ACCESSIBILITY REVIEW

Similar documents
ACCESSIBILITY REVIEW

Accessible Routes. Chapter 1. Accessible Routes & Clearances. General Notes

NAU DESIGN GUIDELINES FOR DISABLED ACCESS PARKING AND ACCESSIBLE ROUTE AT VEHICULAR TRAFFIC AREAS

The Moscone Center Facility Accessibility Information

ADA Checklist RESTAURANTS AND CAFETERIAS

Public Health Services San Joaquin Co.

FORM A: ACCESSIBILITY CHECKLIST. Questions. Possible Solutions A. PARKING. Location Name Location Address: (street address) (city) (state) (zip)

Chapter 5. General Site and Building Elements

ACCESSIBILITY DETAILS FOR PARKING

CHAPTER 4: ACCESSIBLE ROUTES

ADA Became Law In 1990

Surveyor Information

Shelter: Primary Shelter Secondary Shelter Respite Site Only Client Service Center Pet Shelter

th Edition Florida Accessibility Code for Building Construction

ACCESSIBILITY SELF-EVALUATION CHECKLIST

Chapter 8 - Special Rooms and Spaces

GOVERNOR S OFFICE of PLANNING AND RESEARCH

Purpose: General Provisions:

ADA Entrance Accessibility

Temporary Sales Trailer Application

ZONING CODE PARKING REGULATIONS

REAR +/- 94' 20' 10' 10'-4" 9'-6" 10'-3" 10' 20' 13'-2" Private Office 25. Private Office 23 Private Office 24 7'-1" Open Space 3 14'-7"

CITY OF LEMOORE AMERICAN WITH DISABILITIES ACT TRANSITION PLAN FINAL

APPENDIX B TRAINING MANUAL

ACCESSIBILITY. for Public Charging Stations. Plug-In Electric Vehicle Planning Toolbox

(2) For mounting heights suitable in schools and other facilities used primarily by children see section

ARTICLE 8 OFF-STREET PARKING AND PRIVATE DRIVEWAY STANDARDS

Designing Pedestrian Facilities for Accessibility. Module 7 Street Furniture and On-Street Parking

Georgia-Pacific Compliance Guide for Title III of the Americans with Disabilities Act

CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES

Location: Fraser Fort George, Prince George, Northern BC - Municipal : Trail (Great Northern Circle Route)

Accessibility Survey Techniques. John Salmen, AIA Andrew Yarrish, AIA Universal Designers & Consultants, Inc.

APPLICATION OF SECTION 3.8 OF THE 2012 ONTARIO BUILDING CODE FOR: BARRIER-FREE AUDIT OF SENECA COLLEGE MARKHAM CAMPUS MARKHAM, ONTARIO

ACCESSIBILITY GUIDE REVISED

ACCESSIBLE COMMUNITY BUILDER CHECKLIST

Access California. New Regulations for Electric Vehicle Charging Stations. presented to The City of Palo Alto, California

County of Fresno. South Annex Jail ADA Transition Plan LARS ANDERSEN & ASSOCIATES, INC. Prepared by:

CHAPTER 90. STREETS, SIDEWALKS AND PUBLIC WAYS ARTICLE II. USE OF STREETS, SIDEWALKS AND PUBLIC WAYS DIVISION 10. SIDEWALK CAFÉS

Article 6: Off Street Parking and Loading Standards. Table of Contents. page

DIVISION 6: PLUMBING ELEMENTS AND FACILITIES

Parking and Loading. Page 1 of 7

ANN ARBOR CITY NOTICE ORDINANCE NO. ORD OFF STREET PARKING CHAPTER 59

Oregon Conventi Center

Amusement Rides. ADA Checklist for Existing Facilities. Amusement rides should be accessible to everyone, including people with disabilities.

Chapter 6. Plumbing Elements and Facilities

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

6.16 OFF-STREET PARKING AND LOADING REQUIREMENTS

Also below is a limited list of the proposals which will be included in the first draft of the revised ICC/ANSI A117.1 standard for accessibility.

Table Station Elements

Capital Programs Institute Provider Number: I Accessibility Training Course Number: CLA-AT-0917

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 5 GROUP B AND GROUP M OCCUPANCIES

THE CORPORATION OF THE TOWNSHIP OF MIDDLESEX CENTRE BY-LAW NUMBER

Plan Check Policies and Guidelines

CHAPTER 2 ZONING AND DEVELOPMENT

Electric Vehicle Charging System Guidelines for Residential Buildings

ORDINANCE NO

800 Access Control, R/W Use Permits and Drive Design

Parking Space and Drive Aisle Dimension Requirements June 2011

Appendix D: ADA Self- Assessment

MOTOR VEHICLE ORIENTED BUSINESSES.

EVCS Access California

Please direct all questions regarding this policy and its administration to:

OFF-STREET PARKING. A. Parking facilities for each use shall be provided in accord with the minimum requirements set forth in Table 9-1.

TRAFFIC CONTROL REGULATIONS

St. Catharines Transit Commission Accessibility Plan. St. Catharines Transit Commission Accessibility Plan

Operations Center FAQs

Barrier Free Design Guide

DISCUSSION For the purpose of this General Order, the following definitions shall apply:

Expedited Permitting Process for Electric Vehicle Charging Stations

Plan Check Policies and Guidelines

Chapter ACCESS, PARKING AND TRAFFIC*

TRAFFIC MANAGEMENT STANDARDS CITY OF GARLAND TRANSPORTATION DEPARTMENT

150 OFF-STREET PARKING AND LOADING REGULATIONS

(New), (New)

Design of Parking Facilities. Design of Parking Facilities. Location of Parking Facilities

BILLERICA OPEN SPACE AND RECREATION PLAN

Parking Regulations. Responsibility

PACIFIC FAIR ACCESS STATEMENT. Using this document. Facility Summary. Facility details

INFORMATION BULLETIN / PUBLIC - ZONING CODE REFERENCE NO.: L.A.M.C A5 Effective: DOCUMENT NO.: P/ZC Revised:

Terminal Alternatives

I-290 Phase I Study Summary of NFPA-130 Analysis of Proposed CTA Station Platform Widths May 2016

Fire Apparatus Access Roads in Marysville

ORDINANCE NUMBER 3424

Chapter 17 TRAFFIC AND VEHICLES. Adoption of Uniform Rules of the Road. Temporary Traffic Regulations.

STANDARD DRAWING INDEX

Title 33, Planning and Zoning Chapter /1/11 Parking And Loading

Enhanced Accessibility in the ICC/A Pacific ADA Update Conference Presented by: Kermit Robinson, CBO International Code Council

DRAFT Commission, based upon the requirements of comparable uses listed.

CHAPTER 69 PARKING REGULATIONS

Traffic Management Plan and Queuing Analysis Lakehill Preparatory School Z Hillside Drive, Dallas, TX October 27, 2015

Moraga-Orinda Fire District

IMPROVEMENT CONCEPTS

The following provisions shall apply to the Broughton Street district:

LINDON CITY CODE. Chapter OFF-STREET PARKING

TRAFFIC PARKING ANALYSIS

ELMORE COUNTY HIGHWAY DEPARTMENT

Ontario Regulation. Accessibility for Ontarians with Disabilities Act, (Integrated Accessibility Standards)

CHAPTER 72: PARKING RULES. Stopping, Standing or Parking

Standards for Barrier-Free Campus Office for Students with Disabilities University Planning Office June 2004

8A General Information A. General 1 B. References... 1

Transcription:

Swinerton Builders CA Lic. N o 92 15 Business Park Way, Suite 101 Sacramento, CA 95828 Tel: 916.383.4825 Fax: 916.383.6014 www.swinerton.com INTEGRITY LEADERSHIP PASSION EXCELLENCE ACCESSIBILITY REVIEW FOR Kimber Management, LLC 30 Liberty Ship Way Sausalito, CA 94965 Certified Access Specialist Survey By: Amy Casado, CASp 294

INTRODUCTION OVERVIEW: An on-site accessibility review of 30 Liberty Ship Way, Sausalito, CA, an existing Class B office building, was conducted during July and August of 2013. This review included facility and site accessibility including accessible routes of travel, parking, dos, and toilet facilities. Employee wk areas and alarm systems are excluded from this survey. A summary of findings and recommendations are contained herein. This survey has been conducted under the current code regulations listed below: 2010 ADA Standards f Accessible Design Title III 28 CFR Part 36 - Public Accommodations and Commercial Facilities** 2010 Califnia Building Code Title 24, Part 2, Chapter 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Publicly Funded Housing Califnia Building Code, Title 24, Part 2 Emergency Regulations effective July 1, 2012. **Element-by-Element Safe Harb The Standards include a general safe harb under which elements in covered facilities that were built altered in compliance with the 1991 Standards would not be required to be brought into compliance with the 2010 Standards until the elements were subject to a planned alteration. A similar safe harb applies to elements associated with the path of travel to an altered area. Refer to CFR Part 36.304, (d), (1), (i) Safe Harb f additional infmation. Findings and recommendations within this rept are based on interpretations and do not imply legal authity. As such, this rept is being provided without representations of warranties f err and/ omissions, either expressed implied. GENERAL INFORMATION: In public accommodations and commercial facilities, any renovation new construction that occurs after January 26, 1992, are subject to meet full code specifications of the Americans with Disabilities Act (ADA) Title III, 28 Code of Federal Regulations (CFR) Part 36; and Title 24, Part 2, of the Califnia Building Code (CBC); and are to be in full compliance with the most restrictive provisions of either the ADA the CBC. Although the CBC only requires improvements to access when an alteration to a facility takes place, public accommodations have an ongoing obligation to remove readily achievable barriers under the provisions of the ADA. Readily achievable barriers are defined as easily accomplished and able to be carried out without much difficulty expense. Determining if barrier removal is readily achievable is determined on a case by case judgment. Facts to consider are the nature and cost of the barrier and the financial resources of the entity and the parent company. Under the ADA, an entity must remove barriers as they are become readily achievable and is an on-going obligation until the building reaches full compliance. It is recommend that all barriers that are identified in this evaluation, and that are readily achievable, be removed as soon as possible with other barriers being removed as they become readily achievable. A transition plan should be developed to assist in planning the remediation of all barriers that are not currently readily achievable to remove. Periodic maintenance to ensure continued accessibility is essential in providing a safe and usable environment. Parking lot markings, signage, do opening Introduction - i

pressures, and maintaining clear flo space at dos and other elements and fixtures must be part of an ongoing maintenance schedule. Priities f barrier removal include the following: 1. An accessible entrance and path of travel 2. Access to goods and services 3. An accessible restroom f each sex 4. Accessible items such as drinking fountains, telephones, etc. 5. When possible, additional accessible elements such as parking, stage, and alarms Public accommodations ADA obligations f barrier removal can be found in Title 24, Part 2, Section 1134B of the Califnia Building Code; and the Department of Justice s ADA Title III regulations at 28 CFR part 36.304. RESOURCES: Califnia Department of General Services Division of the State Architect, Access Compliance www.dgs.ca.gov/dsa/programs/progaccess.aspx U.S. Department of Justice ADA Infmation www.ada.gov 2010 ADA Standards f Accessible Design www.ada.gov/2010adastandards_index.htm 1991 ADA Standards f Accessible Design www.ada.gov/reg3a.html#anch-appendix-52467 ADA Update: A Primer f Small Business www.ada.gov/regs2010/smallbusiness/smallbusprimer2010.htm Tax Deductions and Credits f Barrier Removal www.ada.gov/taxincent.htm Introduction - ii

Kimber Management, LLC 30 Liberty Ship Way Sausalito, Ca 94965 NOTICE TO PRIVATE PROPERTY OWNER/TENANT: YOU ARE ADVISED TO KEEP IN YOUR RECORDS ANY WRITTEN INSPECTION REPORT AND ANY OTHER DOCUMENTATION CONCERNING YOUR PROPERTY SITE THAT IS GIVEN TO YOU BY A CERTIFIED ACCESS SPECIALIST. IF YOU BECOME A DEFENDANT IN A LAWSUIT THAT INCLUDES A CLAIM CONCERNING A SITE INSPECTED BY A CERTIFIED ACCESS SPECIALIST, YOU MAY BE ENTITLED TO A STAY (TEMPORARY STOPPAGE) OF THE CLAIM AND AN EARLY EVALUATION CONFERENCE. IN ORDER TO REQUEST THE STAY AND EARLY EVALUATION CONFERENCE, YOU WILL NEED TO VERIFY THAT A CERTIFIED ACCESS SPECIALIST HAS INSPECTED THE SITE THAT IS THE SUBJECT OF THE CLAIM. YOU WILL ALSO BE REQUIRED TO PROVIDE THE COURT AND THE PLAINTIFF WITH THE COPY OF A WRITTEN INSPECTION REPORT BY THE CERTIFIED ACCESS SPECIALIST, AS SET FORTH IN CIVIL CODE SECTION 55.54. THE APPLICATION FORM AND INFORMATION ON HOW TO REQUEST A STAYAND EARLY EVALUATION CONFERENCE MAY BE OBTAINED AT http://www.courtinfo.ca.gov/selfhelp/. YOU ARE ENTITLED TO REQUEST, FROM A CERTIFIED ACCESS SPECIALIST WHO HAS CONDUCTED AN INSPECTION OF YOUR PROPERTY, A WRITTEN INSPECTION REPORT AND OTHER DOCUMENTATION AS SET FORTH IN CIVIL CODE SECTION 55.53. YOU ARE ALSO ENTITLED TO REQUEST THE ISSUANCE OF A DISABILITY ACCESS INSPECTION CERTIFICATE, WHICH YOU MAY POST ON YOUR PROPERTY. This rept has been issued in compliance with Califnia Civil Code Section 55.53 and does NOT comply with all applicable construction related accessibility standards. A CASp Determination Pending classification has been determined as defined in Califnia Civil Code Section 55.52 (a) 5. A reasonable time frame f completing items noted in this rept and a determination of what barriers are Readily Achievable will be the responsibility of the property owner. Prepared by: Amy Casado 9/25/2013 Amy Casado, CASp #294 Date

TABLE OF CONTENTS TABLE OF CONTENTS General Facility and Survey Infmation Summary Sheets SECTION 1 Sheet A: Parking (PK) SECTION 2 Sheet B: Passenger Loading Zones (PZ) NOT APPLICABLE SECTION 3 Sheet C: Exteri Routes Of Travel (ER) SECTION 4 Sheet D: Entrances (EN) SECTION 5 Sheet E: Interi Routes of Travel (IP) SECTION 6 Sheet F: Rooms and s (RS) SECTION 7 Sheet G: Toilet Rooms (TR) SECTION 8 Sheet H: Assembly Use Areas (AA) NOT APPLICABLE SECTION 9 Sheet I: Alarms (AL) NOT APPLICABLE SECTION 10 Sheet J: Exhibits Survey Fms Fm 1: Parking Fm 2: Passenger Loading Zones NOT APPLICABLE Fm 3A: Exteri Routes of Travel, Public Rights-of-Way Fm 3B: Exteri Routes of Travel, On-Site Fm 4: Curb Ramps Fm 5: Drinking Fountains Fm 6: Telephones NOT APPLICABLE Fm 7: Ramps NOT APPLICABLE Fm 8: Stairs Fm 9: Platfm Lifts NOT APPLICABLE Fm 10: Building Entrances and Exits Fm 11: Dos and Gates Fm 12: Building Lobbies and Crids (Interi Accessible Route) Fm 13: Elevats Fm 14: Rooms and s Fm 15A: Large Assembly Areas NOT APPLICABLE Fm 15B: Small Assembly Areas NOT APPLICABLE Fm 16: Toilet Rooms Fm 17: Shower Facility Fm 18: Reserved Fm 19: Signage Fm 20: Alarms NOT SURVEYED Fm 21: Reserved Fm 22: Reserved Fm 23: Hazards

GENERAL FACILITY AND SURVEY INFORMATION Data Sheet Facility Name: Date: 30 Liberty Ship Way, Sausalito, CA 94965 September 25, 2013 a. Facility Name b. Facility Address (, Street) c. Facility Address (City, Zip) d. Contact Info e. Phone Fax f. Number of On-site Parking Stalls g. Square Footage h. of Sties and Size of Each i. Date of Construction (First Certificate of Occupancy) j. Date(s) and Type(s) of Previous Alteration(s) k. Circle Mark Type of Survey 30 Liberty Ship Way Sausalito, CA 94965 Bruce Huff 415-331-6466 415-331-5524 bruce.huff@kimber.net 111 40,000 3 Sties 1943 2007 New Construction Renovation Lease Other (specify): GENERAL SURVEY l. Tenant Contact Info (Lease ) m. Suite (s) and Size of Each (SF) n. Name of Survey and Date of Survey o. Survey Contact Info p. Phone Fax Name: Amy Casado, CASp 294 P.O. Box 1929, Rocklin, CA 95677 Date: July/August 2013 916-690-4935 916-740-2834 acasado@pacfmance.com Additional Comments: See: EXHIBIT 1 30 LIBERTY SHIP WAY SITE PLAN EXHIBIT 2 30 LIBERTY SHIP WAY 1 ST FLOOR REFERENCE PLAN EXHIBIT 3 30 LIBERTY SHIP WAY 2 ND FLOOR REFERENCE PLAN EXHIBIT 4 30 LIBERTY SHIP WAY 3 RD FLOOR REFERENCE PLAN

PARKING Summary Sheet A Facility Name: 30 Liberty Ship Way, Sausalito, CA 94965 Date: September 25, 2013 Parking: Where self-parking is provided f employees visits, each parking area/lot structure is required to have accessible parking spaces complying with the following table and with CBC Section 1129B. Total parking in area/lot structure Required minimum number of accessible spaces (including van) 1 to 25 1 26 to 50 2 51 to 75 3 76 to 100 4 101 to 150 5 151 to 200 6 201 to 300 7 301 to 400 8 401 to 500 9 501 to 1000 2 percent of total 1001 and over 20 plus 1 f each 100 over 1000 At outpatient units and facilities 10 percent At facilities specializing in treatment f 20 percent persons with mobility impairments Note: s required by the table need not be provided in the particular area/lot structure. They may be provided at a different location if equivalent greater accessibility, in terms of distance from an accessible entrance, user cost and convenience, is ensured. In addition, one in every six (**one in every eight per 2010 CBC and 1991 Standards see Safe Harb provisions) accessible spaces, but not less than one, must be served by an access aisle 8 ft. wide minimum and must be designated "Van Accessible". SURVEY INCLUDES: ID Name/location of parking lots surveyed ( key number on site plan) Total parking in lot PK1 Nth 18 Total accessible* provided Total van accessible provided Minimum required accessible* Minimum required van accessible East 47 1 1 South 35 4 1** West 11 TOTAL 111 5 5 1 * Including van accessible spaces **Two stalls are marked as van accessible in the south parking lot; however, only one of the spaces meets the requirements f a van accessible stall. See PK1 f additional infmation. Indicates the number of Survey Fms attached to Summary Sheet A in the field. Fm Fm Fm SF1 Parking 1 SF4 Curb Ramps SF5 Drinking Fountains SF6 Telephones SF7 Ramps SF11 Dos and Gates SF13 Elevats SF23 Hazards SECTION 1

PASSENGER LOADING ZONES Summary Sheet B Facility Name: 30 Liberty Ship Way, Sausalito, CA 94965 Date: September 25, 2013 Passenger Loading Zones Where passenger-loading zones are provided, at least one must be accessible and comply with CBC Section 1131B. Accessible passenger loading zones are to be identified by a sign bearing the International Symbol of Accessibility. Note: Valet parking facilities must provide an accessible passenger loading zone. SURVEY INCLUDES: ID PZ1 Name/location of passenger loading zone surveyed ( key number on site plan) PZ2 PZ3 **NOT APPLICABLE** Indicates the number of Survey Fms attached to Summary Sheet B in the field. Fm Fm Fm SF2 Passenger Loading SF4 Curb Ramps SF23 Hazards SECTION 2

EXTERIOR ROUTES OF TRAVEL Summary Sheet C Facility Name: 30 Liberty Ship Way, Sausalito, CA 94965 Date: September 25, 2013 Exteri Routes of Travel An accessible route of travel must connect the following elements. Accessible routes must, to the maximum extent feasible, coincide with the routes f the general public. See Survey Fm 3A f accessible routes of travel to the public right-of-way, if adjacent to the property line of the site. See Survey Fm 3B f accessible routes of travel within the property line. At least one exteri accessible route of travel complying with CBC Section 1127B, must be provided between: and: Public transptation stops Accessible entrance* Accessible parking spaces Accessible entrance* Passenger loading zones Accessible entrance* Public streets and sidewalks Accessible entrance* Key facilities** Primary area *** * Accessible entrance means a primary entrance to the area subject to this survey. ** Key facilities means sanitary facilities, signs, drinking fountains, and public telephones serving the area subject to this survey. *** Primary area means the specific area subject to this survey. SURVEY INCLUDES: ID Name/location of routes of travel ( key number on site plan) Between: And: 3A 3B ER1 Marinship Way 30 Liberty Ship Way 3A ER2 30 Liberty Ship Way Parking 30 Liberty Ship Way Entrances 3B CR1 Curb Ramps Indicates the number of Survey Fms attached to Summary Sheet C in the field. Fm Fm Fm SF3 Exteri Routes (A+B) 2 SF4 Curb Ramps 1 SF5 Drinking Fountains SF6 Telephones SF7 Ramps SF8 Stairs SF9 Platfm Lifts SF13 Elevats SF19 Signage SF23 Hazards SECTION 3

ENTRANCES Summary Sheet D Facility Name: 30 Liberty Ship Way, Sausalito, CA 94965 Date: September 25, 2013 Primary Entrances CBC Section 1134B.2.1 requires at least one primary entrance serving the primary area to be accessible. Accessible routes to these entrances must, to the maximum extent feasible, coincide with the routes f the general public. In addition, if an entrance nmally serves one me of the functions listed below, that entrance must also be accessible. o Public transptation stops o Accessible parking spaces o Passenger loading zones o Public streets and sidewalks o Key facilities Note: In new construction all entrances and all ground flo exits must be fully accessible. SURVEY INCLUDES: ID EN1 30 Liberty Ship Way, Main Entry (South) EN2 30 Liberty Ship Way, Stair #2 Exit Do Name/location of entrances ( key number on site plan) **30 Liberty Ship Way, all other exteri dos surveyed with individual suites See Summary Sheet F Rooms and s. Indicates the number of Survey Fms attached to Summary Sheet D in the field. Fm Fm Fm SF3 Exteri Routes (A+B) SF7 Ramps SF8 Stairs SF10 Entrances and Exits 2 SF11 Dos and Gates SF13 Elevats SF19 Signage SF23 Hazards SECTION 4

