Installation, Operating & Maintenance Instructions

Similar documents
Pendulum control & isolation valve with extended control range with Logic interface

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Butterfly control & isolation valve with extended control range with Logic interface

Installation, Operating & Maintenance Instructions

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

HV angle valve with single acting pneumatic actuator and closing spring (NC)

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Pendulum control & isolation valve with extended control range with RS232 interface

Pendulum control & isolation valve with RS485 interface with valve cluster functionality

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

Butterfly valve control system Series 61

Pendulum control & isolation valve with CC-Link interface

Pendulum valve control system Series 65

HV-Angle Valve (Series 264) HV-InlineValve (Series 265) with electromagnetic actuator single acting with closing spring (NC)

Control Gate Valve with stepper motor actuator

Butterfly valve control system Series 61

Pendulum valve control system Series 65

G = basic version A = with SPS H = with PFO C = with SPS and PFO. Ordering number example:

UHV Angle valve (Series 284) with pneumatic actuator, single acting with closing spring (NC)

HV Angle valve (Series 264) HV Inline valve (Series 265) with pneumatic actuator, single acting with closing spring (NC)

Rectangular Door L-VAT with pneumatic actuator double acting

Mini UHV gate valve with manual actuator with pneumatic actuator

Installation, Operating & Maintenance Instructions. Hot surfaces; do not touch!

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

HV Gate Valve with pneumatic actuator

PENDULUM CONTROL VALVE, SERIES 65.0

Gate valve control system Series 64

DRVRMDMOTL Motorized Linear Drive. DRVMDMOTLR Motorized Linear and Rotary Drive. Instruction Manual

Pendulum valve Series 16

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

Operating Instructions incl. Declaration of Conformity. Controller RVC 300 BG BE / C ( ) 1

PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves. Pressure Control Techniques. Dynamic Range

Operating Instructions. Angle Seat Control Valve. Type 7020

Compensation unit AGE-XY 50-80

INSTALLATION USER MANUAL

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

Understanding the benefits of using a digital valve controller. Mark Buzzell Business Manager, Metso Flow Control

Product Manual (Revision A, 8/2015) Original Instructions. ProAct II Digital Speed Control System. Technical Supplement

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

This manual is valid for the valve ordering numbers: E01/ E01/ E01/ E01/08

Operating Instructions

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

User Manual Solar Charge Controller 3KW

Oil-free piston compressors KK and piston vacuum pumps KV

SA Series Robot Instruction Manual

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Pressure & Vacuum Measurement. Series 356. Solutions MICRO-ION PLUS MODULES

Digital Pressure Regulator Sentronic PLUS Series 614

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

BG45 BG65S BG75 Axial Parallel Axial Parallel Axial Parallel CASM-32 (LS/BS/BN) X X CASM-40 (LS/BS/BN) X X X X CASM-63 (LS/BN/BF) X X

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

HIGH POWER SOLENOID DRIVER 1

HV gate valve with protective ring Series 17

BAS Construction Checklist

INSTALLATION and OPERATING INSTRUCTIONS

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Product Guide: Series III Pump Control Board Set (RoHS)

PRSalpha Air Drill (Double Valve)

HV gate valve Series 11

MT50 & MT150 Electrical Multi-turn Valve Actuators

Operation Manual for Torque Sensors

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA).

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

2004, 2008 Autosoft, Inc. All rights reserved.

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

WP37 & HT37 User Manual

Bowl feeder BF20 / BF25 / BF30 BF35 / BF40 / BF50

Oil Free Vacuum Pumps for Mass Spectrometry

CONTINENTAL HYDRAULICS VED03MX

Device Description User Manual Logix MD+ Positioners with HART

Valve Solutions T2B. Features & Benefits. KF50 shown (KF40, KF50, NW63, NW80 and NW100 sizes available)

Bowl Feeder BF10 / BF15 Translation of operating and installation instructions

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2

Issue 2.0 December EPAS Midi User Manual EPAS35

WPS500X. 500 psi / 34.5 bar Automotive Pressure Transducer. User s Guide

Electronic Ballast EVG 2000-T

Technical Documentation

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

User Manual. Solar Charge Controller 3KW

Spindle axis ELGC-BS-KF. Operating instructions [ ]

Directional servo-valve of 4-way design

Operators Manual. FHX Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 07/2017

PC-I 04/104. Passive PC/CAN Interface HARDWARE MANUAL ENGLISH

Rotary feed-through DDF-S/-KS

All-metal gate valve Series 48

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

Positive displacement batch controller

Hydraulic Valves «DSV»

Instruction Manual EDS-75-S EDS-100-S/F EDS-160-S/F EDS-200-S/F EDS-220-Z EDS-250-S/F

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

Rotary feed-through DDF 2

Mini slide EGSC-BS-KF. Operating instructions b [ ]

Sentronic LP IO-Link CLASS A 617 Series. 617 Series IO-Link CLASS A with Display and Controls Installation Manual

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Transcription:

Installation, Operating & Maintenance Instructions Pendulum control & isolation valve with DeviceNet interface DN 160 mm (I.D. 6") This manual is valid for the valve ordering number(s): 65044-PACQ-0002 configured with firmware 650P.1E.42 and 264420 (DeviceNet ) Sample picture 600773EA Edition 2013-02-21

Imprint Manufacturer VAT Vakuumventile AG, CH-9469 Haag, Switzerland Website: Phone: Fax: Email: www.vatvalve.com +41 81 771 61 61 +41 81 771 48 30 CH@vatvalve.com Publisher VAT Vakuumventile AG, CH-9469 Haag, Switzerland Editor VAT Vakuumventile AG, CH-9469 Haag, Switzerland Print VAT Vakuumventile AG, CH-9469 Haag, Switzerland Copyright VAT Vakuumventile AG 2013 No part of these Instructions may be reproduced in any way (photocopies, microfilms or any other reproduction processes) nor may it be manipulated with electronic systems, duplicated or distributed without written permission from VAT. Offenders are liable to pay damages. The original VAT firmware and updated state of the art versions of the VAT firmware are intended for use with VAT products. The VAT firmware contains a limited, time unlimited user license. The VAT firmware may not be used for purposes other than those intended nor is it permitted to make copies of the VAT firmware. In particular, it is strictly forbidden to give copies of the VAT firmware to other people. The use of trade names, brand names, trademarks, etc. in these Instructions does not entitle third parties to consider these names to be unprotected and to use them freely. This is in accordance with the meaning of the laws and acts covering brand names and trademarks. 2/94 Edition 2013-02-21 600773EA

Contents 1 Description of product... 5 1.1 Identification of product... 5 1.2 Use of product... 5 1.3 Used abbreviations... 5 1.4 Related documents... 5 1.5 Important information... 5 1.6 Technical data... 6 1.6.1 Control and actuating unit... 6 1.6.2 Valve unit... 7 2 Safety... 8 2.1 Compulsory reading material... 8 2.2 Danger levels... 8 2.3 Personnel qualifications... 9 2.4 Safety labels... 9 3 Design and Function... 10 3.1 Design... 10 3.2 Function... 11 3.2.1 Pressure control system overview and function... 12 3.2.2 Principle of a pressure control system... 13 4 Installation... 14 4.1 Unpacking... 14 4.2 Installation into the system... 15 4.2.1 Installation space condition... 16 4.2.2 Connection overview... 17 4.2.3 Installation procedure... 18 4.3 Tightening torque... 19 4.3.1 Mounting with centering rings... 19 4.3.2 Mounting with O-ring in grooves... 19 4.3.3 Requirements to sensor connection... 21 4.4 Electrical connection... 21 4.4.1 Ground connection... 22 4.4.2 Sensor supply concepts... 23 4.4.3 Power and sensor connection ( 15 VDC sensors) with opt. SPS module... 24 4.4.4 DeviceNet interface connection... 25 4.4.5 LOGIC I/O... 26 4.4.6 Service port connection... 27 4.5 Initial operation... 28 4.5.1 Setup procedure... 28 4.5.2 DeviceNet configuration... 29 4.5.3 LOGIC I/O configuration... 31 4.5.1 Valve configuration... 32 4.5.2 Sensor configuration... 32 4.5.3 ZERO... 33 4.5.4 LEARN... 33 4.5.5 Tuning of control performance... 35 4.6 DeviceNet interface commands... 40 4.6.1 Assembly objects... 40 4.6.2 Assembly object bit map... 41 4.6.3 Explicit messaging control commands... 43 4.6.4 Explicit messaging inquiry commands... 45 4.6.5 Explicit messaging setup commands... 51 600773EA Edition 2013-02-21 3/94

5 Operation... 56 5.1 Normal operation... 56 5.1.1 Local operation... 57 5.1.2 Remote operation... 58 5.2 Close valve... 59 5.3 Open valve... 59 5.4 Position control... 59 5.5 Pressure control... 60 5.5.1 Pressure control operation with 2 sensors... 60 5.6 Display information... 61 5.6.1 Power up... 61 5.6.2 Operation... 62 5.6.3 Errors... 62 5.6.4 Safety mode... 62 5.7 Operation during power up... 63 5.8 Behavior in case of power failure... 63 5.9 Operation under increased temperature... 64 5.10 Behavior In case of compressed air pressure drop... 64 6 Trouble shooting... 65 7 Maintenance... 68 7.1 Maintenance intervals... 68 7.2 Maintenance procedures... 69 7.2.1 Replacement of isolation seals and cleaning... 70 7.2.2 Replacement of actuator shaft seals... 73 7.2.3 Replacement of Option board... 78 8 Repairs... 84 9 Dismounting and Storage... 85 9.1 Dismounting... 85 9.2 Storage... 86 10 Packaging and Transport... 87 10.1 Packaging... 87 10.2 Transport... 88 11 Disposal... 89 12 Spare parts... 90 12.1 Drawing... 90 12.1.1 Valve unit with seals and grease... 91 12.1.2 Control and actuating unit... 91 12.1.3 Accessories... 92 13 Appendix... 93 4/94 Edition 2013-02-21 600773EA

DESCRIPTION OF PRODUCT 1 Description of product 1.1 Identification of product The fabrication number and order number are fixed on the product directly or by means of an identification plate. made in Switzerland Fabrication No.: 000.. -.... -.... /.... A -...... Fabrication number Order number 1.2 Use of product This product is a throttling pendulum valve with isolation functionality. It is intended to use for downstream pressure control applications. Use product for clean and dry vacuum applications only. Other applications are only allowed with the written permission of VAT. 1.3 Used abbreviations Abbreviation CPA CV PFO SFS SPS ADC Description Control Performance Analyzer Control View Power Failure Option Sensor Full Scale Sensor Power Supply Analog-to-digital converter 1.4 Related documents Product Data Sheet Dimensional Drawing IOMI Heating device (if valve with heater) 1.5 Important information This symbol points to a very important statement that requires particular attention. Example: Refer to chapter: «Technical data» for detailed information. 600773EA Edition 2013-02-21 5/94

DESCRIPTION OF PRODUCT 1.6 Technical data 1.6.1 Control and actuating unit Data Input voltage 1) +24 VDC (±10%) @ 0.5 V pk-pk max. [connector: POWER] Power consumption 96 W [connector: POWER] Power input (DeviceNet ) 3 W max. (from DeviceNet ) [DeviceNet connector] Sensor power supply output 2) ±15 VDC (±5%) / 1000 ma max. [connector: SENSOR] Sensor input Signal input voltage / Input resistance ADC resolution Sampling time PFO 3) battery pack Charging time Durability Compressed air supply Ambient temperature Pressure control accuracy Position resolution / position control capability Closing time throttling only Opening time throttling only Closing time throttling & isolation Opening time throttling & isolation 0-10 VDC / Ri>100 kω (linear to pressure) 0.23 mv 10 ms 2 minutes max. up to 10 years @ 25 C ambient refer to «Durability of power fail battery» for details 4-7 bar / 55-100 psi (above ATM) 0 C to +50 C max. (<35 C recommended) 5 mv or 0.1% of setpoint, whichever is greater 11111 (full stroke) 0.8 s typ. 0.8 s typ. 3 s typ. 4 s typ. [connector: SENSOR] 1) Internal overcurrent protection by a PTC device. 2) Refer to chapter «Sensor supply concepts» for details. PFO = Power Failure Option. Refer to «Behavior in case of power failure» for details. 6/94 Edition 2013-02-21 600773EA

