ES5 Security Theory/Regulations Answer Schedule

Similar documents
EST Electrical Service Technician Answer Schedule

ES5. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int

IT 28 ELECTRICAL INSPECTOR EXAMINATION ANSWER SCHEDULE. Question 1 Marks Reference Marking notes. (1 mark) ESR 57(3)(e)(ii)

FINAL-ER 42 Electrician Regulations Answer Schedule

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

ELECTRICIAN S THEORY EXAMINATION 11 September 2010 QUESTION AND ANSWER BOOKLET

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 16 September 2017 QUESTION AND ANSWER BOOKLET

ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET

LEP ASSESSMENT REVIEW

ELECTRICIANS REGULATIONS EXAMINATION 29 June 2013 QUESTION AND ANSWER BOOKLET

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 22 November 2014 QUESTION AND ANSWER BOOKLET

ELECTRICIAN S THEORY EXAMINATION 19 June 2010 QUESTION AND ANSWER BOOKLET

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33

INSTALL CIRCUIT PROTECTIVE DEVICES

Electrical Protection

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

Initial and Periodic Inspection and Testing of Electrical Installations ( ) Sample Test

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

FACT SHEET Standard: Electrical Safety

ELECTRICIAN S THEORY EXAMINATION 20 June 2015 QUESTION AND ANSWER BOOKLET

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

The Impact of the 18 th edition (BS 7671:2018)

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)

Element C8.3 Installation, Use and Inspection of Electrical Systems

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

Unified requirements for systems with voltages above 1 kv up to 15 kv

Electricity Safety (Electrical Installations) Regulation 2005

Key elements of the AS3000 Wiring standards and some of the recent changes.

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

SAFETY FACT SHEETS. Electrical Hazards Safety Non Negotiable. G-HS-ST Electrical Hazards. G-HS-FS Version:1

Electrical Workplace Safety

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety.

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 3 NOVEMBER 2009

Fault Finding. Standard/Fundamental Faults

INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT

INDEX Section Page Number Remarks

Electrical Equipment and Terminology

Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals Edition DRAFT

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

BSS Examination Checking Procedures Part 3 - Electrical systems Recommendations for change May 2012

Electric Motor Controls BOMA Pre-Quiz

Ensuring the Safety Of Medical Electronics

Electrical Safety Part II

Chapter 5. Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI)

Electrical Energy and Power Ratings

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Electrical Safety. Introduction

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Effective discrimination of protective devices

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Photovoltaic Solar Plan Review

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

The Management of Electrical Safety in Quarries, Associated Plant and Equipment

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

NZQA registered unit standard version 1 Page 1 of 5

CHAPTER 10 ELECTRICAL. Notes:

SELECT MEMBERSHIP NUMBER Full Installation 75% new and 25% alteration to exsisting

Electrical test equipment for use on low voltage electrical systems

Electrical Safety. Recognizing & Controlling Hazards

"Accredited Test Laboratory" (ATL) means an organisation that is accredited by the South African National Accreditation System (SANAS).

Chapter 14:08 Factories and Works (Electrical) Regulations, Chapter 14:08 Factories and Works (Electrical) Regulations, 1976

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Chapter 9 Basic meters

Fuses still the best form of overload protection

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

SDM72 Start on Demand Modules

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

FAQ S. Main Switchboard Design Criteria. ENGINEERED SOLUTIONS FOR ALL YOUR SWITCHBOARD NEEDS

1.Safe testing IMPORTANT:

Electricity (Safety) Regulations 2010

SubDrive Inline Constant pressure controller Additional information for Australia, NZ TOLL FREE HELP 1300 FRANKLIN

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

OPERATING INSTRUCTION

ELECTRICAL GROUNDING SAFETY PROGRAM

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

Pretest Module 29 High Voltage Unit 1

Electrical Safety Guidelines

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Low Voltage Power Supplies in Electrified Areas

1 THE WOLVERTON SYSTEM OF TRAIN LIGHTING.

Transcription:

ES5 Security Theory/Regulations Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The marker can exercise their discretion and decide on the overall accuracy of any answer that is presented in the candidate s own words. 3. Symbols and terms - alternatives Power W or P Voltage V or E or U Phase Active 4. Key to abbreviated terms: EA Electricity Act 1992 ER Electricity Regulations 1997 AS/NZS Australia and New Zealand Joint Standard NZS New Zealand Standard AS Australian Standard ECP New Zealand Electrical Code of Practice GK General Knowledge Question 1 (a) Any ONE of: The neutral ensures a low impedance fault loop on an earth fault. The lower the resistance of the fault circuit, the higher the fault current and the more reliable the operation of protection equipment (fuses and circuit breakers). Limits the voltage to 230 V to earth. Mass of earth provides an alternative return path for the current if neutral is lost. Limit the potential to earth under fault conditions. It must be connected to the main earthing terminal in the main switchboard (c) (i) Single pole switch shown in the on position. (ii) Double pole switch shown in the off position. ES5 ANSWERS 19 NOVEMBER 2005 1

