ABS lifting station Synconta

Similar documents
Lifting Station Type ABS Synconta 900B

IP 900 W/KS & IP 900 D/KS

The Pump Matic Range

Instruction Manual. Sewage lifting station compli 300

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet

INSTALLATION GUIDELINES

Septic Tank. Installation Guidelines

Poly-sump PKS-B 800 for submersible sewage pumps With plastic valves and guide rail. Application. Description

JUNG PUMPEN BAUFIX 200. Instruction Manual

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines

Series description: Wilo-DrainLift KH 32

Products for sewage systems

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

JUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS

JUNG PUMPEN compli 100 MC Sewage lifting stations

CATALOGUE SEWAGE MANHOLES

Separators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation

GRUNDFOS DATA BOOKLET AP, KP. Wastwater pumps 50 Hz

JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS

ABS submersible sewage pump AFP

Gullies. Box - Gutters. Slot - Gutters. Grease Locks

Sewage transport Submersible pumps

GB-250. Submittal Specifications Installation Application Specific Details

SIR INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz. operating limits. Useful volume up to : S.I.R. 2500

HOMA Product Range. Electric Submersible Sewage Pumps Ranges K, KX. The source for world wide pump technology. Discharge Size DN 200 up to DN 400

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

RAINWATER HARVESTING SYSTEMS

Installation and Operating Instructions

PRE-PLUMBED SEWAGE SYSTEM

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

GRAF EcoBloc Stormwater Management System

GAMMA Septic Tanks Installation & Operation Guidelines

OWNERS MANUAL ECODIVER

original operating manual Operating manual Translation of the Item-No.: ,

KESSEL-Staufix double flap lockable backwater valve KESSEL-Staufix single flap lockable backwater valve KESSEL- Staufix single flap backwater valve

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

A408 GB. Pneumatic oil and diesel pumps 1:1

WSB clean: Installation Manual

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

Submersible Effluent Pump

GRAF EcoBloc Stormwater Management System

Separators. industrieblick Fotolia.com. For indoor or below ground installation ACO Light Oil Separators Coalisator-P

Installation & Operating Manual

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

JUNG PUMPEN MULTICUT SEWAGE PUMPS

ELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS. Ranges MX, V, K Discharge Size DN 80 - DN 150

10 mm free passage. Submersible drainage pumps US Application. Safe to run dry. Easy to maintain with guide rail system. 10 mm free passage

Automatic concealed bollards 275 H600 and 275 H800 with pit

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Flow booster type ABS SB 900 to 2500

ESE Series Cast Iron Sewage Pumps

The school consists of technical articles, intended to help pump users with common matters in pumping with submersible pumps.

PRODUCT DATA. Parking Automat P kg 1

HAWLE-AIR RELEASE VALVES

Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance.

SUBMERSIBLE WATER PUMP

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidHook Control Gate Valve

Operating manual Separator

Aqualift F XL Lifting Stations

Fight F.O.G. with AMA-GREASE Separator System Solutions

Cable-Tight Wire Management System

Installation Manual. Q Series Quadplex Grinder Systems. Contents

General Information Hydrants and Flushing Valves

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

INSTALLATION MANUAL (cod )

SEPTIC TANKS. Round septic tanks. Standard version ECO version. Rectangular septic tanks. ECO version

Vacuum Sewer Systems Construction Manual

Separators. The new rotomoulded tank system ACO Grease, starch and light liquid separators for below ground installation

Functional Description and Specifications. Intended Use. Packing List

Package Pump Stations

JUNG PUMPEN US SUBMERSIBLE DRAINAGE PUMPS

Operating & Maintenance Manual Compact Domestic Booster Set Model BTAF Arrow Valves

HYDROCARBON SEPARATORS

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

Installation and maintenance instructions for the GRAF Universal External and internal Filter 3

MODEL H INSTALLATION INSTRUCTIONS

Operating & Maintenance Manual Break Tank & Pump Set Model BTAB Arrow Valves

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

RAINWATER HARVESTING INSTALLATION GUIDE RH High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application

