MFM220 & MFM220DC Plastic-Bodied Magmeter

Similar documents
MFM300 Plastic-Bodied Magmeter

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

WMP-Series. Plastic-Bodied Magmeter Instructions ISO. 2 inch. Precision Flow Measurement. An ONICON Brand 9001:2008 PROUDLY MADE IN THE USA.

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

AG2000 IRRIGATION MAGMETER INSTRUCTIONS

WMX-SERIES Flanged Magmeter

imag 4700 SERIES FLANGED MAGMETER

ISTEC MAGNETIC METERS

Positive Displacement Flowmeters

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

PE202. Low Flow Magmeter Instructions. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

AG2000 Irrigation Magmeter

TABLE OF CONTENTS Service Information 2 Quick Start Instructions 4-5 Introduction 6 Specifications 6 Controls and Terminology

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

List of Contents. Agrimag User Guide 1 V V

Instructions EM 101 Low Flow Electromagnetic Flow Meters

TURBINE METERS - WP Series

Propeller. Flowmeter. Technology. For the Real World.

FLOW METERS FOR MINING

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Magnetic Inductive Flowmeter EP / UMF2 (B)

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

Appendix. Clearance. Skewed profiles. Application Schematics

Hydro-Flow Model 2300 Installation and Operation Guide B

TX101/201 Insertion Turbine Instructions

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

TX 115/215 Hot-tap Insertion Turbine Instructions

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

RUN ACCUM. TOTAL STOP BAT LOW HIGH

M SERIES Multi-Jet Cold Water Meter

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

TX115/215 Hot-tap Insertion Turbine Instructions

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

digital flow meters BW Digi-Meter F-1000

TX101/201 Insertion Turbine Instructions

유량계전문제조업체. Electro Magnetic FLOWMETER

Magnetic-inductive flow meter for hazardous areas

3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Vortex Eggs Delta Flowmeter

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

Hydro-Flow Model 3100

MODEL 901 OPERATING INSTRUCTIONS

MODEL TRIMMER. Operating and Maintenance Instructions. Item and

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

DW PADDLE-BELLOWS FLOWMETER & SWITCH

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

TYPE MP OSCILLATING PISTON FLOWMETER

F-2700 SERIES INSERTION VORTEX FLOW METER

SeaMetrics Flow Meters and Flow Computers

Operating Manual Model- P282 Digiflow Controller

TX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX101/201 TX115/215 ISO 9001:2008 CERTIFIED COMPANY

WALCHEM LINEAR POLARIZATION RESISTANCE CORROSION SENSORS Instruction Manual

MULTI-JET WATER METERS

Model TUR-200D Turbine Flowmeter

Ultra Mag SUBMITTAL PACKAGE

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

DW PADDLE-BELLOWS FLOWMETER & SWITCH

RCM - Direct Reading Flowmeters

INSTRUMENTATION & CONTROL

Model Q45H/ Residual Chlorine Monitor...

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Rosemount 8750WB Magnetic Flowmeter System

Sparling Propeller Meters

F-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

OPERATING AND MAINTENANCE MANUAL BATCH PRESSURE FILTER 3 GALLON CAPACITY

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

Propeller Meters. Flow measurement solutions for water and wastewater

DW PADDLE-BELLOWS FLOWMETER & SWITCH

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

Nautilus Gallon Per Day Modular Watermakers.

Field IT Electro-Magnetic Flowmeters Sensors

Product Instructions. Mixing Station. Features. Specifications. Materials

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

F-2700 SERIES INSERTION VORTEX FLOW METER

Transcription:

