C C C C C C With mounting bolts Bolt thread up to M10 Dipstick length up to 25.2 inch. 70.

Similar documents
Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us

High Pressure Filters Worldline 400 HD 790 HD 990. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.

DG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e

High Pressure Filters HD 044 HD 064. Flangeable Operating pressure up to 500 bar Nominal flow rate up to 105 l/min e

Off-line Filters FNS 060. With flow control valve Operating pressure up to 320 bar Nominal flow rate up to 4 l/min e

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

High Pressure Filter Kits HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

L L L L Connection up to M60 x 2 Nominal flow rate up to 850 l/min

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm

D 162 D 232 D 332 In-line mounting Operating pressure up to 63 bar Nominal flow rate up to 350 l/min

FNK 050 FNK 100 Operating pressure up to 10 bar Nominal flow rate up to 125 l/min Cooling capacity up to 45 kw

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm

FN 060 FN 300 In-line mounting Operating pressure up to 12 bar / 174 psi Nominal flow rate up to 650 l/min / 172 gpm

DG 060 DG 061 DG 062 DG 063 DG 064 for Pressure and High Pressure Filters Operating pressure up to 600 bar Response/switching pressure up to 5,0 bar

Water Absorbing Filter Elements

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619 Operating pressure up to 630 bar Nominal flow rate up to 450 l/min

Cleanline portable. Oil Service Units FA 016 / FAPC 016

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements

ES 094 Tank top mounting Connection up to G1¼ Nominal flow rate up to 70 l/min

Functional Description

VJO1-06/S. Functional Description HA /2010. Check Valves. Replaces HA /2008. Size to 06 (1/4) bar (4600 PSI)...20 L/min (5.

VRN2-10. Functional Description HA /2008. Pilot Operated Pressure Reducing Valves. Replaces HA /2003

VPN2-10/MR. Functional Description HU /2008. Pilot Operated Pressure Relief Valves. Replaces HU /2005

VJL Functional Description. Ordering Code VJL Spare Parts HA /2002. Logical 3-way check valves. Replaces HA /2001

VPN1-06. Functional Description HA /2008. Pilot Operated Pressure Relief Valves. Replaces HA /2002

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

Clogging Indicators. Description. Page 393. Application Monitoring the contamination of pressure and high pressure filters.

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012

RPE2-04. Functional Description HA /2002. Solenoid Operated Directional Valves. Replaces HA /2000

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

FA 016 FAPC 016. Oil Service Units. Description. Page 53

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min

VPP2-04. Functional Description HA /2003. Directly operated pressure relief valves. Replaces HA /2002

SR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2012. Replaces HA /2010

3/2 Way Ball Valves KHB3K

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2014. Replaces HA /2013

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010

VSK. Functional Description HA /2008. Constant Flow - Control Valves VSK4 VSK2 VSK2 VSK4. Replaces HA /2000

5.1 MEDIUM HEAVY DUTY SERIES SIZE 2

UM 045 UMPC 045 Oil service - simple, quick and compact with integrated particle monitor

Return line and Suction Boost Filter RKM

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

Pressure reducing valve, direct operated

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

Return Line Filter RFM with 4-Hole Mounting

Inline filter with filter element according to DIN 24550

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

Radial piston motor for compact drives MCR-C

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

Level indicators, screw plugs

Overview. Bosch Rexroth Corp /11 Aluminum Framing. Linear Motion and Assembly Technologies. Section 8: Air Supply Elements

up to size 381 up to PN 0.5 bar up to T = 80 C Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TSE

TECHNICAL CATALOGUE BALL VALVES: VIENNA

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

DA/SR. Pneumatic Rotary Actuators FEATURES VALBIA ISO 9001 CERTIFIED

Radial piston motor for heavy duty wheel drives MCR-W

BEV. Deep well vertical pumps. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

Radial piston motor for frame integrated drives MCR-A

Pressure reducing valve, pilot operated

Check valve cartridge Type M-SR

GLOBAL STANDARD COOLER

Directional Control Valves

Return Line Filter RFM with 4-Hole Mounting

Pressure relief valve, pilot operated

Hydraulic Motor (Radial piston multi-stroke)

