ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

Similar documents
Low voltage. Acti 9. the efficiency you deserve. Multi 9 > Acti 9 Cross-reference guide

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

Domae. The right solution for distribution boards

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

and other modular devices for low voltage installation

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Residual Current Circuit-breaker (RCCB) FH 200 Series

max pole for t=15 ms

DSE201 Compact design with enhanced protection

COMPLETE SOLUTIONS FOR POWER PROTECTION

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

DX³ 4-pole RCBO 6000 A/10 ka

cor Long Run Experience

Wall mounted switchgear

Technical Journal September 2012

MS25, MST25, MS20, MST20

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

MINIATURE CIRCUIT BREAKER

Btdin RCBO 6000A up to 63A (2P)

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

DPX moulded case circuit breakers

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants

R.C.B.O. SP / 1 module

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Ready to install Distribution boards, DIN rail mounted equipment, enclosures and connection systems

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

DPX 1600 Electronic release

QUALITY ASSURANCE & DOCUMENTATION

DX³ RCCBs - ID 4P up to 100 A

MS25, MST25, MS20, MST20

The effective choice The benefits of a product with the highest quality standards

New DX 3 High rating & breaking capacity

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

Low Voltage A GE Power Controls Company. General catalogue

3 - Protection components Motor circuit-breakers

EAD10H80D EAD14H80D EAD17H80D

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Protection components

RESIDUAL CURRENT CIRCUIT BREAKER

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

l Suitable for most residential, commercial and light industrial applications

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Phase + Neutral, neutral on right side

RX 3 M.C.B A up to 63 A

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

Residual current devices

RX 3 M.C.B A up to 63 A

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work

BETA Switching Switches and Light Indicators

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Effective discrimination of protective devices

DX³ RCBO 6000 A Phase + Neutral, neutral right side

MCBs and RCDs LR TM 6000

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DMX 3 -I 2500 switch disconnectors

Breaking and protection devices

Unit price (incl.vat) in VND Domae MCB - 1P/1P+N, 4.5kA & 6kA, 230/240V Domae MCB 1P. 4.5kA Reference 112, DOM , DOM11341

Perfection that Matters

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

TX³ RCCBs 2P up to 100 A

Technical catalogue. System pro M. Residual current devices 2CSC420001D0201

Cat N 3. OVERALL DIMENSIONS

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

DPX 630 Electronic release

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

01 Spectra Plus - Introduction

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

DX³ RCBO 6000A Phase + Neutral, neutral on left

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Electrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices

Phase + Neutral, neutral on left side

Acti 9 the efficiency you deserve

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

Miniature circuit 3.2 breakers 6kA type B SP. Miniature circuit 3.3 breakers curve B,C&D 10kA and 15kA. Protection Devices

ic60a circuit breakers (curve C)

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

(1,5 modules per pole)

Main catalogue. Distribution Innovation

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

DRX 125 Circuit breaker (not adjustable)

Modular contactors and relays

Transcription:

Contents Miniature circuit breakers ic60n miniature circuit breakers 6kA, C curve, 6-63A ic60h miniature circuit breakers 10kA, C curve, 6-63A ic60n miniature circuit breakers 6kA, B curve, 6-63A ic60h miniature circuit breakers 10kA, B curve, 6-63A C68N miniature circuit breakers 6kA, C curve, 6-63A C68N miniature circuit breakers 6kA, B curve, 6-63A C120N miniature circuit breakers 10kA, C curve, 80-125A Electrical auxiliaries & accessories Residual current devices ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi Command control devices isw power switches PRF1, PRD 1 & iprd surge arresters PF surge arresters itl, itlc, itlm, itls impulse relays, changeover relays & auxiliaries Enclosures MCB boards technical specifications Multipact MCB boards Multipact MCB boards/accessories

A9F74116 A9F74220 A9F74316 Type Wid. in mod. of 9mm Rated current 1-pole 2 6 A9F74106 1 10 A9F74110 16 A9F74116 20 A9F74120 25 A9F74125 32 A9F74132 40 A9F74140 2 50 A9F74150 63 A9F74163 2-pole 4 6 A9F74206 1 3 10 A9F74210 16 A9F74216 20 A9F74220 25 A9F74225 32 A9F74232 40 A9F74240 2 4 50 A9F74 63 A9F74263 3-pole 6 6 A9F74306 10 A9F74310 1 3 5 16 A9F74316 20 A9F74320 25 A9F74325 32 A9F74332 40 A9F74340 2 4 6 50 A9F74350 63 A9F74363 Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : C curve : the magnetic releases operate at 8 In ±20%; breaking capacity (IEC/EN 60947, IEC/EN 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) 6-63 1-pole 240-415 6 2/3-pole 415 6 limitation class : 3; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole 125 375 connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC/EN 60947, IEC/EN 60898. ± 6-63 1 240-415 6 2/3 415 6 1 2 3 125 375 2