DESCRIPTION OF PRODUCT 1.6.2 Valve unit Description Pressure range at 20 C Leak rate to outside at 20 C Leak rate valve seat at 20 C Cycles until first service - Isolation cycles (open - closed - open) - Throttling cycles (open - max. throttle - open) Admissible operating temperature Mounting position 1 10E-8 mbar to 1.2 bar (abs) 1 10E-9 mbar l/s 1 x 10E-9 mbar l/s 200 000 (unheated and under clean conditions) 1 000 000 (unheated and under clean conditions) +10 C to +120 C any (valve seat on chamber side is recommended) Wetted materials body Aluminium AA6082 (3.2315) pendulum plate Aluminium AA6082 (3.2315) sealing ring Aluminium AA6082 (3.2315) 3.2315 (AA6082), 1.4306 (304L) Other parts Stainless steel 316L (1.4404 or 1.4435), 1.4122, 301 (1.4310), 304 (1.4303), 1.4571, A2 (304) Seals body FKM e.g. Viton plate rotary feed through atmosphere side rotary feed through vacuum side shaft feed through atmosphere side shaft feed through vacuum side bonnet Max. differential pressure on plate during isolation Max. differential pressure on plate during opening and throttling Min. controllable conductance (N 2 molecular flow) Dimensions FKM e.g. Viton FKM e.g. Viton FKM e.g. Viton FKM e.g. Viton FKM e.g. Viton FKM e.g. Viton 1200 mbar in either direction 10 mbar 5 l/s Refer to dimensional drawing of specific valve ordering number (available on request) 600773EA Edition 2013-02-21 7/94

SAFETY 2 Safety 2.1 Compulsory reading material Read this chapter prior to performing any work with or on the product. It contains important information that is significant for your own personal safety. This chapter must have been read and understood by all persons who perform any kind of work with or on the product during any stage of its serviceable life. Lack of knowledge NOTICE Failing to read this manual may result in property damage. Firstly, read manual. These Installation, Operating & Maintenance Instructions are an integral part of a comprehensive documentation belonging to a complete technical system. They must be stored together with the other documentation and accessible for anybody who is authorized to work with the system at any time. 2.2 Danger levels High risk DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Medium risk WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Low risk CAUTION Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. Command NOTICE Indicates a hazardous situation which, if not avoided, may result in property damage. 8/94 Edition 2013-02-21 600773EA

SAFETY 2.3 Personnel qualifications WARNING Unqualified personnel Inappropriate handling may cause serious injury or property damage. Only qualified personnel are allowed to carry out the described work. 2.4 Safety labels Label Part No. Location on valve T-9001-156 On protective foil covering of valve opening 600773EA Edition 2013-02-21 9/94

DESIGN AND FUNCTION 3 Design and Function 3.1 Design 1 2 3 4 9 8 7 5 6 1 Plate seal 6 Integrated controller 2 Body seal 7 Rotary feed through seals 3 Shaft feed through seals 8 Pendulum plate 4 Bonnet seal 9 Sealing ring 5 Actuator 10/94 Edition 2013-02-21 600773EA

DESIGN AND FUNCTION 3.2 Function The valve plate acts, due to its pendulum motion, as a throttling element and varies the conductance of the valve opening. The integrated controller calculates the required plate position to achieve the set point pressure. Actuation is performed by a stepper motor. An encoder monitors the position. This principle ensures fast and accurate process pressure control. For opening or control the sealing ring is lifted pneumatically by compressed air, afterwards the pendulum plate moves to open or do pressure control. For leak tight closing, the sealing ring moves downwards and press the pendulum plate to valve body for isolation. Closing is performed by springs. compressed air open / pressure control sealing ring pendulum plate springs isolation close sealing ring pendulum plate 600773EA Edition 2013-02-21 11/94

DESIGN AND FUNCTION 3.2.1 Pressure control system overview and function Vacuum pressures are always absolute pressures unless explicitly specified as pressure differences. 1 Valve Q 3 2 Process chamber 3 Gas inlet p V 4 4 Pressure sensor(s) 5 Sensor cable 2 Seff 5 6 Controller and actuator 7 Cable to remote control unit 8 Cable to power supply 9 HV Pump 1 M 6 7 8 S eff Q / p S eff effective pump speed (ls -1 ) Q Gas flow (mbar) p Pressure (mbar) 9 Example: Downstream control or units used in USA S eff = 12.7 Q / p S eff effective pump speed (ls -1 ) Q Gas flow (sccm) p Pressure (mtorr) 12/94 Edition 2013-02-21 600773EA

DESIGN AND FUNCTION 3.2.1.1 Way of operation The controller compares the actual pressure in the process chamber given by the pressure sensor with the preset pressure. The controller uses the difference between actual and set pressure to calculate the correct position of the control valve. The controller drives the control valve into the correct position and the actual pressure again equals the set pressure. This control operation is performed continuously. Pressure changes in the process chamber due to leaks, desorption, and gas flow, reaction products, variations in pumping speed etc. are always corrected at once. 3.2.1.2 Pressure control In a vacuum system which is pumped and into which gas is admitted at the same time, the pressure can be controlled in two ways: 1. Downstream control (standard): The pressure is controlled by changing the conductance of a control valve between pump and process chamber. This changes the effective pumping speed at the process chamber. Pressure and gas flow can be independently controlled over a wide range. 2. Upstream control: The pressure is controlled by changing the gas flow into the process chamber, while the pumping speed remains constant. 3.2.1.3 Adaptive controller (standard) A controller adapting itself to changes in pressure, gas flow and pumping speed without any manual adjustments. This allows for a completely automatic operation of the system. 3.2.2 Principle of a pressure control system 2. 1. Host computer sends pressure set point 2. Controller reads actual pressure from sensor 1. 3. 4. 3. Optimizing module sends new PID parameters 4. Actuator sets new valve position Host computer (Example) 600773EA Edition 2013-02-21 13/94

INSTALLATION 4 Installation WARNING Unqualified personnel Inappropriate handling may cause serious injury or property damage. Only qualified personnel are allowed to carry out the described work. 4.1 Unpacking NOTICE Physical overstraining at controller Inappropriate handling with the valve may cause in damage of controller. Do not place the valve on the controller. CAUTION Valve is a heavy component Physical overstraining. Use a crane to lift valves DN 200 (8 ) and larger. Make sure that the supplied products are in accordance with your order. Inspect the quality of the supplied products visually. If it does not meet your requirements, please contact VAT immediately. Store the original packaging material. It may be useful if products must be returned to VAT. 1. Open the transport case and remove inside packing material as far as necessary. 2. Attach lifting device for valves DN 200 (8 ) and larger. For attachment refer to dimensional drawing of valve. 3. Lift the valve carefully and place it on a clean place. Do not remove protective foils from valve opening 14/94 Edition 2013-02-21 600773EA

INSTALLATION 4.2 Installation into the system Valve opening Risk of serious injury. WARNING Human body parts must be kept out of the valve opening and away from moving parts. Do not connect the controller to power before the valve is installed complete into the system. Valve in open position WARNING Risk of injury when compressed air is connected to the valve. Connect compressed air only when: valve is installed in the vacuum system moving parts cannot be touched Sealing surfaces NOTICE Sealing surfaces of valve and vacuum system could be damage in case of incorrect handling. Only qualified personal are allowed to install the valve into the vacuum system. Wrong connection NOTICE Wrong connection may result in damage of controller or power supply. Connect all cables exactly as shown in the following descriptions and schematics. Burned connector pins (spark) NOTICE Connector pins or electronic parts could damage, if plugged and unplugged under power. Do not plug or unplug connectors under power. Contamination NOTICE Gate and other parts of the valve must be protected from contamination. Always wear clean room gloves when handling the valve. 600773EA Edition 2013-02-21 15/94

INSTALLATION Mount valve to a clean system only. 4.2.1 Installation space condition Install the valve with integrated controller with space for dismantling and air circulation as shown in figure below. 100 mm 50 mm 16/94 Edition 2013-02-21 600773EA

INSTALLATION 4.2.2 Connection overview System: 1 Valve 3 2 Process chamber 3 Gas inlet 2 4 4 Pressure sensor(s) 5 Sensor cable(s) 6 Controller and actuator 5 7 Cable to remote control unit 8 Cable to power supply 1 M 6 7 8 9 Pump 9 Controller: Ground connection DeviceNet Interface connector 600773EA Edition 2013-02-21 17/94

INSTALLATION 4.2.3 Installation procedure 1. Install valve [1] into the vacuum system. Valve seat side should face process chamber. The valve seat side is indicated by the symbol " " on the valve flange. Do not tighten the flange screws stronger than indicated under «Tightening torque». Do not admit higher forces to the valve than indicated under «Admissible forces». Make sure that enough space is kept free to do preventive maintenance work. The required space is indicated on the dimensional drawing. 2. Connect compressed air supply to connection labeled IN located at actuator, see Figure 1 below. Connect compressed air return line connection labeled OUT located at actuator, see Figure 1 below. Compressed air pressure must be in the range of: 4-7 bar / 55-100 psi (above ATM). Use only clean, dry or slightly oiled air. IN / OUT connections are 1/8 ISO/NPT internal threads. 3. Install the ground connection cable at controller. Refer to «Electrical connection» 4. Install pressure sensor(s) [4] according to the recommendations of the sensor manufacturer and directives given under «Requirements to sensor connection». 5. Connect sensor cable [5] to sensor(s) and then to valve (connector: SENSOR). Refer to chapter «Electrical connection» for correct wiring. 65044-PACQ-0002 supports 2 sensor(s). 6. Connect valve to DeviceNet [7] (connector: INTERFACE). Refer to «DeviceNet schematics» for correct wiring. 7. Connect power supply [8] to valve (connector: POWER). Refer to chapter «Electrical connection» for correct wiring. To provide power to the valve motor pins 4 and 8 must be bridged, otherwise motor interlock is active and the valve enters the safety mode and is not operative. Refer also to «Safety mode». 8. This valve has a double sealed rotary feedthrough and optionally an intermediate pumping port for the actuator shaft. This port (1/8 ISO/NPT) could be connected to the vacuum line, see Figure 2 below. 9. This valve may optionally be equipped with a heating device. Connect VAT heating device according to manual of respective heating device. 10. Perform «Setup procedure» to prepare valve for operation. Without performing the setup procedure the valve will not be able to do pressure control. OUT IN intermediate pumping port Fig. 1 Fig. 2 18/94 Edition 2013-02-21 600773EA

INSTALLATION 4.3 Tightening torque The torque values below are dependent on many factors, such as materials involved, surface quality, surface treatment, and lubrication. The torques below are valid if immersion depth of the mounting screws is at least once the thread diameter (min. 1d), and the friction coefficient of the screw-flange connection ( total = ( screw thread-helicoil + under screw head)/2) is bigger than 0.12. Lower friction coefficients may damage the valve, as the resulting preload force gets too high. Therefore for other friction coefficients the torque needs to be adapted. Please review design guidelines for Helicoil-Screw connections and make sure that screws in use are capable to withstand applied torques, are appropriate for the application and are not too long. Too long screws may damage the valve, the immersion depth should not exceed (hole depth 1 mm). Tighten mounting screws of the flanges uniformly in crosswise order. Observe the maximum torque levels in the following tables. 4.3.1 Mounting with centering rings ISO-F max. tightening torque (Nm) ISO-F max. tightening torque (lbs. ft) 13-15 9-11 hole depth (mm) hole depth (inch) 14 0.55 Refer to «Spare parts / Accessories» for centering rings ordering numbers. 4.3.2 Mounting with O-ring in grooves ISO-F JIS ASA-LP ISO-F JIS ASA-LP max. tightening torque (Nm) max. tightening torque (lbs. ft) 35-40 35-40 35-40 26-30 26-30 26-30 hole depth (mm) hole depth (inch) 14 0.55 600773EA Edition 2013-02-21 19/94

INSTALLATION Force at valve body NOTICE Forces from evacuating the system, from the weight of other components, and from baking can lead to deformation and malfunctioning of the valve. Do not higher force the valve body as specified. The following forces are admissible. Axial tensile or compressive force «F A» Bending moment «M» N lb. Nm lbf. M 2000 440 80 60 F A For a combination of both forces (F A and M) the values are invalid. Verify that the depth of the mounting screws is min. 1 x thread diameter. Please contact VAT for more information. 20/94 Edition 2013-02-21 600773EA

INSTALLATION 4.3.3 Requirements to sensor connection To achieve fast and accurate pressure control a fast sensor response is required. Sensor response time: < 50ms. The sensor is normally connected to the chamber by a pipe. To maintain that the response time is not degraded by this connection it needs to meet the following requirements: Inner diameter of connection pipe: > = 10 mm Length of connection pipe: < = 300 mm These conductance guidelines must include all valves and limiting orifices that may also be present. Make also sure that there is no obstruction in front of sensor connection port inside the chamber. The sensor should also be mounted free of mechanical shock and vibration. Dynamic stray magnetic fields may introduce noise to sensor output and should be avoided or shielded. Pressure Sensor L1 min. 10 mm L2 min. 10 mm Process Chamber L1 + L2 < = 300 mm Isolation Valve (optional) 4.4 Electrical connection Wrong connection NOTICE Wrong connection may result in damage of controller or power supply. Connect all cables exactly as shown in the following descriptions and schematics. Burned connector pins (spark) NOTICE Connector pins or electronic parts could damage, if plugged and unplugged under power. Do not plug or unplug connectors under power. 600773EA Edition 2013-02-21 21/94

