Mounting- and operating instructions Indoor Air Quality Guard LGW-13 CO 2 Detector

Similar documents
Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Carbon Dioxide (CO2) + Humidity (rh) + Temperature (T) transmitter with Display for room mounting. Features

Condensation monitor

EGQ 212: Duct transducer, CO 2 and temperature

OPERATING INSTRUCTIONS

Series 7000 Torque Sensor for PTO-shafts

Series 7000 Torque Sensor for PTO-shafts

VA-7450 Series. Electric Valve Actuators

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Assembly and Operating Instructions

Operating Instruction for Electronic Pressure Switch. Model: PDD

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

SPG-DIGI. Operating Instruction. Please read carefully before use!

Temperature multi-function calibrator Model CTM

GE Sensing & Inspection Technologies

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

LS-1 Series Tungsten Halogen Light Sources

Product information. ORION-PB Poultry computer for floor keeping

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

GE Measurement & Control

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating Instruction for Flowmonitor. Model: DF-WM

Ultra Sine Inverter (US) Generation 4 (G4) User Guide

testo 535 Instruction manual

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Intelligent Positioner

Differential pressure sensor

Operating instructions Accu Jet

Electrical Installation

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

SAFETY- FLY 700 P USER MANUAL FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS NR MIT

Solenoid valves MHJ, fast-switching valves

DKG-114 MANUAL AND REMOTE START UNIT

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

ES 200 STANDARD ES 200 EASY PLUS

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

Differential Pressure Sensors

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

User Manual Rittal PMC UPS 6kVA

Carbon Monoxide Transmitter

AWZ 110. AWZ 13,8V/1A/7Ah/LM

LGT-311L Bumper LED Light Kit EZ-Go RXV Installation Instructions

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

VOC Duct and Rough Service Sensor

Operating Instructions for Paddle Flowswitch Model: PPS-...

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

Technical Data and Operating Instructions Thermal Dry Running Protection ATLS-T1

Control Box CBJ1 / CBJ2. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA29. Data sheet LINAK.COM/HOMELINE

MWF+ Application. Types Available. Average temperature sensor. Datasheet

Ventilation Control. Ventilation Control 12

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

System 350 P352AB Electronic Pressure Control Series

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

BNC BNC 12V/8x1A. Switch mode power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition:

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

SAVE THESE INSTRUCTIONS

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

User Manual. Solar Charge Controller 3KW

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Know-how makes the difference. Limit Switches

OPERATING INSTRUCTIONS C.A.R. Controlled Asphalt Replaster TYPE 30/275 TYPE 60/75 TYPE 90/100 TYPE 120/125 TYPE 120/150

Instruction manual Electric glass door lock Touch-to-open

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition:

SIGNET Temperature Transmitter

EPS/ELA-Series User Manual EPS/ELA 250W

EXKOP MINI + QV II Quench Valve. Explosion Isolation System

Product information. MIRA-P Poultry computer

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch

ZONE PRESENCE SENSOR FEATURES SPECIFICATIONS TABLE OF CONTENTS. VAV system using a Zone Presence Sensor.

Translation of the Original operating instructions Lifting device Z 70 /...

CHEMTROL 460 Control unit Technical information

product data sheet Usage: Duty cycle: Max 10% or 2 minutes continuous use followed by 18 minutes not in use Ambient temperature: +5 to + 40 C

REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution

REVISED ATM72 Auto Transfer Module

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Electrical linear actuator with safety function MC100FSR/230

35 35A 50 50A 1 Single phase. Solid state power controller

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

RELAY BOX PRODUCT MANUAL IMPORTANT

IGLOO IGLOO EASY INSTRUCTION MANUAL

NT1-200, NT1-200/296 Battery Backup. NT1-200 Add-on Battery. Installation Instructions. Specifications. NT1-200, NT1-200/296 Battery Backup

