Big performance in a small package

Similar documents
Big performance in a small package

Big performance in a small package

Big performance in a small package

Big performance in a small package

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

UL Enclosed Disconnect Switches (Fused and Non-Fused)

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

UL/CSA Non-fused Disconnect Switches

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

LDisconnect Switches. Disconnect Switches

194R J S TY N1

L11 Fused and Non-Fused Disconnect Switches (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Just the right switch for your application

General information about motor protection

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Rotary Cam Switches. Rotary Cam Switches

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Compact Circuit Protector

Compact Circuit Protector

Load Break Disconnect Switches FSLBS

Rotary Disconnect Switches, Bulletin 194R

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

1489-M Circuit Breakers

SPEEDFAX TM 2011 Disconnect Switches Contents

Section Contents. Disconnect Switches

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Product Specification Sheet #3LD2.1

Series L9 UL-489 Miniature Circuit Breakers

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

Bulletin 1489 Circuit Breakers. Selection Guide

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

Technical data OT16E3 OT160E3 UL & CSA

KT4 Manual Motor Starter

ENCLOSED DISCONNECT SWITCHES

Ideal for use as a manual starter

Compact Circuit Protector (CCP)

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

For many applications

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Effective December 2015 Supersedes September 2013

FUSIBLE DISCONNECT SWITCHES

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Motor Controllers + Circuit Breakers

Bussmann series Quik-Spec Coordination Panelboard

SECTION SECTION. EATON 2014 Arrow Hart Buyers Guide

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Selection Guide Motor Control Device Solutions

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

SECTION. Watertight & Dust-Tight Plugs & Connectors

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

600V, Non-Fusible, (3-Pole, 3 Phase)

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web: -

Compact Circuit Protector (CCP)

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Series L9 UL489 Miniature Circuit Breakers

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Technical Information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

UL 98 Fusible Disconnect Switches

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

OTEC Transfer switch open transition

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:

Quik-Spec Electrical Gear

SECTION SECTION SECTION EATON 2016 Arrow Hart Buyers Guide

Selection Guide. Control Circuit and Load Protection

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions.

NEMA Contactors & Starters (Freedom)

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

1492-CB 1492-GH 1492-GS

Rotary Cam Switches. Rotary Cam Switches

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

Series KTU7 UL489 Molded Case Circuit Breakers

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

footprint of traditional fusible switches

KT4 Manual Motor Starters

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

Transfer switch OTEC and OTECSE open transition

Transcription:

11 Series 11 Fusible up to 800A & Non fusible up to 1200 Amps Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or Fusible Which is Best For Your Application? Application Data Typical Control Switch Typical oad Break Switch Typical Fusible Switch To learn the basic differences between control, load and fusible disconnect switches and how to apply them, ask your Sprecher + Schuh representative for publication no: Tech-MSD Sprecher + Schuh s 11 series of fused and nonfused disconnect switches complies with U98 service entrance requirements and is NFPA 79 complaint. This family of rod operated switches is suitable for applications that require small panel space and superior short circuit protection. Big performance in a small package 11 disconnects are rated up to 1200A and can be operated at up to 600V. They protect motors up to 500HP (@480V). The 11 may be installed on circuits capable of delivering up to 200,000A of short circuit fault current levels typically found in modern industrial facilities. The 11 30A & 60A fusible switches incorporate removable fuse carriers with an optional neon blown fuse indicator carrier. This range of switches and handles also features a Test mode for circuit testing via D7 contact blocks. These switches can be conveniently DIN-rail mounted or screw mount. The new expanded offering of the 11 disconnect series ranges from 100A through 1200A. The 11 Fusible switches are available from 100A up to 800A which are designed to be used with Class J & fuses. The 11 Non-Fusible switches are available from 100A up to 1200A. Optional auxiliary contacts can also be mounted on the switch for control circuit use. The 11 family performance comes in a compact design, leaving room for additional branch circuit components within the panel. Maximum protection for downstream equipment 11 switches are U98 as a branch circuit protection device and is engineered to provide excellent short-circuit protection for downstream equipment up to 200kA. The 11 fusible switches accept the latest smalldimension Class CC, J, and HRCII fuses. This Type 2 protection limits let-through currents to levels specified for IEC equipment, and ensures that when the short circuit is cleared, the device will be operable. Meets the toughest safety standards The 11 offers a modular universal internal handle which provides an interlocked handle for test mode use (30A/60A) and U508A and NFPA 79 compliance in North America. The 11 30A & 60A is equipped with removable fuse carriers which provide dead-front switch protection during fuse change-out. Fuse carriers with neon blown fuse indicators are also available as an option on 30A &60A models. Test mode D7 auxiliary contacts may be installed to provide test capability of control circuit without energizing the main contacts for the 11-30A/60A swicthes. The 11 switches meet IP20 for finger-safe wiring terminals and IP30 for touch-safe fuse carriers. NFPA 79 Compliant All 11 30/60A & 11 100A 800A Fusible switches are NFPA79 compliant, which meets the following guidelines under the NFPA 79 standards 5.3.3.1 and 6.2.3.1.2. The supply Circuit ing Device shall: Be provided with a permanent means permitting it to be locked in the open position only independent of the door position. Be operable, by qualified persons, independent of the door position without the use of accessory tools or devices. The interlocking means shall: Be reactivated automatically when the door is closed. Prevent closing of the disconnecting means while the enclosure door is open, unless an interlock is operated by deliberate action. International standards and approvals All Sprecher + Schuh 11 disconnect switches are U isted under File Number E47426, CSA, CE Marked and are designed to meet IEC 947-3, and applicable NEMA requirements. 28

Series 11 U/CSA Fused ➎ Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (A) 120V 240V 240V 480V 600V 125V 250V Catalog Number Price U Class CC and CSA HRCI-Misc Fuses ➋ 30 2 3 7.5 15 20 3 5 11-C30-1753 310 A1 U Class J and CSA HRCI-J Fuses ➋ 30 2 3 7.5 15 20 3 5 11-J30-1753 335 A1 60 3 10 15 30 50 5 10 11-J60-1753 435 B1 30A & 60A Typical 100 7.5 15 30 60 75 7.5 20 11-J100-1753 725 F5 200 ~ 25 60 125 150 15 40 11-J200-1753 1620 F6 400 ~ 50 125 250 350 20 50 11-J400-1753 3071 F7 600 ~ ~ 200 400 500 ~ ~ 11-J600-1753 5220 F8 U Class and CSA HRCII- Fuses 800 ~ ~ 200 500 500 ~ ~ 11-800-1753 6786 F9 CSA HRCII-C Fuses 11-J100A...800A Typical 30 2 3 7.5 15 20 3 5 11-H30-1753 326 B1 60 3 10 15 30 50 5 10 11-H60-1753 426 B1 Items in Gray available by Special Order only. Dimension Code U/CSA Non-Fused ➌ ➍ Maximum Horsepower Amp No. 1 Ø (60Hz) Three Phase (60Hz) DC Rating of Switch (A) 120V 240V 240V 480V 600V 125V 250V Poles Catalog Number Price 30 2 3 7.5 15 20 3 5 3 11-N30-1753 284 A2 60 3 10 15 30 40 5 10 3 11-N60-1753 384 B2 100 7.5 15 30 75 100 10 15 3 11-NU100-1753 725 F1 Dimension Code 30A & 60A Typical 200 ~ 50 75 150 200 15 15 3 11-NU200-1753 1620 F1 NU100A...1200A Typical 400 ~ ~ 125 250 350 20 50 3 11-NU400-1753 3071 F2 600 ~ ~ 200 400 350 20 50 3 11-NU600-1753 4299 F3 800 ~ ~ 200 500 500 ~ ~ 3 11-NU800-1753 6019 F4 1200 ~ ~ 200 500 500 ~ ~ 3 11-NU1200-1753 13241 F4 Updated 05-13-13 Ordering Instructions Specify Switch catalog number (this page) Specify desired switch handle catalog number (page 31) Specify desired operating shaft catalog number (page 32) Specify desired accessories (starting on page 33) ➊ Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower rating. ➋ Only U listed Class CC, J and CSA Certified HRCI-J fuses are suitable for use with these disconnect switches. ➌ Non-fused disconnect switches must use separately installed fuses for upstream short circuit protection. ➍ 30A U-rated device has Ithe of 40 A per IEC. 60A U-rated device has Ithe of 80A per IEC. ➎ To order a fusible switch with fuse status indicator on 30A and 60A switches, add an S to the end of the catalog number and apply adder from list below. For example, 11-J30-1753 @ $335 changes to 11-J30-1753S @ $349. For 11-C30/J30 Add $14.00 For 11-J60/H30/H60 Add $18.00 Not available on J100 J600, or 800 devices. 29 11

