Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Similar documents
Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Ex-proof ISO cartridge valves multicertification ATEX, IECEx, EAC or North American certification CULUS directional control, ISO 7368

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification

Solenoid directional valves type DHAL8 and DHWL8 direct operated, ISO 4401 size 06, ex-proof or intrinsically safe, low leakage execution

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Proportional reducing valves

Proportional relief valves

Proportional reducing valves

Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32

Proportional relief valves with integral pressure transducer

Proportional reducing valves

Pressure relief valves type ARAM

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

Proportional relief valves with integral pressure transducer

SOLENOID DIRECTIONAL VALVE

Proportional reducing valves with integral pressure transducer

Proportional pressure reducing cartridges type LIRCZO normally closed, ISO 7368 sizes from 16 to 40

ISO cartridge valves type LIM*, LIRA, LIC*

Proportional relief valves with integral pressure transducer

VSD*HL-*-KD2 - HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

Q max (see specifications table)

Proportional flow valves

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

ISO cartridge valves type LIDEW* and LIDBH*

Safety cartridge valves with poppet position monitoring

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

2/2 Solenoid Cartridge Valve, Size 6

INSTRUCTION MANUAL (ATEX / IECEx)

VALIADIS S.A. HELLENIC MOTORS

Complementary safety valves with /FC mechanical microswitches conforming to Machine Directive 2006/42/CE

Directional spool valves, direct operated, with solenoid actuation. Type WE. Contents. Features. RE Edition: Replaces:

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Servo solenoid valves with on-board electronics (OBE)

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

The safety you rely on.

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces:

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Safety directional valves with spool position monitoring

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Ex m Solenoid Operator Type 0519

Servo solenoid valves with on-board electronics (OBE)

3/2 and 4/2 directional seat valves with solenoid actuation

INSTRUCTION MANUAL (ATEX / IECEx)

Proportional directional valves type DHZO-AES and DKZOR-AES direct operated, without position transducer, ISO 4401 size 06 and 10

Servo solenoid valves with on-board electronics (OBE)

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Floodlight LED Series 6125

General Specifications DRV DRV-Exm DRV-Exd

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

Sentronic PLUS 614 Series

Solenoid coils VACF Type codes

Operating Instructions

VED*MJ PILOT OPERATED DIRECTIONAL CONTROL VALVES WITH OBE & FEEDBACK

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Terminal Boxes Series 8125

Proportional pressure control cartridges with integral pressure transducer

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Proportional pressure reducing valve, pilot operated

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

VSD*S -MONITORED DIRECTIONAL CONTROL VALVES

Compact Sheet-Steel Light Fittings Series 6114/1

Proportional Pressure Relief Valve Series RE*T

Explosion proof electric motor For Fuel dispensing application. Main characteristic

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

CCAI, CCAIF, CCAIF..H

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer

YFC. Limit switch. Ex d. 24 operating head types

Chapter 2: Directional Control Valves

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Proportional Solenoid for Hydraulics ATEX + IECEX

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Spring loaded resistance thermometer

VER03M CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES VER03M - PROPORTIONAL PRESSURE RELIEF VALVES

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Safety valves direct, pilot operated and cartridge execution

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Ex-proof proportional valves multicertification ATEX, IECEx, EAC

ExBin-P Pressure switches 5 Pa Pa

Transcription:

Table FX1-/E Replaces F6-5 /E E125-16 /E Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Valve main body Cartridge Mechanical pressure limiter Ex-proof pilot valve T P X X AGMZA-A-1-* RZMA-A, HZMA-A, AGMZA-A Ex-proof proportional relief valves direct or pilot operated, without transducer for open loop pressure controls. They are equipped with ex-proof proportional solenoid, certified for safe operations in hazardous environments with potentially explosive atmosphere. Certifications: Multicertification ATEX, IECEx and EAC for gas group II 2G and dust category II 2D Multicertification ATEX and IECEx for gas group I M2 (mining) culus North American certification for gas group C&D RZMA, direct or pilot operated: Size: 6 - ISO 41 Max flow: 4 and l/min HZMA, direct or pilot operated: Size: 6 - ISO 41 Max flow: l/min AGMZA, pilot operated: Size: 1, and 2 - ISO 6264 Max flow:, and 6 l/min Max pressure: 25 bar 1 MODEL CODE RZMA / * - A - 1-25 / GK / * / * ** / * Ex-proof proportional pressure relief valves RZMA = subplate size 6 HZMA = modular size 6 AGMZA= subplate size 1,, 2 Series number Seals material, see section 7 : - = NBR PE = FKM BT = HNBR (2) Certification type: Multicertification ATEX, IECEx, EAC: - = omit for Group II 2G / 2D (1) M = Group I M2 (mining) North American Certification: UL = CULUS Voltage code: - = standard coil for 24 VDC Atos drivers 24 = optional coil for 24 VDC low current drivers A = without transducer Valve size and configuration: 1 = RZMA size 6 Qmax 4 l/min = RZMA size 6 Qmax l/min = HZMA size 6 Qmax l/min 1 = AGMZA size 1 Qmax l/min = AGMZA size Qmax l/min 2 = AGMZA size 2 Qmax 6 l/min Max regulated pressure: = bar 1= 1 bar 25= 25 bar Options (): E = external pilot (only for AGMZA) O = horizontal cable entrance (2) Y = external drain (only for AGMZA) Solenoid threaded connection for cable gland fitting: GK = GK-1/2 - not for CULUS M = Mx1,5 - not for CULUS NPT = 1/2 NPT (1) The valves with Multicertification for Group II are also certified for Indian market according to PESO (Petroleum and Explosives Safety Organization). The PESO certificate can be downloaded from www.atos.com (2) Not for multicertification M group I (mining) () Possible combined options: /EO, /EY, /OY The pressure at T port makes difficult the manual override operation that can be possible only if its value is lower than 5 bar 2 CONFIGURATIONS AND HYDRAULIC SYMBOLS (representation according to ISO 1219-1) RZMA-A-1 RZMA-A- HZMA-A- AGMZA-A-* A1 P1 T1 B1 M T A B P A P T B FX1

ELECTRONIC DRIVERS Electronic drivers are factory set with max current limitation for ex-proof valves. Please include in the driver order also the complete code of the connected ex-proof proportional valve. Drivers model E-BM-AS-* /A E-BM-AES-* /A Type digital digital Format DIN-rail panel Data sheet G GS5 4 GENERAL CHARACTERISTICS Assembly position Any position Subplate surface finishing Roughness index, Ra,4 flatness ratio,1/1 (ISO 111) MTTFd valves according to EN ISO 1849 75 years; 15 years only for RZMA-1, see technical table P7 Ambient temperature range Standard = - C +7 C /PE option = - C +7 C /BT option = - C +7 C Storage temperature range Standard = - C + C /PE option = - C + C /BT option = - C +7 C Surface protection Zinc coating with black passivation (body and solenoid housing) Compliance Explosion proof protection, see section 8 5 HYDRAULIC CHARACTERISTICS - based on mineral oil ISO VG 46 at 5 C Valve model Size code Valve size Max regulated pressure Min regulated pressure Max pressure at port P, A, B, X Max pressure at port T, Y Max flow Response time -1% step signal (depending on installation) (1) [bar] [bar] [bar] [bar] [l/min] [ms] RZMA HZMA AGMZA 1 1 2 6 2 1 25 see min. pressure / flow diagrams at sections 15 16 17 15 21 4 6 Hysteresis[% of the max pressure] 1,5 Linearity[% of the max pressure] Repeatability[% of the max pressure] 2 7 1 Note: above performance data refer to valves coupled with Atos electronic drivers, see section (1) Average response time value; the pressure variation in consequence of a modification of the reference input signal to the valve is affected by the stiffness of the hydraulic circuit: greater is the stiffness of the circuit, faster is the dynamic response 6 ELECTRICAL CHARACTERISTICS Max. power Insulation class Protection degree with relevant cable gland Duty factor Voltage code Coil resistance R at C Max. solenoid current 5W H (1 ) Due to the occuring surface temperatures of the solenoid coils, the European standards ISO 172-1 and EN982 must be taken into account Multicertification: IP66/67 to DIN EN6529 UL: raintight enclosure, UL approved Continuous rating (ED=1%) standard option /24,2 Ω 17,6 Ω 2,5 A 1,1 A 7 SEALS AND HYDRAULIC FLUIDS - for other fluids not included in below table, consult our technical office NBR seals (standard) = - C +6 C, with HFC hydraulic fluids = - C +5 C Seals, recommended fluid temperature FKM seals (/PE option) = - C + C HNBR seals (/BT option) = - C +6 C, with HFC hydraulic fluids = - C +5 C Recommended viscosity 1 mm 2 /s - max allowed range 15 mm 2 /s Max fluid contamination level normal operation ISO46 class 18/16/1 NAS168 class 7 longer life ISO46 class 16/14/11 NAS168 class 5 Hydraulic fluid Suitable seals type Classification Ref. Standard Mineral oils NBR, FKM, HNBR HL, HLP, HLPD, HVLP, HVLPD DIN 51524 Flame resistant without water FKM HFDU, HFDR Flame resistant with water (1) NBR, HNBR HFC see also filter section at www.atos.com or KTF catalog ISO 12922 The ignition temperature of the hydraulic fluid must be 5 C higher than the max solenoid surface temperature (1) Performance limitations in case of flame resistant fluids with water: -max operating pressure = 21 bar -max fluid temperature = 5 C