(d) Disconnect the supply if any circuit fault occurs. (e) A certificate of compliance ES5 ANSWERS 19 NOVEMBER 2005 2

Question 2 (a) When a fault occurs the protective device ( minor device) nearest the fault operates. Before any other protective device ( major device). 60A The maximum current the fuse can continuously carry without overheating the fuse link and causing deterioration. 440V The maximum voltage the fuse can safely withstand across it, without flashover. AC40 This indicates the maximum fault current the fuse can interrupt. (3 marks) (c) (d) When a protective device cannot withstand the prospective short circuit current, it must be backed-up by a device which can. As current through a fuse or circuit breaker increases beyond its current rating, the time taken to operate decreases. (e) ES5 ANSWERS 19 NOVEMBER 2005 3

Question 3 (a) (i) The maximum current that a fuse-link will carry continuously without deterioration or operating. OR The maximum level of protection for the circuit (ii) Current rating = Fusing Current Utilisation Category (fusing factor) = 67.5 1.5 = 45 A Any TWO of: If correctly threaded, prevents fuse element from bulging out the side of the carrier and being accessible to touch. or If incorrectly threaded, contact could be made with the fuse element. If correctly threaded, under overload conditions the heat produced in the element is confined to the tunnel area. or If incorrectly threaded, the arc or molten metal may escape under overload conditions. If correctly threaded, under fault conditions the arc and molten element is confined within the fuse carrier and base. or If incorrectly threaded, the arc or molten metal may escape under fault conditions. If correctly threaded, the fuse wire is sheltered in the tunnel and well clear of the terminals which act as a heat sink. Or If incorrectly threaded, will be slow to respond to overload fault. ES5 ANSWERS 19 NOVEMBER 2005 4

(c) Any THREE of: If the fuse blows again an arc may be established between the fuse terminals causing damage or injury Cannot safely interrupt short circuit currents of much higher values. Fuse wire may protrude past the holder which creates an exposure to shock. Suitable fixing for the fuse wire is not generally available. Fuse holder is not fire proof. Slower operation/acting. Alters protection characteristics changes Utilisation category (3 marks) (d) Any TWO of: It will safely interrupt short circuit currents of much higher values or higher rupturing capacity. It eliminates arcing because the fuse element is sealed. It is obtainable in a range of Utilisation category (fusing factors). Current rating is clearly marked. Reliable operation within prescribed limits. Good discrimination. Constant fusing characteristics. Faster operation/acting. Doesn t deteriorate over time. ES5 ANSWERS 19 NOVEMBER 2005 5

Question 4 (a) (i) To shunt excess current away from the load. (ii) A Zener diode is designed to carry significant reverse current but a normal rectifier diode cannot. \ (iii) The resistance limits the current through the Zener diode. Any TWO: To the maximum value capable of being handled by the diode without damage. In the event of the load becoming disconnected or open circuited Inductor Capacitor Resistor (c) Any TWO: Current drops to zero Current drops to less than holding current Remove anode to cathode voltage. Apply reverse polarity voltage across the SCR. ES5 ANSWERS 19 NOVEMBER 2005 6

Question 5 (a) Imbalance between the phase and neutral currents. A magnetic field is induced into the iron core. The induced magnetic field induces a current in the sensing coil The tripping coil is energised, isolating the circuit (c) (d) 30 milliamps Because the RCD limits the time a current can flow through a body. The RCCB does not provide overcurrent or short-circuit protection. (e) Yes The PRCD will not reliven when supply is restored. or The device must be reset before use. ES5 ANSWERS 19 NOVEMBER 2005 7

Question 6 (a) (i) Effectively connected to the general mass of Earth (ii) In relation to fittings or electrical appliances, means that the fittings or appliances are deliberately disconnected from any source of electricity. ER2 (i) 5% of 230 volts = 11.5 volts (ii) 5% of 400 volts = 20 volts ER 53(3) (c) Any TWO of: Final subcircuits that supply: Socket-outlets having rated currents not exceeding 63A Hand-held Class I equipment Portable equipment intended for manual movement during use. AS/NZS 3000: 1.7.4.3.4(a) (d) Circuits including submains and final subcircuits supplying fixed or stationary equipment. AS/NZS 3000: 1.7.4.3.4 (e) Red or Any colour except Black, Light Blue, Green or Green/Yellow. AS/NZS 3000: Table 3.5.1 ES5 ANSWERS 19 NOVEMBER 2005 8

Question 7 (a) Insulation, in accordance with Clause 1.7.3.3. Barriers or enclosures, in accordance with Clause 1.7.3.4. Obstacles, in accordance with Clause 1.7.3.5. Placing out of reach, in accordance with Clause 1.7.3.6. AS/NZS 3000: 1.7.3.2 (4 marks) Any TWO of: IPXXB IP2X. IP4X for horizontal top surfaces that are readily accessible. (c) The use of a key or tool An interlocking device is fitted An intermediate barrier is provided AS/NZS 3000: 1.7.3.4.1 (2 mark) AS/NZS 3000: 1.7.3.4.3 (3 marks) (d) Two ES5 ANSWERS 19 NOVEMBER 2005 9