Directional Control Valve Series 4D01 (DENISON)

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

1.3 HIGH PRESSURE SERIES

20 l/min (5 GPM) p max. Technical Features

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

2/2-way poppet valves with solenoid operation Type KSDER1

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Pneumatic Rotary Actuators

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

External Gear Pumps Series F

MINIMAT Screwdrivers. Handheld Screwdriver pneumatic

GLOBAL STANDARD COOLER

Functional Description HA /2005. Compact power packs SMA 03. Replaces HA /2003. p max up to 200 bar Q max up to 0,5-17 L/min

Change-Over Pressure Filter DFDK

Fluid Cooling Industrial COLW Series

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

Transcription:

O i l L e v e l D i p s t i c k s C4.0410 C4.0412 C4.0421 C4.0431 C4.0450 C4.0464 With mounting bolts Bolt thread up to M10 Dipstick length up to 25.2 inch 70.10-2us

D e s c r i p t i o n Application Controlling the oil level in hydraulic oil or lubricant reservoirs Construction and function ARGO-HYTOS oil level dipsticks are robust semicircular metal rods with an O-ring seal. A mounting bolt with a suitable hole is supplied with each dipstick. Dipsticks are available in various lengths, with various markings, and with various mounting bolts (see selection chart). Special features The robust material withstands even the most severe operating conditions The integral O-ring provides a 100% tight seal A suitable dipstick mounting bolt can also replace one of the mounting bolts of an in-tank return or suction filter Mounting The bolt supplied with the oil level dipstick is installed either in a separate threaded hole or in an already existing mounting hole for an in-tank filter. This eliminates the need of an extra mounting hole. If used as a filter mounting bolt, care should be taken to provide a proper seal between the tank, the filter and the mounting bolt. S e l e c t i o n C h a r t Part No. Dipstick dimension L1 Dipstick dimension L2 Dipstick dimension L3 Mounting bolt Grade Remarks inch inch inch 1 2 3 4 5 7 8 C4.0410-00330 3.94 - - SV.2810.05 8.8 - C4.0410-01330 3.94 3.74 2.52 SV.2810.05 8.8 - C4.0412-00330 4.72 - - SV.2810.05 8.8 - C4.0412-03330 4.72 3.82 1.85 SV.2810.05 8.8 - C4.0412-04330 4.72 3.94 2.95 SV.2810.05 8.8 - C4.0421-00330 8.27 - - SV.2810.05 8.8 - C4.0421-04330 8.27 4.65 3.46 SV.2810.05 8.8 - C4.0421-06330 8.27 2.80 1.81 SV.2810.05 8.8 - C4.0431-00330 12.20 - - SV.2810.05 8.8 - C4.0431-01330 12.20 7.48 6.30 SV.2810.05 8.8 - C4.0450-00330 19.68 - - SV.2810.05 8.8 - C4.0464-00330 25.20 - - SV.2810.05 8.8 - C4.0464-01330 25.20 24.80 3.54 SV.2810.05 8.8 - Remarks: The dipsticks listed in the chart are standard dipsticks. If modifications are required, e.g. for the use in pressurized tanks, we kindly ask for your request. 216

D i m e n s i o n s Dipstick with bolt G Dipstick øb H O-ring ARGO-HYTOS Part No. N007.0043/2 (included in basic equipment) ø A E A/F C Bolt F L3 D L2 L1 Level marks D i m e n s i o n s Bolt A B C D E F G H A/F SV.2810.05 0.39 0.15 0.18 M10 0.28 1.18 0.39 1.54 17 mm 217