APPLICATIONS Usage monitoring, such as: Industrial wastewater discharge monitoring Cooling tower deduct metering Heap leach mining discharge monitoring Well monitoring Turf and landscape water monitoring Agriculture liquid monitoring FEATURES Simple as a mechanical meter No moving parts Minimal straight pipe required Battery powered Built-in rate & total indicator Corrosion resistant MFM220 & MFM220DC Plastic-Bodied Magmeter * Will not read petroleum based liquids. The 2" Flow Meter Series are a full-bore, plastic-bodied electromagnetic flow meter designed for flow and usage monitoring applications in 2" pipe. The polypropylene flow tube offers corrosion resistance to a wide range of chemicals. Its light weight and clamp flanges allow it to be easily installed or removed from the pipe for inspection. There are multiple configurations. With no moving parts, the magmeter permits unobstructed flow, minimizing flow disturbances. The 2" Meter Series can be used in piping configurations where there is little space between the meter and valve. The 2" Meter Series, like other magmeters, are resistant to wear from debris. Since there are no bearings or propeller to wear out, downtime and maintenance are kept to a minimum. Because there are no mechanical parts in the flow stream, the meter tolerates high flows without damage. Please note that flow does not automatically turn the meter on. The hinged, polyethylene cover protects from dust and UV rays, while permitting easy access to the LCD flow rate and total display. The electronics housing is made of rugged powder-coated die-cast aluminum. Flow rate and total can be displayed in a variety of units, customerselected and factory-set. The 2" Meter Series are used for tracking flow rates and total flow in usage monitoring applications. These would include wells, industrial wastewater, leach mining discharge, cooling tower deduct metering, turf and landscape applications, and other water reclamation operations. When changing the batteries, the 2" is designed to retain the internal settings and flow total. The DC flow meters are externally powered via a 5-pin connector cable (20ft/6m) which also provides pulse output for use with a variety of displays and controls for remote reading, data logging, pulse-to-analog conversion, and telemetry applications. Unobstructed Flow 150 Banjo Drive Crawfordsville, IN 47933 ph: 765-362-7367 fax: 800-458-0232 www.banjocorp.com The standard flow meters are a battery-operated unit for use when pulse output is not required. The batteries are user replaceable with an approximate 1-year life under continuous use, or more depending on the duty cycle. The flow meters shut off after 15 minutes of inactivity to preserve battery life. Manual# FMM2000

INSTRUCTIONS 1. When placing the flowmeter in line, it is important to rotate the flowmeter so that it is approximately at a 45-degree angle. (See figure 1) This will improve performance of the flow meter. The flow meter can be placed vertical as long as flow is sufficient to fill the pipe. 2. There are 3 photoeyes located on the face of the flow meter. Note: These are not buttons so you will not push them, instead, to activate you must hold your finger over the photoeye for 2-4 seconds. To reset the running total you must hold your finger over both the batch reset and the batch/total photoeyes. If you would like liters rather than gallons, you will need to hold your finger over the first and third photoeyes at the same time. (See figure 2) 3. There are six (6) AA batteries located inside the flow meter. To replace the batteries, simply remove the four cover bolts and gently remove the top cover. Replace batteries and fasten cover back in place. Be careful not to pinch any wires when assembling the cover. It is a good idea to change the batteries yearly. 6. The EP is an error message meaning that the system is idle and there is no fluid traveling through it at that time. 7. It is recommended to have at least 20 inches of straight pipe before the flow meter and at least 20 inches after. 8. The cover can be rotated. To rotate cover 90, remove the 4 cover bolts and carefully rotate the cover to the desired position. Take note not to pull or pinch any of the connecting wires. To rotate the cover 180, remove the 4 cover bolts, the 6 AA batteries and the 2 screws that hold the battery holder in place. Then rotate the battery holder and the cover together to the desired location. Take note not to pull or pinch any of the connecting wires. photoeye 4. The flow rate of the meter is designed to have an unlimited flow, meaning that the meter will read as much flow as one can push though a 2" full port coupling. However, the accuracy of the meter decreases as the meter reaches flows under 6 GPM. From 6 to 300 GPM the meter is within 2-3% accuracy. 5. Its advisable to thoroughly clean the meter and the electrodes at least once a year. This can be done by gently rubbing the electrodes with a piece of emery cloth. FIGURE 1 FIGURE 2 2

FEATURES DIMENSIONS Polyethylene protective cover 4 5 45/32 / 32" LCD rate and total indicator 6 Powder-coated die cast-aluminum electronics housing 2 3¾" 33/4 51/2 5½" 2 1 21/32 / 32" Corrosion-resistant glass-filled polypropylene body Lightweight for easy handling 316 SS electrodes 3 Clamping flanges for ease of installation

