Prime* Voltage kva kw kva 380-415 180 144 200 Standby* kw 160 Ampere 251 Prime Rating Standby Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model can supply 10% overload power for a period of 1 hour in 12 hours operation as it is defined in ISO 3046. Applicable for supplying continuous power ar variable load in the event of a utility power failure and overload is not allowed as it is defined in ISO 8528-3. Standard Generator Features AMF, Automatic mains failure unit Heavy duty type, 6 cylinder, water cooled engine 50 C tropical type radiator Starter motor Lead acid battery Charging alternator Battery charge redressor Heavy duty, brushless type alternator Base frame with anti-vibration units Industrial type silencers Flexible exhaust compensator Block water heater unit Control panel with digital-automatic main control module Fan, fan drive, charging alternator drive and all rotating parts covered Radiator matrix covered by metal mesh against the mechanical damages Fabricated and welded steel base frame Anti-vibration mountings Engine and alternator manufacturer test reports Factory load, performance and function tests Optional Features Cable drum Working accesories compartment Light tower Protection circuit breaker Air start Remote type radiator External type fuel tank Automatic fuel transfer system Residential silencer Dimensions & Weight Sound Attenuated Dry Weigt Length Width kg Height Tank Capacity L Technical Data Sheet 120824 - Page1
Engine Technical Data Cooling System Manufacturer PERKINS Type Tropical, heavy duty type Model 1106C-E66TAG4 Ambient temperature, C 50 Type 4 cycle, water-cooled Engine&Radiator coolant capacity 21 Number of cylinders 6 Pressure cap setting, kpa 35 Cylinder arrangement Vertical in-line 27" belt driven pusher fan and guards Displacement, Liters 6,6 Radiator incorporating with air to air charge cooler and fuel cooler Bore X Stroke, 105 X 127 Water pump Compression Ratio 16.2:1 Combustion System Direct injection Aspiration Turbocharged, air to air charge cooled Rotation Anti-clockwise, viewed on flywheel Lubrication System Gross engine power, kwb 180,4 Fan Power, kwm 7 Type Pressurized BMEP gross, bar 20,55 Capacity, Liters 28,3 Combustion air flow, m³ / min 11,7 Lub oil pressure (min), kpa 430 Exhaust gas temp.(after turbo), C 499 Flat bottomed isolated aluminium sump Exhaust gas flow (after turbo),m³ / m31 Oil filter Mean piston speed, m / s 6,8 Fuel System Fuel Consumption Type of injection system Electronic liters per hour %110 Load Fuel pump CR200 %100 Load Max. fuel flow 1,5 l/min %75 Load Max. static pressure head 600 kpa %50 Load Tolerance on fuel consumption 3% Electronic governing confirms to Class G3 ISO 8528-5 grams per kwh %110 Load Fuel Filter %100 Load %75 Load %50 Load 44 L 40,2 L 31 L 20,5 L 204,9 g/kwh 206,9 g/kwh 212,7 g/kwh 211,6 g/kwh Electrical System Alternator 12 Volts Starter motor (DC) 12 Volts Standby kw Prime kw Model Starter motor power 3 kw Gross Net Gross Net 12 Volt 100 Amper alternator with DC output 1106C-E66TAG4 180,4 175,5 163,3 158,4 Technical Data Sheet 120824 - Page2
Alternator Technical Data Optional Equipment Manufacturer STAMFORD Optional Permanent Magnet Generator (PMG) provides an isolated Model UCI274G power supply to the excitation control system Type 4-Poles, Rotating Field, Brushless Anti Condensation Heaters Standby power at rated voltage, kva200 Air Filters Efficiency, % 92,2 Temperature Indication RTD s Power factor 0.8 Winding Protection Thermistors Phase 3 Quadrature Droop kit for Parallel Operation Frequency, Hz 50 SX440 AVR with 1% Regulation and 2 Phase Sensing Speed, Rpm 1500 SX421 AVR with 3 Phase Sensing and improved Regulation 0.5% Voltage, V 380/415 MX341 (PMG) 1% Regulation with 2 Phase Sensing Excitation Self excited MX321 (PMG) with 3 Phase Sensing and improved Regulation 0.5% Stator windings 2/3 Pitch factor Regulation AVR, Auto Voltage Regulator Terminals&Terminal Box Voltage Regulator SX460 Voltage Regulation, % ± 1 Standard generators feature a main stator with 6 ends brought out to R.F.I Suppression BS EN 61000-6-2,BS EN 61000-6-4 the terminals, which are mounted on the frame at the non-drive end VDE0875G, VDE 0875N of the generator. A sheet steel terminal box contains the AVR and Waveform distortion No Load <1.5% Non distorting balanced provides ample space for the customers wiring and gland Rotor Dynamic balanced arrangements.it has removable panels for easy access. Overspeed, Rpm 2250 Short circuit current < 300% Shaft&Keys TIF Less than 50 Insultion class H All generator rotors are dynamically balanced to better than BS6861 Construction Single bearing, direct coupled :Part 1 Grade 2.5 for minimum vibration