Minimum quantity lubrication system MVE for external lubrication. Operation manual

Similar documents
Minimum quantity lubrication system MDE for external lubrication. Operation manual

Operating Instructions

Operating Instructions

Four Post Surface Lift

O P E R A T I N G M A N U A L

>IVH< >VVH< Shortening hook

Assembly and Maintenance Manual Type ASNU

Description. ST-164 Dual injector. User Manual ST-164. Artikel-Nr.: XXX

Mod: KLD6-12/35XLAS-N

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type AS

Dumper OPERATOR S MANUAL

RFID114. For use in combination with charge controllers used in electric vehicle charging stations, wall boxes or street light charging points.

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Operating and maintenance instructions

RSe Series. Operating Instructions. Safety Exhaust (Dump) and Safe Cylinder Return Control Reliable Double Valves. RC-RSe

Dumper 1001, 1501, 2001 OPERATOR S MANUAL

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019

STARPOINT. Safety instructions. Starpoint VRS (-F) Fax: Phone:

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Swing Piston Compressors and Vacuum Pumps

original operating manual Operating manual Translation of the Item-No.: ,

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

LubriLean Minimal Quantity Lubrication

Betriebsanleitung Operating Instructions. Diaphragm Pump

VSM480. Instruction Manual VARIABLE SPEED MIXER. Read instructions before operating this tool.

Verti Blast. User Manual. Order code: EQLED355

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

SKF VectoLub, VE1B units

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Turbocharger / TPS-H Original assembly instructions English

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Oil-free piston compressors KK and piston vacuum pumps KV

EASY CHARGE Weather-resistant fixed mount Battery Charger

Betriebsanleitung Operating Instructions. Rotary Vane Pump

Turbocharger / A100-L Original assembly instructions English

General Operating Manual

AIR LUBRICATION SYSTEM INSTALLATION

Crane fork KGM/KGA and KGQ/KGL

> VIP-Balancer < VIP-Balancer. VIP-Balancer

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

EASY CHARGE Waterproof portable Battery Charger

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

Product series DigitalSuper

SCOPELITE TIMING LIGHT OPERATING MANUAL

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

TM 60 TS 75 TS 100 Please read this user guide before using your operator. Please read carefully the security advises on the following pages!

Operating instructions Accu Jet

Starting up hydraulic systems

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Sugar beet covering eqipment

Assembly instructions

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

Document Library TS Data Sheet Universal Fuel System Cleaner. Data Sheet. Public

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Coolants can extend blade life, improve cut finish, and quicken cut rates

Load Ring for bolting >VLBG<

Swing Piston Compressors and Vacuum Pumps

Translation of the Original operating instructions Lifting device Z 70 /...

Instruction manual and installation guide Traction sheave brake TSB TSB

Owners Manual: - Pumps

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

DC Master 24/ A

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

General safety notes

English. Instruction and operation manual S 212. Dew point sensor

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

Compensation unit AGE-XY 50-80

CREATING POWER SOLUTIONS. 1D90V 1D90W. OPERATOR S MANUAL Diesel engine. Hatz Diesel.

USE and MAINTENANCE INSTRUCTION MANUAL W-300 W-300 WB LPH-300 GRAVITY. SPRAY GUN Series. en it fr es pt de se

Operator s and Maintenance Manual

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

HYDRAULIC POWER PACK

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Original Operating Manual

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

These installation and maintenance instructions must be read in full and completely understood before the installation!

Micro Diaphragm Gas Sampling Pumps

Load Ring for bolting >VLBG-PLUS<

EN. SKF Grease Spraying System For Large Open Gears. Extend the lifetime of large gear drives

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Register your instrument! HeatSealer S100. Operating manual

Turbocharger / TPL-B Original assembly instructions English

Micro Diaphragm Gas Sampling Pumps

HST-BL-2830MS & HST-BL-2830MS-USA

Hydraulic drive power unit Low-noise compact unit Whispering power unit

Printed: Doc-Nr: PUB / / 000 / 00

Application cup for OptiFlex 2 GM03 manual powder gun

KeContact P20. User manual

Universal spotlight LED

Operating Instructions

Technical Manual Electrical Power Supply System T4002

02OWNER S MANUAL 06 TROUBLESHOOTING 08LIMITED WARRANTY

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Transcription:

Minimum quantity lubrication system MVE for external lubrication. Operation manual

