Micro-Injection System

Similar documents
TS1251 PRESSURE DISPENSER USER'S MANUAL

Backpack Sprayer. Use and Care Manual

WARNING Carefully Read These Instructions Before Use

Page 1 of 19. Part# /10/2006

PENTECH, INC. BD Spray Gun. Operating Manual Parts Manual May, 2008 Issue 1. Plural Component, Impingement Mixing, Mechanical Purge Spray Gun

Quick Start Guide TABLE OF CONTENTS. 1. Remove the dust plugs. (PASW218)

Items # and #

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport

Athletic Field Painting Pointers Line Star Drawing Line Star Parts List 3-4. Spray Boom Drawing Stainless Steel Tank 6

Installation Manual v1.0: The Torque Pro Propane Injection System GM. Please read all instructions before installation.

Safety, Operation and Maintenance Instructions For Long & Short Nose Upholstery Air Stapler (NS10 & NS11)

TERMITICIDE APPLICATION TOOLS

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Air / Hydraulic Pump

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

Cummins 6.7 Litre 2500/3500 Diesel EGR System. Always wear gloves and safety glasses when performing this service

1600 PSI ELECTRIC PRESSURE WASHER

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

VW (Engine Code CJAA/CBEA) 2.0 Liter TDI Diesel EGR Cleaning Instructions. Always wear gloves and safety glasses when performing this service

WALKIE HIGH LIFT HYDRAULIC SYSTEM

CHEM-TEX POWER MAX 25 GOLD EDITION TRUCK MOUNT MANUAL

Shotgun Single Barrel HPFP install guide

Page 1 of 12. Part# /30/2016

Installation Manual TWM Performance Kia Forte Short Shifter

FPC815 Pneumatic Rivet Tool

Manifold Isolation Valves

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Heavy Duty Sprayer Owners Manual Model MS-O

CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS

pulsfog TracFOG 400 F

DISC BRAKE/DUAL MASTER CYLINDER CONVERSION. Tools, Equipment and Supplies Needed:

Tools Needed for Mounting Cleá Filling Station

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

Electric Pressure Washer

Paint/Solvent/Dump Valve and Flow-Through Valve

INSTRUCTIONS DURA SHOT S SPRAYERS DIRECTIONS FOR OPERATING DURA SHOT S. 24 oz. DURA SURE SHOT S SPRAYER.

50:1 Grease Pump Kits

Technical Manual. Table of Contents

Agxcel GX12i Chemical Injection System

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO

New & Improved VariFlo Plural Component Equipment. Low Pressure Polymer Dispensing Equipment

Remove utility bag from plastic and install onto pivot arm with attached straps. Install utility bag with zippers facing away from machine.

SERVICE MANUAL

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS


EGR Adapter VW Passat (Engine Code CKRA) 2.0L TDI

Operation Manual BOTTLE TOP DISPENSER

EXTENDA-BAN VALVE REPAIR AND MAINTENANCE

HydroCycle 6" Pro NFT Lettuce Systems

Instruction Manual. Series E7 Metering Pumps. For file reference, please record the following data:

Installation Guidelines

Installing the Integral Platen Blow Off Valve

#TL T EA888 GEN 3 FUELING SYSTEM/ INSTALLATION INSTRUCTIONS

HydroCycle 4" Pro NFT Lettuce Systems

D-04/G-04 Maintenance

Instructions Parts List

KJ4000LW Operating Instructions & Parts Manual NSN

StratoLauncher IV Assembly Instructions

VW Passat (Engine Code CKRA) 2.0L TDI Diesel EGR Cleaning Instructions

FRP SystemOne GELCOATER OPERATION MANUAL. MAGNUM VENUS PRODUCTS Operation Manual. Part No. M Revision

INSTRUCTIONS Refillable, reusable. Extra versatile. Pressurized by free air

Single Barrel Shotgun HPFP Install Guide

SERVICE MANUAL

Reactor Startup Checklist

MUELLER GAS. Shur StopTM Unit 812 PE Line Stopping. System 8" 12" SDR Reliable Connections. General Information 2

INSTRUCTIONS Refillable, reusable. Extra versatile. Pressurized by free air

Air Hydraulic Rivet Tool

SW9TM, SW14.5TI, SW15TE

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

tubing, faucets and fittings

FPC835M Air Hydraulic Rivet Tool

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

ADVANTAGE Annual Preventive Maintenance Instructions

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL

Warning and Safety Precautions

D-15/G-15 Maintenance

25 GALLON ATV SPRAYER

StratoLauncher IV Ultimate Assembly Instructions [launch video:

STEP 1 STEP 2. Disconnect the negative terminal from both batteries.

