Re.Formance Line INSTRUCTION MANUAL 1703

Similar documents
User Manual Operator chair Carl Mk2

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

VELA Tango 100, 100EL, 200 & 200EL USER MANUAL VARIANT: Manual no VELA Tango 200El. Arthrodesis VELA Tango 100 VELA Tango 200

Nimbo Lightweight Posterior Posture Walker

User guide Operator chair Carl Carl Foot and Carl Heel

Mod: KLD6-12/35XLAS-N

VELA Tango for children

USER MANUAL PRODUCT CODE: WC CareCo (UK) Ltd, Hubert Road, Brentwood, Essex, CM14 4JE PAGE 1

USER MANUAL. VELA Samba 100/110/120/130/150 VARIANT: Manual no VELA Samba 100 VELA Samba 110. VELA Samba 150

Dealer Stamp. Rollator (R6 and R8) Assembly & Operating Instructions

User manual Patient chair Malin

ACROBAT SWING STAND MODEL

STRETCHERS PT1000 SERIES

OPERATION and SERVICE MANUAL EC TRANS. CHAIR

Assembly & Operating Instructions

QA4 Surgery Trolley System Manual Function Operating Instructions

Owner s Manual. Bariatric Manual Wheelchairs. Specializing in Bariatric Patient Aids

Armon Edero. User manual

VELA Samba 400/410/500/510/520/530 USER MANUAL VARIANT: Manual no VELA Samba 530. VELA Samba 510. VELA Samba 520.

User manual. Model Mini, Small, Medium and Large

Heavy Duty Four Wheeled Walker

INSTRUCTION MANUAL STANDING WHEELCHAIR. KARMAN HEALTHCARE INC. City of Industry, CA

LIGHTWEIGHT TRANSPORT CHAIR ECTR 01 Assembly and Operating Instructions

PARTS DESCRIPTION. Restwell Venice Massage Chair (MC006) Owner s Handbook

Aluminium 4-Wheeled Rollator/ Occassional Transport Chair VP184 Range Usage and Maintenance Instructions

ACTIVE SEAT SYSTEM. General User/ Safety Guide. ACTIVE CUSHIONS

User Instructions Shower and Commode Wheel Chairs

Instruction manual. RP800 - HYDRAULIC actuator, load 150Kg. RP815 - LINAK actuator, load 150Kg

Mobile Shower Commode Chair

User Manual SONESTA S2 & S3

Office Seating. Instructions for Use G

Mobile Shower Commode Chair

Aston Shower Commode Chair Owner s Handbook

COBRA Indoor base with gas pressure spring and 45 tilt function user manual

Aston Shower Commode Chair Owner s Handbook

Air terminal devices

Apollo Tilt Wheelchair 18" and 20" Instruction Manual

EXTRA WIDE STEEL ROLLATOR

IMPORTANT. OPERATION INFORMATION l DO

PNEUMATIC PUMP Series

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

RESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK PARTS DESCRIPTION

2 in 1 Rollator and Transit Chair M58203

BERYL SLIDE AND SWING OWNER'S MANUAL

Self-propelling Shower and Commode Wheel chairs

Instructions for use. PHYSIO Evo/Evo F/One

ACROBAT SWING STAND MODEL

KidWalk KidWalk II Dynamic Mobility System

Turner PRO. User manual. BM61099 Rev B

Push Down Wheeled Walker

The Esteem Steel Self Propel Wheelchair Instructions

BEL-50N DENTAL CHAIR OPERATING INSTRUCTIONS IMPORTANT

Enigma Travel Chair and Lightweight Aluminium Wheelchair Owner s Handbook

Rev ENGLISH..2

Transit Wheelchair. user guide. Profiled grip attendant handles. Padded seat and backrest. Lift up, padded armrests. Park brakes

USER MANUAL. CareCo (UK) Ltd, Hubert Road, Brentwood, Essex, CM14 4JE PAGE 1 PRODUCT CODE WC01060.BLU

OWNER S MANUAL. Manufactured & Distributed by. Transfer Wheelchair

Commode Mod. VC 100 Commode Mod. VC 200 Cod Cod Commode Mod. VC 400 Commode Mod. VC 500 Cod Cod.

