SAE J1939 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions

Similar documents
CTR Series. Turbine low meters with conditioned output and built-in loading valve. Up to. Output Options. Features. Hydraulic measurement and control

Before first operating the equipment read the whole of these instructions. Safety may be impaired if they are not followed.

GPM Hydraulic Flow Meter User Manual

2FV2V Series Variable Priority Flow Dividers

hydraulic flow meter Author:

Analog Hydraulic Testers

WP Series Hydraulic & Pneumatic Flow Monitors Illustrated Price List

Webster Instruments. (A division of Webtec Products) Product Overview. The Webster Range of Hydraulic Test Equipment

Volume flow measurement

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

Hydraulic Diagnostic Products. Fixed Position and Portable Equipment. Catalog

Short Form Catalogue

Product Summary. Flow Meters. Hydraulic Diagnostic Products

Contents. Quality Hydraulic Components from the Webtec Range. Introduction. Hydraulic Flow Control Valves

INSERTION flowmeter with paddle wheel, ELEMENT design

Paddle-wheel flow controller with optical principle for On/Off control

Low Pressure Filters

INSERTION flow sensor for continuous flow measurement

Simple to use portable hydraulic testers...

PSF50 Paddle flow switch

mass flowmeter for compressed air

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Electronic Pressure Switches

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Insertion magnetic inductive flowmeter

Thermostatic Control Valve

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control

A1 Commercial Grade Meters

ISTEC MAGNETIC METERS

A1 Commercial Grade Meters

SINGLE ACTING METRIC RANGE

Intelligent Positioner

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

Electronic Pressure Switches

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

G2 Industrial Grade Meters

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

VHS... Screw Flow Meter

Model TUR-200D Turbine Flowmeter

Technical Datasheet. HM AC Series. Turbine Flow Meters. for High Pressure Applications up to 1,400 bar

mass flowmeter for compressed air

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

VLM20 In-line Vortex Flowmeter

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Positive displacement batch controller

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Electronic Pressure Switches

Fixed Displacement Bent Axis Axial Piston Motors TMB 700

8000 Series Liquid Flow Meters

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Inductive conductivity meter

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Directional Control Valves

Data Sheet. I/P and E/P converters. RS stock numbers ,

P.C. Priority Flow Control Valve Series J02D3. General Description

CMA200 Advanced Subject Independent-Metering title Mobile Valve. 200LPM 440 bar CAN Bus

Full Range Pressure Compensating Variable Flow Control

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

INSTRUMENTATION & CONTROL

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

Product Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

BM SERIES METERS PRECISION POSITIVE DISPLACEMENT METERS THE LEADER IN ACCURATE, LONG-LIFE, FUEL METERING INDUSTRY LEADING ACCURACY (+/-.

Technical Datasheet. HM R Series. Turbine Flow Meters. with Female Inch Threads

10 Pressure/temperature measurement SCPT analogue

High Performance Turbine Technology

ACTUATORS POSITION SENSOR

7829 Visconic industrial viscosity transmitter on line real time viscosity measurement

HEC2003/2004 Series Servo Valve System

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

Proportional flow control valve, 2-way version

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Positive displacement flowmeter

Series PVP Variable Volume Piston Pumps

EZ-View. Flow Meters ISO CERTIFIED 9001

PA - Turbine Flowmeter Range

Chapter 5: Flow Valves

12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-on filtration.

VSO - MI thermally compensated proportional valve

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Adjustment range. Seal material. Pressure connection

Turbine flowmeters Series TM

Inductive conductivity meter

digital flow meters BW Digi-Meter F-1000

Keystone F89 pneumatic quarter-turn actuator General purpose / hazardous area

KEYSTONE F89 pneumatic quarter-turn actuator GENERAL PURPOSE / HAZARDOUS AREA

Electronic Pressure Switches

Air Operated Stainless Steel 6000psi Ball Valve

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

UNIK Pressure Sensing Platform. GE Sensing & Inspection Technologies. Features

MX-SERIES OVAL GEAR FLOW METERS

Technical Datasheet. HM U Series. Turbine Flow Meters. for lubricating liquids

Transcription:

