CSO/STORMWATER MANAGEMENT. HYDROVEX FluidVertic Vertical Vortex Valve

Similar documents
CSO/STORMWATER MANAGEMENT. HYDROVEX Turbo Flow Regulator

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidGate Control Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidHook Control Gate Valve

CSO/STORMWATER MANAGEMENT. Hydrovex VHV / SVHV Vertical Vortex Flow Regulator

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidMid Flow Monitoring & Regulating Station with Siphon (Type G)

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve

SL B. Grundfos pump GRUNDFOS DATA BOOKLET

neptunetg.com Neptune Technology Group Inc Alabama Highway 229 Tallassee, AL USA Tel: (800) Fax: (334)

Sewage transport Submersible pumps

HTX-HTH SEPARATORS I&O MANUAL

HP Turbine Installation and Maintenance Guide

pneumatic outflow control

Sempell High Pressure Stop Valves Model VA500 (DIN)

TRU/FLO Compound Installation and Maintenance Guide

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

GIS/ GISO Series End Suction Pumps TECHNICAL BULLETIN

SC-1 1 Empty/Load Equipment

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

SEV D. Grundfos Pump GRUNDFOS DATA BOOKLET

DSV. Operating Manual. Double Seal Butterfly Valve. Read and understand this manual prior to operating or servicing this product.

SENSOFIT RET 5000 Technical Datasheet

Series description: Wilo-Drain MTC

Circuit Regulating Valve STRÖMAX GF

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Best Practice Variable Speed Pump Systems

WATERFLUX 3070 Quick Start

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Hopkinsons CONTENTS SCHEDULE OF SHELL BOILER MOUNTINGS. Hopkinsons. Safety Valves 5. Boiler Stop Valves 17. Feed Check Valves 18. Blowdown Valves 20

GRAF EcoBloc Stormwater Management System

SE M.C.N.51D

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

MGA and RGA SERIES SPLIT-SHAFT PTO DRIVE GEARBOX INSTALLATION MANUAL

Dewatering Submersible sewage pumps

ELECTRIC SUBMERSIBLE PUMPS SEMISOM/80

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Sempell High Pressure Stop Valves Model VA510 (DIN)

Series description: Wilo-Drain TM/TMW/TMR 32

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

Pressure Reducing Valve Type 2114/2415

First Defense. Stormwater Treatment System. Operation and Maintenance Manual

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials.

Recold JW Series. Lenntech. Tel Fax ENGINEERING DATA AND SPECIFICATIONS

Change-Over Pressure Filter DFDK

MODEL 5A SPECIFICATION

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

Troubleshooting. This section outlines procedures for troubleshooting problems with the operation of the system:

ABS submersible sewage pump AFP

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.

KIRLOSKAR ROMAK PUMP - RMK ISO 2858 / DIN EN / ISO 5199

Conductivity Measuring Cells ConduMax W CLS 19

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody

HYDROMATIC SKHS SERIES SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

DWK.E D.R

MVD, MV, MKV, MKL, 2161C, MXV Series

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Heavy duty slurry pumps

Date: Project #: Engineer: Prepared By: Bid Date:

Hydraulic Shock and Sway Suppressors ( Hydraulic Snubbers )

our contribution for environmental protection Sealless magnetic coupled centrifugal pumps acc. to EN Type NML / NMB

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Lithium-Ion Battery-Powered Tools

MANUFACTURERS OF HIGH PURITY COMPONENTS FOR PHARMACEUTICAL APPLICATIONS

HTM Circulation Pumps acc. to DIN EN 733 Type NKLs

GRUNDFOS WASTEWATER. S range kw. 50 and 60 Hz versions

OVERVIEW OPERATION. 2 Stormceptor EF Technical Manual

Sempell High Pressure Stop Valves Model VA500 (ASME)

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

ARKAL FILTERS CATALOGUE

FIXED CONE VALVE. The flow is guided by the inner vanes, in order to decrease the vortex and the vibration;

Heavy duty slurry pumps

SERVICE & OPERATING MANUAL

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

AUTOMATIC CONTROL VALVES BY RAPHAEL

MODEL 7ASX-8 SPECIFICATION

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

Valves, controls + systems Cast iron double regulating/ commissioning valves PN 16 Hydrocontrol G

Right Angle Nozzle Assembly

CATALOGUE SEWAGE MANHOLES

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

The World Leading Air-conditioning Company

FPO 80 FPOC FPOS FPON, FPOS Tank truck vane pump

Fire Block and Pressed Steel Grilles

GRAF EcoBloc Stormwater Management System

GD series Submersible Grinder Pump

Operation & Maintenance Manual For 4900 Series Pumps Bulletin 134

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

Return Line Filter RF

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.

