Specification Approval Sheet

Similar documents
Specification Approval Sheet

Checkup. Make. Signature. Date. Company Stamp: com

Tenergy Corp 1292 Kifer Road Suite 807 Sunnyvale CA 94086

2 1.Nominal Voltage 1.2V. 2 6.End Voltage of Discharge 1.0V

RS Stock number

Specification Approval Sheet

NI-MH LOW-SELF DISCHARGE READY TO USE

Data Sheet. Specifications of Nickel Metal Hydride Battery. Page 1 of 6. Conrad Electronic SE, Klaus-Conrad-Str. 1, D Hirschau. Item no.

Specification. Cylindrical Li-ion battery. Type: Product model battery VER A Product Specification 3.6V 1400mAh Date 2005/1/3

Datasheet / Product specification Model: Solar AAA

NI-MH BATTERIES SPECIFICATIONS

L CR MAH

Specification Approval Sheet

Specification Approval Sheet

MODEL NO:NI-MH 4 AA V

Specification Approval Sheet

ENGLISH. RS Stock number Description:

APPROVE SHEET. Customer : Lithium ion polymer rechargeable battery. Cell s model name : Assembly: Date : 2008/01/29.

Product Specification

This specification is applicable to the Nickel -Metal Hydride rechargeable batteries for type H320BC Model : H320BC

Specifications. Model: LiNiCoMn 3.7V 2000mAh. Prepared Checked Approved. AA Portable Power Corp Address:

EEMB CO., LTD. Specification

RS Stock No

SPECIFICATION OF PRODUCT

EEMB CO., LTD. Specification

ENGLISH. RS Stock No

Polymer Lithium Ion Battery. Specifications. Model: PL D. Approval Checked Draft

Specification Approval Sheet

Specification Approval Sheet

PRODUCT SPECIFICATION. Rechargeable Nickel Metal Hydride Battery Model: GPTC206

EEMB CO., LTD. Specification

Sanyo Nickel-Metal Hydride Rechargeable Batteries

EEMB CO., LTD. Specification

Specification. High temperature NiCd Rechargeable AA Cell: 1.2V 900 mah

Specification Approval Sheet

Specification Approval Sheet

Soshine International. Li-ion Battery. Specification. Model: 18650USB Prepared Auditing Approved WUSUN L.XUN SILING

EEMB CO., LTD. Specification

S P E C I F I C A T I O N S

PRODUCT DATASHEET. is brought to you by. SOS electronic distribution of electronic components

Specification Approval Sheet

Specifications Model:

Lithium Ion Battery Specifications

Li-ion Battery Specification

PRODUCT SPECIFICATION

High Temperature Rechargeable Nickel-Metal Hydride Cylindrical Battery Pack, 3 cell, 4000mAh

Specification Approval Sheet

CHARACTERISTICS FOR. NEXcell NICKEL-METAL HYDRIDE RECHARGEABLE BATTERY PACKS. MODEL HTD x 10

Specification Approval Sheet

Lithium Polymer Rechargeable Battery Pack Tested and approved to UN38.3

Lithium Polymer Battery DATA SHEET

SHENZHEN PKCELL BATTERY CO., LTD. Polymer Li-ion Battery Technology Specification

Alkaline Manganese Dry Battery AM4/LR03

1. Product Specification

Specification Approval Sheet

Alkaline Manganese Dry Battery AM9VF

Technical Specification

Specification Approval Sheet

No Q/LX.S.E Edition A/0. Expocell Group, Inc. Cylindrical Li/MnO 2 Battery. Specification. Battery Type: CR123A(CR17345) Customer.

Specification Approval Sheet

Li-Polymer Battery Technology Specification

Ni-Cd Battery Product Specification

Specification Approval Sheet

Lithium-ion Battery DATA SHEET

Specification Approval Sheet

Document Number: G006 Revision:09 Page 1 of 5

Specification Approval Sheet

Specification Approval Sheet

Specification Approval Sheet

TYPE:UP-SC3600mAh (Flat) Specifications. Dimensions. Typical characteristics Standard charge characteristics. Nominal voltage 1.2V.

