KTM Hindle Series 300 Ultra-Seal two piece metal seated ball valves Installation and Maintenance Instructions

Similar documents
KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS

Fisher 2052 Diaphragm Rotary Actuator

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

KEYSTONE FIGURE 79 PNEUMATIC ACTUATOR OPERATING AND MAINTENANCE INSTRUCTIONS

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

Fisher 3024C Diaphragm Actuator

Fisher Z500 Severe Service Ball Valves

Installation, Operation and Maintenance Instructions Series 608 Ball Valve

KEYSTONE SERIES GR RESILIENT SEATED BUTTERFLY VALVES GRW/GRL INSTALLATION AND OPERATION MANUAL

NEOTECHA NEOSEAL BUTTERFLY VALVE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Butterfly valves Figure 56 Installation & Maintenance Instructions

Fisher RSS Lined Globe Valve

Fisher 656 Diaphragm Actuator

PRESSURE/TEMPERATURE RATINGS ASME B16.34 VALVES

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Fisher D2T FloPro Control Valve

Fisher RSS Lined Globe Valve

Fisher V250 Ball Valve

METERING VALVE 2" STEM GUIDED

Fisher ENVIRO SEAL Packing System for Rotary Valves

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Fisher TBX Hydro Plug Fixture

HANCOCK 600 GATE, GLOBE AND CHECK VALVES FORGED STEEL

Keystone Figure 85/86 Check valves Installation and Maintenance Instructions

2-SEATS (L-PORT) AND 4-SEATS (L AND T-PORT)

Sempell High Pressure Stop Valves Model VA500 (DIN)

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

Fisher 1077 Manual Handwheel Rotary Actuator

Fisher CVX Hydro Plug Fixture

Baumann Way Control Valve

Fisherr V150S Slurry Vee-Ball Control Valve NPS 3 through 12

V-SEGMENT SERIES V-Port Segment Control Valves (VS/VV/VM) Installation & Maintenance Manual

Fisher A31D Double-Flange High-Performance Butterfly Valve

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance.

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

Fisher 644 and 645 Differential Pressure Pump Governors

Val-Matic QuadroSphere Trunnion Mounted Ball Valve

HIGH PRESSURE CONTROL VALVE R2L ACTUATOR

M Series Manual Handwheel Gear Actuator

Fisher 685 Piston Actuator

Baumann Sanitary Angle Control Valve

Types C401, C402, C407, C421, C427, C403, and C831 Jet Bleed Internal Valve Retrofit Kits

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher Vee-Ball V150 and V300 NPS 14 through 24x20 Rotary Control Valves

KTM V-PORT CONTROL BALL VALVE FULL BORE AND REDUCED BORE

Fisher A31A Cryogenic High Performance Butterfly Valve

Fisher DSV High Performance Digester Switching Valve

TBV OPERATION AND MAINTENANCE MANUAL SERIES 1800: FLANGED BALL VALVE. For technical questions, please contact the following:

Fisher 9500 Butterfly Control Valve

Baumann Little Scotty Bronze Control Valve

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE

Fisher 1B and 1BR Constant Pressure Pump Governor Actuators

Baumann 24000F Wafer Control Valve

Fisher D4 Control Valve Assembly

Baumann Mikroseal Control Valve

Fisher SS-263 Volume Booster

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15

Type 644 and 645 Differential Pressure Pump Governors

INSTALLATION - MAINTENANCE MANUAL Severe Service Series M4 Ball Valve

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

Baumann Sanitary Control Valve

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Guide

KEYSTONE SERIES GRF RESILIENT SEATED BUTTERFLY VALVES INSTALLATION AND OPERATION MANUAL

Baumann Sanitary Diaphragm Angle and Inline Control Valve

Features. Product Bulletin 51.6:8590 August Valve D104017X012

Errata Sheet. for. SS-260 Valve

Fisher 377 Trip Valve

Installation, Operation, and Maintenance Manual

M Series Manual Handwheel Gear Actuator

Yarway Que - Temp Desuperheater Standard-/heavy Duty Installation and maintenance Instructions

Fisher V250 Rotary Control Valve

Fisher V150S Slurry Vee-Ball Control Valve

Anderson Greenwood Single Active SSV Installation and Maintenance Instructions

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

KEYSTONE. Check valves Figure 85/86 Installation & Maintenance Instructions. Figure 85. Figure 86.