Type 80 Wafer and Type 81 Bolt-Thru Isolation Rings. Installation, Maintenance and Safety Instructions

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

Transcription:

CSO/STORMWATER MANAGEMENT HYDROVEX FluidVertic Vertical Vortex Valve

HYDROVEX FLUIDVERTIC VERTICAL VORTEX VALVE APPLICATION The HYDROVEX FluidVertic Vertical Vortex Valves is a special form of the previously tried and tested vortex flow regulators SVHV. They operate without any moving parts and do not require any auxiliary power. The throttling effect is produced solely by fluid dynamics. For such large open cross sectional areas, vortex valves develop very high flow resistances. The HYDROVEX FluidVertic Vertical Vortex Valves are especially applicable in Stormwater and Storm Drain flow control. Some examples of applications are; control of street and car park drainage, control of fluid flow in Stormwater retention basin, etc. ADVANTAGES Large open cross sections No moving parts No wear No auxiliary power required High operational reliability Corrosion free construction Accurate flow control Simple variation of flowrate Simple and quick installation No adjustment necessary CONSTRUCTION AND OPERATION The vortex chamber (a) is positioned vertically (see Figure 1). The inlet pipe (b) is arranged tangentially to the vortex chamber. The outlet (c) is positioned horizontally in the center of the vortex chamber. An interchangeable outlet aperture (d) allows some alteration of the specified flowrate. The HYDROVEX FluidVertic Vertical Vortex Valves are installed in a "wet" chamber, (i.e. they are permanently immersed in water during operation) and can be mounted onto the inner wall of the water tank. The valve inlet of the HYDROVEX FluidVertic Vertical Vortex Valve is permanently submerged because the liquid level never falls below the lower edge of the aperture (d). As a consequence, the valve also acts as a trap, catching low-density fluids such as gas and oil. As the water level rises in the valve chamber, the air escapes through the venting hole (e), allowing the chamber to become partially filled. At this point, the flow resistance is low and the flowrate high. However, if the water level rises above the apex of the vortex chamber, the flow forms a vortex with an air-filled vortex core. The valve is now in throttle mode, where the flow resistance is large and the flowrate comparatively small. There are currently two types of HYDROVEX FluidVertic Vertical Vortex Valves:

Type VSU Model VSU, shaped like a doughnut, has a large flow resistance and is especially applicable when extremely small flowrates are desired and there is a certain risk of obstructions clogging the inlet or outlet (see Figure 1). Figure 1: HYDROVEX FluidVertic Vertical Vortex Valve and flow patterns Type VSL The chamber of model VLS has level sides and is in the shape of a logarithmic spiral (a), with a square inlet. As a rule, the valves are supplied with a wall-mounting bracket, which interlocks with another plate on the back of the valve. The valve can easily be slid out of the wall-mounting bracket and winched up for inspection or removal of blockages. Devices that use small nominal diameters can be slipped directly into the outlet pipe by using an adaptor. Figure 3: Dimensioning elements of the HYDROVEX FluidVertic Vertical Vortex Valve