SPECIFICATIONS* SPECIFICATIONS Pipe Size 2" Full Port Fittings Flange Clamps Pressure 150 PSI or 10.3 bar working pressure @ 70 F Operating Temperature Range 10 to 130 F (-12 to 54 C) Accuracy +/-1% of reading from 100% to 10% of full scale +/-3% of reading from 10% to 10% of full scale to cut off => 2% to 10% Flow Range Minimum 6 gallons per minute (22.7 liters per second) Maximum 300 gallons per minute (1135.6 liters per second) Materials Body Glass-filled polypropylene Electrodes 316 stainless steel Electronics Housing Die cast aluminum, powder-coated Display Cover Polyethylene Display Rate Digits 6 Units Gallons/Minute Liters/Minute Power 6 AA alkaline cells, replaceable Life: 1 year with meter in use; 3 years dry 10-30 Vdc @ 60 ma max (15 ma average) Note: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation. Pulse Output Signal Current sinking pulse, opto isolate, 32 Vdc max at 10 ma max Standard Pulse Rate 1 unit/pulse out, pulse width of 10 ms depending on unit selection High Frequency 30 Pulse per unit, pulse width 1.1 ms, min-max frequency, 3-150 HZ Empty Pipe Detection Hardware/software, conductivity-based Conductivity >20 microsiemens Environmental NEMA 4X standard; -40 to 176 F (-40 to 80 C) storage Electrical Connection 5 pin male circular connector, mates to industry standard cable (20ft/6m) * Specifications subject to change Please consult our website for current data (www.banjocorp.com) 4

INSTALLATION Piping Conditions Installing the meter with a length of straight pipe at least two times the diameter upstream and one diameters downstream is highly recommended. Some piping conditions require more than this. See chart for recommendations. If hose is used, use smooth bore hose. Follow the diagram below to make the connections. Step 1. Position gasket at either end Step 2. Place adapter against gasket, open screw clamps to clear flanges 5 Step 3. Place screw clamps over both adapter and meter flanges and tighten screws

POSITION This is an all position meter which can be installed either vertically or horizontally, register up, down or angled. However, entrained air or solids may make some positions preferable to others. See the position diagram for guidance. Electrode moved from top by rotating meter Intermittent air bubbles miss electrode Intermittent air bubbles pass over electrode Recommended: May prevent sediment or bubble problems Electrodes free from sediment build-up Less Ideal: Air bubbles and sediment on the electrodes can affect accuracy Possible sediment build-up 6

STRAIGHT AND FULL PIPE RECOMMENDATIONS It is recommended to have at least 20 inches of straight pipe before the flow meter and at least 20 inches after. 10x 10x X = Diameter ELECTRICAL CONNECTIONS, CABLE CONNECTIONS & OPERATION ELECTRICAL CONNECTIONS A connector is provided on the outside of the flow meters. To connect to the meter, plug the cable in and hand tighten the retaining threads. Follow the diagram to make connections. If you are using the pulse output, connect power first and determine that the meter is working properly by observing the display, then connect the pulse output. CABLE CONNECTIONS OPERATION - GROUNDING For best performance, especially in noisy environments, the gray ground wire and the bare drain wire should be connected together and to a good earth ground as close to the meter as possible. Metal pipe and fittings in contact with the fluid, should also be bonded to the same earth ground with corrosion-resistant connections. 7

Display The display reads flow rate and accumulated total, in the units for which it was ordered. The top line is total, the bottom line is rate, and indicators give the units (ac-ft, GPM for instance.) Empty or partially-full pipe is automatically detected and is indicated by a reading of -EP-. Battery Estimated battery life is approximately one year. Results may vary depending on the application. On the battery-powered 2" Series there are a lowbattery indicator ( lo bat ) when the battery voltage drops below a certain point. Batteries should be changed within four weeks of the appearance of this indicator. MAINTENANCE, REPAIR AND TROUBLE SHOOTING MAINTENANCE AND REPAIR There are no user-serviceable parts in the 2" Series meters except the batteries. Battery Replacement When the Lo Batt indicator appears, the batteries should be changed. Six alkaline AA cells are required. To change the batteries, first remove the four screws which hold the top cover in place. Be careful not to lose the washers. Move the top cover to one side and remove the foam retainer which covers the battery tray. Remove the old batteries and replace them with fresh ones, taking care to follow the polarity indicators in the battery tray. Replace the foam retainer, then put the top cover back in place. Put the four screws with washers back and tighten them firmly. TROUBLE SHOOTING PROBLEM PROBABLE CAUSE TRY Blank Display Batteries dead or misinstalled Check polarity, replace batteries Reading -EP- Empty or partly filled pipe Excessive air pockets or foaming Rearrange piping to ensure full pipe Flow but no flow rate reading Heavily coated electrodes Remove meter and wipe electrodes 150 Banjo Drive Crawfordsville, IN 47933 ph: 765-362-7367 fax: 800-458-0232 www.banjocorp.com 8 Scan this QR code to watch our video on Flow Meters!

