Operation & Maintenance Manual. Sludge Vac. Visit our Website for more information on this product.

Similar documents
Operator s Safety and Service Manual

Operation & Maintenance Manual Industrial Downdraft Tables

Condensate Pump. Installation and Safety Instructions CP-22 CP CP-22LP CP-22LP-230

Condensate Pump. Installation and Safety Instructions CP-22 CP CP-22LP CP-22LP-230

G8 Portable Fuel Transfer Pump Owner s Manual

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

Product Owner s Manual. 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump. Model G8P

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

Chip Vacuum Removal System INSTRUCTION MANUAL

Operator s Safety and Service Manual

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

SEPARATOR PURGE KIT OPERATION & MAINTENANCE MANUAL

OPERATIONS MANUAL MODEL MT-500

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

AEROMOTIVE Part # /2 4.6L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Model G14SD Vapor Management System

Water Broom. Instruction manual ESPAÑOL: PÁGINA 7 FRANÇAIS : PAGE 13 MODEL PCA270

AEROMOTIVE Part # GM LS1 Fuel Rails INSTALLATION INSTRUCTIONS

DEMA Model 294D Spray Foam INSTALLATION INSTRUCTIONS

Installation & Service Manual for Portable Fume Collector. Model PFC-800

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

VEGETABLE OIL DISPOSAL UNIT (MSDU) OPERATOR & SERVICE MANUAL

AEROMOTIVE Part # Subaru Fuel Rails for Top Feed Injectors WRX & STI INSTALLATION INSTRUCTIONS

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

AEROMOTIVE Part # L 4V Fuel Rails INSTALLATION INSTRUCTIONS

Shortening Disposal Unit

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

Owner s manual for installation, usage and maintenance

SAMPLE COOLER and SLUDGE TRAP OPERATION & MAINTENANCE MANUAL

M-1115S Series Fuel Pump

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

Users Manual Certified Series Direct Drive Pump 1-7 LPM

Propane torch. Model Assembly And Operation Instructions

AEROMOTIVE Part # / L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

DA Series Diaphragm Valve

Operation & Service Manual

Installation, Operation & Maintenance Manual

LED Pinspot 2. Snapshot. User Manual

Product Information ROSS CONTROLS

LED Pinspot 2. Snapshot. User Manual

92831 TEL: (714) FAX:

AEROMOTIVE Part # Ford 5.4L Shelby GT500 Mustang INSTALLATION INSTRUCTIONS

Dispenser & Warmer RIC-1909 RIC-1909EXP

D Instructions/Parts. Siphon Feed Detail Spray Gun D

Product Information. L-O-X 15 Series ROSS CONTROLS

AEROMOTIVE Part # Ford 5.4L GT500 Shelby Mustang Fuel Rail Kit INSTALLATION INSTRUCTIONS

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS

AEROMOTIVE Part # L Ford F L Ford Expedition L Ford F-250 Super Duty INSTALLATION INSTRUCTIONS

1. Before operating the pump, read and understand these operating instructions.

"WHERE TUBING AND FITTINGS COME TOGETHER"

MRC 150/300 USER MANUAL. 1 Laird Technologies

Items # and #

Operation and Maintenance Instructions Manual BOOSTER. Volume amplifier

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Operating and Installation Instructions

Hydraulic Truck Jack

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

FPS-500. Fuel Polishing System Eliminates Microbial Contamination. Operating Manual

VICE MOUNTED BEAD ROLLER

810201,810202,810203,810204

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

T1-Titanium Non-HVLP Spray Gun

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

OPERATION & SERVICE MANUAL

Operating Instructions & Parts Manual

Air Actuated Hydraulic Bottle Jack on Wheels

FLOORMASTER 18B OPERATING & MAINTENANCE READ THIS BOOK

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

AEROMOTIVE Part # Subaru Fuel Rails for Top Feed Injectors WRX & STI INSTALLATION INSTRUCTIONS

OWNER S MANUAL PRODUCT CODE: BOD1907

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

AEROMOTIVE Volkswagen 1.8T Fuel Rail Part # INSTALLATION INSTRUCTIONS

ROSS CONTROLS.