A9F84116 A9F84220 61066 A9F84316 61077 Type Wid. in mod. of 9mm Rated current 1-pole 2 6 A9F84106 1 10 A9F84110 16 A9F84116 20 A9F84120 25 A9F84125 32 A9F84132 40 A9F84140 2 50 A9F84150 63 A9F84163 2-pole 4 6 A9F84206 1 3 10 A9F84210 16 A9F84216 20 A9F84220 25 A9F84225 32 A9F84232 40 A9F84240 2 4 50 A9F84 63 A9F84263 3-pole 6 6 A9F84306 10 A9F84310 1 3 5 16 A9F84316 20 A9F84320 25 A9F84325 32 A9F84332 40 A9F84340 2 4 6 50 A9F84350 63 A9F84363 Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : C curve : the magnetic releases operate at 8 In ±20%; breaking capacity (IEC/EN 60947, IEC/EN 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) 6-63 1-pole 240-415 10 2/3-pole 415 10 limitation class : 3; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole 125 375 connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC/EN 60947, IEC/EN 60898. In ± 6-63 1 240-415 10 2/3 415 10 1 2 3 125 375 3

A9F73116 A9F73216 A9F73316 Type Wid. in mod. of 9mm Rated current 1-pole 2 6 A9F73106 1 10 A9F73110 16 A9F73116 20 A9F73120 25 A9F73125 32 A9F73132 40 A9F73140 2 50 A9F73150 63 A9F73163 2-pole 4 6 A9F73206 1 3 10 A9F73210 16 A9F73216 20 A9F73220 25 A9F73225 32 A9F73232 40 A9F73240 2 4 50 A9F73 63 A9F73263 3-pole 6 6 A9F73306 10 A9F73310 1 3 5 16 A9F73316 20 A9F73320 25 A9F73325 32 A9F73332 40 A9F73340 2 4 6 50 A9F73350 63 A9F73363 Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : B curve : the magnetic releases operate at 4 In ±20%; breaking capacity (IEC/EN 60947, IEC/EN 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) 6-63 1-pole 240-415 6 2/3-pole 415 6 limitation class : 3; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole 125 375 connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC/EN 60947, IEC/EN 60898. ±20% 6-63 1 240-415 6 2/3 415 6 1 2 3 125 375 4

A9F83116 A9F83210 A9F83320 Type Wid. in mod. of 9mm Rated current 1-pole 2 6 A9F83106 10 A9F83110 16 A9F83116 20 A9F83120 25 A9F83125 32 A9F83132 40 A9F83140 50 A9F83150 63 A9F83163 2-pole 4 6 A9F83206 10 A9F83210 16 A9F83216 20 A9F83220 25 A9F83225 32 A9F83232 40 A9F83240 50 A9F83 63 A9F83263 3-pole 6 6 A9F83306 10 A9F83310 16 A9F83316 20 A9F83320 25 A9F83325 32 A9F83332 40 A9F83340 50 A9F83350 63 A9F83363 Remarks : of 4-pole, C or D curves circuit breaker can be provided upon request. Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : B curve : the magnetic releases operate at 4 In ±20% ; breaking capacity (IEC/EN 60947, IEC/EN 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) 6-63 1-pole 230-400 10 2/3-pole 400-415 10 positive contact indication; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole 125 375 connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC/EN 60947, IEC/EN 60898. ±20% 6-63 1 230-400 10 2/3 400-415 10 1 2 3 125 375 5

61005 61018 61029 Type Wid. in mod. of 9mm Rated current 1-pole 2 6 61003 1 10 61004 16 61005 20 61006 25 61007 32 61008 40 61009 2 50 61010 63 61011 2-pole 4 6 61015 1 3 10 61016 16 61017 20 61018 25 61019 32 61020 40 61021 2 4 50 61022 63 61023 3-pole 6 6 61027 10 61028 1 3 5 16 61029 20 61030 25 61031 32 61032 40 61033 2 4 6 50 61034 63 61035 t (s) 10000 5000 1H 2000 1000 500 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 0.002 0.001 0.5 1 2 3 4 5 7 10 20 30 5070100 200 I/In Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : C curve : the magnetic releases operate between 5 and 10 In; breaking capacity (IEC 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) 6-63 1-pole 240-415 6 2/3-pole 415 6 limitation class : 3; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole 110 220 340 connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC 60898. 6-63 1 240-415 6 2/3 415 6 1 2 3 110 220 340 6