FLOW CHARACTERISTICS Vortex valves have s-shaped flow curves (see Figure 2). The lower leg indicates the flow regime when the vortex chamber is partially filled. The upper section shows the increased hydraulic resistance caused by the vortex flow. The valve discharge can be regulated in the ratio 1:1.8 by changing the outlet aperture (d). Figure 2: Typical flow curve of a HYDROVEX FluidVertic Vertical Vortex Valve HYDRAULIC DIMENSIONS The design pressure head h b is defined as the water level difference between the high liquid level, (ex: the upper edge of the tank overflow weir) and the axis of the valve. The flowrate can be adjusted between Q min and Q max (see Table 1). The design pressure head should be greater than h hmin in order to obtain an optimum throttle action. Nominal Diameter DN 40 50 65 80 100 125 150 Operational range of h = 2m Type of regulator Q en l/s Q en l/s Q en l/s Q en l/s Q en l/s Q en l/s Q en l/s min max min max min max min max min max min max min max VLS 1:4 2,0 3,7 3,1 5,6 5,1 9,1 7,6 13,6 11,6 20,8 18,0 32,4 25,7 46,2 VLS 1:6 1,4 2,5 2,1 3,8 3,4 6,2 5,1 9,2 7,9 14,2 12,2 22,0 17,5 31,5 VSU 1:4 1,3 2,4 2,0 3,7 3,3 6,0 5,0 9,0 7,7 13,8 11,9 21,4 17,2 30,9 VSU 1:6 1,1 2,0 1,7 3,1 2,8 5,1 4,2 7,6 6,5 11,8 10,1 18,3 14,5 26,1 Minimum water level h bmin (m) Type 1:4 0,16 0,20 0,26 0,32 0,40 0,50 0,60 Type 1:6 0,20 0,25 0,32 0,40 0,50 0,62 0,75 Table 1: Operating range and minimum pressure head The valves are delivered ready to be installed. We guarantee an accuracy of ±5% of the design flowrate for the corresponding design pressure head. Installation adjustments are not necessary.

DIMENSIONS AND MATERIAL Table 2 contains the most important dimensions for all models and nominal bore. It is standard for the valve housing to be manufactured in stainless steel. Both the back plate and pipe bracket are made of PVC. Type VSU 1:4 A 132 173 214 260 322 402 482 d 125 125 135 162 200 250 300 e 129 146 175 197 231 291 331 B 250 250 270 324 400 500 600 H 277 338 409 490 587 717 847 b min 172 223 279 340 422 527 632 Type VSU 1:6 A 167 206 272 339 410 513 615 d 125 150 200 250 300 375 450 e 154 175 213 251 289 365 422 B 250 300 400 500 600 750 900 H 342 416 532 649 771 948 1125 b min 207 256 337 419 510 638 765 Type VLS 1:4 A 95 115 141 173 225 268 322 d 125 125 135 150 175 214 257 e 106 116 131 146 166 211 236 B 250 250 270 300 350 419 492 H 240 280 316 373 445 523 607 b min 135 165 206 253 325 393 472 Type VLS 1:6 A 126 156 202 248 310 387 463 d 125 139 180 220 275 343 410 e 106 116 131 146 166 211 236 B 250 264 327 401 499 623 746 H 286 341 427 513 625 761 903 b min 166 206 267 328 410 512 613 INSTALLATION AND MAINTENANCE Installation of the HYDROVEX FluidVertic Vertical Vortex Valve is very simple. The appliance is delivered ready for operation with all seals and fastenings. The wall bracket must be bolted into the vertical tank wall, such that it is aligned both vertically and horizontally with the axis of the outlet. Vertical vortex valves operate without any moving parts and require little or no maintenance, as they have no wear. Nevertheless, we recommend that a visual inspection be carried out to ensure that the inlet is not blocked. We also recommend that, from time to time, the housing should be winched off its wall bracket and the inner chamber be inspected. SPECIFICATIONS HYDROVEX FluidVertic Vertical Vortex Valve, type VSU/VLS nominal diameter DN:... mm set-point rate: Q:... l/s water level h b:... mce material: stainless steel to nickel chrome and PVC Device regulated at set-point rate, including sealing and fastening elements, steel remote disassembling rope, descriptive and dimensional notes, start-up manual. John Meunier Inc. ISO 9001 : 2000 Head Office 4105 Sartelon Saint-Laurent (Quebec) Canada H4S 2B3 Tel.: 514-334-7230 www.johnmeunier.com Fax: 514-334-5070 cso@johnmeunier.com Ontario Office 2000 Argentia Road, Plaza 4, Unit 430 Mississauga (Ontario) Canada L5N 1W1 Tel.: 905-286-4846 www.johnmeunier.com Fax: 905-286-0488 ontario@johnmeunier.com USA Office 2209 Menlo Avenue Glenside, PA USA 19038 Tel.: 412-417-6614 www.johnmeunier.com Fax: 215-885-4741 asteele@johnmeunier.com Revised : 2008-10-01