Series 11 Accessories 4th-Pole Modules (for 30A & 60A only) ➍ Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 240V 480V 600V 125V 250V Fuses Catalog Number Price U Class CC and CSA HRCI-MISC Fuses Dimension Code 30 2 3 7.5 15 20 3 5 30A CC, HRCI-Misc 11-30-NC 80 A1 U Class J and CSA HRCI-J Fuses 30 2 3 7.5 15 20 3 5 30A J, HRCI-J 11-30-NJ 80 A1 60 3 10 15 30 50 5 10 60A J, HRCI-J 11-60-NJ 100 B1 11-30-NJ CSA HRCII-C Fuses 30A 30 2 3 7.5 15 20 ~ ~ HRCII-C 60 3 10 15 30 50 ~ ~ Non-Fused 60A HRCII-C 11-30-NH 80 B1 11-60-NH 100 B1 30 ➋ 2 3 7.5 15 20 3 5 ~ 11-30-NN 64 A2 11-30-NN 60 ➌ 3 10 15 30 40 5 10 ~ 11-60-NN 84 B2 Items in Gray available by Special Order only. 4th-Pole Modules must be ordered separately and field installed to existing 11 Switch. 11-30-NN 11-N30-1753 11 Replacement Mounting Hardware Accessory Switch Dimension Description Code Pkg Qty Catalog Number Price (1) set screw, (1) shaft clip, and (2) #8 M4 screws A1, A2 2 11-30-HDWR 3.50 (1) set screw, (1) shaft clip, and (4) #8 M4 screws B1, B2 4 11-60-HDWR 5 (8) HM10 25mm bolts, (8) HM10 nuts, (16) M10 washers F1 1 11-HF-200-4U 257 (8) HM12 30mm bolts, (8) HM12 nuts, (16) M12 washers F2 1 11-HF-400-4U 406 (8) HM16 16mm bolts, (8) HM10 nuts F6 1 11-HF-250-3BDU 99 (8) HM8 16mm bolts, (8) HM8 washers, (6) HM10 35mm bolts, (6) M10 nuts, (12) M10 washers F7 1 11-HF-400-3BU 406 (8) HM12 30mm bolts, (8) HM12 nuts F8, F9 1 11-HF-800-3U 274 ➊ Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower rating. ➋ 30A U-rated device has Ithe of 40 A per IEC. ➌ 60A U-rated device has Ithe of 80A per IEC. 30 Discount Schedule B-5 ➍ To order a 4th pole module for 30A or 60A switches with fuse status indicator, add an S to the end of the catalog number and apply adder from list below. For example, 11-30-NC @ $80 changes to 11-30-NCS @ $94. For 11-30-NC/NJ Add $14.00 For 11-30-NH/60-NJ/NH Add $18.00 Not available on J100 J600, or 800 devices.

Series 11 Accessories Switch Handle Assemblies (accepts 3 Padlocks) Switch Handle Assembly ➊➋ Description For use with Color Degree of Protection Catalog Number Price 11-PY Padlockable Handle - Standard 80 x 114 mm Configurable for defeatable or non-defeatable ➌ 11-30 60A Black Type 3R, 3, 12, 4, 4X 11-PB 53 Red/Yellow Type 3R, 3, 12, 4, 4X 11-PY 53 11-PBT Padlockable Handle - Test Mode 80 x 114 mm Configurable for defeatable or non-defeatable ➌ 11-30 60A Black Type 3R, 3, 12, 4, 4X 11-PBT 56 Red/Yellow Type 3R, 3, 12, 4, 4X 11-PYT 56 Black Type 1, 3R, 12, 4, 4X IP66 10-HM4 104 Operating Handle Standard orientation with defeater 11-100 400A Red/Yellow Type 1, 3R, 12, 4, 4X IP66 10-HM4E 104 10-HM4 Operating Handle Standard orientation with defeater 11-600 1200A Black with light grey Type 1, 3R, 12, 4, 4X IP65 11-HM4-141 Red/Yellow Type 1, 3R, 12, 4, 4X IP65 11-HM4E- 141 11-HM4- Operating handle Standard orientation without defeater 11-600 1200A Black with light grey Type 1, 3R, 12, 4, 4X IP65 11-HM4-N2-141 Red/Yellow Type 1, 3R, 12, 4, 4X IP65 11-HM4E-N2-141 11-HM4-N2- OSHA ock Out/Tag Out Compliance (OTO) OSHA CFR36 Section 1910 mandates that disconnects be able to be locked out while in the OFF position during servicing. All 11 handles comply with this important safety requitement. Please see NFPA Article 430 for disconnect requirements of motor applications. 11 Discount Schedule B-5 ➊ Mounting screws included with Switch Handle Assembly. ➋ ockable in OFF position (and ON position with special modification). ➌ Switch handle can be field modified to be defeatable or non-defeatable. 31

Series 11 Accessories Metal Operating Shafts ➊ Shaft (typical) For use with handle type Operating Shaft ength mm (in) Catalog Number Price 11-S1 S2 11-P/11-P_T for 11-30 60A 10-HM for 11 100 400A 305 (12) 11-S1 22 533 (21) 11-S2 29 320 (12.6) 11-R7 51 580 (22.8) 11-R8 94 11-HM for fused 11 600 800A 320 (12.6) 11-R11 54 560 (22) 11-R12 75 11-R7 R8 11-R9 R12 11-HM for Non-fused 11 600 1200A 320 (12.6) 11-R9 65 560 (22) 11-R10 84 NFPA 79 Handle Kit - Internal handle that permits operation of the disconnect when the panel door is open, in compliance with NFPA79. Includes NFPA 79 internal operating handle with shaft ➋ 11-P/11-P_T 10-HM4 (11 fused 100 400A) 11-HM4_- (11 fused 600 800A) 305 (12) 11-N1 94 533 (21) 11-N2 101 320 (12.6) 11-HM4-NFPA1 252 560 (22) 11-HM4-NFPA3 252 320 (12.6) 11-HM4-NFPA2 252 560 (22) 11-HM4-NFPA4 252 Operating Shaft Accessories Accessory Description Switch Dimension Code Pkg Qty Catalog Number Price Operating Shaft Coupler - Used with 11-S1 and 11-S2 shafts to extend shaft length an additional 120 mm (4.75 in). A1, A2, B1, B2 1 10-SC1 43 11 ➊ See page 40.4 for Shaft dimensions. ➋ The 11-NU100 NU1200 Non-Fused switches do not have a means to be locked in the OFF position, therefore are not in compliance with NFPA79 and should not be used with 11-HM4-NFPA* handle kits. 32 Discount Schedule B-5 Updated 05-02-13

