FE1-FE1*ETH Converter User Manual

Similar documents
VersiVision - High Definition Fiber Optic Video

Model INT July 2010

INTECH Micro 2300-RTD6

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

Wide Bank 28 DS3 QUICK START GUIDE

RS485 Card. User Manual

Harris IRT Enterprises Digital Resistance Tester Model XP

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

EIP APPLICABILITY & EFFECTIVITY

Switch Installation. Preparing for Installation. Warnings CHAPTER

Wind display type WSDI-2

Dominion PX. Quick Setup Guide. Before You Begin. Mounting Zero U Models Using L-Bracket. Zero U Size. 1U and 2U Size

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

DTC P1518 Throttle Actuator Control (TAC) Module Serial Data Circuit

REMOTE POWERING Central Energy System ( HUB )

Dispenser Communication Error Codes for units containing the DeLaRue SDD-1700 feeders only

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

AC drive has detected too high a Check loading

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

QUICK REFERENCE MANUAL

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

Flight Systems. Replacement for KASSEC DESCRIPTION

RHINO MOTION CONTROLS

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

ProtoNode FPC-N34 and FPC-N35

PowerScale kva Technical Specifications

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

SmartPak Welding Controller WK-MPS-16 Constant Current

RS485 MODBUS Card. User Manual. Before you start to install this card, please read this User Manual carefully

MSR01. Water heating controller with solar panel support

Introduction To Transmission

Note: If anything is damaged or missing, contact your customer representative immediately.

HFX & HFXE T8 ELECTRONIC BALLAST & COMBINED ELECTRONIC BALLAST AND EMERGENCY INVERTER FOR EX-ENVIRONMENT

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Combined Ventilation Controller RVWS-T-224HA

MODEL 396/398 ELECTRON BEAM SOURCE ROTARY CRUCIBLE INDEXER

Cisco Power Calculator -Power Results

KEYLESS ENTRY SYSTEM & TIRE PRESSURE MONITOR ACCESSORIES & EQUIPMENT General Motors Corp. - Remote Keyless Entry System

X11CA-IM MASTER MODULE

MDE-2381A SERVICE MANUAL. PA0242 Distribution Box GILBARCO INC., 7300 W. FRIENDLY AVENUE, P.O. BOX 22087, GREENSBORO, N.C /90/.

2006trans13_b.doc ACCEPTABLE OPERATING RANGE AND RATIONALITY SENSED PARAMETER FAULT CODE PRIMARY MALF DETECTION PARAMETERS

VAHLE POWERCOM 485. Digital Data Transmission System

ProtoNode RER and ProtoNode LER. Startup Guide

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

IEDA524-H / IEDA520DTB DIGITAL MICROPHONE STATION. Installation Instructions

Quick Setup Guide. WARNING! Connect this product to an AC power source whose voltage is within the range specified on the product's nameplate.

TECHNICAL REFERENCE MANUAL


Features. Description. Table of Contents

RS232. CAN. Integration with Tachograph Continental VDO DTCO

Installing Power Components

Acid Resistant AVC6000

ZT-USB Series User Manual

2006trans13_a.doc MONITORING TIME & DTC TYPE. 600 sec. Type C seconds Type C seconds Type C- Type A. Type A.

PowerScale TECHNICAL SPECIFICATIONS

Part Number AEM 4-CH WIDEBAND UEGO CONTROLLER

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Where There is Miboxer There is Power. User Manual. Model No.: C2-6000

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

For this application note the Ag9400-S will be used as an example of one of our typical PD products.

Low Profile DC Power Supply with Zero Voltage Soft Switching

Series 905-IV16(E) CAN/CANopen Input Modules Installation and Operating Manual

Installing and Removing Power Supplies

2.1 Meter Slip Ring-Bypass Project

Digital/Analog Amplifiers Installation Instructions

Table of Contents. 350 V, 80 kw, 20 kwh, traction battery pack, specifications

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

2003 CVT when used with 2.2L L61 engine in the Saturn ION TRANSMISSION DIAGNOSTIC PARAMETERS

TEL: G&C Electronics CC E. T.

