Data /1/07 Eclipse RatioAir Burners Model RA0040

Similar documents
RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

Eclipse RatioAir Burners

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

Eclipse RatioAir Burners


Eclipse Vortometric Burners Series HI

Capacities and Operating Data

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110

TriOx Triple Air Staged Ultra Low NOx Burner

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

North American 4485 Tempest SE

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

North American 4575 HiRAM

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction

Design and Application Details

LVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1

Eclipse Single-Ended Radiant Tube Burners

Low emissions, high performance natural gas burners

NOx-Beta Ultra Low NOx Burners

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Makotherm Thermal / Catalytic Oxidizer Operation and Maintenance Manual

KINEMAX. Medium velocity gas or oil burners

1200 SERIES FTR HOT AIR BAFFLE BURNER

MULTIFIRE. High temperature dual fuel burner

1470 SERIES HOT AIR GAS BURNER

1070 SERIES ULTRA LOW NO X

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm)

Design and Application Details

ECLIPSE TURBO BLOWERS SERIES SMJ

G96 Series BASOTROL Dual Operator Valve

Eclipse Butterfly Valves

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

2.0 Burner Operating Parameters and Requirements

1466 SERIES COLD AIR GAS/OIL BURNER

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

BBC Multi-fuel Combination Beta Burner

Specifications of STICKTITE and PILOTPAK Nozzles

Mark 695 Series. Pressure Regulators Mark 695 Piloted Tank Blanketing Regulators. Piloted Tank Blanketing Regulator 3/4"- 1" Optional Features

ECLIPSE TURBO BLOWERS SERIES SMJ

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

36H Gas Control Product Information

SGT-700 DLE combustion system extending the fuel flexibility

Design and Application Details

North American Combustion Burners

Mark 608BP Series. Pressure Regulators Mark 608BP Gas Pressure Regulators. Balanced Plug Gas Pressure Regulators. Features

PT-M90 Automatic Full-Sequence Modulation Gas Control System

Specifications of OPTIMA SLS Burners

OT LE 600/900/1200 GAS

Performance Selection Data

GEMINI GAS CONTROL PRODUCT INFORMATION

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB

Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry

Design and Application Details

LVDT/HC PILOT BURNER. External raw gas pilot burner

WET COMPRESSION. What it Is Not. What it Is. Is not traditional inlet air cooling, like a fogger or a chiller

VALUPAK. Packaged gas burners

North American Combustion Burners

BLOC U A-12G BLOC U C-12G

Economite RE Series. Power Gas Burners. MADE in the USA

Mark 908 Series. Pressure Regulators Mark 908X Piloted Blanketing Regulators

Specifications of STICKTITE and PILOTPAK Nozzles

1500 SERIES LARGE CAPACITY ULTRA 2 LOW NO X

LP BURNER SERIES.

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

all combustible gases and fuel oil, extra light gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼

VALUPAK. Packaged gas burners

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

Co Gen liner upgrade project Jan 2014 Huntsman 6 B conversion to Power System Manufacturing Low emissions combustion system

Sentronic D 608 Series and 609 Series

Mark 608 Series. Pressure Regulators Mark 608 Gas Pressure Regulators. Gas Pressure Regulators. Specifications. CRN Registration Number Available

P200 Pressure Regulator

Sentronic LP 617 Series

3/2-way Solenoid Valve for pneumatics

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

TECHNICAL SERVICE BULLETIN

APX Nozzle-mix line burner

P200 Pressure Regulator

DEXEN INDUSTRIES Inc. GENERAL CATALOG. DEXEN INDUSTRIES Inc.