Series 11 Accessories Switch Padlock Accessory (for 30A & 60A only) ➊➎ Accessory Description Switch Dimension Code Pkg Qty Catalog Number Price Swith Padlock Accessory A1, A2, B1, B2 1 11-PA1 13 Replacement Fuse Carriers (for 30A & 60A only) Without Fuse Status Indication With Fuse Status Indication Accessory Description Pkg Qty Catalog Number Price Catalog Number Price 30A CC Fuse Carrier 1 11-C30-FC 25 11-C30-FCS 34 30A J Fuse Carrier 1 11-J30-FC 25 11-J30-FCS 34 Neon Fuse Status Indication 11-J30-FC 60A J Fuse Carrier 1 11-J60-FC 34 11-J60-FCS 44 30A CSA HRCII-C Fuse Carrier 1 11-H30-FC 25 11-H30-FCS 33 60A CSA HRCII-C Fuse Carrier 1 11-H60-FC 33 11-H60-FCS 44 30A Non-Fuse Carrier 1 11-N30-FC 22 11-J30-FCS Items in Gray are Special Order. 60A Non-Fuse Carrier 1 11-N60-FC 28 Auxiliary Contact Blocks Accessory Description For use with... Contact Material Contact Block ➋➌ Note: Sold only in multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces. Auxiliary Contact Block ➍ N.O./N.C. All 11-30 60A All Fusible switches 11-100 800A All 11 Non-Fused 100...1200A N.O. N.C. N.O.E.M. N.C..B. N.O. w/ spring-clamp N.CO. w/ spring-clamp 1 2 4 1 2 4 1 2 4 Pkg Qty 10 Catalog Number D7-X10 D7-X01 D7-X10E D7-X01 D7-Q10 D7-Q01 Price See Section H 1 11-1STNONC 15 1 11-2NDNONC 19 11 ➊ For Padlock with ø3 6mm. ➋ Also used for test mode function on 30A 60A switches. ➌ Maximum auxiliary contact blocks allowed to be mounted on switches: Max 6 for 30A 60A switches Max 4 for 11-J100 200A switches Max 8 for 11-J400 J600, & 800 switches Discount Schedule B-5 ➍ Only one auxiliary type can be mounted on switch. Auxiliaries cannot be combined. ➎ Fusible 11-100 800A has built in lockable feature on switch. 33

Series 11 Accessories Terminal Protective Covers ➊➋ Accessory Description No. of Poles Mounting Position Switch Dim. Code Qty req. per switch Pkg Qty Catalog Number Price 30A Terminal Shroud 3 60A Terminal Shroud 3 30A Terminal Shroud 1 60A Terminal Shroud 1 line or load side line or load side line or load side line or load side A1, A2 2 2 11-30-C3 10.50 B1, B2 2 2 11-60-C3 15.00 A1, A2 2 2 11-30-C1 4.50 B1, B2 2 2 11-60-C1 5.75 U Terminal Shroud for 11- U Fused 600A 800A U Terminal Shroud for 11- U Fused 200A U Terminal Shroud for 11 - U Fused 400A U Terminal Shield for 11-3 3 3 line or load side line or load side line or load side F17 2 3 11-NC29 113 F6 2 1 11-NC31 174 F7 2 1 11-NC32 115 U Non-fused 100A 200A 3 line side F1 1 1 11-NC17 34 3 load side F1 1 1 11-NC18 34 U Non-fused 400A 3 line side F2 1 1 11-NC20 83 3 load side F2 1 1 11-NC21 83 U Non-fused 600A 3 line or load F3 1 1 11-NC23 120 U Non-fused 800A 1200A 3 line or load F4 1 1 11-NC25 160 Multi-Tap Terminal ugs ➊ Accessory Description For 30A 11 Wire: (3) 8-14 AWG/1.5-10 mm 2 Torque: 14 lb-in/1.6 Nm For 60A 11 Wire: (3) 4-14 AWG/2-25 mm 2 Torque: 24 lb-in/2.8 Nm Switch Dimension Code Pkg Qty Catalog Number Price A1, A2 1 11-30-MT3 27 B1, B2 1 11-60-MT3 33 11 ➊ Includes integral plastic cover (not shown), for IP10 ingress rating only. ➋ Terminal Protective Covers shipped with 11 switches: 11-30 60A Optional 11-J100 400 Optional 11-J600 11-NC29 (3 pcs) 11-800 11-NC29 (3 pcs) 11-NU100 400 Optional 11-NU600 11-NC23 (1 pc) 11-NU800 1200 11-NC25 (1 pc) 33.1 Discount Schedule B-5

Series 11 Accessories Terminal ug Kits Accessory For use with Wire Size Pkg Qty Catalog Number Price 11 U Non-Fused 100 200A, Fused 200A (1) 300 MCM 3 11-T1 47 11 U Fused and Non-Fused 400A (1) 600 MCM 3 11-T3 160 11 U Fused and Non-Fused 400A (2) 350 MCM 3 11-T5 219 11 U Fused 600 800A and Non-Fused 600A (2) 600 MCM 3 11-T7 272 11 U Non-Fused 800 1200A (2) 600 MCM 6 11-T9 752 Cable-Operated Kits (for 30..60A switches) AVAIABE 2013 Accessory Description Cable length Catalog Number Price Cable-operated disconnect switch with handle Cable-operated disconnect kit with interlock Open switches Compatible with all 11 30A and 60A fused and non-fused disconnects (sold separately) Uses 11 handles (sold separately) IP66 (Type 3R, 3, 12, 4, 4X) Padlockable handle mounts to flange-styled enclosures Cable options available in 3 10 ft. lengths NFPA 2002 Compliant 3 ft 11-FC03 485 4 ft 11-FC04 489 6 ft 11-FC06 510 10 ft 11-FC10 524 Side-Mounted Switch Kit (for 30..60A switches) Accessory Description For use with... Catalog Number Price NFPA 79 Compliant IEC Fused and Non-Fused s, Side-Mounted Kit Used with all 30/60A fused and non-fused disconnects and 11-P handles (both sold separately) Open switches Operating handle ingress ratings: IP66 (Type 3R, 3, 12, 4, 4X) Padlockable handle AVAIABE 2013 11-SDK1 side-mount handle provides NFPA 79 compliancy with a bracketed switch and interlock system. The 11-P rotary handle is mounted to the side of the enclosure and attaches to the 11 next generation disconnect and interlock mechanism. The side handle remains connected to the switch and interlock mechanism at all times. This solution provides the single, side handle design with the NFPA 79 compliancy of the secondary interlock. This kit is used with the 11-P family of disconnect handles (sold separately). 11 30/60A disconnect switches and 11-P handles 11-SDK1 164 11 Updated 03-21-13 Discount Schedule B-5 33.2

Series 11 11 Enclosed Motor s (U and CSA Approved Enclosures) Type 3/4/12 Watertight, Dusttight Sheetmetal Enclosure Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure Type 4/4X Watertight, Corrosion-Resistant Non-metallic Enclosure Amp/Horsepower Rating U/ CSA Amps 1Ø (60 Hz) Horsepower 3Ø (60 Hz) Dimension Code 120V 240V 240V 480V 600V Catalog Number Price Catalog Number Price Catalog Number Price Class CC Fused Dimension Code Dimension Code 30 2 3 7.5 15 20 11-FC030P3 827 A1 11-CC030P3 1197 A1 11-KC030P3 830 A1 Class J Fused 30 2 3 7.5 15 20 11-FJ030P3 847 A1 11-CJ030P3 1217 A1 11-KJ030P3 850 A1 60 3 10 15 30 50 11-FJ060P3 1053 B1 11-CJ060P3 1398 B1 11-KJ060P3 1053 B1 100 7.5 15 30 60 75 11-FJ100P3 1433 C1 11-CJ100P3 2629 C1 11-KJ100P3 1433 C1 200 ~ 25 60 125 150 11-FJ200P3 2390 D1 11-CJ200P3 3695 D1 11-KJ200P3 2389 D1 400 ~ 50 125 250 350 11-FJ400P3 4402 F1 11-CJ400P3 7064 F1 11-KJ400P3 4401 F1 Non-Fused 30 2 3 7.5 15 20 11-FN030P3 561 A2 11-CN030P3 1056 A2 11-KN030P3 561 A2 60 3 10 15 30 50 11-FN060P3 993 B2 11-CN060P3 1337 B2 11-KN060P3 993 B2 100 7.5 15 30 75 100 11-FN100P3 1433 C1 11-CN100P3 2629 C1 11-KN100P3 1433 C1 200 ~ 50 75 150 200 11-FN200P3 2390 D1 11-CN200P3 3695 D1 11-KN200P3 2389 D1 400 ~ ~ 125 250 350 11-FN400P3 4402 F1 11-CN400P3 7064 F1 11-KN400P3 4401 F1 NOTE: All Enclosed s come standard with a black handle with ON/OFF marking. For a yellow and red handle, add suffix E to the end of the catalog number. Example: change 11-FN030P3 to 11-FN030P3E. 11 arger sizes available. Contact your Sprecher + Schuh representative. 11-KJ060P3 34