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

SNMP dedicated to ORVALDI Solar Infini

6T30/6T40/6T45 - AUTOMATIC TRANSMISSION

Axiom AMI by StoneL. Installation, Maintenance and Operating instructions. StoneL publication revA

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

EUROPEAN ETS TELECOMMUNICATION November 1992 STANDARD

Expanding Application of FRENIC-Lift Series for Elevators

PowerValue 11/31 T kva

The Fundamentals of DS3

The Fundamentals of DS3

Model ½ Digit Multimeter

Completely free from the Concern of Loss of Position (Alarm Feneration when Step-Out) Perfect Positiooning and Completion (Positioning Completion

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

NetSure. 211 Series DC Power System

Document ID# Buick LeSabre

e-ask electronic Access Security Keyless-entry

Expansion Signal (XSIG) Card Installation Instructions

VFD. Variable Frequency Drive

MATRIX LLC LEVEL CONTROL PANEL

Communicator Installation Sheet. Version 1.0.1

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

Transcription:

FE1-FE1*ETH Converter User Manual

1 General Safety Information Please read the following safety rules to avoid any harm to human body and any damage to other devices when this device is connected to other devices. The product shall be used in specified applicable areas and shall be fixed by technical engineer authorized by us. To prevent fire and to avoid any harm to human body, please Use the appropriate power supply, check power supply type and differentiate anode and cathode carefully; Connect and cut-off properly: when device is powered, do not connect or cut off the data cable; Use proper grounding: before using the product, make sure the proper grounding is made, grounding impendence shall be less than 4ohm; Make the correct connection: ensure to use the default accessories provided along with the device. If you need to make the special connection, please note the PIN definition and make the proper connection; Avoid to touch exposed circuit When the circuit is on, do not touch exposed components if any; Do not operate the device without front panel; Provide good ventilation; Do not operate the device in the humid environment; Do not operate the device in the volatile environment; Keep the surface clean and dry. 2. Fast track FE1-FE1*ETH converter can combine and multiplex an Ethernet and an E1( user side) into an E1 channel and transmit through E1 channel. The bit rate of E1 and Ethernet can be adjusted provided the total bit rate does not exceed the E1 bit rate (1984Kbps). E1-M is uplink channel; E1-S is downlink channel. The PCB for standalone and rack version is same. Please indicate your requirement when order. The following are the operation steps: Connect with appropriate power supply as per back panel power indication; Power on, the device will do self-detection, PWR,E1LOS-M,E1LOS-S indicators shall be on, rest shall be off; Connect Rx of E1-M with Tx of E1 channel on transmission equipment, Tx to Rx ; E1LOS-M alarm indicator shall be off; if there is an error, you can press button to pinpoint the error; Based on client s need, configure the time-slot of E1-S, connect E1 line to TX,RX of E1-S, the E1LOS-S indicator shall be off; Based on Ethernet transmission requirement set up fixed timeslots (through 17~22th dipswitch), connect Ethernet cable, the LINK indicator shall be on, SPD,F/D indicator status shall be as per Ethernet working mode; If you operate as per above steps, the device still does not work, please contact your supplier or our technical staff for assistance. 3. Product Features 2

Provide rich auto-operation and auto-calculation options. Users can configure the device easily; Self-learn Ethernet MAC address, decide forward or filter the data frame based on sourc MAC address and destination MAC address; Ethernet data rate can be configured based on E1-S data rate configuration; Local device can follow the configuration of remote device automatically or users can command remote device to follow local configuration; Provide rich alarming and loop testing function; 4. Technical Specifications E1 Interface Data rate: N*64Kbit/s (N=1-31) Coding: HDB3 Impedance: 75Ω(unbalanced)/120Ω(RJ48-C balanced) Standard: compliant with G.703 G.704 Jitter: compliant with G.832 Connector: Q9/RJ45 Alarm Indicators: code breaking, frame loss, CRC alarm, AIS Ethernet Interface data rate: N*64Kbit/s N=1-31 Transmission speed: 10/100M auto negotiation Duplex mode: full/hall duplex auto negotiation Power supply: Voltage: Stand-alone AC 220V/DC -48V optional Chassis-based: AC220V/DC-48V hot redundancy and swappable; Voltage range: 180 VAC 260 VAC or -38 VDC -72 VDC Power consumption: stand-alone: <5W Chassis-based: <75W Dimension: Stand-alone mini type: 218mm*136mm*44mm, 2 sets can be mounted on 1 19 rack Chassis-based: 483mm*165mm*177mm Operating environment: Working Temp.: -20 +70 Humidity: 95% 5. Front panel 5.1 Indicators There are 9 indicators on the front panel Indicator Name Function Status Device Status 3