INSTALLATION 4.4.1 Ground connection Recommendation for ground strap between controller ground and system chassis. Material L (Length max.) B1 (min.) B2 (min.) d1 ( ) d2 ( ) copper tinned 200 mm 25 mm 25 mm 4.5 mm customized Recommended torque: 1,3 1,7Nm B2 L System Ground strap PE B1 d1 d2 Ground connection Chassis (PE) (Protective Earth) Connection plates of ground strap must be total plane for a good electrical contact! The connection point at chassis (FE) must be blank metal (not coated). It is also possible to connect the ground strap at system chamber if it is well connected to PE. Avoid low chassis cross section to the system PE connection. (min. same cross section as ground strap) 22/94 Edition 2013-02-21 600773EA

INSTALLATION 4.4.2 Sensor supply concepts This valve offers 3 alternative concepts to supply the sensor(s) with power. This depends on the sensor type and valve version that is used. This valve is available with an optional sensor power supply module (SPS) that converts 15 VDC from the 24 VDC. Concepts: External +24 VDC supplied to POWER connector is feedthrough to SENSOR connector to supply 24 VDC sensors. Refer to chapter «Power and sensor connection (+24 VDC sensors)» for schematic and correct wiring. External 15 VDC supplied to POWER connector is feedthrough to SENSOR connector to supply 15 VDC sensors. Refer to chapter «Power and sensor connection ( 15 VDC sensors) without optional SPS module» for schematic and correct wiring. External +24 VDC supplied to POWER connector is converted into 15 VDC by the valve internal SPS and supplied to SENSOR connector to supply 15 VDC sensors. Refer to chapter «Power and sensor connection ( 15 VDC sensors) with optional SPS module» for schematic and correct wiring. This concept is only possible when SPS retrofit is installed. Valve versions: 650.. -.. G. -.... and 650.. -.. H. -.... SPS module not included 650.. -.. A. -.... and 650.. -.. C. -.... SPS module included The SPS module can be retrofitted. Refer to chapter «Retrofit / replacement procedure» for instruction. 600773EA Edition 2013-02-21 23/94

INSTALLATION 4.4.3 Power and sensor connection ( 15 VDC sensors) with opt. SPS module [650.. -.. A. -.... / 650.. -.. C. -.... versions recommended] 4.4.3.1 Sensor power wiring via controller Pins 4 and 8 must be bridged for operation. An optional switch would allow for motor interlock to prevent valve from moving. Low range sensor may be connected to sensor 1 or sensor 2 input. Do configuration accordingly. Use shielded sensor cable(s). Keep cable as short as possible, but locate it away from noise sources. Connect Power supply (+24 / GND) at DB 9 male power connector and Sensors (+15V -15V / 0V / + / -) at DB 15 female sensor connector exactly as shown in the drawing above! Connector: Use only screws with 4 40 UNC thread for fastening the connectors! 24/94 Edition 2013-02-21 600773EA

INSTALLATION 4.4.4 DeviceNet interface connection Connector type: Micro-style male (5 pin), connector is shown on panel refer to chapter «Installation into the system». At valve controller DeviceNet cable PIN Name Wire color Description 1 Drain Bare Shield 2 V+ Red DeviceNet power supply + 3 V- Black DeviceNet power supply - 4 CAN_H White DeviceNet signal 5 CAN_L Blue DeviceNet signal The DeviceNet interface is galvanic isolated from control unit. 4.4.4.1 Micro Connector Pinout Male (pins) at valve controller Female (sockets) at DeviceNet cable 4 1 5 3 2 3 4 5 2 1 600773EA Edition 2013-02-21 25/94

INSTALLATION 4.4.5 LOGIC I/O This interface allows for remote operation by means of a command set based on the DeviceNet protocol. In addition there is a digital input and a digital output. Digital input may only be operated by a switch. Active digital input has: higher priority than DeviceNet commands higher priority than Local commands Configuration with switch for digital input: Do not connect other pins than indicated in the schematics above! Connector type: Binder M8 (99-3363-00-04). 26/94 Edition 2013-02-21 600773EA

INSTALLATION 4.4.5.1 Digital input Pin Signal type Description 3 Digital input This function will close the valve. Valve will be in interlock mode as long as function is activated. After deactivation of function it will remain effective until - converse DeviceNet control command have been received The function is activated when optocoupler is on in non inverted configuration. The function is activated when optocoupler is off in inverted configuration. Configuration can be adjusted in local operation via service port with CV, CPA or Hyper terminal. Refer to chapter: «LOGIC I/O configuration». 1 Digital ground Ground for digital input. Connect switch to ground. See also chapter:. The digital input is digitally filtered. Filter delay is 50ms. This means that digital signal must be applied for at least 50ms to be effective. Refer to chapter: «0 LOGIC I/O» for details about input circuit. 4.4.5.2 Digital output Pin Signal type Description 2 Digital output This function will indicate that the valve is closed. If the function ON is configured the output is continous on. Configuration can be changed in local operation via service port with CV, CPA or Hyper terminal. Refer to chapter: «LOGIC I/O configuration». 4 Digital common Common for all digital output. Connect + or terminal of source with common. See also chapter: «LOGIC I/O». 4.4.6 Service port connection The service port (connector: SERVICE) allows to connect the valve to a RS232 port of a computer. This requires a service cable and software from VAT. You can use our Software (freeware) 'Control Performance Analyzer' which can be downloaded from: http://www.vatvalve.com/customer-service/informations-and-downloads/control-performance-analyzer. Alternatively the VAT Service Box2 can be connected to the service port for setup and local operation. The service port is not galvanic isolated. Therefore we recommend using this only for setup, testing and maintenance and not for permanent control. Refer also to chapter: «Local Operation» for details and to chapter «Spare parts / Accessories» for ordering numbers of service cable, software and Service Box 2. Use only screws with 4 40 UNC thread for fastening the service port connector. 600773EA Edition 2013-02-21 27/94

INSTALLATION 4.5 Initial operation 4.5.1 Setup procedure To enable the valve cluster for pressure control setup steps 1 to 6 must be performed. In case position control is required only it s sufficient to perform steps 1 to 4. Setup step 1 Power up 2 3 4 DeviceNet configuration Valve configuration Sensor configuration 5 ZERO 6 LEARN Description Turn on external + 24VDC power supply of valve (and external 15 VDC for sensor power supply if required). Refer to chapter «Behavior during power up» for details. DeviceNet node number and baudrate for valve must be selected. DeviceNet parameters must be adapted according to application needs. Refer to chapter «DeviceNet configuration» for details. Basic configurations of valve must be adapted according to application needs. Refer to chapter «Valve configuration» for details. Basic configurations of sensor(s) must be adapted according to application needs. Refer to chapter «Sensor configuration» for details. Compensation of the sensor offset voltage. Refer to chapter «ZERO» for details. Determination of the vacuum system characteristic to accommodate the PID controller. Refer to chapter «LEARN» for details. Without LEARN the valve is not able to run pressure control. 28/94 Edition 2013-02-21 600773EA

INSTALLATION 4.5.2 DeviceNet configuration MSD and LSD switches are arranged in unusal order. Make sure to select the correct node number. DeviceNet node number and baudrate for valve must be selected. DeviceNet parameters must be adapted according to application needs. It s not the goal of this manual to describe the configuration of all parameters. Several tools and interfaces from different vendors are on the market. For communication structure and way of commanding with these tools and interfaces you need to consult the vendor. Operation via DeviceNet is sophisticated and requires specific knowledge and training about it and its tools. VAT offers valve-related but not general DeviceNet support. Contact us under: devicenetsupport@vat.ch 1. The node number is the device address and can be selected by two rotary switches which are on the panel. Set the most significant digit (MSD) with the middle switch and the least significant digit (LSD) with the left switch. For example, to set the address to 13, set the MSD to 1 and the LSD to 3. (Factory default is 00). In case a valid node number (0-63) is selected the number will be used at start of system as MAC-Id of the device and stored in the device memory. In this case node number is not selectable by DeviceNet service. If an invalid node number is selected (> 63) node number will be read from the device memory and node number is settable by DeviceNet. with these tools and interfaces you need to consult the vendor. 2. The baudrate can be selected by a rotary switch which is also on the panel. If a valid baudrate is selected (125kBaud, 250kBaud, 500kBaud), the rate will be used and stored in the device memory as actual baudrate (Factory default is 500kb). In this case baudrate is not selectable by DeviceNet service. If an invalid baudrate is selected, the baudrate will be read from the device memory and the rate is settable by DeviceNet. 3. Pressure range for DeviceNet communication must be selected. Default is 0-10 000. Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Note: It s not possible to do pressure value range configuration in local operation. Remote operation: (Refer to chapter «Explicit messaging setup commands» for details) 1. Select DATA TYPE 2. Select GAIN 4. DeviceNet offers many parameters that may be set. Many of them are not directly used to operate the valve but are part of the DeviceNet profile. You may set all parameters via electronic data sheet (EDS) or via explicit messaging. Setup steps 3 to 5 describe all valve specific parameters that require a setup to enable for valve operation. The Electronic Data Sheet (EDS) allows the configuration of DeviceNet components with a general configuration tool. The EDS contains general data regarding device, selection of operation mode, 600773EA Edition 2013-02-21 29/94

INSTALLATION assignment of I/O data to the corresponding I/O message connections (Polling, Bit Strobe, Change of State) and description of device parameters. The parameters of a device are described in a form which is defined by DeviceNet and visualized by a configuration tool. 5. If Poll or Change of State / Cycling connection is used for remote operation it s required to preset the correct assemblies. Default values are: poll output assembly = 8, poll input assembly = 3, change of state / cycling input assembly = 3 Assembly object change procedure: Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Note: It s not possible to make assembly object configuration in local operation. Remote operation: (Refer to chapter «Explicit messaging setup commands» for details) 1. Select POLL CONNECTION OUTPUT assembly 2. Select POLL CONNECTION INPUT assembly 3. Select CHANGE OF STATE / CYCLING INPUT assembly 4. Reestablish poll I/O connection 30/94 Edition 2013-02-21 600773EA

INSTALLATION 4.5.3 LOGIC I/O configuration Default configuration for LOGIC I/O is: # Function Mode Input Digital input close valve non inverted enabled # Function Mode Output Digital output close non inverted enabled The «LOGIC I/O» Digital input and Digital output can be adjusted. Local operation: ( Control View, Control Performance Analyzer or Hyper terminal) 1. Open CV or CPA 2. Switch to [LOCAL] 3. Go to «Tools» > «Terminal» and send setup command according to application needs. (possibility of adjustment see below) For Digital input: to change the configuration: s:2601abcdef[cr] to read the configuration: i:2601[cr] Each element is separated with square brackets for clarity. Square brackets are not part of command syntax. All elements are ASCII characters. There are no spaces between the elements necessary. Command is case sensitive. Remote operation: data length 6 characters a b c def 0 = close valve 1 = open valve 0 = non inverted 1 = inverted 0 = enabled 1 = disabled 000 (reserved) It s not possible to configuration in remote operation. For Digital output: to change the configuration: s:2611abcdef[cr] to read the configuration: i:2611[cr] data length 6 characters a 0 = close 1 = open 2 = On b c def 0 = non inverted 1 = inverted 0 = enabled 1 = disabled 000 (reserved) For LOGIC I/O connector schematics see also chapter «LOGIC I/O». 600773EA Edition 2013-02-21 31/94

INSTALLATION 4.5.1 Valve configuration Basic valve configuration must be adapted according to application needs. Definition of valve plate position in case of: After power up, default is close. Power failure, default is close. Only for versions that have Power Fail Option equipped [650.. -.. C. -.... or 650.. -.. H. -.... ]. Network failure, default setting refer to individual product data sheet. Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) 1. Do power up configuration in menu Setup / Valve. 2. Do power fail configuration in menu Setup / Valve. Remote operation: (Refer to chapter «Explicit messaging setup commands» for details) 1. Select POWER UP CONFIGURATION 2. Select POWER FAIL CONFIGURATION 4.5.2 Sensor configuration Basic sensor configuration must be adapted according to application needs. ZERO function: This may be disabled or enabled. Default is enabled. Refer also to chapter «ZERO». Sensor configuration for 2 sensors version [650.. -... P -....]. Refer also to «Pressure control operation with 2 sensors». Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) 1. Enable or disable ZERO function in menu Setup / Sensor. 2. Do 2 sensors configuration in menu Setup / Sensor. Remote operation: (Refer to chapter «Explicit messaging setup commands» for details) 1. Select ZERO CONTROL 2. Select SENSOR MODE 3. Select SENSOR RATIO 32/94 Edition 2013-02-21 600773EA

