PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

Similar documents
PH60 Series Premium ph Testers

PH20 Value ph Tester Instruction Manual

EC1 Pocket Conductivity Tester Instruction Manual

EC20 Pocket Conductivity Tester Instruction Manual

Salt 1 Pocket Salinity Tester Instruction Manual

TDSscan10M Pocket TDS Tester Instruction Manual

COM-100 EC / TDS / TEMPERATURE METER

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

PHscan30S Pocket ph Meter Instruction Manual

PHscan10S Pocket ph Tester Instruction Manual

Bante220 Portable ph Meter Instruction Manual

ECscan20 Pocket Conductivity Tester Instruction Manual

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

Large Display ph Pens , , Instruction Manual

ORPscan20 Pocket ORP Tester Instruction Manual

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

Marin Control Digital

ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED

TRACER. POCKETESTER ä ORP CODE 1742

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

HI Portable Waterproof Skin ph Meter INSTRUCTION MANUAL

Tracer ORP PockeTester TM Code 1742

User Manual Pocket Pro, Pro + ph

SoilStik ph Meter PRODUCT MANUAL. Item # 2105

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

MODEL IQ150 ph Meter Getting Started TWO-POINT CALIBRATION--QUICK REFERENCE GUIDE

SERVICE MANUAL STARTER 2100 Bench ph Meter STARTER 3100 Bench ph Meter STARTER 3100C Bench ph Meter

Sunleaves TDS Expert Plus

HanTron Model HT-3P. Manual. Installation Maintenance Repair Manual

Care and use guide. Contents. page

WalkLAB Digital Dissolved Oxygen meter HD9030

Care and use guide Guía de uso y cuidado Guide d utilisation et d entretien.

Instruction Manual Portamess 911 Cond

Operator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)

TABLE OF CONTENTS. Firmware Version

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

Instruction Manual PORTABLE ph METER D-71

Model P772 Conductivity Meter. User Manual

Visit us at

OCS Series. High Resolution Digital Crane Scale. User Guide

INSTRUCTION MANUAL. Mi490 Peroxide value. Milwaukee Lab Photometer. Test Equipment Depot Washington Street Melrose, MA 02176

INSTRUCTION MANUAL. Handy Polaris

OPERATION MANUAL PEN TYPE. Model: 8690 DESIGN PATENTED: US D S

Breath Alcohol Tester

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

ELPRO Lepenik & Co. d.o.o., Ob gozdu 7c, Rogoza, 2204 Miklavž na Dravskem polju, Slovenija tel:

MoistureMatch A next generation grain tester

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Atlas 5. Instruction Manual. Handheld Indoor Air Quality Monitor. Measures CO2, Temperature and Humidity DISTRIBUTED BY

Care and use guide. Contents. page

ortable ph, Conductivity & DO2 Meters

Visit us at

Model 2053 Conductivity Meter Instruction Manual

STARTER 2000 Bench ph Meter Instruction Manual

Signet V(D) to V(D) PVDF Conductivity Electrodes

Digital Formaldehyde Meter

Wireless Tire Pressure and Temperature Monitoring System Instruction Manual Model #: TM-507 SCE 507 Commercial Cap Sensors with Monochrome Display

Dawson DSM170 Multi-Function Moisture Meter User s Manual

Instruction Manual. ph Meter D-51

Dual Axis Magnetic Field (Axial and Radial) Sensor

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

4&5 RANGE CONDUCTIVITY METERS Operation Instructions

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

Global Water Instrumentation, Inc.