INTERIOR ROUTES OF TRAVEL Summary Sheet E Facility Name: 30 Liberty Ship Way, Sausalito, CA 94965 Date: September 25, 2013 Interi Routes of Travel An accessible route of travel must connect the accessible building facility entrances with all accessible spaces of the primary area and its key facilities. Accessible routes must, to the maximum extent feasible, coincide with the routes f the general public. If the primary area any of its key facilities is located on a level other than the ground flo level, an accessible elevat must provide access to that level. Elevat Exemption: Installation of an elevat is not required in an altered facility that is less than three sties has less than 3,000 square feet per sty, except with respect to any facility that houses a shopping center, a shopping mall, the professional office of a health care provider, a terminal, depot, other station used f specified public transptation an airpt passenger terminal. SURVEY INCLUDES: ID Name/location of routes of travel Survey Fm ( key number on site plan) IR1 Interi Route of Travel SF12 Lobbies & Crids, IR1 Stair #1 Do SF11 Dos and Gates, IR1 Stair #1 Do Stair #1 SF8 Stairs, IR1 Stair #1 Stair #2 Do SF11 Dos and Gates, IR1 Stair #2 Do Stair #2 SF8 Stairs, IR1 Stair #2 Elevat Drinking Fountain SF13 Elevat, IR1 SF5 Drinking Fountains, IR1 1 st IR2 2 nd Interi Route of Travel SF12 Lobbies & Crids, IR2 2 nd Outdo Deck Dos SF11 Dos and Gates, IR2 2 nd Deck Stair #1 Do SF11 Dos and Gates, IR2 Stair #1 Do Stair #2 Do SF11 Dos and Gates, IR2 Stair #2 Do Drinking Fountain SF5 Drinking Fountains, IR2 2 nd IR3 3 rd Interi Route of Travel SF12 Lobbies & Crids, IR3 3rd Outdo Deck Dos SF11 Dos and Gates, IR3 3 nd Deck Stair #1 Do SF11 Dos and Gates, IR3 Stair #1 Do Stair #2 Do SF11 Dos and Gates, IR3 Stair #2 Do Drinking Fountain SF5 Drinking Fountains, IR3 3rd SECTION 5

ROOMS AND SPACES Summary Sheet F Facility Name: 30 Liberty Ship Way, Sausalito, CA 94965 Date: September 25, 2013 Rooms and s All primary area rooms and spaces which are not specifically exempt by code which are not used solely as wk areas must be accessible. Areas that are used only by employees as wk areas must be designed and constructed so that individuals with disabilities can approach, enter, and exit the areas. Accessibility is not required to: (i) observation galleries used primarily f security purposes; (ii) nonoccupiable spaces accessed only by ladders, catwalks, crawl spaces, very narrow passageways, (iii) freight (non-passenger) elevats and frequented only by service personnel f repair purposes (e.g., elevat pits, elevat penthouses, piping equipment catwalks). Note: F lobbies, crids, assembly areas, and toilet rooms, see specific Summary Sheets. SURVEY INCLUDES: ID Room ID Wk area only? Indicate Yes No Survey Fm 1st RS1 3030 - UB Warehouse Yes SF11 Dos and Gates, RS1 UB Warehouse RS2 3010 Yes SF11 Dos and Gates, RS2 3010 Dos A & B RS3 3110 Yes SF11 Dos and Gates, RS3 3110 Dos A & B SF11 Dos and Gates, RS3 3110 Do C RS4 3160 Yes SF11 Dos and Gates, RS4 3160 Do A SF11 Dos and Gates, RS4 3160 Do B RS5 3150 Yes SF11 Dos and Gates, RS5 3150 Do A SF11 Dos and Gates, RS5 3150 Do B SF11 Dos and Gates, RS5 3150 Do C SF11 Dos and Gates, RS5 3150 Do D **Kitchen area located in 3150 37 Counters & 38 Sink with no knee clearance. RS6 3140 Yes SF11 Dos and Gates, RS6 3140 RS7 3060 Yes SF11 Dos and Gates, RS7 3060 Dos A & B 2 nd RS8 3200 Yes SF11 Dos and Gates, RS 8 3200 **Kitchen area located in 3200 37-1/2 Counter & Sink with no knee clearance under sink. RS9 3225 Yes SF11 Dos and Gates, RS 9 3225 RS10 3250 Yes SF11 Dos and Gates, RS 10 3250 3 rd RS11 3320 Yes SF11 Dos and Gates, RS11 3320 Do A SF11 Dos and Gates, RS11 3320 Do B **Kitchen area located in 3320 35-3/4 Counter & Sink with no knee clearance. SECTION 6

ROOMS AND SPACES Summary Sheet F Facility Name: 30 Liberty Ship Way, Sausalito, CA 94965 Date: September 25, 2013 RS12 3330 Yes SF11 Dos and Gates, RS12 3330 RS13 3360 Yes SF11 Dos and Gates, RS13 3360 Do A SF11 Dos and Gates, RS13 3360 Do B SF11 Dos and Gates, RS13 3360 Do C **Kitchen area located in 3360 34-1/2 Counter & Sink with no knee clearance. RS14 3380 Yes SF11 Dos and Gates, RS14 3380 **Employee wk areas above surveyed f general access only. SECTION 6

TOILET ROOMS Summary Sheet G Facility Name: 30 Liberty Ship Way, Sausalito, CA 94965 Date: September 25, 2013 Toilet Rooms Each public and common use toilet room must be accessible and comply with CBC Section 1115B. Employee toilet rooms are considered to be "common use" toilet rooms. In existing buildings facilities when compliance with building standards would create an unreasonable hardship, an exception may be granted when equivalent facilitation is provided. When equivalent facilitation is used, the following applies: (1) all sanitary facilities are not required to comply with building standards when accessible sanitary facilities are provided within a reasonable distance of accessible areas, and (2) signage is provided at inaccessible sanitary facilities indicating the location of the nearest accessible sanitary facilities. SURVEY INCLUDES (Survey Fm 16 Toilet Rooms): ID Name/location/function of toilet room Survey Fm ( key number on site plan) TR1 Women s Restroom & Shower 1 st SF16 Toilet Rooms, Women s 1st SF17 Shower Facility, Women s 1st TR2 Men s Restroom & Shower 1 st SF16 Toilet Rooms, Men s 1st SF17 Shower Facility, Men s 1st TR3 Women s Restroom & Shower 2 nd SF16 Toilet Rooms, Women s 2nd SF17 Shower Facility, Women s 2nd TR4 Men s Restroom & Shower 2 nd SF16 Toilet Rooms, Men s 2nd SF17 Shower Facility, Men s 2nd TR5 Women s Restroom & Shower 3rd SF16 Toilet Rooms, Women s 3rd SF17 Shower Facility, Women s 3rd TR6 Men s Restroom & Shower 3rd SF16 Toilet Rooms, Men s 3rd SF17 Shower Facility, Men s 3rd TR7 Women s Exteri Restroom SF16 Toilet Rooms, Women s Exteri TR8 Men s Exteri Restroom SF16 Toilet Rooms, Men s Exteri SECTION 7

ASSEMBLY USE AREAS Summary Sheet H Facility Name: 30 Liberty Ship Way, Sausalito, CA 94965 Date: September 25, 2013 Assembly Use Areas An assembly area is defined as a room space accommodating a group of individuals f recreational, educational, political, social, amusement purposes, f the consumption of food and drink, including conference and meeting rooms, stadiums, grandstands, bleachers, athletic pavilions, gymnasiums and miscellaneous spt-related facilities, auditiums, assembly halls, theaters and related facilities, such as stages, enclosed and unenclosed platfms, and chestra pits. Assembly use areas must comply with the general accessibility requirements and CBC Section 1104B. See Survey Fm 15A f rooms with fixed seating and large assembly areas, and Fm 15B f smaller meeting and conference rooms up to 750 square feet in size. SURVEY INCLUDES: ID Name/location/function of assembly area ( key number on site plan) 15A 15B AA1 AA2 AA3 AA4 AA5 AA6 AA7 AA8 AA9 AA10 Room On flo **NOT APPLICABLE** Indicates the number of Survey Fms attached to Summary Sheet H in the field. Fm Fm Fm SF5 Drinking Fountains SF6 Telephones SF7 Ramps SF8 Stairs SF9 Platfm Lifts SF10 Entrances and Exits SF11 Dos and Gates SF12 Lobbies and Crids SF15A Large Assembly SF15B Small Assembly SF19 Signage SF20 Alarms SF23 Hazards SECTION 8

ALARMS Summary Sheet I Facility Name: 30 Liberty Ship Way, Sausalito, CA 94965 Date: September 25, 2013 Alarm Systems If fire, evacuation, emergency warning systems are required provided at a building facility, then they must include both audible alarms and visual alarms complying with CBC Sections 907.5.2, 907.5.2.1, 907.5.2.2, 907.5.2.3 and 1114B.2.2. Emergency warning systems in medical care facilities, large assembly areas, and detention facilities may be modified to suit specific use and safety standards. SURVEY INCLUDES: ID AL1 Name of building facility (e.g., main building) Part of building facility (e.g., east wing) On flo Room AL2 AL3 **NOT APPLICABLE** Alarms not surveyed. Fire Alarm Systems to comply with NFPA 72. Indicates the number of Survey Fms attached to Summary Sheet I in the field. Fm Fm Fm SF20 Alarms SF23 Hazards SECTION 9

EXHIBITS Facility Name: 30 Liberty Ship Way, Sausalito, CA 94965 Summary Sheet J Date: September 25, 2013 ID Reference /Description 1 Exhibit 1 30 Liberty Ship Way Site Map 2 Exhibit 2 30 Liberty Ship Way 1 st Reference Plan 3 Exhibit 3 30 Liberty Ship Way 2 nd Reference Plan 4 Exhibit 4 30 Liberty Ship Way 3 rd Reference Plan Indicates the number of Survey Fms attached to Summary Sheet J in the field. Fm Fm Fm SECTION 10

PARKING Survey Fm 1 /Room Name: 30 Liberty Ship Way, Parking : PK1 : : 1.1 Number - Where parking spaces are provided f self-parking Accessible by employees visits both, is the required Parking s number of accessible parking spaces provided? (See Minimum Summary Sheet A) (Note: All some of the accessible parking spaces may be in a different location if equivalent greater accessibility is ensured.) 208.2 /// 1129B.1; 1129B.2; Table 11B-6 1.2 Each Area/Lot Are the accessible parking spaces located in each specific area/lot? OR If the accessible parking spaces are in a different location, is equivalent greater accessibility provided in terms of distance from the accessible entrance, user cost and convenience? 208.3 /// 1129B.1 1.3 Van Accessible s Is one in every six accessible parking spaces (but not less than one) designated "van accessible? 208.2.4 /// 1129B.3 item 2, 1129B.4 4 stalls located directly in front of entrance; another van accessible stall is located at the far Southeast cner of the parking lot. See Picture PK1-001. **1 in 8 required by 1991 Standards and CBC See Safe Harb Provisions 1.4 Location - Are accessible parking spaces which serve a Serving particular building on the shtest accessible route of Accessible travel from adjacent parking to the building's Entrance accessible entrance? 208.3 /// 1129B.1 1.5 Lot Layout Are parking stalls arranged so that persons with disabilities are not compelled to wheel walk behind parked cars other than their own? /// 1129B.3 item 3 1.6 Serving Multiple Accessible Entrances 1.7 Separate Parking Facility 1.8 Parking Width 1.9 Van Access Aisle If the building has multiple accessible entrances with adjacent parking, are the accessible parking spaces on the shtest accessible route of travel to the parking facility's accessible pedestrian entrance? 208.3 /// 1129B.1 Where a parking facility does not serve a particular building, are the accessible parking spaces on the shtest accessible route of travel to the parking facility's accessible pedestrian entrance? 208.3 /// 1129B.1 Are accessible parking spaces, including van spaces, at least 9 wide and 18 long with a demarcated access aisle? (two spaces may share a common aisle) 502.2 /// 1129B.3 items 1 & 2 If the parking space is designated as "van accessible," is the adjacent access aisle at least 8 wide by 18 long and located on the passenger side of the vehicle space? 502.3 /// 1129B.3 item 2 Yes with the exception of the stall at the Southeast cner. Yes with the exception of the stall at the Southeast cner. Accessible stalls located at Main Entrance. The right stall is not van accessible as the access aisle is on the driver s side and a van accessible stall requires the access aisle on the passenger side. Add an accessible stall at the front of the building on the South, West East side. See above. Add an accessible stall as noted above. Remove van accessible signage. This can still serve as one of the required accessible stalls. See Picture PK1-002. Page 1 of 3

PARKING Survey Fm 1 /Room Name: 30 Liberty Ship Way, Parking : PK1 : : 1.10 Car Access Aisles Are all other access aisles at least 5 wide and 18 long? 502.3 /// 1129B.3 item 1 1.11 Level Surface Are the accessible parking spaces and access aisles level with no slope greater than 2% in all directions? (This means a curb ramp cannot project into the access aisle.) 502.4 /// 1129B.3 items 3 & 4 1.12 Surface Are access aisles stable, firm, and slip resistant? 502.4 /// 1124B.1 1.13 Access Aisle and Accessible Route Does each access aisle connect directly to an accessible route of travel? (Use Fm 3 - Exteri Routes of Travel) 502.3 /// 1129B.1 1.14 Parking Does each accessible parking space have a reflectized sign (at least 70 sq in) visible from each stall showing the ISA and shall include an additional sign, language, below the symbol of accessibility stating Minimum Fine $250. 502.6 /// 1129B.4 1.15 Van Accessible Parking Do van accessible spaces have a sign stating "Van Accessible" below the ISA? 502.6 /// 1129B.4 1.16 Sign Height Are the signs 60 minimum above the finished flo ground surface measured to the bottom of sign; a minimum height of 80 from the bottom of the sign when located in a path of travel? 502.6 /// 1129B.4 1.17 Pavement Striping Is the loading and unloading access aisle marked by a bder painted blue? Within the blue bder, are hatched lines, a maximum of 36 on center, painted a col contrasting with the parking surface (preferably blue white)? /// 1129B.3 items 1 & 2 1.18 Pavement Sign Is there a 36 square ISA painted on the pavement at the rear of the stall? /// 1129B.4 1.19 Lettering Are the wds NO PARKING provided in each access aisle, painted in white, 12 high letters? /// 1129B.3 items 1 & 2 1.20 Tow-away Sign Is there a tow-away sign posted in a conspicuous place at each entrance to off street parking lot, immediately adjacent to and visible from each accessible stall? /// 1129B.4 1.21 Van Accessible s - Vertical Clearance Do van accessible spaces have a vertical clearance of at least 8-2? 502.5 /// 1130B Slopes range from 2.2% 2.5% in the right side accessible stalls. Slopes are good in the left accessible stalls. Slopes along accessible path of travel exceed 2%. Bottom of signs at 75-5/8. Level accessible parking and access isle so slopes do not exceed 2% in any direction. Level accessible path of travel so cross slopes do not exceed 2%. See 1.9 above. Raise accessible parking signs so that the bottom of the sign is a minimum of 80 above the ground surface. Install a tow-away sign at the driveway entrance that serves 30 Liberty Ship Way. Page 2 of 3

PARKING Survey Fm 1 /Room Name: 30 Liberty Ship Way, Parking : PK1 : : 1.22 Van Accessible s - Vertical Clearance Does one vehicular access route to and from van accessible spaces have a vertical clearance of at least 8-2? (Van accessible spaces may be grouped on one level of a parking structure.) 502.5 /// 1130B 1.23 Other NOTES: PK1-001 Remove Van Accessible Sign from this location. PK1-002 Page 3 of 3

EXTERIOR ROUTES OF TRAVEL (Public Rights-of-Way Only) Survey Fm 3A /Room Name: 30 Liberty Ship Way : ER1 : : 3.1A Accessible Route of Travel in the Public Right of Way Is there an accessible route of travel linking an accessible site entrance with the following, if provided and if adjacent to the property line of the site: public transptation stops, passenger loading zones, accessible parking, and public sidewalks? 206.2.1 /// 1114B.1.2 3.2A Width Is the accessible route of travel at least 48 wide except at doways gates? 403.5 /// 1133B.7.1 3.3A Surface Are accessible route surfaces stable, firm and slipresistant? 403.2 /// 1124B.1 3.4A Head Room Is there at least 80 clear head room within the pedestrian circulation area, including the accessible route of travel? 307 /// 1133B.8.6.2 3.5A Protruding Objects 3.6A Protruding Objects If wall-mounted objects have leading edges between 27 and 80 from the flo, do they project less than 4 into the circulation path (objects with leading edges at below 27 may project any amount)? If wall-mounted objects project into the circulation path, is the required clear width of the accessible route of travel maintained? 307.2 /// 1133B.8.6.1 Do free-standing objects mounted on posts with leading edges between 27 and 80 high (such as a sign telephone) overhang 12 less above the ground finish flo? If free-standing objects mounted on posts project into the circulation path, is the required clear width of the accessible route of travel maintained? 307.3 /// 1133B.8.6.1 3.7A Cross Slope Is the cross slope of the accessible route of travel no greater than 1:50 (2 percent)? 403.3 /// 1133B.7.1.3 3.8A Running Slope 3.9A Changes in Level Is the slope of the accessible route of travel no greater than 1:20 (5 percent), unless it complies with the requirements of a ramp it does not exceed the grade of the adjacent roadway? 403.3 /// 1133B.7.3 When walkway levels change abruptly, is the vertical distance between them less than 1/4 inch? OR Are changes in level between 1/4 inch and 1/2 inch beveled with a slope no greater than 1:2? 403.4 /// 1124B.2 Or See comments below in Notes section. Cross slopes exceed 2% (min) throughout all of the paths of travel. Consider landscaping/trees at paths from walking trail to south parking lot. x x Page 1 of 2

EXTERIOR ROUTES OF TRAVEL (Public Rights-of-Way Only) Survey Fm 3A /Room Name: 30 Liberty Ship Way : ER1 : : 3.10A Changes in Level 3.11A Grates and Drains 3.12A Hazardous Vehicular Areas - Detectable Warnings Are all curb ramps and ramps compliant? (See Fm 4 - Curb Ramps Fm 7 - Ramps) Is the smaller dimension of a grate opening in the accessible route of travel no me than 1/2 inch, and are long dimensions of rectangular gaps placed perpendicular to the usual direction of travel? 302.3 /// 1124B.4 If an accessible route of travel crosses adjoins the vehicular way and the walking surface is not separated by curbs, railings, other elements between the pedestrian areas and vehicular areas, is the boundary between the areas defined by a continuous detectable warning at least 36 wide complying with 1133B.8.5? Or Curb ramps at the sidewalk on the Nth Side of Liberty Ship Way, running East and West, at Buildings 28 and 30 drive way entrances, require detectable warning surfaces. Truncated domes do not separate pedestrian areas from vehicular areas typical through entire site. Install truncated domes at curb ramps as required per CBC 1127B.5 Install continuous truncated domes, 36 wide, where a pedestrian path conjoins crosses a vehicular way. 3.13A Other NOTES: South Side A bus stop is located at Bridgeway and Mariship Way. There is a sidewalk on the Nth side of Marinship Way that intersects with Liberty Ship Way; however, there is no sidewalk along Liberty Ship Way running in the East/West direction. A walking path diverts off Marinship Way which runs parallel along the South side of 10/20 Liberty Ship Way, 28 Liberty Ship Way and 30 Liberty Ship Way. Individual paths provide access from the walking path to the south parking lots of each building. Refer to Site Map Exhibit 1. Access from the walking path to the south side of 30 Liberty Ship Way does not have the 48 required clearance as there is a bollard installed in the center of the path. There is no defined path of travel from the walking path to the front entrance of the building. **An accessibility survey was not conducted on the sidewalk along Marinship Way the walking path running along the south side of 10/20, 28 30 Liberty Ship Way. Nth Side A 60 sidewalk runs along Liberty Ship Way in the East and West direction along the Nth property line of 28 Liberty Ship Way and 30 Liberty Ship Way. A sidewalk diverts from the street sidewalk to the edge of the site parking lot. A striped path of travel extends from the sidewalk to the Nthwest cner of 30 Liberty Ship Way. This path of travel will require detectable warning surfaces as noted in 3.12A above. Exception References : CBC 1127B Exteri Routes of Travel, Exception 2: In existing buildings, this section shall not apply in those conditions where, due to legal physical constraints, the site of the project would not allow compliance with these regulations equivalent facilitation without creating an unreasonable hardship. 2010 ADA Standards 206.2.1 Site Arrival Points, Exception 2: An accessible route shall not be required between site arrival points and the building facility entrance if the only means of access between them is a vehicular way not providing pedestrian access. Page 2 of 2

EXTERIOR ROUTES OF TRAVEL (On-Site Only) Survey Fm 3B /Room Name: 30 Liberty Ship Way : ER2 : : 3.1B On-site Accessible Route of Travel 3.2B Route f General Public 3.3B Facilities Connected Is there an accessible route of travel within the property line of the site linking an accessible building entrance with site arrival points serving the following, if provided: public transptation stops, passenger loading zones, accessible parking, and public sidewalks? 206.2.1 /// 1114B.1.2, 1127B.1 Does the accessible route of travel, to the maximum extent feasible, coincide with the route f the general public? 206.3 /// 1114B.1.2 Are there accessible routes of travel connecting all accessible buildings, facilities, elements and spaces on the same site with one another? 206.2.2 /// 1114B.1.2, 1127B.1 3.4B Width Is the accessible route of travel at least 48 wide except at doways gates? 403.5 /// 1133B.7.1 3.5B Passing s If the accessible route of travel is less than 60 wide, are there passing spaces at least 60 by 60 intersecting walks provided, allowing passing at reasonable intervals not exceeding 200? 403.5.3 /// 1133B.7.1 3.6B Head Room Is there at least 80 clear head room within the pedestrian circulation area, including the accessible route of travel? 307 /// 1133B.8.6.2 3.7B Protruding Objects 3.8B Protruding Objects If wall-mounted objects have leading edges between 27 and 80 from the flo, do they project less than 4 into the circulation path (objects with leading edges at below 27 may project any amount)? If wall-mounted objects project into the circulation path, is the required clear width of the accessible route of travel maintained? 307.2 /// 1133B.8.6.1 Do free-standing objects mounted on posts with leading edges between 27 and 80 high (such as a sign telephone) overhang 12 less above the ground finish flo? If free-standing objects mounted on posts project into the circulation path, is the required clear width of the accessible route of travel maintained? 307.3 /// 1133B.8.6.1 3.9B Cross Slope Is the cross slope of the accessible route of travel no greater than 1:50 (2 percent)? 403.3 /// 1133B.7.1.3 A path of travel is Designate an striped on the nth accessible path side of the building, of travel from the but a path of travel walking path to needs to be the front entrance defined from the walking path to the main entrance on the South side. See above. The path of travel from the walking path does not have 48 as there is a bollard installed in the middle of the path. See Picture ER2-001. Cross slopes exceed 2% (min) throughout all paths of travel. x x Page 1 of 4