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

ASSIST & TRANSIT. osd USER MANUAL TABLE OF CONTENTS

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

AIM LED LIGHT (wall mount)

1.3. Unpacking the chair... 4

TNK FLEX By Alegre Studio

MINOS GLOBAL ALU User Manual

Mighty Mack Wheeled Walker

Euro Lightweight Wheeled Walker

SERVICE MANUAL

ERGONOMIC SEATING PROGRAM

Double piston rotary drive DRQD-6/... / b [ ] (en) Operating instructions

ASSIST & TRANSIT. osd USER MANUAL TABLE OF CONTENTS

and USER MANUAL PRODUCT CODES SELF PROPELLED WC01061 TRANSIT WC02059 CareCo (UK) Ltd, Hubert Road, Brentwood, Essex, CM14 4JE PAGE 1

CARROZZINA ESSEX ESSEX WHEELCHAIR FAUTEUIL ROULANT ESSEX SILLA DE RUEDAS ESSEX

ENIGMA SUPER DELUXE WHEELCHAIR

Usage of GTM 1 and GTM HAMMER VARIO

SERVICE MANUAL US. Permobil M300/M400. Power Wheelchair

STAND MODEL FOR MACH M2

Petite Wheeled Walker

Kidslover Disabled Child Car Seat

Invacare. Battery Charger User Manual. Model: POC1 115, POC1 115 AZ, POC1 115 C, POC1 115 EU

912/913/916/4912/4913/ /923/926/4922/4923/

OPERATION MANUAL HARVEST ROYAL

OPERATION MANUAL HARVEST CAVALIER

A chair that is as individual as you yourself. Whether mobile or static, it is always comfortable. Sedus black dot s many features enable it to adapt

Tri-Wheel Wheeled Walker

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

SB2 TubBuddy Owners Manual. elimination through innovation

Tiller Lock Assembly

Emergency Power Supply for the OMEGA ACTIVE-System. Operating Instructions

Rev Miniature / Miniature K. Silent Power Evo 2 / 2L / 4L / 4LK / ENGLISH...2

Requests for Daily Care and Maintenance

SIGMA. User Manual MB8100GB

Requests for Daily Care and Maintenance

AIM LED LIGHT (ceiling mount)

Absolutely unique: The new Sedus Similar-Plus mechanism.

Angle Grinder Holder

Operation & Maintenance Manual. Sludge Vac. Visit our Website for more information on this product.

1416 Cabinet Unit. Installation Operation Maintenance Troubleshooting Version Dec/17

SHELL CHAIR USER MANUAL

Transcription:

Re.Formance Line INSTRUCTION MANUAL 1703 320.8779.02 / 1703

Re.Formance Line Table of contents 1. Overview... 3 1.1 Re.Forma Hi.... 3 1.2 Re.Forma... 3 1.3 Re.Forma Lite.... 3 2. Notes... 4 2.1 Warranty / Liability... 4 2.2 General information... 4 3. Introduction... 4 3.1 Definitions... 4 3.2 General warning... 4 3.3 Documentation purpose... 5 3.4 Responsibility limitations... 5 3.5 Transport and storage... 5 3.6 Packing disposal... 5 3.7 Working chair disposal... 5 4. Equipment description... 6 4.1 Intended use... 6 4.2 Warranty... 6 4.3 Identification and labelling... 6 4.4 General features... 7 4.5 Technical specifications... 7 5. Installation... 8 5.1 Supply status... 8 5.2 Unpacking... 8 6. Using the product... 8 6.1 Model Re.Forma... 8 6.2 Model Re.Forma Lite.... 9 6.3 Model Re.Forma Hi.... 9 7. Maintenance... 10 7.1 Cleaning... 10 8. Accessories... 11 8.1 Castors... 11 8.2 Footrest ring... 11 8.3 Seat adjustment with foot plate control... 11 8.4 Gas spring with different height ranges... 11 2