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

USER INSTRUCTIONS. Valtek Valdisk TX3 Triple Offset Butterfly Control Valve. Installation Operation Maintenance. Experience In Motion

Fisher 377 Trip Valve

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

Fisher 8590 High-Performance Butterfly Valve

Fisher POSI-SEAL A31A Cryogenic High Performance Butterfly Valve

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

26 Series Stainless Steel 2-way Ball Valves

Before installation these instructions must be fully read and understood

Type 1051 and 1052 Diaphragm Rotary Actuators

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

SEries 41 check valve installation, operation & maintenance manual

Fisher Vee-Ball V150 and V300 NPS 14 through 20 Rotary Control Valves

Fisher V270 Full-Bore Ball Control Valve

DVG/AF Variable Geometry Desuperheater

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

Design V150S Slurry Vee-Ball Control Valve

Gachot Ball Valve Type V16 carbon steel / reduced bore / DN 8 to DN 200

Baumann Pneumatic Actuators

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Transcription:

Before installation these instructions must be fully read and understood Warning For safety reasons, it is important to take the following precautions before you start work on the valve: 1. Personnel making any adjustments to the valves should utilize equipment and clothing normally used to work with the process where the valve is installed. 2. The line must be depressurized, drained and vented before installing the valve. 3. Handling and installation of all valves, operators and actuators must be carried out by personnel trained in all aspects of installation and manual/mechanical handling techniques. 4. Ensure the valve pressure/temperature limitations marked on the identification label are above or equal to service conditions. 1 Storage / protection / selection Storage When valves are to be stored for some time before being fitted, storage should be in the original delivery crates with any waterproof lining and/or desiccant remaining in place. Storage should be off the ground in a clean, dry, indoor area. If storage is for a period exceeding six months the desiccant bags (if supplied) should be changed at this interval. Protection KTM Hindle valves are delivered with protection according to customer s specification, or in accordance with the Quality Assurance Manual, to protect the valve seats and closure member from damage. Wrapping and/or covers should be left in place until immediately before fitting to the pipe. Selection Ensure the valve s materials of construction and pressure/temperature limits shown on the identification plate are suitable for the process fluid and conditions. If in doubt contact KTM Hindle. 2 Installation 1. KTM Hindle Series 300 valves are bi-directional as standard and may be fitted in either direction. 2. Installation may be carried out with stem displaced through any angle permitted by the bolting. 3. Remove protective covers from valve faces. 4. Ensure that mating flanges and gaskets are clean and undamaged. 5. Should there be any possibility of abrasive particles (weld slag, sand etc.) within the piping system, this could damage valve seating/ball. The system will need to be flushed clean. 6. Ensure mating pipe flanges are aligned correctly. Bolting should be easily inserted through mating flange holes. 7. Fit the valve into pipework ensuring easy access of the lever/handwheel. 8. Tighten the flange bolts in a diagonal pattern. 3 Operation and routine maintenance!! Read all warning labels fitted to the valve before operation or maintenance!! Scope KTM Hindle Series 300 valves both manual and actuated. For special service designs, typically cryogenic see separate instructions. Operation All standard manually operated valves are clockwise to close. The closed position is indicated by either the handlever or indicator arrow being at 90 to the pipe/valve bore axis. Routine maintenance No routine maintenance is required other than periodic inspection to ensure satisfactory operation and sealing. Any sign of leakage from the gland packing should be addressed immediately by depressurizing the valve and tightening the gland nut. If no further adjustment is possible, or if seat or joint leakage is suspected, the valve will require a complete overhaul. This should be carried out after depressurisation and in accordance with KTM Hindle Maintenance Instructions. Only KTM Hindle spares should be used. Spare parts KTM Hindle valves are identified by a figure number, which is stamped on the identification plate, located on the valve body flange. This reference should be quoted in respect of any after sales queries, spare parts or repair enquiries/orders. Emerson.com/FinalControl 2017 Emerson. All Rights Reserved. VCIOM-02387-EN 18/03