Specification Approval Sheet

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

Specification Approval Sheet

Sanyo Nickel-Metal Hydride Rechargeable Batteries

Zinc Chloride Dry Battery SUM3/SUPER/G

Product Specifications

Contents. Page 1. Publication Record Safety Instructions Extent of the Application Battery Classification and Type 6

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

Lithium-ion Battery DATA SHEET

Specification Approval Sheet

Spec. No. INR E Version No. 1.0

TECHNOLOGY FILE GB CELL. FILE NAME:Specification for 18650C4 Cylindrical. Lithium Ion Rechargeable Battery PREPARED BY REVIEWED BY APPROVED BY

The document describes the product specification of the LiFePO4 polymer lithium-ion rechargeable battery cell supplied by Tenergy Corporation.

Specification Approval Sheet

EEMB CO., LTD. Lithium Manganese Dioxide Battery Specification. High Power Type. Prepared Checked Approved. Signature Checked Approved

Specification Approval Sheet

Lithium-ion Battery DATA SHEET

PRODUCT SPECIFICATION. Rechargeable Nickel Metal Hydride Battery Model: GP210AAHC(CS)

Sealed Rechargeable Nickel Cadmium N800AA/BTNP

Specification. For. LiFePO 4 Rechargeable Cell. EnnoPro Group Limited. Cell Type : CEBA AH

Specification Approval Sheet. signed by client. signed by manufacturer

Model No:357 Page 1 of 7. Silver Oxide Button Cell 357. The specification is applicable to the Silver Oxide Button Cell 357 supplied

Zinc Chloride Dry Battery SUM5/EXTRA/G

Silver Oxide Button Cell 303F

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

Specification Approval Sheet

Alkaline Manganese Button Cell L828F

Li-ion Rechargeable Button Cell. Specification

Silver Oxide Button Cell 397. The specification is applicable to the Silver Oxide Button Cell 397 supplied by CHUNG PAK BATTERY WORKS LTD. -0.

Lithium Ion Rechargeable Cell

Transcription:

Specification Approval Sheet Name: Nickel Metal Hydride Battery Model: 10302 SPEC: AA 1.2V 1800mAh 10C Approved By Checkup Make Signature Date Customer Confirmation Company Name: Stamp: 436 Kato Terrace, U.S.A. www.tenergybattery.com

1. BATTERY MODEL 10302 2. NOMINAL SPECIFICATION 2-1.Nominal voltage 1.2V 2-2.Nominal capacity* 2-3.Minimum capacity* 1800mAh 1600mAh 2-4.Charging** Standard charging Quick charging Rapid charging 160mA for 16 hours 800mA for 2.4hours, ΔV=5mV 1600mA for 1.2hours, ΔV=5mV 2-5.End voltage of discharge 1.0V 2-6.Temperature (recommended) Standard charge Quick charge Rapid charge Discharge: Storage: Less than 30 days Less than 90 days Less than 1 year 0~40 o C 10~40 o C 10~30 o C -10~50 o C -20~50 o C -20~40 o C -20~30 o C 2-7.Relative humidity 45~85% 2-8.Weight Approx. 26g 2-9.Dimensions shown in the page 9 Note: *: Discharge capacity when the battery unit is discharged at 320mA after being standard charged. Five cycles are permitted for this test.the test shall be terminated at the end of the first cycle which meets the requirement. **: Unless otherwise stated in these specifications, the battery unit should be discharged to 1.0V end voltage with 320mA before charging. 2010. All rights reserved. Page 2 of 9