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

F300 Pressure Regulator

P600 Pressure Regulator

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

Start-up Instructions

energy efficiency Zone valves

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

DOROT CONTROL VALVES CATALOGUE

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

36C and 36D Gas Control Product Information

P200 Pressure Regulator

PRESSURE REGULATOR. Lucifer EPP 4 - Basic. Description. Technical data

Transcription:

Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged Minimum input, () Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) Fuel pressure at ratio regulator inlet. High Fire Flame Length, inches (mm) Measured from the outlet end of the combustor. Maximum Flame Velocity, ft/s (m/s) Approximately 15% excess air at maximum input. Maximum chamber temperature, ºF (ºC) Alloy tube SiC tube Block & Holder Flame detection Fuel 445,000 (130) 420,000 (123) 420,000 (123) 462,000 (135) 429,000 (126) 429,000 (126) 400,000 (117) 4,000 (120) 400,000 (117) 4,000 (120) 419,000 (123) 409,000 (120) 390,000 (114) 370,000 (8) 390,000 (114) Not Available Not Available Not Available 30,000 (8.8) 30,000 (8.8) 30,000 (8.8) to 24 (25 to 60) to 24 (25 to 60) 15 to 24 (37 to 60) 24 (6) 18 (457) 14 (356) 1500 (816) 1900 (38) 1900 (38) 250 (75) 500 (150) 1750 (954) 2500 (1370) 2800 (1538) Data 115-5 /1/07 Eclipse RatioAir Burners Model RA0040 1750 (954) 2500 (1370) 2800 (1538) UV scanner available for all combustors. Flame rod available for alloy or SiC tubes, and (For any other gas, contact Eclipse Combustion for orifice sizing.) Version 1 Control and Operation Zone 00 % Excess Air 0 Typical Ratio Control Input and excess air at low fire changes with ratio regulator adjustment. 0 0 200 300 400 500 Input x 00 0 30 60 90 120 150 Input

Parameter Maximum Input vs. Chamber Pressure () Straight Tube Specifications Model 60Hz, 2G (6"w.c. @ 5,500 scfh, 1/3 hp) 50Hz, 2B (6"w.c. @ 5,500 scfh,.18 ) "w.c. - - (mbar) -5,0-2,5 0,0 2.5 5,0 Specifications 60Hz Packaged 530,000 490,000 445,000 396,000 340,000 155 144 130 116 0 50Hz Packaged 525,000 494,000 462,000 427,000 389,000 154 145 135 125 114 NOx ppm 90 80 70 60 50 40 30 20 NOx Emission Data 0 0 0 200 300 400 500 Input (x 00 BTU/hr) NOx emission data is given for: Ambient combustion air ~70 F (20 C) Minimal process air velocity ppm volume dry at 3% O2 Neutral chamber pressure CO emission is largely influenced by chamber conditions. Contact your local Eclipse Combustion representative for an estimate of CO emission on your application. Emissions are influenced by: Chamber conditions Fuel type Firing rate Ratio regulator adjustment Combustion air temperature Input () Fuel Orifice P (mbar) 1.0 Fuel Orifice P ("w.c.) Fuel Orifice P vs. Input P measured between taps B and D 1 (.6 mm orifice) (8.3 mm orifice) (7.6 mm orifice) Air P (mbar) 1 1 1 1.0 Air P ("w.c.) 7.0 Air P vs. Air Flow (Measured between tap C and the chamber with the burner firing) Max. Air P firning into neutral chamber 6.4"w.c. (15.9 mbar) 0 0 200 300 400 500 Input (x 00 BTU/hr) Input () 0 00 2000 3000 4000 5000 6000 Air Flow (scfh) 180 Air Flow (Nm 3/ hr) 2

Parameter Maximum Input vs. Chamber Pressure () Medium VelocityTube Specifications Model 60Hz, 2G (6"w.c. @ 5,500 scfh, 1/3 hp) 50Hz, 2B (6"w.c. @ 5,500 scfh,.18 ) "w.c. - - (mbar) -5,0-2,5 0,0 2.5 5,0 Specifications 60Hz Packaged 457,000 430,000 400,000 368,000 334,000 134 126 117 8 98 50Hz Packaged 466,000 440,000 4,000 380,000 346,000 136 129 120 111 1 NOx ppm 70 60 50 40 30 NOx Emission Data 20 0 0 0 200 300 400 500 Input (x 00 BTU/hr) NOx emission data is given for: Ambient combustion air ~70 F (20 C) Minimal process air velocity ppm volume dry at 3% O2 Neutral chamber pressure CO emission is largely influenced by chamber conditions. Contact your local Eclipse Combustion representative for an estimate of CO emission on your application. Emissions are influenced by: Chamber conditions Fuel type Firing rate Ratio regulator adjustment Combustion air temperature Input () Fuel Orifice P (mbar) 1.0 Fuel Orifice P ("w.c.) Fuel Orifice P vs. Input P measured between taps B and D 1 (.8 mm orifice) (8.4 mm orifice) (7.9 mm orifice) Air P (mbar) 1 1 1 1.0 Air P ("w.c.) 7.0 Air P vs. Air Flow (Measured between tap C and the chamber with the burner firing) Max. Air P firning into neutral chamber 6.6"w.c. (16.4 mbar) 0 0 200 300 400 500 Input (x 00 BTU/hr) Input () 0 00 2000 3000 4000 5000 6000 Air Flow (scfh) 180 Air Flow (Nm 3/ hr) 3