PLATINUM. PREMIUM CLASS pocket scale. Manual & Operation Guide

Conductivity Measurement CLM 280

HI Free Chlorine Meter

HI Ethylene Glycol Refractometer INSTRUCTION MANUAL

TABLE OF CONTENTS. Introduction

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

Care and use guide. Contents. page

HI 96707C Nitrite Low Range ISM

ACCURACY RELIABILITY SIMPLICITY

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Wireless Tire Pressure and Temperature Monitoring System Color Display Manual. Wide Screen Color Display Model #: TST-507-D-C

Flue Gas Analyzer IMR 1100F

User's Guide. CO 2 Meter. Model CO250

User Guide. Model Insulation Tester / Megohmmeter. Introduction

AT8020. Breath Alcohol Tester. Using manual. Ver:HW

Breath Alcohol Tester

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes

THREE RANGE DS METERS Operation Instructions

HI 8510-HI 8512 HI 8710-HI 8711 HI 8720-HI HI HI

Weighing Scale IDS-802. User Manual

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02

Grain Moisture Meter. Operators manual

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

Intelligent torque meter tester

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

Phase Sequence Tester

Operation and Maintenance Manual

DPS280 / DVS280 Series

TABLE OF CONTENTS 11.0 WARRANTY

User s Manual. Model PH71 Personal ph Meter IM 12B03D01-01E. IM 12B03D01-01E 3rd Edition

TABLE OF CONTENTS 10.0 LIMITED WARRANTY

Coating Thickness Gauges

3 40W. Product Introduction. 1440mm(56.7in) 560mm (22in) 440mm (17.3in

Transcription:

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual APERA INSTRUMENTS, LLC www.aperainst.com V6.4

Thank you for purchasing Apera Instruments PC60 Premium Multi-Parameter Tester. Please carefully read this instruction manual before using the product in order to have an accurate and reliable test result, and avoid unnecessary damages to the meter or probe. For video tutorials, please go to support.aperainst.com Contents 1. Battery Installation... 3 2. Keypad Functions... 3 3. Complete Kit... 4 4. Preparation Before Use... 4 5. ph Calibration... 5 6. ph Measurement... 6 7. Conductivity Calibration... 7 8. Conductivity Measurement... 7 9. Parameter Setting... 9 10. Technical Specifications... 10 11. Icons and Functions... 11 12. Probe Replacement... 11 13. Warranty... 12 2

1. Battery Installation Please install batteries according to the following steps. *Please note direction of batteries: All POSITIVE SIDES ( + ) FACING UP. (Wrong installation of batteries will cause damage to the tester and potential hazards) + + - - + + - - 2. Keypad Functions 1 Pull the battery cap up 2 Slide the battery cap along to the direction of arrow 3 Open the battery cap 4 Insert the batteries (ALL POSITIVE SIDES FACING UP) (see graph) 5 Close the battery cap 6 Slide and lock the battery cap along to the direction of arrow 7 Fit the tester s cap while making sure to push all the way down. The tester s waterproof design may be compromised if the cap is not fitted correctly. Short press------ < 2 seconds,long press------- > 2 seconds 1.Short press to turn on the tester and long press to turn off the tester. 2.When turned off, long press to enter parameter setting. 3. In measurement mode, short press to turn on backlight. 1.In measurement mode, short press to switch parameter ph COND TDS SAL 2.In mode setting, short press to change parameter (Unidirectional) 1. Long press to enter calibration mode. 2. In calibration mode, short press to confirm calibration. 3.When measured value is locked, short press to unlock; Battery LCD Buttons Probe Ring Probe Cap Probe ph Sensor BPB Sensor 3

3. Complete Kit Diagram - 2 4. Preparation Before Use If it is first-time use or the tester hasn t been used for a long time, pour some 3M KCL solution in the probe cap (about 1/5 of the probe cap) and soak the probe for 15-30 minutes. When not in use, we recommend store the ph probe in the storage 3M KCL solution in the probe cap to keep the sensor s accuracy. But even if stored dry, it won t do any permanent damage to the sensor. It will only temporarily cause the probe to lose its sensitivity, which can always be restored by soaking in the storage solution. The storage solution is 3M KCL (potassium chloride). One bottle of 10mL storage solution comes with the tester kit. If the soaking solution was contaminated, please replace with new ones timely. * DO NOT use any other brand s storage solutions because different chemicals may be used and potential permanent damage could be caused to the meter. 4

