O i l L e v e l D i p s t i c k s C4.0410 C4.0412 C4.0421 C4.0431 C4.0450 C4.0464 With mounting bolts Bolt thread up to M10 Dipstick length up to 25.2 inch 70.10-2us
D e s c r i p t i o n Application Controlling the oil level in hydraulic oil or lubricant reservoirs Construction and function ARGO-HYTOS oil level dipsticks are robust semicircular metal rods with an O-ring seal. A mounting bolt with a suitable hole is supplied with each dipstick. Dipsticks are available in various lengths, with various markings, and with various mounting bolts (see selection chart). Special features The robust material withstands even the most severe operating conditions The integral O-ring provides a 100% tight seal A suitable dipstick mounting bolt can also replace one of the mounting bolts of an in-tank return or suction filter Mounting The bolt supplied with the oil level dipstick is installed either in a separate threaded hole or in an already existing mounting hole for an in-tank filter. This eliminates the need of an extra mounting hole. If used as a filter mounting bolt, care should be taken to provide a proper seal between the tank, the filter and the mounting bolt. S e l e c t i o n C h a r t Part No. Dipstick dimension L1 Dipstick dimension L2 Dipstick dimension L3 Mounting bolt Grade Remarks inch inch inch 1 2 3 4 5 7 8 C4.0410-00330 3.94 - - SV.2810.05 8.8 - C4.0410-01330 3.94 3.74 2.52 SV.2810.05 8.8 - C4.0412-00330 4.72 - - SV.2810.05 8.8 - C4.0412-03330 4.72 3.82 1.85 SV.2810.05 8.8 - C4.0412-04330 4.72 3.94 2.95 SV.2810.05 8.8 - C4.0421-00330 8.27 - - SV.2810.05 8.8 - C4.0421-04330 8.27 4.65 3.46 SV.2810.05 8.8 - C4.0421-06330 8.27 2.80 1.81 SV.2810.05 8.8 - C4.0431-00330 12.20 - - SV.2810.05 8.8 - C4.0431-01330 12.20 7.48 6.30 SV.2810.05 8.8 - C4.0450-00330 19.68 - - SV.2810.05 8.8 - C4.0464-00330 25.20 - - SV.2810.05 8.8 - C4.0464-01330 25.20 24.80 3.54 SV.2810.05 8.8 - Remarks: The dipsticks listed in the chart are standard dipsticks. If modifications are required, e.g. for the use in pressurized tanks, we kindly ask for your request. 216
D i m e n s i o n s Dipstick with bolt G Dipstick øb H O-ring ARGO-HYTOS Part No. N007.0043/2 (included in basic equipment) ø A E A/F C Bolt F L3 D L2 L1 Level marks D i m e n s i o n s Bolt A B C D E F G H A/F SV.2810.05 0.39 0.15 0.18 M10 0.28 1.18 0.39 1.54 17 mm 217
C h a ra c t e r i s t i c s Operating pressure Max. 14.5 psi (abs.) (Not suitable for use in pressurized hydraulic oil tanks) Connection Threaded ports according to ISO 228 or DIN 13. Sizes see section Dimensions (other port threads on request) Materials Dipsticks: Bolts: Seals: Steel, zinc plated Steel, zinc plated NBR (Viton on request) Mounting position Preferably in vertical position, above the oil level Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info-sheet 00.20) Temperature range - 22 F... + 212 F (temporary + 257 F) Ambient temperature range - 22 F... + 176 F (temporary + 212 F) Q u a l i t y A s s u ra n c e Quality management according to DIN EN ISO 9001 Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Our engineers will be glad to assist you with questions concerning filter application, selection, and cleanliness class of the filtered medium attainable under practical operating conditions. Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. We produce fluid power solutions ARGO-HYTOS Inc. P.O. Box 28 Bowling Green, OH 43402 USA Tel: +1-419-353-6070 Fax: +1-419-354-3496 info.us@argo-hytos.com www.argo-hytos.com Subject to change 9107223-us 0206 218
O i l L e v e l G a u g e s C5.3511 C5.3516 C5.3529 With thermometer Indication range up to 7.64 inch Temperature indication up to 180 F 70.50-3us
D e s c r i p t i o n Application Indicates the oil level and the oil temperature in hydraulic oil or lubricant reservoirs. Construction and function ARGO-HYTOS oil level gauges consist of a robust metal housing equipped with a sight level tube and built-in thermometer. The fluid enters the thermometer chamber through the mounting bolts, which are hollow. O-rings provide a seal against the housing and the reservoir wall. Special features The robust metal housing is designed to withstand even the most severe operating conditions The integrated scale shows the oil temperature in C and F Mounting The hollow screws and the locking nuts supplied with the gauge, enable installation on the reservoir wall by using two bores. The locking nuts serve the purpose of retightening the bolts from the outside (tightening torque: 8 Nm). Threaded holes are required instead of smooth bore holes if the wall of the reservoir is more than 0.31 inch thick. S e l e c t i o n C h a r t Part No. Oil level indicating range E Total height B Temperature indicating range Temperature indicating range Mounting bolts inch inch C F lbs 1 2 3 4 5 6 7 8 Weight Remarks C5.3511-50 1.30 4.25 +20... +80 80... 180 M10 0.40 - C5.3516-50 2.91 6.26-10... +80 20...180 M12 0.53 - C5.3529-50 7.64 11.22-10... +80 20... 180 M12 0.71 - Remarks: The gauges listed in the chart are standard gauges. If modifications are required, we kindly ask for your request. 220
D i m e n s i o n s Black mark for maximum oil level Red mark for minimum oil level At the housing C5.3529-50 the field of view is split in half. M e a s u re m e n t s Type A B C D E F G H I K 1 K 2 L max. A/F A/F C5.3511-50 2.99 4.23 1.36 0.89 1.30 0.63 0.71 1.14 0.31 17 mm 17 mm M10 C5.3516-50 5.0 6.26 1.36 1.04 2.91 0.63 0.71 1.14 0.31 18 mm 17 mm M12 C5.3529-50 10.0 11.22 1.36 1.10 7.64 0.63 0.71 1.14 0.31 18 mm 17 mm M12 221
C h a ra c t e r i s t i c s Operating pressure Max. 29 psi (abs.) Connection Threaded ports according to DIN 13. Sizes see Selection Chart, column 6 and section Dimensions Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info-sheet 00.20) Temperature range - 4 F... + 180 F Materials Housing: Sight level tube: Skalenplatte: Thermometer: Bolts: Seals: Steel, powder coated, black Polyamide Aluminum Glass Steel, zinc plated NBR (Viton on request) Mounting position In the min./max. oil level range on the side wall of the hydraulic oil reservoir. Ambient temperature range - 13 F... + 180 F Q u a l i t y A s s u ra n c e Quality management according to DIN EN ISO 9001 Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Our engineers will be glad to assist you with questions concerning filter application, selection, and cleanliness class of the filtered medium attainable under practical operating conditions. Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. We produce fluid power solutions ARGO-HYTOS Inc. P.O. Box 28 Bowling Green, OH 43402 USA Tel: +1-419-353-6070 Fax: +1-419-354-3496 info.us@argo-hytos.com www.argo-hytos.com Subject to change 9107224-us 0206 222