Disassembly and Assembly

Maintenance Information

HALLMARK INDUSTRIES INC

BRAKE E

Operating Manual High Viscosity Dispense Valve Item #

Part# JL AIR IT UP 4 Tire On Board Air Delivery System. (Requires External Air Source)

VLW18TE, VLW18TI HYDRAULIC VERTICAL LIFTING WEDGES. Operator Instruction Manual INNOVATION IN ITS MOST FUNCTIONAL FORM

EGR Adapter Ford 6.7 L

Table of Contents WARRANTY

PNEUMATIC SLIDING VALVE

IMPORTANT NOTE The warranty will be void if the pump has been altered in any way

CXL2 Injectors & Manifolds

THANK YOU FOR CHOOSING BATHERBOX GETTING STARTED WHAT S IN THE BOX? N. Northview Ave Sioux Falls, SD 57107

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

SERVICE MANUAL MODEL # ORDER # XPERT-HD 3.8/35 P PD DA DD

Transcription:

QUIK-- Micro-Injection System

Table of Contents Part 1: Getting Started & Using your QUIK-jet Air Parts of the QUIK-jet Air Device...2 Parts of the QUIK-jet Air Kit...3 Air Tank Assembly...4 Connecting the Device...5 Regulator Components...6 Part 2: Micro-Injection Prime the QUIK-jet Air and Ready for Micro-Injection...7 Selecting Arborplugs and Drill bits...8 Setting the Arborplugs...9 Procedure: Conifers vs. Deciduous... 10 Part 3: Maintenance Three step clean out... 11 Regular Maintenance... 13 Lubricating the device... 14 Breaking it down... 15 Putting it back together... 16 Replacement parts/ Internal parts... 17 Additional parts/ Parts for Air Tank... 18 Troubleshooting... 19 1

Parts of the QUIK-jet Air Device PTC Fitting 1/4 PTC 4-Pack 070-0100 Glass Cylinder Case 975-1009 1/8 NPT x #10-32 Adapter 975-1124 Cylinder Case Nut 975-1010 Main Body 975-1001 Piston Rod Housing Plug 975-1003 Stop Nut 975-1005 Piston Rod 975-1004 Dosesizer 975-1006 1/4 Product Tubing 070-0102 Output Check Valve 975-1122 Glass Cylinder 975-1008 Trigger Slider 975-1011 Pull Ring 975-1107 Air Supply Quick-Connect 975-00120 Inlet Check Valve 070-2366 90 Adj. Elbow 975-1128 Safety Reminder Always wear safety glasses and protective gloves (e.g. disposable nitrile) when setting up, operating or maintaining the Arborjet QUIK-jet Air System. Read label of injectable product for further precautions and warnings. 2

Parts of the QUIK-jet Air Kit Kit Includes: 1 QUIK-jet Air device (070-2355) 1 Liter supply bottle (010-9022) 1 Air tank (975-00183) 1 Carrying bag with shoulder strap (975-1123) 1 Arborplug setter (070-0120 sold in 2-pack) 2 Drill bits (3/8 and 9/32 ) (010-4040) 1 Needle cleanout tool (070-0130 sold in 2-pack) 1 Graduated cylinder (070-0104 sold in mixing & measuring kit) 1 Pair of safety glasses (975-00084) 1 Funnel (070-0104 sold in mixing & measuring kit) ½ Liter of CLEAN-jet (030-2030 1 liter for reordering) 1 Training Manual (available online for reference) Low Pressure Regulator with coil (070-2370) 2 Viper Needles (070-0501 sold in 4-pack) Allen Wrench - 5/64 (989-00008) 3

Air tank Assembly Holding regulator assembly still, twist air tank clockwise to tighten. Fill air tank with compressed air only. Most dive/paintball shops can fill air tanks. If the shop does not have the proper filling station, item #975-00039 will be needed. CAUTION: Do not fill with CO 2 CAUTION: Fill to maximum of 3000 psi. You can fill your air tank if you have a personal compressed air tank of your own, all you ll need is part #975-00039N Fill station open/close knob Scuba open/close knob QUIK-jet Air air tank fits here for filling Bleed Valve IMPORTANT Make sure bleed valve is closed when filling air to the tank Be sure to bleed all air from scuba fill station before removing from air tank Be sure to follow full instructions included with item #975-00039N 4