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

DEBRIS MASTER INDUSTRIAL LITTER VAC GAS OPERATION MANUAL

IMS SERIES COMPRESSED AIR LOADER

INSTRUCTION AND MAINTENANCE MANUAL GFH45 PRESSURE REGULATOR

Rapid Digestor Fume Removal System

Air Control Kits INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

4. All Federal, State, and local safety codes should be followed.

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

Series K. Pneumatic. switch mechanism. and housings. Installation and Operating Manual

Product Information. 16 Series ROSS CONTROLS

Transcription:

DIVERSITECH Operation & Maintenance Manual Sludge Vac Visit our Website for more information on this product www.diversitech.ca 2500 Alphonse Gariepy, Montreal, Quebec H8T 3M2 Tel: 1.800.361.3733 Fax: 1.514.631.94801 info@diversitech.ca OMM-WV-55-17-10 [E N]

Table of Contents SECTION 1 SAFETY PRECAUTIONS OF LIQUID & SOLID COLLECTION...3 1.1 Symbols...3 1.2 User Responsibility...3 1.3 Liquid & Solid Collection Hazards...3 SECTION 2 SPECIFICATIONS...4 2.1 Diagram & Description...4 2.2 Specifications & Dimensions...4 2.3 Replacement Parts...4 SECTION 3 SETUP / INSTALLATION...5 3.1 To Setup or Install Safely...5 3.2 Un-Packaging...5 3.3 Selecting a Location...5 3.4 Installation...5 3.5 Preparing Unit for Operation...6 SECTION 4 OPERATION...7 4.1 To Operate Safely...7 4.2 Using The Sludge Vac...7 4.3 Changing The Filter Bag...8 SECTION 5 MAINTENANCE & TROUBLESHOOTING...8 5.1 To Maintain this Product Safely...8 5.2 Tools Required...9 5.3 Cleaning & Troubleshooting Procedure...9 APPENDIX 3 MAINTENANCE RECORD...10 NOTES...11,12,13,14,15 Limited Equipment Warranty...Back Cover Freight Claims...Back Cover Return Material Policy...Back Cover

SECTION 1 - SAFETY PRECAUTIONS OF LIQUID & SOLID COLLECTION!! READ BEFORE USE DO NOT USE This manual contains specific cautionary statements related to worker safety. To protect yourself and others, read this manual thoroughly and follow as directed before use. Not all hazards of fume & dust control are listed in this manual, and no hazards related to welding, cutting, grinding, painting, deburring or other applications are listed. Consult a qualified safety professional. Do not use this equipment: To collect flamable liquids such as fuel oil, alcohol, mineral spirits, gasoline or kerosene. With any material with a low flash point. 1.1 Symbols This manual uses several symbols to highlight specific hazards. Be familiar with these symbols and when you see them in this manual, read adjoining warning text to avoid the hazard. LOW FLASH POINT FLAMMABLE LIQUIDS 1.2 Users Responsability Improper use can be hazardous. It is your responsibility to follow all applicable ANSI, OSHA, UL, CSA, National & Local Fire Codes, and other regulatory guidelines covering the safe use of this equipment. Before use, inspect the unit for damage and verify it is working properly. Only qualified persons should install, operate, maintain, or repair this unit. Do not modify or repair the unit with parts or accessories not supplied by the manufacturer. Consult manufacturer s instructions for cleaning. 1.3 Liquid & Solid Collection Hazards Liquids such as fuel oil, alcohol, mineral spirits, gasoline or kerosene are flammables. Do not use or install equipment where any potential flammable liquids are present. Never use or install equipment where any material with a low flash point is present. If you are unsure if the product you purchased is correct for your application, call DiversiTech at 1-800-361-3733. 3

SECTION 2 - SPECIFICATIONS 2.1 Diagram & Description Knob Directional Flow Control Valve Barbed Connector Vacuum Hose Reusable Filter Bag 2.2 Specifications & Dimensions Model WV-55 Sludge Removal Vaccum Air Consumption Water Flow Rate Sound Level Net Weight Product Dimensions (in.) SCFM SLPM GPM LPM (lbs.) Width Height Length (in.) (in.) (in.) WV-55 19 538 30 114 86 dba 45 24 48 24 2.3 Replacement Parts ITEM NUMBER S-WV-0001 S-WV-0002 S-WV-0004 S-WV-0005 S-WV-0006 DESCRIPTION Replacement Bag Filter for WV-55-5 Micron 10 FT Replacement Vacuum Hose W/Cuffs for WV-55 Spill Recovery Kit: 54 Wand and Floor Tool for WV-55 Replacement Reversible Drum Vac for WV-55 Replacement Directional Valve Rebuild Kit for WV-55 4

SECTION 3 - SETUP / INSTALLATION 3.1 To Setup or Install Safely! Do not place unit near flammables or combustible surface. 3.2 Un-Packaging 1. Immediately upon receiving the unit, carefully examine the carton for damage during transit. 2. Remove packing material. 3. Avoid tipping or inverting during handling. 4. The item serial number and model, are listed on the nameplate. Record this information in the Maintenance Record provided in APPENDIX 2: Maintenance Record, or your own preventative maintenance system. 3.3 Selecting a Location Choose a location where the unit will be used, near the operator. 3.4 Installation 5