SAE J99 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions Milwaukee, WI, USA Tel: + () 769-600 sales-us@webtec.com St. Ives, Cambs. PE7 LZ, UK Tel: + (0) 80 97 00 sales-uk@webtec.com www.webtec.com Up to 00 lpm, 00 US gpm flow measurement 000 bar, 00 psi pressure measurement Wide range of cables and accessories available The CT turbine flow meter range with J99 compatible output provides a convenient solution to measure flow and temperature in hydraulic systems. The flow meter can be installed anywhere in the hydraulic circuit for production testing, commissioning, development testing and analysis of control systems. With the addition of the manual loading valve on the CTR meters further test scenarios can be simulated and monitored such as pump efficiency. Pressure sensors with J99 capability are also available to complement the CT Flow meters. With a pressure sensor all the fundamental parameters of a hydraulic system can be monitored in a single, compact unit with one cable supporting the J99 protocol. Features Flowmeters FLOW: -00 lpm 0. - 00 US gpm PRESSURE: Up to 80 bar, 7000 psi PORTING: BSPP or SAE Bi-directional operation Built-in loading valve optional OUTPUT: SAE J99 CAN compatible (configured to customer s specification) FLUIDS: Wide range of hydraulic oil, lubrication oils, and fuels CALIBRATION: cst as standard. Special calibration possible CONSULT SALES for our hydraulic sensors with CAN OPEN, V and ma outputs Pressure Transducers PRESSURE TRANSDUCERS Pressure: 0 to 000 bar (0-00 psi) OUTPUT: SAE J99 Hydraulic measurement and control CTJ99-BU-ENG-9.pdf 0/9 (Issue.0)

