WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

kva kw r.p.m V V Cos Phi Ambient conditions of reference: 1000 mbar, 25ºC, 30% relative humidity. Power according to ISO 3046 normative.

WPS60/S EP Series. Features:

kva kw Rated Speed Standard Voltage r.p.m V V Cos Phi Rated at power factor

WPS150/S EP Series. Features:

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

WPS20/S EP Series. Features:

WPS100/S EP Series. Features:

WPS350/S EP Series. Features:

kva kw r.p.m V V Cos Phi Ambient conditions of reference: 1000 mbar, 25ºC, 30% relative humidity. Power according to ISO 3046 normative.

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

WPS250/S EP Series. Features:

MCS900-1(KTA38-G2A) Generating set Technical Data Sheet

MVS230-1(TAD734GE) Generating set Technical Data Sheet

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

Rental Power QSB7 series engine

GMS100C/S EC Series. Features:

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

70 KW / 90 KVA POWERED by

Diesel generator set QSL9 series engine

KP-C40P(4BT3.9-G1) Generating set Technical Data Sheet

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Rental Power QSL9 series engine

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

RG Power Generator

Diesel Generator Set S3.8 Series Engine

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

GMS200C/S EC Series. Features:

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Spark-ignited generator set

APD-ULJ250. Standby Power

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

CGT Stamford UCI 274 E1

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

RENTAL DIESEL GENERATOR SET

KVA KW. Available Voltages V 480/ / / /120 Rated at power factor Cos Phi 0.8

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

RG Power Generator

Spark-ignited generator set

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

GMS350C/S EC Series. Features:

Model NA 2 L

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

60 KW / 75 KVA POWERED by

Diesel generator set QSK78 series engine

CUKUROVA GENERATOR SYSTEMS

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Technical Data V DIESEL TCM500 (Open) LSA47.2M7 Optioanl: Stamford HCI544D. TCM500C (Silent) Tide TPA354S2. Alternator: Leroy-somer

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

Technical specification

KVA KW. Available Voltages V 480/ / / /120 Rated at power factor Cos Phi 0.8

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Rating Definitions and Conditions

RG16-R RG20-R Power Generator

PGDLS352KW 380/ / / / / / / / /

1000 Series 1004G Diesel Engine ElectropaK Belt-Driven Coolant Pump

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PGDLS / / / / / / / / /

Diesel generator set QSK23 series engine

60 Hz FEATURES. Exclusively from your Caterpillar dealer

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

Rental Power KTA50 G3 series engine

TPD2250H6.3 TECHNICAL DATA

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

SIVASA Doosan Series. SD250 Technical Data

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

60 Hz FEATURES. Exclusively from your Caterpillar dealer

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Model MP150 W W

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

Diesel generator set 6BT5.9 series engine

Voltage. kva kw kva kw

Rating Definitions and Conditions

130 KW / 165 KVA POWERED by

Rating Definitions and Conditions

Diesel generator set QSK78 series engine

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

PGDLS / / / / / / / / /

55 KW / 69 KVA POWERED by

PPU Diesel Power 50/60Hz Containerized Generator Set

Diesel generator set QSK60 series engine

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Transcription:

Super Silent, Superior Life! WPS45 S45/S /S- Technical Data Sheet

STANDARD SPECIFICATION General features: Composed of Perkins(UK) diesel engine and Stamford alternator Engine Charge alternator 12 V Single bearing alternator IP 23, insulation class H 40 radiator as standard, 45 is optional, water-cooled Skid and vibration isolators Dry type air filter, Main line circuit breaker Microprocessor control panel, Key start panel be optional 4 pole MCB, 12 V battery, rack and cable 8-hour operation base tank Special Integrated Steel Base tank and sprayed overall in gloss enamel pain Optional soundproof or weatherproof canopy, Industrial or residential silencer be optional Genset Main Technical cal Data Model Genset,50Hz at 1500 RPM, 3-PHASE, 400/230V Tank (L) Noise Level db(a) WPS45 200 98 WPS45S 245 73 kva kw ESP PRP ESP PRP Model PERKINS(UK) Engine, 1500RPM Bore/ stroke mm Cyl. Asp. Gov. 50 45 40 36 1103A-33TG1 105/127 3L TC M (1) Ambient reference conditions: 1,000 m bar, 27, 30% relative humidity. Rating according to ISO 3046 and 8528. (2) Available in the following voltages: 440/254-415/240V-400/230V-380/220V-220/127V-200-115V. (3) ESP: Standby Power Standby duty, operation under variable load, without over load. PRP: Prime Power-Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 hours. (4) M: Mechanical speed governor, E: Electronic speed governor. (5) NA: Naturally aspirated, TC: Turbocharged, TCA: Turbocharged and air-air aftercooled. TW: Water-cooled Turbocharged. Reliable Performance Voltage Regulation Voltage regulation maintained within ±0.5% as follow : Between 0.8 and 1.0 lagging and unity From no load to full load At speed droop variation up to 4.5% Frequency Adjustable Ratio Change load from 0-100%, within 1.0% (electric speed regulator), within 4.5% (mechanical speed regulator) Frequency Undulation Load from 0-100%, Frequency undulation within 0.25% No load wire volts max undulation ratio within 1.8% Three phrase balanced load in the order of 5% CRITERION Effect factor of telecom TIF better than 50 THF to BS4999 Part 40 better than 2% Electromagnetism In compliance with BS800 and VDE levels G and N ISO3046, ISO8528, BS4999, BS5514, BS5000PT99 AS1359, IEC34 UTE5100, VDE0530 ISO9001:2000, ISO14001

ENGINE SPECIFICATION Perkins (UK) Diesel Engine Building upon Perkins proven reputation within the power generation industry, the newly introduced 1100 Series range of Elect Ropak engines now fit even closer to the needs of their customers. Compact and Efficient Power The Perkins 1100 Series family was developed following an intensive period of customer research. The 3.3 and 4.4 liter engines feature new cylinder blocks which ensure bore roundness is maintained under the pressures of operation, as well as significantly reducing mechanical and combustion noise. Cleaner and Quieter Power The refined structure of the 1100C range leads to an exceptionally low noise signature. To meet environmental needs swirl conditioned air is delivered through the new cross-flow cylinder head, and burns cleanly with the high pressure fuel from an advanced technology rotary pump. Quality by Design Class A manufacturing improvements ensure that product reliability meets the high standards demanded by customers. Product design is focused on maintaining Perkins legendary reputation for durability. Technical Data Engine Model 1103A-33TG1 Engine Manufacturer /Brand Perkins (UK) Type and Cylinder 3L, 4-cycle Induction system TC Compression ratio 17.25:1 Cubic capacity L 3.3 Bore x Stroke mm 105 x 127 Test condition air temperature 25 Cross engine power KW 42.2 Mean piston speed m/s 6.03 Engine coolant flow l/min 125.5 Combustion Air Flow m³/min 2.9 Exhaust Gas Flow m³/min 7 Exhaust Gas Temperature 492 Starting System 12 Battery Voltage /Capacity 12V DC/80A/100 Fuel Consumption 100% L/hr 13.4 Fuel Consumption 75% L/hr / Fuel Consumption 50% L/hr / Governing Type M AC ALTERNATOR STAMFORD NEWAGE GENERATOR STAMFORD NEWAGE has a long history of producing high-quality reliable products for the power generation market. Their portfolio of high quality generator ends is recognized as an industry standard. Alternator Technical Data Stamford AC alternator Brushless, self exciting Class H insulation Standard degree of protection is IP23 Self regulating With fan cooling Resist humid grease AC excitation, rotating rectification tube Stator grease insulation covered Rotator and excitation high polymer Resist the corruption of oil and acid. Rotator balance is in accordance with BS5625 standard 12.5 High-quality lubrication sealed long-time bearing Rotator silicon steel close tight Alternator Technical Data Generator Model UCI224C Exciter Brushless Cooling Fan Cast alloy aluminum Bearing Single, double shielded Windings 100% copper Connection Type Reconnectable Insulation Type Class H Pitch 2/3 Amortisseur Winding Full A.V.R. Model SX460 Voltage Regulation NL - FL ± 0.5% Underspeed Protection Standard Overexcitation Protection IP23 Standards NEMA, IEC, IEEE, CSA, BS Phase Sequence A(U), B(V), C(W) TIF (1960 Weightings) <50 Excitation System Self-exciting, PMG optional In line with our policy of continuous product development, we reserve the right to make changes in model, technical specifications color, equipment and accessories without prior notice.