COMPRESSED AIR LINE SIZES Compressed air lines should be sized to hold pressure drops to a minimum. When installing supply lines, use 1/4 pipe up to 25 long, 3/8 up to 50 long. Compressed air hose (not included) should be 3/8 I.D. up to 25. Do not use restrictive fittings such as quick connects that can starve the Sludge Vac by causing excessive line pressure drop. COMPRESSED AIR SUPPLY The Sludge Vac uses normal shop air supplies of up to 100 PSIG (6.9 BAR, 689 kpa). With proper filtration and separation of dirt, moisture and oil from the compressed air supply, the Sludge Vac will run for years with no maintenance required. Maximum pressure is 250 PSIG (17.2 BAR. 1.72 MPa). Use a 10 micron or smaller filter separator on the compressed air supply (Automatic Drain Filter Separator not included). To prevent problems associated with oil, use an oil removal filter (Oil removal Filter, not included). The oil removal filter should be used downstream from the automatic drain filter separator. Filters should be used close to the Sludge Vac, within 10 to 15 is best. If air preparation units other than Diversitech models are being used, please note the following: PRESSURE REGULATORS - Must be pressure relieving and rated for a supply pressure of 250 PSIG (17.2 BAR,1.72 MPa). Suggested operating pressure is 5-125 PSIG (0.3-8.6BAR, 34-862kPa). Flow should be minimum 24 SCFM (680 SLPM). AUTO DRAIN FILTER SEPARATORS - Must be rated for a supply pressure of 250 PSIG (17.2 BAR, 1.72 MPa) and have 5 micron filtration. Flow should be minimum 24 SCFM (680 SLPM). OIL REMOVAL FILTERS - Must be rated for a supply pressure of 250 PSIG (17.2 BAR, 1.72 MPa) and have 0.03 micron filtration. Flow should be minimum 24 SCFM (680 SLPM). 3.5 Preparing Unit for Operation Remove the box of components and accessories from inside the drum. Tilt the top of the Model S-WV-0001 Filter Bag 90 degrees, slipping it over the Filter Bag Adapter, then pull down to secure. Place the drum lid on the drum and secure in place with the locking ring. The Sludge Vac uses Diversitech s S-WV-0005 Reversible Drum Vac (two way drum pump) to move the liquid in and out of the drum. Connect the Manual Shutoff Valve outlet to the compressed air inlet of the pump. The stainless steel pump assembly mounts into the small 3/4 NPT threaded hole of the drum (turning clock-wise). Slide the S-WV-0002 Vacuum Hose onto the barb fitting. Insert the Chip Wand at the other end of the vacuum hose. Connect the Compressed Air Hose to the inlet of the Manual Shutoff Valve on the pump (turning clock-wise). For most applications. it will be more convenient to have the swivel end of the hose located near the shutoff valve. Connect the other end to a source of clean, dry compressed air. Use a 10 micron or smaller filter separator on the compressed air supply (Automatic Drain Filter Separator not included). To prevent problems associated with oil, use an oil removal filter (Oil removal Filter, not included). The oil removal filter should be used downstream from the automatic drain filter separator. Filters should be used close to the Sludge Vac, with in 10 to 15 is best. Place Sludge Vac Directional Valve Assembly onto the two fittings protruding from the lid. Secure the two quick release fittings (lever locks point upward when locked). 6

SECTION 4 - OPERATION 4.1 Operate Safely! Read and understand SECTION 1: Safety Precautions and SECTION 4: Operation before use Read and understand all Material Safety Data Sheets and Manufacturer s instructions of all process materials, consumables, and equipment used in conjunction with this equipment. Do not place unit near flammables or combustible surface. Do not use product to collect flamable liquids such as fuel oil, alcohol, mineral spirits, gasoline or kerosene. If you are unsure, call a DiversiTech representative at 1-800-361-3733 4.2 Using The Sludge Vac When preparing to vacuum the contaminated liquid into the drum, move the directional valve into the position as indicated by the label on the drum lid. (The Directional Valve Assembly handle extends toward the stainless steel Reversible Drum Vac pump.) Turn the knob on top the Reversible Drum Vac pump counter-clockwise to FILL DRUM, then.turn the manual shutoff valve to the on position. To pump clean liquid out of the drum, move the directional valve into the position indicated by the label on the drum lid. (The Directional Valve Assembly handle extends away from the stainless steel Reversible Drum Vac pump.) Turn the knob on top the Reversible Drum Vac pump counter-clockwise to EMPTY DRUM then, turn the manual shutoff valve to the on position. It is normal for the drum lid to make a popping sound as the drum fills or empties. An automatic safety shutoff valve prevents spills or overfilling. 7