Connecting the Device 1 2 3 4 5 PTC Fitting 7 6 Attach pressure supply line and product tubing: 1. Pull back outer sleeve. 2. Push to connect. 3. Flip device body over so on/off switch faces down. 4. Feed product tubing through channel in body until it passes the front of the body. 5. Push product tubing into PTC fitting. 6. Push the other end of tubing into the inlet check valve. Ensure that the arrow on check valve points towards the device. 7. Connect the tubing from product supply bottle into the other end of check valve. Filling and Attaching Product Supply Bottle 5 1. Load formulation into product supply bottle. Do not load more than 1000 ml of product. 2. Holding product suppply bottle upright, screw bottle clockwise into product bottle top assembly. Ensure product tubing is snugly connected in PTC fitting.

Regulator Components D A A B E D C Side View A. Primary Regulator & Gauge B. Pressure Release Valve C. Air Tank D. Open/Close Valve E. Pressure Supply Gauge Top View Regulator Regulator Gauge (Counter Clockwise) (Clockwise) To adjust the air pressure, insert a 3/16 Allen wrench into end of primary regulator. Turn counter-clockwise slowly to increase pressure to system. Turn clockwise to decrease pressure. Set pressure between 60 100 psi depending on tree. CAUTION: Do not exceed 110 psi 6

Prime the QUIK-jet Air Dose Chamber 1 2 1. Press the ON/OFF switch several times until formulation reaches the dose chamber. 2. Dispense product back into original product bottle or extra supply bottle until you get a full dose inside the chamber. NOTE: Be careful when pointing the needle; some air bubbles may occur. QUIK-jet Air is now primed and ready to use! Ready for Micro-injection System is assembled, pressurized, primed, and ready for microinjection. NOW YOU ARE FULLY ASSEMBLED! When to Micro-Inject Seasonal and environmental conditions that favor uptake of injectable material Time of Year: Active growth tree in full leaf Weather Conditions: Sunny, warm (ideally 60-80 F), breezy, low humidity Soil Conditions: Moist soil conditions, soil temperatures above 40 F 7

Selecting Arborplugs and Drill Bits Select Arborplugs based on tress size and type: For trees of small to medium size and density use #3 (9/32 ) Arborplugs. For large or dense-wooded trees and conifers use #4 (3/8 ) Arborplugs. Arborplug Size Drill Bit Size #3 9/32 #4 3/8 Selecting Arborplug Sites # of Arborplugs = DBH /2 (ex. 16 DBH = 8 sites) Sites are within 36 above the soil line. X The Best Arborplug Injection Zone Root flares show best uptake and formulation distribution to the canopy. Choosing good Arborplug sites result in faster injections. Annual Rings Drilling Sites for Arborplugs Inner Bark Bark Step 1 Use sharp, high-helix brad-point drill bits (included in kit). Drill Bit Drilling in 2 Steps: 1. Use very light pressure to drill through outer bark and inner bark. The drill bit will stop at the xylem. You can remove drill bit to note the bark thickness. 2. Use quick heavy pressure to drill into the xylem. Xylem tissue Inner Bark Bark Try to keep drill steady to ensure properly-set Arborplugs. Estimated drill depth into xylem: Hardwood: 5/8 1 5/8 deep Conifers:1 5/8 2 deep 5/8 2 Drill Bit Step 2 8

Setting the Arborplugs 1. Set Arborplugs into drilled holes using Set Tool (from kit) and hammer. Too Deep Too Shallow 2. Make sure the barbs on the Arborplug make a seal between the xylem and the inner bark as illustrated. Correct Incorrect 9

Micro-Injection with the QUIK-jet Air ON OFF 1. Determine ml dose per injection site (per Arborplug). 2. Insert needle and push switch forward to ON position to apply dose (up to 5 ml). 3. Hold until piston has stopped moving forward; push switch back to OFF position so piston retracts. 4. Repeat dose / injection site until entire dose is in the tree. Procedure: Conifers vs. Deciduous Important Note For Conifer Injections: Sap flows out of conifers as a protective response to drilling. For best results, make sure the QUIK-jet Air is inserted and the micro-injection occurs immediatly after the Arborplug is set. Drill, plug, and inject one site at a time. If too much time has passed between Arborplug setting and QUIK-jet Air application, sap may flow into your injection site and make your uptake slower. Important Note for Deciduous Injections: No sap flows from deciduous trees after drilling. QUIK-jet Air micro-injection can occur after each Arborplug is set, or after all Arborplugs are set in the tree. 10