APPLICATIONS Usage monitoring, such as: Industrial wastewater discharge monitoring Cooling tower deduct metering Heap leach mining discharge monitoring Well monitoring Turf and landscape water monitoring Agriculture liquid monitoring FEATURES Simple as a mechanical meter No moving parts Minimal straight pipe required Battery powered Built-in rate & total indicator Corrosion resistant MFM220 & MFM220DC Plastic-Bodied Magmeter * Will not read petroleum based liquids. The 2" Flow Meter Series are a full-bore, plastic-bodied electromagnetic flow meter designed for flow and usage monitoring applications in 2" pipe. The polypropylene flow tube offers corrosion resistance to a wide range of chemicals. Its light weight and clamp flanges allow it to be easily installed or removed from the pipe for inspection. There are multiple configurations. With no moving parts, the magmeter permits unobstructed flow, minimizing flow disturbances. The 2" Meter Series can be used in piping configurations where there is little space between the meter and valve. The 2" Meter Series, like other magmeters, are resistant to wear from debris. Since there are no bearings or propeller to wear out, downtime and maintenance are kept to a minimum. Because there are no mechanical parts in the flow stream, the meter tolerates high flows without damage. Please note that flow does not automatically turn the meter on. The hinged, polyethylene cover protects from dust and UV rays, while permitting easy access to the LCD flow rate and total display. The electronics housing is made of rugged powder-coated die-cast aluminum. Flow rate and total can be displayed in a variety of units, customerselected and factory-set. The 2" Meter Series are used for tracking flow rates and total flow in usage monitoring applications. These would include wells, industrial wastewater, leach mining discharge, cooling tower deduct metering, turf and landscape applications, and other water reclamation operations. When changing the batteries, the 2" is designed to retain the internal settings and flow total. The DC flow meters are externally powered via a 5-pin connector cable (20ft/6m) which also provides pulse output for use with a variety of displays and controls for remote reading, data logging, pulse-to-analog conversion, and telemetry applications. Unobstructed Flow 150 Banjo Drive Crawfordsville, IN 47933 ph: 765-362-7367 fax: 800-458-0232 www.banjocorp.com The standard flow meters are a battery-operated unit for use when pulse output is not required. The batteries are user replaceable with an approximate 1-year life under continuous use, or more depending on the duty cycle. The flow meters shut off after 15 minutes of inactivity to preserve battery life. Manual# FMM2000

INSTRUCTIONS 1. When placing the flowmeter in line, it is important to rotate the flowmeter so that it is approximately at a 45-degree angle. (See figure 1) This will improve performance of the flow meter. The flow meter can be placed vertical as long as flow is sufficient to fill the pipe. 2. There are 3 photoeyes located on the face of the flow meter. Note: These are not buttons so you will not push them, instead, to activate you must hold your finger over the photoeye for 2-4 seconds. To reset the running total you must hold your finger over both the batch reset and the batch/total photoeyes. If you would like liters rather than gallons, you will need to hold your finger over the first and third photoeyes at the same time. (See figure 2) 3. There are six (6) AA batteries located inside the flow meter. To replace the batteries, simply remove the four cover bolts and gently remove the top cover. Replace batteries and fasten cover back in place. Be careful not to pinch any wires when assembling the cover. It is a good idea to change the batteries yearly. 6. The EP is an error message meaning that the system is idle and there is no fluid traveling through it at that time. 7. It is recommended to have at least 20 inches of straight pipe before the flow meter and at least 20 inches after. 8. The cover can be rotated. To rotate cover 90, remove the 4 cover bolts and carefully rotate the cover to the desired position. Take note not to pull or pinch any of the connecting wires. To rotate the cover 180, remove the 4 cover bolts, the 6 AA batteries and the 2 screws that hold the battery holder in place. Then rotate the battery holder and the cover together to the desired location. Take note not to pull or pinch any of the connecting wires. photoeye 4. The flow rate of the meter is designed to have an unlimited flow, meaning that the meter will read as much flow as one can push though a 2" full port coupling. However, the accuracy of the meter decreases as the meter reaches flows under 6 GPM. From 6 to 300 GPM the meter is within 2-3% accuracy. 5. Its advisable to thoroughly clean the meter and the electrodes at least once a year. This can be done by gently rubbing the electrodes with a piece of emery cloth. FIGURE 1 FIGURE 2 2

