Fire Safety Products. Product Overview

Similar documents
DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

PKIR3G, PKIS, PKIS3G and PKIS3GA

Systemair Fire Dampers

SMOKE CONTROL DAMPERS

PKI-C Cartridge Fire Dampers

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

Systemair Fire Dampers

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

Bevent Rasch BSK6. - Fire /04/2017

Bevent Rasch BSK Fire /04/2017

Fire dampers ETCE and ETCS TECHNICAL DATA

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

7/S5 FIRE DAMPER FD40. v 2.9 (en)

ESAS Smoke control damper

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

Smoke damper EKO-SRB1

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

Rectangular fire damper TFER 30. pag. C-10

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

TYPE EK-EU SMOKE CONTROL DAMPER

Fire/smoke damper EKO-SRBG1

series CEVH Smoke Evacuation Damper

Fire/smoke damper EKO-JBG2

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

Combustion gas damper EKO-JB

M A D E L. FOK-EIS-180 Fire dampers CE

Fire Dampers Catalogue

VX-6V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of

Rectangular smoke damper (remote controlled)

Combustion gas damper EKO-SRB

lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction

Fire damper FK120/FK90 TECHNICAL DATA

table of contents PRODUCT SUMMARY 2

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Air distribution product

Fiberseal. Flexible fire protection closures. Fiberseal Evolution-Sm Fiberseal Evolution-Sa Fiberseal-H Fiberseal-S

Rectangular smoke damper (remote controlled)

ACCESSORIES FOR DUCT FANS

VU120. Rectangular smoke evacuation damper. V22-EN-G 08/2017

Fire Damper BSK-RPR. with general building supervisory approval Z

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

Air Zone. High Care. Cleanroom Filtration

The VX-6 smoke control dampers are designed for smoke control systems in buildings outfitted with a one-stage

Type VSD35. Nominal length up to 1500 mm: one spigot

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Cleanroom Filtration

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

Slot diffusers for ceiling installation

Volume Flow Limiters Type VFL

PERFORMANCE SPECIFICATIONS SINGLE-SPEED, 110 CFM VENTILATION FAN

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Slot diffusers, Round duct diffusers. IMP Klima

LOUVERED FACE GRILLES AND REGISTERS

SMOKE EXTRACTION VENTILATION FOR PARKING PREMISES

Cleanroom Filtration

Mechanical mixing box MBM

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

Directive ErP 125 and Fans by Systemair

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

LINEAR DIFFUSERS AND BAR GRILLES

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Fire/combustion gas damper EKO-JBL

Motorized Fire Dampers

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

TECHNICAL-OPERATIONAL DOCUMENTATION. FIRE SAFETY VALVES type V370 and RK370

CONSTANTFLOW Volume Flow Controllers

WhispAire Range Hood Quiet Hood

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Smoke control damper RKI-90 Test certificate Z

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75. Alsident System 100. Chemical Resistant (CR) Product Information SYSTEM 100 CR

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

VU120. Rectangular smoke evacuation damper. V22-F 07/2015

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Linear Floor Grilles Models FG, F20, F25 and FRO

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en)

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

High Performance Axial Fans

Fire Block and Pressed Steel Grilles

ROOFMASTER STEF-HT ROOF FAN

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

Regulation and shut-off damper SPB and SPC

Air Transfer Grilles. NS Core only grille for beading in place. NSNL Core only No-Sight

Adjustable Duct Grilles

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

IMP Klima. Swirl diffusers. Variable swirl diffusers

ROOFMASTER STEF-ATEX ROOF FAN

HIGH-POWERED VENTILATORS

Transcription:

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Fire Safety Products Product Overview

SAFETY PRODUCTS prevent the spread of toxic gases, smoke and fire, help with evacuation, increase the effectivness of active fire protection systems and minimize the property damage. MULTI-COMPARTMENT SMOKE EVACUATION MULTI-COMPARTMENT SMOKE AIR GRILLE EVACUATION

S Safety position: closed PKIR3G PKIS3G Circular Fire Damper DN 100 up to 1000 W H = 100 100 up to 1200 800 1396-CPR-0077 PKIR-E60S PKIS3GA Circular Fire Damper DN 100 up to 630 1396-CPD-0069 800 < W 1200 & 100 H 300 1396-CPR-0077 PKI-C PKIS-S Cartridge Fire Damper DN 100 up to 200 1396-CPD-0050 W > 1200 and/or H > 800 up to 1600 1000 1396-CPD-0062 PKIS-S W > 1200 and/or H > 800 up to 1600 1000 1396-CPD-0062 * Detailed information about fire resistivity is on the back page.