Question 8 (a) AS: /NZS 3760 Type of test (i) Type of instrument required Earthing Ohmmeter or other continuity instrument with a low reading ohms scale (ii) Test result Max 1 ohm resistance Insulation resistance test Insulation resistance tester min 1 Mohm AS/NZS 3760: Table 2 (c) Any FIVE of from AS/NZS 3760:2001: Check for obvious damage or defects in the accessories, connectors, or plugs. Check that flexible cords are effectively anchored to equipment and plugs. Check that the inner cores of flexible supply cords are not exposed or twisted; Check that the external sheaths are not cut, abraded, twisted, or damaged to such an extent that the insulation of the inner cores is visible Check that unprotected conductors or insulation tape are not in evidence. Check that any controls are in good working order i.e. they are secure, aligned and appropriately identified. Check that covers, guards and the like are secured in the manner intended by the manufacturer or supplier. Check that safety facilities and devices are in good working order. AS/NZS 3760: 2.3.2 (5 marks) ES5 ANSWERS 19 NOVEMBER 2005 10

Or Any FIVE of from AS/NZS 3760:2003: Check for obvious damage or defects in the accessories, connectors or plugs and for discolouration that may indicate exposure to heat, chemicals and moisture. Check that flexible cords are effectively anchored to equipment and plugs. Check that the inner cores of flexible supply cords are not exposed or twisted; Check that the external sheaths are not cut, abraded, twisted, or damaged to such an extent that the insulation of the inner cores is visible Check that unprotected conductors or banding insulation tape are not in evidence. Check that any operating controls are in good working order i.e. they are secure, aligned and appropriately identified. Check that covers, guards and the like are secured in the manner intended by the manufacturer or supplier. AS/NZS 3760: 2.3.2 ES5 ANSWERS 19 NOVEMBER 2005 11

Question 9 (a) Lodge a written complaint with the Registrar Any TWO of: * Cancellation of the registration * suspension of the registration * limited to such work as the Board may specify * limited to work only on approved premises * limited to work only in the employ of an approved employer * impose a fine EA 119 EA 127(2) (c) (i) Practising licence EA 95 (ii) (iii) The Registrar When the holder ceases to be registered. EA 96(1) EA 138 (c) That consists of or includes loss of consciousness or That necessitates the person suffering the injury (i) Being admitted to hospital (ii) Receiving medical treatment from a health care professional EA 16(2)(a) ES5 ANSWERS 19 NOVEMBER 2005 12

Question 10 (a) Any FOUR of: Continuity of the earthing system Insulation resistance Polarity Correct circuit connects Operation of RCDs AS/NZS 3000: 6.3.3.1 Any TWO of: To ensure that the insulation resistance between all live conductors and earth is adequate. To ensure that the insulation resistance between all live parts and earth is adequate. Prevent electrical shock hazard from inadvertent contact. To prevent fire hazards from short circuits. To prevent equipment damage. AS/NZS 3000: 6.3.3.3.1 (c) 500 V d.c. AS/NZS 3000: 6.3.3.3.1 (d) (e) Maintain its terminal voltage with +20%, -10% of the nominal open circuit terminal voltage. When measuring a resistance of 1 MΩ on the 500 V d.c. range or 10 MΩ on the 1000 V d.c. range. AS/NZS 3000: 6.3.3.3.1 Any ONE of: To ensure protective earthing conductors do not normally carry current. AS/NZS 3000: 6.3.3.5(a) To ensure no short circuit exists, because a short-circuit current flowing between live conductors and through part of the earthing system can cause considerable fire damage or personal injury, particularly in high current locations. AS/NZS 3000: 6.3.3.5 ES5 ANSWERS 19 NOVEMBER 2005 13

To prevent the transposition of active and neutral conductors of the consumers mains or submains (with MEN connection at outbuilding or detached portion) resulting in the electrical installation earthing system becoming energized; and AS/NZS 3000: 6.3.3.4.1(a) To prevent combinations of incorrect active, neutral and earthing conductor connections resulting in the exposed conductive parts of the electrical installation becoming energized; and AS/NZS 3000: 6.3.3.4.1 To prevent the connection of switches in neutral conductors, resulting in parts of appliances, such as heating elements and lampholders, remaining energized when the switches are in the OFF position. AS/NZS 3000: 6.3.3.4.1(c) (f) To ensure that the earthing systems has been installed in a manner that will cause circuit protective devices to operate if there is a fault between live parts, other than the neutral, and the mass of earth. Will ensure that electrical equipment parts that are earthed do not reach dangerous voltages when earth faults occur. AS/NZS 3000 6.3.3.2.1 ES5 ANSWERS 19 NOVEMBER 2005 14