Table of Contents Table of Contents 2 Foreword 3 Instructions for use 4 Intended use 4 Safety instructions 5/6 Function description 7 Aerosol generation 7 Layout and function 7 Pictorial representation 8 Controls 9 Assembly 10 Initial filling 11 Commissioning 11 Flooding of the transport lines 12 Default 12 Check the settings 13 Switch off the system 13 Maintenance 13 Cleaning 14 Decommissioning 14 Technical specifications 15

Foreword Dear customer We would like to thank you for your confidence in our product. With the acquisition of a DYNACUT-MVE minimum quantity lubrication system for external lubrication, you have decided to use environmentally friendly and economical technology. Our high-quality minimal-quantity lubrication systems have been designed for use on modern machine tools. DYNACUT minimum quantity lubrication systems for external lubrication are built according to the generally recognized rules of technology and comply with the applicable occupational safety and accident prevention regulations. However, hazards may arise during their use, which can lead to physical damage to the user or to third parties or to damage to the machine tool or other property. In order to ensure trouble-free operation and to avoid dangers, please read this operating instructions carefully and observe the notes contained therein. Dynacut UG (haftungsbeschränkt) Gewerbering 3 48734 Reken E-Mail sales@dynacut.eu Homepage www.dynacut.eu

Instructions for use Texts marked with this symbol indicate special dangers or mark work which requires special caution. This manual contains a general description of the system, as well as instructions for installation and operation. The system also examines the specificity of the system. Use the table of contents to find the information you need quickly and securely. This operating manual is an integral part of the system and must be handed over to the new operator when the system is sold. Intended use The DYNACUT-MVE minimum quantity lubrication must only be used and used according to the instructions given in the operating instructions. In particular, we would like to point out that hazardous substances of any kind, especially substances classified as dangerous according to EC Directive 67/548 / EEC, Article 2, paragraph 2, as well as liquids such as chlorinated hydrocarbons, solutions with alcohol contents of more than 30% Gasoline, nitro lacquers and nitro diluents (solvent mixtures for nitro lakes from hydrocarbons and esters) and concentrated acids must not be filled into and distributed with DYNACUT minimal-quantity lubrication systems and components and / or distributed with them. The minimum quantity lubrication system described here is intended exclusively for the external lubrication of machining and forming processes. During external lubrication, the lubricant is transported directly to the friction point between tool and workpiece via spray nozzles, which are attached to the machine tool. Depending on the type of processing, one or more spray nozzles per tool can be used. The DYNACUT-MVM minimum quantity lubrication system can be used both for the initial equipment of processing machines and for the retrofitting of processing machines with an existing cooling lubricant supply. Any other use or use beyond this is considered to be improper. Dynacut UG is not liable for damages resulting from this. The lubricants suitable for use in DYNACUT minimal-quantity lubrication systems for external lubrication are specially adapted to the high requirements of the technology used in their chemical and physical properties. For this reason lubricants suitable for minimum quantity lubrication may be used.

We cannot assume any liability for damage caused by improper use of lubricants or by the use of lubricants suitable for minimum quantity lubrication. Safety instructions Please observe the following safety instructions in order to ensure the trouble-free functioning of the minimum quantity lubrication system and to avoid damage. Spraying of lubricants or substances which are released for minimum quantity lubrication with DYNACUT minimum quantity lubrication systems is not permissible. Prior to any work on the system, e.g. cleaning or replenishing lubricant, etc., the system must be disconnected from the compressed air supply and depressurized. The system must also be disconnected from the electrical power supply. Humans or animals must not be aerosolized. The aerosol must not get into the eyes and should not be inhaled directly. Observe well-ventilated areas and, if possible, install suction on the machine. We point out that the spraying of mineral oils or mineral oil-containing substances can lead to health damage. Any kind of fire e.g. in the form of open flames, sparks, glowing cigarettes, etc., must not get into the vicinity of the spray jet. The aerosol must not be sprayed on hot surfaces. The generally valid rules and safety regulations for the work with compressed air and electrical voltage carrying machinery and equipment must be observed. The system may only be used in a technically perfect condition as well as in accordance with its intended purpose, in accordance with safety and driving safety, observing the operating instructions. The existing safety devices must not be damaged, immobilized or rendered unusable or replaced by parts other than those expressly approved by Dynacut UG. In the event of a fault, the system should be disconnected as soon as possible from the compressed air and voltage supply, e.g. by actuating the quick coupling on the compressed air connection and pulling the mains plug. The unauthorized conversion of the system as well as the use of unauthorized spare parts and accessories are not permitted. Used systems must be rendered unusable and then properly disposed of.