Power supply ON Power supply normal PWR indicator OFF No power supply TEST E1LOS-S~E1LOS-M E1SYL-S~E1SYL-M LINK SPD F/D 5.2 Push button One of the testing button is Testing status Blinking pressed at local or remote end indicator OFF Normal ON E1 link code error alarm Blinking AIS alarm E1 link alarm Intermittent blinking Remote device alarm OFF E1 link normal ON E1 frame not synchronized Blinking CRC-4 error checking E1 data flow alarm Intermittent Remote device frame indicator blinking synchronized not OFF E1 data receiving normal Ethernet Link ON Ethernet connected indicator OFF Ethernet not connected Ethernet data rate ON Ethernet data rate: 100Mbps indicator OFF Ethernet data rate: 10Mbps Ethernet Duplex ON Full duplex mode indicator OFF Half duplex There are 4 push buttons on the front panel; ANA: Loop from local E1-M to E1-S/ETH, used to check if local link is ok or not; DIG Loop from local E1-S/Eth to E1-M, used to check remote E1 link and remote device; REM Remote E1-S/ETH loop, the status of REM as follow: PATT Invalid Note: when any one of button is pressed, the normal data communication will be terminated, 4

TEST indicator will be ON. 5.3 Dip Switch There are 3 group of dipswitch on the front panel, the definition of 1~24th position is as follow: S.No Description Configuration 1~5 Starting time slot of 0~31 time slots of E1-M see table 1; E1-M set by E1-S When all set OFF, means starting time slot is 0; 6~8 Invalid reserved The time-slot Detailed configuration see table 2; 9~13 number of E1-M set by E1-S When time-slot number is 0, means E1-S is not used; 14 Invalid reserved 15 Framed mode When this position set to ON, framed mode is enabled enabled Close E1LOS-S When connected with remote E1 multiplexer, remote 16 E1SYL-S blinking E1 device is not E1-S interface, E1LOS-S blinks. Set alarm this position to ON to close this function; Ethernet Time-slot Corresponding Ethernet time-slot number, from 0 to number in E1-M 31,in E1-M, see table 3; When time-slot number is 17~21 0, means Ethernet is not used; When the Ethernet time-slot number is automatically configured, above setup is invalid; Close automatic Ethernet time-slot OFF-automatic configuration ON- Close automatic configuration 22 number When the device is in the automatic configuration configuration mode, based on the 15th dipswitch setup, the time-slot numbers in E1-M is what left by E1-S time slot numbers Command remote device to follow local s configuration --Valid when set as ON; --If this position is valid, all dipswitch except 6th and 23rd dipswitch are invalid for remote device; 23 --if this position of local and remote are both set as ON, wrong configuration will be reported; --If 23rd,24th dipswitch of local device are set as ON, remote alarm message will not be sent to remote device; 24 Command local device to follow remote s configuration --valid when set as ON; --if this position is valid, all dipswitch except 6th and 24th dipswitch are invalid for local device; ----If 23rd,24th dipswitch of local device are set as ON, remote alarm message will not be sent to remote device; 5