3. APPEARANCE There shall be no practical damage such as conspicuous liquid electrolyte leakage, flow and dirt under conditions of storage or operation as specified herein. 4. ELECTRICAL CHARACTERISTICS 4-1.Testing conditions The battery shall be evaluated within 1 month from the arrival date. Unless otherwise stated in these specifications, the following test shall be carried out in an ambient temperature of 20±5 o C, relative humidity of 65±20%. 4-2.Terminal voltage (O.C.V) Open circuit voltage shall be a minimum voltage of 1.25V within 14 days after being standard charged. 4-3. Internal resistance (IEC61951-2(2003)7.10.1) Within 1 hour after being standard charged, the internal resistance is not greater than 20mΩ, as tested by 1000Hz AC source. 4-4.Capacity(IEC61951-2 (2003)7.2.1) 4-4-1.The battery unit shall be capable of supplying 320mA (0.2C) continuous discharge current for a minimum of 300 minutes to the 1.0V end voltage within 1 hour after being standard charged. 4-4-2.The battery unit shall be capable of supplying 800mA (0.5C) continuous discharge current for a minimum of 110 minutes to the 1.0V end voltage within 1 hour after being standard charged. 4-4-3.The battery unit shall be capable of supplying 1600mA (1.0C) continuous discharge current for a minimum of 54 minutes to the 0.9V end voltage within 1 hour after being standard charged. 4-5.High rate discharge performance 4-5-1.The battery unit shall be capable of supplying 4.8A (3C) continuous discharge current for a minimum of 17 minutes to the 0.9V end voltage within 1 hour after being standard charged. 4-5-2.The battery unit shall be capable of supplying 8A (5C) continuous discharge current for a minimum of 10 minutes to the 0.8V end voltage within 1 hour after being standard charged. 4-5-3.The battery unit shall be capable of supplying 16A (10C) continuous discharge current for a minimum of 4.8 minutes to the 0.8V end voltage within 1 hour after being standard charged. 4-6.Temperature characteristics 2010. All rights reserved. Page 3 of 9

4-6-1.Within 1 hour after being standard charged at 40 o C, the battery unit shall be discharged at 20 o C, at a current of 320mA to 1.0V end voltage, discharge time shall be a minimum of 210 minutes. 4-6-2. Within 1 hour after being standard charged at 20 o C, the battery unit shall be discharged at 0 o C, at a current of 320mA to 1.0V end voltage, discharge time shall be a minimum of 210 minutes. 4-7.Charge (capacity) retention (IEC61951-2(2003)7.3) After being standard charged battery unit is stored for 28 days at 20±2 o C, the battery unit shall be discharged at 20 o C, at a current of 320mA to 1.0V end voltage; discharge time shall be a minimum of 180 minutes. 4-8.Overcharge (IEC61951-2(2003)7.6.1) Within 1 hour after being charged at a current of 160mA for 48 hours, the battery unit shall be discharged at 20 o C, at a current of 320mA to 1.0V end voltage, discharge time shall be a minimum of 300 minutes. 4-9.Endurance in cycles (IEC61951-2(2003)7.4.1.1) Prior to the endurance in cycles test, the battery unit shall be discharged at 320mA to 1.0V end voltage. A battery unit shall be capable of 500 minimum cycles under the conditions as follows. 4-10.Safety Cycle Charge Rest Discharge 1 160mA for 16hours None 400mA 140minutes 2~48 400mA for 190minutes None 400mA 140minutes 49 400mA for 190minutes None 400mA to 1.0V 50 160mA for 16hours 1h to 4h 320mA to 1.0V Cycles 1 to 50 shall be repeated until the discharge time on any 50 th cycle becomes less than 3 hours. At this stage, repeat 50 th cycle, if the discharge time is less than 3 hours again the test is terminated. Note: If battery unit voltage drops below 1.0V, discharge shall be discontinued. 4-10-1.Continuous low-rate charging (IEC62133(2002)4.2.1) After standard charged battery unit is charged at 45mA~80mA for 28 days, no fire or no explosion. 2010. All rights reserved. Page 4 of 9