Application Methods Series 11 Applications Within the United States and Canada General The requirements for disconnect switches used in motor branch circuits rated 600V and less are defined in Article 430, Part J of the U.S. National Electrical Code (NEC), NFPA70. Canadian Electrical Code (CEC) requirements are very similar in the area of motor branch circuit disconnect requirements. For simplicity, we will treat the NEC and CEC requirements as being the same and reference specific sections of the US National Electrical Code. The requirements for properly sizing a disconnect switch are dependent on the type of application. The NEC refers to two types of applications: single motor and combination loads. A combination load consists of an application where two or more motors are used together or where one or more motors are used in combination with other loads, such as resistance heaters. Single Motor Applications Section 430-110 Paragraph (a) states that the disconnect switch must have an ampere rating of at least 115% of the full load current rating of the motor. Example 1: for a motor with a full-load current of 22A, the disconnect switch must be rated at least 25.3A (22 x 1.15). current is the sum of the simultaneously started motors locked-rotor currents and the full-load currents of the remaining operating motor and non-motor loads. The disconnecting means shall have a current rating equal to or greater then 115% of the equivalent single motor full-load current and have a horsepower rating equal to or greater than the horsepower rating determined from the equivalent locked-rotor summation. Consider the following 460V application: oad HP Full-oad Current A Motor 1 5 7.6 (simultaneous) Motor 2 10 14.0 (not included) ➊ Motor 3 15 21.0 (simultaneous) Motor 4 20 27.0 (simultaneous) Other 7.0 (simultaneous) Total Equivalent 62.6 (simultaneous) ➊ Motor 2 is not included in the total since it cannot operate simultaneously with the other motor, therefore, the disconnect switch must be rated at least 72A (1.15 x 62.6). If the disconnecting means under evaluation is rated in horsepower, the selection of the disconnect switch is even more straightforward; a disconnect switch must have a horsepower rating equal to, or greater than the horsepower rating of the motor at the applicable voltage. Example 2: For a motor with a 10HP rating at 460V AC, the disconnect switch must be rated at least 10HP at 460V AC. If the disconnect switch is rated in horsepower, and U isted, U Component Recognized, or CSA Certified, it will meet the requirements for the 115% full-load current rating stipulated by the NEC. Combination oad Applications Section 430-110 Paragraph (c) addresses the rating of the disconnecting means for combination loads. This paragraph essentially requires that the loads that may be simultaneously on a single disconnecting means be combined to provide equivalent full-load and locked-rotor currents for what is then to be considered as a single motor for the purpose of selecting the appropriate disconnecting means. This means that it is necessary to identify the particular combination of connected loads which can be operating simultaneously and will result in the maximum full-load and locked-rotor current sums. The individual full-load current values are to be selected from Tables 430-148, 430-149, or 430-150 and the locked-rotor values are to be from Table 430-151. The equivalent single motor full-load current is the sum of the simultaneously operating motor full-load currents and the rating in amperes of the other loads operating at the same time. The equivalent locked-rotor Consider now the locked-rotor current analysis for the same application: oad HP ocked Rotor Current A Motor 1 5 (7.6 FA) 45.6 (simultaneous) Motor 2 10 84.0 (not included) ➊ Motor 3 15 126.0 (simultaneous) ➋ Motor 4 20 162.0 (simultaneous) ➋ Other 7.0 (simultaneous) Total Equivalent 302.6 (simultaneous) ➊ Note again that Motor 2 cannot operate simultaneously with the other loads. ➋ The largest equivalent locked-rotor current occurs when motors 3 and 4 start together while the other loads marked simultaneous are already operating. Since Motor 1 is not starting with Motors 3 and 4, its full-load current will be added to the total instead of its locked-rotor current. Table 430-151, which provides the correlation between locked-rotor currents and HP ratings, shows that a 40 HP rating is the equivalent for 302.6 locked-rotor amperes. Therefore, the disconnect selected for this application must have a current rating of at least 72A and a HP rating of at least 40 HP. In this case, an 10 disconnect switch rated for 100A and 60 HP at 460V would be an appropriate choice. What can be seen from this analysis is that, depending upon the number of motors that can start simultaneously, the actual size of the required disconnect is sometimes determined by the equivalent full load current (72A) and other times by the equivalent horsepower determined from the locked-rotor analysis (40 HP). 34.1 11

Technical Information IP Ratings Definitions IP Ratings Definitions IP Ratings Definitions The first IP number (left side of chart) is protection against solid objects. The second IP number (across top) is protection against liquids. The chart itself shows degrees of protection according to IEC 529. No protection Protected against vertically falling drops of water (condensation) Protected against dripping water with enclosure up to 15 from vertical Protected against sprayed water up to 60 from vertical Protected against sprayed water from all directions (limited ingress permitted) Protected against low pressure water jets from all directions (limited ingress permitted) Protected against strong jets of water from all directions Protected against immersion up to one meter Protected against long periods of immersion under pressure IP 0 IP 1 IP 2 IP 3 IP 4 IP 5 IP 6 IP 7 IP 8 1 meter IP0 IP00 No protection IP1 Protected against solid objects up to 50mm (accidental touch by hands) IP2 Protected against solid objects up to 12mm (fingers, knuckles) IP3 IP10 IP11 IP12 IP20 IP21 IP22 IP23 IP30 IP31 IP32 IP33 IP34 11 Protected against solid objects up to 2.5mm (tools, wires) IP4 Protected against solid objects up to 1mm (wires) IP5 Protected against dust (limited engress permitted) IP6 IP40 IP41 IP42 IP43 IP44 IP50 IP53 IP54 IP55 IP56 IP60 IP65 IP66 IP67 Totally protected against dust 34.2

Technical Information Ratings Definitions NEMA / U Type Definitions NEMA / U Type Indoor Use Outdoor Use Indoor or Outdoor Use For a degree of protection against: 1 12 13 3R 3 4 4X 6P 6 Incidental contact with enclosed equipment Falling dirt Rust Circulating dust, lint, fibers and flyings Windblown dust Falling liquids and light splashing Rain (limited water allowed inside) Rain (no water allowed inside) Snow and sleet Hosedown and splashing water Occasional prolonged submersion Oil or coolant spraying or splashing Corrosive agents Occasional temporary submersion 11 34.3

Technical Information Series 11 Fused for U Class Fuses and CSA HRCI-J Electrical Ratings 11-C30-1753 11-J30-1753 11-J60-1753 U Fuse Type / CSA Fuse Type Class CC/HRCI- MISC ➊ Class J/HRCI-J Class J/HRCI-J Maximum Fuse Cartridge Size (A) 30 30 60 Maximum Voltage AC DC (V) (V) Ampere Rating (A) 30 30 60 Maximum Short Circuit Prospective Fault Current (ka) 200 200 200 Fuse Operating Characteristics Time Delay 600 250 Non- Time Delay Time Delay 600 250 Non- Time Delay Time Delay Maximum Hp, 3Ø AC 200V 60 Hz (Hp) 5 3 7.5 3 15 7.5 240V 60 Hz (Hp) 5 3 7.5 3 15 7.5 480V 60 Hz (Hp) 10 5 15 5 30 15 600V 60 Hz (Hp) 10 7.5 20 7.5 50 15 Maximum Hp, 1Ø AC 120V, 60 Hz (Hp) 0.75 0.5 2 0.5 3 1.5 240V, 60 Hz (Hp) 2 1.5 3 1.5 10 3 Maximum Hp, DC 125V, DC (Hp) 2 3 3 2 5 5 250V, DC (Hp) 3 5 5 5 10 10 600 250 Non- Time Delay Mechanical Data 11-C30-1753 11-J30-1753 11-J60-1753 Degree of Protection (per IEC 60947-3) Switch Only IP20 IP20 IP20 Switch with Terminal Shield & Fuse Carriers IP20 IP20 IP20 Mechanical Endurance ➋ Operations 10,000 10,000 10,000 Handle Mechanism Operating Torque N m lb in Terminal Capacity Power Terminals mm 2 2.5 10 2.5 10 2.5 25 AWG #14 #8 #14 #8 #14 #4 Auxiliary Contact Terminals mm 2 2.5 4 2.5 4 2.5 4 AWG #14 #12 #14 #12 #14 #12 Maximum Number of Auxiliary Contacts 6 6 6 Approximate Weight kg 0.92 0.92 1.32 lbs 2.03 2.03 2.9 Minimum Enclosure Size Height 248 (9-3/4) 248 (9-3/4) 248 (9-3/4) Approximate dimensions in Width 171 (6-3/4) 171 (6-3/4) 197 (7-3/4) millimeters (inches) Depth 148 (5-13/16) 148 (5-13/16) 148 (5-13/16) Switch Dimensions Reference (See dimension drawings) A1 A1 B1 3.5 35 3.5 35 3.5 35 11 Updated 03-21-13 ➊ CSA HRCI-MISC fuses must also be U isted as Class CC fuses. ➋ Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 60947-3, and U 98. 35