EXTERIOR ROUTES OF TRAVEL (On-Site Only) Survey Fm 3B /Room Name: 30 Liberty Ship Way : ER2 : : 3.10B Running Slope 3.11B Running Slope 3.12B Changes in Level 3.13B Changes in Level Is the slope of the accessible route of travel no greater than 1:20 (5 percent), unless it complies with item 12 below? 403.3 /// 1133B.7.3 Where the slope is greater than 1:20 (5 percent), does it comply with the requirements f ramps? (See Fm 7 - Ramps) 405 /// 1133B.5 When walkway levels change, is the vertical distance between them less than 1/4 inch? OR Are changes in level between 1/4 inch and 1/2 inch beveled with a slope no greater than 1:2? 403.4 /// 1124B.2 Are curb ramps, ramps, elevats compliant? (See Fm 4 - Curb Ramps) 3.14B Surface Are accessible route surfaces stable, firm and slipresistant? 403.2 /// 1124B.1 3.15B Grates Is the smaller dimension of a grate opening no me than 1/2 inch, and are long dimensions of rectangular gaps placed perpendicular to the usual direction of travel? 302.3 /// 1124B.4 3.16B Abrupt Changes in Level >4 3.17B Abrupt Changes in Level >30 3.18B Entrance 3.19B Directions to Accessible Entrance Is the site free of abrupt changes in level adjacent to pedestrian areas exceeding 4 vertical except (1) between a walk sidewalk and an adjacent street driveway, (2) where a 6 high warning curb 42 high guard is provided to warn of a potential drop off? /// 1133B.8.1 Is the site free of abrupt changes in level adjacent to pedestrian areas exceeding 30 vertical except were a 42 high guard is provided to prevent persons from falling off the open edge? /// See 1013.1 f exceptions. Are signs at primary public entrances and at every maj junction where the accessible route of travel diverges from the regular circulation path compliant? 216.6 /// 1117B.5.8.1.2, 1127B.3 When not all entrances are accessible, is there directional signage indicating the accessible route to an accessible entrance? 216.6 /// 1117B.5.8.1.2 Curb ramps require detectable warnings.. Page 2 of 4

EXTERIOR ROUTES OF TRAVEL (On-Site Only) Survey Fm 3B /Room Name: 30 Liberty Ship Way : ER2 : : 3.20B Hazardous Vehicular Areas - Detectable Warnings If a walk crosses adjoins the vehicular way and the walking surface is not separated by curbs, railings, other elements between the pedestrian areas and vehicular areas, is the boundary between the areas defined by a continuous detectable warning at least 36 wide complying with1133b.8.5? The striped path of travel from the sidewalk on Liberty Ship Way to the Nthwest cner of the building will need detectable warning surfaces installed as noted in 3.20B above. See Picture ER2-002 below. Install continuous truncated domes, 36 wide, where a pedestrian path conjoins crosses a vehicular way. The walk surrounding 30 Liberty Ship Way is flush with the parking area, a curb detectable warning surfaces will need to be installed around the perimeter of the building to separate the pedestrian area from the vehicular area. See Picture ER2-003. 3.21B Other NOTES: ER2-001 Page 3 of 4

EXTERIOR ROUTES OF TRAVEL (On-Site Only) Survey Fm 3B /Room Name: 30 Liberty Ship Way : ER2 : : ER2-002 ER2-003 Page 4 of 4

CURB RAMPS Survey Fm 4 /Room Name: 30 Liberty Ship Way, Nth Sidewalk : CR1 : : 4.1 Curb Ramp Location Is there a curb ramp wherever an accessible route crosses a curb? 406 /// 1127B.5 item 1 4.2 Slope Is the slope of the curb ramp the least possible slope but in no case me than 8.3%? 406.1 /// 1127B.5 item 3 4.3 Transition Is the transition from the curb ramp to the road gutter flush and free of abrupt changes? 406.2 /// 1127B.5 item 3 4.4 Counter Slope Are the running slopes of the road, gutter accessible route adjoining the ramp no greater than 5%? 406.2 /// 1127B.5 item 3 4.5 Width Is the width of the curb ramp, not including the flared sides, at least 48? 406.1 /// 1127B.5 item 2 4.6 Surface Is the surface of the curb ramp stable, firm and slipresistant? 406.1 /// 1127B.5 item 5 4.7 Grooved Bder 4.8 Side Flare Slope 4.9 Side Flare Slope 4.10 Built-up Curb Ramps 4.11 Detectable Warning 4.12 Detectable Warning 4.13 Parked Vehicles 4.14 Curb Ramps at Crosswalks Is there a 12 grooved bder along the top and sides of the ramp at the level of the surface sidewalk? ///1127B.5 item 6 Do the flared sides have a slope of 10% less (measured along the curb)? 406.3 /// 1127B.5 item 3 Where the landing at the top of the ramp is less than 48 deep and wheelchair users must use the side flares f access, do the flared sides have a slope of 8.3% less (measured along the curb)? /// 1127B.5 item 4 Are built-up curb ramps located so that they do not project into vehicular traffic lanes parking access aisles? 406.5 /// 1127B.5 item 1, 1129B.3 items 3 & 4 Does the curb ramp have detectable warning? /// 1127B.5 item 7 Does the detectable warning consist of raised truncated domes, which contrast visually with adjoining surfaces (light-on-dark dark-on-light), and is the material used to provide contrast an integral part of the walking surface? /// 1127B.5 item 7 Are curb ramps located protected so that they will not be obstructed by parked vehicles? 502.7 ///1127B.5 item 8 Where pedestrian crossings are identified by lines, are curb ramps at wholly contained within the crosswalk lines, except f the flared sides? 406.6 /// 1127B.5 items 1 & 9 West Curb at 9.2% East Curb OK No truncated domes. Reconfigure curb ramp increase run length so max slope is 8.3%. Install truncated domes as noted below. Install as required. Page 1 of 2

CURB RAMPS Survey Fm 4 /Room Name: 30 Liberty Ship Way, Nth Sidewalk : CR1 : : 4.15 Bottom Landing Is the bottom 48 x 48 landing completely contained within the crosswalk lines? 406.6 /// 1127B.5 item 9 4.16 Straight Curb If the diagonal curb ramp has flared sides, is there at least a 24 segment of straight curb located on each side of the curb ramp within the crosswalk lines? 406.6 /// 1127B.5 item 9 4.17 Island Where the accessible route of travel crosses a median island, is the island curb cut through at street level? OR Are there curb ramps on both sides and a level area at least 48 long between them? 406.7 /// 4.18 Other NOTES: Page 2 of 2

BUILDING ENTRANCES AND EXITS Survey Fm 10 /Room Name: 30 Liberty Ship Way, Main Entrance : EN1 : : 10.1 Entrances Serving Site Arrival Points Is there at least one accessible entrance connected by an accessible route to each type of existing site arrival point (i.e.: public transptation stops, accessible parking and passenger loading zones, and public streets sidewalks)? (See Fm 3 - Exteri Routes of Travel) 206.4 /// 1114B.1.2 10.2 Entrance Sign Are all accessible entrances identified by an ISA? 216.6 /// 1117B.5.8.1.2 10.3 Directional Sign If an entrance is not accessible, are there directional signs indicating the location of the nearest accessible entrance? 216.6 /// 1117B.5.8.1.2 10.4 Dos At each accessible entrance to a building facility, is there at least one accessible do complying with the requirements below? 206.4 /// 1133B.1.1.1.1, 1133B.2 10.5 Clear Do Opening 10.6 Do Maneuvering 10.7 Do Maneuvering When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2 If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 10.8 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 10.9 Do Threshold Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 10.10 Do Hardware Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7 /// 1133B.2.5.2 Refer to Survey Fm 3B ER2. Exteri slope 2.2% at center of dos. Page 1 of 2

BUILDING ENTRANCES AND EXITS Survey Fm 10 /Room Name: 30 Liberty Ship Way, Main Entrance : EN1 : : 10.11 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 10.12 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 10.13 Tactile Exit 10.14 Tactile Exit 10.15 Tactile Exit 10.16 Directional Exit At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1; 4.30.1 /// 1011.3 item 3 & 4 Is there directional signage posted at all inaccessible exits indicating the direction to the nearest accessible exit? The sign must be located so that the route does not have to be retraced, and must comply with the requirements f visual signs. 216.4.3 /// 1007.10 >25lbs Adjust closer. Add signage per referenced code. 10.17 Other NOTES: Page 2 of 2

BUILDING ENTRANCES AND EXITS Survey Fm 10 /Room Name: 30 Liberty Ship Way, Stair #2 Exit : EN2 : : 10.1 Entrances Serving Site Arrival Points Is there at least one accessible entrance connected by an accessible route to each type of existing site arrival point (i.e.: public transptation stops, accessible parking and passenger loading zones, and public streets sidewalks)? (See Fm 3 - Exteri Routes of Travel) 206.4 /// 1114B.1.2 10.2 Entrance Sign Are all accessible entrances identified by an ISA? 216.6 /// 1117B.5.8.1.2 10.3 Directional Sign If an entrance is not accessible, are there directional signs indicating the location of the nearest accessible entrance? 216.6 /// 1117B.5.8.1.2 10.4 Dos At each accessible entrance to a building facility, is there at least one accessible do complying with the requirements below? 206.4 /// 1133B.1.1.1.1, 1133B.2 10.5 Clear Do Opening 10.6 Do Maneuvering 10.7 Do Maneuvering When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2 If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 10.8 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 10.9 Do Threshold Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 10.10 Do Hardware Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7 /// 1133B.2.5.2 Refer to Survey Fm 3B ER2. Exit Do Slopes at exteri do landing range from 2.4% to 3.4%. Page 1 of 2

BUILDING ENTRANCES AND EXITS Survey Fm 10 /Room Name: 30 Liberty Ship Way, Stair #2 Exit : EN2 : : 10.11 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 10.12 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 10.13 Tactile Exit 10.14 Tactile Exit 10.15 Tactile Exit 10.16 Directional Exit At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1; 4.30.1 /// 1011.3 item 3 & 4 Is there directional signage posted at all inaccessible exits indicating the direction to the nearest accessible exit? The sign must be located so that the route does not have to be retraced, and must comply with the requirements f visual signs. 216.4.3 /// 1007.10 >27 lbs Adjust closer. There is an EXIT sign installed at the 1 st flo crid do to stairwell. This should be an EXIT ROUTE sign. Add EXIT sign per referenced code. Install EXIT ROUTE sign at the 1 st flo crid do to the stairwell. 10.17 Other NOTES: Page 2 of 2

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 1 st Crid : IR1 : 1 st : 12.1 Accessible Route 12.2 Width - General Is there an accessible route of travel connecting accessible entrances with all accessible elements and spaces within the building? 206.2.4 /// 1114B.1.2 Is the accessible route of travel, except at doways, at least 44 wide where the occupancy load is 10, at least 36 where the occupancy load is <10? 403.5.1 /// 1133B.3.1 12.3 U-Turn Where the accessible route of travel makes a U-turn around an obstacle which is less than 48 wide, is the accessible route at least 42 wide on the approaches and 48 wide in the turn? 403.5.2 /// Fig 11B-5E 12.4 Surface Are the flo surfaces on the accessible route of travel stable, firm, and slip-resistant? 403.2 /// 1124B.1 12.5 Clear Do Opening 12.6 Do Maneuvering 12.7 Do Hardware 12.8 Do Operating Efft 12.9 Revolving Do When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? ( the N/A box if dos are being documented by another ption of your survey.) 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2 If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26A, B, C Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7/// 1133B.2.5.2 Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the revolving do turnstile to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.4 Yes, other than Adjust do do pressures and pressures as signage. required this is an on-going maintenance issue. Lobby Do Lobby Do Lobby Do Lobby Do >20 lbs Page 1 of 4

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 1 st Crid : IR1 : 1 st : 12.10 Other Do Do crid dos comply with all applicable requirements of Survey Fm 11 - Dos and Gates? 404 /// 1133B.1 12.11 Directional and Infmational 12.12 Room/ Identification 12.13 Tactile Exit 12.14 Tactile Exit 12.15 Tactile Exit Do signs which provide direction to, infmation about, functional spaces of the building comply with the requirement f visual signage? EXCEPTION: Building directies, menus, and all other signs which are tempary are not required to comply. 216 /// 1117B.5.1 item 2 Do signs which identify permanent rooms and spaces comply with the visual and tactile/braille requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 12.16 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 12.17 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 12.18 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 See individual suites f do surveys. See picture below. Suites have identification signage located on the approach side of the do, but exit signs are not installed. Not at all locations. See individual Suite surveys, and notes in 12.18 below. Electrical Room and Janit s Closet signage is mounted on the do and is not compliant. Install EXIT ROUTE sign at 1 st flo lobby do (crid side) and at do leading to exteri exit at Stair #1. Page 2 of 4

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 1 st Crid : IR1 : 1 st : 12.19 Raised and Braille Characters 12.20 Character Size Are the characters on tactile signs accompanied by Suite identification Grade 2 Braille? Is the Braille placed a min. of 3/8 and signage is not a max. of 1/2 below the tactile characters, flush left tactile. centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 Are the raised characters on tactile signs between 5/8 See above. and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 12.21 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 12.22 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 12.23 Other Identification Signage 12.24 Counter Height 12.25 Counter Knee 12.26 Changes in Level 12.27 Protruding Objects Does signage comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 At reception, transaction, security counters, is there a ption of the main counter at least 36 long and no me than 34 high? 227, 904.4 /// 1122B.4 Where seated service at a counter is provided, is the knee space at least 27 high, 30 wide, and 19 deep? 306.3 /// 1122B.3 Are ramps elevats used f changes in level greater than 1/2"? (Platfm lifts may only be used in certain limited situations.) 403.4 /// 1124B.2 If objects mounted to the wall have leading edges between 27 and 80 from the flo, do they project less than 4 into the circulation path? (Wall mounted objects with leading edges at below 27 may project any amount so long as the required clear width of an accessible route is not reduced.) 307 /// 1133B.8.6.1 12.28 Head room Is there at least 80 clear head room within the pedestrian circulation area, including the accessible route of travel? 307.4 /// 1133B.8.6.2 12.29 Alarms If emergency warning systems are provided, do they include both audible alarms and visual alarms complying with Survey Fm 20 - Alarms? 215 ///907.5.2.1, 907.5.2.3, 1114B.2.2 Suite identification signage is not in upper case lettering. Fire Alarm System not surveyed. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 12.30 Other Page 3 of 4

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 1 st Crid : IR1 : 1 st : NOTES: Sample Suite Identification Sign: No Tactile Characters (Typical throughout). Tactile characters to be in all capital letters (Typical throughout). JANITOR TEL/ELEC Page 4 of 4

DRINING FOUNTAINS Survey Fm 5 /Room 30 Liberty Ship Way Name: Drinking Fountain 1 st IR1 : DF - 1 : 1st : 5.1 Drinking Fountains 5.2 Drinking Fountains 5.3 Accessible Route Where there is only one drinking fountain area on a flo, is there one drinking fountain accessible to wheelchair users and one accessible to persons who have difficulty bending stooping (e.g. hi-lo drinking fountain)? 211.2 /// 1117B.1 item 1 Where there is me than one drinking fountain on a flo, are 50% wheelchair accessible? 211.3 /// 1117B.1 item 1 Is the accessible drinking fountain on an accessible route? 206.2.4 /// 1117B.1 item 1 5.4 Depth Is the drinking fountain a minimum of 18 inches and a maximum of 19 inches in depth? /// 1117B.1 item 2 5.5 Knee Is the knee clearance between the bottom of the apron and the flo at least 27 high, 30 wide, and 8 deep, the depth being taken from the front edge of the fountain back towards the wall post? 602.2 /// 1117B.1 item 2 5.6 Toe Is the toe clearance at least 9 high and 17 deep from the front edge of the fountain? 602.2 /// 1117B.1 item 2 5.7 Clear 5.8 Protruding Objects Is there a clear flo space at least 30 by 48 providing a fward approach (a side approach is not acceptable)? 602.2 /// 1117B.1 item 2 If a wall-mounted drinking fountain has a leading edge between 27 and 80 from the flo, does it project less than 4 inches into the circulation path? 602.1 /// 1117B.1 item 3 5.9 Spout Height Is the bubbler outlet no higher than 36 above the flo and is the water flow at least 4 high to allow the insertion of a cup under the flow of water? 602.4, 602.6 /// 1117B.1 item 4 5.10 Location Is the bubbler outlet located within 5 of the front of the unit, with a water flow trajecty parallel nearly parallel to the front edge? 602.6 /// 1117B.1 item 4,5 5.11 Controls - Location Are the controls front-mounted on the side located within 6 of the front edge? 602.3 /// 1117B.1 item 4 5.12 Operation Are the controls operable with one hand, and without tight grasping, pinching, twisting of the wrist, and is the fce to operate the controls no greater than 5 lbs? 602.3 /// 1117B.6 item 4 Comments 26-5/8 34-1/4 No water flow 5.13 Other NOTES: Page 1 of 1

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 1st Stair #1 Do : IR1 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Refer to Survey Fm 12 Building Lobbies and Crids: IR1. Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 1st Stair #1 Do : IR1 : 1 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 >17 lbs Adjust closer. Add EXIT ROUTE sign on stair side of do per requirements below. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 1st Stair #1 Do : IR1 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Page 3 of 3

STAIRS Survey Fm 8 /Room 30 Liberty Ship Way Name: Stair #1 IR1 : Stair #1 : : 8.1 Stairs Do public and common use interi and exteri stairs comply with the accessibility requirements below? 504 /// 1114B.1.1, 1133B.4 8.2 Risers/Treads Are the risers closed? 504.3 /// 1133B.4.5.2 8.3 Risers/Treads Are the treads unifm and at least 11 wide measured from riser to riser and are the risers all unifm and between 4 and 7 in height? 504.2 /// 1009.4, 1133B.4.5.1, 1133B.4.5.2 8.4 Col Strip Interi Stairs 8.5 Col Strip Exteri Stairs Is there a solid contrasting col stripe 2 wide parallel to and not me than 1 away from the nosing on the upper approach and the lower tread of the stairway? /// 1133B.4.4 Is there a solid contrasting col stripe 2 wide parallel to and not me than 1 away from the nosing on the upper approach and all treads of the stairway? /// 1133B.4.4 8.6 Nosings Do stair nosings project no me than 1-1/4 past the face of the riser below? Is the transition from the nosing to the riser free of abrupt edges? (The 2007 CBC requires that stair nosings project no me than 1-1/4. The 2001, 1998 & 1995 CBC required that stair nosings project no me than 1-1/2. There is no requirement to retroactively alter existing nosing projections of 1-1/2 when constructed in compliance with the building code in effect at the time of iginal construction.) 504.5 /// 1009.4.5, 1133B.4.5.3 8.7 Continuous Handrails Are there continuous handrails along both sides? 504.6, 505.2 /// 1133B.4.1.1 8.8 Handrails On dogleg switchback stairs, is the inside handrail continuous at landings? 505.3 /// 1133B.4.2.2 Exception 1 8.9 Handrail Extensions 8.10 Diameter and Clearance Do the handrails extend a min. of 12 beyond the top nosing and 12 plus the tread width, beyond the bottom nosing, and are the tops of handrails between 34 and 38 above the stair nosings? 505.10 /// 1133B.4.2.1, 1133B.4.2.2 Is the diameter of the handrail between 1-1/4 and 1-1/2 in cross-sectional nominal dimension equivalent, and is the clear space between handrails and walls exactly 1-1/2? 505.7 /// 1133B.4.2.5, 1133B.4.2.6 8.11 Stairway Width Is the width of the stairway a minimum of 44? Are stairways serving an area of rescue assistance at least 48 wide between handrails? 403.5.1 /// 1007.3, 1009.1 8.12 Hazards Are handrail edges free of sharp abrasive elements and do they have edges with a min. radius of 1/8? 505.8 /// 1133B.4.2.6 6-3/4 Riser 11-7/8 Tread 3/4 1-1/2 44 38 clear between handrails. Page 1 of 2

STAIRS Survey Fm 8 /Room 30 Liberty Ship Way Name: Stair #1 IR1 : Stair #1 : : 8.13 Tactile Designation 8.14 Tactile Exit Signage Are tactile flo designation signs located at each flo level landing in all enclosed stairways in buildings two me sties in height to identify the flo level; and at the exit discharge level, does the sign include a raised five pointed star? /// 1133B.4.3 At each exit do that leads directly to a grade-level exteri exit by means of a stairway identified by a tactile exit sign that states EXIT STAIR DOWN EXIT STAIR UP, as appropriate? /// 1011.3.2 No signage installed in stairwells. Provide tactile signage at each flo level landing. 8.15 Other NOTES: Page 2 of 2

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 1 st Stair #2 Do : IR1 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Refer to Survey Fm 12 Building Lobbies and Crids: IR1. Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 1 st Stair #2 Do : IR1 : 1 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 >20 lbs Adjust closer. EXIT sign is See 11.20 installed at the below. do, but should be EXIT ROUTE. Install EXIT ROUTE sign per requirements below. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 1 st Stair #2 Do : IR1 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Current sign to be replaced. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Page 3 of 3

STAIRS Survey Fm 8 /Room 30 Liberty Ship Way Name: Stair #2 IR1 : Stair #2 : : 8.1 Stairs Do public and common use interi and exteri stairs comply with the accessibility requirements below? 504 /// 1114B.1.1, 1133B.4 8.2 Risers/Treads Are the risers closed? 504.3 /// 1133B.4.5.2 8.3 Risers/Treads Are the treads unifm and at least 11 wide measured from riser to riser and are the risers all unifm and between 4 and 7 in height? 504.2 /// 1009.4, 1133B.4.5.1, 1133B.4.5.2 8.4 Col Strip Interi Stairs 8.5 Col Strip Exteri Stairs Is there a solid contrasting col stripe 2 wide parallel to and not me than 1 away from the nosing on the upper approach and the lower tread of the stairway? /// 1133B.4.4 Is there a solid contrasting col stripe 2 wide parallel to and not me than 1 away from the nosing on the upper approach and all treads of the stairway? /// 1133B.4.4 8.6 Nosings Do stair nosings project no me than 1-1/4 past the face of the riser below? Is the transition from the nosing to the riser free of abrupt edges? (The 2007 CBC requires that stair nosings project no me than 1-1/4. The 2001, 1998 & 1995 CBC required that stair nosings project no me than 1-1/2. There is no requirement to retroactively alter existing nosing projections of 1-1/2 when constructed in compliance with the building code in effect at the time of iginal construction.) 504.5 /// 1009.4.5, 1133B.4.5.3 8.7 Continuous Handrails Are there continuous handrails along both sides? 504.6, 505.2 /// 1133B.4.1.1 8.8 Handrails On dogleg switchback stairs, is the inside handrail continuous at landings? 505.3 /// 1133B.4.2.2 Exception 1 8.9 Handrail Extensions 8.10 Diameter and Clearance Do the handrails extend a min. of 12 beyond the top nosing and 12 plus the tread width, beyond the bottom nosing, and are the tops of handrails between 34 and 38 above the stair nosings? 505.10 /// 1133B.4.2.1, 1133B.4.2.2 Is the diameter of the handrail between 1-1/4 and 1-1/2 in cross-sectional nominal dimension equivalent, and is the clear space between handrails and walls exactly 1-1/2? 505.7 /// 1133B.4.2.5, 1133B.4.2.6 8.11 Stairway Width Is the width of the stairway a minimum of 44? Are stairways serving an area of rescue assistance at least 48 wide between handrails? 403.5.1 /// 1007.3, 1009.1 8.12 Hazards Are handrail edges free of sharp abrasive elements and do they have edges with a min. radius of 1/8? 505.8 /// 1133B.4.2.6 6-3/4 Riser 11-7/8 Tread 3/4 1-1/2 44 38 clear between handrails. Page 1 of 2