SMOKE S Safety position: open or closed DKIS1 Single-compartment Rectangular Smoke Damper W H = 200 200 up to 1500 800 DKIR1 Single-compartment Circular Smoke Damper DN 100 up to 630 1396-CPR-0058 1396-CPD-0058 DKISMA Multi-compartment Smoke Damper W H = 200 200 up to 1600 1000 1396-CPR-0112 EKIR-E60S Circular Evacuation Damper DN 100 up to 630 EVACUATION S Safety position: open 1396-CPD-0069 FGS Fire Air Grille 800 1000 AIR GRILLES Safety position: closed * Detailed information about fire resistivity is on the back page.

Product type Dimensions range (mm) Fire resistivity Supporting construction Installation - tested at underpressure (Pa) Wet Dry Soft crossing Instal. kit On a wall Out of a wall ve 500 300 300 500 300 W 300 W 100 DN 400 ve 500 300 300 500 300 W 300 W ve 500 500 ve 500 300 300 500 300 W 300 W PKIR3G 400 < DN 630 ve 500 300 300 500 ve 500 500 ve 500 300 630 < DN 1000 ve 500 300 ve 500 PKIR-E60S DN 100 up to 630 PKI-C DN 100 up to 200 E60 ve 300 NOINS 300 NOINS ho 300 NOINS 300 NOINS ve 300 300 ho 300 ve 300 300 ho 300 ve 300 300 ho 300 ve 500 300 300 500 KIT 300 W, P 300 W, P PKIS3G 100 100 up to 1200 800 ve 500 300 300 500 KIT 300 W, P 300 W, P ve 500 500 KIT 300i o W, P 300i o W, P 300 PKIS3GA 800 < W 1200 & 100 H 300 ve 300 300 P 300 P ho ve 300 300 P 300 P ho PKIS-S MULTI, PKIS-S W > 1200 and/or H > 800 up to 1600 1000 ve 300 300 300 300 W 300 W ho 300 300 300 ve 300 ho 300 300 FGS 800 1000 S a, S a * ve S a = 33 m 3 / (hm 2 ) at 50 Pa S a = 33 m 3 / (hm 2 ) at 50 Pa DKIR1 DN 100 up to 630 E 600 120 (v ed i o) S500 C 10000 AA single ve 500 DKIS1 1500 800 E 600 120 (v ed i o) S1500 C 10000 AA single ** ve 500 & 1500 ** DKISMA 1600 1000 (v ew i o) S1500 C mod AA multi ve 1500 EKIR-E60S DN 100 up to 630 E60 ve 300 NOINS 300 NOINS ho 300 NOINS 300 NOINS www.systemair.com

Legend RIGID/FLEXIBLE WALL ONLY RIGID WALL/CEILING ONLY IN/ON THE DUCT MULTI KIT All fire dampers are designed for explosion hazardous areas classified as Multi-installation in a wall: multiple neighbouring dampers always aligned horizontally and/or vertically with blade axis in horizontal orientation Up to dimensions W H = 800 600 mm only * The FGS has resistivity S a in the upper part & S a in the lower part of a vertical building element according to ETAG 026 Part 4 art. 2.4.2.1 par. 6 ** DKIS1 has resistivity E 600 120(v ed i o)s500 C 10000 AA single, for dimensions bigger than W H = 1200 800 mm P W NOINS Installation on a wall or out of a wall with Promatect boards insulation for lower ceilings with resistivity EI30/45/60/90S; all PKIS3G and PKIS3GA up to dimensions W H = 800 600 mm only Installation on a wall or out of a wall with mineral wool insulation, installation with S up to DN = 400 mm, installation with S up to DN = 500 mm Installation on a wall or out of a wall without insulation The tightness of the blade and the casing according to EN 1751: - 3C for PKIR3G as standard - 2C for other fire damper types as standard - 3C for other fire damper types for extra charge Modulated fire dampers (the activation mechanism DV9-T-SR) are manufactured: - PKIR3G with DN 160 mm - PKIR-E60S in all dimensions - PKIS3G with H 160 mm E8283. IMOS-Systemair. Maart 2018 GOOD TO KNOW Current information on all fire safety products are available at www.systemair.com/fspoverview