8 CERTIFICATION DATA Valve type Certifications Solenoid certified code Type examination certificate (1) Method of protection Temperature class Surface temperature Ambient temperature (2) Applicable standards RZMA, HZMA, AGMZA RZMA/M, HZMA/M, AGMZA/M RZMA/UL, HZMA/UL, AGMZA/UL Multicertification Group II Multicertification Group I North American ATEX IECEx EAC ATEX IECEx CULUS ATEX: CESI 2 ATEX 14 IECEx: IECEx CES 1.1x EAC: TC RU C-IT. 8.B.1784 T4 15 C - + C MZA-A MZAM-A OZA-A/EC T C - +7 C ATEX: CESI ATEX 57x IECEx: IECEx CES 12.7x ATEX 14/4/EU ATEX 14/4/EU Ex II 2G Ex d IIC T4/T Gb Ex I M2 Ex db I Mb Ex II 2D Ex tb IIIC T15 C/T C Db IECEx IECEx Ex db I Mb Ex d IIC T4/T Gb Ex tb IIIC T15 C/T C Db EAC Ex II 2G Exd IIC T4/T EN 679-: 12+A11:1 EN 679-1:14 EN 679-1:14-15 C - +6 C IEC 679-:17 IEC 679-1:17-4 IEC 679-1:1 1724 - E661 UL 1 Class I, Div.I, Groups C & D Class I, Zone I, Groups IIA & IIB T4 T 15 C C - +55 C - +7 C UL 1 and UL429, CSA 22.2 n -1986 CSA 22.2 n 19-1 Cable entrance: threaded connection vertical (standard) or horizontal () GK = GK-1/2 M = Mx1,5 NPT = 1/2 NPT (1) The type examinator certificates can be downloaded from www.atos.com (2) The solenoids Group II and CULUS are certified for minimum ambient temperature - C In case the complete valve must withstand with minimum ambient temperature of - C, select /BT in the model code 1/2 NPT WARNING: service work performed on the valve by the end users or not qualified personnel invalidates the certification 9 EX PROOF SOLENOIDS WIRING Multicertification culus certification n 4 M4 locking torque 4Nm n 4 M4 locking torque 4Nm Standard version Option /O Standard version Option /O cover with threaded connection for vertical cable gland fitting cover with threaded connection for horizontal cable gland fitting terminal board for cables wiring screw terminal for additional equipotential grounding cover with threaded connection for vertical cable gland fitting cover with threaded connection for horizontal cable gland fitting terminal board for cables wiring 1 = Coil 2 = GND = Coil PCB poles terminal board suitable for wires cross sections up to 2,5 mm 2 (max AWG14) 1 = Coil + 2 = GND = Coil - Pay attention to respect the polarity PCB poles terminal board suggested cable section up to 1,5 mm 2 (max AWG16), see section 1 note 1 alternative GND screw terminal connected to solenoid housing FX1