STAIRS Survey Fm 8 /Room 30 Liberty Ship Way Name: Stair #2 IR1 : Stair #2 : : 8.13 Tactile Designation 8.14 Tactile Exit Signage Are tactile flo designation signs located at each flo level landing in all enclosed stairways in buildings two me sties in height to identify the flo level; and at the exit discharge level, does the sign include a raised five pointed star? /// 1133B.4.3 At each exit do that leads directly to a grade-level exteri exit by means of a stairway identified by a tactile exit sign that states EXIT STAIR DOWN EXIT STAIR UP, as appropriate? /// 1011.3.2 No signage installed in stairwells. Provide tactile signage at each flo level landing. 8.15 Other NOTES: See notes on SF11 Dos and Gates IR3, Stair #2 Do. Landing width is 56 and only allows f 15 at the pull side of the do to the leading edge of the stair. 15 56 Page 2 of 2

ELEVATORS Survey Fm 13 /Room Name: 30 Liberty Ship Way, Elevat IR1 : Elevat : : 13.1 Multi-level Building Does an elevat serve each level, including mezzanines? F exceptions see 1103B.1. (If a ramp a platfm lift is provided instead, use Survey Fm 7 - Ramps and Survey Fm 9 - Platfm Lifts.) 407.1 /// 1103B.1 13.2 Elevats If me than one elevat is provided in a building, does each full passenger elevat comply with the requirements below? 206.6, 407.1 /// 1103B.1 13.3 Hizontal Gap Is the hizontal gap between the car flo platfm and the landing edge no greater than 1-1/4? 407.4.3 /// 1116B.1.2 13.4 Hallway Call Buttons 13.5 Visual Indicats Are the hallway call buttons centered at 42 above the flo and are the buttons at least 3/4 in the smallest dimension? 407.2.1.1, 407.2.1.2 /// 1116B.1.10 Do the buttons have visual signals to indicate when each call is registered and answered and are the buttons raised flush (not recessed)? 407.2.1, 407.2.1.5 /// 1116B.1.10 1-3/8 1 st 42 2 nd 41-3/4 3 rd 41-7/8 13.6 Hall Lanterns Is there a visible and audible signal at each hoist way Applies to multiple entrance to indicate which car is answering a call and elevats. direction of travel? 407.2.2.1 /// 1116B.1.13 13.7 Audible Signals Do audible signals sound once f "up" and twice f "down," do they have verbal annunciats that say "up" "down"? 407.2.2.3 /// 1116B.1.13 13.8 Visible Signals Are visible signals also provided and are they: Mounted so that the centerline is at least 72 AFF; At least 2-1/2 in the smallest dimension; and, visible from the vicinity of the hall call button? 407.2.2.2 /// 1116B.1.13, Fig. 11B-40C 13.9 Do Jamb - Raised Characters 13.10 Do Jamb - Braille Does each elevat hoist way entrance have raised flo designation letters numerals, sans serif simple serif type, 2 high on each do jamb centered 60 AFF, and do the signs f the main entry flo include a raised star? 407.2.3 /// 1116B.1.14 Is Grade 2 Braille placed below the cresponding raised characters symbols? 407.2.3 /// 1116B.1.14, 1117B.5.6 **2010 ADA Standards, 703.3.2 Position [Braille], Exception: Braille provided on elevat car controls shall be separated 3/16 minimum and shall be located either directly below adjacent to the cresponding raised characters symbols. 13.11 Dos Do the dos re-open automatically without contact if an obstruction passes through the opening between 5 and 29 above the flo? 407.3.3 /// 1116B.1.5 Chimes once f both directions. Braille is located to the side of the raised character (similar to 28 Liberty Ship Way). **See code exception reference. Page 1 of 3

ELEVATORS Survey Fm 13 /Room Name: 30 Liberty Ship Way, Elevat IR1 : Elevat : : 13.12 Do Opening Is the clear opening at elevat dos at least 36? 407.3.6 /// 1116B.1.4 13.13 Car Inside Does the flo area of the car allow maneuvering room f wheelchair users to enter the car, reach the controls, turn, and exit? 407.4.1 /// 1116B.1.8 13.14 Center Opening Car Dos 13.15 Side-slide Opening Car Dos At cars with center opening dos, is the clear distance between walls between wall and do, excluding return panels, at least 80 by 54, and is the distance from wall to return panel at least 51 clear? Fig. 407.4.1 (a) /// 1116B.1.8, Fig 11B-40A At cars with side-slide opening dos, is the clear distance between walls between wall and do, excluding return panels, at least 68 by 54, and is the distance from wall to return panel at least 51 clear? Fig. 407.4.1 (b) /// 1116B.1.8, Fig 11B-40A 13.16 Handrail Is there a handrail installed at 32 AFF (+/-1 ), on at least one wall of the car? /// 1116B.1.11 13.17 Car Control Buttons 13.18 Car Controls - Raised Characters 13.19 Car Controls - Character Height 13.20 Car Controls - Braille 13.21 Car Controls - Contrast 13.22 Car Controls Main Entry Designation Are the car control buttons at least 3/4 in their smallest dimension, raised with square edges, and self-illuminated? 407.4.6.2.1 /// 1116B.1.9 Are the controls designated by raised letters and/ numerals, standard elevat symbols that are placed immediately to the left of the buttons? 407.4.7.1.2 /// 1116B.1.9 Are these raised characters upper case, sans serif simple serif, and at least 5/8 high? 407.4.7.1.1 /// 1116B.1.9 Is Grade 2 Braille placed below the cresponding raised characters symbols? 407.4.7.1.2 /// 1116B.1.9, 1117B.5.6 Are the raised characters white on a black background? /// 1116B.1.9 Is the button f the main entry flo designated by a raised star? 407.4.7.1.3 /// 1116B.1.9 13.23 Buttons Do the flo buttons have visual indicats to show when each call is registered and are they extinguished when each call is answered? 407.4.7.1.4 /// 1116B.1.8 13.24 Height of Car Controls 13.25 Emergency Car Controls Are the flo buttons no higher than 54 AFF f side approach and no higher than 48 when only front approach is possible? 407.4.6.1 /// 1116B.1.8 Are the emergency controls grouped at the bottom of the panel with centerlines no less than 35 AFF? 407.4.6.4 /// 1116B.1.8 46-3/4 68-3/16 x 95-1/16 31 to top 1 x1 35 Page 2 of 3

ELEVATORS Survey Fm 13 /Room Name: 30 Liberty Ship Way, Elevat IR1 : Elevat : : 13.26 Car Control Location 13.27 Emergency Communication 13.28 Emergency Communication 13.29 Emergency Communication If the cars have center opening dos, are the controls located on the front wall? OR If the cars have side-slide opening dos are the controls located on the side front wall adjacent to the dos? 407.4.6 /// 1116B.1.6, Fig 11B-40A Is there an emergency two-way communication system between the elevat and a point outside the hoistway provided? 407.4.9 /// 1116B.1.8 Is the highest operable part of the communication system no higher than 48 AFF, and if the system uses a handset, is the length of the cd from the panel to the handset at least 29? 407.4.9 /// 1116B.1.8 Is the 2-way communication system usable without voice communication? 407.4.9 /// 1116B.1.8 13.30 Controls If the communication system is in a closed compartment, is the hardware on the compartment do operable with one hand, and without tight grasping, pinching, twisting of the wrist? 407.4.9 /// 1116B.1.8, 1117B.6 item 4 Other Magnet NOTES: Page 3 of 3

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 2nd : IR2 : 2nd : 12.1 Accessible Route 12.2 Width - General Is there an accessible route of travel connecting accessible entrances with all accessible elements and spaces within the building? 206.2.4 /// 1114B.1.2 Is the accessible route of travel, except at doways, at least 44 wide where the occupancy load is 10, at least 36 where the occupancy load is <10? 403.5.1 /// 1133B.3.1 12.3 U-Turn Where the accessible route of travel makes a U-turn around an obstacle which is less than 48 wide, is the accessible route at least 42 wide on the approaches and 48 wide in the turn? 403.5.2 /// Fig 11B-5E 12.4 Surface Are the flo surfaces on the accessible route of travel stable, firm, and slip-resistant? 403.2 /// 1124B.1 12.5 Clear Do Opening 12.6 Do Maneuvering 12.7 Do Hardware 12.8 Do Operating Efft 12.9 Revolving Do When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? ( the N/A box if dos are being documented by another ption of your survey.) 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2 If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26A, B, C Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7/// 1133B.2.5.2 Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the revolving do turnstile to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.4 Yes, other than Adjust do do pressures and pressures as signage. required this is an on-going maintenance issue. Lobby Dos Lobby Dos Not Surveyed on hold opens. Same as above. Page 1 of 4

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 2nd : IR2 : 2nd : 12.10 Other Do Do crid dos comply with all applicable requirements of Survey Fm 11 - Dos and Gates? 404 /// 1133B.1 12.11 Directional and Infmational 12.12 Room/ Identification 12.13 Tactile Exit 12.14 Tactile Exit 12.15 Tactile Exit Do signs which provide direction to, infmation about, functional spaces of the building comply with the requirement f visual signage? EXCEPTION: Building directies, menus, and all other signs which are tempary are not required to comply. 216 /// 1117B.5.1 item 2 Do signs which identify permanent rooms and spaces comply with the visual and tactile/braille requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 12.16 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 12.17 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 12.18 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 See individual suites f do surveys. See picture below. 2 nd Suites have identification signage located on the approach side of the do, but exit signs are not installed. Not at all locations. See individual Suite surveys, and notes in 12.18 below. Electrical Room and Janit s Closet signage is mounted on the do and is not compliant. Page 2 of 4

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 2nd : IR2 : 2nd : 12.19 Raised and Braille Characters 12.20 Character Size Are the characters on tactile signs accompanied by Suite identification Grade 2 Braille? Is the Braille placed a min. of 3/8 and signage is not a max. of 1/2 below the tactile characters, flush left tactile. centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 Are the raised characters on tactile signs between 5/8 See above. and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 12.21 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 12.22 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 12.23 Other Identification Signage 12.24 Counter Height 12.25 Counter Knee 12.26 Changes in Level 12.27 Protruding Objects Does signage comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 At reception, transaction, security counters, is there a ption of the main counter at least 36 long and no me than 34 high? 227, 904.4 /// 1122B.4 Where seated service at a counter is provided, is the knee space at least 27 high, 30 wide, and 19 deep? 306.3 /// 1122B.3 Are ramps elevats used f changes in level greater than 1/2"? (Platfm lifts may only be used in certain limited situations.) 403.4 /// 1124B.2 If objects mounted to the wall have leading edges between 27 and 80 from the flo, do they project less than 4 into the circulation path? (Wall mounted objects with leading edges at below 27 may project any amount so long as the required clear width of an accessible route is not reduced.) 307 /// 1133B.8.6.1 12.28 Head room Is there at least 80 clear head room within the pedestrian circulation area, including the accessible route of travel? 307.4 /// 1133B.8.6.2 12.29 Alarms If emergency warning systems are provided, do they include both audible alarms and visual alarms complying with Survey Fm 20 - Alarms? 215 ///907.5.2.1, 907.5.2.3, 1114B.2.2 Suite identification signage is not in upper case lettering. 2 nd Break Room Counter and Sink at 34-1/2 with no knee clearance. Fire Alarm System not surveyed. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 12.30 Other Page 3 of 4

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 2nd : IR2 : 2nd : NOTES: Sample Suite Identification Sign: No Tactile Characters (Typical throughout). Tactile characters to be in all capital letters (Typical throughout). 2nd Break Room Page 4 of 4

DRINING FOUNTAINS Survey Fm 5 /Room 30 Liberty Ship Way Name: Drinking Fountain 2nd IR2 : DF - 2 : 2nd : 5.1 Drinking Fountains 5.2 Drinking Fountains 5.3 Accessible Route Where there is only one drinking fountain area on a flo, is there one drinking fountain accessible to wheelchair users and one accessible to persons who have difficulty bending stooping (e.g. hi-lo drinking fountain)? 211.2 /// 1117B.1 item 1 Where there is me than one drinking fountain on a flo, are 50% wheelchair accessible? 211.3 /// 1117B.1 item 1 Is the accessible drinking fountain on an accessible route? 206.2.4 /// 1117B.1 item 1 5.4 Depth Is the drinking fountain a minimum of 18 inches and a maximum of 19 inches in depth? /// 1117B.1 item 2 5.5 Knee Is the knee clearance between the bottom of the apron and the flo at least 27 high, 30 wide, and 8 deep, the depth being taken from the front edge of the fountain back towards the wall post? 602.2 /// 1117B.1 item 2 5.6 Toe Is the toe clearance at least 9 high and 17 deep from the front edge of the fountain? 602.2 /// 1117B.1 item 2 5.7 Clear 5.8 Protruding Objects Is there a clear flo space at least 30 by 48 providing a fward approach (a side approach is not acceptable)? 602.2 /// 1117B.1 item 2 If a wall-mounted drinking fountain has a leading edge between 27 and 80 from the flo, does it project less than 4 inches into the circulation path? 602.1 /// 1117B.1 item 3 5.9 Spout Height Is the bubbler outlet no higher than 36 above the flo and is the water flow at least 4 high to allow the insertion of a cup under the flow of water? 602.4, 602.6 /// 1117B.1 item 4 5.10 Location Is the bubbler outlet located within 5 of the front of the unit, with a water flow trajecty parallel nearly parallel to the front edge? 602.6 /// 1117B.1 item 4,5 5.11 Controls - Location Are the controls front-mounted on the side located within 6 of the front edge? 602.3 /// 1117B.1 item 4 5.12 Operation Are the controls operable with one hand, and without tight grasping, pinching, twisting of the wrist, and is the fce to operate the controls no greater than 5 lbs? 602.3 /// 1117B.6 item 4 Comments 26-5/8 34-3/8 5.13 Other NOTES: Page 1 of 1

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 2 nd Deck Dos : IR2 : 2 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Refer to Survey Fm 12 Building Lobbies and Crids: IR2. Slopes OK Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 2 nd Deck Dos : IR2 : 2 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 >20 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 2 nd Deck Dos : IR2 : 2 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 2 nd Stair #1 Do : IR2 : 2 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Refer to Survey Fm 12 Building Lobbies and Crids: IR2. Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 2 nd Stair #1 Do : IR2 : 2 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 >23 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 2 nd Stair #1 Do : IR2 : 2 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 2 nd Stair #2 Do : IR2 : 2 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Refer to Survey Fm 12 Building Lobbies and Crids: IR2. Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 2 nd Stair #2 Do : IR2 : 2 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 >23 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 2 nd Stair #2 Do : IR2 : 2 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Page 3 of 3

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 3rd Crid : IR3 : 3rd : 12.1 Accessible Route 12.2 Width - General Is there an accessible route of travel connecting accessible entrances with all accessible elements and spaces within the building? 206.2.4 /// 1114B.1.2 Is the accessible route of travel, except at doways, at least 44 wide where the occupancy load is 10, at least 36 where the occupancy load is <10? 403.5.1 /// 1133B.3.1 12.3 U-Turn Where the accessible route of travel makes a U-turn around an obstacle which is less than 48 wide, is the accessible route at least 42 wide on the approaches and 48 wide in the turn? 403.5.2 /// Fig 11B-5E 12.4 Surface Are the flo surfaces on the accessible route of travel stable, firm, and slip-resistant? 403.2 /// 1124B.1 12.5 Clear Do Opening 12.6 Do Maneuvering 12.7 Do Hardware 12.8 Do Operating Efft 12.9 Revolving Do When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? ( the N/A box if dos are being documented by another ption of your survey.) 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2 If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26A, B, C Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7/// 1133B.2.5.2 Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the revolving do turnstile to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.4 Yes, other than Adjust do do pressures and pressures as signage. required this is an on-going maintenance issue. Lobby Dos Lobby Dos Not Surveyed on hold opens. Same as above. Page 1 of 4

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 3rd Crid : IR3 : 3rd : 12.10 Other Do Do crid dos comply with all applicable requirements of Survey Fm 11 - Dos and Gates? 404 /// 1133B.1 12.11 Directional and Infmational 12.12 Room/ Identification 12.13 Tactile Exit 12.14 Tactile Exit 12.15 Tactile Exit Do signs which provide direction to, infmation about, functional spaces of the building comply with the requirement f visual signage? EXCEPTION: Building directies, menus, and all other signs which are tempary are not required to comply. 216 /// 1117B.5.1 item 2 Do signs which identify permanent rooms and spaces comply with the visual and tactile/braille requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 12.16 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 12.17 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 12.18 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 See individual suites f do surveys. See picture below. 3 rd Suites have identification signage located on the approach side of the do, but exit signs are not installed. Not at all locations. See individual Suite surveys, and notes in 12.18 below. Electrical Room and Janit s Closet signage is mounted on the do and is not compliant. Page 2 of 4

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 3rd Crid : IR3 : 3rd : 12.19 Raised and Braille Characters 12.20 Character Size Are the characters on tactile signs accompanied by Suite identification Grade 2 Braille? Is the Braille placed a min. of 3/8 and signage is not a max. of 1/2 below the tactile characters, flush left tactile. centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 Are the raised characters on tactile signs between 5/8 See above. and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 12.21 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 12.22 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 12.23 Other Identification Signage 12.24 Counter Height 12.25 Counter Knee 12.26 Changes in Level 12.27 Protruding Objects Does signage comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 At reception, transaction, security counters, is there a ption of the main counter at least 36 long and no me than 34 high? 227, 904.4 /// 1122B.4 Where seated service at a counter is provided, is the knee space at least 27 high, 30 wide, and 19 deep? 306.3 /// 1122B.3 Are ramps elevats used f changes in level greater than 1/2"? (Platfm lifts may only be used in certain limited situations.) 403.4 /// 1124B.2 If objects mounted to the wall have leading edges between 27 and 80 from the flo, do they project less than 4 into the circulation path? (Wall mounted objects with leading edges at below 27 may project any amount so long as the required clear width of an accessible route is not reduced.) 307 /// 1133B.8.6.1 12.28 Head room Is there at least 80 clear head room within the pedestrian circulation area, including the accessible route of travel? 307.4 /// 1133B.8.6.2 12.29 Alarms If emergency warning systems are provided, do they include both audible alarms and visual alarms complying with Survey Fm 20 - Alarms? 215 ///907.5.2.1, 907.5.2.3, 1114B.2.2 Suite identification signage is not in upper case lettering. 3 rd Break Room Counter and Sink at 34-1/2 with no knee clearance. Fire Alarm System not surveyed. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 12.30 Other Page 3 of 4

BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 30 Liberty Ship Way 3rd Crid : IR3 : 3rd : NOTES: Sample Suite Identification Sign: No Tactile Characters (Typical throughout). Tactile characters to be in all capital letters (Typical throughout). No Braille (some locations) 3 rd Break Room Page 4 of 4

DRINING FOUNTAINS Survey Fm 5 /Room 30 Liberty Ship Way Name: Drinking Fountain 3rd IR3 : DF - 3 : 3rd : 5.1 Drinking Fountains 5.2 Drinking Fountains 5.3 Accessible Route Where there is only one drinking fountain area on a flo, is there one drinking fountain accessible to wheelchair users and one accessible to persons who have difficulty bending stooping (e.g. hi-lo drinking fountain)? 211.2 /// 1117B.1 item 1 Where there is me than one drinking fountain on a flo, are 50% wheelchair accessible? 211.3 /// 1117B.1 item 1 Is the accessible drinking fountain on an accessible route? 206.2.4 /// 1117B.1 item 1 5.4 Depth Is the drinking fountain a minimum of 18 inches and a maximum of 19 inches in depth? /// 1117B.1 item 2 5.5 Knee Is the knee clearance between the bottom of the apron and the flo at least 27 high, 30 wide, and 8 deep, the depth being taken from the front edge of the fountain back towards the wall post? 602.2 /// 1117B.1 item 2 5.6 Toe Is the toe clearance at least 9 high and 17 deep from the front edge of the fountain? 602.2 /// 1117B.1 item 2 5.7 Clear 5.8 Protruding Objects Is there a clear flo space at least 30 by 48 providing a fward approach (a side approach is not acceptable)? 602.2 /// 1117B.1 item 2 If a wall-mounted drinking fountain has a leading edge between 27 and 80 from the flo, does it project less than 4 inches into the circulation path? 602.1 /// 1117B.1 item 3 5.9 Spout Height Is the bubbler outlet no higher than 36 above the flo and is the water flow at least 4 high to allow the insertion of a cup under the flow of water? 602.4, 602.6 /// 1117B.1 item 4 5.10 Location Is the bubbler outlet located within 5 of the front of the unit, with a water flow trajecty parallel nearly parallel to the front edge? 602.6 /// 1117B.1 item 4,5 5.11 Controls - Location Are the controls front-mounted on the side located within 6 of the front edge? 602.3 /// 1117B.1 item 4 5.12 Operation Are the controls operable with one hand, and without tight grasping, pinching, twisting of the wrist, and is the fce to operate the controls no greater than 5 lbs? 602.3 /// 1117B.6 item 4 Comments 27 35 5.13 Other NOTES: Page 1 of 1