INSTALLATION 4.5.3 ZERO ZERO allows for the compensation of the sensor offset voltage. When ZERO is performed the current value at the sensor input is equated to pressure zero. In case of a 2 sensor system both sensor inputs will be adjusted. A max. offset voltage of +/- 1.4 V can be compensated. The offset value can be read via local and remote operation. Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Go to menu Zero / ZERO and follow instructions. Remote operation: (Refer to chapter «Explicit messaging control commands» resp. «Explicit messaging setup commands» for details) 1. Send EXECUTING (if not yet selected) 2. Select SETPOINT TYPE = position control 3. Select CONTROL MODE for position = open valve 4. Wait until process chamber is evacuated and sensor signal is not shifting anymore. 5. Send ZERO Do not perform ZERO as long as pressure gauge voltage is shifting otherwise incorrect pressure reading is the result. Refer to manual of sensor manufacturer for warm up time. Do not perform ZERO, if the base pressure of your vacuum system is higher than 1 of sensor full scale. We recommend disabling ZERO function in this case; refer to «Valve and sensor configuration» of the setup procedure. Otherwise incorrect pressure reading is the result. 4.5.4 LEARN LEARN adapts the PID controller of the valve to the vacuum system and its operating conditions. LEARN must be executed only once during system setup. The LEARN routine determines the characteristic of the vacuum system. Based on this, the PID controller is able to run fast and accurate pressure control cycles. This characteristic depends on various parameters such as chamber volume, conductance and flow regime. Therefore it must be performed with a specific gas flow according to instruction below. The result of LEARN is a pressure versus valve position data table. This table is used to adapt the PID parameters. The data table is stored in the device memory which is power fail save. The data table can be up-/downloaded via Control Performance Analyzer software or remote interface. Due to encoding the data may not be interpreted directly. By an OPEN VALVE, CLOSE VALVE, POSITION CONTROL or PRESSURE CONTROL command the routine will be interrupted. 600773EA Edition 2013-02-21 33/94

INSTALLATION Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Go to Learn / LEARN menu and follow instructions. Note: Gasflow calculation according to recommendation below is done automatically based on inputs. Remote operation: (Refer to chapter «Explicit messaging control commands» resp. «Explicit messaging setup commands» for details) 1. Send EXECUTING (if not yet selected) 2. Select SETPOINT TYPE = position control 3. Select MODE for position = open valve 4. Set specific gas flow according to calculation below and wait until flow is stable. Autolearn does not need to be performed with the process gas. Instead N 2 or Ar may be used. 5. Set LEARN PRESSURE LIMIT to full scale 6. Send LEARN Sensor signal must not shift during LEARN. Wait until sensor signal is stable before LEARN is performed. Learn may take several minutes. Do not interrupt the routine as a single full run is required to ensure fast and accurate pressure control. The PID controller covers 5% to 5000% of the gas flow which was used for learn. Gasflow calculation for LEARN: Do not apply a different gasflow for learn than determined below. Otherwise pressure control performance may be insufficient. Required pressure / flow regime must be known to calculate the most suitable learn gas flow for a specific application. Choose the applicable formula depending on units you are familiar with. q L = p SFS 2000 C min q L gasflow for learn [Pa m 3 /s] p SFS sensor full scale pressure [Pa] C min min. controllable conductance of valve [l/s] (refer to «Technical data») q L = p SFS 2 C min q L gasflow for learn [mbar l/s] p SFS sensor full scale pressure [mbar] C min min. controllable conductance of valve [l/s] (refer to «Technical data») q L = 39.4 p SFS C min q L gasflow for learn [sccm] p SFS sensor full scale pressure [Torr] C min min. controllable conductance of valve [l/s] (refer to «Technical data») 34/94 Edition 2013-02-21 600773EA

INSTALLATION 4.5.5 Tuning of control performance Normally the default settings will result in good pressure control performance. For some applications tuning may be required to improve performance. The tuning procedures for each parameter (grey boxes) and its default values are described separately below. Strictly keep the procedure order. Start Set all paramters to default Pressure control ok? No Reset gain factor to 1.0 Gain factor adjustment Sensor delay adjustment Setpoint ramp adjustment Valve speed adjustment Gain factor adjustment Pressure control ok? No Pressure control ok? No Pressure control ok? No Pressure control ok? No End Contact VAT Required information for support: Go to Tools / Create Diagnostic File in Control View resp. Control Performance Analyzer and save file Pressure / flow / gas conditions to be controlled Chamber volume Pumping speed (l/s) and pump type (e.g. turbo pump) System description Problem description Send diagnostic file with and all required information to tuning-support@vat.ch 600773EA Edition 2013-02-21 35/94

INSTALLATION 4.5.5.1 Gain factor adjustment The gain factor effects: Stability, Response time Default value is 1. Adjustment range is from 0.0001 to 7.5. Higher gain results in: faster response higher over- / undershoot of pressure Lower gain results in: slower response lower over- / undershoot of pressure Adjustment procedure: 1. Start with gain factor 1.0 2. Open valve. 3. Control a typical pressure / flow situation. 4. Repeat from step 2 with lower (higher) gain factors until optimal pressure response is achieved and stability is ok. Normally adjustments down to gain factors of 0.42 should lead to good results. Otherwise you may need to improve sensor connection. Refer to «Requirements to sensor connection». Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Set gain factor in menu Setup / Control Parameter Remote operation: (Refer to chapter «Explicit messaging setup commands» for details) Send PID CONTROLLER CONFIGURATION GAIN FACTOR 36/94 Edition 2013-02-21 600773EA

INSTALLATION 4.5.5.2 Sensor delay adjustment Sensor delay adjustment effects: Stability Default value is 0. Adjustment range is from 0 to 1.0s. Pipes and orifices for sensor attachment delay response time and so badly impact pressure control stability. By adapting this parameter to the approximate delay time stability problems can be reduced. But control response time will be slowed down by this measure. Adjustment procedure: Whenever possible sensors should be attached to the chamber according to «Requirements to sensor connection». This is the most effective measure against stability issues. If your gauge attachment fulfills these criteria do not use this parameter. 1. Start with gain factor 1.0 and sensor delay 0s. 2. Open valve. 3. Control a typical pressure / flow situation. 4. Repeat from step 2 with higher sensor delays until best possible stability is achieved. 5. Adjustment gain factor again. Refer to «Gain factor adjustment». Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Go to Setup / Control Parameter menu. Select sensor delay. Remote operation: (Refer to chapter «Explicit messaging setup commands» for details) Send PID CONTROLLER CONFIGURATION SENSOR DELAY 600773EA Edition 2013-02-21 37/94

INSTALLATION 4.5.5.3 Setpoint ramp adjustment Setpoint ramp effects: Undershoot of pressure, Response time Default value for Setpoint Ramp is 1. Adjustment range for Setpoint Ramp is from 0 to 10 s. This parameter defines the time that is used to decrease / raise pressure between 2 setpoints. Especially in pressure decrease situations at low flows pressure response can be improved much by adapting setpoint ramp time. Pressure chart Without setpoint ramp optimizing With setpoint ramp optimizing P SFS P START P END t Choose the applicable formula depending on units you are familiar with. t = Setpoint Ramp Adjustment procedure: 1. Start with optimal gain factor and sensor delay time according to preceding tuning steps. 2. Control a typical pressure / flow situation. 3. Control a lower pressure. 4. Repeat from step 2 with longer setpoint ramps until best response is achieved. 5. Verify pressure control response for a setpoint raise situation. In case a long ramp time is required to get optimal performance for pressure decrease situations it may be of advantage to apply different settings for decrease / raise control situations. Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Go to Setup / Control Parameter menu. Select setpoint ramp. Remote operation: (Refer to chapter «Explicit messaging setup commands» for details) Send PID CONTROLLER CONFIGURATION RAMP TIME 38/94 Edition 2013-02-21 600773EA

INSTALLATION 4.5.5.4 Valve speed adjustment Valve speed effects: Response time Default value is 1000. Adjustment range is from 1 to 1000. This parameter effects valve plate actuating speed. Speed adjustment is effective for PRESSURE CONTROL and POSITION CONTROL. Adjustment procedure: Normally best pressure control response is achieved with max. valve speed. In particular applications it may be of advantage to have a slower valve response. OPEN and CLOSE are always done with maximum speed. 1. Use optimal gain factor, sensor delay time and setpoint ramp according to preceding tuning steps. 2. Open valve. 3. Control a typical pressure / flow situation. 4. Repeat from step 2 with slower valve speed until required response is achieved. Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Go to Setup / Control Parameter menu. Select valve speed. Remote operation: ((Refer to chapter «Explicit messaging setup commands» for details) Send VALVE SPEED 600773EA Edition 2013-02-21 39/94

INSTALLATION 4.6 DeviceNet interface commands 4.6.1 Assembly objects Factory default assemblies are: Input assembly 3 / Output assembly 8 Number Type Composition 2) [number of data bytes] 1) 3 Input 4 Input 5 Input 7 Output 8 Output 13 (Dh) 14 (Eh) 100 (64h) 101 (65h) 102 (66h) Input Input Input Input Output EXCEPTION STATUS PRESSURE POSITION EXCEPTION STATUS PRESSURE SETPOINT 3) EXCEPTION STATUS PRESSURE SETPOINT 3) POSITION SETPOINT 3) SETPOINT TYPE CONTROL MODE SETPOINT 3) SETPOINT TYPE EXCEPTION STATUS EXCEPTION DETAIL ALARM EXCEPTION DETAIL WARNING EXCEPTION STATUS PRESSURE POSITION VALVE CLOSED / OPEN CHECK 4) EXCEPTION STATUS PRESSURE POSITION DEVICE STATUS 2 ACCESS MODE EXCEPTION STATUS PRESSURE POSITION VALVE CLOSED / OPEN CHECK 4) DEVICE STATUS 2 CONTROL MODE SETPOINT 3) SETPOINT TYPE LEARN 5) LEARN PRESSURE LIMIT ZERO 5) [1] [2] or [4] [2] or [4] [1] [2] or [4] [2] or [4] [1] [2] or [4] [2] or [4] [2] or [4] [2] [1] [1] [2] or [4] [1] [1] [15] [15] [1] [2] or [4] [2] or [4] [1] [1] [2] or [4] [2] or [4] [1] [1] [1] [2] or [4] [2] or [4] [1] [1] [1] [2] or [4] [1] [1] [2] or [4] [1] 1) Depending on DATA TYPE configuration (signed integer or floating point) the length may vary. DATA TYPE may be changed via Explicit Messaging refer to «Explicit messaging setup commands» for details or via EDS file. 2) For data format details refer to «Explicit messaging commands». 3) PRESSURE SETPOINT or POSITION SETPOINT depending on related SETPOINT TYPE 4) 0 = Valve is neither closed nor open, 1 = Valve is CLOSED, 2 = Valve is OPEN 5) To activate ZERO or LEARN use 1 as data else 0. Apply always correct procedures as described in «ZERO (setup step 4)» or «LEARN (setup step 5)» 40/94 Edition 2013-02-21 600773EA

INSTALLATION 4.6.2 Assembly object bit map This is an example based on output assembly 8 and input assembly 3 to illustrate bit map. DATA TYPE in this example is signed integer. 4.6.2.1 Output assembly Assembly Type Byte Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 1 MODE 8 Output 2 SETPOINT low byte 3 SETPOINT high byte 4 SETPOINT TYPE CONTROL MODE may be set to one out of below selections, see also «Explicit messaging control commands»: Description Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Control valve 0 0 0 0 0 0 0 0 Close valve 0 0 0 0 0 0 0 1 Open valve 0 0 0 0 0 0 1 0 Hold valve 0 0 0 0 0 0 1 1 SETPOINT may be set to any value between the lowest and the highest value. Depending on SETPOINT TYPE it reflects position or pressure setpoint, see also «Explicit messaging control commands». Description Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 low byte 0 0 0 0 0 0 0 0 Lowest value (0) high byte 0 0 0 0 0 0 0 0 Highest value (10000) low byte 0 0 0 1 0 0 0 0 high byte 0 0 1 0 0 1 1 1 SETPOINT TYPE may be set to one out of below selections, see also «Explicit messaging control commands». Description Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Pressure control 0 0 0 0 0 0 0 0 Position control 0 0 0 0 0 0 0 1 600773EA Edition 2013-02-21 41/94