1 CABLE SPECIFICATION AND TEMPERATURE - Power supply and grounding cables have to comply with following characteristics: Multicertification Group I and Group II Power supply: section of coil connection wires = 2,5 mm 2 Grounding: section of internal ground wire = 2,5 mm 2 culus certification: section of external ground wire = 4 mm 2 Suitable for use in Class I Division 1, Gas Groups C Armored Marine Shipboard Cable which meets UL 19 Tinned Stranded Copper Conductors Bronze braided armor Overall impervious sheath over the armor Any Listed (UBVZ/ UBVZ7) Marine Shipboard Cable rated V min, 15A min. C 2,5 mm 2 (14 AWG) having a suitable service temperature range of at least -25 C to +11 C ( /BT Models require a temperature range from - C to +11 C) Note 1: For Class I wiring the C 1,5 mm 2 AWG 16 cable size is admitted only if a fuse lower than 1 A is connected to the load side of the solenoid wiring. 1.1 Cable temperature The cable must be suitable for the working temperature as specified in the safety instructions delivered with the first supply of the products. Multicertification Max ambient temperature [ C] Temperature class Max surface temperature [ C] Min. cable temperature [ C] Goup I Goup II Goup I Goup II Goup I Goup II C - T4 15 C - 9 C - 45 C - T4 15 C 15 C - 9 C 55 C - T 15 C C - 11 C 6 C - - 15 C - 11 C - 7 C N.A. T N.A. C N.A. 1 C culus certification Max ambient temperature [ C] Temperature class Max surface temperature [ C] Min. cable temperature 55 C T4 15 C 1 C 7 C T C 1 C 11 CABLE GLANDS - only Multicertification Cable glands with threaded connections GK-1/2, 1/2 NPT or Mx1,5 for standard or armoured cables have to be ordered separately, see tech. table KX6 Note: a Loctite sealant type 545, should be used on the cable gland entry threads 12 OPTIONS For alla valves: O = Horizontal cable entrance to be selected in case of limited vertical space. Only for AGMZA: E = External pilot option to be selected when the pilot pressure is supplied from a different line respect to the P main line. With option E the internal connection between port P and X of the valve is plugged. The pilot pressure must be connected to the X port available on the valve s mounting surface or on main body (threaded pipe connection G ¼ ). AGMZA-*/E Blinded plug SP-X1A Only for AGMZA: Y = The external drain is mandatory in case the main line T is subjected to pressure peaks or it is pressurized. The Y drain port has a threaded connection G ¼ available on the pilot stage body. AGMZA-*/Y 6 12.1 Possible combined options: /EO, /EY, /OY

1 MECHANICAL PRESSURE LIMITER - only for AGMZA The AGMZA are provided with mechanical pressure limiter acting as protection against overpressure. For safety reasons the factory setting of the mechanical pressure limiter is fully unloaded (min pressure). At the first commissioning it must be set at a value lightly higher than the max pressure regulated with the proportional control. For the pressure setting of the mechanical pressure limiter, proceed according to following steps: apply the max reference input signal to the valve s driver. The system pressure will not increase until the mechanical pressure limiter remains unloaded. turn clockwise the adjustment screw until the system pressure will increase up to a stable value corresponding to the pressure setpoint at max reference input signal. turn clockwise the adjustment screw of additional 1 or 2 turns to ensure that the mechanical pressure limiter remains closed during the proportional valve working. adjustment screw locking nut 6 11 protection cap 14 REMOTE PRESSURE UNLOADING - only for AGMZA The P main line can be remotely unloaded by connecting the valve X port to a solenoid valve as shown in the below scheme (venting valve). This function can be used in emergency to unload the system pressure by-passing the proportional control. 15 DIAGRAMS RZMA-1 (based on mineral oil ISO VG 46 at 5 C) Pressure at port P [% of the max.] 1 Regulation diagrams with flow rate Q = 1 l/min 1 6 1 6 1 Reference signal [% of the max] Pressure at port P [bar] 2 Pressure/flow diagrams with reference signal set at Q = 1 l/min 2 2 2 16 1 1 2 4-5 Min. pressure/flow diagrams with zero reference signal Min. regulated pressure [bar] 15 1 5 1 2 4 5 4 Note: the presence of counter pressure at port T can affect the pressure regulation and the minimum pressure = RZMA/ 4 = RZMA/1 5 = RZMA/25 16 DIAGRAMS RZMA-, HZMA- (based on mineral oil ISO VG 46 at 5 C) 1 Regulation diagrams with flow rate Q = 1 l/min Pressure at port P [% of max] 1 6 1 Pressure at port P [bar] 2 Pressure/flow diagrams with reference signal set at Q = 1 l/min 2 2 16 1 2 Min. pressure/flow diagrams with zero reference signal 6 1 1 8 16 24 2 Reference signal [% del max] Minimum regulating pressure [bar] 1 8 6 4 2 Note: the presence of counter pressure at port T can affect the pressure regulation and the minimum pressure FX1