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3rd Deck Dos : IR3 : 3 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Refer to Survey Fm 12 Building Lobbies and Crids: IR3. 2.5% - 2.7% slope to patio drain. Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3rd Deck Dos : IR3 : 3 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 >24 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3rd Deck Dos : IR3 : 3 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3rd Stair #1 Do : IR3 : 3 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Refer to Survey Fm 12 Building Lobbies and Crids: IR3. Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3rd Stair #1 Do : IR3 : 3 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 >17 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3rd Stair #1 Do : IR3 : 3 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3rd Stair #2 Do : IR3 : 3 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Refer to Survey Fm 12 Building Lobbies and Crids: IR3. 15 on pull side of do to leading edge of stairs. Stair landing width is 56. See SF8 IR1, Stair #2 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3rd Stair #2 Do : IR3 : 3 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 >20 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3rd Stair #2 Do : IR3 : 3 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3030 - UB Warehouse : RS1 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 Exteri Do Interi Double Dos Exteri Do Interi Double Dos Exteri Do Slopes: 1.6% - 2.3% Interi Double Dos: OK 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 Page 1 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3030 - UB Warehouse : RS1 : 1 : 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 Exteri Do Interi Double Dos Exteri Do Interi Double Dos Exteri Do Interi Double Dos Exteri Do: 15 lbs Interi Double Dos: >20 lbs 11.14 Do Closers If the do has a closer, is the closer adjusted so that Exteri Do from an open position of 70 degrees, the do will Interi Double take at least 3 seconds to move to a point 3 from the Dos latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 Exteri Do Interi Double Dos Personal Stage Exteri Do Adjust closer. Add EXIT sign per requirements below. Page 2 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3030 - UB Warehouse : RS1 : 1 : 11.20 Tactile Exit 11.21 Tactile Exit At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 Interi Double Do Add EXIT ROUTE sign per requirements below. See above. Page 3 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3030 - UB Warehouse : RS1 : 1 : 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: This area is a private lease space and was surveyed f an accessible exteri entrance/exit only. Page 4 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3010 : RS2 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 Do A Do B Do A Do B Do A Exteri Slopes: 2.0% - 2.3% Do B Exteri Slopes: 3.5% - 3.0% Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3010 : RS2 : 1 : 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 Do A Do B Do A Do B Do A Do B Not measured, but do pressure will exceed 5 lbs f both dos. Not measured. Do A Do B Do A Do B Adjust closer. Add EXIT sign per requirements below. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3010 : RS2 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 11.30 Other If one of the exteri dos is used as a public entrance to the suite, install an ISA sign. See SF10 EN1, 10.2 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3110 Exteri Dos A & B : RS3 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 Do A Do B Do A Do B Do A Exteri Slopes: OK Do B Exteri Slopes: 2.1% - 2.7% Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3110 Exteri Dos A & B : RS3 : 1 : 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 Do A Do B Do A Do B Do A Do B Do A: 17 lbs Do B: 21 lbs 11.14 Do Closers If the do has a closer, is the closer adjusted so that Do A from an open position of 70 degrees, the do will Do B take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 Do A Do B Do A Do B Adjust closer. Add EXIT sign per requirements below. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3110 Exteri Dos A & B : RS3 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 11.30 Other If one of the exteri dos is used as a public entrance to the suite, install an ISA sign. See SF10 EN1, 10.2 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3110 Do C : RS3 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Shelving reduces crid width to 42. Pull side of do requires 60. See picture below. Page 1 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3110 Do C : RS3 : 1 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 22 lbs Adjust closer. Page 2 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3110 Do C : RS3 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 No tactile characters. Not upper case. Signage does not meet current regulations. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other Page 3 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3110 Do C : RS3 : 1 : NOTES: 42 Page 4 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3160 Do A : RS4 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Exteri Slopes: 2.3% - 3.4% Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3160 Do A : RS4 : 1 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 20 lbs Adjust closer. Add EXIT sign per requirements below. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3160 Do A : RS4 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 11.30 Other If the exteri dos is used as a public entrance to the suite, install an ISA sign. See SF10 EN1, 10.2 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3160 Do B : RS4 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3160 Do B : RS4 : 1 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 21 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3160 Do B : RS4 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 No tactile characters. Not upper case. Signage does not meet current regulations. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Interi space not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do A : RS5 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Exteri Slopes: 2.4% - 2.7% Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do A : RS5 : 1 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 20 lbs Adjust closer. Add EXIT sign per requirements below. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do A : RS5 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 11.30 Other If the exteri dos is used as a public entrance to the suite, install an ISA sign. See SF10 EN1, 10.2 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do B : RS5 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Cubicle placement limits pull side of do to 41-1/2 when 60 is required. See picture below. Slopes OK Page 1 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do B : RS5 : 1 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 20 lbs Adjust closer. Add EXIT sign per requirements below. Page 2 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do B : RS5 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 11.30 Other If the exteri dos is used as a public entrance to the suite, install an ISA sign. See SF10 EN1, 10.2 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. Page 3 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do B : RS5 : 1 : NOTES: 41-1/2 Page 4 of 4

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do C : RS5 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Exteri Slopes: 2.8% Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do C : RS5 : 1 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 19 lbs Adjust closer. Add EXIT sign per requirements below. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do C : RS5 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 11.30 Other If the exteri dos is used as a public entrance to the suite, install an ISA sign. See SF10 EN1, 10.2 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do D : RS5 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do D : RS5 : 1 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 20 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3150 Do D : RS5 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 No tactile characters. Not upper case. Signage does not meet current regulations. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Interi space not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3140 : RS6 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Slopes OK Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3140 : RS6 : 1 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 21 lbs Adjust closer. Add EXIT sign per requirements below. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3140 : RS6 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 11.30 Other If the exteri dos is used as a public entrance to the suite, install an ISA sign. See SF10 EN1, 10.2 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3060 Exteri Dos A & B : RS7 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering 11.7 Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 Do A Do B Do A Do B Do A Exteri Slopes: 2.3% - 2.4% 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 Do B Exteri Slopes: 2.2% Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3060 Exteri Dos A & B : RS7 : 1 : 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 Do A Do B Do A Do B Do A Do B Do A: 21 lbs Do B: 19 lbs 11.14 Do Closers If the do has a closer, is the closer adjusted so that Do A: OK from an open position of 70 degrees, the do will Do B: Fast take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 Do A Do B Do A Do B Adjust closer. Adjust closer. Add EXIT sign per requirements below. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3060 Exteri Dos A & B : RS7 : 1 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 11.30 Other If one of the exteri dos is used as a public entrance to the suite, install an ISA sign. See SF10 EN1, 10.2 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3200 : RS8 : 2 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3200 : RS8 : 2 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 15 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3200 : RS8 : 2 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 11.30 Other Closers on interi office and conference rooms vary between 16 18 lbs. No tactile characters. Not upper case. Signage does not meet current regulations. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. Adjust closers. NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3225 : RS9 : 2 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3225 : RS9 : 2 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 No closer. No closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3225 : RS9 : 2 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 No tactile characters. Not upper case. Signage does not meet current regulations. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other Interi dos not on closers and not surveyed. NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3250 : RS10 : 2 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3250 : RS10 : 2 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 22 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3250 : RS10 : 2 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 No tactile characters. Not upper case. Signage does not meet current regulations. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3320 Do A : RS11 : 3 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3320 Do A : RS11 : 3 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 20 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3320 Do A : RS11 : 3 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 No tactile characters. Signage does not meet current regulations. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3320 Do B : RS11 : 3 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3320 Do B : RS11 : 3 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 13 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3320 Do B : RS11 : 3 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Blank sign installed on side of do. See 11.21 above. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3330 : RS12 : 3 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3330 : RS12 : 3 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 >15 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3330 : RS12 : 3 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 No tactile characters. Not upper case. Signage does not meet current regulations. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3360 Do A : RS13 : 3 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3360 Do A : RS13 : 3 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 Do was not on a closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3360 Do A : RS13 : 3 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Technically the sign is located against the do jamb; however, there is not a swinging do at this location. No tactile characters. Not upper case. Signage does not meet current regulations. Provide EXIT ROUTE sign if required. Mount on sidewall adjacent to doway. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3360 Do B : RS13 : 3 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3360 Do B : RS13 : 3 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 20 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3360 Do B : RS13 : 3 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 See 11.21 above. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3360 Do C : RS13 : 3 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3360 Do C : RS13 : 3 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 19 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3360 Do C : RS13 : 3 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 See 11.21 above. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Interi suite not surveyed. Page 3 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3380 : RS14 : 3 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? 206.4 /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? 404.2.1, 404.3.7 /// 1133B.2.3.3; 1133B.2.3.4 11.4 Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B.1.1.1.4 11.5 Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? 404.2.3 /// 1133B.1.1.1.1, 1133B.2.2, 1133B.2.3.1 11.6 Do Maneuvering If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? 404.2.4.4 /// 1133B.2.4 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? 404.2.6 /// 1133B.2.4.4 Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? 404.2.6 /// 1133B.2.4.4 11.10 Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? 404.2.5 /// 1133B.2.4.1 Page 1 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3380 : RS14 : 3 : 11.11 Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) 404.2.7 /// 1133B.2.5.2 11.12 Hardware Is any operating hardware mounted between 30 and 44 above the flo? 404.2.7 /// 1133B.2.5.2 11.13 Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 11.14 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 11.15 Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? 404.2.10 /// 1133B.2.6 11.16 Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? 404.3 /// 1133B.2.3.2 11.17 Room/ Identification 11.18 Tactile Exit 11.19 Tactile Exit 11.20 Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? 216.2 /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 3 >20 lbs Adjust closer. Page 2 of 3

DOORS AND GATES Survey Fm 11 /Room 30 Liberty Ship Way Name: 3380 : RS14 : 3 : 11.21 Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? 216.4.1 /// 1011.3 item 4 11.22 Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B.5.7 11.23 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 11.24 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 11.25 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 11.26 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 11.27 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 11.28 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 11.29 Other Identification Signage Do the signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 No tactile characters. Not upper case. Signage does not meet current regulations. Provide EXIT ROUTE sign if required. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 11.30 Other NOTES: Interi suite not surveyed. Page 3 of 3

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B.1 16.2 Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? 213.2 /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? 213.2 /// 1115B.1.1 Is the toilet room located on an accessible route of travel? 206.2.4 /// 1115B.1 16.5 Entry Dos Does the do comply with the requirements below? 404 /// 1115B.5 16.6 Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? 404.2.3 /// 1133B.2.2 16.7 Do Swing Does the do swing not intrude into the clear flo space at any fixture? 404.2.3 /// 1115B.5 16.8 Do Maneuvering 16.9 Do Hardware 16.10 Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7 /// 1133B.2.5.2 Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 16.11 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 >15 lbs Adjust closer. Page 1 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : 16.12 Identification Symbols 16.13 Identification Symbols 16.14 Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? 216.2 /// 1117B.5.1 item 1 16.15 Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? 703.1 /// 1117B.5.1 item 2 16.16 Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? 703.6 /// 1117B.5.5 item 3 16.17 ISA If the toilet room is accessible, is the room identified by an ISA? 216.8 /// 1117B.5.1 item 3 16.18 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 16.19 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 16.20 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 16.21 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 16.22 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 61 Page 2 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : 16.23 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 16.24 Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 16.25 Surface Is the surface of the toilet room stable, firm, and slip resistant? 302.1 /// 1124B.1 16.26 Maneuvering 16.27 Maneuvering 16.28 Maneuvering 16.29 Stall Do Width 16.30 Stall Do Width 16.31 Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.). 603.2 /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than 12. 603.2.3 /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? 206.2.4 /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? 604.8.1.2 /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? 604.8.1.2 /// 1115B.3.1 item 4.5 16.32 Stall Do Is the stall do self-closing? 604.8.1.2 /// 1115B.3.1 item 4.4 16.33 Stall Do Strike Edge 16.34 Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? 604.8.1.2 /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? 604.8.1.2 /// 1115B.3.1 item 4.3 16.35 Stall Width Is the stall at least 60 wide? 604.8.1.1 /// 1115B.3.1 item 4.1 See approximate dimensions below. See approximate dimensions below. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 34-3/8 Hardware on pull side only. 58-3/4 Page 3 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : 16.36 Stall Maneuvering 16.37 Stall Maneuvering 16.38 Stall Maneuvering 16.39 Stall Do Location 16.40 Maneuvering 16.41 Maneuvering 16.42 WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? 604.8.1.1 /// 1115B.3.1 item 4.2 Stall width is 58-3/4. If the stall has an in-swinging side entry stall do, is Stall depth is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep not allow f the 86-3/4 which does space f flo-mounted WC? (Toilet compartment 56 minimum deep dos shall not swing into the minimum required space. See sketch compartment area.) below. 604.8.1.1, 604.8.1.2 /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? 604.8.1.2 /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A 16.43 WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? 604.2 /// 1115B.4.1 item 1 16.44 WC Seat Is the top of the WC seat between 17 and 19 AFF? 604.4 /// 1115B.4.1 item 4 16.45 WC Flush Controls 16.46 Toilet Paper Dispenser 16.47 Toilet Paper Dispenser Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? 604.6 /// 1115B.4.1 item 5 Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? 604.7 /// 1115B.8.4 **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. Is the toilet paper dispenser mounted below the side grab bar? 604.7 /// 1115B.8.4 33 18 19-3/8 37-1/2 from back wall. Bottom roll: 20-1/2 Top roll: 28-1/2 Dispenser needs to be mounted within 36 minimum from the rear wall a minimum of 7 and a maximum of 9 in front of the water closet per the new code. Page 4 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : 16.48 Toilet Paper Dispenser 16.49 Seat Cover Dispenser Does the toilet paper dispenser allow continuous paper delivery? 604.7 /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B.8.3 16.50 Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A 16.51 Grab Bar Diameter 16.52 Grab Bar Wall Clearance 16.53 Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? 609.2 /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? 609.3 /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? 609.3 /// 40 **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions. 16.54 Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? 609.5 /// 1115B.7.3 16.55 Side Grab Bar Does the side grab bar extend at least 54 min beyond the rear wall while the other end is a maximum of 12 from the rear wall, with the front end positioned 24 min. in front of the WC? 604.5.1 /// 1115B.4.1 item 3.1 16.56 Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? 604.5.2 /// 1115B.4.1 item 3.2 16.57 Semi- Ambulant Stall 16.58 Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? 604.8.2 /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? 604.8.2.3 /// 1115B.3.1 item 5, 1115B.4.1 item 3 16.59 Urinals Where urinals are provided, does at least one comply with the requirements below? 213.3.3 /// 1115B.4.2 52 from rear wall. Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Page 5 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : 16.60 Urinal Rim Height 16.61 Clear at Urinal 16.62 Width Between Screens at Urinal 16.63 Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? 605.2 /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, 305.7.1 /// 1118B.4 item 2, Fig. 11B-5A(b) 16.64 Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? 213.3.4 /// 1115B.4.3 16.65 Lavaty Rim Height 16.66 Lavaty Apron Clearance 16.67 Lavaty Knee Clearance 16.68 Lavaty Wall ion 16.69 Clear at Lavaty 16.70 Side Clearance at Lavaty 16.71 Lavaty Location 16.72 Pipe Insulation at Lavaty 16.73 Smooth Surfaces at Lavaty 16.74 Faucet Operation at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? 606.3 /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? 606.2 /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? 606.2 /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item 2 Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? 606.5 /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? 606.5 /// 1115B.4.3 item 4 Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? 606.4 /// 1115B.4.3 item 1 Left Side: 34 Right Side: 34-1/4 Page 6 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : 16.75 Faucet Operation at Lavaty If the valve is self-closing, does it remain open f at least 10 seconds? 606.4 /// 1115B.4.3 item 1 16.76 Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? 603.3 /// 1115B.8.1 16.77 Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? 604.8.3 /// 1117B.8 16.78 Dispensers Operating Height 16.79 at Dispensers 16.80 Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? 305.3 /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item 4 16.81 Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// 907.9.1, 907.9.2, 1114B.2.2 37-1/2 40 Paper towel: OK Sanitary Napkin Dispenser: OK. 16.82 Other slopes are good. NOTES: Typical 1 st Men s and Women s Restrooms. (Dimensions Approximate) Code Clearance Page 7 of 7

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Women s Shower 1 st TR1 : Shower : 1st : 17.1 17.2 17.3 17.4 17.5 17.6 17.7 17.8 17.9 17.10 17.11 17.12 17.13 17.14 30 x 60 Shower Stall Design 30 x 60 Shower Stall Design Alternate Roll-In Shower Stall Design Alternate Roll-In Shower Stall Design Design Design Seating Seating Seating Seating Seating Seating Seating Grab Bar Is the roll-in shower a minimum 60 in width between wall surfaces and a minimum 30 in depth with a full opening width on the long side. 608.2.2 /// 1115B.4.4.1.1 Is the clear flo space that adjoins the shower compartment a minimum of 36 x 60? 608.2.2 /// 1115B.4.4.1.1 Is the roll-in shower a minimum 36 x 60 with a minimum entry width of 36? 608.2.3 /// 1115B.4.4.1.2 Is there a minimum 36 wide clear flo space adjoining the shower seat to allow f parallel transfer? 608.2.3 /// 1115B.4.4.1.2 Is the surface slope at 2% less in any direction? 304.2 /// 1115B.4.4.7 Where drains are provided, are the grate openings minimum of ¼ and located flush with the flo surface? 302.3 ///1115B.4.4.7 Is there a folding seat mounted 18 above flo? Is the clearance from the seat to the adjacent wall surfaces minimum of 1 and a maximum of 1 ½? 608.4, 610.3 /// 1115B.4.4.8.1 When folded, does the shower seat extend a maximum 6 from the mounting (back) wall? ///1115B.4.4.8.1 Does the folding seat extend the full-required depth of the stall? 610.3 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 15 from the adjacent wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 23 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the narrow ption of the seat extend a maximum of 16 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the shower seat provide a minimum Structural strength to suppt a 250 lb point load? 610.4 /// 1115B.4.4.8.1, 1115B.7.2 Are grab bars located on walls adjacent to and opposite the seat? 608.3 /// 1115B.4.4.8.2, Fig. 11A, 11B As-built Dimensions 43-1/8 x 59-9/16 Entry width at 35-3/8 2.8% Seat mounted 3 off back wall. Height OK 5-1/2 16-3/8 22-1/2 16-1/2 Page 1 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Women s Shower 1 st TR1 : Shower : 1st : 17.15 17.16 17.17 17.18 17.19 17.20 17.21 17.22 17.23 17.24 17.25 17.26 17.27 17.28 Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Design Controls Controls Controls Controls Controls Controls Is grab bar L-shaped and continuous along the wall opposite from and adjacent to the seat? (But NOT extended to include the ption of wall over the seat) 608.3 /// 1115B.4.4.8.2 Are grab bars mounted between 33 36 above flo surface? 609.4 /// 1115B.4.4.8.2 Are grab bars between 1 ¼ 1 ½ diameter equivalent? 609.2 /// 1115B.7.1 Is the clearance between the wall and grab bar 1 ½? 609.3 /// 1115B.7.1 Are the bars smooth with a minimum radius of 1/8? 609.5 /// 1115B.4.1.3, 1115B.7.3 Do the bars provide a minimum structural strength to suppt a 250lb point load? 609.8 /// 1115B.7.1.2 thru.4 Are the grab bars stable and do not rotate within their fittings? 609.6 /// 1115B.7.2.5 Is the water valve control a single lever type? 608.5 /// 1115B.4.4.4 Is the centerline of the control located on the side wall of the compartment adjacent to the seat within reach range of no less than 19 and no me than 24 from the rear edge of the seat? 608.5.2, 608.5.3 /// 1115B.4.4.4.1 Is the fce to operate the controls a maximum of 5lbs? 309.4 /// 1115B.4.4.4 Is the centerline of the control valves between 39 to 41 above the shower flo? 608.5.2, 608.5.3 /// 1115B.4.4.4 Are the controls operable with one hand and do not require tight grasping, pinching twisting of the wrist? 309.4 /// 1115B.4.4.4 Is a flexible hand held spray unit with a hose at least 60 long that can be used both as a fixed shower head and as a hand-held shower provided and mounted such that the top of the mounting bracket is at a maximum height of 48 from the flo? 608.6 /// 1115B.4.4.5 Is the hand-held sprayer unit located on the back wall of the compartment adjacent to the seat, and the centerline of the control is no me than 27 from the seat wall? 608.5.2, 608.5.3 /// 1115B.4.4.5 As-built Dimensions 33 1-1/2 Control Valve at 23-1/2 Diverter Valve at 13-1/2 Diverter valve should be located with-in the control area of 19 24 from the rear edge of the seat. 40-1/4 43 High 9 from the wall. Page 2 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Women s Shower 1 st TR1 : Shower : 1st : 17.29 17.30 17.31 Design Design Is the soap dish mounted on the control wall at 40 maximum height and within reach limits from the seat? /// 1115B.4.4.9 Where lockers are provided f the public, clients, employees, members, participants, is at least one and not less than 5% of all lockers accessible. Is a path of travel not less than 36 in clear width provided to these lockers? As-built Dimensions No soap dish. 225.2.1 /// 1115B.8.5, 1115B.2 Other Hooks at 48 and 54 AFF Do not meet required reach ranges no higher than 48. Lower add hook at a height not greater than 48. NOTES: Page 3 of 3