Technical Information Series 11 Fused for U Class Fuses and CSA HRCI-J Electrical Ratings 11-J100-1753 11-J200-1753 11-J400-1753 11-J600-1753 11-800-1753 U Fuse Type / CSA Fuse Type Class J/HRCI-J Class Maximum Fuse Cartridge Size (A) 100 200 400 600 800 Maximum Voltage AC DC (V) (V) 600 250 ➋ 600 250 ➋ 600 250 ➋ 600 250 ➋ Ampere Rating (A) 100 200 400 600 800 Maximum Short Circuit Prospective Fault Current (ka) 200 200 200 200 200 Fuse Operating Characteristics Maximum Hp, 3Ø AC 200V 60 Hz (Hp) ~ ~ ~ ~ ~ 240V 60 Hz (Hp) 30 60 125 200 200 480V 60 Hz (Hp) 60 125 250 400 500 600V 60 Hz (Hp) 75 150 350 500 500 Maximum Hp, 1Ø AC 120V, 60 Hz (Hp) 7.5 ~ ~ ~ ~ 240V, 60 Hz (Hp) 15 25 50 ~ ~ Maximum Hp, DC 125V, DC (Hp) 7.5 15 20 ~ ~ 250V, DC (Hp) 20 40 50 ~ ~ 600 250 ➋ 11 Mechanical Data 11-J100-1753 11-J200-1753 11-J400-1753 11-J600-1753 11-800-1753 Degree of Protection (per IEC 60947-3) Switch Only IP20 IP20 IP20 IP20 IP20 Switch with Terminal Shield & Fuse Carriers IP20 IP20 IP20 IP20 IP20 Mechanical Endurance ➊ Operations 10,000 8,000 6,000 5,000 5,000 Handle Mechanism Operating Torque N m lb in 10 88.5 Terminal Capacity 600 MCM; 2 x Power Terminals mm 2 300 MCM 300 MCM 2 x 600 MCM 2 x 600 MCM AWG #1 #6 #2 or 2 x #6 2 x #2 2 x #2 Auxiliary Contact Terminals mm 2 2.5 4 2.5 4 2.5 4 2.5 4 2.5 4 AWG #14 #12 #14 #12 #14 #12 #14 #12 #14 #12 Maximum Number of Auxiliary Contacts 4 8 8 8 8 Approximate Weight kg 2.4 3.6 4.85 20 20 lbs 5.3 7.9 10.7 44 44 Minimum Enclosure Size Height Approximate dimensions in Width ~ ~ ~ ~ ~ millimeters (inches) Depth Switch Dimensions Reference (See dimension drawings) F5 F6 F7 F8 F9 15 132.8 20 177 70 620 70 620 ➊ Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 60947-3. ➋ 3-Poles in series. 36 Updated 05-13-13

Technical Information Series 11 Non-Fused for CSA and U Class Applications ➊ Electrical Ratings 11-N30-1753 11-N60-1753 11-NU100-1753 11-NU200-1753 Maximum Voltage AC DC (V) (V) 600 250 Fuse Type ~ ~ J J Ampere Rating (A) 30 ➋ 60 ➋ 100 200 Maximum Short Circuit Prospective Fault Current (ka) 200 200 200 200 Fuse Operating Characteristics ➌ Time Delay Non- Time Delay Time Delay 600 250 Non- Time Delay 600 250 600 250 ~ ~ Maximum Hp, 3Ø AC 200V 60 Hz (Hp) 7.5 3 15 7.5 ~ ~ 240V 60 Hz (Hp) 7.5 3 15 7.5 30 75 480V 60 Hz (Hp) 15 5 30 15 75 150 600V 60 Hz (Hp) 20 7.5 50 15 100 200 Maximum Hp, 1Ø AC 120V, 60 Hz (Hp) 2 0.5 3 1.5 7.5 ~ 240V, 60 Hz (Hp) 3 1.5 10 3 15 50 Maximum Hp, DC 125V, DC (Hp) 3 2 5 5 10 15 250V, DC (Hp) 5 5 10 10 15 15 Power ost (W) 2 6 ~ ~ Mechanical Data 11-N30-1753 11-N60-1753 11-NU100-1753 11-NU200-1753 Degree of Protection (per IEC 60947-3) Switch Only IP20 IP20 IP20 IP20 Switch with Terminal Shield & Fuse Carriers IP20 IP20 IP20 IP20 Mechanical Endurance ➌ Operations 10,000 10,000 10,000 10,000 Handle Mechanism Operating Torque Terminal Capacity N m lb in 3.5 35 Power Terminals mm 2 2.5 10 2.5 25 300 MCM 300 MCM AWG #14 #8 #14 #4 #6 #6 Auxiliary Contact Terminals mm 2 2.5 10 2.5 25 AWG #14 #8 #14 #4 ~ ~ Maximum Number of Auxiliary Contacts 6 6 2 2 Approximate Weight kg 0.81 1.14 1.67/2.1 1.67/2.1 lbs 1.78 2.52 3.7/4.3 3.7/4.3 Minimum Enclosure Size Height 248 (9-3/4) 248 (9-3/4) Approximate dimensions in Width 171 (6-3/4) 197 (7-3/4) ~ ~ millimeters (inches) Depth 111 (4-3/8) 111 (4-3/8) Switch Dimensions Reference (See dimension drawings) A2 B2 F1 F1 3.5 35 10 88.5 10 88.5 11 Updated 03-21-13 ➊ Non-fused disconnect switches must be used with separately installed fuses. ➋ When using CSA HRCI-J, HRCI-MISC (also U isted as Class CC) or HRCI-T fuses, and U Class J, CC or T fuses. ➌ Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 60947-3, U 1087 and U 98. 37