1. Overview 1.1 Re.Forma Hi. Seat Lever Base Castor 1.2 Re.Forma Backrest Seat Lever Base Castor 1.3 Re.Forma Lite. Seat Lever Base Castor 3

Re.Formance Line 2. Notes 2.1 Warranty / Liability The warranty and liability for defects shall be governed by the General Terms and Conditions of Mikrona Technologie AG as of January 2016 (GTC). The GTC can be downloaded on the website of Mikrona Technologie AG (www.mikrona.com). It is essential that this instruction manual be read by every user / operator before initially operating the working chair in order to prevent faulty operation and other damages. The warranty claims are governed by the GTC. Furthermore, it is recommended to pay attention to the recommendations and warnings within the operating and maintenance instructions. 2.2 General information This instruction manual is an integral part of the working chair. Always keep it easily accessible in close range of the product. Compliance with the operating instructions is condition to intended use and correct operation of the working chair. Instruct new employees appropriately and forward the operation manual to successors. User / operator safety and failure-free operation of the working chair is only provided when using original components. Only use accessories that are listed in the operation manual or authorized by Mikrona Technologie AG for this particular purpose. The company Mikrona Technologie AG does not warrant secure operation and function if other accessories are used. Related damages may not be claimed under this warranty. 3. Introduction 3.1 Definitions Important information in the operating instructions concerning the safety of individuals and the device are highlighted with the following terms and symbols: Note Contains important information, which should be highlighted with respect to the text. Caution / Warning Before conducting certain procedures this message may be displayed. If not observed, it could cause damage to the operator and the equipment. 3.2 General warning Upon user request, the manufacturer agrees to provide list of component parts, calibration instructions or other information available, which will assist the user s technical personnel to conduct repairs to those parts of the chair which are considered repairable by the manufacturer. 4 Warning The manufacturer will accept responsibility for the safety, reliability and performance of the equipment on the following conditions: The installation operations, modifications or repairs have been performed by authorised personnel. The equipment is utilized in accordance with the operating instructions.

3.3 Documentation purpose This manual shows the Re.Formance line working chair and contains information regarding their correct use, functions, performances, maintenance, troubleshooting and corresponding solutions. This manual is intended for the final user, the professional that uses the equipment to perform his job. 3.4 Responsibility limitations The Manufacturer must be relieved of any responsibility in the following cases: Improper use or usage by untrained personnel for professional use Lack of maintenance or servicing Unauthorized modification or interventions Use of non-original spare parts, or not model-specific Failure to comply with the instructions (even partially) Exceptional events 3.5 Transport and storage The equipment, if contained in its original packaging, may be exposed for a period of no more than 10 weeks to environmental conditions within the following ranges: Min Max Environment temperature -5 C +40 C Relative humidity (condensation included) Atmospheric pressure 10% 100% 500 hpa (mbar) 1060 hpa (mbar) 3.6 Packing disposal All materials used for packaging are recyclable and respect the environment: Cardboard box Polythene film or bubblewrap Please deliver the packing to an authorized landfill, for the recovery of these materials. 3.7 Working chair disposal Working chair disposal does not present risk of any type. For proper environmental safeguard, please deliver the working chair, now out of order, to an authorized landfill collecting recyclable and non-recyclable materials. 5

Re.Formance Line 4. Equipment description 4.1 Intended use The product described in this manual is a medical operator s working chair. It is intended to comply with the general requirements of a medical practitioner or his assistant during medical examinations or therapies (e.g. dental therapies, ENT, podiatry or gynaecology examinations). 4.2 Warranty Note Upholstery damage caused by contact with clothes or clothing accessories (e.g. belts) having metal, sharp, pointed or similar parts will not be replaced under warranty. Caution The use of disinfectants or detergents with a strong alcoholic content on the plastic components of the equipment may damage the surface of the product. 4.3 Identification and labelling The working chair identification label is found outside the working chair under the seat. Here you can find the working chair model, the serial number and other information. The figure shows the label position in the various versions and a facsimile. 6