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 1 st : TR2 : 1st : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B.1 16.2 Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? 213.2 /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? 213.2 /// 1115B.1.1 Is the toilet room located on an accessible route of travel? 206.2.4 /// 1115B.1 16.5 Entry Dos Does the do comply with the requirements below? 404 /// 1115B.5 16.6 Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? 404.2.3 /// 1133B.2.2 16.7 Do Swing Does the do swing not intrude into the clear flo space at any fixture? 404.2.3 /// 1115B.5 16.8 Do Maneuvering 16.9 Do Hardware 16.10 Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7 /// 1133B.2.5.2 Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 16.11 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 >15 lbs Adjust closer. Page 1 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 1 st : TR2 : 1st : 16.12 Identification Symbols 16.13 Identification Symbols 16.14 Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? 216.2 /// 1117B.5.1 item 1 16.15 Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? 703.1 /// 1117B.5.1 item 2 16.16 Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? 703.6 /// 1117B.5.5 item 3 16.17 ISA If the toilet room is accessible, is the room identified by an ISA? 216.8 /// 1117B.5.1 item 3 16.18 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 16.19 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 16.20 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 16.21 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 16.22 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 59-3/4 Page 2 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 1 st : TR2 : 1st : 16.23 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 16.24 Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 16.25 Surface Is the surface of the toilet room stable, firm, and slip resistant? 302.1 /// 1124B.1 16.26 Maneuvering 16.27 Maneuvering 16.28 Maneuvering 16.29 Stall Do Width 16.30 Stall Do Width 16.31 Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.). 603.2 /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than 12. 603.2.3 /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? 206.2.4 /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? 604.8.1.2 /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? 604.8.1.2 /// 1115B.3.1 item 4.5 16.32 Stall Do Is the stall do self-closing? 604.8.1.2 /// 1115B.3.1 item 4.4 16.33 Stall Do Strike Edge 16.34 Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? 604.8.1.2 /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? 604.8.1.2 /// 1115B.3.1 item 4.3 16.35 Stall Width Is the stall at least 60 wide? 604.8.1.1 /// 1115B.3.1 item 4.1 See approximate dimensions below. See approximate dimensions below. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 34-1/2 Hardware on pull side only. 58-3/4 Page 3 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 1 st : TR2 : 1st : 16.36 Stall Maneuvering 16.37 Stall Maneuvering 16.38 Stall Maneuvering 16.39 Stall Do Location 16.40 Maneuvering 16.41 Maneuvering 16.42 WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? 604.8.1.1 /// 1115B.3.1 item 4.2 Stall width is 58-3/4. If the stall has an in-swinging side entry stall do, is Stall depth is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep not allow f the 87-1/8 which does space f flo-mounted WC? (Toilet compartment 56 minimum deep dos shall not swing into the minimum required space. See sketch compartment area.) below. 604.8.1.1, 604.8.1.2 /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? 604.8.1.2 /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A 16.43 WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? 604.2 /// 1115B.4.1 item 1 16.44 WC Seat Is the top of the WC seat between 17 and 19 AFF? 604.4 /// 1115B.4.1 item 4 16.45 WC Flush Controls 16.46 Toilet Paper Dispenser 16.47 Toilet Paper Dispenser Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? 604.6 /// 1115B.4.1 item 5 Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? 604.7 /// 1115B.8.4 **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. Is the toilet paper dispenser mounted below the side grab bar? 604.7 /// 1115B.8.4 32-1/2 17-1/2 19-1/4 36-1/2 from back wall. Bottom roll: 20-1/2 Top roll: 28-1/2 Dispenser needs to be mounted within 36 minimum from the rear wall a minimum of 7 and a maximum of 9 in front of the water closet per the new code. Page 4 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 1 st : TR2 : 1st : 16.48 Toilet Paper Dispenser 16.49 Seat Cover Dispenser Does the toilet paper dispenser allow continuous paper delivery? 604.7 /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B.8.3 16.50 Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A 16.51 Grab Bar Diameter 16.52 Grab Bar Wall Clearance 16.53 Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? 609.2 /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? 609.3 /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? 609.3 /// 40 **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions. 16.54 Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? 609.5 /// 1115B.7.3 16.55 Side Grab Bar Does the side grab bar extend at least 54 min beyond the rear wall while the other end is a maximum of 12 from the rear wall, with the front end positioned 24 min. in front of the WC? 604.5.1 /// 1115B.4.1 item 3.1 16.56 Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? 604.5.2 /// 1115B.4.1 item 3.2 16.57 Semi- Ambulant Stall 16.58 Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? 604.8.2 /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? 604.8.2.3 /// 1115B.3.1 item 5, 1115B.4.1 item 3 16.59 Urinals Where urinals are provided, does at least one comply with the requirements below? 213.3.3 /// 1115B.4.2 48 from rear wall. Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Page 5 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 1 st : TR2 : 1st : 16.60 Urinal Rim Height 16.61 Clear at Urinal 16.62 Width Between Screens at Urinal 16.63 Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? 605.2 /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, 305.7.1 /// 1118B.4 item 2, Fig. 11B-5A(b) 16.64 Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? 213.3.4 /// 1115B.4.3 16.65 Lavaty Rim Height 16.66 Lavaty Apron Clearance 16.67 Lavaty Knee Clearance 16.68 Lavaty Wall ion 16.69 Clear at Lavaty 16.70 Side Clearance at Lavaty 16.71 Lavaty Location 16.72 Pipe Insulation at Lavaty 16.73 Smooth Surfaces at Lavaty 16.74 Faucet Operation at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? 606.3 /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? 606.2 /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? 606.2 /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item 2 Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? 606.5 /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? 606.5 /// 1115B.4.3 item 4 Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? 606.4 /// 1115B.4.3 item 1 36-1/4 Left Side: 34-1/4 Right Side: 34 Page 6 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 1 st : TR2 : 1st : 16.75 Faucet Operation at Lavaty If the valve is self-closing, does it remain open f at least 10 seconds? 606.4 /// 1115B.4.3 item 1 16.76 Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? 603.3 /// 1115B.8.1 16.77 Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? 604.8.3 /// 1117B.8 16.78 Dispensers Operating Height 16.79 at Dispensers 16.80 Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? 305.3 /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item 4 16.81 Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// 907.9.1, 907.9.2, 1114B.2.2 37-1/2 40-1/4 Paper towel: OK. 16.82 Other slopes are good. NOTES: Typical 1 st Men s and Women s Restrooms. (Dimensions Approximate) Code Clearance Page 7 of 7

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Men s Shower 1 st TR2 : Shower : 1st : 17.1 17.2 17.3 17.4 17.5 17.6 17.7 17.8 17.9 17.10 17.11 17.12 17.13 17.14 30 x 60 Shower Stall Design 30 x 60 Shower Stall Design Alternate Roll-In Shower Stall Design Alternate Roll-In Shower Stall Design Design Design Seating Seating Seating Seating Seating Seating Seating Grab Bar Is the roll-in shower a minimum 60 in width between wall surfaces and a minimum 30 in depth with a full opening width on the long side. 608.2.2 /// 1115B.4.4.1.1 Is the clear flo space that adjoins the shower compartment a minimum of 36 x 60? 608.2.2 /// 1115B.4.4.1.1 Is the roll-in shower a minimum 36 x 60 with a minimum entry width of 36? 608.2.3 /// 1115B.4.4.1.2 Is there a minimum 36 wide clear flo space adjoining the shower seat to allow f parallel transfer? 608.2.3 /// 1115B.4.4.1.2 Is the surface slope at 2% less in any direction? 304.2 /// 1115B.4.4.7 Where drains are provided, are the grate openings minimum of ¼ and located flush with the flo surface? 302.3 ///1115B.4.4.7 Is there a folding seat mounted 18 above flo? Is the clearance from the seat to the adjacent wall surfaces minimum of 1 and a maximum of 1 ½? 608.4, 610.3 /// 1115B.4.4.8.1 When folded, does the shower seat extend a maximum 6 from the mounting (back) wall? ///1115B.4.4.8.1 Does the folding seat extend the full-required depth of the stall? 610.3 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 15 from the adjacent wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 23 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the narrow ption of the seat extend a maximum of 16 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the shower seat provide a minimum Structural strength to suppt a 250 lb point load? 610.4 /// 1115B.4.4.8.1, 1115B.7.2 Are grab bars located on walls adjacent to and opposite the seat? 608.3 /// 1115B.4.4.8.2, Fig. 11A, 11B As-built Dimensions 42-5/8 x 59-5/16 Entry width at 35-5/16 3.5% Seat mounted 3 off back wall. Height 18-1/2 at front of seat due to flo slope. 5-1/2 16-3/8 (seat mounted 3 off back wall) 22-3/8 15-3/4 Page 1 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Men s Shower 1 st TR2 : Shower : 1st : 17.15 17.16 17.17 17.18 17.19 17.20 17.21 17.22 17.23 17.24 17.25 17.26 17.27 17.28 Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Design Controls Controls Controls Controls Controls Controls Is grab bar L-shaped and continuous along the wall opposite from and adjacent to the seat? (But NOT extended to include the ption of wall over the seat) 608.3 /// 1115B.4.4.8.2 Are grab bars mounted between 33 36 above flo surface? 609.4 /// 1115B.4.4.8.2 Are grab bars between 1 ¼ 1 ½ diameter equivalent? 609.2 /// 1115B.7.1 Is the clearance between the wall and grab bar 1 ½? 609.3 /// 1115B.7.1 Are the bars smooth with a minimum radius of 1/8? 609.5 /// 1115B.4.1.3, 1115B.7.3 Do the bars provide a minimum structural strength to suppt a 250lb point load? 609.8 /// 1115B.7.1.2 thru.4 Are the grab bars stable and do not rotate within their fittings? 609.6 /// 1115B.7.2.5 Is the water valve control a single lever type? 608.5 /// 1115B.4.4.4 Is the centerline of the control located on the side wall of the compartment adjacent to the seat within reach range of no less than 19 and no me than 24 from the rear edge of the seat? 608.5.2, 608.5.3 /// 1115B.4.4.4.1 Is the fce to operate the controls a maximum of 5lbs? 309.4 /// 1115B.4.4.4 Is the centerline of the control valves between 39 to 41 above the shower flo? 608.5.2, 608.5.3 /// 1115B.4.4.4 Are the controls operable with one hand and do not require tight grasping, pinching twisting of the wrist? 309.4 /// 1115B.4.4.4 Is a flexible hand held spray unit with a hose at least 60 long that can be used both as a fixed shower head and as a hand-held shower provided and mounted such that the top of the mounting bracket is at a maximum height of 48 from the flo? 608.6 /// 1115B.4.4.5 Is the hand-held sprayer unit located on the back wall of the compartment adjacent to the seat, and the centerline of the control is no me than 27 from the seat wall? 608.5.2, 608.5.3 /// 1115B.4.4.5 As-built Dimensions 33 1-1/2 Control Valve at 23-1/4 Diverter Valve at 13 Diverter valve should be located with-in the control area of 19 24 from the rear edge of the seat. 40 44 High 9 from the wall. Page 2 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Men s Shower 1 st TR2 : Shower : 1st : 17.29 17.30 17.31 Design Design Is the soap dish mounted on the control wall at 40 maximum height and within reach limits from the seat? /// 1115B.4.4.9 Where lockers are provided f the public, clients, employees, members, participants, is at least one and not less than 5% of all lockers accessible. Is a path of travel not less than 36 in clear width provided to these lockers? As-built Dimensions No soap dish. 225.2.1 /// 1115B.8.5, 1115B.2 Other Hooks at 48 and 54 AFF Do not meet required reach ranges no higher than 48. Lower add hook at a height not greater than 48. NOTES: Page 3 of 3

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B.1 16.2 Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? 213.2 /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? 213.2 /// 1115B.1.1 Is the toilet room located on an accessible route of travel? 206.2.4 /// 1115B.1 16.5 Entry Dos Does the do comply with the requirements below? 404 /// 1115B.5 16.6 Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? 404.2.3 /// 1133B.2.2 16.7 Do Swing Does the do swing not intrude into the clear flo space at any fixture? 404.2.3 /// 1115B.5 16.8 Do Maneuvering 16.9 Do Hardware 16.10 Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7 /// 1133B.2.5.2 Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 16.11 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 >20 lbs Adjust closer. Page 1 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : 16.12 Identification Symbols 16.13 Identification Symbols 16.14 Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? 216.2 /// 1117B.5.1 item 1 16.15 Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? 703.1 /// 1117B.5.1 item 2 16.16 Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? 703.6 /// 1117B.5.5 item 3 16.17 ISA If the toilet room is accessible, is the room identified by an ISA? 216.8 /// 1117B.5.1 item 3 16.18 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 16.19 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 16.20 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 16.21 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 16.22 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 59 Page 2 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : 16.23 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 16.24 Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 16.25 Surface Is the surface of the toilet room stable, firm, and slip resistant? 302.1 /// 1124B.1 16.26 Maneuvering 16.27 Maneuvering 16.28 Maneuvering 16.29 Stall Do Width 16.30 Stall Do Width 16.31 Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.). 603.2 /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than 12. 603.2.3 /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? 206.2.4 /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? 604.8.1.2 /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? 604.8.1.2 /// 1115B.3.1 item 4.5 16.32 Stall Do Is the stall do self-closing? 604.8.1.2 /// 1115B.3.1 item 4.4 16.33 Stall Do Strike Edge 16.34 Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? 604.8.1.2 /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? 604.8.1.2 /// 1115B.3.1 item 4.3 16.35 Stall Width Is the stall at least 60 wide? 604.8.1.1 /// 1115B.3.1 item 4.1 See approximate dimensions below. See approximate dimensions below. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 34-1/2 Hardware on pull side only. 58-3/4 Page 3 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : 16.36 Stall Maneuvering 16.37 Stall Maneuvering 16.38 Stall Maneuvering 16.39 Stall Do Location 16.40 Maneuvering 16.41 Maneuvering 16.42 WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? 604.8.1.1 /// 1115B.3.1 item 4.2 Stall width is 58-3/4. If the stall has an in-swinging side entry stall do, is Stall depth is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep not allow f the 85-3/4 which does space f flo-mounted WC? (Toilet compartment 56 minimum deep dos shall not swing into the minimum required space. See sketch compartment area.) below. 604.8.1.1, 604.8.1.2 /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? 604.8.1.2 /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A 16.43 WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? 604.2 /// 1115B.4.1 item 1 16.44 WC Seat Is the top of the WC seat between 17 and 19 AFF? 604.4 /// 1115B.4.1 item 4 16.45 WC Flush Controls 16.46 Toilet Paper Dispenser 16.47 Toilet Paper Dispenser Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? 604.6 /// 1115B.4.1 item 5 Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? 604.7 /// 1115B.8.4 **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. Is the toilet paper dispenser mounted below the side grab bar? 604.7 /// 1115B.8.4 33 17-1/2 18-1/2 37 from back wall. Bottom roll: 20 Top roll: 28 Dispenser needs to be mounted within 36 minimum from the rear wall a minimum of 7 and a maximum of 9 in front of the water closet per the new code. Page 4 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : 16.48 Toilet Paper Dispenser 16.49 Seat Cover Dispenser Does the toilet paper dispenser allow continuous paper delivery? 604.7 /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B.8.3 16.50 Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A 16.51 Grab Bar Diameter 16.52 Grab Bar Wall Clearance 16.53 Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? 609.2 /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? 609.3 /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? 609.3 /// 40 **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions. 16.54 Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? 609.5 /// 1115B.7.3 16.55 Side Grab Bar Does the side grab bar extend at least 54 min beyond the rear wall while the other end is a maximum of 12 from the rear wall, with the front end positioned 24 min. in front of the WC? 604.5.1 /// 1115B.4.1 item 3.1 16.56 Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? 604.5.2 /// 1115B.4.1 item 3.2 16.57 Semi- Ambulant Stall 16.58 Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? 604.8.2 /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? 604.8.2.3 /// 1115B.3.1 item 5, 1115B.4.1 item 3 16.59 Urinals Where urinals are provided, does at least one comply with the requirements below? 213.3.3 /// 1115B.4.2 51 from rear wall. Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Men s and Women s restroom swapped on 2 nd Page 5 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : 16.60 Urinal Rim Height 16.61 Clear at Urinal 16.62 Width Between Screens at Urinal 16.63 Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? 605.2 /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, 305.7.1 /// 1118B.4 item 2, Fig. 11B-5A(b) 16.64 Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? 213.3.4 /// 1115B.4.3 16.65 Lavaty Rim Height 16.66 Lavaty Apron Clearance 16.67 Lavaty Knee Clearance 16.68 Lavaty Wall ion 16.69 Clear at Lavaty 16.70 Side Clearance at Lavaty 16.71 Lavaty Location 16.72 Pipe Insulation at Lavaty 16.73 Smooth Surfaces at Lavaty 16.74 Faucet Operation at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? 606.3 /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? 606.2 /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? 606.2 /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item 2 Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? 606.5 /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? 606.5 /// 1115B.4.3 item 4 Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? 606.4 /// 1115B.4.3 item 1 Men s and Women s restroom swapped on 2 nd 36 Left Side: 34-1/8 Right Side: 34 Page 6 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : 16.75 Faucet Operation at Lavaty If the valve is self-closing, does it remain open f at least 10 seconds? 606.4 /// 1115B.4.3 item 1 16.76 Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? 603.3 /// 1115B.8.1 16.77 Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? 604.8.3 /// 1117B.8 16.78 Dispensers Operating Height 16.79 at Dispensers 16.80 Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? 305.3 /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item 4 16.81 Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// 907.9.1, 907.9.2, 1114B.2.2 37-1/2 40 Paper towel: OK. 16.82 Other slope good. NOTES: Typical 2nd Men s and Women s Restrooms. (Dimensions Approximate) Code Clearance Page 7 of 7

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Women s Shower 2nd TR3 : Shower : 2nd : 17.1 17.2 17.3 17.4 17.5 17.6 17.7 17.8 17.9 17.10 17.11 17.12 17.13 17.14 30 x 60 Shower Stall Design 30 x 60 Shower Stall Design Alternate Roll-In Shower Stall Design Alternate Roll-In Shower Stall Design Design Design Seating Seating Seating Seating Seating Seating Seating Grab Bar Is the roll-in shower a minimum 60 in width between wall surfaces and a minimum 30 in depth with a full opening width on the long side. 608.2.2 /// 1115B.4.4.1.1 Is the clear flo space that adjoins the shower compartment a minimum of 36 x 60? 608.2.2 /// 1115B.4.4.1.1 Is the roll-in shower a minimum 36 x 60 with a minimum entry width of 36? 608.2.3 /// 1115B.4.4.1.2 Is there a minimum 36 wide clear flo space adjoining the shower seat to allow f parallel transfer? 608.2.3 /// 1115B.4.4.1.2 Is the surface slope at 2% less in any direction? 304.2 /// 1115B.4.4.7 Where drains are provided, are the grate openings minimum of ¼ and located flush with the flo surface? 302.3 ///1115B.4.4.7 Is there a folding seat mounted 18 above flo? Is the clearance from the seat to the adjacent wall surfaces minimum of 1 and a maximum of 1 ½? 608.4, 610.3 /// 1115B.4.4.8.1 When folded, does the shower seat extend a maximum 6 from the mounting (back) wall? ///1115B.4.4.8.1 Does the folding seat extend the full-required depth of the stall? 610.3 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 15 from the adjacent wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 23 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the narrow ption of the seat extend a maximum of 16 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the shower seat provide a minimum Structural strength to suppt a 250 lb point load? 610.4 /// 1115B.4.4.8.1, 1115B.7.2 Are grab bars located on walls adjacent to and opposite the seat? 608.3 /// 1115B.4.4.8.2, Fig. 11A, 11B As-built Dimensions 43 x 65-5/8 Entry width at 35-5/8 2.3% thru 3.5% Seat mounted 3 off back wall. Height 18-1/2 at front of seat due to flo slope. 5-1/2 16-3/8 (seat mounted 3 off back wall) 22-3/8 15-7/8 Page 1 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Women s Shower 2nd TR3 : Shower : 2nd : 17.15 17.16 17.17 17.18 17.19 17.20 17.21 17.22 17.23 17.24 17.25 17.26 17.27 17.28 Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Design Controls Controls Controls Controls Controls Controls Is grab bar L-shaped and continuous along the wall opposite from and adjacent to the seat? (But NOT extended to include the ption of wall over the seat) 608.3 /// 1115B.4.4.8.2 Are grab bars mounted between 33 36 above flo surface? 609.4 /// 1115B.4.4.8.2 Are grab bars between 1 ¼ 1 ½ diameter equivalent? 609.2 /// 1115B.7.1 Is the clearance between the wall and grab bar 1 ½? 609.3 /// 1115B.7.1 Are the bars smooth with a minimum radius of 1/8? 609.5 /// 1115B.4.1.3, 1115B.7.3 Do the bars provide a minimum structural strength to suppt a 250lb point load? 609.8 /// 1115B.7.1.2 thru.4 Are the grab bars stable and do not rotate within their fittings? 609.6 /// 1115B.7.2.5 Is the water valve control a single lever type? 608.5 /// 1115B.4.4.4 Is the centerline of the control located on the side wall of the compartment adjacent to the seat within reach range of no less than 19 and no me than 24 from the rear edge of the seat? 608.5.2, 608.5.3 /// 1115B.4.4.4.1 Is the fce to operate the controls a maximum of 5lbs? 309.4 /// 1115B.4.4.4 Is the centerline of the control valves between 39 to 41 above the shower flo? 608.5.2, 608.5.3 /// 1115B.4.4.4 Are the controls operable with one hand and do not require tight grasping, pinching twisting of the wrist? 309.4 /// 1115B.4.4.4 Is a flexible hand held spray unit with a hose at least 60 long that can be used both as a fixed shower head and as a hand-held shower provided and mounted such that the top of the mounting bracket is at a maximum height of 48 from the flo? 608.6 /// 1115B.4.4.5 Is the hand-held sprayer unit located on the back wall of the compartment adjacent to the seat, and the centerline of the control is no me than 27 from the seat wall? 608.5.2, 608.5.3 /// 1115B.4.4.5 As-built Dimensions 33 1-1/2 Control Valve at 21-3/4 Diverter Valve at 11-5/8 Diverter valve should be located with-in the control area of 19 24 from the rear edge of the seat. 39-3/8 43 High 8 from the wall. Page 2 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Women s Shower 2nd TR3 : Shower : 2nd : 17.29 17.30 17.31 Design Design Is the soap dish mounted on the control wall at 40 maximum height and within reach limits from the seat? /// 1115B.4.4.9 Where lockers are provided f the public, clients, employees, members, participants, is at least one and not less than 5% of all lockers accessible. Is a path of travel not less than 36 in clear width provided to these lockers? As-built Dimensions No soap dish. 225.2.1 /// 1115B.8.5, 1115B.2 Other Hooks at 48 and 54 AFF Do not meet required reach ranges no higher than 48. Lower add hook at a height not greater than 48. NOTES: Page 3 of 3