INSTALLATION 4.6.2.2 Input assembly Instance Type Byte Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 1 EXCEPTION STATUS 3 Input 2 PRESSURE low byte 3 PRESSURE high byte 4 POSITION low byte 5 POSITION high byte EXCEPTION STATUS will respond with one out of below selections, see also «Explicit messaging inquiry commands». Description Value Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Manufacturer specific alarm present 84h 1 0 0 0 0 1 0 0 Manufacturer specific warning present C0h 1 1 0 0 0 0 0 0 No warning, no error present 80h 1 0 0 0 0 0 0 0 PRESSURE will respond with any value between the lowest and the highest value, see also «Explicit messaging inquiry commands»: Description Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Lowest value low byte 00h 0 0 0 0 0 0 0 0 0 0000h high byte 00h 0 0 0 0 0 0 0 0 Highest value 10000 2710h low byte 10h 0 0 0 1 0 0 0 0 high byte 27h 0 0 1 0 0 1 1 1 POSITION will respond with any value between the lowest and the highest value, see also «Explicit messaging inquiry commands»: Description Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Lowest value low byte 00h 0 0 0 0 0 0 0 0 0 0000h high byte 00h 0 0 0 0 0 0 0 0 Highest value 10000 2710h low byte 10h 0 0 0 1 0 0 0 0 high byte 27h 0 0 1 0 0 1 1 1 42/94 Edition 2013-02-21 600773EA

INSTALLATION 4.6.3 Explicit messaging control commands Command (DeviceNet term if deviant) Service Code Class ID Instance ID Attribute ID Description Service data length (number of bytes) Service data field 6 48 1 3 This command changes the valve to executing state. EXECUTING EXECUTING must to be selected to enable for all executing commands such as control mode, close valve and open valve. If valve is already in executing state and anew EXECUTING command is sent DeviceNet will return an error message. IDLE 7 48 1 3 This command changes the valve to idle state. RESET FACTORY RESET SETPOINT TYPE CONTROL MODE 5 1 1 0 This command resets the DeviceNet interface. 5 1 1 1 This command resets the DeviceNet interface to factory default settings. All previously done configurations will be overwritten. Set 16 51 0 8 1 Y Get 14 51 0 8 1 Y: 0 pressure control 1 position control This command selects / returns current setpoint type. It toggles valve operation mode between position and pressure control. To perform either position or pressure control also correct CONTROL MODE must be selected. Set 16 51 1 (pressure) 2 (position) 5 1 Y Get 14 51 1 (pressure) 2 (position) 5 1 Y: 0 control mode (pressure resp. position control) 1 close valve (valve will close) 2 open valve (valve will open) 3 hold (stops the valve at the current position) 4 safe state (valve will close) This command preselects / returns the control mode for pressure resp. position control. By means of instance ID either pressure or position must be addressed. To activate either pressure or position control you must select correct SETPOINT TYPE separately. Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 600773EA Edition 2013-02-21 43/94

INSTALLATION Command (DeviceNet term if deviant) POSITION SETPOINT PRESSURE SETPOINT ASSEMBLY OBJECTS Service Code Class ID Instance ID Attribute ID Description Service data length (number of bytes) Service data field Set 16 51 2 6 2 or 4 Y Get 14 51 2 6 2 or 4 Y: position setpoint according to selected DATA TYPE, 0 (closed) 10 000 (open) This command transfers/reads the position setpoint to/from the valve. Set 16 51 1 6 2 or 4 Y Get 14 51 1 6 2 or 4 Y: pressure setpoint according to selected DATA TYPE, nominal pressure range is 0 10 000 (sensor full scale) but it may be scaled, refer also to command GAIN for details. This command transfers/reads the pressure setpoint to/from the valve. Set 16 4 Get 14 4 7 8 102 3 4 5 13 14 100 101 3 X Y 3 X X, Y: depending on respective assembly object, refer to «Assembly objects» for details. Instance ID = assembly object number. This command writes/reads the respective assembly object. Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 44/94 Edition 2013-02-21 600773EA

INSTALLATION 4.6.4 Explicit messaging inquiry commands Command (DeviceNet term if deviant) VALVE CLOSED CHECK (discrete input 1) VALVE OPEN CHECK (discrete input 2) Service Code Class ID Instance ID Attribute ID Description Service data length (number of bytes) Get 14 8 1 3 1 This command returns: 0 valve is not closed 1 valve is closed Get 14 8 2 3 1 This command returns: 0 valve is not open 1 valve is open Service data field POSITION PRESSURE SENSOR 1 READING SENSOR 2 READING SENSOR 1 OFFSET VALUE (Sensor 1 offset A) SENSOR 2 OFFSET VALUE (Sensor 2 offset A) Get 14 49 3 6 2 or 4 This command returns the current valve position according to selected DATA TYPE. Position range is 0 (closed) 10 000 (open). Get 14 49 1 6 2 or 4 This command returns the actual pressure according to selected DATA TYPE. Nominal pressure range is 0 10 000 (sensor full scale) but it may be scaled. Refer also to command GAIN and picture on the following page for details. Get 14 100 1 108 2 or 4 This function returns direct reading from sensor 1 according to selected DATA TYPE. Nominal range is 0 10 000 but it may be scaled. Refer also to command GAIN and picture on the following page for details. Get 14 100 1 109 2 or 4 This function returns direct reading from sensor 2 according to selected DATA TYPE. Nominal range is 0 10 000 but it may be scaled. Refer also to command GAIN and picture on the following page for details. 49 1 12 Get 14 2 or 4 100 1 110 These commands return the offset voltage (adjusted by ZERO) of the sensor 1 according to selected DATA TYPE. Both commands are identical. Value range is -1400 +1400 (-1.40V +1.40V). Get 14 100 1 111 2 or 4 This command returns the offset voltage (adjusted by ZERO) of the sensor 2 according to selected DATA TYPE. Value range is -1400 +1400 (-1.40V +1.40V). Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 600773EA Edition 2013-02-21 45/94

0-10V 0-10V INSTALLATION Example of PRESSURE and SENSOR READING allocation: High range sensor 1 Torr PRESSURE 0 10 000 SENSOR 1 READING 0 10 000 Low range sensor 100 mtorr 0 mtorr SENSOR 2 READING 0 10 000 Above picture shows a 2 sensor system. In this configuration sensor 2 covers low range (100 mtorr) and sensor 1 covers high range (1 Torr). Switchover between sensors is done automatically according to «Pressure control operation with 2 sensors». 46/94 Edition 2013-02-21 600773EA

INSTALLATION Command (DeviceNet term if deviant) LEARN STATUS (calibration state) Service Code Class ID Instance ID Attribute ID Description Service data length (number of bytes) Get 14 51 1 106 2 Service data field This command returns the status of the LEARN procedure. The status is binary coded. Bit Explanation: (LSB) 0 0 = LEARN not running 1 = LEARN running 1 0 = LEARN data set present 1 = LEARN data set not present 2 0 = ok 1 = LEARN terminated by user 3 0 = ok 1 = pressure in position OPEN > 50% sensor full scale (of high range sensor in case of a 2 sensor system) or > LEARN PRESSURE LIMIT 4 0 = ok 1 = pressure in position 0 < 10% sensor full scale (of low range sensor in case of a 2 sensor system) 5 0 = ok 1 = pressure falling during LEARN 6 0 = ok 1 = sensor not stable during LEARN 7 reserved 8 reserved 9 reserved 10 0 = ok 1 = LEARN terminated by controller 11 0 = ok 1 = pressure in position OPEN negativ 12 reserved 13 reserved 14 reserved 15 reserved (MSB) 16 reserved Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 600773EA Edition 2013-02-21 47/94

INSTALLATION Command (DeviceNet term if deviant) DEVICE STATUS 1 DEVICE STATUS 2 EXCEPTION STATUS (status) EXCEPTION DETAIL ALARM EXCEPTION DETAIL WARNING Service Code Class ID Instance ID Attribute ID Description Service data length (number of bytes) Service data field Get 14 48 1 11 1 Y Y: 1 self test 2 idle 3 self test exception 4 executing 5 abort This command returns the device status. Get 14 100 1 103 1 This command returns the device status. 1 = synchronization, 2 = POSITION CONTROL, 3 = CLOSED 4 = OPEN, 5 = PRESSURE CONTROL, 6 = HOLD, 7 = LEARN 12 = power failure, 13 = safety mode 14 = fatal error (read EXCEPTION DETAIL ALARM for details) Get 14 48 1 12 1 This command returns the exception status. Bit Explanation: (LSB) 0 0 (reserved) 1 0 (reserved) 2 This bit is set to 1 in case of a manufacturer specific alarm. 3 0 (reserved) 4 0 (reserved) 5 0 (reserved) 6 This bit is set to 1 in case of a manufacturer specific warning. (MSB) 7 1 The exception status byte only indicates that alarms or warnings are present. In order to find out which alarm or warning is present, you must read EXCEPTION DETAIL ALARM resp. EXCEPTION DETAIL WARNING. Get 14 48 1 With Attribute ID = 13 EXCEPTION DETAIL ALARM bytes will be returned. With Attribute ID = 14 EXCEPTION DETAIL WARNING bytes will be returned. For meaning see table on next page. 13 14 15 Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 48/94 Edition 2013-02-21 600773EA

INSTALLATION Command (DeviceNet term if deviant) EXCEPTION DETAIL ALARM EXCEPTION DETAIL WARNING Service Code Class ID Instance ID Attribute ID Description Service data length (number of bytes) Table with EXCEPTION DETAIL ALARM resp. EXCEPTION DETAIL WARNING bits. 0 OK 1 Exception / Failure / Error (except for detail size bytes) Data Component PCV Common Exception Detail Size PCV Common Exception Detail Byte #0 PCV Common Exception Detail Byte #1 PCV Device Exception Detail Size PCV Device Exception Detail Byte #0 PCV Device Exception Detail Byte #1 PCV Device Exception Detail Byte #2 PCV Device Exception Detail Byte #3 Manufacturer Exception Detail Size Manufacturer Exception Detail Byte #1 Manufacturer Exception Detail Byte #2 Manufacturer Exception Detail Byte #3 Manufacturer Exception Detail Byte #4 Manufacturer Exception Detail Byte #5 Manufacturer Exception Detail Byte #6 Service data field Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 Reserved Reserved Isolation valve position failure Sensor ratio exceeded PFO not ready Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Wrong Device Status 2 Wrong Access Mode Compressed air failure ADC not responding ZERO disabled Learn data set invalid Reserved Optional hardware missing Reserved Reserved Reserved Reserved Reserved Reserved PFO off Reserved Reserved Reserved Reserved Reserved Reserved Reserved 1) Refer to «Trouble shooting» for details on these fatal errors. Valve power OFF or internal com. error E40 1) Setpoint invalid (safe state) E22 1) IO data missing (safe state) E21 1) Setpoint type invalid (safe state) Service request Reserved No sensor Simulation active E20 1) Control mode invalid (safe state) Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 600773EA Edition 2013-02-21 49/94

INSTALLATION Command (DeviceNet term if deviant) THROTTLE CYCLE COUNTER ISOLATION CYCLE COUNTER Service Code Class ID Instance ID Attribute ID Description Service data length (number of bytes) Get 14 100 1 101 4 Service data field This command returns the number of throttle cycles. Data type is unsigned long integer. A movement from max. throttle position to open back to max. throttle position counts as one cycle. Partial movements will be added up until equivalent movement is achieved. Get 14 100 1 106 4 This command returns the number of isolation cycles. Data type is unsigned long integer. Each closing of the sealing ring counts as one cycle. Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 50/94 Edition 2013-02-21 600773EA