Fuel and Oil Separators

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

Technical Bulletin. Terrain FUZE HDPE Thermal Expansion L = L T. Bulletin P1

Grey Water and Condensate Pump. Rotex. Type Series Booklet

Voltmaster Centrifugal Trash Pumps

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

ÖWAMAT. National technical approval Z Deutsches Institut für Bautechnik, Berlin

PROJ. NO SECTION HYDRONIC PUMPS

Technical Bulletin. Terrain FUZE HDPE Thermal Expansion L = L T. Bulletin P1

HORIZONTAL SPLIT CASING PUMP

SB UNDERGROUND AIR VALVE ASSEMBLY INTRODUCTION FEATURES INSTALLATION

CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638

Unilift KP 150, KP 250, KP 350

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Operation Manual Woltman. Operation Manual WOLTMAN Water Meters

Flygt TOP 65, 100 and 150. Turnkey pump stations

Assembly instructions

Transcription:

15975187GB (03/2006) 106800 GB Installation and Operating Instructions www.absgroup.com

Installation and Operating Instructions 601 801 901 901L 902 902L Contents 1 General... 3 1.1 Application areas... 3 1.2 Layout of the Synconta tank and installation example as single pumping station in accordance with EN 12056 for drainage of buildings and sites... 3 1.3 ABS high level coupling with discharge pipe pump suspension. (Synconta 901902 only)... 5 1.4 Commentary on the legal DIN EN regulations covering the use of lifting stations for the pumping of effluent containing faecal matter... 5 1.5 Description... 5 2 Safety... 6 3 Transport... 6 4 Setup and Installation... 6 4.1 Installation of the collection tank... 6 4.2 Opening of the collection tank inlet ports... 6 4.3 Filling in of the pit... 7 4.4 Discharge Line... 7 4.5 Level control (Synconta 901 and 902 only)... 8 4.6 Installation of the control unit... 8 5 Commissioning... 8 6 Maintenance... 9 6.1 Commentary on maintenance of lifting stations in accordance with EN 12056... 9 6.2 General maintenance hints... 9 ABS reserves the right to alter specifications due to technical developments

Installation and Operating Instructions 3 1 General 1.1 Application areas Syntheticprefabricated, corrosion resistant sump for ABS submersible pumps designed as single pumping station for automatic pumping of wastewater and sewage in accordance with DIN/EN 12056 from locations and areas below the backwash level. m These lifting stations may not be used for the collection or pumping of flammable or corrosive liquids. Effluent containing grease, petrol, or oil should only be brought to the lifting station via a separation device. 1.2 Layout of the Synconta tank and installation example as single pumping station in accordance with EN 12056 for drainage of buildings and sites. 106900 Legend Figure 1 Installation example 1 ABS submersible pump 2 ABS coupling above water level, self sealing 3 Ball check valve 4 Ball shutoff valve 5 Measuring device (submerged tube) for pneumatic level control 6 Pressure line 7 Four inlet pipes DN 150 8 Vent/cable pipe DN 100, lead to above roof level 9 Cable duct 10 ABS control unit, can be chosen with cabinet The regulations of DIN 1986/100 EN 12050 and 12056 should be observed!

4 Installation and Operating Instructions 107000 Figure 2 Installation example shows version with manhole cover suitable for light vehicular traffic. Legend 1 ABS submersible pump 6 Discharge line 2 Synthetic collection tank 7 Cable duct 3 Three DN 150 inlet ports, one DN 100 inlet port 8 Vent/cable pipe DN 100, lead to above roof level 4 Ball shutoff valve 9 Control unit 5 Ball check valve 10 Backwash level Legend 1 ABS Submersible pump 2 Synthetic collection tank 3 Two DN150/DN100 inlet ports 4 Ball shut off valve 5 Discharge line 6 Vent/Cable pipe DN70 7 Backwash level 111500 Figure 3 Installation of Synconta 601 above ground version