Function description Principle of minimum quantity lubrication (MQL) The minimum quantity lubrication is a loss or consumption lubrication, this means, the lubricant used is almost completely consumed during processing, so that preparation in the circuit is no longer necessary. The actual lubrication task at the point of action between the tool and the workpiece is achieved by means of oil droplet, the aerosol, which is finely dispersed in an air stream. With the minimum quantity lubrication, an effective lubrication of cutting processes can be achieved using the smallest amounts of lubricant. The elaborate cleaning and disposal of large quantities of lubricating and cooling lubricants are thus eliminated or minimized. Aerosol generation The minimum quantity lubrication system DYNACUT-MVE described here produces a very homogenous aerosol as the lubricant is atomized in a controlled manner. The function principle of the spray nozzles makes it possible to create a very fine mist due to the venturi effect. The fogging is dependent on the set air pressure. Layout and function The DYNACUT-MVE minimum quantity lubrication system consists of a lubricant reservoir, one or several mixture regulating units and one or several lubricant lines with spray nozzle. By switching the main switch open the solenoid valves for air and coolant. As a result, compressed air is transported to the spray nozzle via a hose. The venturi effect at the nozzle creates a vacuum in the coolant hose whereby coolant is sucked from the reservoir. The required lubricant and atomizer air quantity is regulated by means of the throttle valves mounted on the mixture regulating unit. At the end of the lubricant line is a spray nozzle, with the help of which the aerosol is generated. The lubricant reservoir is filled with lubricant by opening the filler plug in the container cover with an Allen key (10 mm) and filling the lubricant.

Pictorial representation 7 1 2 Description 1 Reservoir for lubricant 4 2 Optical level indicator 3 Mixing head 4 Regulating valve atomizing air 5 Regulating valve lubricant 6 Spray nozzle 6 3 5 7 Power plug

Controls 8 11 9 12 10 Description 8 Main switch 9 Solenoid valve atomizer air 10 Solenoid valve lubricant 11 Air connection 6 mm 12 Filling plug

Assembly Installation: The minimum quantity lubrication system should be set up close to the processing machine. We recommend mounting the system directly on the machine housing. Do not install the system in a location where it is exposed to strong vibrations. The system must not be placed near a heat source. Also unsuitable is a place that is exposed to fast and strong temperature fluctuations. The system must be installed vertically for proper operation. Under no circumstances should it be installed upside down. The lubricant reservoir should be mounted higher than the spray nozzle. This facilitates the coolant flow to the nozzle. Also ensure good accessibility for the purpose of maintenance or lubrication. Initial filling For the first use of the system it is recommended to fill the lubricant reservoir before connecting it to the compressed air and electrical power supply. After the lower lubricant tank has been unscrewed, this can be filled with coolant. Attention: Only suitable minimum quantity lubricants may be used as lubricants. Please note that we cannot assume liability for damage caused by the use of unsuitable lubricants. Be sure to close the filler plug after filling. Connections: The connection of the system may only be carried out by appropriately qualified and instructed personnel. The instructions contained in this operating instructions must be observed. Compressed air supply: Before connecting the compressed air line, ensure that the main air valve is closed.

The minimum quantity lubrication systems may only be operated with the specified maximum operating pressure. Higher pressure causes danger for human and machine. Commissioning: For the commissioning of the minimum quantity lubrication systems, the flooding of the transport lines, the setting of the operating parameters and a functional test are important. Flooding of the transport lines: In the delivery state, the capillary hoses of the transport lines are not filled with lubricant. In order to fill the often meter-long lines, the system would have to remain switched on for an extended period while the lubricant slowly travels to the spray nozzle. In order to speed up this process, a flooding of the transport lines should be carried out during initial commissioning. Long waiting times before the first use are thereby avoided. The procedure for flooding the transport lines is as follows: Close solenoid valves for atomizer air and coolant by switching off the main switch. Connect the system to the compressed air supply. Hold the spray nozzles as far down as possible into a lubricant collecting tank. Open solenoid valves by switching on (8). Fully open lubricant control valve (5) and air control valve (4) to increase lubricant flow. As soon as the lubricant emerges as a mist at the nozzle, close the lubricant control valve (5) and the air control valve (4) as far as possible. Close solenoid valves. Default The setting of the valves depends on all process parameters such as, Eg cutting speed, materials, cutting tool, etc., and must therefore be re-tuned on a case by case basis by the machine operator. The basic setting of the systems is as follows: Turn on solenoid valves for atomizer air and coolant. Adjust the necessary lubricant quantity via the lubricant control valve (5). Adjust the quantity of atomizing air and thus the pressure via the atomizer air valve (4)