INSTALLATION 4.6.5 Explicit messaging setup commands Command (DeviceNet term if deviant) DATA TYPE GAIN PRESSURE GAIN POSITION POLL OUTPUT Service Code Class ID Instance ID Attribute ID Description Service data length (number of bytes) Service data field Set 16 49 1 3 1 X Get 14 49 1 3 1 X: 195 signed integer 202 floating point This command defines the data type for PRESSURE, SENSOR READING, OFFSET and POSITION. Set 16 49 1 14 4 X Get 14 49 1 14 4 X: gain, max. value is 3.2767, data type is floating point This command selects the gain for PRESSURE and allows for scaling. Default value is 1 (3Fh 80h 00h 00h). e.g.: Gain = 0.1 pressure value range results in 0-1 000 Gain = 1 pressure value range results in 0-10 000 Gain = 3.2767 pressure value range results in 0-32 767 Set 16 49 3 14 4 X Get 14 49 3 14 4 X: gain, max. value is 3.2767, data type is floating point This command selects the gain for POSITION and allows for scaling. Default value is 1 (3Fh 80h 00h 00h, high byte first notation). e.g.: Gain = 0.1 position value range results in 0-1 000 (3Dh CCh CCh CCh) Gain = 1 position value range results in 0-10 000 (3Fh 80h 00h 00h) Gain = 3.2767 position value range results in 0-32 767 (40h 51h B5h 73h) Set 16 5 2 100 1 X Get 14 5 2 100 1 X: output assembly object number (7, 8, 102) This command configures resp. reads the output assembly for poll connection. POLL INPUT BIT STROBE INPUT Set 16 5 2 101 1 X Get 14 5 2 101 1 X: input assembly object number (3, 4, 5, 13, 14, 100, 101) This command configures resp. reads the input assembly for polling. Not implemented Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 600773EA Edition 2013-02-21 51/94

INSTALLATION Command (DeviceNet term if deviant) CHANGE OF STATE / CYCLING INPUT ACCESS MODE POWER UP CONFIGURATION POWER FAIL CONFIGURATION Service Code Class ID Instance ID Attribute ID Service data length (number of bytes) Service data field Set 16 5 4 101 1 X Get 14 5 4 101 1 X: input assembly object number (3, 4, 5, 13, 14, 100, 101) This command configures resp. reads the input assembly for change of state / cycling. Set 16 100 1 107 1 X Get 14 100 1 107 1 X: 0 Local (operation via service port) 1 Remote (operation via DeviceNet ) 2 Locked (in remote mode) This command controls / returns the access mode of the valve. Set 16 100 1 112 1 X Get 14 100 1 112 1 X: 0 closed 1 open This command controls / returns the valve position after power up. Set 16 100 1 113 1 X Get 14 100 1 113 1 X: 0 closed 1 open This command controls / returns the target valve position in case of a power failure. Only for versions that have Power Fail Option equipped [650.. -.. C. -.... or 650.. -.. H. -.... or 650.. -.. U. -.... or 650.. -.. W. -....]. Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 52/94 Edition 2013-02-21 600773EA

INSTALLATION Command (DeviceNet term if deviant) SENSOR MODE SENSOR RATIO ZERO CONTROL ZERO Service Code Class ID Instance ID Attribute ID Service data length (number of bytes) Service data field Set 16 49 1 101 1 X Get 14 49 1 101 1 X: 0 no sensor 1 1 sensor operation (sensor 1 input) 2 2 sensor operation with automatic changeover (low range = sensor 2 input, high range = sensor 1 input) 3 1 sensor operation (sensor 2 input) 4 2 sensor operation with automatic changeover (low range = sensor 1 input, high range = sensor 2 input) This command controls / returns the sensor mode for pressure control. Sensor modes 2, 3 and 4 are possible with 2 sensor hardware [650.. -... Q -.... ] only. For applications where the high range sensor is used for for monitoring purpose only, select sensor operation modes 1 or 3 for pressure control with low range sensor and read high range sensor from SENSOR 1 READING resp. SENSOR 2 READING. Set 16 49 1 103 2 or 4 X Get 14 49 1 103 2 or 4 X: sensor ratio according to selected DATA TYPE, range is 100 10 000 This command defines the sensor ratio for 2 sensor operation. Sensor ratio = high range sensor full scale / low range sensor full scale * 100. Set 16 49 1 102 1 X Get 14 49 1 102 1 X: 0 Disable 1 Enable This command enables resp. disables the ZERO command. In case it is disabled ZERO does not work. 75 49 1 This command initiates ZERO. Refer to «ZERO (setup step 4)» for correct zero procedure. Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 600773EA Edition 2013-02-21 53/94

INSTALLATION Command (DeviceNet term if deviant) LEARN PRESSURE LIMIT (calibration scale) LEARN (calibration service) DOWNLOAD LEARN DATA UPLOAD LEARN DATA Service Code Class ID Instance ID Attribute ID Service data length (number of bytes) Service data field Set 16 51 1 100 2 or 4 Y Get 14 51 1 100 Y: learn pressure limit according to selected DATA TYPE, nominal pressure range is 0 10 000 (sensor full scale) but it may be scaled, refer also to command GAIN for details. This command transfers/reads the pressure limit for LEARN. Refer to «LEARN (setup step 5)» for correct learn pressure limit setting. 100 51 1 0 This command starts LEARN. With MODE commands open valve or close valve the routine may be interrupted. Without LEARN the PID controller is not able to perform pressure control. Refer to «LEARN (setup step 5)» for correct learn gas flow and procedure. 51 48 1 11 XY X: index (000.. 103, whereas these indices must be ASCII coded, e.g. 000 = 30h 30h 30h, 001 = 30h 30h 31h, etc.) Y 8 data bytes ASCII coded (e.g. 30h 32h 33h 33h 33h 30h 33h 36h) Example of XY: 30h 30h 30h 30h 32h 33h 33h 33h 30h 33h 36h (11 bytes in total) This command loads the learn data sets from the host down to the valve. There are a total number of 104 data sets. Each data set needs to be downloaded separately. 50 48 1 3 X X: index (000.. 103, whereas these indices must be ASCII coded, e.g. 000 = 30h 30h 30h, 001 = 30h 30h 31h, etc.) This command loads the learn data sets from the valve up to the host. There are a total number of 104 data sets which need to be uploaded separately. Each answer consists of 11 bytes. Whereas the leading 3 bytes are the data set index followed by 8 data bytes. Data are ASCII coded. Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 54/94 Edition 2013-02-21 600773EA

INSTALLATION Command (DeviceNet term if deviant) PID CONTROLLER GAIN FACTOR PID CONTROLLER SENSOR DELAY PID CONTROLLER SETPOINT RAMP VALVE SPEED Service Code Class ID Instance ID Attribute ID Service data length (number of bytes) Service data field Set 16 51 1 105 1 X Get 14 51 1 105 1 X: 0 = 0.10, 1 = 0.13, 2 = 0.18, 3 = 0.23, 4 = 0.32, 5 = 0.42, 6 = 0.56 7 = 0.75, 8 = 1.00, 9 = 1.33, 10 = 1.78, 11 = 2.37, 12 = 3.16, 13 = 4.22 14 = 5.62, 15 = 7.50, 16 = 0.0001, 17 = 0.0003, 18 = 0.001, 19 = 0.003, 20 = 0.01, 21 = 0.02, 22 = 0.05 This command selects/returns the gain factor for the PID controller. Refer to «Gain factor adjustment» for details. Set 16 51 1 107 1 X Get 14 51 1 107 1 X: 0 = 0, 1 = 0.02, 2 = 0.04, 3 = 0.06, 4 = 0.08, 5 = 0.10, 6 = 0.15 7 = 0.20, 8 = 0.25, 9 = 0.30, 10 = 0.35, 11 = 0.4, 12 = 0.5, 13 = 0.6 14 = 0.8, 15 = 1.0 This command selects/returns the sensor delay for the PID controller. Refer to «Sensor delay adjustment» for details. Set 16 51 1 108 1 X Get 14 51 1 108 1 X: 0 = 0, 1 = 0.5, 2 = 1.0, 3 = 1.5, 4 = 2.0, 5 = 2.5, 6 = 3.0 7 = 3.5, 8 = 4.0, 9 = 4.5, 10 = 5.0, 11 = 5.5, 12 = 6.0, 13 = 6.5 14 = 7.0, 15 = 7.5, 16 = 8.0, 17 = 8.5, 18 = 9.0, 19 = 9.5, 20 = 10.0 This command selects/returns the setpoint ramp for the PID controller. Refer to «Setpoint ramp adjustment» for details. Set 16 51 2 101 2 X Get 14 51 2 101 2 X: valve speed, 1 1000 (1 = min. speed, 1000 = max. speed), This command selects/returns the actuating speed for the valve plate. Data type is unsigned integer. Speed selection is effective for pressure control and position control. Open valve and close valve are always done with max. speed. Refer to «Valve speed adjustment» for details. Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter h (e.g. 31h) 600773EA Edition 2013-02-21 55/94

OPERATION 5 Operation Unqualified personnel WARNING Inappropriate handling may cause serious injury or property damage. Only qualified personnel are allowed to carry out the described work. Valve opening Risk of serious injury. WARNING Human body parts must be kept out of the valve opening and away from moving parts. Do not connect the controller to power before the valve is installed complete into the system. 5.1 Normal operation This valve is designed for downstream pressure control in vacuum chambers. It can be employed in a pressure control mode or a position control mode. In both cases local or remote operation is possible. 56/94 Edition 2013-02-21 600773EA

OPERATION 5.1.1 Local operation Local operation means that the valve is operated via the service port using a computer or the Service Box 2. When using a computer, a service cable and a software from VAT is required. You can use our Software (freeware) 'Control Performance Analyzer' which can be downloaded from: http://www.vatvalve.com/customer-service/informations-and-downloads/control-performance-analyzer. These softwares are beneficial especially for setup, testing and maintenance. How to start: Connect service cable between PC and valve controller, start software and push button LOCAL to enable for operation. Then enter menu Sensor / Setup and do sensor configuration according to your application to make sure that you get the correct pressure displayed. 'Control Performance Analyzer' supports: - Valve setup - Sensor setup - Pressure control - Interface setup - Manual control - Sequence ontrol - Numeric and graphical monitoring - Data recording - Data analysis - Advanced diagnostic When communication to service port is interrupted the valve will change to remote operation. So when service cable will be disconnected or software will be shut down, the valve returns automatically to remote operation. This may result in an immediate movement of the valve depending on remote control. Refer to «Accessories» for ordering numbers of service cable and Service Box 2. 600773EA Edition 2013-02-21 57/94

OPERATION 5.1.2 Remote operation This product is equipped with a DeviceNet interface to allow for remote operation. See section «DeviceNet interface» for details. 'Control Performance Analyzer' software or 'Service Box 2' may be used for monitoring during remote control. 'Control Performance Analyzer' software 'Service Box 2' In case Control Performance Analyzer software is connected to valve make sure REMOTE button is pushed to enable for remote operation. In case Service Box 2 is connected to valve make sure the LED on button LOCAL is OFF for remote operation. 58/94 Edition 2013-02-21 600773EA

OPERATION 5.2 Close valve Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Push CLOSE button Remote operation: (Refer to chapter «Explicit messaging control commands» for details) 1. Send EXECUTING (if not yet selected) 2. Send SETPOINT TYPE = position control 3. Send CONTROL MODE for position = close valve 5.3 Open valve Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Push OPEN button Remote operation: (Refer to chapter «Explicit messaging control commands» for details) 1. Send EXECUTING (if not yet selected) 2. Send SETPOINT TYPE = position control 3. Send CONTROL MODE for position = open valve 5.4 Position control The valve position is directly controlled according to the position setpoint. Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Select or enter position setpoint Remote operation: (Refer to chapter «Explicit messaging control commands» for details) 1. Send EXECUTING (if not yet selected) 2. Send SETPOINT TYPE = position control 3. Send CONTROL MODE for position = control mode 4. Send CONTROL SETPOINT = position 600773EA Edition 2013-02-21 59/94

OPERATION 5.5 Pressure control To prepare valve for PRESSURE CONTROL perform complete «Setup procedure». The valve has parameters that may be modified to tune pressure control performance. Refer to «Tuning of control performance». The included PID controller controls the chamber pressure according to the pressure setpoint by means of the valve position. The PID controller works with an adaptive algorithm to achieve best results under altering conditions (gasflow, gas type). Local operation: ( Control View, Control Performance Analyzer or Service Box 2 ) Select or enter pressure setpoint Remote operation: (Refer to chapter «Explicit messaging control commands» for details) 1. Send EXECUTING (if not yet selected) 2. Send SETPOINT TYPE = pressure control 3. Send MODE for pressure = control mode 4. Send CONTROL SETPOINT = pressure 5.5.1 Pressure control operation with 2 sensors [applicable with 650.. -... Q -.... version only] If 2 sensor operation is enabled, changeover between the sensors is done automatically during pressure control. For configuration refer to chapter «Setup procedure». We recommend a ratio of 10:1 between the pressure gauges. Max. ratio is 100:1. High range respectively low range pressure gauge may be either connected to sensor 1 or sensor 2 input. It s required to do correct sensor configuration. Between 90 and 100% of the low range sensor full scale, the low range sensor is phased out while high range sensor is phased in during pressure rise. During pressure decrease the high range sensor is phased out while low range sensor is phased in. This maintains a functional response behavior in case of small calibration errors between the two sensors. The PRESSURE output in this range is a blend between both sensors. For monitoring purpose each sensor signal may be read out individually. Refer to «Explicit messaging inquiry commands SENSOR 1 READING and SENSOR 2 READING». Make sure that both sensors are calibrated. Do not close optional gauge isolation valves during the transition phase between the sensors. 60/94 Edition 2013-02-21 600773EA