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

TPE S-A-F-A-BUBE

LM 3188 PORT: LASER DUST MONITOR

Signet Pressure Transmitter

CETOP POSITION PAPER PP 07

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

8000 Series Liquid Flow Meters

Transcription:

Mounting- and operating instructions Indoor Air Quality Guard LGW-13 CO 2 Detector ZILA GmbH Neuer Friedberg 5 98527 Suhl Tel.: +49 (0) 3681 867300 Fax: +49 (0) 03681 8673099 Web: www.zila.de E-Mail: info@zila.de

Table of contents 1. Scope of Delivery... 2 2. Product description... 2 3. Product features... 2 3.1. Measuring Range... 2 3.2. Functions... 2 3.3. Technical data... 2 3.4. Operating- and ambient conditions... 2 3.5. LED bar graph... 2 3.5.1. Internal LED... 2 3.5.2. 10-digit LED CO2 display... 2 3.5.3. Relais LED... 3 3.6. Standards and Guidelines... 3 4. General safety instructions... 3 5. Mounting and Commissioning... 3 5.1. Installation position... 3 5.2. Mounting options... 3 5.2.1. Wall- and surface mounting... 3 5.3. tabletop unit with power supply... 4 6. Electrical connection... 4 7. Connection of actuating elements (examples)... 5 7.1. 24VDC ventilation device... 5 7.2. 24VDC electric window opener... 5 7.3. Ventilation devices with heat recovery. 5 8. Maintenance... 6 9. Support... 6 1. Scope of Delivery Indoor Air Quality Guard LGW-13 Mounting material for wall-mounting 24V power supply (optional) 2. Product description The LGW-13 is a versatile CO2 detector. The device has an optical (LED) and acoustic warning signal output (horn). Furthermore, a switching function for common 24 Volt actuators is integrated for use in industrial and domestic applications. The CO2 sensor is integrated in a compact housing made of white polycarbonate (IP 20). The Sensor is based on the optical measurement principle "NDIR" (nondispersive infrared absorption measurement).the device is available in various measuring ranges from 0...1 Vol% available. The LGW-13 has an integrated function monitoring and is maintenance-free. 3. Product features 3.1. Measuring Range The device measures the CO2 concentration in the ambient air in the range of 0...3000ppm (Standard). Other measuring ranges up 1,0vol% are available on request. 3.2. Functions used as a CO2 sensor with 0-10V and 4-20mA signal output Suitable as a tabletop unit with a power supply or for wall and surface mounting Air quality traffic light with 10 LEDs CO2 limit dependent switching function for 24 volt devices Integrated alarm horn with 2 volume levels 3.3. Technical data Dimension: (LxWxH): 120x80x35mm Further technical specifications can be found in the product-specific data sheet on our website www.zila.de. 3.4. Operating- and ambient conditions Operating temperature: -10...+50 C Storage temperature: -40...+100 C Relative humidity: 0..95 % (nicht kondensierend) Air pressure: 900...1100 hpa 3.5. LED bar graph 3.5.1. Internal LED The LED in the top ventilation slots indicates the status of the device and the internal monitoring function. The monitoring function operates when the device is turned on. If the LED is red, the device is working properly. If an error occurs, the LED is off. 3.5.2. 10-digit LED CO2 display The 10-digit display in the standard variant shows the CO2 concentration in the range of 0...3000ppm in 10 individual steps with 300ppm each. With increasing CO2 concentration, more LEDs permanently turn on from left to right. When reducing the CO2 concentration in accordance with the above steps, the corresponding LEDs turn off. Handbuch Version: DE_1606_TOLI_LGW13 2