Specifications Model Number Main ports Top ports* Flow range Max. pressure CT-J9-B-B-6 / BSPP / BSPP - lpm 0 bar CT-J9-S-S-6 / -6UN #8 SAE ORB 7/6-0UN # SAE ORB 0. - US gpm 6000 psi CT60-J9-B-B-6 / BSPP / BSPP - 60 lpm 0 bar CT60-J9-S-S-6 -/6 -UN # SAE ORB 7/6-0UN # SAE ORB 0.8-6 US gpm 6000 psi CT0-J9-B-B-6 / BSPP / BSPP - 0 lpm 0 bar CT0-J9-S-S-6 -/6 -UN # SAE ORB 7/6-0UN # SAE ORB. - 0 US gpm 6000 psi CT00-J9-B-B-6 BSPP / BSPP 8-00 lpm 0 bar CT00-J9-S-S-6 -/6 -UN #6 SAE ORB 7/6-0UN # SAE ORB - 80 US gpm 6000 psi CT00-J9-B-B-6 BSPP / BSPP 0-00 lpm 0 bar CT00-J9-S-S-6 -/6 -UN #6 SAE ORB 7/6-0UN # SAE ORB. - 00 US gpm 6000 psi CT600-J9-B-B- -/ BSPP / BSPP - 600 lpm 0 bar CT600-J9-F-S- -/ # SAE Code 6 -bolt flange 7/6-0UN # SAE ORB - 60 US gpm 000 psi CT600-J9-S-S- -/8 -UN #0 SAE ORB 7/6-0UN # SAE ORB - 60 US gpm 000 psi CT800-J9-S-B-7-7/8 -UN # SAE ORB / BSPP 0-800 lpm 80 bar CT800-J9-S-S-7-7/8 -UN # SAE ORB 7/6-0UN # SAE ORB - 0 US gpm 7000 psi CT800-J9-F-B- -/ # SAE Code 6 -bolt flange / BSPP 0-800 lpm 0 bar CT800-J9-F-S- -/ # SAE Code 6 -bolt flange 7/6-0UN # SAE ORB - 0 US gpm 000 psi CT800-J9-F-B-6 -/ # SAE Code 6 -bolt flange / BSPP 0-800 lpm 0 bar CT00-J9-F-S-6 # SAE Code 6 -bolt flange 7/6-0UN # SAE ORB. - 00 US gpm 6000 psi CT00-J9-F-S-6-L # SAE Code 6 -bolt flange 7/6-0UN # SAE ORB 0-00 lpm 0 bar *CT has one of the specified top ports. Model Number Main ports Top ports Flow range Max. pressure CT00R-J9-B-B-6 BSPP / BSPP 8-00 lpm 0 bar CT00R-J9-S-S-6 -/6 -UN #6 SAE ORB 7/6-0UN # SAE ORB - 80 US gpm 6000 psi CT00R-J9-B-B-6 BSPP / BSPP 0-00 lpm 0 bar CT00R-J9-S-S-6 -/6 -UN #6 SAE ORB 7/6-0UN # SAE ORB. - 00 US gpm 6000 psi CT600R-J9-F-B- -/ # SAE Code 6 -bolt flange / BSPP 0-600 lpm 0 bar CT600R-J9-F-S- -/ # SAE Code 6 -bolt flange 7/6-0UN # SAE ORB - 60 US gpm 000 psi CT600R-J9-S-B-7-7/8 -UN # SAE ORB / BSPP 0-600 lpm 80 bar CT600R-J9-S-S-7-7/8 -UN # SAE ORB 7/6-0UN # SAE ORB - 60 US gpm 7000 psi CT800R-J9-F-B- -/ # SAE Code 6 -bolt flange / BSPP 0-800 lpm 0 bar CT800R-J9-S-B-7-7/8 -UN # SAE ORB / BSPP 0-800 lpm 80 bar CT800R-J9-F-S- -/ # SAE Code 6 -bolt flange 7/6-0UN # SAE ORB - 0 US gpm 000 psi CT800R-J9-S-S-7-7/8 -UN # SAE ORB 7/6-0UN # SAE ORB - 0 US gpm 7000 psi CT600R, 800R has limited pressure control below 86 lpm ( US gpm). The maximum controllable pressure in this region is calculated by: max pressure (in bar) = x flow (lpm) +0 Functional specification Ambient temperature: to 0 C ( - 0 F) Fluid type: Mineral oil to ISO 8 category HM (for other fluid types please contact Sales). Fluid temperature: to 90 C ( - 9 F) continuous use. Accuracy: to 00% of range - % of indicated reading Below % fixed accuracy of % of % of full scale (CT is % of full scale) Repeatability: Better than ± 0.% Response Time: 0ms + period (turbine frequency) Degree of protection*: IP66 (EN609) *With cable connected Bus speed: 0KHz Electrical specification Supply voltage (VS): Current: Output: 8-0 VDC ma @v, 0mA @8v SAE J99 compatible (not fully compliant) Calibration: Calibrations are conducted at a mean viscosity of cst using ISO hydraulic mineral oil to ISO8 category HM. Calibration certificates are available on request - this is a chargeable option. Construction material Flow body: 600/800/00 High tensile Aluminium 0A T6 /60/0/00/00 High tensile Aluminium 0 T6 Internal parts: Aluminium, Steel, Stainless Steel. Transducer: Body and nut -steel A electroless nickel plated, Housing and Lid - Aluminium 0 T Seals: FKM seals as standard EPDM are available (For flow meters without loading valve - CT only) - please consult sales office. CTJ99-BU-ENG-9.pdf 0/9 (Issue.0)