Check the settings Point the spray nozzle onto the cutting edge of the standing tool and observe if a lubricant film is formed. If necessary, increase the amount of lubricant or atomizing air. The distance between the spray nozzle and the tool tip should be kept as low as possible. If the distance is too long, the tool cutting edge is not sufficiently lubricated. Note: The larger the distance, the greater the spray angle of the spray nozzle. Start machining and adjust the aerosol quantity and the aerosol composition to the machining process by using criteria such as lubricant, cutting parameters, surface roughness and tool wear to change the setting. We recommend that you use test runs to determine and optimize the setting values required for your application in order to get the best result for your machining process. If necessary, use two spray nozzles, which are arranged at an angle of 180 to optimize the aerosol supply to the lubrication point. Switch off the system The minimum quantity lubrication is set in the reverse order of commissioning. Maintenance DYNACUT minimum quantity lubrication systems are low maintenance. However, to ensure proper operation and to avoid dangers from the start, you should check all connections and connections regularly.

Cleaning Cleaning outside: If necessary, the minimum quantity lubrication system can be cleaned with mild, materialcompatible (not alkaline, no soap) cleaning agents. For safety reasons, we recommend that the minimum quantity lubrication system be disconnected from the compressed air and electrical voltage supply and that the container must be depressurized. When cleaning, connect the hoses as far as possible and close any openings so that no cleaning agents can penetrate into the interior of the minimum quantity lubrication system. Cleaning inside: In normal operation and when using lubricants which are compatible with each other, an internal cleaning is not necessary. If an incorrect or dirty lubricant has been accidentally filled, an internal cleaning of the lubricant reservoir must be carried out. Decommissioning Temporary decommissioning For a temporary shutdown of the minimum quantity lubrication system, disconnect the entire system from the compressed air and electrical power supply and depressurize the tank. In the case of a longer shutdown, it is advisable to also drain the lubricant. Final decommissioning If you want to permanently shut down the minimum quantity lubrication system, please observe the legal regulations for the disposal of oil-bearing components.

Technical specifications Description Einheit DYNACUT MVE Reservoir Housing design Mounting position Capacity Coolant consumption Coolant outlets Mass Compressed air Input pressure max. Input pressure min. Operating pressure max. Air consumption Connections Compressed air connection Electrical connection for valves l ml/h Stck kg bar bar bar l/min mm V PE-plastic Vertical 1,5 0-100 1-2 3 8 3 8 50-80 6 230

Konformitätserklärung im Sinne der Maschinenrichtlinie Anhang II 1A Original-Konformitätserklärung Hersteller: Dynacut UG (haftungsbeschränkt) Gewerbering 3 48734 Reken Deutschland Bevollmächtigter für die Zusammenstellung der technischen Unterlagen: Produkt: Hermann Lensing Gewerbering 3 48734 Reken Deutschland Minimalmengenschmierung MVE Hiermit erklären wir, dass das oben genannte Produkt allen einschlägigen Bestimmungen der Maschinenrichtlinie 2006/42/EG entspricht. Das oben genannte Produkt erfüllt die Anforderungen der folgenden einschlägigen Richtlinien: Niederspannungsrichtlinie 2006/95/EG EMV-Richtlinie 2004/108/EG Folgende harmonisierte Normen wurden angewandt: EN ISO 12100-1:2003/A1:2009, Sicherheit von Maschinen Grundbegriffe, allgemeine Gestaltungsleitsätze Teil 1: Grundsätzliche Terminologie, Methodologie EN ISO 12100-2:2003/A1:2009, Sicherheit von Maschinen Grundbegriffe, allgemeine Gestaltungsleitsätze Teil 2: Technische Leitsätze EN 983:2009-06 Sicherheit von Maschinen Sicherheitstechnische Anforderungen fluidtechnische Anlagen und deren Bauteile - Pneumatik EN 60204-1/A1:2009-10 Sicherheit von Maschinen- Elektrische Ausrüstung von Maschinen- Teil 1: Allgemeine Anforderung EU Richtlinie 2011/65/EU RoHS Konformität Reken, den 12.02.2013