61262 61271 61280 Type Wid. in mod. of 9mm Rated current 1-pole 2 6 61260 1 10 61261 16 61262 20 61263 25 61264 32 61265 40 61266 2 50 61267 63 61268 2-pole 4 6 61269 1 3 10 61270 16 61271 20 61272 25 61273 32 61274 40 61275 2 4 50 61276 63 61277 3-pole 6 6 61278 10 61279 1 3 5 16 61280 20 61281 25 61282 32 61283 40 61284 2 4 6 50 61285 63 61286 Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : B curve : the magnetic releases operate between 3 and 5 In; breaking capacity (IEC 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) 6-63 1-pole 240-415 6 2/3-pole 415 6 limitation class : 3; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole 110 220 340 connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC 60898. 6-63 1 240-415 6 2/3 415 6 1 2 3 110 220 340 7

A9N18359 Type Wid. in mod. of 9mm Rated current 1-pole 3 80 A9N18357 100 A9N18358 125 A9N18359 2-pole 6 80 A9N18361 100 A9N18362 125 A9N18363 3-pole 9 80 A9N18365 100 A9N18367 125 A9N18369 rated current : 80-125A; tripping characteristics : C curve : the magnetic releases operate between 5 and 10 In; breaking capacity (IEC 60898) : 10kA; limitation class : 3; number of operating cycles (O-C) : 5000; connections : 35mm 2 flexible cable or 50mm 2 rigid cables; complies with IEC 60898 & IEC 60947-2. A9N18369 Electrical Auxiliaries Type Wid. in mod. of 9mm Voltage V AC V DC imx + OF 2 100-415 110-130 A9A26946 shunt trip release 2 48 48 A9A26947 2 12-24 12-24 A9A26948 imn undervoltage release instantaneous 2 220-240 A9A26960 iof contact auxiliary 1 24-415 24-130 A9A26924 isd fault indicating switch 1 24-415 24-130 A9A26927 iof + SD/OF changeover 1 24-415 24-130 A9A26929 Electrical Auxiliaries Auxiliaries enable remote tripping or remote indication of the ON/OFF position of a miniature circuit breaker. They are mounted by clipping on the left hand side of the same circuit breaker with: maximum of 3 indication auxiliaries iof, isd; maximum of 2 changeover contacts (iof + SD/OF); maximum of 1 iof + SD/OF changeover contact and 1 indication auxiliary iof or isd; maximum of 2 tripping auxiliaries (imx + OF, imx, imn) Accessories Type 27005 Extended rotary handle (mounted on door or hinged panel) ic60 padlock device (bag of 2 pcs) A9A27005 A9A26970 26970 8

A9D61816 6 30 Type C A A9D61806 10 30 Type C A A9D61810 16 30 Type C A A9D61816 20 30 Type C A A9D61820 32 30 Type C A A9D61832 40 30 Type C A A9D61840 45 30 Type C A A9D61845 Application Protection and control circuits against overloads, short circuits and earth leakage faults in commercial, industrial and household's electrical distribution systems. The RCBO provides : protection against indirect contact; complementary protection against direct contact (16th Edition 412-06); rated voltage : 240V; operating voltage : 50-253V; rated current : 6-45A; tripping characteristics (BS EN 60898) : C curve : the magnetic releases operate between 5 and 10 In; breaking capacity : BS EN 60898 6kA; limitation class : 3; lockable in "ON" or "OFF" position; trip free mechanism; complies with BS EN 61009, IEC 1009; test button operates between 0.85-1.1 times rate voltage. 70mm 20mm 110mm 18mm 9

