for securing ENCLOSURE () to finished wall. Drill four /" dia. holes a minimum of -/" deep. Insert the four ANCHORS () flush with face of the finished wall. Align the ENCLOSURE () and Install the MOUNTING SCREWS (). Tighten to secure ENCLOSURE () to mounting surface. CONNECT SPOUT HOSE TO ENCLOSURE; Fig.. Connect SUPPLY NUT () from spout assembly to nipple on top of ENCLOSURE (). Tighten with adjustable wrench to make a water tight connection. Fig.. CONNECT WATER SUPPLY TO ENCLOSURE AND WALL SUPPLY; Fig. NOTE; If using the optional Mixing Valve See Sheet #M0 for installation instructions.. Insert FIBER WASHER () into SUPPLY NUT () on ENCLOSURE ().. Connect SUPPLY NUT () on ENCLOSURE () to FLEXIBLE SUPPLY HOSE (). Tighten to make a water tight connection. Use two wrenches to tighten if necessary. Fig.. SUPPLIES WASTE MOUNTING BRACKET " (mm) 0" (00mm) -/" (mm) NOTE: If using Mixing Valve (optional) See Sheet #M0 for installation instructions. Fig. Fig. Fig. a OTHER SINK INSTALLATION mm (0). Connect FLEXIBLE SUPPLY () directly to wall supply. Connection on FLEXIBLE SUPPLY () is /" compression. Use adjustable wrench to tighten connection. Do not over tighten. Fig. a. Note: FLEXIBLE SUPPLY () measures 0" from the bottom of the ENCLOSURE () base. If additional supply length is required, installer must purchase parts separately. Important: If FLEXIBLE SUPPLY () is too long, loop to avoid kinking. COLD WATER OR TEMPERED WALL SUPPLY
ELECTRICAL INSTALLATION Fig. DC VERSION (BATTERY); Fig.. Remove ENCLOSURE COVER (). Fig... Feed the WIRE CONNECTORS () through the top of ENCLOSURE (). Fig. a.. Remove GROMMET () from ENCLOSURE (). Fig... Feed the gray SENSOR WIRE () through GROMMET (), " from CONNECTOR. Fig. b & d Insert gray SENSOR WIRE () into SPLIT PLUG (). Push SPLIT PLUG () into GROMMET () to seal. Fig. d.. Insert GROMMET () back into ENCLOSURE (). Fig. c. Fig. a Fig. b ". Install BATTERY () onto DC circuit board. Fig.e. Note: For BATTERY PACK installation see "Install Battery" page.. Install CIRCUIT BOARD () into ENCLOSURE () with SENSOR WIRE () under BOARD. Fig. c.. Insert SENSOR WIRE CONNECTOR () into CIRCUIT BOARD RECEPTOR (). Fig. e. Fig. c BLACK RED. Connect wires from SENSOR to SOLENOID VALVE () (Red to +, Black to -). Fig. c.. Replace ENCLOSURE COVER (). Tighten cover screws firmly. Fig. d Fig. e
AC VERSION; Fig. Fig. CAUTION Before opening ENCLOSURE disconnect AC power supply.. Remove ENCLOSURE COVER (). Fig... Feed the WIRE CONNECTORS () through the top of ENCLOSURE (). Fig. a.. Remove GROMMET () from ENCLOSURE (). Fig... Feed the gray SENSOR WIRE () through GROMMET (), " from CONNECTOR. Fig. b. Insert gray SENSOR WIRE () into SPLIT PLUG (). Push SPLIT PLUG () into GROMMET () to seal. Fig. e. Fig. a Fig. b ". Insert GROMMET () back into ENCLOSURE (). Fig. d.. Remove SPLIT PLUG () from POWER SUPPLY GROMMET (). Insert POWER CORD CONNECTOR () through POWER SUPPLY GROMMET (). Insert POWER CORD () into SPLIT PLUG (). Push SPLIT PLUG () into POWER SUPPLY GROMMET () to seal. Fig. g.. Insert POWER SUPPLY CONNECTOR () into RECEPTOR () on the CIRCUIT BOARD (). Fig. c.. Install CIRCUIT BOARD () into ENCLOSURE () with SENSOR WIRE () under BOARD. Fig. d.. Insert SENSOR WIRE CONNECTOR () into CIRCUIT BOARD RECEPTOR () slot. Fig. f. Fig. c Fig. e POWER SUPPLY CORD Fig. d BLACK RED. Connect wires from SENSOR to SOLENOID VALVE () (Red to +, Black to -). Fig. d.. Replace ENCLOSURE COVER (). Tighten cover screws firmly. Fig. g Fig. f