Operation As fluid passes through the flow meter it rotates a precision turbine. The turbine is mounted with flow straighteners which are designed to minimize the effects of turbulence. The turbine rotation is detected by a magnetic reluctance transducer that signals RPM to the microcontroller. The microcontroller converts the RPM signal in to an equivalent flow and corrects for dynamic variances to achieve % of indicated flow rate. Temperature is sensed at the tip of the transducer which is in contact with the oil flow. Flow and temperature values are combined by the microcontroller and transmitted in a standard J99 frame format. Reverse Flow The flow block is capable of measuring flow in either direction. Calibration All units are calibrated with cst oil as standard. Calibration certificates are available on request - this is a chargeable option. Production calibration of CT00 lpm turbine is confirmed by testing over the range of 0 to 70 lpm and by design only above 70 lpm. Other calibration on request - please consult the sales office. Installation The flow block has built-in flow straighteners so the normal recommended length of 0 Ø of straight tube can be reduced to 8 Ø where space is limited. Inlet and outlet connections should always be of a similar bore size to that of the flow block to prevent venturi or constriction effects. The range of flow meters can be used for intermittent or continuous testing of flow in either direction. The flow block can be mounted in any orientation. For heavy duty applications where the flow block will be used constantly with continuous pressure spikes please contact sales to discuss your application. Filtration It is recommended that a -micron (0 micron for CT) filter is installed in the circuit prior to the flow block. Top ports Most flow meters have two ports for additional sensors in the top face (see tables for specific configuration). A range of J99 compatible pressure sensors are available to fit these ports. All meters are supplied with one M6x test point fitted as standard. Ordering To order a J99 CT flow meter consult sales to discuss your application and any custom PGN requirements, see identification options on page. Please quote the appropriate model number from the tables, e.g. CT-J9-B-B-6. All flow meters can have a pressure sensor fitted to an auxiliary top port. Quote the required model number from the Pressure Sensor Model Table. Pressure Drop Chart Hydraulic Oil Viscosity Centistokes Pressure Drop (bar) 0.0.0.0 0. CT CT00 CT00 CT60 CT0 CT600, CT800 CT00 0 0 00 00 000 000 Flow (lpm) Note: UK gallon =.6 litres US gallon =.78 litres Pressure Drop (bar) 0.0.0.0 0. M Connection Details CT600R/CT800R CT00R/CT00R 0 0 00 00 000 Flow (lpm) Note UK gallon =.6 litres US gallon =.78 litres Pins = Shield = +In = GND = CAN H = CAN L Cables, Splitters and Terminators: Model Number Description SR-CBL-0.-MF-CAN 0.m cable SR-CBL-0-MF-CAN m cable SR-CBL-0-MF-CAN m cable SR-CBL-0-MF-CAN 0m cable SR-CBL-0-MF-CAN 0m cable SR-CBL-0.0-Y-CAN Y Splitter - no cable SR-CBL-0.-Y-CAN CAN Y splitter, including 0. m cable SR-CBL-000-R-CAN CAN Terminating resistor one per bus CTJ99-BU-ENG-9.pdf 0/9 (Issue.0)

Flow Meter J99 identification options: Option Address PGN Default priority 0x8 0xFF0 6 0x8 0xFF 6 0x8 0xFF 6 (Default) 0x8 (Default) 0xFF (Default) 6 (Default) If Option, or are required, please contact Sales. Pressure sensor model table Model Number Pressure Range: Maximum over-pressure: Pressure Connection Default J99 Address MPT060BBJ 0-60 bar 0 bar / BSPP 00 MPT00BBJ 0 00 bar 00 bar / BSPP 0 MPT60BBJ 0-60 bar 0 bar / BSPP 0 MPT0BBJ 0 0 bar 00 bar / BSPP 0 MPT00BBJ 0 00 bar 800 bar / BSPP 0 MPT600BBJ 0 600 bar 00 bar / BSPP 0 MPTK0BBJ 0-000 bar 00 bar / BSPP 06 MPTK0PUJ 000 psi 70 psi 7/6-0un # SAE ORB 07 MPTKPUJ 00 psi 900 psi 7/6-0un # SAE ORB 08 MPTK0PUJ 000 psi 000 psi 7/6-0un # SAE ORB 09 MPTK0PUJ 000 psi 6000 psi 7/6-0un # SAE ORB 0 MPTK0PUJ 000 psi 0000 psi 7/6-0un # SAE ORB MPT0KPUJ 0000 psi 700 psi 7/6-0un # SAE ORB Please Contact Sales if a different J99 Address is required. Pressure Sensor Specification: Accuracy: ±% of FSD. Power Supply: 0v 0v DC. Current: 0mA. Measuring rate: 00ms Non-Linearity: ±0.% of FSD. Bus speed: 0KHz Temperature drift: 0 60 C: ±0.% of FSD. -0 8 C: ±% of FSD. Additional temperature drift: -0 8 C 0.% per 0 C. Long term stability: ±0.% of FSD per year. Dimensions (mm) ø7 7 Mx G/A DIN8-E ~6 * *7/6-0-A UNF = mm CTJ99-BU-ENG-9.pdf 0/9 (Issue.0)

