Eclipse RatioAir Burners

Similar documents
RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

Data /1/07 Eclipse RatioAir Burners Model RA0040

Eclipse RatioAir Burners


Eclipse Vortometric Burners Series HI

Capacities and Operating Data

TriOx Triple Air Staged Ultra Low NOx Burner

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110

North American 4485 Tempest SE

Design and Application Details

North American 4575 HiRAM

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Makotherm Thermal / Catalytic Oxidizer Operation and Maintenance Manual

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction

Low emissions, high performance natural gas burners

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

Design and Application Details

Eclipse Single-Ended Radiant Tube Burners

1070 SERIES ULTRA LOW NO X

VALUPAK. Packaged gas burners

LVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1

NOx-Beta Ultra Low NOx Burners

VALUPAK. Packaged gas burners

1200 SERIES FTR HOT AIR BAFFLE BURNER

KINEMAX. Medium velocity gas or oil burners

MULTIFIRE. High temperature dual fuel burner

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

G96 Series BASOTROL Dual Operator Valve

Design and Application Details

Design and Application Details

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm)

1470 SERIES HOT AIR GAS BURNER

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

PREMIX TUNNEL BURNERS

Specifications of OPTIMA SLS Burners

North American Combustion Burners

2.0 Burner Operating Parameters and Requirements

North American Combustion Burners

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

1466 SERIES COLD AIR GAS/OIL BURNER

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

LVDT/HC PILOT BURNER. External raw gas pilot burner

BBC Multi-fuel Combination Beta Burner

Mark 695 Series. Pressure Regulators Mark 695 Piloted Tank Blanketing Regulators. Piloted Tank Blanketing Regulator 3/4"- 1" Optional Features

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

Specifications of STICKTITE and PILOTPAK Nozzles

LP BURNER SERIES.

Eclipse Butterfly Valves

3/2-way Solenoid Valve for pneumatics

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

Co Gen liner upgrade project Jan 2014 Huntsman 6 B conversion to Power System Manufacturing Low emissions combustion system

Mark 608BP Series. Pressure Regulators Mark 608BP Gas Pressure Regulators. Balanced Plug Gas Pressure Regulators. Features

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

APX Nozzle-mix line burner

energy efficiency Zone valves

Biological Safety Cabinet

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB

GEMINI GAS CONTROL PRODUCT INFORMATION

2/2 or 3/2-way Miniature Rocker Solenoid Valve

Performance Selection Data

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

PRODUCT CATALOG CLASS II BIOLOGICAL SAFETY CABINET.

OT LE 600/900/1200 GAS

KG7T (E and N Series)

Assembly Numbers. For these products, please order per the following product numbers: (configured products are those with alphanumeric text)

FG7T (E and N Series)

Specifications of MAXON VALUPAK burners for 50 Hz operation

Start-up Instructions

Mark 908 Series. Pressure Regulators Mark 908X Piloted Blanketing Regulators

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

Sentronic PLUS 614 Series

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

1500 SERIES LARGE CAPACITY ULTRA 2 LOW NO X

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Economite RE Series. Power Gas Burners. MADE in the USA

Specifications of STICKTITE and PILOTPAK Nozzles

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive.

SGT-700 DLE combustion system extending the fuel flexibility

INFINITE ENERGY 2-199

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

36H Gas Control Product Information

Mark 608 Series. Pressure Regulators Mark 608 Gas Pressure Regulators. Gas Pressure Regulators. Specifications. CRN Registration Number Available

D SERIES TECHNICAL DATA INFORMATION PACKET

P200 Pressure Regulator

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

KG7T (C and L Series)

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

S1 SERIES TECHNICAL DATA INFORMATION PACKET

Transcription:

Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged Minimum input, () Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) Fuel pressure at ratio regulator inlet. High Fire Flame Length, inches (mm) Measured from the outlet end of the combustor. Maximum Flame Velocity, ft/s (m/s) Approximately 15% excess air at maximum input. Maximum chamber temperature, ºF (ºC) Alloy tube SiC tube Block & Holder Flame detection Fuel Straight Tube SPECIFICATIONS Tube Model RA0 Version 1 Tube 1,030,000 (302) 1,140,000 (334) 1,000,000 (293) 1,040,000 (306) 1,120,000 (328) 940,000 (293) 1,030,000 (302) 1,090,000 (319) 950,000 (293) 1,095,000 (321) 1,165,000 (341) 964,000 (282) 1,108,000 (324) 1,145,000 (335) 906,000 (265) 1,095,000 (321) 1,114,000 (326) 916,000 (265) 30,000 (8.8) 30,000 (8.8) 30,000 (8.8) 6 to 20 (15 to 50) 10 to 20 (25 to 50) 15 to 27 (37 to 67) 45 (1140) 38 (965) 33 (835) 1500 (816) 1900 (1038) 250 (75) 500 (150) 1750 (954) 2500 (1370) 2800 (1538) 1750 (954) 2500 (1370) 2800 (1538) UV scanner available for all combustors. Flame rod available for alloy or SiC tubes, and (For any other gas, contact Eclipse Combustion for orifice sizing.) All information is based on laboratory testing in neutral (" w.c.) chamber with standard combustor design. Different chamber conditions will affect the data. Maximum inputs are given for the standard combustion air blower without an air filter. All inputs based upon gross calorific values and standard conditions:1 atmosphere, 70º F ( 21ºC). motor service factors greater than may be required when firing into negative chamber pressure applications. For specific application questions, contact your Eclipse Combustion representative. Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. 0 Control and Operation Zone % Excess Air Typical Ratio Control Input and excess air at low fire changes with ratio regulator adjustment. 10 0 250 500 750 0 Input x 0 0 75 150 225 300 Input

Parameter Maximum Input vs. Chamber Pressure () Straight Tube Specifications Model 60Hz, 4H (3"w.c. @ 11,500 scfh, 1/3 hp) 50Hz, 4E (4.2"w.c. @ 13,700 scfh,.37 ) "w.c. - - (mbar) -5,0-2,5 0,0 5,0 Specifications 60Hz Packaged 1,300,000 1,175,000 1,030,000 875,000 680,000 381 344 302 256 199 50Hz Packaged 1,330,000 1,218,000 1,095,000 956,000 793,000 389 357 321 280 232 NOx ppm 120 80 60 40 20 NOx Emission Data 0 0 250 500 750 0 1250 Input (x 0 BTU/hr) NOx emission data is given for: Ambient combustion air ~70 F (20 C) Minimal process air velocity ppm volume dry at 3% O 2 Neutral chamber pressure CO emission is largely influenced by chamber conditions. Contact your local Eclipse Combustion representative for an estimate of CO emission on your application. Emissions are influenced by: Chamber conditions Fuel type Firing rate Ratio regulator adjustment Combustion air temperature Input () Fuel Orifice P (mbar) Fuel Orifice P ("w.c.) Fuel Orifice P vs. Input P measured between taps B and D (18.5 mm orifice) (1 mm orifice) (1 mm orifice) Air P (mbar) 1 9.0 Air P ("w.c.) 3.5 Air P vs. Air Flow (Measured between tap C and the chamber with the burner firing) Max. Air P firning into neutral chamber 3.5"w.c. (8.7 mbar) 0 250 500 750 0 1250 Input (x 0 BTU/hr) Input () 2500 5000 7500 00 12500 Air Flow (scfh) 70 140 210 280 350 Air Flow (Nm 3/ hr) 2 Eclipse Model RA0, v1 Data 115-1 10/1/07

Parameter Tube Specifications Maximum Input vs. Chamber Pressure () Model 60Hz, 4A (6"w.c. @ 16,500 scfh, 1/2 hp) 50Hz, 4A (6"w.c. @ 16,500 scfh,.37 ) "w.c. - - (mbar) -5,0-2,5 0,0 5,0 Specifications 60Hz Packaged 1,310,000 1,225,000 1,140,000 1,060,000 960,000 384 359 334 310 281 50Hz Packaged 1,320,000 1,245,000 1,165,000 1,086,000 985,000 387 365 341 316 288 NOx ppm 80 60 40 20 0 NOx Emission Data 0 250 500 750 0 1250 Input x (0 BTU/hr) NOx emission data is given for: Ambient combustion air ~70 F (20 C) Minimal process air velocity ppm volume dry at 3% O 2 Neutral chamber pressure CO emission is largely influenced by chamber conditions. Contact your local Eclipse Combustion representative for an estimate of CO emission on your application. Emissions are influenced by: Chamber conditions Fuel type Firing rate Ratio regulator adjustment Combustion air temperature Input () Fuel Orifice P (mbar) 1 9.0 3.5 Fuel Orifice P ("w.c.) Fuel Orifice P vs. Input P measured between taps B and D (18.5 mm orifice) (1 mm orifice) (1 mm orifice) Air P (mbar) 1 1 1 1 1 Air P ("w.c.) Air P vs. Air Flow (Measured between tap C and the chamber with the burner firing) Max. Air P firning into neutral chamber 6.5"w.c. (16.2 mbar) 0 250 500 750 Input (x 0 BTU/hr) 0 1250 4000 6000 8000 00 12000 14000 Air Flow (scfh) Input () 150 200 250 300 350 400 Air Flow (Nm 3/ hr) Eclipse Model RA0, v1 Data 115-1 10/1/07 3