Installation and Operating Instructions 5 1.3 ABS high level coupling with discharge pipe pump suspension. (Synconta 901902 only) Legend The ABS high level coupling ensures a quick and easy installation. The special connection unit with coupling piece is installed and secured in the sump together with the valves before the sump itself is installed. The complete pump unit is lowered with a chain by hand down the guide tube. The unit automatically aligns and locates itself in the correct position, effecting a seal on the ABS high level discharge coupling, without the need to enter the sump. This automatic coupling process is especially useful where checking or inspection work is needed. The pump unit can be lifted out and lowered down even if the sump is flooded A B C D E F Bracket fixed installation Guide tube Bracket with guide claws Chain to withdraw and lower pump for inspection Balltype nonreturn valve Shutoff valve G Discharge line connection G 2 H J Flushing connection Pneumatic level control Figure 4 ABS high level coupling with discharge pipe pump suspension 1.4 Commentary on the legal DIN EN regulations covering the use of lifting stations for the pumping of effluent containing faecal matter. Automatically operated lifting stations are prescribed if: the water level in the odour lock of the effluent source lies below the sewer backwash level. rainwater gullies are present where the upper edge of the inlet grid lies below the sewer backwash level. The sewer backwash level is the maximum possible water level in the public sewer network. Information on this can be obtained from your local authority. If the backwash level has not been fixed by the local authority, then the surface level of the roadway at the connection point is taken to be the level. The regulations also require that all wastewater which can cause offensive odours must be collected in closed, odourtight, and freestanding collection tanks. The collection tanks must be vented by vent pipes which are brought above roof level. 1.5 Description The fully equipped prefabricated synthetic Synconta tank can be used where a medium amount or steady flow of waste water is present. The Synconta is intended for waste water disposal in buildings, which are built below the backflow and cannot depend on the natural gradient to allow the waste water to flow directly into the sewage system. The tank is installed outside the building on open ground and is an effective, quick and economical solution to the sewage problems of the contractor and architect. Suitable for vehicular traffic if used with appropriate lid. The Synconta 901 is suitable for installations according to DIN EN 124 Group 1 permissible traffic tonnage 5 kn/m2. Maximum permissible outside pressure 0.4 bar. 107100

6 Installation and Operating Instructions 2 Safety The general and specific health and safety hints are described in detail in the separate booklet Safety Hints. If anything is not clear or you have any questions as to safety make certain to contact the manufacturer ABS. 3 Transport m During transport the unit should not be dropped or thrown. 4 Setup and Installation 4.1 Installation of the collection tank The inlet lines must be laid in such a manner that there is a continuous fall of the prescribed magnitude to the inlet ports of the collection tank. The regulations for underground engineering work should be observed. The pit must be approximately 30 cm deeper than the unit and care taken that no soil can slide back in. The pit is to be filled with sand (grain size up to 2 mm) up to the point where the unit is installed. The unit is secured against floating up, up to a water table of 0,5 m above the tank floor. If the water table is higher, additional protection against floating up is necessary. This can achieved by setting the bottom area of the tank in concrete. (see Fig. 5) Lower the unit into the pit and align on the prepared foundation. The foundation must be free of stone or other large objects. Additional filling may be required. Fill the pit with sand to the upper edge of the tank bottom. Put on tank cover, connect inlet ports and discharge lines. 4.2 Opening of the collection tank inlet ports Only open inlet ports that are to be used. Only saw off as little as possible so that as much neck as possible is left for the plug connection. (Note the notch on the port neck). File down sharp edge inside and outside.

Installation and Operating Instructions 4.3 Filling in of the pit The filling material should be filling sand or sand from a gravel pit maximum particle size is 32 mm. Marly soil, rubble, stones or sharp particles should not be used. Care should be taken that the pit is filled in evenly from all side in order to avoid pushing in the side of the tank. The material should be filled in layers of maximum 30 cm. The individual layers should be evenly compacted using a hand rammer. Do not use a mechanical compactor. If the surrounding area is a marl soil or the water table is high the unit should be should be secured in position with sand or concrete in order to stop it from floating up. The concrete should only be used for securing the base section of the tank. Any device for lowering the water table should only be switched off after the pit has been filled and compacted. Do not use more than one extension. The maximum allowable depth is 2200 mm. Do not compress the filling sand with a vibrator plate. A minimum gap of 100* mm must be maintained between the extension sleeve and the top of the tank. This is required to prevent surface loading through the tank. (Synconta 801 only) Legend 1 Tank cover with support ring 2 Extension sleeve* 3 Tank 4 Pit 5 Discharge line 6 Inlet port 7 Inflow line 8 Floatation protection 9 Filling sand 10 Anchor bolts (Synconta 801 only) 11 Discharge cap 107200 Figure 5 Synconta tank installation 4.4 Discharge Line The discharge line must be installed in compliance with the relevant regulations. DIN 1986/100 and EN 12056 applies in particular to the following: The discharge line should be fitted with a backwash loop (180 bend) located above the backwash level and should then flow by gravity into the collection line or sewer. The discharge line should not be connected to a down pipe. No other inflows or discharge lines should be connected to this discharge line. Where provided the discharge cap must be fitted between the coupling and the tank. The discharge line should be installed so that it is not affected by frost. The vent line is connected by means of a pushon sleeve to the vertical outlet at the top of the collection tank. It should be of constant crosssection (min. DN 70) and should have a continuous rise to above roof level.