A9D11806 6 30 Type C A A9D11806 10 30 Type C A A9D11810 16 30 Type C A A9D11816 20 30 Type C A A9D11820 32 30 Type C A A9D11832 40 30 Type C A A9D11840 45 30 Type C A A9D11845 110mm 18mm 70mm 20mm Application Protection and control circuits against overloads, short circuits and earth leakage faults in commercial, industrial and household's electrical distribution systems. The RCBO provides : protection against indirect contact; complementary protection against direct contact (16th Edition 412-06); rated voltage : 240V; operating voltage : 50-253V; rated current : 6-45A; tripping characteristics (BS EN 60898) : C curve : the magnetic releases operate between 5 and 10 In; breaking capacity : BS EN 60898 10kA; limitation class : 3; lockable in "ON" or "OFF" position; trip free mechanism; complies with BS EN 61009, IEC 1009; test button operates between 0.85-1.1 times rate voltage. 10

A9R71263 A9R74463 Type Wid. in mod. of 9mm Rated current Sensitivity 2-pole 4 25 30 A9R71225 300 A9R74225 40 30 A9R71240 300 A9R74240 63 30 A9R71263 300 A9R74263 4-pole 8 25 30 A9R71425 300 A9R74425 40 30 A9R71440 300 A9R74440 63 30 A9R71463 300 A9R74463 Application The iid residual current devices provide the functions of isolation, switching and earth leakage protection of electrical circuits. They have a residual current operated electromechanical release which operates without any auxiliary source of supply to open a circuit automatically in the case of an earth leakage fault between phase and earth greater than or equal to a threshold of 10, 30, 100, 300 or 500mA. rated current : 25-100A; rated voltage : 2-pole : 230-240V, 4-pole : 400-415V; unwanted tripping : all iid/rccb incorporate a filter device preventing the risks of unwanted tripping due to transient voltages (lightning, line disturbances on other equipment) and transient currents (from high capacitive circuit); isolation and switching; positive contact indications : in accordance with 15th edition of the IEE Wiring Regulations (Regs 537-5, 537-9); operating temperature : -5 to +60 ; connections : tunnel terminals for 25mm 2 fiexible cables or 35mm 2 for rigid cables; number of operating cycles (O-C) : 20000; tropicalization : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 2-pole 4-pole 210 370 RCD : BS 4293 : 1983, CEE 27, BS EN 60898, IEC 1008, EN 61008; CEE 27 range : NF-USE, KEMA, OVE, SEMKO, DEMKO, NEMKO, FI; BS range : ASTA. 2 4 210 370 11

A9D31606 Type Wid. in mod. of 9mm C curve / C 1P + N 4 Rated current 6 10 16 20 25 32 40 Sensitivity 30 30 30 30 30 30 30 A9D31606 A9D31610 A9D31616 A9D31620 A9D31625 A9D31632 A9D31640 Function ; carries out complete protection of final circuits (overcurrents and insulation faults): protection of persons against indirect contact (30 or 300mA), protection of installations against fire hazards (300mA), additional protection of persons against direct contact (30 ma); ; voltage rating : 230 V AC; breaking capacity : EN 60898/EN 61009 : - rated breaking capacity (Icn) : 6 ka ratings : 4-40A at 30 ; fast closing; positive contact indication; earth fault visualised on front face; durability (O-C cycles) : mechanical : 20000, electrical : I 20 A : 20000, I 25 A : 10000 environment : tropicalisation : treatment 2 (relative humidity: 95% at 55 ); weight : 125g; connection : tunnel terminals for 10 mm 2 flexible or 16 mm 2 rigid cable; approvals : KEMA KEUR C curve tripping curve : the magnetic trip units operate between 5 and 10 In C curve / C 12

A9S65240 A9S65340 Type 1-pole 2-pole 3-pole 4-pole Wid. in mod. of 9mm 2 2 2 4 4 4 6 6 6 8 8 8 Rated Current!" #$ %""!" #$ %""!" #$ %""!" #$ %"" Voltage 415 415 415 415 415 415 415 415 415 A9S65140 A9S65163 A9S65191 A9S65240 A9S65263 A9S65291 A9S65340 A9S65363 A9S65391 A9S65440 A9S65463 A9S65491 Function on-load opening and closing of a circuit. positive contact indication; DC use : 48V (110V two serial poles); mechanical endurance : I=40-100A: 50000 cycles, electrical endurance : AC22 p.f.=0.6, I=40, 63A : 20000 cycles, I=100A : 10000 cycles, rated short-time withstand : 20 x ln : 1 sec; tropicalization : treatment 2 (95% relative humidity at 55 ); connections : tunnel terminals for the following cables 50mm 2 rigid cables for 40-100A, 35mm 2 flexible cables for 40-100A; complies with IEC 60947-3 standard for 40-100A; approvals : USE; utilization category : AC22A. 13