in operation. Two bearing Coupling Flexible generators are balanced with a half key. Stator winding Double layer concentric Connection WYE Insulation / Impregnation Protection class IP23 Cooling air volume,m³ / sec 0.514 The insulation system is class 'H' All wound components are impregnated with materials and Winding&Electrical Performance processes designed specifically to provide the high build required for static windings and the high mechanical strength required for All generator stators are wound to 2/3 pitch.this eliminates triplen rotating components. harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads.the 2/3 pitch Standards design avoid sexcessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains.a fully Newage Stamford industrial generators meet the requirements of BS connected damper winding reduces oscillations during paralelling. EN 60034 and the relevent section of other international standards such as This winding, with the 2/3 pitch and carefully selected pole and BS5000,VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359 tooth designs, ensures very low waveform distortion. Other standards and certifications can be considered on request Quaility Assurance Standby Prime Model Generators are manufactured using production procedures having a quaility kva kw kva kw assurance level to BS EN ISO 9001. UCI274G 200 160 182 146 Technical Data Sheet 120824 - Page3
Deepsea 7320 Control System Description Deepsea 7320 is an Auto Mains(Utility) Failure Control module. The module is used to monitor a mains supply and automaticlly start a standby generator set. The module can also monitor an extensive number of engine parameters and it can display warnings, shutdown and engine status information on the back-lit LCD screen, illuminated LEDs, remote PC and via SMS text alerts. Selected timers and alarms can be altered by the user from the front panel. Alterations to the system are made using the 810 interface and a PC and it also provides real time diagnostic facilities Specification DC SUPPLY Continuous Voltage Rating: 8 V to 35 V Maximum Operating Current: 340 ma at 12 V, 160 ma at 24 V Maximum Standby Current: 160 ma at 12 V, 80 ma at 24 V Charge Fail/Excitation Range: 0 V to 35 V MAINS(UTILITY) & GENERATOR Voltage Range: 15 V - 333 V AC (L-N) Frequency Range: 3,5 Hz to 75 Hz OUTPUTS Output A (Fuel): Output B (Start): Output C & D : Input Functions display on LCD 15 A DC at supply voltage 15 A DC at supply voltage 8 A 250 V (Volt free) Generator Volts Volts L1-N, L2-N, L3-N Generator Volts Volts L1-L2, L2-L3, L3-L1 Generator Amps Amps L1, L2, L3 Generator Frequency Hz Mains Volts Volts L1-N, L2-N, L3-N Mains Volts Volts L1-L2, L2-L3, L3-L1 Mains Frequency Hz Engine Speed RPM Plant Battery Volts Volts Engine Hours Run Hour Generator total power kva L1, L2, L3,total Generator total power kw L1, L2, L3,total Generator power factor Cosφ L1, L2, L3,total Features 4-Line back-lit LCD text display and five key menu navigation LED and LCD alarm indication 9 configurable inputs and 8 configurable outputs Configurable timers, alarms and event log (250) Fuel usage monitor and low fuel alarms Charge alternator failure alarm Manual speed and manual fuel pump control Engine exerciser and ''Protections disabled'' feature kw overload protection Power monitoring ( kw, h, kv Ar, kv A h, kv Ar h) Load switching (load shedding and duy load outputs) Automatic load transfer and unbalanced load protection Independent Earth Fault trip Support for up to three remote display units and USB connectivity Configurable display languages Remote SCADA monitoring User selectable RS232 and RS485 counications SMS messaging ( external modem required) Additional display screens to help with modem diagnostics Alarm Channels Under/over generator voltage Over-current Under/over generator frequency Under/over speed Charge fail Emergency stop Low oil pressure High engine temperature Fail to start Low/high DC battery voltage Reverse power Generator phase rotation error Generator short-circuit protection Loss of speed sensing signal Mains out of limits Optional Input Functions Engine Oil pressure Fuel level Engine Temperature kpa % C Technical Data Sheet 120824 - Page4
Model Codes and General Information Kunz Diesel Generator KZ M 180 P S Alternator Make-Stamford Engine Make-Perkins Prime Rating - kva Mobile type KUNZ diesel generator Perkins 1100 Series Diesel Engine Newage / Stamford Alternator 1106C-E66 T A G 4 UC I 27 4 G Power level Genset engine Air to air charge cooled Turbo charged Electronic 6,6 liters Core Length Number of poles Shaft Height in cm Industrial Generator type 1100 Series, 6 cylinder Technical Data Sheet 120824 - Page5