Fig. Unit # Unit # Unit # TWO PIECE GROMMET " FOR AC-VERSION (MULTI HOOK-UP); Fig.,. See AC Version Electrical Hook-up for first unit of the Multi hook-up.. Remove ENCLOSURE COVERS from all ENCLOSURES. Fig. a TWO PIECE GROMMET. Remove SOLID BLACK INSERT() from right side of ENCLOSURE # and replace with gray -PIECE GROMMET (). Replace solid black inserts on Unit # with gray -PIECE GROMMET ().. Take the ft. EXTENSION () from Unit # and install into right side of Unit # and Left side of Unit # insealing wire into SPLIT PLUG () as shown in Fig. a. Push SPLIT PLUG () into GROMMET ().. Insert CONNECTOR from ft. EXTENSION () into CIRCUIT BOARD RECEPTOR () top of Unit # as shown in Fig... Insert other end of ft. EXTENSION into LOWER U GROMMET () of Unit # (approximately " from connector). Fig.. Push SPLIT PLUG () into GROMMET () to seal.. Insert connector of ft. EXTENSION into lower receptor as shown in fig. on CIRCUIT BOARD () of Unit #.. Feed gray sensor wire from Unit # through upper U GROMMET () of Unit # ENCLOSURE " from connector Fig.. Insert wire into SPLIT PLUG (). Push SPLIT PLUG () into GROMMET () to seal. Fig. a. Feed the gray ft. EXTENSION () through ROUND GROMMETS () and U GROMMETS () as illustrated above. Fig. b BLACK RED. Insert GROMMET () back into ENCLOSURE. Fig. b.. Reinstall Circuit Board () into Enclosure with all wires under Board. Fig. b.. Connect Unit # Red and Black Sensor wires To # solenoid valve (Red to +, Black to -). Fig. b.. Repeat Steps through for remaining Units in Multi Hook-up.
TEST INSTALLED FAUCET TO ENSURE A LAMINAR WATER FLOW the air must be slowly purged from the spout. To do so, cover the SENSOR () while slowly opening the water supply valves. When the water flows as a solid, smooth, steady stream, uncover the SENSOR () and fully open the water supply valve. Fig.. MAINTENANCE HOW TO CHANGE SENSOR RANGE; (Factory set at ") Fig.. Setting the Detection Zone (Distance): Fig.. Detection Zone: " - " (0mm - 0mm) Default: Set at Factory " (0mm) Remove cover from ENCLOSURE. Disconnect GRAY SENSOR WIRE () from circuit board, then reconnect. Fig.. Fig DETECTION ZONE. While the SENSOR CONTROL LED () is blinking slowly, place your hand - in. (0-0mm) in front of the sensor. Fig. a.. When the LED stops blinking and stays "ON", move your hand to the desired position and hold in place until the LED begins to blink again. Fig. a. Fig.. Once the SENSOR CONTROL LED () begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. Fig. a. HAND WASH SENSOR OPERATION; When the Sensor detects a user, the water immediately starts to flow. Water flow will stop Two seconds after user is out of sensor range. The off delay allows the user to comfortably move his hands without the flow cycling on to off. As a precaution, a safety timer will turn off the water, after the sensor has been blocked for seconds. The water will stay off until the blockage is removed from the detection zone. HOW TO INSTALL AND CHANGE BATTERY; Fig.. To install New BATTERY () align and press down BATTERY () (contacts facing downward) into position until tabs lock into place.. To remove the BATTERY () spread the two tabs on the HOLDER () with your thumbs. The BATTERY () will release. Fig. a " - " (0mm - 0mm BLINKING LED BLINKING LED Fig. Fig. BATTERY HOLDER LOCKING TABS UP TO " (0mm). Remove the OLD BATTERY ().. Install NEW BATTERY () (contacts facing downward) into HOLDER () and press down into position until tabs lock into place. Fig.