C h a ra c t e r i s t i c s Operating pressure Max. 14.5 psi (abs.) (Not suitable for use in pressurized hydraulic oil tanks) Connection Threaded ports according to ISO 228 or DIN 13. Sizes see section Dimensions (other port threads on request) Materials Dipsticks: Bolts: Seals: Steel, zinc plated Steel, zinc plated NBR (Viton on request) Mounting position Preferably in vertical position, above the oil level Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info-sheet 00.20) Temperature range - 22 F... + 212 F (temporary + 257 F) Ambient temperature range - 22 F... + 176 F (temporary + 212 F) Q u a l i t y A s s u ra n c e Quality management according to DIN EN ISO 9001 Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Our engineers will be glad to assist you with questions concerning filter application, selection, and cleanliness class of the filtered medium attainable under practical operating conditions. Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. We produce fluid power solutions ARGO-HYTOS Inc. P.O. Box 28 Bowling Green, OH 43402 USA Tel: +1-419-353-6070 Fax: +1-419-354-3496 info.us@argo-hytos.com www.argo-hytos.com Subject to change 9107223-us 0206 218

O i l L e v e l G a u g e s C5.3511 C5.3516 C5.3529 With thermometer Indication range up to 7.64 inch Temperature indication up to 180 F 70.50-3us

D e s c r i p t i o n Application Indicates the oil level and the oil temperature in hydraulic oil or lubricant reservoirs. Construction and function ARGO-HYTOS oil level gauges consist of a robust metal housing equipped with a sight level tube and built-in thermometer. The fluid enters the thermometer chamber through the mounting bolts, which are hollow. O-rings provide a seal against the housing and the reservoir wall. Special features The robust metal housing is designed to withstand even the most severe operating conditions The integrated scale shows the oil temperature in C and F Mounting The hollow screws and the locking nuts supplied with the gauge, enable installation on the reservoir wall by using two bores. The locking nuts serve the purpose of retightening the bolts from the outside (tightening torque: 8 Nm). Threaded holes are required instead of smooth bore holes if the wall of the reservoir is more than 0.31 inch thick. S e l e c t i o n C h a r t Part No. Oil level indicating range E Total height B Temperature indicating range Temperature indicating range Mounting bolts inch inch C F lbs 1 2 3 4 5 6 7 8 Weight Remarks C5.3511-50 1.30 4.25 +20... +80 80... 180 M10 0.40 - C5.3516-50 2.91 6.26-10... +80 20...180 M12 0.53 - C5.3529-50 7.64 11.22-10... +80 20... 180 M12 0.71 - Remarks: The gauges listed in the chart are standard gauges. If modifications are required, we kindly ask for your request. 220

D i m e n s i o n s Black mark for maximum oil level Red mark for minimum oil level At the housing C5.3529-50 the field of view is split in half. M e a s u re m e n t s Type A B C D E F G H I K 1 K 2 L max. A/F A/F C5.3511-50 2.99 4.23 1.36 0.89 1.30 0.63 0.71 1.14 0.31 17 mm 17 mm M10 C5.3516-50 5.0 6.26 1.36 1.04 2.91 0.63 0.71 1.14 0.31 18 mm 17 mm M12 C5.3529-50 10.0 11.22 1.36 1.10 7.64 0.63 0.71 1.14 0.31 18 mm 17 mm M12 221

C h a ra c t e r i s t i c s Operating pressure Max. 29 psi (abs.) Connection Threaded ports according to DIN 13. Sizes see Selection Chart, column 6 and section Dimensions Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info-sheet 00.20) Temperature range - 4 F... + 180 F Materials Housing: Sight level tube: Skalenplatte: Thermometer: Bolts: Seals: Steel, powder coated, black Polyamide Aluminum Glass Steel, zinc plated NBR (Viton on request) Mounting position In the min./max. oil level range on the side wall of the hydraulic oil reservoir. Ambient temperature range - 13 F... + 180 F Q u a l i t y A s s u ra n c e Quality management according to DIN EN ISO 9001 Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Our engineers will be glad to assist you with questions concerning filter application, selection, and cleanliness class of the filtered medium attainable under practical operating conditions. Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. We produce fluid power solutions ARGO-HYTOS Inc. P.O. Box 28 Bowling Green, OH 43402 USA Tel: +1-419-353-6070 Fax: +1-419-354-3496 info.us@argo-hytos.com www.argo-hytos.com Subject to change 9107224-us 0206 222