16332 1-pole + N 3-pole + N PRF1 12.5r PRD1 25r PRF1 12 PRD1 25r 230 230 230/400 230/400 50 40 50 40 1.5 1.5 1.5 1.5 12.5/100 (N-PE) 25/100 (N-PE) 12.5/100 (N-PE) 25/100 (N-PE) 1-pole + N 3-pole + N PRD1 Master 230 PRD1 Master 230/400 --- --- 1.5 1.5 25/100 (N-PE) 25/100 (N-PE) 16632 16330 16634 16332 16361 16363 PRF1 Function PRF1 Type 1 surge arresters protect electrical installations against direct lightning strokes. It is recommended for electrical installations in buildings protected by a lightning conductor. PRF1 type 1 surge arresters are tested under shock current (Iimp) with a 10/350!s wave form. "1!s; PRD Functions PRD Removable Type 2 surge arresters protect electrical installations against indirect lightning strokes. PRD surge arresters are tested under full discharge current (Imax) with a 8/20!s wave form. 16333 16557 1-pole + N 1+ 3-pole + N 3+ PRD 65r PRD 40r PRD 40 PRD 20r PRD 20 PRD 8r PRD 65r PRD 40r PRD 40 PRD 20r PRD 20 PRD 8r!s 65 40 40 20 20 8 65 40 40 20 20 8 Yes Yes No Yes No Yes Yes Yes No Yes No Yes 1.5 1.3 1.3 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 16557 16562 16567 16672 16572 16677 16559 16564 16569 16674 16574 16679, ; "25 ns.!s "1!s 16559 C65-340 C40-340 C20-340 C8-340 C neutral C1 Master-350 C1 Neutral-350 C1 25-350 C2 40-350 PRD65r PRD40, PRD40r PRD20, PRD20r PRD8, PRD8r All PRD PRD1 Master PRD1 Master, PRD1 25r PRD1 25r PRD1 25r 16681 16685 16687 16689 16691 16314 16317 16315 16316!s "25 ns 16691 14

15684 1-pole + N 1+ 3-pole + N 3+ PF 65 PF 40 PF 20 PF 65r PF 65 PF 40r PF 40 PF 20!s 65 40 20 65 65 40 40 20 No No No Yes No Yes No No 1.4 1.4 1.2 1.4 1.4 1.4 1.4 1.2 15684 15687 15692 15685 15586 15690 15688 15693!s wave form "25 ns!s 15586 " 15

A9C30812 A9C30115 A9C32316 Type Wid. in mod. of 9mm Coil voltage V AC V DC itl 16A Impulse Relays 1-pole 2 230-240 110 A9C30811 2 130 48 A9C30311 2-pole 2 230-240 110 A9C30812 2 130 48 A9C30312 2 48 24 A9C30212 2 24 12 A9C30112 2 12 6 A9C30012 3-pole 2 + 2 230-240 110 A9C30811+ A9C32816 2 + 2 130 48 A9C30311+ A9C32316 2 + 2 48 24 A9C30211+ A9C32216 2 + 2 24 12 A9C30111+ A9C32116 4-pole 2 + 2 230-240 110 A9C30812+ A9C32816 itli 16A Changeover Relays 1-pole 2 24 12 15503 itl 32A Impulse Relays 1-pole 2 230-240 110 A9C30831 2-pole 2 + 2 230-240 110 A9C30831+ A9C32836 3-pole 2 + 4 230-240 110 A9C30831+ (2 x A9C32836) 4-pole 2 + 6 230-240 110 A9C30831+ (3 x A9C32836) ietl 16A Extensions ietl 2 130 48 A9C32316 2 48 24 A9C32216 2 24 12 A9C32116 2 12 6 A9C32016 ietl 32A Extensions ietl 2 230-240 110 A9C32836 itlc 16A Impulse Relays 1-pole 2 24 A9C33111 2 48 A9C33211 2 230-240 A9C33811 Type Coil voltage V AC V DC Add-on Auxiliaries iatls Indication iatlm Latched Order Control iatlz Control by Pushbuttons iatlc+c Multi-level Control Function impulse relays allow circuit remote control : via impulse orders (mechanically latched); from several control points; impulse relays are used for the control of resistive circuits (incandescent lamps, low voltage halogen lamps, convectors) and inductive circuits (fluorescent tubes, discharge lamps). impulse duration : 50ms; maximum switching frequency : 5 operations/minute; operating temperature : -20 to +50 ; tropicalization : treatment 2 (relative humidity 95% at +55 ); switching noise level : < 60dBA (at 1 m). 16