STRAIGHT AND FULL PIPE RECOMMENDATIONS It is recommended to have at least 20 inches of straight pipe before the flow meter and at least 20 inches after. 10x 10x X = Diameter ELECTRICAL CONNECTIONS, CABLE CONNECTIONS & OPERATION ELECTRICAL CONNECTIONS A connector is provided on the outside of the flow meters. To connect to the meter, plug the cable in and hand tighten the retaining threads. Follow the diagram to make connections. If you are using the pulse output, connect power first and determine that the meter is working properly by observing the display, then connect the pulse output. CABLE CONNECTIONS OPERATION - GROUNDING For best performance, especially in noisy environments, the gray ground wire and the bare drain wire should be connected together and to a good earth ground as close to the meter as possible. Metal pipe and fittings in contact with the fluid, should also be bonded to the same earth ground with corrosion-resistant connections. 7

SPECIFICATIONS* SPECIFICATIONS Pipe Size 2" Full Port Fittings Flange Clamps Pressure 150 PSI or 10.3 bar working pressure @ 70 F Operating Temperature Range 10 to 130 F (-12 to 54 C) Accuracy +/-1% of reading from 100% to 10% of full scale +/-3% of reading from 10% to 10% of full scale to cut off => 2% to 10% Flow Range Minimum 6 gallons per minute (22.7 liters per second) Maximum 300 gallons per minute (1135.6 liters per second) Materials Body Glass-filled polypropylene Electrodes 316 stainless steel Electronics Housing Die cast aluminum, powder-coated Display Cover Polyethylene Display Rate Digits 6 Units Gallons/Minute Liters/Minute Power 6 AA alkaline cells, replaceable Life: 1 year with meter in use; 3 years dry 10-30 Vdc @ 60 ma max (15 ma average) Note: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation. Pulse Output Signal Current sinking pulse, opto isolate, 32 Vdc max at 10 ma max Standard Pulse Rate 1 unit/pulse out, pulse width of 10 ms depending on unit selection High Frequency 30 Pulse per unit, pulse width 1.1 ms, min-max frequency, 3-150 HZ Empty Pipe Detection Hardware/software, conductivity-based Conductivity >20 microsiemens Environmental NEMA 4X standard; -40 to 176 F (-40 to 80 C) storage Electrical Connection 5 pin male circular connector, mates to industry standard cable (20ft/6m) * Specifications subject to change Please consult our website for current data (www.banjocorp.com) 4

INSTALLATION Piping Conditions Installing the meter with a length of straight pipe at least two times the diameter upstream and one diameters downstream is highly recommended. Some piping conditions require more than this. See chart for recommendations. If hose is used, use smooth bore hose. Follow the diagram below to make the connections. Step 1. Position gasket at either end Step 2. Place adapter against gasket, open screw clamps to clear flanges 5 Step 3. Place screw clamps over both adapter and meter flanges and tighten screws

FEATURES DIMENSIONS Polyethylene protective cover 4 5 45/32 / 32" LCD rate and total indicator 6 Powder-coated die cast-aluminum electronics housing 2 3¾" 33/4 51/2 5½" 2 1 21/32 / 32" Corrosion-resistant glass-filled polypropylene body Lightweight for easy handling 316 SS electrodes 3 Clamping flanges for ease of installation

POSITION This is an all position meter which can be installed either vertically or horizontally, register up, down or angled. However, entrained air or solids may make some positions preferable to others. See the position diagram for guidance. Electrode moved from top by rotating meter Intermittent air bubbles miss electrode Intermittent air bubbles pass over electrode Recommended: May prevent sediment or bubble problems Electrodes free from sediment build-up Less Ideal: Air bubbles and sediment on the electrodes can affect accuracy Possible sediment build-up 6