4-10-2.Forced discharge (IEC62133(2002)4.3.10) The discharged battery unit is subjected to a reverse charge at 1600mA for 90 minutes, no fire or no explosion. 4-11.Vibration (IEC62133(2002)4.2.2) The battery unit shall be no fire, no leakage or no explosion, when it is tested under the following conditions after being standard charged. Frequency Amplitude Rate of frequency variety Duration 10~55Hz 0.76mm 1 Hz/minute 90 minutes /axis (axis: X Y Z) 270 minutes in all 5. ENVIRONMENTAL PROTECTION REQUIREMENT 5-1.The requirement on Hazardous Substances in the materials should comply with TENERGY S criterion on HSF. 5-2. The requirement on Hazardous Substances in the Products should comply with 2006/66/EC and TENERGY S criterion on HSF. 6. TRANSPORT 6-1.To ensure battery safety during delivery, SOC (state of charge) must be below 35%, inside temperature of container could not be over 35. Product holder should be responsible for any possible loss during delivery if above conditions cannot be met completely. 6-2.Inside temperature of container must be below 20 if any client requires SOC (state of charge) above 35%, the distance between battery master cartons should be not less than 10cm in container, and coercive air cross ventilation system is required in container to ensure even temperature for each master carton. Product holder should be responsible for any possibly accidental loss if above conditions cannot be met completely. 7. PRECAUTION Please keep in mind the following points when designing and manufacturing equipment. Please insert in your instruction manual. To prevent equipment malfunctions from affecting the batteries, be sure to use protection devices for electrical circuits and batteries.!danger! Failure to carefully observe the following procedures and precautions can result in leakage of battery fluid (electrolyte), heat generation, explosion, fire and serious personal injury! 2010. All rights reserved. Page 5 of 9

Never dispose of TENERGY batteries in a fire or heat them. Do not connect the (+) positive and (-) negative terminals of TENERGY batteries together with electrically conductive materials, including lead wires. Do not transport or store TENERGY batteries with their uncovered terminals or connected with a metal necklace or other electrically conductive material. When carrying or storing batteries, use a special case. Only charge TENERGY batteries using those specific chargers that satisfy TENERGY S specifications. Only charge batteries under the conditions specified by TENERGY. Never disassemble TENERGY batteries. Doing so may cause an internal or external short circuit or result in exposed material of battery reacting chemically with the air. It may also cause heat generation, explosion and fire. Also, this is dangerous as it may cause splashing of alkaline fluid. Never solder lead wires directly on to TENERGY batteries. The (+) positive and (-) negative terminals of TENERGY batteries are predetermined. Do not force the terminals to connect to a charger or equipment. If the terminals cannot be easily connected to the charger or the equipment, check if the (+) and (-) terminals are incorrectly positioned. The gas release vent which release internal gas is located in the (+) positive terminal of the TENERGY battery. For this reason, never deform this section or cover or obstruct its gas release structure. Do not directly connect TENERGY batteries to a direct power source or the cigarette lighter socket in a car. Do not use TENERGY batteries in any equipment other than those specified by TENERGY. TENERGY batteries contain a strong colorless alkaline solution (electrolyte). The alkaline solution is extremely corrosive and will cause skin damage. If any fluid from a TENERGY battery comes in contact with user s eyes, they should immediately flush their eyes and wash them thoroughly with clean water from the tap or another source and consult a doctor urgently. The strong alkaline solution can damage eyes and lead to permanent loss of eyesight. When TENERGY batteries are to be incorporated in equipment or housed within a case, avoid air-tight structures, as this may lead to the equipment or the case being damaged or may be harmful to users.!warning! Do not apply water, seawater or other oxidizing reagents to TENERGY batteries, as this can cause rust and heat generation. If a battery becomes rusted, the gas release vent may no longer operate, and can result in explosion. 2010. All rights reserved. Page 6 of 9