Three Step Clean-Out IMPORTANT: Prior to switching to another product, or storing the QUIK-jet Air, it is essential to clean and rinse out the device and product tubing to maintain proper function and to avoid clogging the internal components of the system. Cleaning out the system involves a 3-step process: 1. Empty product tubing of product (Fill with AIR) 2. Rinse away residue with CLEAN-jet 3. Empty product tubing of rinse solution (Fill with AIR) IMPORTANT: Water is not recommended as a rinse solution for imidacloprid-based products as these are not compatible with water. All product tubing must be free of both product and rinse solution before re-introducing a new product to the device. Water-based products such as non-mixable fertilizers may be rinsed with water. Cleaning Out the System: 1) Get Everything Out 1. Disconnect product tubing from device. 2. Pull trigger to discharge remaining product from device (about 10mL) into final injection site in tree, or into original product bottle. 3. Turn OFF compressed air. 4. Bleed remaining air out of device and regulator (two methods): A. Slide ON/OFF switch back and forth several times to bleed all air out of system. B. Pull sleeve on Pressure Inlet and press on and off device. Leave Pressure Line disconnected, and set injection device aside. 1 2 3 4 11

Cleaning Out the System: 2) CLEAN-jet Rinse 1. Label a WASTE container to capture residue as it is rinsed out of the device. 2. Store unused chemical in separate bottle or return it to original container. 3. Add at least 30-40 ml of CLEAN-jet to a clean product supply bottle and attach to device. 5. Reconnect air tank and product tubing. 6. Turn Pressure Supply ON to re-pressurize the system. 7. Shoot CLEAN-jet fluid through the device and into the WASTE container. Repeat several times. 8. Disconnect product tubing from product supply bottle. 9. Switch on/off switch several times to empty CLEAN-jet fluid into the WASTE container. Cleaning Out the System: 3) Last steps and disposal 1. Turn OFF compressed air. 2. Bleed remaining air out of device and regulators: A. Switch ON/OFF Switch several times to bleed all air out of system. B. Pull sleeve on Pressure Inlet and press on and off device. 3. Leave pressure line disconnected and set injection device aside. 4. Dispose of waste according to local and state regulations. 5. System is now ready to be loaded with another product or may now be lubricated and stored. 1 2 IMPORTANT: Always follow Daily Maintenance before storing the QUIK-jet Air System. 12

Regular Maintenance To clean out any debris in VIPER Needles: 1. Remove VIPER needle by pushing the Compression Fitting in and pulling on the needle. 2. Push the VIPER Needle Cleanout Tool through the VIPER needle. 1 2 Weekly Maintenance REMINDER: Before proceeding to Weekly Maintenance, be sure To wear safety protection. That pressure supply is OFF. System is depressurized. Product supply bottle is depressurized. Product supply line switch is closed (OFF). That Daily Maintenance is completed. IMPORTANT: Prior to performing maintenance procedures or storing the system after use, it is essential to clean out the device and product tubing to maintain proper function and to avoid clogging. Please Follow these steps when storing the QUIK-jet Air for a prolonged period of time to prevent corrosion to the QUIK-jet Air body, manifold and tools: Store clean and dry equipment. Clean bottles and product tubing using CLEAN-jet. Store bottles empty. Oil metal components, especially Quick Disconnect on manifold and male Quick Disconnect on gun use 3 in 1 oil or WD-40. Spray tools with WD-40 or coat with 3 in 1 oil. 13

Lubricating the Device Add a few drops of 3-in-1 oil to the device Pressure Inlet on the injector. Apply 3-in-1 oil to the Pressure Supply Line Quick- Disconnect, then pull the metal sleeve back and release. Apply grease to o-ring on Piston. Whenever changing pressure supply tanks, apply grease to o-ring on supply bottle s neck. Apply grease to Internal Piston Sleeve Apply grease to Back Housing Plug Seal. 14

Breaking it down Remove Input Valve by taking a 7/16 wrench and turn the screw counter-clockwise. Unscrew case ring by turning it counter-clockwise to free Glass Barrel Case from main body. Remove the Glass Barrel case to reveal the Glass Barrel and Piston. Pull Glass Barrel away from Piston. Turn the Piston at an angle to remove it from the Piston Rod. Using a ½ wrench, unscrew the black housing plug from body by turning it counter-clockwise. 15