HOW TO CLEAN FILTER; Fig. CAUTION Before opening ENCLOSURE disconnect AC power supply.. Remove ENCLOSURE COVER. Fig.. Close SUPPLY STOP () with mm Hex wrench. Note: Keep water flowing out of faucet while shutting off.. Pull off Red () and Black () CONNECTORS from SOLENOID VALVE ().. Unthread STRAINER () using a /" socket.. Pull out the STRAINER () and clean with an old toothbrush. Rinse thoroughly with water. CLEAN SCREENS. Install the STRAINER () back in its place and tighten with a /" socket. Caution: do not over tighten strainer. Note: It is recommended to clean strainer every months.. Replace ENCLOSURE COVER. Tighten cover screws firmly. HOW TO CLEAN AND REMOVE THE FLOW RESTRICTOR; Fig. Fig.. Remove SET SCREW () with FLAT BLADE SCREWDRIVER (). Pull off SPOUT () from faucet base. Fig. & a. REMOVE SET SCREW (). Remove HOUSING () and remove FLOW RESTRICTOR (). Fig. b.. Rinse clean FLOW RESTRICTOR (). Reassemble and install into SPOUT BASE (). Reassemble SPOUT () onto SPOUT BASE () and tighten SET SCREW (). Fig.. Fig.a Fig.b PULL UP TO REMOVE SPOUT
GENERAL CLEANING; Fig. Fig.. For general cleaning use a damp, soft cloth to clean the spout and the sensor.. For cleaning dirt use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth. CAUTION Do not scratch the sensor when cleaning. Avoid using anything that may scratch the spout surface. Never use polishing power, detergent or a nylon scrub brush. They will damage the surface of the spout or Sensor. FAQ'S Q: How will I know if battery needs to be replaced? A: Valve does not open and sensor blinks times interrupted by pause for up to days. Q: Why has the flow rate of the faucet reduced significantly? A: Check and clean aerator and strainer. Q: There is no flow out of faucet when I'm in the sensor range? A: Check sensor. If sensor blinks times interrupted by pause, replace battery, or call 00--. Q: Why does the faucet operate the opposite of expected-turns On when not in sensor range, but turns off when in sensor range? A: Sensor wires to solenoid are reversed. Black to - & Red to + is correct. Q: What is the normal operating pressure range? A: Faucet will operate with supply pressures ranging from 0-0 psi.
A-000A SPOUT SCREW KIT M-000A " SPOUT KIT M-000A FLOW RESTRICTOR KIT SELECTRONIC Proximity Infection Control Faucet MODEL NUMBERS 0. 0. 0. A-000A BATTERY VCR-P M-000A SENSOR KIT A-000A FAUCET SUPPLY HOSE M-000A MOUNTING KIT M-000A MOUNTING SCREW KIT A0-000A WASHER A-000A SUPPLY HOSE A-000A ft. MULTI EXTENSION WIRE M00-000A DC SOLENOID VALVE ASSEMBLY M0-000A AC SOLENOID VALVE ASSEMBLY A0-000A DC CIRCUIT BOARD A0-000A AC CIRCUIT BOARD Appropriate finish code CHROME 00 0P00 A-000A SOLENOID SCREWS A-000A SOLID GROMMET 0P00 0-000A MOUNTING NUT M-000A SOLENOID & SCREWS A00-000A FILTER A-000A ROUND GROMMET A00-000A SUPPLY STOP A-000A U GROMMET HOT LINE FOR HELP For toll-free information and answers to your questions, call: (00) - Weekdays :00 a.m. to :00 p.m. EST IN CANADA -00--0 (TORONTO -0-0-) Weekdays :00 a.m. to :00 p.m. EST Product names listed herein are trademarks of American Standard Inc. American Standard Inc. 0 M0-000A POWER SUPPLY A0-000A POWER SUPPLY GROMMET