8 Installation and Operating Instructions 4.5 Level control (Synconta 901 and 902 only) The level control is a pneumatic device with a submerged tube for measuring and control line. (Plastic tube to control panel). The measuring vessel is built into the Synconta tank, the required switch and control units are mounted outside in the control unit. When apply a static level control (without compressor or aeration) the height of the submerged tube for measuring should be adjusted, so that it is 20 cm above the middle of the volute of the pump. The run on time, set at 30 seconds when delivered, is to be set so that the submerge tube measuring is empty when the pump is switched off. 4.6 Installation of the control unit The control unit should be fitted above possible flood level in a well ventilated room and in an easily accessible position. Protection Class of the control unit IP 54. The control unit should be secured at all fixing points. The fixing holes are accessible after unscrewing the lower housing cover. Do not drill through the housing of the control unit itself. The mounting location of the control unit should be chosen in such a manner that the control line rises in a continuous manner to the control unit. The control line must not be kinked. A number of different control box models exist. Please check the wiring diagram/ instruction manual in the control box. 5 Commissioning m The safety hints in the previous sections must be observed! Before commissioning the unit should be checked and a functional test carried out. Particular attention should be paid to the following: Have the electrical connections been carried out in accordance with regulations? Have the thermal sensors been connected? Is the seal monitoring device (where fitted) correctly installed? Is the motor overload switch correctly set? Have the power and control circuit cables been correctly fitted? Was the sump cleaned out? Have the inflow and outflows of the pump station been cleaned and checked? Is the direction of rotation correct even if run via an emergency generator? Are the level controls functioning correctly? Are the required gates valves (where fitted) open? Do the nonreturn valves (where fitted) function easily? Have the hydraulics been vented in the case of dry installed pumps?

Installation and Operating Instructions 9 6 Maintenance c Before Before commissioning the collection tank should be cleaned of any large particles and filled with water. If the control line (rubber hose) was connected to the retaining pipe after the collection tank was fitted the collection tank has to be emptied manually once by setting the selector switch Hand. After commissioning the lifting unit is normally operated with the selector switch in position Auto. commencing any maintenance work the unit should be completely disconnected from the mains by a qualified person and care should be taken that it cannot be inadvertently switched back on. m When carrying out any repair or maintenance work, the safety regulations covering work in enclosed areas of sewage installations as well as good general technical pratices should be followed. The maintenance hints given here are not designed for doityourself repairs as special technical knowledge is required. A maintenance contract with our works service department will guarantee you the best technical service under all circumstances. 6.1 Commentary on maintenance of lifting stations in accordance with EN 12056 It is recommended that the lifting station be inspected monthly and its function checked. In accordance with EN regulations, the lifting station should be maintained by a qualified person at the following intervals: in commercial premises every three months. in apartment blocks every six months. in a single family home once a year. In addition we recommend that a maintenance contract be taken out with a qualified company. 6.2 General maintenance hints ABS submersible pumps are reliable quality products each being subjected to careful final inspection. Lubricatedforlife ball bearings together with monitoring devices ensure optimum pump reliability provided that the pump has been connected and operated in accordance with the operating instructions. Should, nevertheless, a malfunction occur, do not improvise but ask your ABS customer service department for assistance. This applies particularly if the unit is continually switched off by the current overload in the control panel, by the thermal sensors of the thermocontrol system or by the seal monitoring system (DI). Regular inspection and care is recommended to ensure a long service life. The ABS service organisation would be pleased to advise you on any applications you may have and to assist you in solving your pumping problems. The ABS warranty conditions are only valid provided that any repair work has been carried out in ABS approved workshop and where original ABS spare parts have been used.

ABS Production Wexford Ltd., Clonard Road, Wexford, Ireland Tel. +353 53 91 63 200 Fax +353 53 91 42335. www.absgroup.com