4.4 General features This chapter offers a full view of the main features of the Re.Formance line working chair. Moreover, it shows the main working chair versions, their components and their corresponding accessories (see chapter 8). Re.Forma Re.Forma Lite Re.Forma Hi Swivelling base, black, on 5 non-braked castors Saddle seat, adjustable in height and inclination Legend Basic feature Feature not provided Optional feature Round seat, adjustable in height Symmetrical working chair, for use both on the right and on the left side of the patient chair Aluminium base, black Aluminium base, chrome-plated Seat adjustment with foot plate control Castors with friction Height adjustable footrest ring Standard gas spring Short gas spring Backrest, adjustable in height Backrest with integrated armrest 4.5 Technical specifications The Re.Formance working chairs comply with Medical Device Directive 93/42/EEC and subsequent modifications. Re.Forma Re.Forma Lite Re.Forma Hi Swivelling base, external diameter mm 600 600 600 Seat height from the floor (min.) with standard gas spring mm 545 545 500 Seat height from the floor (max.) with standard gas spring mm 745 745 750 Seat height adjustment with standard gas spring mm 200 200 200 Seat height from the floor (min.) with short gas spring mm 415 415 420 Seat height from the floor (max.) with short gas spring mm 500 500 505 Seat height adjustment with short gas spring mm 85 85 85 Seat height from the floor (min.) with standard gas spring and foot control mm 585 585 590 Seat height from the floor (max.) with standard gas spring and foot control mm 685 685 690 Seat height adjustment with standard gas spring and foot control mm 100 100 100 Seat height from the floor (min.) with short gas spring and foot control mm 525 525 530 Seat height from the floor (max.) with short gas spring and foot control mm 575 575 580 Seat height adjustment with short gas spring and foot control mm 50 50 50 Seat tilting angles deq - - -8 /+6 Seat width mm 380 380 450x350 Backrest height adjustment mm 60 - - Gross Weight kg 18 13 13 Net Weight kg 13 8 8 Safe working load kg 135 135 135 Packing dimensions mm 620x620 x940(h) 620x620 x940(h) 620x620 x940(h) 7

Re.Formance Line 5. Installation 5.1 Supply status The following elements must be contained inside the packaging: A Re.Formance line working chair An operating instruction manual In case of mistake or missing parts, contact the dealer to manage the problem. 5.2 Unpacking To remove the packing, it is necessary to remove the staples, which close the upper portion of the cardboard box. It is recommended to take the working chair out of the cardboard box by lifting it from the top, after having removed the polystyrene block, which keeps the working chair in its correct packing position. Once the plastic bag has been removed, the working chair is ready for use. 6. Using the product 6.1 Model Re.Forma Description It offers a wide circular seat adjustable in height and an ambidextrous backrest. This characteristic makes it also suitable for a medical assistant. Controls The figure shows the available controls for the Re.Forma working chair. They consist essentially in a lever (H), placed under the seat, and a knob (K) placed on the backrest. Seat height adjustment In order to adjust the working chair seat height in a comfortable way, it is recommended to sit on the working chair and use your own body weight. To lower the seat, keep pulled the lever H. The seat moves downwards under the operator s body weight. To raise the seat, keep pulled the lever H while standing up to eliminate body weight pressure on the working chair. The seat moves upwards. 8 Backrest height adjustment In order to adjust the backrest height in a comfortable way, it is recommended to operate from the back of the working chair. Grab the backrest. Press the knob K. Raise or lower the backrest to the desired position. Release the knob K.