3.5.3. Relays LED The LED on the left side above the 10-digit display indicates properly connected actuators and the switching state. If the CO2 limit is exceeded and the switching relay is triggered, the LED lights up yellow. 3.6. Standards and Guidelines Der Indoor Air Quality Guard LGW-13 complies with the following European standards and guidelines: 2014/30/EU (EMC Directive) DIN EN 61000-3-3:2014-03 DIN EN 61000-3-2:2015-03 You can mount the device on a wall in a few steps. Note: The following pictures were provided by the manufacturer of the housing and illustrate the mounting of the housing. Even though the actual device deviates from this image, then the procedure does not change during mounting. Step 1: Loosen the lower housing of the device from the cover by opening the holder. 4. General safety instructions Read safety instructions carefully Keep the instruction Mounting, commissioning and electrical connection of the LGW-13 without power supply may only be done by experts Repairs may only be done by experts The mentioned international protection marking applies only when mounting position and cable connection are correct Only operate the device at a given voltage Changes and modifications to the device are forbidden and releases the ZILA GmbH of any guarantee and liability Step 2: Place the bottom case as straight as possible to the wall in order to obtain a drilling template. Drill the holes. 5. Mounting and Commissioning 5.1. Installation position For an optimal indoor air quality with the LGW-13 a mounting height "at eye level" is recommended depending on the application. This means that the seat height of the people in rooms in offices with sedentary activities is crucial for the mounting height. The proper mounting position is horizontally. 5.2. Mounting options 5.2.1. Wall- and surface mounting Step 3: Mount the bottom cover with the supplied mounting materials on the wall. Caution: When mounting on the surface, the electrical wires must be fitted through the hole in the middle of the bottom case before firmly mounting the base plate on the wall. Handbuch Version: DE_1606_TOLI_LGW13 3

Connect the electric wires according to the circuit diagrams. section commissioning or connection of actuators 5.3. tabletop unit with power supply Insofar as a power supply is in the delivery, connect the power supply via the AC adapter jack on the left side wall of the upper housing cover with the device. 6. Electrical connection The upper section of the circuit board is provided for the electrical connection of peripherals such as 24-volt fans. Ventilation elements are connected via the terminals shown below. Step 4: Take the upper part of device and put it into the holder of the wall-mounted base plate. Close the device by pushing the top part. The LGW-13 is completely assembled when it snaps into the cradle. Seen on the screw Caution: electrical connection exemplary! For detailed information please refer to the The type of signal output from the sensor are picked up via the terminals X4, X5, X6 according to the next picture. The terminal X1 is the power supply, as far as the device is not powered via the power adapter. Handbuch Version: DE_1606_TOLI_LGW13 4

Ventilator configuration: JP1 and JP2 closed Ventilator-Connect on X3-1 and X3-3 Seen on the screw The jumpers are located on the circuit board next to the PINs, which are inserted into the terminal on the base plate during the closing of the housing. 7.2. 24VDC electric window opener The relay of the LGW-13 switches the applied supply voltage (+ 24VDC) of JP1 and the ground GND of JP2 alternately to the voltage input oft he window opener. 7. Connection of actuating elements (examples) 7.1. 24VDC ventilation device Window opener configuration: JP1 and JP2 closed FOE-Connect on X2-1 and X3-1 7.3. Ventilation devices with heat recovery The relay of the LGW-13 switches as a potential-free contact with a ventilation device with heat recovery. This ventilator normally consists of a supply fan and an exhaust fan as well as an own control for the ventilation stages. Optionally, these fans have a connection for an external CO2 switch. In this way, the ventilation unit is connected with the Indoor Air Quality Guard LGW-13. Handbuch Version: DE_1606_TOLI_LGW13 5

Ventilation device with heat recovery Configuration for heat recovery: JP1 and JP2 open WRG-Connect on X2-1 and X2-2 8. Maintenance The Indoor Air Quality Guard LGW-13 is maintenance free, thanks to NDIR technology. According to the application, a regular calibration of the device is recommened. 9. Support Telephone: +49 (0) 3681 86 73 00 E-Mail: support@zila.de ZILA GmbH Neuer Friedberg 5 98527 Suhl Tel.: +49 (0) 3681 867300 Fax: +49 (0) 03681 8673099 Web: www.zila.de E-Mail: info@zila.de Handbuch Version: DE_1606_TOLI_LGW13 6