Parameter Maximum Input vs. Chamber Pressure () Tube Specifications Model 60Hz, 4D (10"w.c. @ 22,00 scfh, 1 hp) 50Hz, 4D (10"w.c. @ 22,00 scfh,.75 ) "w.c. - - (mbar) -5,0-2,5 0,0 5,0 Specifications 60Hz Packaged 1,080,000 1,040,000 1,000,000 950,000 900,000 316 305 293 278 264 50Hz Packaged 1,052,000 1,010,000 964,000 917,000 867,000 308 296 282 269 254 NOx ppm 80 60 40 20 0 NOx Emission Data 0 250 500 750 0 1250 Input x (0 BTU/hr) NOx emission data is given for: Ambient combustion air ~70 F (20 C) Minimal process air velocity ppm volume dry at 3% O 2 Neutral chamber pressure CO emission is largely influenced by chamber conditions. Contact your local Eclipse Combustion representative for an estimate of CO emission on your application. Emissions are influenced by: Chamber conditions Fuel type Firing rate Ratio regulator adjustment Combustion air temperature Input () Fuel Orifice P vs. Input P measured between taps B and D (19.5 mm orifice) (1 mm orifice) (1 mm orifice) 3 3 2 Air P vs. Air Flow (Measured between tap C and the chamber with the burner firing) 1 Max. Air P firning into neutral chamber 11.2"w.c. (27.9 mbar) 1 Fuel Orifice P (mbar) Fuel Orifice P ("w.c.) Air P (mbar) 2 2 1 1 Air P ("w.c.) 1 0 250 500 750 0 1250 Input (x 0 BTU/hr) Input () 4000 6000 8000 00 12000 14000 Air Flow (scfh) 150 200 250 300 350 400 Air Flow (Nm 3/ hr) 4 Eclipse Model RA0, v1 Data 115-1 10/1/07

Dimensions mm (Inches) 775 (3) 226 (8.89) "A" "D" Filter/silencer option shown in gray. Tap "C" 1/2" N.P.T. Flame Rod or U.V. Scanner "B" Scroll Only 35 (1.4) See Page 4 For All Available Combustor Options 1" N.P.T. or B.S.P. Gas Inlet 1/2" N.P.T. or B.S.P. Pilot Option 439 (17.3) Tap "B" Tap "D" Gas Inlet C L 197 (7.75) "C" Scroll Only 102 () to Actuator Shaft C L 262 (10.3) For Honeywell Bracket 284 (11.2) for EMP Bracket "E" Filter Only 60Hz 50Hz Combustor Type Straight Straight Model 4H 4A 4D 4A 4D 4E 4A 4D Filter Type Rectangular Automotive Automotive Dimensions mm (inches) A B C D 301 (11.8) 346 (13.6) 430 (16.9) 519 (20.4) 519 (20.4) 519 (20.4) 670 (26.4) 359 (14.1) 448 (17.6) 507 (2) 448 (17.6) 507 (2) 448 (17.6) 507 (2) 587 (23.1) N/A 518 (20.4) 548 (21.6) 609 (2) 518 (20.4) 548 (21.6) 597 (23.5) E N/A 461 (18.1) 489 (19.2) 543 (21.4) 571 (2) 461 (18.1) 489 (19.2) 530 (20.9) Note: Standard round filters are illustrated above. Automotive filters are 508x508 (20x20). Rectangular filter is 256x256 (10x10). Burner Configuration & Piping Arrangement Inverted left hand piping Inverted right hand piping Upright left hand piping Upright right hand piping Eclipse Model RA0, v1 Data 115-1 10/1/07 5

Combustor Options Straight Alloy Tube (310 SST or Inconel) Medium & High Velocity Alloy Tube (310 SST) Mounting Pattern Ø 141 (5.5) Ø * Ø 141 (5.5) 330 (1) 230 (9.0) * 76 () 54 (2.1) 4 x Ø 12 (0.47) on 190 (7.5) B.C. Straight SiC Tube Medium & High Velocity SiC Tube Mounting Pattern Ø 148 (5.8) Ø * Ø 148 (5.8) 320 (12.6) 220 (8.7) * 76 () 54 (2.1) 4 x Ø 12 (0.47) on 190 (7.5) B.C. Block & Holder 50 () 305 (1) 267 (1) SQ. 222 (SQ. 8.7) 305 (1) 267 (1) 4 x Ø 14 219 (8.6) Data 115-1 10/1/07 Litho in U.S.A.