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B.1 16.2 Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? 213.2 /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? 213.2 /// 1115B.1.1 Is the toilet room located on an accessible route of travel? 206.2.4 /// 1115B.1 16.5 Entry Dos Does the do comply with the requirements below? 404 /// 1115B.5 16.6 Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? 404.2.3 /// 1133B.2.2 16.7 Do Swing Does the do swing not intrude into the clear flo space at any fixture? 404.2.3 /// 1115B.5 16.8 Do Maneuvering 16.9 Do Hardware 16.10 Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7 /// 1133B.2.5.2 Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 16.11 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 >15 lbs Adjust closer. Page 1 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : 16.12 Identification Symbols 16.13 Identification Symbols 16.14 Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? 216.2 /// 1117B.5.1 item 1 16.15 Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? 703.1 /// 1117B.5.1 item 2 16.16 Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? 703.6 /// 1117B.5.5 item 3 16.17 ISA If the toilet room is accessible, is the room identified by an ISA? 216.8 /// 1117B.5.1 item 3 16.18 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 16.19 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 16.20 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 16.21 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 16.22 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 58-3/4 Page 2 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : 16.23 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 16.24 Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 16.25 Surface Is the surface of the toilet room stable, firm, and slip resistant? 302.1 /// 1124B.1 16.26 Maneuvering 16.27 Maneuvering 16.28 Maneuvering 16.29 Stall Do Width 16.30 Stall Do Width 16.31 Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.). 603.2 /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than 12. 603.2.3 /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? 206.2.4 /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? 604.8.1.2 /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? 604.8.1.2 /// 1115B.3.1 item 4.5 16.32 Stall Do Is the stall do self-closing? 604.8.1.2 /// 1115B.3.1 item 4.4 16.33 Stall Do Strike Edge 16.34 Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? 604.8.1.2 /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? 604.8.1.2 /// 1115B.3.1 item 4.3 16.35 Stall Width Is the stall at least 60 wide? 604.8.1.1 /// 1115B.3.1 item 4.1 See approximate dimensions below. See approximate dimensions below. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 34-1/2 Hardware on pull side only. 58-1/4 Page 3 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : 16.36 Stall Maneuvering 16.37 Stall Maneuvering 16.38 Stall Maneuvering 16.39 Stall Do Location 16.40 Maneuvering 16.41 Maneuvering 16.42 WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? 604.8.1.1 /// 1115B.3.1 item 4.2 Stall width is 58-1/4. If the stall has an in-swinging side entry stall do, is Stall depth is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep allow f the 56 86 which does not space f flo-mounted WC? (Toilet compartment minimum deep dos shall not swing into the minimum required space. See sketch compartment area.) below. 604.8.1.1, 604.8.1.2 /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? 604.8.1.2 /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A 16.43 WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? 604.2 /// 1115B.4.1 item 1 16.44 WC Seat Is the top of the WC seat between 17 and 19 AFF? 604.4 /// 1115B.4.1 item 4 16.45 WC Flush Controls 16.46 Toilet Paper Dispenser 16.47 Toilet Paper Dispenser Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? 604.6 /// 1115B.4.1 item 5 Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? 604.7 /// 1115B.8.4 **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. Is the toilet paper dispenser mounted below the side grab bar? 604.7 /// 1115B.8.4 33 17-3/8 18-1/4 37-1/4 from back wall. Bottom roll: 20 Top roll: 28 Dispenser needs to be mounted within 36 minimum from the rear wall a minimum of 7 and a maximum of 9 in front of the water closet per the new code. Page 4 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : 16.48 Toilet Paper Dispenser 16.49 Seat Cover Dispenser Does the toilet paper dispenser allow continuous paper delivery? 604.7 /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B.8.3 16.50 Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A 16.51 Grab Bar Diameter 16.52 Grab Bar Wall Clearance 16.53 Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? 609.2 /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? 609.3 /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? 609.3 /// 40 **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions. 16.54 Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? 609.5 /// 1115B.7.3 16.55 Side Grab Bar Does the side grab bar extend at least 54 min beyond the rear wall while the other end is a maximum of 12 from the rear wall, with the front end positioned 24 min. in front of the WC? 604.5.1 /// 1115B.4.1 item 3.1 16.56 Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? 604.5.2 /// 1115B.4.1 item 3.2 16.57 Semi- Ambulant Stall 16.58 Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? 604.8.2 /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? 604.8.2.3 /// 1115B.3.1 item 5, 1115B.4.1 item 3 16.59 Urinals Where urinals are provided, does at least one comply with the requirements below? 213.3.3 /// 1115B.4.2 52 from rear wall. Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Men s and Women s restroom swapped on 2 nd Page 5 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : 16.60 Urinal Rim Height 16.61 Clear at Urinal 16.62 Width Between Screens at Urinal 16.63 Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? 605.2 /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, 305.7.1 /// 1118B.4 item 2, Fig. 11B-5A(b) 16.64 Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? 213.3.4 /// 1115B.4.3 16.65 Lavaty Rim Height 16.66 Lavaty Apron Clearance 16.67 Lavaty Knee Clearance 16.68 Lavaty Wall ion 16.69 Clear at Lavaty 16.70 Side Clearance at Lavaty 16.71 Lavaty Location 16.72 Pipe Insulation at Lavaty 16.73 Smooth Surfaces at Lavaty 16.74 Faucet Operation at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? 606.3 /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? 606.2 /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? 606.2 /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item 2 Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? 606.5 /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? 606.5 /// 1115B.4.3 item 4 Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? 606.4 /// 1115B.4.3 item 1 Men s and Women s restroom swapped on 2 nd Left Side: 34 Right Side: 34-1/8 Page 6 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : 16.75 Faucet Operation at Lavaty If the valve is self-closing, does it remain open f at least 10 seconds? 606.4 /// 1115B.4.3 item 1 16.76 Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? 603.3 /// 1115B.8.1 16.77 Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? 604.8.3 /// 1117B.8 16.78 Dispensers Operating Height 16.79 at Dispensers 16.80 Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? 305.3 /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item 4 16.81 Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// 907.9.1, 907.9.2, 1114B.2.2 37-1/2 40 Paper towel: OK Sanitary Napkin Dispenser: OK. 16.82 Other Slope to drain 2.8% NOTES: Typical 2nd Men s and Women s Restrooms. (Dimensions Approximate) Code Clearance Page 7 of 7

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Men s Shower 2nd TR4 : Shower : 2nd : 17.1 17.2 17.3 17.4 17.5 17.6 17.7 17.8 17.9 17.10 17.11 17.12 17.13 17.14 30 x 60 Shower Stall Design 30 x 60 Shower Stall Design Alternate Roll-In Shower Stall Design Alternate Roll-In Shower Stall Design Design Design Seating Seating Seating Seating Seating Seating Seating Grab Bar Is the roll-in shower a minimum 60 in width between wall surfaces and a minimum 30 in depth with a full opening width on the long side. 608.2.2 /// 1115B.4.4.1.1 Is the clear flo space that adjoins the shower compartment a minimum of 36 x 60? 608.2.2 /// 1115B.4.4.1.1 Is the roll-in shower a minimum 36 x 60 with a minimum entry width of 36? 608.2.3 /// 1115B.4.4.1.2 Is there a minimum 36 wide clear flo space adjoining the shower seat to allow f parallel transfer? 608.2.3 /// 1115B.4.4.1.2 Is the surface slope at 2% less in any direction? 304.2 /// 1115B.4.4.7 Where drains are provided, are the grate openings minimum of ¼ and located flush with the flo surface? 302.3 ///1115B.4.4.7 Is there a folding seat mounted 18 above flo? Is the clearance from the seat to the adjacent wall surfaces minimum of 1 and a maximum of 1 ½? 608.4, 610.3 /// 1115B.4.4.8.1 When folded, does the shower seat extend a maximum 6 from the mounting (back) wall? ///1115B.4.4.8.1 Does the folding seat extend the full-required depth of the stall? 610.3 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 15 from the adjacent wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 23 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the narrow ption of the seat extend a maximum of 16 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the shower seat provide a minimum Structural strength to suppt a 250 lb point load? 610.4 /// 1115B.4.4.8.1, 1115B.7.2 Are grab bars located on walls adjacent to and opposite the seat? 608.3 /// 1115B.4.4.8.2, Fig. 11A, 11B As-built Dimensions 32-3/4 x 59-1/2 29-3/8 x 59-1/2 No shower seat. 3.9% No shower seat. No grab bars. Page 1 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Men s Shower 2nd TR4 : Shower : 2nd : 17.15 17.16 17.17 17.18 17.19 17.20 17.21 17.22 17.23 17.24 17.25 17.26 17.27 17.28 Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Design Controls Controls Controls Controls Controls Controls Is grab bar L-shaped and continuous along the wall opposite from and adjacent to the seat? (But NOT extended to include the ption of wall over the seat) 608.3 /// 1115B.4.4.8.2 Are grab bars mounted between 33 36 above flo surface? 609.4 /// 1115B.4.4.8.2 Are grab bars between 1 ¼ 1 ½ diameter equivalent? 609.2 /// 1115B.7.1 Is the clearance between the wall and grab bar 1 ½? 609.3 /// 1115B.7.1 Are the bars smooth with a minimum radius of 1/8? 609.5 /// 1115B.4.1.3, 1115B.7.3 Do the bars provide a minimum structural strength to suppt a 250lb point load? 609.8 /// 1115B.7.1.2 thru.4 Are the grab bars stable and do not rotate within their fittings? 609.6 /// 1115B.7.2.5 Is the water valve control a single lever type? 608.5 /// 1115B.4.4.4 Is the centerline of the control located on the side wall of the compartment adjacent to the seat within reach range of no less than 19 and no me than 24 from the rear edge of the seat? 608.5.2, 608.5.3 /// 1115B.4.4.4.1 Is the fce to operate the controls a maximum of 5lbs? 309.4 /// 1115B.4.4.4 Is the centerline of the control valves between 39 to 41 above the shower flo? 608.5.2, 608.5.3 /// 1115B.4.4.4 Are the controls operable with one hand and do not require tight grasping, pinching twisting of the wrist? 309.4 /// 1115B.4.4.4 Is a flexible hand held spray unit with a hose at least 60 long that can be used both as a fixed shower head and as a hand-held shower provided and mounted such that the top of the mounting bracket is at a maximum height of 48 from the flo? 608.6 /// 1115B.4.4.5 Is the hand-held sprayer unit located on the back wall of the compartment adjacent to the seat, and the centerline of the control is no me than 27 from the seat wall? 608.5.2, 608.5.3 /// 1115B.4.4.5 As-built Dimensions No grab bars. Control Valve at 22-1/2 Diverter Valve at 12-1/4 Diverter valve should be located with-in the control area of 19 24 from the rear edge of the seat. 40-1/4 No shower seat. Page 2 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Men s Shower 2nd TR4 : Shower : 2nd : 17.29 17.30 17.31 Design Design Is the soap dish mounted on the control wall at 40 maximum height and within reach limits from the seat? /// 1115B.4.4.9 Where lockers are provided f the public, clients, employees, members, participants, is at least one and not less than 5% of all lockers accessible. Is a path of travel not less than 36 in clear width provided to these lockers? 225.2.1 /// 1115B.8.5, 1115B.2 As-built Dimensions No soap dish. Access to locker room 29-3/8. Other Hook to be provided no higher than 48. NOTES: Page 3 of 3

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 3rd : TR5 : 3rd : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B.1 16.2 Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? 213.2 /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? 213.2 /// 1115B.1.1 Is the toilet room located on an accessible route of travel? 206.2.4 /// 1115B.1 16.5 Entry Dos Does the do comply with the requirements below? 404 /// 1115B.5 16.6 Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? 404.2.3 /// 1133B.2.2 16.7 Do Swing Does the do swing not intrude into the clear flo space at any fixture? 404.2.3 /// 1115B.5 16.8 Do Maneuvering 16.9 Do Hardware 16.10 Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7 /// 1133B.2.5.2 Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 16.11 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 >18 lbs Adjust closer. Page 1 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 3rd : TR5 : 3rd : 16.12 Identification Symbols 16.13 Identification Symbols 16.14 Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? 216.2 /// 1117B.5.1 item 1 16.15 Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? 703.1 /// 1117B.5.1 item 2 16.16 Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? 703.6 /// 1117B.5.5 item 3 16.17 ISA If the toilet room is accessible, is the room identified by an ISA? 216.8 /// 1117B.5.1 item 3 16.18 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 16.19 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 16.20 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 16.21 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 16.22 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 60-1/2 Page 2 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 3rd : TR5 : 3rd : 16.23 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 16.24 Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 16.25 Surface Is the surface of the toilet room stable, firm, and slip resistant? 302.1 /// 1124B.1 16.26 Maneuvering 16.27 Maneuvering 16.28 Maneuvering 16.29 Stall Do Width 16.30 Stall Do Width 16.31 Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.). 603.2 /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than 12. 603.2.3 /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? 206.2.4 /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? 604.8.1.2 /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? 604.8.1.2 /// 1115B.3.1 item 4.5 16.32 Stall Do Is the stall do self-closing? 604.8.1.2 /// 1115B.3.1 item 4.4 16.33 Stall Do Strike Edge 16.34 Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? 604.8.1.2 /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? 604.8.1.2 /// 1115B.3.1 item 4.3 16.35 Stall Width Is the stall at least 60 wide? 604.8.1.1 /// 1115B.3.1 item 4.1 See approximate dimensions below. See approximate dimensions below. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 34-1/2 Hardware on pull side only. 59-3/16 Page 3 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 3rd : TR5 : 3rd : 16.36 Stall Maneuvering 16.37 Stall Maneuvering 16.38 Stall Maneuvering 16.39 Stall Do Location 16.40 Maneuvering 16.41 Maneuvering 16.42 WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? 604.8.1.1 /// 1115B.3.1 item 4.2 Stall width is 59-3/16. If the stall has an in-swinging side entry stall do, is Stall depth is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep does not allow f 86-7/16 which space f flo-mounted WC? (Toilet compartment the 56 minimum dos shall not swing into the minimum required deep space. See compartment area.) sketch below. 604.8.1.1, 604.8.1.2 /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? 604.8.1.2 /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A 16.43 WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? 604.2 /// 1115B.4.1 item 1 16.44 WC Seat Is the top of the WC seat between 17 and 19 AFF? 604.4 /// 1115B.4.1 item 4 16.45 WC Flush Controls 16.46 Toilet Paper Dispenser 16.47 Toilet Paper Dispenser Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? 604.6 /// 1115B.4.1 item 5 Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? 604.7 /// 1115B.8.4 **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. Is the toilet paper dispenser mounted below the side grab bar? 604.7 /// 1115B.8.4 32 18-1/2 at front 19 at back 37-1/2 from back wall. Bottom roll: 19-1/2 Top roll: 27-1/2 Dispenser needs to be mounted within 36 minimum from the rear wall a minimum of 7 and a maximum of 9 in front of the water closet per the new code. Page 4 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 3rd : TR5 : 3rd : 16.48 Toilet Paper Dispenser 16.49 Seat Cover Dispenser Does the toilet paper dispenser allow continuous paper delivery? 604.7 /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B.8.3 16.50 Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A 16.51 Grab Bar Diameter 16.52 Grab Bar Wall Clearance 16.53 Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? 609.2 /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? 609.3 /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? 609.3 /// 40 **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions. 16.54 Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? 609.5 /// 1115B.7.3 16.55 Side Grab Bar Does the side grab bar extend at least 54 min beyond the rear wall while the other end is a maximum of 12 from the rear wall, with the front end positioned 24 min. in front of the WC? 604.5.1 /// 1115B.4.1 item 3.1 16.56 Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? 604.5.2 /// 1115B.4.1 item 3.2 16.57 Semi- Ambulant Stall 16.58 Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? 604.8.2 /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? 604.8.2.3 /// 1115B.3.1 item 5, 1115B.4.1 item 3 16.59 Urinals Where urinals are provided, does at least one comply with the requirements below? 213.3.3 /// 1115B.4.2 52 from rear wall. Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Page 5 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 3rd : TR5 : 3rd : 16.60 Urinal Rim Height 16.61 Clear at Urinal 16.62 Width Between Screens at Urinal 16.63 Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? 605.2 /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, 305.7.1 /// 1118B.4 item 2, Fig. 11B-5A(b) 16.64 Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? 213.3.4 /// 1115B.4.3 16.65 Lavaty Rim Height 16.66 Lavaty Apron Clearance 16.67 Lavaty Knee Clearance 16.68 Lavaty Wall ion 16.69 Clear at Lavaty 16.70 Side Clearance at Lavaty 16.71 Lavaty Location 16.72 Pipe Insulation at Lavaty 16.73 Smooth Surfaces at Lavaty 16.74 Faucet Operation at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? 606.3 /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? 606.2 /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? 606.2 /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item 2 Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? 606.5 /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? 606.5 /// 1115B.4.3 item 4 Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? 606.4 /// 1115B.4.3 item 1 Left Side: 34-1/8 Right Side: 33-7/8 Page 6 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom 3rd : TR5 : 3rd : 16.75 Faucet Operation at Lavaty If the valve is self-closing, does it remain open f at least 10 seconds? 606.4 /// 1115B.4.3 item 1 16.76 Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? 603.3 /// 1115B.8.1 16.77 Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? 604.8.3 /// 1117B.8 16.78 Dispensers Operating Height 16.79 at Dispensers 16.80 Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? 305.3 /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item 4 16.81 Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// 907.9.1, 907.9.2, 1114B.2.2 37-1/2 40 Paper towel: OK. 16.82 Other slopes are good. NOTES: Typical 3rd Men s and Women s Restrooms. (Dimensions Approximate) Code Clearance Page 7 of 7

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Women s Shower 3rd TR5 : Shower : 3rd : 17.1 17.2 17.3 17.4 17.5 17.6 17.7 17.8 17.9 17.10 17.11 17.12 17.13 30 x 60 Shower Stall Design 30 x 60 Shower Stall Design Alternate Roll-In Shower Stall Design Alternate Roll-In Shower Stall Design Design Design Seating Seating Seating Seating Seating Seating Seating Is the roll-in shower a minimum 60 in width between wall surfaces and a minimum 30 in depth with a full opening width on the long side. 608.2.2 /// 1115B.4.4.1.1 Is the clear flo space that adjoins the shower compartment a minimum of 36 x 60? 608.2.2 /// 1115B.4.4.1.1 Is the roll-in shower a minimum 36 x 60 with a minimum entry width of 36? 608.2.3 /// 1115B.4.4.1.2 Is there a minimum 36 wide clear flo space adjoining the shower seat to allow f parallel transfer? 608.2.3 /// 1115B.4.4.1.2 Is the surface slope at 2% less in any direction? 304.2 /// 1115B.4.4.7 Where drains are provided, are the grate openings minimum of ¼ and located flush with the flo surface? 302.3 ///1115B.4.4.7 Is there a folding seat mounted 18 above flo? Is the clearance from the seat to the adjacent wall surfaces minimum of 1 and a maximum of 1 ½? 608.4, 610.3 /// 1115B.4.4.8.1 When folded, does the shower seat extend a maximum 6 from the mounting (back) wall? ///1115B.4.4.8.1 Does the folding seat extend the full-required depth of the stall? 610.3 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 15 from the adjacent wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 23 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the narrow ption of the seat extend a maximum of 16 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the shower seat provide a minimum Structural strength to suppt a 250 lb point load? 610.4 /// 1115B.4.4.8.1, 1115B.7.2 As-built Dimensions 43 x 59-11/16 Entry width at 35-13/16 3.3% - 3.6% Seat mounted 3-1/8 off back wall. Height 18-1/2 at front of seat due to flo slope. 5-1/2 16-1/2 (seat mounted 3-1/8 off back wall) 22-1/2 16 Page 1 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Women s Shower 3rd TR5 : Shower : 3rd : 17.14 Grab Bar Are grab bars located on walls adjacent to and opposite the seat? 608.3 /// 1115B.4.4.8.2, Fig. 11A, 11B As-built Dimensions 17.15 17.16 17.17 17.18 17.19 17.20 17.21 17.22 17.23 17.24 17.25 17.26 17.27 Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Design Controls Controls Controls Controls Controls Is grab bar L-shaped and continuous along the wall opposite from and adjacent to the seat? (But NOT extended to include the ption of wall over the seat) 608.3 /// 1115B.4.4.8.2 Are grab bars mounted between 33 36 above flo surface? 609.4 /// 1115B.4.4.8.2 Are grab bars between 1 ¼ 1 ½ diameter equivalent? 609.2 /// 1115B.7.1 Is the clearance between the wall and grab bar 1 ½? 609.3 /// 1115B.7.1 Are the bars smooth with a minimum radius of 1/8? 609.5 /// 1115B.4.1.3, 1115B.7.3 Do the bars provide a minimum structural strength to suppt a 250lb point load? 609.8 /// 1115B.7.1.2 thru.4 Are the grab bars stable and do not rotate within their fittings? 609.6 /// 1115B.7.2.5 Is the water valve control a single lever type? 608.5 /// 1115B.4.4.4 Is the centerline of the control located on the side wall of the compartment adjacent to the seat within reach range of no less than 19 and no me than 24 from the rear edge of the seat? 608.5.2, 608.5.3 /// 1115B.4.4.4.1 Is the fce to operate the controls a maximum of 5lbs? 309.4 /// 1115B.4.4.4 Is the centerline of the control valves between 39 to 41 above the shower flo? 608.5.2, 608.5.3 /// 1115B.4.4.4 Are the controls operable with one hand and do not require tight grasping, pinching twisting of the wrist? 309.4 /// 1115B.4.4.4 Is a flexible hand held spray unit with a hose at least 60 long that can be used both as a fixed shower head and as a hand-held shower provided and mounted such that the top of the mounting bracket is at a maximum height of 48 from the flo? 608.6 /// 1115B.4.4.5 33 1-1/2 Grab bar is loose. Control Valve at 23 Diverter Valve at 12-1/4 Diverter valve should be located with-in the control area of 19 24 from the rear edge of the seat. 39-5/8 43 High Page 2 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Women s Shower 3rd TR5 : Shower : 3rd : 17.28 17.29 17.30 17.31 Controls Design Design Is the hand-held sprayer unit located on the back wall of the compartment adjacent to the seat, and the centerline of the control is no me than 27 from the seat wall? 608.5.2, 608.5.3 /// 1115B.4.4.5 Is the soap dish mounted on the control wall at 40 maximum height and within reach limits from the seat? /// 1115B.4.4.9 Where lockers are provided f the public, clients, employees, members, participants, is at least one and not less than 5% of all lockers accessible. Is a path of travel not less than 36 in clear width provided to these lockers? 225.2.1 /// 1115B.8.5, 1115B.2 As-built Dimensions 9 from the wall. No soap dish. Other Hooks at 48 and 54 AFF Do not meet required reach ranges no higher than 48. Lower add hook at a height not greater than 48. NOTES: Page 3 of 3