Table 1: 1~5 dipswitch starting time-slot configuration **when starting time-slot is 3, E1-S will count time-slot number from 3 rd position; 5 4 3 2 1 Starting time-slot OFF OFF OFF OFF ON 1 OFF OFF OFF ON OFF 2 OFF OFF OFF ON ON 3 OFF OFF ON OFF OFF 4 OFF OFF ON OFF ON 5 OFF OFF ON ON OFF 6 OFF OFF ON ON ON 7 OFF ON OFF OFF OFF 8 OFF ON OFF OFF ON 9 OFF ON OFF ON OFF 10 OFF ON OFF ON ON 11 OFF ON ON OFF OFF 12 OFF ON ON OFF ON 13 OFF ON ON ON OFF 14 OFF ON ON ON ON 15 ON OFF OFF OFF OFF 16 ON OFF OFF OFF ON 17 ON OFF OFF ON OFF 18 ON OFF OFF ON ON 19 ON OFF ON OFF OFF 20 ON OFF ON OFF ON 21 ON OFF ON ON OFF 22 ON OFF ON ON ON 23 ON ON OFF OFF OFF 24 ON ON OFF OFF ON 25 ON ON OFF ON OFF 26 ON ON OFF ON ON 27 ON ON ON OFF OFF 28 ON ON ON OFF ON 29 ON ON ON ON OFF 30 ON ON ON ON ON 31 Table 2: 9~1317~21dipswitch configuration and data rate 13 21 12 20 11 19 10 18 9 17 Data rate Kbit/s OFF OFF OFF OFF ON 64 OFF OFF OFF ON OFF 128 OFF OFF OFF ON ON 192 OFF OFF ON OFF OFF 256 6

OFF OFF ON OFF ON 320 OFF OFF ON ON OFF 384 OFF OFF ON ON ON 448 OFF ON OFF OFF OFF 512 OFF ON OFF OFF ON 576 OFF ON OFF ON OFF 640 OFF ON OFF ON ON 704 OFF ON ON OFF OFF 768 OFF ON ON OFF ON 832 OFF ON ON ON OFF 896 OFF ON ON ON ON 960 ON OFF OFF OFF OFF 1024 ON OFF OFF OFF ON 1088 ON OFF OFF ON OFF 1152 ON OFF OFF ON ON 1216 ON OFF ON OFF OFF 1280 ON OFF ON OFF ON 1344 ON OFF ON ON OFF 1408 ON OFF ON ON ON 1472 ON ON OFF OFF OFF 1536 ON ON OFF OFF ON 1600 ON ON OFF ON OFF 1664 ON ON OFF ON ON 1728 ON ON ON OFF OFF 1792 ON ON ON OFF ON 1856 ON ON ON ON OFF 1920 ON ON ON ON ON 1984 6 Rear panel 6.1 power supply The device supports AC220V/DC-48V, you can choose power supply based on your requirement; When power switch is switched 48V, means you want to use -48VDC power supply; when the power switch is switched to 220VAC, means you want to use 220VAC power supply; When you use -48VDC power supply, you shall connect cathode of DC power supply to cathode of the device, anode of DC power supply to anode of device ; 6.2 E1 connector 75Ω/RX 75Ω unbalanced input 7

75Ω/TX 75Ω unbalanced E1 output; M mark means uplink E1 channel, S mark means downlink user side E1 channel; 6.3 Ethernet Interface (LAN interface) Ethernet interface supports cross-connection and cut-through auto-sensing; Note: when LAN cable is too long, please make sure to connect two PIN of RX into a same UTP, two PIN of TX into a same UTP; 6.4 Bottom panel ON means grounding of E1 link is connected with grounding of system; OFF means grounding of E1 link is disconnected with grounding of system; The first position is RX grounding, the second position is TX grounding; Note : please make sure there shall be at least one side to be grounded. For example: if transmission equipment s TX is grounded, our device is not necessary to be grounded; If transmission equipment is not grounded, our deviced shall be gournded; 7. Rack 7.1 Front panel Front panel There are 17 slots, 15 for NMS card and functional card, 2 for power supply card. NMS Card: If users need network management, the NMS card must be plugged into the first slot; if users do not need network management, this slot can be used for functional card; Function cards: Maximum 15 functional cars can be plugged. Various functional cars can be used. Power supply card: Users can plug the power supply module based on the requirement, the power can be 220VAC, -48VDC. 1+1 redundancy is supported. 7.2 Real panel 8

8. Typical application 1~5th dipswitch should be all OFF 6-8th dipswitch : reserved OFF 14 is invalide, it is resered 15th dipswith is also used to set PCM3 and PCM31 ON-PCM30 OFF-PCM31 16th dipswtich is used close the alarm of sub E1 is sub E1 is not connected to any E1 devices 22: OFF-automatical confirgure Etherent time slot ON-close automatic config 23: command remote device to follow local configuration, it's valid if ON 24: command local device to follow local config normanlly make if OFF, 23,24 CRC check is always enalbed; 9