VER 001 Axle Load Scale XTR686 Operating Manual - 1 -
INDEX 1. INTRODUCTION... 3 Installation Precautions 2. MAIN FEATURES... 4 3. TECHNICAL SPECIFICATIONS... 5 Dimension Product specifications 4. HOW TO USE... 6 5. USE OF BATTERY CHARGER... 7 6. DISPLAY & KEYS... 8 7. TEST MODE... 9 8. SET MODE... 10 9. WIRELESS SPECIFICATIONS... 10-2 -
1. INTRODUCTION This operation manual is the specifications for our XTR series. The XTR series is the product of years of design, development, and in-field testing. This XTR series has been designed with reliability, under rigid quality control and with outstanding performance. This MANUAL included with basic technical information about composition of hardware and programmatic functions. Installation Be cautious of below situations, when placing the product on the road. Precautions Please be informed that we re not responsible for any incident or mishap caused by partial modification of this product. To avoid such situation, customers need to contact our customer service team or system installation staff in advance, and any modification should be conducted under our surveillance. Risk of explosion if battery is replaced by an incorrect type. Use only approved enhancements and batteries. Do not connect incompatible products. Use only batteries, chargers, adaptor, and enhancements approved by NUWEIGH for use with this Particular model. The use of any other types may invalidate any approval or warranty, and may be dangerous. For availability of approved enhancements, please check with your dealer. Avoid sudden temperature changes, vibration, wind, water, or excessive dirt. Avoid from the shock of excessive weight. - 3 -
Use away from heavy R.F noise. Keep it dry place. 2. MAIN FEATURES Very light and sturdy aluminum alloyed case Slim(33mm) type Easily customized for special applications. Built in high accuracy load cell Possible to display weight of each wheel or of total wheels Outstanding water resistant and vibration proof effect Built in lithium polymer battery Wireless Communication Weigh in motion - 4 -
3. TECHNICAL SPECIFICATIONS Product specifications Display 5 digit LCD (20mm high) Power Turns scale on and off Function Zero Zero applied load up to 50% of capacity Sum Display sum weight / local weight Light Turn on the back light Indicators Low battery, Zero, Stable AD conversion speed 10~1,000 times/sec Resolution Internal AD resolution : 1,048,576 counts (20 bits) Power Rechargeable lithium polymer battery (3.7V) Charging adaptor DC 5V, 1A 70 hours max. Battery life After low battery lamp is on, the power will be turned off automatically after one hour or five hours. (depends on operating conditions) Temperature -20 ~ 60 Humidity 10 to 95% non-condensing Enclosure Aluminum alloy Load cell 6 Standard 750Ω Bridge Auto Zero Function Standard, can be programmed internally Relation product XTR686ID Platform size 700 500 33-5 -
Product size 917 500 58 Weight 24.3 kg Wireless Type Assembly 4. HOW TO USE ZigBee Adaptor 1EA, Communication wire Axle type Weighing method Sequential method 2 Axle, 2 Plate Synchronous method 2 Axle, 4 Plate Sequential method 4 Axle, 2 Plate (Use dummy plate) Sequential method 4 Axle, 4 Plate Synchronous method 4 Axle, 8 Plate - 6 -
Synchronous method 3 Axle, 6 Plate 5. USE OF BATTERY CHARGER Connect adapter into charge connector (Check if the voltage is 5V 1A). If a battery port is connected with a adaptor properly, RED lamp is on. If it s charged completely, a green lamp is on. (The estimated time for charging is 6~7 hr., but charging time can be subject to be varied according to the battery condition.) - 7 -
6. DISPLAY & KEYS Display Zero lamp: Indicates that scale is stable and at zero Stable lamp : Indicates that weight is Stable Battery lamp : Displays when a battery has to be recharged Keypad Reset scale to zero Increase number in set mode & initialize in weigh in motion. Turn on the back light Turn on and off the scale - 8 -
7. TEST MODE How to use Pressing a ZERO KEY and press ON/OFF KEY at the same time. Then, it turns into a test mode. Used keys : Use to test the scale : Move next menu TEST 1 : Key test Initial display is 0. Press a keyboard that you want to test, and then the display message will be shown. (ZERO KEY:1 / SUM KEY : 2 / LIGHT KEY : 3) If press a LIGHT KEY, it moves into TEST 2. TEST 2 : Display test TEST 2 operates automatically and the whole display is ON. If press the LIGHT Key, it moves into TEST 3. TEST 3 : Load cell test The value is the conversion constant for A/D. The value may be different according to scale models. If a LIGHT KEY, it moves into TEST 4. Please check if the displayed number is easily changed with giving force to a hook. If the displaying number is not changed or remains 0, then it needs the service after sales. TEST 4 : Serial communication test Wait for transmission and reception. ZERO KEY : transmit 1, return receive 1. SUM KEY : transmit 2, return receive 2. LIGHT KEY : transmit 3, moves into TEST 5. TEST 5 : Back light test ZERO KEY : Turn on and off the back light. If press the LIGHT KEY, it moves into the weighing mode. - 9 -
8. SET MODE How to use Pressing a SUM KEY and press ON/OFF KEY at the same time. Then, it turns into a set mode. Used keys : Initialize : Increase in number : Save and next menu Adjustment the speed of weight change (1 9) ex) F01-1:Very fast F01-9:Very slow Automatic Zero Condition (0~9) ex) F02-3 : Compensation for gradual change below 1.5 division. F02-9 : Compensation for gradual change below 4.5 division. Used the calling ID of plate when indicator box is connected (1~9) ex) F03-1 : Device ID is 1 F03-6 : Device ID is 6 ZigBee Wireless (0,1) ex) F04-0 : Not used F04-1 : Used Weigh in motion (0,1) ex) F06-0 : Not used F06-1 : Used 9. WIRELESS SPECIFICATIONS RF frequency range 2400 ~ 2483.5 MHz Output power Max. 4dBm Channel width 2 MHz Frequency offset < ±30ppm Transmit data rate 250Kbps,500Kbps Receiver sensitivity -99dBm (PER <1%) Maximum input level 0dBm RF In/out impedance 50 ohm (TXRF, RXRF) Spurious(2nd harmonics) < -30dBm Radio link effective range Approx. 30~80M (Open space) MEMO - 10 -