5. ph Calibration Things needed in addition to what s in the box: A clean cup, distilled water (8-16oz), and tissue papers for rinsing and drying the probe. 5.1 Short press to turn on the meter; rinse the probe in distilled water, shake the meter in the air and use tissue paper to dap off excess water (never rub or wipe the sensor). 5.2 Pour certain amount (about half volume of the calibration bottle) of ph 7.00 and ph 4.00 buffer solution in separate calibration bottles; 5.3 Long press to enter calibration mode; Short press to exit. 5.4 Dip the probe in ph7.00 buffer solution, stir gently, and allow it to stand still in the buffer solution until a stable reading is reached. When stable icon displayed on the LCD screen (as shown in Diagram 3), short press to is Diagram - 3 complete 1-point calibration and the tester returns to measurement mode. Indication Icon will appear at the bottom left of the LCD screen. 5.5 Rinse the probe in distilled water and dry it. Long press to enter calibration mode. Dip the probe in ph 4.00 buffer solution, stir gently, and allow it to stand still in the buffer solution. When stable icon is displayed on the LCD screen, short press to complete 2-point calibration and the tester returns to measurement mode. Indication icon will appear at the bottom left of the LCD screen. 5.6 If necessary, rinse the probe in distilled water and dry it, and dip the probe in 10.01 buffer solution (sold separately) to complete 3 rd point of calibration according to the steps in 5.5, will appear at the bottom left of the LCD. Notes a) Tester will automatically recognize ph buffer solution. Users can perform one-point, two-point, or three-point calibration. But for the 1 st point calibration, only 7.00 ph solution can be used. Then use other buffer solutions to conduct 2nd or 3rd point calibration. Tester will automatically recognize 5 kinds of ph buffer solutions. Refer to the table below: Calibration USA Series NIST Series 1-point 1) 7.00 ph 1) 6.86 ph 2-point 1) 7.00 ph 2) 4.00 or 1.68 ph 1) 6.86 ph, 2) 4.01 ph or 1.68 ph Calibration Indication Icon Recommended Accuracy and Range Accuracy 0.1 ph Measurement Range<7.00 ph 5

3-point 1) 7.00 ph 2) 10.01 or 12.45 ph 1) 7.00 ph 2) 4.00 or 1.68 ph 3) 10.01 or 12.45 ph 1) 6.86 ph, 2) 9.18 ph or 12.45 ph 1) 6.86pH 2) 4.01 or 1.68pH, 3) 9.18 ph or 12.45 ph Measurement Range>7.00pH Wide Measurement Range b) For ph Calibration buffer solutions, we recommend that users replace new buffer solution after 10 to 15 times of use to keep the standard buffer s accuracy. Do NOT pour the used calibration solutions back into the solution bottles in case of contamination. c) This ph probe will NOT give accurate and stable readings for distilled or deionized water. This is because distilled and deionized water do not have enough ions present for the electrode to function properly. Specialized ph probes need to be used for distilled/deionized water measurement. Contact us at info@aperainst.com for more details. d) When testing purified water like spring water or drinking water, it will take longer for the readings to get stabilized (typically 3-5 minutes) because there is very few ions left to be detected by the sensor in those purified water. e) Do NOT store ph probe in distilled water to prevent permanent damage to the probe. f) For the self-diagnosis information, please refer to the table below: Symbol Self-Diagnosis information Checking and methods to fix Wrong calibration solution or the range of calibration solution exceeds standard. Is pushed before measurement is stable ( comes up and stays) a) Check if calibration solution is correct (1 st point of ph calibration must be ph 7.00) b) Check if electrode is damaged. c) Check if there is any air bubble in the glass bulb ph sensor Wait for the smile icon to come up and stay, then press * If you find any air bubble in the glass bulb of the ph sensor, simply shake the probe for a few times to remove it. The existence of an air bubble in the glass bulb will cause instable measurements. * The 1 st point calibration must be 7.00 ph. Perform the 2 nd point calibration (4.00 ph) immediately after the 1 st point. Do NOT turn off the meter before you conduct 2 nd point calibration. If the meter is turned off after 1 st point calibration, users will need to restart the calibration process with the 7.00 ph first and the 4.00 ph following after. Calibrating directly in ph 4.00 after turning meter off and back on will cause Er1. 6