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 3rd : TR6 : 3rd : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B.1 16.2 Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? 213.2 /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? 213.2 /// 1115B.1.1 Is the toilet room located on an accessible route of travel? 206.2.4 /// 1115B.1 16.5 Entry Dos Does the do comply with the requirements below? 404 /// 1115B.5 16.6 Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? 404.2.3 /// 1133B.2.2 16.7 Do Swing Does the do swing not intrude into the clear flo space at any fixture? 404.2.3 /// 1115B.5 16.8 Do Maneuvering 16.9 Do Hardware 16.10 Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7 /// 1133B.2.5.2 Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 16.11 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 >12 lbs Adjust closer. Page 1 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 3rd : TR6 : 3rd : 16.12 Identification Symbols 16.13 Identification Symbols 16.14 Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? 216.2 /// 1117B.5.1 item 1 16.15 Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? 703.1 /// 1117B.5.1 item 2 16.16 Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? 703.6 /// 1117B.5.5 item 3 16.17 ISA If the toilet room is accessible, is the room identified by an ISA? 216.8 /// 1117B.5.1 item 3 16.18 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 16.19 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 16.20 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 16.21 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 16.22 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 59-1/4 Page 2 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 3rd : TR6 : 3rd : 16.23 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 16.24 Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 16.25 Surface Is the surface of the toilet room stable, firm, and slip resistant? 302.1 /// 1124B.1 16.26 Maneuvering 16.27 Maneuvering 16.28 Maneuvering 16.29 Stall Do Width 16.30 Stall Do Width 16.31 Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.). 603.2 /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than 12. 603.2.3 /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? 206.2.4 /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? 604.8.1.2 /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? 604.8.1.2 /// 1115B.3.1 item 4.5 16.32 Stall Do Is the stall do self-closing? 604.8.1.2 /// 1115B.3.1 item 4.4 16.33 Stall Do Strike Edge 16.34 Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? 604.8.1.2 /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? 604.8.1.2 /// 1115B.3.1 item 4.3 16.35 Stall Width Is the stall at least 60 wide? 604.8.1.1 /// 1115B.3.1 item 4.1 See approximate dimensions below. See approximate dimensions below. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. 34-1/2 Hardware on pull side only. 59 Page 3 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 3rd : TR6 : 3rd : 16.36 Stall Maneuvering 16.37 Stall Maneuvering 16.38 Stall Maneuvering 16.39 Stall Do Location 16.40 Maneuvering 16.41 Maneuvering 16.42 WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? 604.8.1.1 /// 1115B.3.1 item 4.2 Stall width is 59. If the stall has an in-swinging side entry stall do, is Stall depth is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep not allow f the 86-1/4 which does space f flo-mounted WC? (Toilet compartment 56 minimum deep dos shall not swing into the minimum required space. See sketch compartment area.) below. 604.8.1.1, 604.8.1.2 /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? 604.8.1.2 /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A 16.43 WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? 604.2 /// 1115B.4.1 item 1 16.44 WC Seat Is the top of the WC seat between 17 and 19 AFF? 604.4 /// 1115B.4.1 item 4 16.45 WC Flush Controls 16.46 Toilet Paper Dispenser 16.47 Toilet Paper Dispenser Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? 604.6 /// 1115B.4.1 item 5 Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? 604.7 /// 1115B.8.4 **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. Is the toilet paper dispenser mounted below the side grab bar? 604.7 /// 1115B.8.4 31-1/2 19-1/2 18 37 from back wall. Bottom roll: 20 Top roll: 28 Dispenser needs to be mounted within 36 minimum from the rear wall a minimum of 7 and a maximum of 9 in front of the water closet per the new code. Page 4 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 3rd : TR6 : 3rd : 16.48 Toilet Paper Dispenser 16.49 Seat Cover Dispenser Does the toilet paper dispenser allow continuous paper delivery? 604.7 /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B.8.3 16.50 Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A 16.51 Grab Bar Diameter 16.52 Grab Bar Wall Clearance 16.53 Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? 609.2 /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? 609.3 /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? 609.3 /// 40 **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions. 16.54 Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? 609.5 /// 1115B.7.3 16.55 Side Grab Bar Does the side grab bar extend at least 54 min beyond 50-1/2 from rear the rear wall while the other end is a maximum of 12 wall. from the rear wall, with the front end positioned 24 min. in front of the WC? 604.5.1 /// 1115B.4.1 item 3.1 16.56 Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? 604.5.2 /// 1115B.4.1 item 3.2 16.57 Semi- Ambulant Stall 16.58 Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? 604.8.2 /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? 604.8.2.3 /// 1115B.3.1 item 5, 1115B.4.1 item 3 16.59 Urinals Where urinals are provided, does at least one comply with the requirements below? 213.3.3 /// 1115B.4.2 Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Page 5 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 3rd : TR6 : 3rd : 16.60 Urinal Rim Height 16.61 Clear at Urinal 16.62 Width Between Screens at Urinal 16.63 Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? 605.2 /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, 305.7.1 /// 1118B.4 item 2, Fig. 11B-5A(b) 16.64 Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? 213.3.4 /// 1115B.4.3 16.65 Lavaty Rim Height 16.66 Lavaty Apron Clearance 16.67 Lavaty Knee Clearance 16.68 Lavaty Wall ion 16.69 Clear at Lavaty 16.70 Side Clearance at Lavaty 16.71 Lavaty Location 16.72 Pipe Insulation at Lavaty 16.73 Smooth Surfaces at Lavaty 16.74 Faucet Operation at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? 606.3 /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? 606.2 /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? 606.2 /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item 2 Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? 606.5 /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? 606.5 /// 1115B.4.3 item 4 Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? 606.4 /// 1115B.4.3 item 1 14 & 16 35 @ 22 deep Left Side: 34-1/4 Right Side: 34-1/4 Page 6 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom 3rd : TR6 : 3rd : 16.75 Faucet Operation at Lavaty If the valve is self-closing, does it remain open f at least 10 seconds? 606.4 /// 1115B.4.3 item 1 16.76 Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? 603.3 /// 1115B.8.1 16.77 Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? 604.8.3 /// 1117B.8 16.78 Dispensers Operating Height 16.79 at Dispensers 16.80 Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? 305.3 /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item 4 16.81 Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// 907.9.1, 907.9.2, 1114B.2.2 37-3/4 40 Paper towel: OK. 16.82 Other NOTES: Typical 3rd Men s and Women s Restrooms. (Dimensions Approximate) Code Clearance Page 7 of 7

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Men s Shower 3rd TR6 : Shower : 3rd : 17.1 17.2 17.3 17.4 17.5 17.6 17.7 17.8 17.9 17.10 17.11 17.12 17.13 17.14 30 x 60 Shower Stall Design 30 x 60 Shower Stall Design Alternate Roll-In Shower Stall Design Alternate Roll-In Shower Stall Design Design Design Seating Seating Seating Seating Seating Seating Seating Grab Bar Is the roll-in shower a minimum 60 in width between wall surfaces and a minimum 30 in depth with a full opening width on the long side. 608.2.2 /// 1115B.4.4.1.1 Is the clear flo space that adjoins the shower compartment a minimum of 36 x 60? 608.2.2 /// 1115B.4.4.1.1 Is the roll-in shower a minimum 36 x 60 with a minimum entry width of 36? 608.2.3 /// 1115B.4.4.1.2 Is there a minimum 36 wide clear flo space adjoining the shower seat to allow f parallel transfer? 608.2.3 /// 1115B.4.4.1.2 Is the surface slope at 2% less in any direction? 304.2 /// 1115B.4.4.7 Where drains are provided, are the grate openings minimum of ¼ and located flush with the flo surface? 302.3 ///1115B.4.4.7 Is there a folding seat mounted 18 above flo? Is the clearance from the seat to the adjacent wall surfaces minimum of 1 and a maximum of 1 ½? 608.4, 610.3 /// 1115B.4.4.8.1 When folded, does the shower seat extend a maximum 6 from the mounting (back) wall? ///1115B.4.4.8.1 Does the folding seat extend the full-required depth of the stall? 610.3 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 15 from the adjacent wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the wide ption of the seat extend a maximum of 23 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the narrow ption of the seat extend a maximum of 16 from the mounting (back) wall? 610.3.2 /// 1115B.4.4.8.1, Fig. 11B-2D Does the shower seat provide a minimum Structural strength to suppt a 250 lb point load? 610.4 /// 1115B.4.4.8.1, 1115B.7.2 Are grab bars located on walls adjacent to and opposite the seat? 608.3 /// 1115B.4.4.8.2, Fig. 11A, 11B As-built Dimensions 42 x 59-9/16 Entry width at 35-1/2 3.5% Seat mounted 3 off back wall. Height 18-1/2 at front of seat due to flo slope. 5-1/2 16-3/8 (seat mounted 3 off back wall) 22-3/8 16 Page 1 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Men s Shower 3rd TR6 : Shower : 3rd : 17.15 17.16 17.17 17.18 17.19 17.20 17.21 17.22 17.23 17.24 17.25 17.26 17.27 17.28 Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Design Controls Controls Controls Controls Controls Controls Is grab bar L-shaped and continuous along the wall opposite from and adjacent to the seat? (But NOT extended to include the ption of wall over the seat) 608.3 /// 1115B.4.4.8.2 Are grab bars mounted between 33 36 above flo surface? 609.4 /// 1115B.4.4.8.2 Are grab bars between 1 ¼ 1 ½ diameter equivalent? 609.2 /// 1115B.7.1 Is the clearance between the wall and grab bar 1 ½? 609.3 /// 1115B.7.1 Are the bars smooth with a minimum radius of 1/8? 609.5 /// 1115B.4.1.3, 1115B.7.3 Do the bars provide a minimum structural strength to suppt a 250lb point load? 609.8 /// 1115B.7.1.2 thru.4 Are the grab bars stable and do not rotate within their fittings? 609.6 /// 1115B.7.2.5 Is the water valve control a single lever type? 608.5 /// 1115B.4.4.4 Is the centerline of the control located on the side wall of the compartment adjacent to the seat within reach range of no less than 19 and no me than 24 from the rear edge of the seat? 608.5.2, 608.5.3 /// 1115B.4.4.4.1 Is the fce to operate the controls a maximum of 5lbs? 309.4 /// 1115B.4.4.4 Is the centerline of the control valves between 39 to 41 above the shower flo? 608.5.2, 608.5.3 /// 1115B.4.4.4 Are the controls operable with one hand and do not require tight grasping, pinching twisting of the wrist? 309.4 /// 1115B.4.4.4 Is a flexible hand held spray unit with a hose at least 60 long that can be used both as a fixed shower head and as a hand-held shower provided and mounted such that the top of the mounting bracket is at a maximum height of 48 from the flo? 608.6 /// 1115B.4.4.5 Is the hand-held sprayer unit located on the back wall of the compartment adjacent to the seat, and the centerline of the control is no me than 27 from the seat wall? 608.5.2, 608.5.3 /// 1115B.4.4.5 As-built Dimensions 33 1-1/2 Control Valve at 22-3/4 Diverter Valve at 12-1/2 Diverter valve should be located with-in the control area of 19 24 from the rear edge of the seat. 39-3/4 43 High 9 from the wall. Page 2 of 3

SHOWER FACILITY Survey Fm 17 /Room 30 Liberty Ship Way Name: Men s Shower 3rd TR6 : Shower : 3rd : 17.29 17.30 17.31 Design Design Is the soap dish mounted on the control wall at 40 maximum height and within reach limits from the seat? /// 1115B.4.4.9 Where lockers are provided f the public, clients, employees, members, participants, is at least one and not less than 5% of all lockers accessible. Is a path of travel not less than 36 in clear width provided to these lockers? As-built Dimensions No soap dish. 225.2.1 /// 1115B.8.5, 1115B.2 Other Hooks at 47-1/2 and 53-1/2 AFF Do not meet required reach ranges no higher than 48. Lower add hook at a height not greater than 48. NOTES: Page 3 of 3

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom Exteri : TR7 : Exteri : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B.1 16.2 Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? 213.2 /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? 213.2 /// 1115B.1.1 Is the toilet room located on an accessible route of travel? 206.2.4 /// 1115B.1 16.5 Entry Dos Does the do comply with the requirements below? 404 /// 1115B.5 16.6 Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? 404.2.3 /// 1133B.2.2 16.7 Do Swing Does the do swing not intrude into the clear flo space at any fixture? 404.2.3 /// 1115B.5 16.8 Do Maneuvering 16.9 Do Hardware 16.10 Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7 /// 1133B.2.5.2 Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 Lock at 49-1/2 Hardware to be mounted between 30 and 44 AFF. 404.2.7 /// 1133B.2.5.2 >26 lbs Adjust closer. Page 1 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom Exteri : TR7 : Exteri : 16.11 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 16.12 Identification Symbols 16.13 Identification Symbols 16.14 Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? 216.2 /// 1117B.5.1 item 1 16.15 Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? 703.1 /// 1117B.5.1 item 2 16.16 Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? 703.6 /// 1117B.5.5 item 3 16.17 ISA If the toilet room is accessible, is the room identified by an ISA? 216.8 /// 1117B.5.1 item 3 16.18 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 16.19 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 16.20 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 16.21 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 Fast Adjust closer. No Signage No Signage Page 2 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom Exteri : TR7 : Exteri : 16.22 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 16.23 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 16.24 Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 16.25 Surface Is the surface of the toilet room stable, firm, and slip resistant? 302.1 /// 1124B.1 16.26 Maneuvering 16.27 Maneuvering 16.28 Maneuvering 16.29 Stall Do Width 16.30 Stall Do Width 16.31 Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.). 603.2 /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than 12. 603.2.3 /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? 206.2.4 /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? 604.8.1.2 /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? 604.8.1.2 /// 1115B.3.1 item 4.5 16.32 Stall Do Is the stall do self-closing? 604.8.1.2 /// 1115B.3.1 item 4.4 16.33 Stall Do Strike Edge 16.34 Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? 604.8.1.2 /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? 604.8.1.2 /// 1115B.3.1 item 4.3 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. Page 3 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom Exteri : TR7 : Exteri : 16.35 Stall Width Is the stall at least 60 wide? 604.8.1.1 /// 1115B.3.1 item 4.1 16.36 Stall Maneuvering 16.37 Stall Maneuvering 16.38 Stall Maneuvering 16.39 Stall Do Location 16.40 Maneuvering 16.41 Maneuvering 16.42 WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? 604.8.1.1 /// 1115B.3.1 item 4.2 If the stall has an in-swinging side entry stall do, is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep space f flo-mounted WC? (Toilet compartment dos shall not swing into the minimum required compartment area.) 604.8.1.1, 604.8.1.2 /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? 604.8.1.2 /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A 16.43 WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? 604.2 /// 1115B.4.1 item 1 16.44 WC Seat Is the top of the WC seat between 17 and 19 AFF? 604.4 /// 1115B.4.1 item 4 16.45 WC Flush Controls 16.46 Toilet Paper Dispenser Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? 604.6 /// 1115B.4.1 item 5 Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? 604.7 /// 1115B.8.4 **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. 28 42-13/16 18-3/4 38 from back wall. Bottom roll: 20-1/2 Top roll: 28-1/2 Dispenser needs to be mounted within 36 minimum from the rear wall a minimum of 7 and a maximum of 9 in front of the water closet per the new code. Page 4 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom Exteri : TR7 : Exteri : 16.47 Toilet Paper Dispenser 16.48 Toilet Paper Dispenser 16.49 Seat Cover Dispenser Is the toilet paper dispenser mounted below the side grab bar? 604.7 /// 1115B.8.4 Does the toilet paper dispenser allow continuous paper delivery? 604.7 /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B.8.3 16.50 Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A 16.51 Grab Bar Diameter 16.52 Grab Bar Wall Clearance 16.53 Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? 609.2 /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? 609.3 /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? 609.3 /// 40 **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions. 16.54 Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? 609.5 /// 1115B.7.3 16.55 Side Grab Bar Does the side grab bar extend at least 54 min beyond the rear wall while the other end is a maximum of 12 from the rear wall, with the front end positioned 24 min. in front of the WC? 604.5.1 /// 1115B.4.1 item 3.1 16.56 Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? 604.5.2 /// 1115B.4.1 item 3.2 16.57 Semi- Ambulant Stall 16.58 Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? 604.8.2 /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? 604.8.2.3 /// 1115B.3.1 item 5, 1115B.4.1 item 3 53 from rear wall. Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Page 5 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom Exteri : TR7 : Exteri : 16.59 Urinals Where urinals are provided, does at least one comply with the requirements below? 213.3.3 /// 1115B.4.2 16.60 Urinal Rim Height 16.61 Clear at Urinal 16.62 Width Between Screens at Urinal 16.63 Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? 605.2 /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, 305.7.1 /// 1118B.4 item 2, Fig. 11B-5A(b) 16.64 Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? 213.3.4 /// 1115B.4.3 16.65 Lavaty Rim Height 16.66 Lavaty Apron Clearance 16.67 Lavaty Knee Clearance 16.68 Lavaty Wall ion 16.69 Clear at Lavaty 16.70 Side Clearance at Lavaty 16.71 Lavaty Location 16.72 Pipe Insulation at Lavaty 16.73 Smooth Surfaces at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? 606.3 /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? 606.2 /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? 606.2 /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item 2 Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? 606.5 /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? 606.5 /// 1115B.4.3 item 4 33-1/4 30-5/8 Page 6 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Women s Restroom Exteri : TR7 : Exteri : 16.74 Faucet Operation at Lavaty 16.75 Faucet Operation at Lavaty Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? 606.4 /// 1115B.4.3 item 1 If the valve is self-closing, does it remain open f at least 10 seconds? 606.4 /// 1115B.4.3 item 1 16.76 Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? 603.3 /// 1115B.8.1 16.77 Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? 604.8.3 /// 1117B.8 16.78 Dispensers Operating Height 16.79 at Dispensers 16.80 Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? 305.3 /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item 4 16.81 Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// 907.9.1, 907.9.2, 1114B.2.2 40-1/8 48 Paper towel: OK Soap: OK Sanitary Napkin Dispenser: OK. 16.82 Other slopes are good. NOTES: Page 7 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom Exteri : TR8 : Exteri : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B.1 16.2 Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? 213.2 /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? 213.2 /// 1115B.1.1 Is the toilet room located on an accessible route of travel? 206.2.4 /// 1115B.1 16.5 Entry Dos Does the do comply with the requirements below? 404 /// 1115B.5 16.6 Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? 404.2.3 /// 1133B.2.2 16.7 Do Swing Does the do swing not intrude into the clear flo space at any fixture? 404.2.3 /// 1115B.5 16.8 Do Maneuvering 16.9 Do Hardware 16.10 Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D + 24 60 Latch Push D + 24 44 *** Hinge Pull D + 36 60 Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer. 404.2.4 /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? 404.2.7 /// 1133B.2.5.2 Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.). 404.2.9 /// 1133B.2.5 Lock at 49-1/2 Hardware to be mounted between 30 and 44 AFF. 404.2.7 /// 1133B.2.5.2 >22 lbs Adjust closer. Page 1 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom Exteri : TR8 : Exteri : 16.11 Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? 404.2.8 /// 1133B.2.5.1 16.12 Identification Symbols 16.13 Identification Symbols 16.14 Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? 216.2 /// 1117B.5.1 item 1 16.15 Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? 703.1 /// 1117B.5.1 item 2 16.16 Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? 703.6 /// 1117B.5.5 item 3 16.17 ISA If the toilet room is accessible, is the room identified by an ISA? 216.8 /// 1117B.5.1 item 3 16.18 Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) 703.4.1 /// 1117B.5.7 16.19 Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? 703.4.2 /// 1117B.5.7 16.20 Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? 703.3.2 /// 1117B.5.5 items 1& 4, 1117B.5.6 16.21 Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? 703.2.1, 703.2.5 /// 1117B.5.5 items 1 & 2 No Signage No Signage Page 2 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom Exteri : TR8 : Exteri : 16.22 Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? 703.2.2, 703.2.3 /// 1117B.5.5.1 16.23 Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? 703.5.1 /// 1117B.5.2 16.24 Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 16.25 Surface Is the surface of the toilet room stable, firm, and slip resistant? 302.1 /// 1124B.1 16.26 Maneuvering 16.27 Maneuvering 16.28 Maneuvering 16.29 Stall Do Width 16.30 Stall Do Width 16.31 Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.). 603.2 /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than 12. 603.2.3 /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? 206.2.4 /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? 604.8.1.2 /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? 604.8.1.2 /// 1115B.3.1 item 4.5 16.32 Stall Do Is the stall do self-closing? 604.8.1.2 /// 1115B.3.1 item 4.4 16.33 Stall Do Strike Edge 16.34 Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? 604.8.1.2 /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? 604.8.1.2 /// 1115B.3.1 item 4.3 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, 2012. Page 3 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom Exteri : TR8 : Exteri : 16.35 Stall Width Is the stall at least 60 wide? 604.8.1.1 /// 1115B.3.1 item 4.1 16.36 Stall Maneuvering 16.37 Stall Maneuvering 16.38 Stall Maneuvering 16.39 Stall Do Location 16.40 Maneuvering 16.41 Maneuvering 16.42 WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? 604.8.1.1 /// 1115B.3.1 item 4.2 If the stall has an in-swinging side entry stall do, is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep space f flo-mounted WC? (Toilet compartment dos shall not swing into the minimum required compartment area.) 604.8.1.1, 604.8.1.2 /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? 604.8.1.2 /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A 16.43 WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? 604.2 /// 1115B.4.1 item 1 16.44 WC Seat Is the top of the WC seat between 17 and 19 AFF? 604.4 /// 1115B.4.1 item 4 16.45 WC Flush Controls 16.46 Toilet Paper Dispenser Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? 604.6 /// 1115B.4.1 item 5 Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? 604.7 /// 1115B.8.4 **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. 29 42-3/4 18-3/4 17-1/2 37-1/2 from back wall. Bottom roll: 20-1/4 Top roll: 28-1/4 Dispenser needs to be mounted within 36 minimum from the rear wall a minimum of 7 and a maximum of 9 in front of the water closet per the new code. Page 4 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom Exteri : TR8 : Exteri : 16.47 Toilet Paper Dispenser 16.48 Toilet Paper Dispenser 16.49 Seat Cover Dispenser Is the toilet paper dispenser mounted below the side grab bar? 604.7 /// 1115B.8.4 Does the toilet paper dispenser allow continuous paper delivery? 604.7 /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B.8.3 16.50 Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A 16.51 Grab Bar Diameter 16.52 Grab Bar Wall Clearance 16.53 Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? 609.2 /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? 609.3 /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? 609.3 /// 40 1-1/2 to top toilet paper roll. See Save Harb provisions. **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions. 16.54 Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? 609.5 /// 1115B.7.3 16.55 Side Grab Bar Does the side grab bar extend at least 54 min beyond the rear wall while the other end is a maximum of 12 from the rear wall, with the front end positioned 24 min. in front of the WC? 604.5.1 /// 1115B.4.1 item 3.1 16.56 Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? 604.5.2 /// 1115B.4.1 item 3.2 16.57 Semi- Ambulant Stall 16.58 Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? 604.8.2 /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? 604.8.2.3 /// 1115B.3.1 item 5, 1115B.4.1 item 3 51 from rear wall. Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Page 5 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom Exteri : TR8 : Exteri : 16.59 Urinals Where urinals are provided, does at least one comply with the requirements below? 213.3.3 /// 1115B.4.2 16.60 Urinal Rim Height 16.61 Clear at Urinal 16.62 Width Between Screens at Urinal 16.63 Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? 605.2 /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? 605.3 /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, 305.7.1 /// 1118B.4 item 2, Fig. 11B-5A(b) 16.64 Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? 213.3.4 /// 1115B.4.3 16.65 Lavaty Rim Height 16.66 Lavaty Apron Clearance 16.67 Lavaty Knee Clearance 16.68 Lavaty Wall ion 16.69 Clear at Lavaty 16.70 Side Clearance at Lavaty 16.71 Lavaty Location 16.72 Pipe Insulation at Lavaty 16.73 Smooth Surfaces at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? 606.3 /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? 606.2 /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? 606.2 /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item 2 Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? 606.5 /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? 606.5 /// 1115B.4.3 item 4 33-5/8 30-3/4 Page 6 of 7

TOILET FACLITIES Survey Fm 16 /Room 30 Liberty Ship Way Name: Men s Restroom Exteri : TR8 : Exteri : 16.74 Faucet Operation at Lavaty 16.75 Faucet Operation at Lavaty Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? 606.4 /// 1115B.4.3 item 1 If the valve is self-closing, does it remain open f at least 10 seconds? 606.4 /// 1115B.4.3 item 1 16.76 Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? 603.3 /// 1115B.8.1 16.77 Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? 604.8.3 /// 1117B.8 16.78 Dispensers Operating Height 16.79 at Dispensers 16.80 Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? 305.3 /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item 4 16.81 Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// 907.9.1, 907.9.2, 1114B.2.2 40-1/8 48 Paper towel: OK Soap: OK. 16.82 Other slopes are good. NOTES: Page 7 of 7