Technical Information Series 11 Non-Fused for CSA and U Class Applications ➊ Electrical Ratings 11-NU400-1753 11-NU600-1753 11-NU800-1753 11-NU1200-1753 Maximum Voltage AC DC (V) (V) 600 250 Fuse Type J J Ampere Rating (A) 400 600 800 1200 Maximum Short Circuit Prospective Fault Current (ka) 200 200 100 100 Fuse Operating Characteristics ➌ ~ ~ ~ ~ Maximum Hp, 3Ø AC 200V 60 Hz (Hp) ~ ~ ~ ~ 240V 60 Hz (Hp) 125 200 200 200 480V 60 Hz (Hp) 250 400 500 500 600V 60 Hz (Hp) 350 350 500 500 Maximum Hp, 1Ø AC 120V, 60 Hz (Hp) ~ ~ ~ ~ 240V, 60 Hz (Hp) ~ ~ ~ ~ Maximum Hp, DC 125V, DC (Hp) 20 20 ~ ~ 250V, DC (Hp) 50 50 ~ ~ Power ost (W) ~ ~ ~ ~ 600 250 600 250 600 250 11 Mechanical Data 11-NU400-1753 11-NU600-1753 11-NU800-1753 11-NU1200-1753 Degree of Protection (per IEC 60947-3) Switch Only IP20 IP20 IP20 IP20 Switch with Terminal Shield & Fuse Carriers IP20 IP20 IP20 IP20 Mechanical Endurance ➌ Operations 6,000 6,000 3,500 3,500 Handle Mechanism Operating Torque Terminal Capacity N m lb in 14.5 128.3 37 327.5 Power Terminals mm 2 600 MCM 2 x 600 MCM 4 x 600 MCM 4 x 600 MCM AWG #2 2 x #2 4 x #2 4 x #2 mm Auxiliary Contact Terminals AWG ~ ~ ~ ~ Maximum Number of Auxiliary Contacts 2 2 2 2 Approximate Weight kg 3/3.8 8.2/10.3 11.6/14.5 11.6/14.5 lbs 6.6/8.4 18.1/22.7 25.6/32 25.6/32 Minimum Enclosure Size Height Approximate dimensions in Width ~ ~ ~ ~ millimeters (inches) Depth Switch Dimensions Reference (See dimension drawings) F2 F3 F4 F4 50 442 50 442 ➊ Non-fused disconnect switches must be used with separately installed fuses. ➋ When using CSA HRCI-J, HRCI-MISC (also U isted as Class CC) or HRCI-T fuses, and U Class J, CC or T fuses. ➌ Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 60947-3, U 1087 and U 98. 37.1 Updated 03-21-13

Technical Information Series 11 Fused for CSA HRCII-C Fuses Electrical Ratings 11-H30-1753 11-H60-1753 CSA Fuse Type/U Fuse Type HRCII-C HRCII-C Maximum Fuse Cartridge Size (A) 30 60 Maximum Voltage AC (V) 600 600 Ampere Rating (A) 30 60 Maximum Short Circuit Prospective Fault Current (ka) 200 200 Fuse Operating Characteristics Maximum Hp, 3Ø AC 200V 60 Hz (Hp) 7.5 15 240V 60 Hz (Hp) 7.5 15 480V 60 Hz (Hp) 15 30 600V 60 Hz (Hp) 20 50 Maximum Hp, 1Ø AC 120V, 60 Hz (Hp) 2 3 240V, 60 Hz (Hp) 3 10 Mechanical Data 11-H30-1753 11-H60-1753 Degree of Protection (per IEC 60947-3) Switch Only IP20 IP20 Switch with Terminal Shield & Fuse Carriers IP20 IP20 Mechanical Endurance ➊ Operations 10,000 10,000 Handle Mechanism Operating Torque N m lb in Terminal Capacity Power Terminals mm 2 2.5 10 2.5 25 AWG #14 #8 #14 #4 Auxiliary Contact Terminals mm 2 2.5 4 2.5 4 AWG #14 #12 #14 #12 Maximum Number of Auxiliary Contacts 6 6 Approximate Weight kg 1.18 1.18 lbs 2.60 2.60 Minimum Enclosure Size Height 248 (9-3/4) 248 (9-3/4) Approximate dimensions in Width 171 (6-3/4) 197 (7-3/4) millimeters (inches) Depth 148 (5-13/16) 148 (5-13/16) Switch Dimensions Reference (See dimension drawings) B1 B1 3.5 35 3.5 35 11 Updated 03-21-13 ➊ Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 60947-3, U 1087 and U 98. 37.2

Technical Information Series 11 Environmental Data For All 11 Fused and Non-Fused Environmental Ratings 11-_30A 60A 11-_100A 1200A ➊ Ambient Temperature Open [ C (F)] 20 +55 ( 4 +131) 20 +70 ( 4 +158) Enclosed [ C (F)] 20 +40 ( 4 +104) 20 +70 ( 4 +158) Storage [ C (F)] 40 +65 ( 40 +149) 25 +70 ( 13 +158) Altitude (per IEC 60947-1) [m] 2,000 2,000 Relative Humidity (per IEC 60947-1) 90% at +20 C (+68 F) 90% at +20 C (+68 F) 50% at +40 C (+104 F) 50% at +40 C (+104 F) Standards Compliance IEC 60947-4-1/EN60947-3 BS EN60947-3 VDE 0660 CSA 22.2 No. 4 NEMA KS-1 U 98 with 11-SDK1 Handle Kit U 98 CSA 22.2 No. 4 Certifications U isted (File No. E 47426, Guide WHTY) CSA Certified (File No. R1234) CE ASTA Certified OVAG Certified with 11-SDK1 Handle Kit U isted (File No. E47426, Guide WHTY) CSA Certified (File No. R1234) CSA HRCII Fuses (sold by others) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 11 CSA fuse type: HRCII-C Voltage rating: 600V AC Interrupting rating: 200 000 A Standard cartridge sizes: 30, & 60 A Typical ampere ratings: 1 60 A Construction: Blade type for bolted connection Can be installed on Bulletin 194R disconnect switch Cat. Nos: 11-H30-1753, 11-H60-1753 Where used: Canada Current Range [A] A B C D E F G H J 0 30 84.14 (3-5/16) 71.04 (2-51/64) 50.8 (2) 20.64 (13/16) 8.73 (11/32) 7.54 (19/64) 5.56 (7/32) 23.81 (15/16) 1.59 (1/16) 31 60 88.9 (3-1/2) 71.04 (2-51/64) 50.8 (2) 20.64 (13/16) 12.7 (1/2) 7.54 (19/64) 5.56 (7/32) 26.99 (1-1/16) 1.59 (1/16) ➊ Derate switch 1% for every 1ºC over 40ºC 37.3 Updated 03-26-13

Technical Information Series 11 CSA HRCI Class CC Fuses (sold by others) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. U fuse type: Class CC CSA fuse type: HRCI-MISC Voltage rating: 600V AC Interrupting rating: 200 000 A Standard cartridge sizes: 30 A Typical ampere ratings: 1 30 A Construction: Ferrule type Can be installed on 11-C30-1753 disconnect switch Where used: North America CSA HRCI Class J Fuses (sold by others) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. CSA fuse type: HRCI-J U fuse type: Class J Voltage rating: 600V AC Interrupting rating: 200 000 A Standard cartridge sizes: 30, 60, 100, 200, and 400 A Typical ampere ratings: 1 600 A; Blade type for bolted connection Can be installed on 11 disconnect switch Cat. Nos: 11-J30 J400-1753 Where used: North America 27 11 37.4

Technical Information Series 11 Wiring Diagrams U isted, CSA Certified Dimension Reference Circuit 11-C30-1753 11-J30-1753 11-J60-1753 11-H30-1753 11-H60-1753 A1 A1 B1 B1 B1 11-N30-1753 11-N60-1753 A2 B2 11- -1753 + 11- -NC/NJ/NH 3-Pole Switch + 4-Pole Module 11 38

Dimensions Series 11 11 Fused and Non-Fused (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. D W FD 11 A E H C B Dimension Approximate Dimensions in mm (in) Reference H W D A B C ➊ E ➊ FD A1 108 (4-1/4) 120 (4-3/4) 101 (4) 90 (3-9/16) 105 (4-1/8) 85 (3-11/32) 82 (3-15/64) 2-M4, 2-#8 A2 108 (4-1/4) 120 (4-3/4) 80 (3-1/8) 90 (3-9/16) 105 (4-1/8) 85 (3-11/32) 82 (3-15/64) 2-M4, 2-#8 B1 113 (4-29/64) 142 (5-19/32) 114 (4-31/64) 100 (3-15/16) 120 (4-23/32) N/A N/A 4-M4, 4-#8 B2 113 (4-29/64) 142 (5-19/32) 93 (3-43/64) 100 (3-15/16) 120 (4-23/32) N/A N/A 4-M4,4-#8 ➊ Mounting holes are backward compatible with 10 39