OPERATION 5.6 Display information There is a 4 digit display located on the panel. It displays configuration, status and position information. For details see following tables. 1 2 3 4 Display 5.6.1 Power up Description Digit 1 Digit 2 Digit 3 Digit 4 At first all dots are illuminated then configuration is displayed: 1 E 0 0 Firmware version [e.g. 1E00] (1st information for about 2s) 0 = basic Controller configuration (2nd information for about 2s) SYNC indicates that power up synchronization is running. In case D C or D999 is displayed, motor interlock is active. Refer to «Safety mode» for details. If valve is closed (isolated) display shows alternately C C and INIT. Syncronization will be done when first movement command is received. 4 = DeviceNet Interface 1 = with SPS 1) 2 = with PFO 2) 3 = with SPS 1) and PFO 2) 1 = 1 sensor version 2 = 2 sensor version S Y N C 1) SPS = optional ±15 VDC Sensor Power Supply module 2) PFO = Power Failure Option 600773EA Edition 2013-02-21 61/94

OPERATION 5.6.2 Operation Description / Mode Digit 1 Digit 2 Digit 3 Digit 4 PRESSURE CONTROL mode POSITION CONTROL mode Valve closed Valve open HOLD (position frozen) activated ZERO running LEARN running Safety mode established. Refer to «Safety mode» for details. P V C O H Z L D 0... 100 = valve position (%, 0 = closed / 100 = open) Service request 1) S R Power failure 1) SR is blinking alternatively with the actual mode display (e.g. C SR) F 5.6.3 Errors Description Digit 1 Digit 2 Digit 3 Digit 4 Compressed air failure (< 4 bar / 55 psi) A I R f Compressed air on exhaust A I R x Fatal error occurred E Error code. Refer to «Trouble shooting» for details 5.6.4 Safety mode By means of an external switch (see connection diagrams «Electrical connection») the motor power supply can be interrupted. In this case the valve enters the safety mode. This motor interlock prevents the valve from moving (e.g. maintenance work). Data reading from the control unit remains possible. When motor interlock is active during power up the valve directly enters the safety mode and is not able to synchronize. Display shows D C or D999. In this case synchronization cycle will be done when motor interlock is deactivated. Then Display shows INIT for a moment followed by SYNC. When safety mode is entered from operation (i.e. pressure control mode), the unit will automatically switch to position control mode and remain at current position. Once motor interlock is deactivated the unit remains in position control mode. 62/94 Edition 2013-02-21 600773EA

OPERATION 5.7 Operation during power up Valve position before power up: Closed (isolated) All other than closed (not isolated) Reaction of valve: Valve power up configuration = closed Valve power up configuration = open (default) Valve remains closed. Valve runs to max. throttle position to Display shows alternately C C and detect the limit stops to synchronize. INIT. Display shows configuration of Synchronization will be done when product resp. SYNC until first movement command is received. synchronization is done. Valve position after power up is open. Valve runs to max. throttle position to detect limit stop for synchronization. Display shows configuration of product resp. SYNC until synchronization is done. Valve position after power up is Valve position after power up is open closed Refer also to chapter: «Display information». 5.8 Behavior in case of power failure Valve position before power failure: Any Reaction of valve: With Power Failure Option (PFO) 650.. -..H. -.... / 650.. -..C. -.... 650.. -..U. -.... / 650.. -..W. -.... Valve will close or open depending on valve configuration. Default is close. Provide that battery pack of the VAT controller is charged. Display indicates F. All parameters are stored in a power fail save memory. Technical data of Power Failure Option (PFO): Charging time Durability 2 minutes max. up to 10 years @ 25 C ambient Refer to chapter: «Option board» for more details 600773EA Edition 2013-02-21 63/94

OPERATION 5.9 Operation under increased temperature Hot valve CAUTION Heated valve may result in minor or moderate injury. Do not touch valve and heating device during operation. Once heating is switched off (valve and system) await until the valve is cooled down complete before doing any work. This valve may be operated in the temperature range mentioned in chapter «Technical data». 5.10 Behavior In case of compressed air pressure drop Valve position before pressure drop: Valve closed Valve open or in any intermediate position Reaction of valve: Valve remains closed. Sealing ring moves down and blocks the pendulum plate at the current position. Refer to chapter: «Troubleshooting» for details. 64/94 Edition 2013-02-21 600773EA

TROUBLE SHOOTING 6 Trouble shooting Failure Check Action No dots lighted on display - 24 V power supply ok? - Connect valve to power supply according to «Electrical connection» and make sure that power supply is working. Module Status LED is off Module Status LED is flashing green Module Status LED is flashing red (recoverable fault) Module Status LED is red (unrecoverable fault) Network Status LED is off (Device is not on line) Network Status LED is flashing green (on line but no connections in the established state) Network Status LED is flashing red (time out) - DeviceNet power supply ok? - Connect valve to DeviceNet according to «DeviceNet connection» and make sure that power is provided. - Refer to ODVA specification volume II, release 2.0 (incl. errata 1) «IDENTITY OBJECT, figure 6.2, state event matrix for identity object» - Refer to ODVA specification volume II, release 2.0 (incl. errata 1) «IDENTITY OBJECT, figure 6.2, state event matrix for identity object» - The controller needs commissioning due to missing, incomplete or incorrect configuration. - Refer to ODVA specification volume II, release 2.0 (incl. errata 1) «IDENTITY OBJECT, figure 6.2, state event matrix for identity object» - Refer to ODVA specification volume II, release 2.0 (incl. errata 1) «IDENTITY OBJECT, figure 6.2, state event matrix for identity object» - DeviceNet power supply ok? - Connect valve to DeviceNet according to «DeviceNet connection» and make sure that power is provided. - Are I/O connections in the time out state? - Allocate device to master - Reestablish I/O connections. Network Status LED is red Controller does not respond to DeviceNet commands Controller does either not respond or respond in an unexpected way to DeviceNet commands Read back from controller is wrong during polling - Node number and baudrate correct? - Failed communication device. The device has detected an error that has rendered it incapable of communicating on the network. - Proceed according to «Setup procedure, DeviceNet configuration». - Configuration correct? - Send FACTORY RESET and redo complete configuration. Refer to «Explicit messaging control commands, FACTORY RESET» and «Setup procedure, DeviceNet configuration» for details. - Check poll rate - Refer to «Setup procedure, DeviceNet configuration» for details. 600773EA Edition 2013-02-21 65/94

TROUBLE SHOOTING Failure Check Action Remote operation does not work - Local operation via service - Switch to remote operation. port active Display shows «E 20» (fatal error - limit stop of valve unit not detected) Display shows «E 21» (fatal error - rotation angle of valve plate limited during power up) Display shows «E 22» (fatal error - rotation angle of valve plate limited during operation) Display shows «E 40» (fatal error - motor driver failure detected) Display shows «D C» or «D999» Motor Interlock is open Display shows «SR» (Service Request) CLOSE VALVE does not work OPEN VALVE does not work Display shows «M C Maintenance mode active Display shows «M100» Maintenance mode active POSITION CONTROL does not work COMPRESSED AIR FAILURE «AIRf» COMPRESSED AIR FAILURE at Exhaust «AIRx» - Safety mode active, check for D on display? - Valve plate mechanically obstructed? - Valve plate mechanically obstructed? - Provide power to motor to allow for operation. - Refer to «Electrical connection» for details. - Replace actuator according to «Maintenance procedures». - Resolve obstruction. - Resolve obstruction. - Replace control unit according to «Maintenance procedures». - Motor power supplied? - Provide power to motor to allow for operation. - Refer to «Electrical connection» for details. - Valve unit heavy contaminated or gate seal heavily sticking? - Safety mode active, check for D on display? - Maintenance mode active - Safety mode active, check for D on display? - Maintenance mode active - Safety mode active, check for D on display? - POSITION CONTROL selected, check for V on display? - No or too less air pressure on air input of valve - Wrong connection of compressed air input and output - No compressed air at output exhaust - Clean valve and/or replace gate seal according to «Maintenance procedures». - Provide power to motor to allow for operation. - Refer to «Electrical connection» for details. - Refer to Display shows «M C» in this table - Provide power to motor to allow for operation. - Refer to «Electrical connection» for details. - Refer to Display shows «M100» in this table - Pin 14 of service connector is connected to ground. Plate will close. Further movement of plate is blocked. 1) - Pin 13 of service connector is connected to ground. Plate will open. Further movement of plate is blocked. 1) - Provide power to motor to allow for operation. - Refer to «Electrical connection» for details. - Select POSITION CONTROL mode. Refer to «Position control» for details. - Connect air or increase air pressure. Make sure that the air pressure is more than 4 bar (55 psi). - Connect compressed air in accordance chapter installation. - Contact your local VAT service centre for support. 1)Priority of pin 14 is higher than pin 13. If pin 14 is connected to ground after pin 13 the valve will close. Ground of service connector is at pin 4 and 8. 66/94 Edition 2013-02-21 600773EA

TROUBLE SHOOTING Failure Check Action Pressure reading is wrong - Sensor(s) connected? - Refer to «Electrical connection». or - 2 sensor version present at - Check valve version on page 1. Verify configuration. pressure reading is negative valve controller? Refer to «Setup procedure». - Refer to «Pressure control operation with 2 sensors». ZERO does not work - ZERO done? - Perform ZERO when base pressure is reached. Refer to «ZERO» for details. - Does sensor power supply provide enough power for sensor(s)? - Valve in open position, check for O on display? - Verify sensor supply voltage. - OPEN VALVE and bring chamber to base pressure before performing ZERO. - ZERO disabled? - Enable ZERO. Refer to «Valve and sensor configuration» for details. Pressure is not 0 after ZERO - Sensor voltage shifting? - Wait until sensor does not shift any more before performing ZERO. PRESSURE CONTROL does not work - System pumped to base pressure? - Sensor offset voltage exceeds ±1.4V - Safety mode active, check for D on display? - PRESSURE CONTROL selected, check for P on display? - OPEN VALVE and bring chamber to base pressure before performing ZERO. - Replace pressure gauge. - Provide power to motor to allow for operation. - Refer to «Electrical connection» for details. - Select PRESSURE CONTROL mode. Refer to «Pressure control» for details. - LEARN done? - Perform LEARN. Refer to «Setup procedure» for details. PRESSURE CONTROL not optimal - Setup done completely? - Perform «Setup procedure» completely. - LEARN done? - Perform LEARN. Refer to «LEARN» for details. - ZERO performed before LEARN? - Perform ZERO then repeat LEARN. Refer to «Setup procedure» for details. - LEARN interrupted? - Repeat LEARN. Refer to «LEARN» for details. - Was gas flow stable during LEARN? - Repeat LEARN with stable gas flow. Refer to «LEARN» for details. - Tuning done? - Tune valve for application. - Refer to «Tuning of control performance» for details. - Is sensor range suited for application? - Use a sensor with suitable range (controlled pressure should be >3% and < 98% of sensor full scale). - Noise on sensor signal? - Make sure a shielded sensor cable is used. If you need any further information, please contact one of our service centers. You will find the addresses on our website: www.vatvalve.com. 600773EA Edition 2013-02-21 67/94

MAINTENANCE 7 Maintenance Unqualified personnel WARNING Inappropriate handling may cause serious injury or property damage. Only qualified personnel are allowed to carry out the described work. Valve opening Risk of serious injury. WARNING Human body parts must be kept out of the valve opening and away from moving parts. Disconnect power on controller before doing any work. Hot valve CAUTION Heated valve may result in minor or moderate injury. Do not touch valve and heating device during operation. Once heating is switched off (valve and system) await until the valve is cooled down complete before doing any work. Contamination NOTICE Gate and other parts of the valve must be protected from contamination. Always wear clean room gloves when handling the valve. 7.1 Maintenance intervals Under clean operating conditions, the valve does not require any maintenance during the specified cycle life. Contamination from the process may influence the function and requires more frequent maintenance. Before carrying out any maintenance, please contact VAT. It has to be individually decided whether the maintenance can be performed by the customer or has to be carried out by VAT. Please write down the fabrication number of the valve before contact VAT. Refer to chapter «Identification of product» for fabrication number. 68/94 Edition 2013-02-21 600773EA