Dimensions in mm (inches) Model No A B C D E Weight kg (lbs) CT 7 (-/ ) 6 (-/8 ) 7 (-/ ) ( ) 69. (-/ ) 0.7 (.) CT60 6 (-/ ) 90 (7-/ ) 0 ( ) 6 (-/8 ) 0 ( ).6 (.) CT0 6 (-/ ) 90 (7-/ ) 0 ( ) 6 (-/8 ) 0 ( ).6 (.) CT00 6 (-/ ) 90 (7-/ ) 0 ( ) 0 (-/ ) 0 ( ).7 (.7) CT00 6 (-/ ) 90 (7-/ ) 0 ( ) 0 (-/ ) 0 ( ).7 (.7) CT600 6 (-/ ) (8-/8 ) 7 ( ) (6 ) 7 ( ).7 (6) CT600-**-F-*-* 00 ( ) (8-/8 ) 7 ( ) (6 ) 6 ( ).0 () CT800 00 ( ) (8-/8 ) 7 ( ) (6 ) 6 ( ).0 () CT800 (code 6) (-/ ) (8-/8 ) 00 ( ) 6 (6 / ) 6 ( ) 6.0(.) CT00 0 (-/ ) 60 (0-/ ) 00 ( ) 76 (7 )* 0 (-/8 ) 0.0 () * CT00 includes feet on base, add 0 mm (/ ) to D for full height. CT00 is fitted with carry handles - not shown on diagram. E One M6 x test point fitted as standard (Not shown) Pressure / Temp. connections D C A M0 Port B * Note. CT has also one Pressure / Temp connection Dimensions in mm (inches) Model No A B C D E F G Weight kg (lbs) CT00R 9 ( ) 00 ( ) 8 (7-/8 ) (8-/ ) 0. ( ) 7.6 (-7/8 ) 8 (-/ ).7 (8.) CT00R 9 ( ) 00 ( ) 8 (7-/8 ) (8-/ ) 0. ( ) 7.6 (-7/8 ) 8 (-/ ).7 (8.) CT600R 7 ( ) ( ) (8-/8 ) (9-/ ) 99 (-7/8 ) 6 (-/ ) 7 (6-/8 ) 7. (6.) CT800R 7 ( ) ( ) (8-/8 ) (9-/ ) 99 (-7/8 ) 6 (-/ ) 7 (6-/8 ) 7. (6.) Add 0mm (/ ) to G for full height including feet. D CT00R, CT00R position only E All models One M6 x test point fitted as standard (Not shown) G A B F C CT600R, CT800R position only Pressure/Temp connections M0 Port CTJ99-BU-ENG-9.pdf 0/9 (Issue.0)