SPN MCB/RCBO Boards & Consumer Units Bar Ratings B10006R. No. of way Dimensions H W D B10006R B10008R B10010R B10012R B10014R B10016R B10202R B10303R B10044R B10084R B10104R B10106R 6 8 10 12 14 16 2 + 2 3 + 3 4 + 4 8 + 4 10 + 4 10 + 6 90 90 300 90 350 90 400 90 450 90 300 300 400 450 450 90 90 90 90 90 90 17

Multipact Bar Ratings w/o Main Switch Space B11006R No. of way Dimensions H W D B11004R B11006R B11008R B11010R B11012R B11014R B11016R 4 6 8 10 12 14 16 420 440 110 474 440 110 528 440 110 582 440 110 636 440 110 690 440 110 744 440 110 TPN MCB/RCBO Board Bar Ratings c/w Main Switch Space B12106R No. of way To fit M/S Dimensions H W D B12104R B12106R B12108R B12110R B12112R B12114R B12116R B12118R B12120R B12122R B12112RM160 B12114RM160 B12116RM160 B12118RM160 B12112RM B12114RM B12116RM B12118RM 4 6 8 10 12 14 16 18 20 22 12 14 16 18 12 14 16 18 160 160 160 160 466 440 110 520 440 110 574 440 110 628 440 110 682 440 110 736 440 110 790 440 110 844 898 952 732 786 840 894 797 851 905 959 440 440 440 440 440 440 440 440 440 440 440 110 110 110 110 110 110 110 120 120 120 120 B12112RM160 Bar Ratings c/w Main Switch & RCD Spaces B13206 (B11... /B12... /B13... boards) ; ;. No. of way Dimensions H W D B13202 B13204 B13206 B13208 B13210 B13212 B13404 B13406 B13408 B13410 B13412 B13414 B13416 B13418 B13606 B13608 B13610 B13612 B13614 B13616 B13808 B13810 B13812 B13814 2 + 2 2 + 4 2 + 6 2 + 8 2 + 10 2 + 12 4 + 4 4 + 6 4 + 8 4 + 10 4 + 12 4 + 14 4 + 16 4 + 18 6 + 6 6 + 8 6 + 10 6 + 12 6 + 14 6 + 16 8 + 8 8 + 10 8 + 12 8 + 14 534 440 110 588 440 110 642 440 110 696 440 110 750 440 110 804 440 110 642 440 110 696 440 110 750 440 110 804 440 110 858 440 110 912 440 110 966 440 110 1020 440 110 750 440 110 804 440 110 858 440 110 912 440 110 966 440 110 1020 440 110 858 440 110 912 440 110 966 440 110 1020 440 110 18

Bar Ratings c/w Main Switch Space B17112R No. of way To fit M/S Dimensions H W D B17104R B17106R B17108R B17110R B17112R B17114R B17116R B17118R B17120R B17122R 4 6 8 10 12 14 16 18 20 22 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 456 510 564 618 672 726 780 834 888 942 405 405 405 405 405 405 405 405 405 405 105 105 105 105 105 105 105 105 105 105 No. of way Dimensions H W D B14006 B14004 B14001 B14003 B14004 B14006 B14008 B14010 B14012 B14014 B14016 1 x 4P 3 x 4P 4 x 4P 6 x 4P 8 x 4P 10 x 4P 12 x 4P 14 x 4P 16 x 4P 200 150 70 200 300 70 200 400 70 300 440 110 380 440 110 450 440 110 530 440 110 600 440 110 670 440 110 B15160 Application Dimensions H W D B15160 INS 125-160 350 440 90 B15 INS 400 440 90 Bar Ratings w/o Main Switch Space B16304 B16206 No. of way Dimensions H W D B16206 6 x 2P 387 440 110 B16208 8 x 2P 423 440 110 B16212 12 x 2P 495 440 110 B16304 4 x 3P + N 423 440 110 B16306 6 x 3P + N 495 440 110 B16308 8 x 3P + N 567 440 110 19 B19001 B19002 B19001 B19002 100A AI switch tee busbar Blanking plate for 6 SP MCB Description

Schneider Electric (HK) Ltd. 13th Floor, East Wing, Warwick House, Taikoo Place, 979 King's Road, Quarry Bay, Hong Kong SEHK/DOC/MCB16 05/2013