Dimensions Series 11 11 Fused (100A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 5.87 149.3 1.41 36 1.46 37.2 1.41 36 4.81 122.2 11 7.32 186 6.77 172 5.23 133 11 Fused (200A) 7.72 196.2 6.61 168 6.18 157 5.28 134.2 6.50 165.2 7.67 195 11.46 291.3 1.41 36 5.11 130 1.96 50 40

Dimensions Series 11 11 Fused (400A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 7.08 180 4.37 111.1 10.19 ( 3P) - 12.79 (4P) 259 (3P) - 325 (4P) 3.98 101.25 7.97 202.5 15.35 390 9.44 240 3.98 101.25 2.95 75 0.98 24.9 2.95 75 3.26 83 2.59 66 2.59 66 11 Fused (600 800A) min 10.43 min 265 9.84 250 6.10 155 11.18 (3P) - 14.88 (4P) 284 (3P) - (4P) 2.56 1.34 65 34 3.12 79.5 3.36 85.5 0.43 11 14.96 380 0.27 7 2.32 59 0.27 7 0.27 7 11.81 300 3.54 90 11.81 300 3.36 85.5 10.23 260 9.84 250 5 126.5 Ø 0.5 1 Ø 13 2 51 3.7 3.7 94 94 14.33 (3P) - 18.03 (4P) 364 (3P) - 458 (4P) 0.35 9 18.54 471 11 40.1

Dimensions Series 11 11 Non-Fused (100 400A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. M J1 U Z Y Terminal Shrouds W R1 H N AA AC V K AB R2 T F AD C 11 11-N 100 200 Dim. Ref. F1 400 F2 11-N 100 200 Dim. Ref. F1 400 F2 Overall Approximate Dimensions in mm (in) Terminal Shrouds Switch Body Switch Mounting C AC AD F (3-pole) 94.6 (3.72) 94.6 (3.72) 128 (4.92) 256 (10.1) 256 (10.1) 406 (16) 77.5 (3.05) 77.5 (3.05) 115 (4.15) 180 (7.09) 180 (7.09) 230 (9.05) F (4-pole) 230 (9.06) 230 (9.06) 290 (11.4) H 107 (4.22) 107 (4.22) 166 (6.53) Approximate Dimensions in mm (in) Connection J1 (3-pole) 55 (2.17) 55 (2.17) 75 (2.95) J1 (4-pole) 105 (4.13) 105 (4.13) 135 (5.31) T U V W Y Z AA AB 50 (1.97) 50 (1.97) 65 (2.56) 25 (0.98) 25 (0.98) 45 (1.77) 30 (1.18) 30 (1.18) 50 (1.97) 11 (0.43) 11 (0.43) 13 (0.51) 3.5 (0.14) 3.5 (0.14) 5 (0.2) 34.4 (0.14) 34.4 (0.14) 53 (2.08) 160 (6.3) 160 (6.3) 260 (10.2) 15 (0.6) 15 (0.6) 20 (0.8) K 45.6 (1.8) 45.6 (1.8) 67.5 (2.65) M (3-pole) 160 (6.3) 160 (6.3) 210 (8.26) M (4-pole) 210 (8.7) 210 (8.7) 270 (10.6) N R1 R2 135 (5.31) 135 (5.31) 195 (7.67) 9 (0.35) 9 (0.35) 9 (0.35) 7 (0.27) 7 (0.27) 7 (0.27) 40.2 Updated 05-02-13

Dimensions Series 11 11 Non-Fused (600A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. H Z J M Ø 0.5 1 Ø 13 Y X AC N N1 AA 3.15 80 F 11-N Dim. Ref. 600 F3 Approximate Dimensions in mm (in) Terminal Shrouds Switch Body Switch Mounting Connection AC F (3-pole) F (4-pole) H J (3-pole) J (4-pole) M (3-pole) M (4-pole) N N1 AA Z 460 280 360 140 127.5 167.5 255 335 175 59.5 320 47 (18.12) (11) (14.17) (5.5) (5) (6.59) (10.03) (13.19) (6.88) (2.34) (12.6) (1.85) H Z 11 Non-Fused (800 1200A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 0.78 20 1.57 40 Ø 0.43 Ø 11 J M AA AC 0.78 20 Y X N1 N2 N AA 8.85 225 4.72 120 F 11 11-N 800 1200 Dim. Ref. F4 Approximate Dimensions in mm (in) Terminal Shrouds Switch Body Switch Mounting Connection AC F (3-pole) F (4-pole) H J (3-pole) J (4-pole) M (3-pole) M (4-pole) N N1 AA Z 460 372 492 140 173.5 233.5 347 467 175 59.5 330 47 (18.12) (14.64) (19.37) (5.5) (6.83) (9.19) (13.66) (18.38) (6.88) (2.34) (13) (1.85) 460 372 492 140 173.5 233.5 347 467 175 59.5 330 47 (18.12) (14.64) (19.37) (5.5) (6.83) (9.19) (13.66) (18.38) (6.88) (2.34) (13) (1.85) 40.3

Dimensions Series 11 Handles 11 Metal Operating Shaft Dimensions 11-S1..S2 11-R7..R8 11-R9..R12 A A B C Catalog Number A 2 mm (in) B mm (in) C mm (in) 11-S1 6.35 (0.238) 305 (12) 11-S2 6.35 (0.238) 533 (21) 11-R7 10 (0.39) 320 (12.6) ~ 11-R8 10 (0.39) 580 (22.8) ~ 11-R9 12 (0.47) 320 (12.6) 22 (0.87) 11-R10 12 (0.47) 560 (22) 22 (0.87) 11-R11 12 (0.47) 320 (12.6) 22 (0.87) 11-R12 12 (0.47) 560 (22) 22 (0.87) Typical View 11-P*/11-P*T Operating Handles Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 1.2 4.8 mm (0.05 0.19) 80 (3.15) 114 (4.49) 72.3 (2.85) 26.7 (1.05) 25.4 (1) 11 Fron t of Cover ø 35 (ø 1.38) 76.7 (3.02) Front 34 (1.34) 50 (1.97) 25 (0.98) 25 (0.98) 50 (1.97) 51 (2.01) Right Side OR 25 (0.98) ø 35 (ø 1.38) 31.5 (1.24) 63 (2.48) (2) - ø 5.5 (0.22) (2) - ø 5.5 (0.22) 40.4

Dimensions Series 11 Handles 10-HM4/HM4E Operating Handles dia. dia. Operating Handles Cat. No. 10-HM4, -HM4E 11-HM4*-/-N2- Operating Handles Ø 78 (3.07) 0 90 I 4 Ø 7 (0.27) Ø 37 (1.46) 20 (0.78) 210 (8.27) 14 (0.55) 14 (0.55) 20 (0.78) 11 61 (2.40) 40.5

Dimensions Series 11 Handles 11-N1 & 11-N2 Operating Handle (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. C 1 C C - D 2 3 Next Generation 11 egacy 10 C D C D 11-N30- > 165 mm 6.5 in 10-NN030 > 170 mm 6.75 in 11-B20-11-B32-11-C30-11-F25-11-F32-11-J30- > 190 mm 7.5 in 155 mm 6.0 in 10-NC030 10-NJ030 10-NA100 10-NA200 > 210 mm 8.25 in 140 mm 5.5 in 11-N60- > 180 mm 7.0 in 10-NN060 > 170 mm 6.75 in 11-B63-11-D32-11-D63-11-F63-11-H30-11-H60-11-J60- > 205 mm 8.0 in 170 mm 6.75 in 10-NJ060 10-NA300 > 210 mm 8.25 in 115 mm 4.5 in 11 40.6