6.pH Measurement Short press to turn on the tester. Rinse the probe in distilled water and dry it. Dip the probe in sample solution, stir gently, and allow it to stand still in the solution. Get readings after comes up and stays. 7. Conductivity Calibration 7.1 Press key to switch to conductivity measurement mode. Rinse the probe in distilled water and dry it. 7.2 Pour certain amount (about half volume of the calibration bottle) of 1413μS/cm and 12.88 ms/cm conductivity calibration solution into accordant calibration bottles. 7.3 Long press key to enter calibration mode, short press to exit. 7.4 Dip the probe in 1413 μs/cm conductivity calibration solution, stir gently and allow it to stand still in the solution until a stable reading is reached. When stable icon appears and stays on the LCD screen, short press key to complete one-point calibration, the tester returns to measurement mode and indication icon will appear at the bottom left of the LCD screen. 7.5 After calibration, dip the probe in 12.88 ms/cm conductivity calibration solution. If the value is accurate, it is not necessary to conduct 2 nd point calibration. If it is inaccurate, follow the steps in 7.3 to 7.4 to complete the 2 nd point of calibration using 12.88 ms/cm buffer solution. * 1000 µs/cm = 1 ms/cm 8. Conductivity Measurement Press key to turn on the tester. Rinse the probe in distilled water and dry it. Dip the probe in sample solution, stir gently, and allow it to stand still in the solution until a stable reading is reached. Get readings after comes up and stays. Press to switch from Conductivity to TDS, and Salinity Notes a) The TDS and Salinity measurements are converted from the conductivity measurements via a certain conversion factor. b) The tester can calibrate 84μS, 1413 μs/cm and 12.88 ms/cm conductivity calibration solution. User can conduct 1 to 3 points calibration. Refer to the table below. Usually calibrating the tester with 1413 μs/cm conductivity buffer solution alone shall meet the testing requirement. 7

Calibration Indication Icon Calibration Standards Measuring Range 84 μs/cm 0-200 μs/cm 1413 μs/cm 200-2000 μs/cm 12.88 ms/cm 2-20 ms/cm c) The tester has been calibrated before leaving the factory. Generally, users can use the tester directly or users can test conductivity buffer solutions first. If the error is large, then calibration is needed. d) For conductivity calibration solutions, we recommend that users replace new solutions after 5 to 10 times of use to keep the standard solution s accuracy. Do NOT pour the used calibration solutions back into the solution bottles in case of contamination. e) Temperature compensation factor: The default setting of the temp. compensation factor is 2.0%/. User can adjust the factor based on test solution and experimental data in parameter setting P4. Solution Temperature Temperature Solution compensation factor compensation factor NaCl 2.12%/ C 10% Hydrochloric acid 1.32%/ C 5% NaOH 1.72%/ C 5% Sulfuric acid 0.96%/ C Dilute ammonia 1.88%/ C f) 1000 ppm = 1 ppt g) TDS and conductivity is linear related, and its conversion factor is 0.40-1.00. Adjust the factor in parameter setting P5 based on the requirements in different industries. The factory default setting is 0.71. Salinity and conductivity is linear related, and its conversion factor is 0.5. The tester only needs to be calibrated in Conductivity mode, then after calibration of conductivity, the meter can switch from conductivity to TDS or salinity. h) Conversion Example: if conductivity measurement is 1000µS/cm, then the default TDS measurement will be 710 ppm (under the default 0.71 conversion factor), and the salinity be 0.5 ppt. 8