MAINTENANCE 7.2 Maintenance procedures Two preventive maintenance procedures are defined for this valve. These are: Replacement of isolation seals (gate and body seal of sealing ring) and valve cleaning. Refer to chapter: «Replacement of isolation seals and cleaning». Replacement of actuator and actuator shaft seals. Refer to chapter: «Replacement of actuator and actuator shaft seals». Required frequency of cleaning and replacement of seals is depending on process conditions. A critical factor influencing the maintenance period is the lifetime of the vacuum grease, being limited under increased temperature. In this case grease will separate to PTFE and oil. The oil may flow and contaminate the valve parts. VAT can give the following recommendations for preventive maintenance: Replacement of unheated 1) heated 80 C 1) heated > 80 C 1) isolation seals (gate and 200 000 cycles 6 months but 3 months but body seal of sealing ring) max. 200 000 cycles max. 200 000 cycles actuator shaft seals 1 000 000 cycles 6 months 3 months See figure below: Vacuum grease NOTICE Vacuum grease may be distributed and contaminate the valve. Prevent gap between body and sealing ring from air gun cleaning. Do not clean the gap between body and sealing ring with compressed air. Body Gap Sealing ring Plate 600773EA Edition 2013-02-21 69/94

MAINTENANCE 7.2.1 Replacement of isolation seals and cleaning 7.2.1.1 Required tools Allen Wrench 5 mm Open end wrench 13 mm O-ring removal tool (see chapter: Accessories) Vacuum grease (see chapter: Spare parts) Clean room wiper Isopropyl alcohol VAT cleaning tool (see chapter: Accessories) Electrical power and compressed air is required to perform steps 2 to 9 during disassembly respectively 9 to 2 during assembly. Description Required tool 1. Vent both valve chambers. 2. Open the 4 bonnet screws and remove valve bonnet. Allen wrench 5 mm 3. Open the valve Caution: Pay attention plate moves out! 4. Unfasten mounting screw for pendulum plate. (For reinstall the pendulum plate, tighten the mounting screw to block.) 5. Remove pendulum plate. mounting screw for pendulum plate Open end wrench 13 mm 70/94 Edition 2013-02-21 600773EA

MAINTENANCE Description Required tool 6. With one hand press the [Maintenance button] to lower the sealing ring, with your second hand unlock the sealing ring by pressing the handle. 7. Release [Maintenance button]. 8. Remove sealing ring. 9. To prevent the shaft and retaining pins from moving during work, switch the valve to safety mode. Refer to «Safety mode» for details. Retaining pins will move up. unlock lock Maintenance button 10. Remove gate and body seal from sealing ring carefully with a soft tool. 11. Remove grease residues at sealing ring with lint-and dust-free towel a little soaked with isopropyl alcohol. Clean sealing ring and pendulum plate with lint-and dust-free cloth little soaked with isopropyl alcohol or in an ultrasonic bath. 12. Clean out valve body with alcohol. Use VAT cleaning tool or an appropriate non metal tool with a cloth to enter valve body. Do not enter valve body with hands! 13. Clean or replace gate seal if necessary. Install gate seal to sealing ring without grease. 14. Clean or replace body seal if necessary. Lubricate body seal with the quantity of vacuum grease listed in the table to the right. gate seal body seal Valve size Quantity of grease [ml] 160 0.15 O-ring removal tool VAT cleaning tool Isopropyl alcohol Clean room wiper O-ring removal tool Vacuum grease 15. Install body seal into sealing ring. 16. Deposit vacuum grease on the bottom side of the body seal according to drawing below. Pay attention that the quantity of vacuum grease listed in the table to the right is distributed constantly over the whole circumference. Valve size Quantity of grease [ml] 160 0.25 Vacuum grease 600773EA Edition 2013-02-21 71/94

MAINTENANCE Description Required tool Apply grease deposit on this side Vacuum grease 17. Clean the valve body. VAT cleaning tool Isopropyl alcohol 18. Reassembly the valve in reverse order, step 9 3. 19. Clean the valve sealing surface. Isopropyl alcohol Clean room wiper 20. Clean the bonnet. VAT cleaning tool Isopropyl alcohol 21. Clean the valve bonnet o-ring. If necessary, replace the bonnet o-ring. Clean room wiper 22. Close the valve bonnet. Tightening the bonnet screws with 6Nm. Allen wrench 5mm 72/94 Edition 2013-02-21 600773EA

MAINTENANCE 7.2.2 Replacement of actuator shaft seals 7.2.2.1 Required tools Allen Wrench 2 mm Allen Wrench 4 mm Allen Wrench 5 mm Open end wrench 13 mm VAT cleaning tool (see chapter: Accessories) Vacuum grease (see chapter: Spare parts) Clean room wiper Isopropyl alcohol O-ring removal tool (see chapter: Accessories) Electrical power and compressed air is required to perform steps 2 to 9 during disassembly respectively 9 to 2 during assembly. Description Required tool 1. Vent both valve chambers. 2. Open the 4 bonnet screws and remove valve bonnet. Allen wrench 5 mm 3. Open the valve Caution: Pay attention plate moves out! 4. Unfasten mounting screw for pendulum plate. (For reinstall the pendulum plate, tighten the mounting screw to block.) 5. Remove pendulum plate. mounting screw for pendulum plate Open end wrench 13 mm 600773EA Edition 2013-02-21 73/94

MAINTENANCE Description Required tool 6. With one hand press the [Maintenance button] to lower the sealing ring, with your second hand unlock the sealing ring by pressing the handle. 7. Release [Maintenance button]. 8. Remove sealing ring. 9. To prevent the shaft and retaining pins from moving during work, switch the valve to safety mode. Refer to «Safety mode» for details. Retaining pins will move up. unlock lock Maintenance button CV software 10. Release the valve from safety mode. Refer to «Safety mode» for details 11. Move the valve to position 50% (half opened) This is necessary, in order to dismount the actuator. See steps 19 to 21. 12. Disable PFO option feature via 'Power Fail Status' in menu 'System' of CV or CPA software, and turn off the power or CPA software Service box 2 13. Disconnect 24VDC power. Wait for 60s, then disconnect cables and compressed air from valve actuator. 14. Unfasten all 4 controller screws and lift the controller carefully from actuator. Allen wrench 4 mm 74/94 Edition 2013-02-21 600773EA

MAINTENANCE Description Required tool 15. Unfasten all 3 actuator screws and remove actuator. Allen wrench 5 mm 16. Remove actuator shaft seals carefully with soft tool. O-ring removal tool 17. Clean the actuator feed through and grooves. Clean room wiper Isopropyl alcohol 18. Lubricate each o-ring groove with 0.1 ml vacuum grease. Pay attention that grease is distributed constantly over the whole circumference. Vacuum grease 19. Clean or replace seals if necessary. 20. Lubricate each o-ring with 0.05 ml vacuum grease. 21. Install o-rings. 22. Deposit 0.1 ml vacuum grease on each o-ring. Pay attention that grease is distributed constantly over the whole circumference. Vacuum grease 600773EA Edition 2013-02-21 75/94

MAINTENANCE Description Required tool 23. Remove fixation kit and mounting screw for pendulum plate. 24. Clean screw and slightly lubricate thread. Then reinstall fixation kit. 25. Clean actuator shaft and lubricate it with 0.1 ml vacuum grease. Vacuum grease 26. Install actuator Tighten actuator screws with 6 Nm. Remove vacuum grease from actuator shaft face after installation. Allen wrench 5 mm 27. Install controller Tighten the controller screws with 3 Nm. Connect cables at controller Connect compressed air at actuator Allen wrench 4 mm 28. Turn on power of controller. Caution: Valve moves to close position 29. Open valve and install sealing ring and pendulum plate in reverse order as they had been disassembled (steps 9 to 3). Open end wrench 13 mm 76/94 Edition 2013-02-21 600773EA

MAINTENANCE Description Required tool If actuator was replaced, proceed with step 30, otherwise go to step 34. DN Distance D[mm] between bonnet flange surface and pendulum plate. 30. Close valve and check if pendulum plate is in center of flange. Check can be done either visual or by measurement. When the valve is mounted to a tool, the bonnet has to be removed and the center position can be measured by a depth gauge (see picture). If the centering (or distance D) is not correct, proceed with step 31. 160 45.0 ±0.5 Adjusting screw mounted either in actuator position «B1 standard» or «B2 option» 31. If necessary adjust pendulum plate: a. Move pendulum plate a little towards open (e.g. position 1% of full stroke) b. Use adjustment screw at flange side of actuator (1 turn clockwise adjusts pendulum plate by about 3mm towards open). c. Restart valve in menu System/Recovery d. Check pendulum plate position according step 37 and redo adjustment procedure if necessary. Allen wrench 2 mm 32. Clean the valve sealing surface Clean room wiper Isopropyl alcohol 33. Clean the valve bonnet o-ring Clean room wiper 34. Mount valve bonnet. Tightening torques for bonnet screws, see in table to the right. Max. torque 6 Nm Allen wrench 5 mm 600773EA Edition 2013-02-21 77/94

MAINTENANCE 7.2.3 Replacement of Option board Electrostatic discharge Electronic components could be damage. NOTICE All work on the control and actuating unit has to be done under ESD protected environment to prevent electronic components from damage. Burned connector pins (spark) NOTICE Connector pins or electronic parts could damage, if plugged and unplugged under power. Do not plug or unplug connectors under power. The option board may or may not be equipped in your valve depending on the order. Refer to page 1 of this manual to check valve version. This board includes the optional modules for the valve which are: ±15 VDC sensor power supply (SPS) Power failure option (PFO) It is available in 3 versions. These are: SPS module only PFO module only SPS and PFO module The modules may be retrofitted or replaced easily. The battery lifetime of the PFO module depends on the ambient temperature (see below). To assure PFO function the option board must be replaced after battery life has expired. For ordering number of the modules refer to chapter «Spare parts». 78/94 Edition 2013-02-21 600773EA

Durability [months] MAINTENANCE 7.2.3.1 Durability of power fail battery The curves in the graph show the estimated life of Ultra Cap PFO in the worst condition (max. sensor load = 1 A, valve heating temperature = 150 C). If the SPS is not fully loaded (< 1 A) or heating temperature of valve body is lower than 150 C, the corresponding life time curve will be somewhere in between the upper and the lower curve. Therefore please determine the equivalent maintenance period for replacing the Ultra Cap battery (Option board). 120 100 80 60 40 w/o SPS module, valve unheated with SPS module, valve unheated w/o SPS module, valve heated with SPS module, valve heated 20 0 20 25 30 35 40 45 50 Ambient temperature [ C] This graph shows estimated life of Ultra Cap PFO for reference and not as guaranteed value. 600773EA Edition 2013-02-21 79/94

MAINTENANCE 7.2.3.2 Retrofit / replacement procedure Top view on control and actuating unit with panel removed: Master board Option board Interface board All boards have a fixed position into control and actuating unit. It is not possible to fit a board in other position as shown in picture above! Do not try out other positions, which maybe destroy the socket of boards! 80/94 Edition 2013-02-21 600773EA

MAINTENANCE 7.2.3.3 Needed tools Pozidriv screw driver size 1 Open end wrench 10 mm Open end wrench 4.5mm Description Required tool 1. Write down the «NODE ADDRESS» and «DATA RATE» in case of Interface board replacement. Ballpoint 2. Remove female screw locks from POWER and SENSOR connectors. Open end wrench 4.5 mm 3. Remove the panel screws. Pozidriv screw driver size 1 4. Loosen and remove the LOCIC connector screw Open end wrench 10mm 600773EA Edition 2013-02-21 81/94

MAINTENANCE Description Required tool 5. Lift the panel carefully. 6. Pull out the option board a little. 7. Push the connector release (1) a little down and disconnect fan cable (2) from option board. 2 1 8. Push the connector release (1) a little down and disconnect DeviceNet cable (2) from interface board. 1 2 9. Remove or replace interface board. 82/94 Edition 2013-02-21 600773EA

MAINTENANCE Description Required tool 10. Remove or replace master board. 11. Remove or replace option board. 12. Insert master board and interface board in reverse order as disassembled at correct positions (see steps 9 to 8). 13. Reconnect DeviceNet cable to interface board (see step 7). 14. Reconnect fan cable to option board (see steps 6 to 5). 15. Place the panel and tighten panel screws with 1.1 Nm (see steps 4 to 3). 16. Tighten female screw locks from POWER and SENSOR connectors with 1.1 Nm (see step 2). Pozidriv screw driver size 1 Open end wrench 4.5 mm 17. In case of replacement Interface board, adjust the «NODE ADDRESS» and «DATA RATE» on new Interface board that you wrote down on step 1. If you need any further information, please contact one of our service centers. You can find the addresses on our website: www.vatvalve.com. 600773EA Edition 2013-02-21 83/94