Turbine Flow Meters Accuracy The accuracy is better described as the uncertainty of the flow reading compared to a known reference. Every flow measurement has an error associated with it, caused by the combination of a large number of factors that affect the operation of the flow meter, these include bearing friction, temperature, viscosity, magnetic drag and the signal strength to name but a few. All our flow meters are calibrated at 0 points over the flow range and its performance measured against a flow reference that is traceable to International standards. Accuracy is typically quoted in one of two ways: as a percentage of full scale (the maximum calibrated flow) or as a percentage of the indicated reading (the actual flow). Full scale (FS) or full scale deflection (FSD) A term that was originally used for analogue displays where a needle pointed to a number on a scale, hence FSD. The flow accuracy is a fixed amount regardless of the actual flow you are measuring. For example % FS for a flow meter with a maximum calibrated flow of 00 lpm is ± lpm whether you are measuring 0 lpm, 00 lpm or 00 lpm (see graph below). If you need to measure flows of 0 and 00 lpm with same flow meter then it is important to check the allowable error at all flows. Error (lpm) Graph showing accuracy of % of Full Scale (FS) for a flow meter rated up to 00 lpm 0 - - - - - Indicated reading (IR) Accuracy is quoted as a percentage of the actual value measured. So if the accuracy of a 00 lpm flow meter is % IR then the error at 00 lpm is ± lpm. As the actual flow measured reduces, so does the error in lpm. When measuring a flow of 60 lpm with an accuracy of % IR, the possible error is ± 0.6 lpm. At very low flows, the possible errors are no longer proportional to the flow rate, but actually a fixed amount in lpm (see graph below). For example if the accuracy is quoted as % IR (>60 lpm) for a flow meter with the range 0-00 lpm, then the accuracy is % of the actual flow in the range 60 to 00 lpm and a fixed flow error in the range 0 to < 60 lpm. APPROVED 0 0 60 80 00 0 0 60 80 00 0 0 60 80 00 0 0 60 80 00 Flow (lpm) Graph showing accuracy of % of Indicated Reading (IR) for a flow meter rated up to 00 lpm Error (lpm) 0 - - - - - 0 0 60 80 00 0 0 60 80 00 0 0 60 80 00 0 0 60 80 00 Flow (lpm ) Repeatability The repeatability is the variation in the performance of the flow meter when used under the same conditions. Our range of flow meters has excellent repeatability of better than ± 0.%. This is just as important as the accuracy since in many applications the flow readings from the same flow meter will be compared at regular intervals to look for any change in performance of the system. Flow range (Turndown ratio) A turbine flow meter has a minimum and a maximum calibrated flow which together describe the range of flows that can be accurately measured. Through the addition of signal conditioning either mounted on the flow meter or built into the readout, the flow range of our flow meters has been extended considerably compared to other models on the market; the ratio of the maximum to the minimum calibrated flow (turndown ratio) is between and 0 across all models. Particular effort has been made to extend the flow range by calibrating down to lower flows enabling one flow meter to be used where two may have been required in the past. This makes the flow meter both a more economical and easier to install solution. Calibration All flow meters are calibrated at a mean viscosity of cst using ISO hydraulic mineral oil to ISO8 category HM. Special calibration is available over a custom flow range or at a different viscosity, please contact sales to discuss your application. Recommended period between calibrations is months. Maximum period between calibrations is 6 months. Unit accuracy may be affected by operating cycle, fluid condition or extended periods between recalibrations. Fluid viscosity The performance of a turbine flow meter can be affected by the viscosity of the fluid measured. The kinematic viscosity of all hydraulic fluids is related to the fluid temperature and the table below shows the affect of temperature on the kinematic viscosity of a range of typical grades of hydraulic oil. The shaded area of the table shows the range of viscosities that can be measured by a flow meter with standard calibration with minimal effect on the accuracy (less that ± % FS). Flow meters can be specially calibrated at a different viscosity to the standard or we can advise on the expected error when the flow meter is used at other viscosities, please contact sales for further information. Table showing kinematic viscosity (cst) of different mineral oils at specific temperatures Temp C ISO ISO Fluid type ISO ISO7 ISO6 ISO68 0 8.9 6.6 09. 9.9 7.6 89. 0 9.0 87.0 0.8 0.7.9 9. 0 0. 0. 8. 0. 7.9 96. 0 0..6 8.8 9.8 7. 07.7 0.0.0.0 6.6.9 6.9 0 0..7 0.8.9 9. 0. 60 7.7 0.7.7 6. 0. 7. 70 6.0 8. 0.9.0.6 9. 80.8 6. 8. 9... 90.0. 6.6 7. 8.7. 00... 6.0 7. 8.9 ISO,,, 6 and 68 based on typical figures for the Esso Nuto range of HM oils. ISO 7 based on Shell Tellus HM oil. Webtec reserve the right to make improvements and changes to the specification without notice 6 CTJ99-BU-ENG-9.pdf 0/9 (Issue.0)