CONTROL SYSTEMS PLC-1F CONTROL SYSTEM --Controlled by Module GC-1F +B3 The Generator Controller GC-1F is a microprocessor- based control unit containing all necessary functions for protection and control of a diesel engine. Furthermore, it contains a three-phase AC voltage measuring circuit. The unit is equipped with an LCD display presenting all values and alarms. GC-1F is a compact all-in-one unit designed for the following applications: 1. Automatic engine start/stop 2. Engine protection 3. Breaker control 4. Generator protection 5. Automatic Mains Failure Optional applications: 6. CANbus J1939 engine communication PLC-1F system-s & M Model PLC-1F system-l & XL Model Description for Module GC-1F +B3: Display screen TFT LCD 7,4 in Graphic symbol messaging Clear text alarm messages 128 x 64 pixel backlight STN Power OK indicator Control keypad with display LEDs Directional keypad with activity LED Stop horn/alarm Configuration keypad Page up and down Start /Stop mode selection Open GEN circuit breaker Close GEN circuit breaker Open mains circuit breaker Close mains circuit breaker Set ready to output Close Generator pushbutton Configurable Area Manu mode selection Auto mode selection Activate the selected test in the entered time Lamp test: Activate all LEDs for 3 seconds Standard functions Shutdown Warning Engine Control Generator Monitoring Generator Protection Engine Monitoring Clear Text Display Loss of Speed Signal Alternator Under / Over Voltage Alternator Under/ Over Frequency Mains Under / Over Voltage Mains Under/ Over Frequency Under / Over Speed Low Oil Pressure High Engine Temperature Phase Sequence Electrical (Option) Earth Fault (Option) Alternator Under / Over Voltage Alternator Under/ Over Frequency Mains Under / Over Voltage Mains Under/ Over Frequency Under / Over Speed Low Oil Pressure Pre-Alarm High Engine Temperature Pre-Alarm High/Low Battery Voltage Over-current Periodic maintenance Page 4 of 6

PLC-702HC CONTROL SYSTEM Standard Control Function PLC 702-HC Module Manual Engine Control Module Low Oil Pressure High Engine Temperature Auxiliary Shutdown Overspeed Protection Protection hold-off timer Charge Failure warning PLC 702-HC Model Meters for Hz, Speed, Temp., Voltage, current Fuse Protection Circuit Breaker Emergency Stop Button Heavy Load Connector Ground Wires Weight and Dimensions WPS45 (Open set) Overall size (L*W*H), m 1.76 088 1.36 Weight (kg):810 WPS45S (Soundproof set)) Overall size (L*W*H), m 2.40 1.00 1.52 Weight (kg):1300 *The weights are approximate. Page 5 of 6

OPTIONAL FEATURES Fuel System Options Low fuel level shutdown Engine Oil Heater Manual Sump Oil Drain Pump Exhaust Options Exhaust Silencer-industrial(9dB),In-Line Exhaust Silencer-Residential (25dB),In-line Flexible and fixing kit for industrial silencer Flexible and fixing kit for Residential silence Switchgear Circuit Breaker MCCB & ACB Mains auto-charger Auto Transfer Switch Canopy Mobile Sets /Trailer Weatherproof/Acoustic Enclosures Voltage Connections 277/480V,3 Phase 254/440V,3 Phase 240/416V,3 Phase 230/400V,3 Phase 220/380V,3 Phase 127/220V,3 Phase 115/200V,3 Phase 110/190V,3 Phase Control Panels Earth Fault Relay Remote Monitor Interface Protection for Alarm Module & Auxiliary Relay Parallel control panels Miscellaneous Options Coolant heater-240/120v Battery Charger 110-277V,3A PCC2100 with barograph Earth Fault Relay Packing-Export Box Air Switch BGC Paralleling Control system ATS Trailer set Current Generation ltd phone + 64 03 5480344 Cell +64 027 2027005 postal address Po Box 458 Motueka warehouse address(delivery address) 7 Kotua PL Stoke Nelson New Zealand 7011 www.currentgeneration.co.nz Local Distributor