Do not over-charge TENERGY batteries by exceeding the predetermined charging period specified by the battery charger s instructions or indicator. If TENERGY batteries are not fully charged after the battery charger s predetermined charging period has clasped, stop the charging process. Prolonged charging may cause leakage of battery fluid, heat generation, and explosion. Be sure to handle recharged batteries carefully as they may be not. TENERGY batteries contain a strong colorless alkaline solution (electrolyte).if the skin or clothing comes in contact with fluid from a TENERGY battery; thoroughly wash the area immediately with clean water from the tap or another source. Battery fluid can irritate the skin. Do not connect more than 21 TENERGY batteries in series, as this may cause electrical shocks, leakage of battery fluid and heat generation. Do not remove the outer tube from a battery or damage it. Doing so will expose the battery to the risk of a short circuit, and may cause leakage of battery fluid, heat generation, explosion and fire. If TENERGY batteries leak fluid, change color, change shape, or change in any other way, do not use them, otherwise they may cause heat generation, explosion and fire. Keep TENERGY batteries and the equipment using them out of the reach of babies and small children, in order to avoid accidental swallowing of the batteries. In the event the batteries are swallowed, consult a doctor immediately. When the operating time of a TENERGY battery becomes much shorter than its initial operating time even after recharged, it should be replaced to a new battery as its battery life has ended.!caution! Do not strike or drop TENERGY batteries. Store TENERGY batteries out of the reach of babies and small children. When charging or using a battery, do not let babies or small children remove the battery from the charger or the equipment being used. Be sure to charge TENERGY batteries within a temperature range of 0 to 40 deg C (degrees Celsius). Be sure to use the recommended charging method for TENERGY batteries read the battery charger s instruction manual carefully. Do not use or store battery at high temperature, such as in strong direct sunlight, in cars during hot weather, or directly in front of a heater. This may cause leakage of battery fluid. It could also impair performance and shorten operating life of TENERGY batteries. 2010. All rights reserved. Page 7 of 9

Be sure to turn off the equipment after use of TENERGY batteries, otherwise may result in leakage of battery fluid. After removed from equipment, store TENERGY batteries in a dry place and within the recommended storage temperature range. This will help preserve the batteries performance and durability and minimize the possibility of leakage of battery fluid or corrosion. (TENERGY recommends the storage temperature range from -20 to +30deg. (for longer service life). Storage batteries should be charged one time every four months under the storage temperature of 30 o C and below, every three months under 40 o C and below, and every one month under 50 o C and below. After long term storage, there is a possibility that the battery could not be fully charged. In order to fully charge it, please charge and discharge battery for a few times. Do not use old and new batteries mixed together, or batteries at different charge levels. Do not use the TENERGY battery mixed with a dry cell or other batteries of different capacity, type, or brand name. This may cause leakage of battery fluid and heat generation. If the TENERGY battery terminals become dirty, clean up them with a soft dry cloth prior to use. Dirt on the terminals can result in poor contact with the equipment, loss of power, or inability to charge. 8. WARRANTY TENERGY will be responsible for replacing the batter against any defects or poor workmanship for six months from the date of shipping. Any other problems caused by malfunction of the equipment or misuse of the battery are not under this warranty. Notice: To assure safety, please consult to the TENERGY technical staff for your applications including electrical specifications, mechanical designs, protective devices and any special specification. TENERGY reserve the right to alter or amend the design, model and specification without prior notice. 2010. All rights reserved. Page 8 of 9

Data Sheet Nominal voltage (V) 1.2 Capacity* Nominal 1800 (mah) Minimum 1600 Standard 160mA 16hours Charging** Quick 800mA 2.4hours - V=5mV Rapid 1600mA 1.2hours - V=5mV Standard 0~40 charge Temperature Quick charge 10~40 recommended ( o Rapid charge 10~30 C) Discharge -10~50 Storage -20~30 Internal resistance 20mΩ End voltage of discharge 1.0V Charge (capacity) retention 60% Weight Approx. 26g Dimensions D Diameter 14.5 +0-0.7 With tube H Height 49.5 +0-1.5 (mm) a Top diameter 6.5-7.1 Drawing Voltage/V Voltage/V Discharge capacity /% Battery Model:TENERGY-50AAP1600 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 120 100 80 60 40 20 Charging Curves at Various Rates(20±5 ) 1.0C 0.5C 0.1C 0 20 40 60 80 100 120 140 160 180 Charge Capacity/% High Rates Discharge Curves(20±5 ) 10C 0 2 4 6 8 10 12 14 16 18 20 Time/minutes Note: *: Discharge capacity when the battery unit is discharged at 320mA to the 1.0V end voltage after being charged at 160mA for 16 hours. **: Please discharge to the 1.0V end voltage with 320mA before charging the battery unit. 5C IEC Cycle Life Curve (20±5 ) 0 50 100 150 200 250 300 350 400 450 500 550 Number of Cycles 3C The data sheet is for reference only and should not be used as a basis for product described guarantee or warranty. 2010. All rights reserved. Page 9 of 9