6.2 Model Re.Forma Lite. Description The Re.Forma Lite is the simplest version among the three available ones. It offers a wide circular seat adjustable in height. Controls The figure shows the available controls for the working chair. They consist essentially in a lever (L), placed under the seat, that controls the manual movements of seat height adjustment. Seat height adjustment In order to adjust the working chair seat height in a comfortable way, it is recommended to sit on the working chair and to use your own body weight. To lower the seat, keep pulled the lever L. The seat moves downwards under the operator s body weight. To raise the seat, keep pulled the lever L while standing up to eliminate body weight pressure on the working chair. The seat moves upwards. 6.3 Model Re.Forma Hi. Description The Re.Forma Hi working chair was designed for all the practitioners that need a correct posture of the vertebral column even without a backrest supporting them. Seat tilt position adjustment allows to find a suitable working position, and relax the vertebral column by transmitting the weight directly to the legs instead of the lower back. Controls The figure shows the available controls for the working chair. They consist of 2 levers (L1 and L2), placed under the seat, that control the manual movements of the working chair itself. To adjust the working chair in the most comfortable way, it is recommended to sit on the working chair and to use your own body weight. Seat height adjustment To lower the seat, keep pulled the lever L1. The seat moves downwards under the operator s body weight. To raise the seat, keep pulled the lever L1 while standing up to eliminate body weight pressure on the working chair. The seat moves upwards. Seat tilt position adjustment To adjust the seat tilt position in the most comfortable way, it is recommended to sit on the working chair and to use your own body weight. Then, follow these instructions: Keep the lever L2 pulled. Move your body weight along the seat to find the desired position. Release the lever L2. 9

Re.Formance Line 7. Maintenance Re.Formance working chairs are made to require no maintenance during their life. Thus there are no specific adjustments to be carried out at any time. If the working chair is not used for some time, it is recommended to cover it in order to protect it against dust. Warning It is recommended to have any technical adjustment as well as any repair of the working chair carried out by specialized maintenance technicians. 7.1 Cleaning For a better and longer life of the equipment, it is necessary to perform an accurate, methodical and periodical general cleaning of the working chair. It is recommended to proceed as follows. Caution The use of disinfectants or detergents with a strong alcoholic content on the plastic components of the apparatus may damage the surface of the product. It is recommended to avoid the use of any dissolvent, strong detergent or abrasive agent, even to remove tenacious stains. Upholsteries The machined working chair upholstery has to be cleaned using a non-alcoholic disinfectant and a soft cloth to avoid any surface scratching and to guarantee a better elasticity and smoothness of the surface. Plastic or metallic parts The polyurethane parts, as well as the metal parts (painted and not painted) have to be cleaned with a soft cloth dipped in water and soap. 10

8. Accessories 8.1 Castors The working chair can be equipped with various types of castors. The basic version is provided with non-braked castors. Castors with friction Independently from other characteristics (black or chrome-plated, normal or anti-static wheels), upon request it is possible to mount castors with friction. These castors allow the working chair to move only when the operator is correctly seated on it, in order to guarantee maximum safety and prevent the working chair rolling away from the operator when sitting down. 8.2 Footrest ring Upon request at the moment of placing the order, the working chair can be equipped with a footrest ring. Such footrest helps the operator s comfort, allowing him to vary the leg position while working. The footrest has a lever that allows height adjustment. To adjust it, proceed as follows: Unscrew the knob P at the centre of the ring. Set the desired footrest height. Tighten the knob P again. 8.3 Seat adjustment with foot plate control Upon request at the moment of placing the order, the working chair can be equipped with a seat height adjustment via a foot control. In order to adjust the working chair seat height in a comfortable way, it is recommended to sit on the working chair and to use your own body weight. The footrest has a plate that allows height adjustment. To adjust it, proceed as follows: To lower the seat, keep pushed the plate P downwards by pressing on one side. The seat moves downwards under the operator s body weight. To raise the seat, keep pushed the plate P while standing up to eliminate body weight pressure on the working chair. The seat moves upwards. Caution Do not push the plate at two or more sides at the same time. When the working chairs are provided with foot control, the lever that controls seat height has no function. 8.4 Gas spring with different height ranges Re.Formance line working chairs can be equipped, upon request at the moment of placing the order, with a shortened gas spring, in order to suit the specific needs of some operators. 11

The manufacturer pursues a policy of continuous product development. Therefore, it reserves all rights to change the technical and aesthetical characteristics of the product at any time. MIKRONA TECHNOLOGIE AG Wigartestrasse 8 8957 Spreitenbach Switzerland P +41 56 418 45 45 F +41 56 418 45 00 swiss@mikrona.com www.mikrona.com