4.3 Changing The Filter Bag Disconnect the compressed air supply. Unlatch and remove the locking ring from the drum lid. Slide the lid to the side which provides access to the filter bag. There is a wire ring in the top of the filter bag that seats on the filter bag holding assembly. To remove the filter bag, lift the bag up from the bag holding assembly and tilt it sideways. The ring can then be removed from the bag holding assembly (filter bag can be removed from the drum). A new bag can be installed by tilting the ring, and pushing it over the bag holding assembly. It will then easily seat itself and is ready for use. SECTION 5 - MAINTENANCE & TROUBLESHOOTING 5.1 To Maintain this Product Safely! Read and understand SECTION 1: Safety Precautions and SECTION 4: Operation before maintenance. Never use or install equipment where any material with a low flash point is present. Keep away from flamable liquids such as fuel oil, alcohol, mineral spirits. 8

5.2 Tools Required GLOVES WASTE CONTAINER 5.3 Cleaning & Troubleshooting Procedure The safety shutoff float of the Reversible Drum Vac pump extends into the drum and may require occasional cleaning. Immerse the pump assembly in a mild cleaning or degreasing solvent. After cleaning, be sure the float moves freely. Use an air gun to remove solution and contaminants. If the stainless steel pump becomes clogged it can be disassembled for cleaning. Use a wrench to hold the hex body firm while turning the cylindrical muffler assembly counterclockwise with a strapping wrench. Once the muffler assembly is removed use a pin-style. spanner wrench to unscrew the threaded plug. Carefully remove the shim and clean it, the O-ring and the pump body using a mild cleaning solvent. Be sure all components are dry before reassembling. Note the orientation of the shim as shown in the illustration below and reinstall the threaded plug. Be careful not to over tighten the threaded plug as this can distort the shim and restrict airflow. Always clean the vacuum hose and attachments after every use. If routine cleaning does not solve your performance problems, please contact a DiversiTech representative at 1-800-361-3733 Clean air is essential for proper operation of the Sludge Vac. A 10 micron or smaller filter separator must be used on the compressed air supply near the Sludge Vac. If the filter element becomes clogged with dirt, or a filter with a larger micron rating is us used and passes dirt into the pump, the airflow becomes restricted and the pump can cease to operate. For replacement or repair filter and regulator parts, contact Diversitech at 1-800-361-3733 or info@diversitech.ca 9

APPENDIX 3 - MAINTENANCE RECORD DiversiTech Inc. authorizes this page to be photocopied or otherwise reproduced as needed for management of maintenance records. MANUFACTURER: DIVERSITECH INC. MODEL N SLUDGE VAC SERIAL N SERVICE LOCATION: CONTROL N Date Description of Service Serviced By Location Comments Only use manufacturer approved replacement parts on this unit. 10

NOTES 11

NOTES 12

NOTES 13

NOTES 14

NOTES 15

LIMITED EQUIPMENT WARRANTY For a period of 2 years from the date of purchase, all Diversitech products are warranted to be free from defects in material, workmanship, and construction, when used in accordance with installation, maintenance instructions, and expressly stated proper use application(s). Diversitech Inc. will repair or replace, at our option, any defective parts which fail during the warranty period. This warranty is limited to replacement parts ONLY, and does not cover personal liability, property loss, normal wear; and does not cover losses resulting from (or due to) improper installation, inadaqueate maintenance, misapplication, misuse, or use above rated capacities. FREIGHT CLAIMS Shipments must be inspected upon arrival. All Diversitech units are sold ex-plant. Therefore, it is the receiver s responsibility to file any freight claims with the carrier for obvious or concealed damages. Damaged shipments must be refused at time of receipt, by consignee. RETURN MATERIAL POLICY Prior to the return of material, for whatever reason, a return manufacturing authorization number (RMA#) is required from the Diversitech customer service department. This procedure is necessary for proper control and handling of returned materials. Call 1-800-361-3733 or email support@diversitech.ca to obtain an RMA. All material must be returned prepaid. Credit will be given for returns for warranty repair or replacement. Freight collect shipments, or freight without an RMA, will not be accepted. It is the shipper s responsibility to ensure that material being returned to Diversitech is adequately packaged for shipment to preclude damages. DIVERSITECH Visit our Website for more information on this product www.diversitech.ca 2500 Alphonse Gariepy, Montreal, Quebec H8T 3M2 Email: info@diversitech.ca