17 DIAGRAMS AGMZA (based on mineral oil ISO VG 46 at 5 C) 1 = Regulation diagrams with flow rate Q = 5 l/min 2 = Pressure/flow diagrams with reference signal set at Q = 5 l/min Pressure at port P [% of the max] 1 5 1 2 6 Pressure at port P [bar] 2 21 1 7 6 1 6 1 Reference signal [% of the max] Flow [%] -5 = Min. pressure/flow diagrams with zero reference signal = AGMZA-*-1 4 = AGMZA-*- 5 = AGMZA-*-2 Min. regulated pressure [bar] 15 1 5 4 5 7 Min. regulated pressure [bar] 28 21 14 1 15 45 6 18 FASTENING BOLTS AND SEALS 18.1 RZMA and HZMA valves RZMA-A-1 RZMA-A- HZMA-A- 4 socket head screws M5x5 class 12.9 Tightening torque = 8 Nm 4 socket head screws M5x5 class 12.9 Tightening torque = 8 Nm 4 socket head screws M5 class 12.9 Tightening torque = 8 Nm 2 OR 18 Diameter of ports P, T: Ø 5 mm 4 OR 18 Diameter of ports P, T: Ø 7,5 mm 4 OR 18 Diameter of ports P, A, B, T: Ø 6,5 mm 18.2 AGMZA valves AGMZA-A-1 AGMZA-A- AGMZA-A-2 4 socket head screws M12x5 class 12.9 Tightening torque = 125 Nm 4 socket head screws M16x5 class 12.9 Tightening torque = Nm 4 socket head screws Mx6 class 12.9 Tightening torque = 6 Nm 2 OR 12 Diameter of ports P, T: Ø 14 mm 1 OR 19/7 Diameter of port X: Ø,2 mm 2 OR 4112 Diameter of ports P, T: Ø 24 mm 1 OR 19/7 Diameter of port X: Ø,2 mm 2 OR 411 Diameter of ports P, T: Ø 28 mm 1 OR 19/7 Diameter of port X: Ø,2 mm

19 INSTALLATION DIMENSIONS FOR RZMA and HZMA [mm] RZMA-A-1 ISO 41: 5 (see table P5) Mounting surface: 41--2--5 (without ports A and B) RZMA-A-1 2,7 Option /O +,5 45 RZMA-A-1* 68.5 18.5 for UL 98.5 for UL 8.5 11.5 66 25 24 49 RZMA-A- ISO 41: 5 (see table P5) Mounting surface: 41--2--5 (ports A and B connected to port T) RZMA-A-,7 Option /O +,5 45 RZMA-A-* 8 16 11.5 85.6 HZMA-A-* 5 86.5 45 68.5 18.5 for UL 98.5 for UL 25 24 49 HZMA-A- ISO 41: 5 (see table P5) Mounting surface: 41--2--5 HZMA-A-,7 Option /O +,5 16 11.5 85.6 FX1

15 19 INSTALLATION DIMENSIONS FOR AGMZA [mm] AGMZA-A-1 ISO 6264: 7 (see table P5) Mounting surface: 6264-6-9-1-97 AGMZA-A-1 6, Option /O +,5 1 12 AGMZA-A- ISO 6264: 7 (see table P5) Mounting surface: 6264-8-1-1-97 25 214.5 for UL, 21.5 for /O 11 126 AGMZA-A-2 ISO 6264: 7 (see table P5) Mounting surface: 6264-1-17-1-97 (with M fixing holes instead of standard M18) 24.5 1.5 for UL, 218.5 for /O 115.5 AGMZA-A- 7,5 Option /O +,5 116 115.5 AGMZA-A-2 8,9 Option /O +,5 116 214.5 for UL, 21.5 for /O 115.5 1 52 126 21 RELATED DOCUMENTATION X1 TT291 TT54 KX6 P5 General guideline for ex-proof components Safety instruction for Multicertification Atex, IECEx, EAC - Group II Safety instruction for Multicertification Atex, IECEx - Group I Mining Cable glands for ex-proof valves Mounting surfaces for electrohydraulic valves 1/19