Putting it back together Piston O-ring may need replacement over time. See troubleshooting section. If device gets stuck, replace. Push against the Internal Piston Sleeve with Housing Plug. While having the Piston Rod lined up through the hole, engage the threads and turn clockwise. Use a ½ wrench to tighten. Push the Glass Barrel back onto the Piston. Ensure that grease is applied to Piston after each use. Tilt and line up Piston with Piston Rod. Slide the Glass Barrel Case back onto the Glass Barrel. Put the Case ring back over Glass Barrel Case and turn clockwise. Do not tighten yet. Turn the Glass Barrel until all of the measurement readings are lined up and centered. Using a 7/16 wrench, tighten the input valve back onto the Glass Barrel Case. Once the PTC fitting is lined up with the Tubing feed, tighten the Case Ring. Slide tubing through main body and push it in the Push-to-Connect (PTC) fitting. 16

Replacement Parts A. Main Body (975-1001) B. Trigger Bezel (975-1012) C. Trigger Slider (975-1011) D. Trigger Plate Screws (975-1114) E. Plug (975-1109) F. Pull Ring (975-1107) G. Stop Nut (975-1005) H. Adjustable Knob Dosesizer (975-1006) I. Housing Plug (975-1003) J. Set Screw (sold with adjustable knob) K. 1/8 MPT QD Male Plug (975-00120) L. Inlet Check Valve (070-2366) A C F B D E G H I J K L Replacement Parts A. Cylinder Case (975-1009) B. Fluid Piston (975-1007) C. Glass Cylinder (975-1008) D. #111 Tightness O-Ring (975-9448) E. 10-32 to ¼ PTC (975-00078) F. 1/8 Male NPT x 10-32 Female Bushing (975-1124) G. Output Check Valve (975-1122) H. Adj. Threaded Elbow (975-1117) I. Cylinder Case Nut (975-1010) B D F H A C E G I 17

Internal Parts A. Air Piston (975-1002) B. U-Cup Seal (Air Piston) (975-1103) C. Trigger Valve (998-00048) D. Snap Ring (998-00045) E. Stud Stopper (975-1004) F. Housing Plug Seal (975-1104) A B C D E F Additional Parts A. QUIK-jet Air Rebuild Kit (070-2360) B. Bottle Assembly (070-2200) A B Parts for Air Tank A. Scuba Fill Station (975-00039N) B. Tank Filling Adaptor - Dive Shop (975-00039) C. Air Tank 62 cu 3000 PSI (975-00183) D. Low Pressure Regulator Assembly w/ coil (070-2370) E. Air Tank O-Ring (994-20015) A B C D E 18

PROBLEM: Device won t fire Is there compressed gas (air or nitrogen) pressure indicated on the supply gauge? If not, refill bottle (maximum 3000 psi). Is pressure Supply Line attached to the Device Pressure Inlet? Connect by pulling back Quick-Disconnect Sleeve and push onto Device Inlet. Is the Flow Control completely closed? Open the Flow Control by turning the knob counter-clockwise. PROBLEM: Device won t deliver product Is there product in the Product Bottle? Check Product Supply Line. Is the Product Supply Line connected to the device? If not, push Quick-Disconnect Fitting onto Device Product Inlet. Is the delivery pressure (Primary Gauge) at least 35 psi? If not, then device pressure is insufficient to move the shot piston, which delivers product. Overtime the Internal Piston Sleeve may wear down with use and need replacing. PROBLEM: Device leaking from needle Leaking from PTC? Make sure needle is seated properly. Leaking from tip of needle? Replace Check Valve before PTC fitting at front of device. PROBLEM: Product leaking from product supply bottle Is Product Bottle Adapter screwed on tightly? If no, tighten bottle into adapter by turning clockwise (screw on carefully, making sure threads don t cross!) Is gasket in Bottle Adapter worn or damaged? If yes, replace rubber gasket. PROBLEM: Product leaking from Arborplug Arborplug set at incorrect depth. Too shallow - leaks from around injection site Tap Arborplug further into injection site so barbs catch xylem tissue and not bark. Too deep - injection site over-pressurizes and membrane ruptures. Drill, plug, and inject a new site. 19 PROBLEM: Troubleshooting Check Valves The Arborjet QUIK-jet Air System device utilizes 2 check valves: Inlet check valve Exit check valve If there is a problem with flow of product, replace check valves. Note which valve seems to have problems the two check valves on the QUIK-jet Air are not interchangeable.

99 Blueberry Hill Road Woburn, MA 01801 For customer service, call 781-935-9070 or visit us online at www.arborjet.com.