i) For the self-diagnosis information, please refer to the table below: Symbol Self-Diagnosis information How to fix Wrong conductivity buffer solution, which exceeds the recognizable range of the meter. Is pushed before measurement is stable ( comes up and stays) 1. Check if buffer solution is correct 2. Check if electrode is damaged. Wait for the smile icon to come up and then press 9. Parameter Setting 9.1 Setting Chart Symbol Parameter Setting Contents Code Factory Default P1 Select ph buffer standards USA NIST USA P2 Select automatic lock Off On Off P3 Select backlight Off - 1 - On 1 P4 Temperature compensation factor 0.00-4.00% 2.00% P5 TDS factor 0.40-1.00 0.71 P6 Salinity unit ppt - mg/l ppt P7 Select temperature unit C - F F P8 Back to factory default No Yes No 9.2 Parameter Setting When turned off, long press to enter parameter setting short press to switch P1-P2 P8. Short Press, parameter flashes short press to choose parameter, short press to confirm Long press to turn off. 9.3 Parameter Setting Instruction a) Select standard ph buffer solution (P1): There are two options of standard buffer solutions: USA series and NIST series. Refer to following chart: 9

Icons ph Standard Buffer Solution Series USA series NIST series 1.68 ph and 4.00 ph 1.68 ph and 4.01 ph Three-point calibration 7.00 ph 6.86 ph 10.01 ph and 12.45 ph 9.18 ph and 12.45 ph b) Automatic lock (P2): Select On to activate auto lock function. When reading is stable for more than 10 seconds, the tester will lock the value automatically, and HOLD icon will display on LCD. Press key to cancel auto hold. c) Backlight (P3) Off -turn off backlight, On -turn on backlight, 1- backlight will last for 1 minute. d) Factory default setting(p7) Select Yes to recover instrument calibration to theoretical value (ph value in zero potential is 7.00, slope is 100%), parameter setting return to initial value. This function can be used when instrument does not work well in calibration or measurement. Calibrate and measure again after recover the instrument to factory default status. 10. Technical Specifications ph Cond. Range Resolution Accuracy Calibration Points Automatic Temperature Compensation Range Resolution Accuracy -2.00 to 16.00 ph 0.01 ph ±0.01 ph ±1 digit 1 to 3 points 0 50 C (32 122 F) 0 to 200.0 μs, 0 to 2000 μs, 0 to 20.00 ms/cm 0.1/1 μs, 0.01 ms/cm ±1% F.S Calibration Points 1 to 3 points TDS Range 0.1 ppm to 10.00 ppt 10

TDS Factor 0.40 to 1.00 Salinity Range 0 to 10.00 ppt Range 0 to 50 C (32-122 F) Temp. Resolution 0.1 C Accuracy ±0.5 C 11. Icons and Functions 1 Calibration points indication: 2 Stable Measurement: 3 Reading value Auto. Lock: HOLD 4 Self-Diagnostic Information: Er1, Er2 5 Low-Voltage warning: flashes, reminder of battery replacement 6 Three-Color backlight: Blue Measurement Mode; Green Calibration Mode; Red Alarm; 7 Auto. Power off in 8 minutes if no operation. 12. Probe Replacement Screw off the probe ring, unplug the probe, plug in the new replacement probe (pay attention to the probe s position), and screw on the probe ring. The model numbers of replacement probes that are compatible with PC60 are: PC60-E PH60-E (Regular ph glass bulb probe) PH60S-E (Spear ph probe for solids/semi-solids ph testing) PH60F-E (Flat ph probe for surface ph testing) EC60-E (Conductivity probe) 11

13. Warranty We warrant this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS (SIX MONTHS for the probe) from the delivery. This limited warranty does not cover any damages due to: Transportation, storage, improper use, failure to follow the product instructions or to perform any preventive maintenance, modifications, combination or use with any products, materials, processes, systems or other matter not provided or authorized in writing by us, unauthorized repair, normal wear and tear, or external causes such as accidents, abuse, or other actions or events beyond our reasonable control. APERA INSTRUMENTS, LLC Address: 6656 Busch Blvd, Columbus Ohio 43229 Tel: 1-614-285-3080 Email: info@aperainst.com Website: www.aperainst.com 12