AVAIABE 2013 Dimensions Series 11-FC_ Cable-Operated Handle 11-FC NFPA79 Cable-Operated Handle The 11-FC cable-operated disconnect with interlock provides a fully compliant solution to the 2002 changes in the National Fire Protection Association 79 (NFPA 79). The 11-FC combines the small size of the 11 IEC disconnect with the flexibility of a cable-operated mechanism to provide an NFPA 79 IEC solution for flange style enclosures. The 11-FC bracketed mechanism for 11 30 and 60 A devices attaches to the 11 disconnect switch base and operates the ON-OFF action via cable to a standard 10/11 handle. The 11-FC handle/interlock mechanism provides the no-tools operation and the secondary interlock as required by NFPA 79 2002 changes. The 11-FC cable-operated disconnect is offered in 3 10 ft cable lengths, allowing a variety of placement options for the 11 disconnect within the enclosure. The handle (ordered separately) is available in 3 different styles: plastic, stainless steel, or painted metal. Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 152.4 (6) 123.8 (4-7/8) mm (in.) 100 (3-15/16) 203.2 (8) Ref. 250.4 (10) Min. 11 40.7

AVAIABE 2013 Dimensions Series 11-SDK1 Side-Mounted Handle 11-SDK1 Side Mounted Handle The 11-SDK1 side-mount handle provides NFPA 79 compliancy with a bracketed switch and interlock system. The 10-HS rotary handle is mounted to the side of the enclosure and attaches to the 11 disconnect and interlock mechanism. The side handle remains connected to the switch and interlock mechanism at all times. This solution provides the single, side handle design with the NFPA 79 compliancy of the secondary interlock. This kit is used with the 10-HS family of disconnect handles (sold separately). Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. Hinge Side 38.1 (1-1/2) Enclosure Thickness mm (in) 15.9 (ø 9/16) 88.4 (3-31/64) 31.8 (1-1/4) 152.4 Min. (6) 25 (63/64) 6.4 (1/4) 5.6 ø (ø 7/32) 2 Holes 22.2 (7/8) C Door Hook Defeater ever Interlock 5.6 ø (ø 7/32) 6 Holes 63.5 (2-1/2) 88.9 (3-1/2) 44.4 (1-3/4) 25 (63/64) 34.9 (ø 1-3/8) 50 (1-31/32) 50.8 (2) 101.6 (4) 208.5 (8-7/32) Ref. 50 (1-31/32) 89.4 (3-33/64) Hinge Side 51 (2.01) Door Hook 11 11-P* Handle 40.8

Dimensions Series 11 11 Enclosure and Operating Handle Dimensions Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. A 51 (2.01) C B F E D Catalog Number 11-C30-1753 11-J30-1753 Dimension Reference A B C D E F Maximum Minimum Minimum Maximum Minimum Minimum Minimum Maximum A1 171 (6-3/4) 45 (1-49/64) 147.6 (5-13/16) 454 (17-7/8) 248 (9-3/4) 89 (3-1/2) 1.4 (1/16) 4/78 (3/16) 11-N30-1753 A2 171 (6-3/4) 45 (1-49/64) 111 (4-3/8) 454 (17-7/8) 248 (9-3/4) 89 (3-1/2) 1.4 (1/16) 4/78 (3/16) 11-J60-1753 11-H30-1753 B1 197 (7-3/4) 45 (1-49/64) 147.6 (5-13/16) 454 (17-7/8) 248 (9-3/4) 105 (4-9/64) 1.4 (1/16) 4/78 (3/16) 11-H60-1753 11-N60-1753 B2 197 (7-3/4) 45 (1-49/64) 111 (4-3/8) 454 (17-7/8) 248 (9-3/4) 105 (4-9/64) 1.4 (1/16) 4/78 (3/16) 11 41

Dimensions Series 11 11 Enclosure Installation Dimensions Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. A 1 B 1 A 2 B 2 51 [2.01] F C E D Catalog Number 11-C30-1753 11-J30-1753 11-N30-1753 Dimension Reference A1 A2 A1 A2 B B C D E F Min. Min. Min. Min. Min. Max. Min. Min. Min. Max. 171 (6/3-4) 171 (6-3/4) 203 (7-63/64) 203 (7-63/64) 45 (1-49/64) 45 (1-49/64) 76 (3) 76 (3) 178 (7) 178 (7) 454 (17-7/8) 454 (17-7/8) 248 (9-3/4) 248 (9-3/4) 89 (3-1/2) 89 (3-1/2) 1.4 (1/16) 1.4 (1/16) 4.78 (3/16) 4/78 (3/16) 11 11-J60-1753 11-H30-1753 11-H60-1753 11-N60-1753 B1 B2 197 (7-3/4) 197 (7-3/4) 228 (8-63/64) 228 (8-63/64) 45 (1-49/64) 45 (1-49/64) 76 (3) 76 (3) 178 (7) 178 (7) 454 (17-7/8) 454 (17-7/8) 248 (9-3/4) 248 (9-3/4) 105 (4-9/64) 105 (4-9/64) 1.4 (1/16) 1.4 (1/16) 4.78 (3/16) 4.78 (3/16) 42

Dimensions Series 11 Type 3/4/12 - Watertight, Dusttight Sheet Metal Enclosure (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. D Amps Type Dim. Ref. A B C D E F 30 60 Fused & Non-fused Fused & Non-fused A1, A2 B1, B2 305 (12.00) 305 (12.00) 305 (12.00) 305 (12.00) 173 (6.80) 173 (6.80) 224 (8.81) 224 (8.81) 267 (10.5) 267 (10.5) 267 (10.5) 267 (10.5) Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure (30 & 60A) A F E B D C 11 Amps Type Dim. Ref. A B C D E F 30 60 Fused & Non-fused Fused & Non-fused A1, A2 B1, B2 305 (12.00) 305 (12.00) 305 (12.00) 305 (12.00) 173 (6.80) 173 (6.80) 224 (8.81) 224 (8.81) 267 (10.5) 267 (10.5) 267 (10.5) 267 (10.5) 43

Dimensions Series 11 Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. K 5.5 (15/64) A H D C F B J 32 (1-1/4) G (4)- 8 X 13 SOT MTG. HOES (11/32) (17/32) Amps Type Dim. Ref. A B C D F G H J K 30 & 60 Fused & Non-Fused A1 & A2 B1 & B2 226 (8.92) 267 (10.52) 163 (6.42) 214 (8.43) 278 (10.95) 152 (8.0) 216 (8.50) 305 (12.0) Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure (100A) 6 (0.23) O F F ON 11 D Amps Type Dim. Ref. A B C D E F 100 Fused & Non-fused C1 406 (16.00) 406 (16.00) 224 (8.80) 282 (11.10) 368 (14.5) 368 (14.5) 44

Dimensions Series 11 Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure (200 & 400A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. Amps Type Dim. Ref. A B C D E F G H 200 Fused & 406 610 224 282 688 650 368 572 D1 Non-Fused (16) (24) (8-51/64) (11-5/64) (27-5/64) (25-19/32) (14-1/2) (22-1/2) 400 Fused & 610 762 326 384 840 802 572 724 F1 Non-Fused (24) (30) (12-51/64) (15-5/64) (33-5/64) (31-15/32) (22-1/2) (28-1/2) Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (100A) K 5 (3/16) A H D C F B J G (4)- 8 X 13 SOT MTG. HOES 32 (1-9/32) (11/32) (17/32) 11 Amps Type Dim. Ref. A B C D F G H J K Fused & 380 420 215 273 430 305 370 457 5 100 C1 Non-Fused (14-31/32) (16-1/4) (8-31/64) (10-49/64) (16-61/64) (12) (14-9/16) (18) (13/64) 44.1

Dimensions Series 11 Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (200A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. K 11.5 (29/64) A D C F B J G (4)- 10 DIA. MTG. HOES (13/32) Amps Type Dim. Ref. A B C D F G J K 200 Fused & Non-Fused D1 513 (20-13/64) 625 (24-5/8) 292 (11-31/64) 350 (13-25/32) 648 (25-1/2) 457 (18) 686 (27) 11.5 (29/64) Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (400A) K 10.5 (27/64) A D C F B J 11 57mm (2-1/4") G (4)- 10 DIA. MTG. HOES (13/32") Amps Type Dim. Ref. A B C D F G J K 400 Fused & Non-Fused F1 612 (24 1/8) 775 (30 33/64) 343 (13 31/64) 401 (15 23/32) 796 (31 31/32) 555 (21 7/8) 834 (32 27/32) 10.5 (13/32) 44.2