Caution Before attempting any maintenance, ensure the system has been fully depressurized and if necessary drained of any dangerous fluids. The valve being removed should be operated at least once and left in half open position before removal. Before disassembling the valve, ensure the valve has been decontaminated correctly from any harmful gasses or fluids and that it is within a safe temperature range for handling. Personnel making any adjustments to the valves should utilize equipment and clothing normally used to work with the process where the valve is installed. Handling of all valves, operators and actuators must be carried out by personnel trained in all aspects of manual and mechanical handling techniques. 4 Maintenance Parts identification The illustrations in Section 5 show the parts comprising the Series 300 valves. 4.1 Replacement of valve components If no further adjustment of the gland is possible and stem leakage is still evident or seat leakage is suspected, the valve will need to be removed from the line in order for new seats/ seals to be fitted. After removal of the valve, place the valve on a workbench and adopt the following procedure to remove/replace the seats/seals. 1. Remove connector bolting, and then connector. 2. Remove ball. 3. Remove bottom seat ring and and bottom seat graphite seal. 4. Remove the upper seat from the connector housing. 5. Remove the Wavo spring graphite seal and energizer ring. 6. Remove the operator (lever, gearbox, actuator) in accordance with instructions in Section 4.2. 7. Remove gland nut, tab washer, Belleville washers and gland ring. 8. Remove stem and thrust seal. 9. Remove graphite fire-seals. Refitting is the reversal of removal. Before refitting, ensure all sealing and metallic surfaces in seat pockets and stem seal bores are free from damage/corrosion. Minor defects can be polished using abrasive cloth. If major defects are found contact KTM Hindle s service department for possible repair or component exchange. 4.2 Removal and refitting of operator Removal of handlever/ T -bar 1. Remove the lever nut/screw and lever washer. 2. Remove the handlever/ T -bar. Removal of gearbox/actuator 1. Remove mounting bracket screws. 2. Remove mounting bracket and gearbox/actuator. 3. Remove drive adaptor. Refitting is the reversal of removal. 4.3 Setting of travel stops on gearbox and actuated operators (See Fig.3 Section 5 for diagram of travel stop positions) With valve out of pipeline 1. Close valve fully 2. Remove plastic indicator cover from top of gearbox 3. Release closed stop screw. 4. Align diamond shaped drive points parallel to valve bore as shown in Fig.3 (Section 5). 5. Tighten closed stop screw, allowing for backlash between adaptor and stem. 6. Hold stop screw in position with Allen key and tighten locking nut. 7. Open valve fully. 8. Visibly check that ball port is aligned with valve bore. If incorrect follow rest of procedure. 9. Release open stop screw. 10. Adjust ball position using handwheel until valve is porting correctly. 11. Tighten open stop screw and lock off with locknut. With valve in pipeline Adopt steps 1-6 as above for open and closed positions. NOTE For the setting of stops on actuators, see separate instructions. Orientation of gearbox 1. As standard, gearbox input shaft is across line with the offset opposite the valve body connector end. 2. Orientation of input shaft can be rotated through 180 if required. This requires removal of gearbox screws, rotation of gearbox through 180, and refitting of gearbox screws. 2

4.4 Actuator assembly Prior to assembly, check the following details 1. Actuator type and style, i.e. double acting or spring return. 2. Position of actuator in relation to valve and pipeline. 3. Fail-safe position of valve, i.e. open or closed. Assembly 1. Close valve fully. 2. Remove handlever nut. 3. Remove handlever. 4. Remove stop screws and stop collars. 5. Ensure that adaptor coupling is a good fit with actuator drive and valve stem. 6. Position mounting bracket on to valve and fit bracket screws. Do not tighten. 7. Position adaptor coupling on to valve. 8. Assemble actuator over adaptor coupling and on to mounting bracket. 9. Fit actuator screws. Do not tighten. 10. With actuator secure, check for free alignment of adaptor coupling between actuator drive and valve stem. Tighten mounting bracket screws and re-check alignment. 11. With actuator in correct position, tighten actuator screws. 12. If the actuator is fitted with travel stops, adjust to the closed position. Operate to the open position and adjust so that the ball port is aligned with the valve bore. Figure 1 Valve and actuator diagram 3

5 Component and assembly drawings Figure 2 Component assembly drawing Parts list Item Component 1 Body 2 Connector 7 Ball 8 Shaft 21 Gland collar 22 Shaft anti-static ball 23 Shaft anti-static spring 24 Body seat 25 Connector seat 26 Seat energizer 27 Seat spring 29 Gland spring 30 Shaft nut 31 Tab washer 50 Body studbolt 51 Body nut 60 Body primary seal 65 Shaft primary seal 75 Shaft fire seal 76 Body seat seal 77 Connector seat seal 90 Handlever 91 Handlever washer 92 Handlever screw 93 Stop screw 94 Stop collar 96 Gearbox 97 Mounting bracket 98 Gearbox screw 99 Bracket screw 100 Coupling 102 Handwheel 104 T-Bar adaptor 105 T-Bar tube 106 T-Bar washer 107 T-Bar screw Gearbox - Showing travel stop setting screws 1. Indicates closed position stop. 2. Indicates open position stop. Figure 3 Gearbox diagram Align diamond drive with valve bore center line - as indicated 4

Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. KTM is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson.com/FinalControl 5