High VelocityTube Specifications Model 2C ("w.c. @ 5,500 scfh, 1/3 hp) Specifications Parameter Frequency "w.c. 440,000-129 (mbar) -5,0 Maximum Input vs. Chamber Pressure () 60Hz Packaged 420,000 400,000 380,000-123 117 111-2,5 0,0 2.5 360,000 5 5,0 NOx ppm 70 60 50 40 30 NOx Emission Data 20 0 0 0 200 300 400 500 Input (x 00 BTU/hr) NOx emission data is given for: Ambient combustion air ~70 F (20 C) Minimal process air velocity ppm volume dry at 3% O2 Neutral chamber pressure CO emission is largely influenced by chamber conditions. Contact your local Eclipse Combustion representative for an estimate of CO emission on your application. Emissions are influenced by: Chamber conditions Fuel type Firing rate Ratio regulator adjustment Combustion air temperature Input () Fuel Orifice P (mbar) 1 1.0 Fuel Orifice P ("w.c.) Fuel Orifice P vs. Input P measured between taps B and D (1 mm orifice) (8.8 mm orifice) (8.2 mm orifice) Air P (mbar) 3 2 2 1.0 Air P ("w.c.) 1.0 Air P vs. Air Flow (Measured between tap C and the chamber with the burner firing) Max. Air P firning into neutral chamber 9.7"w.c. (24.2 mbar) 0 0 200 300 400 500 Input (x 00 BTU/hr) Input () 0 00 2000 3000 4000 5000 6000 Air Flow (scfh) 180 Air Flow (Nm 3/ hr) 4

662 (24.5) 217 (8.5) 287 (11.3) "C" Filter/silencer option shown in gray. "A" Scroll Only 35 (1.4) 1/2" N.P.T. Flame Rod or U.V. Scanner See Page 4 For All Available Combustor Options 3/4" N.P.T. or B.S.P. Gas Inlet 1/2" N.P.T. or B.S.P. Pilot Option 418 (16.5) Gas Inlet C L 167 (6.6) "B" Scroll Only 85 (3.4) to Actuator Shaft C L 251 (9.9) For Honeywell Bracket 269 (.6) for EMP Bracket "D" Filter Only Straight & Medium Velocity High Velocity 2G 2C Round Round 412 (16.2) 503 (19.8) 394 (15.5) 475 (18.7) 442 (17.4) 489 (19.3) 432 (17.0) 469 (18.5) Straight & Medium Velocity 2B Round 503 (19.8) 475 (18.7) 489 (19.3) 469 (18.5) * When using Honeywell or Siemens actuators with right hand piping, add 35mm (1.4") Inverted left hand piping Inverted right hand piping Upright left hand piping Upright right hand piping 5

Combustor Options Straight Alloy Tube (3 SST) Medium & High Velocity Alloy Tube (3 SST) Mounting Pattern Ø 88.9 (3.5) Ø * Ø 88.9 (3.5) 240 (9.4) HV = 213 (8.4) MV = 194 (7.6) * Medium Velocity 60 (2.4) High Velocity 42 (17) 4 x Ø 12 (0.47) on 136 (5.4) B.C. Straight SiC Tube Medium & High Velocity SiC Tube Mounting Pattern Ø 94 (3.7) Ø * Ø 95 (3.7) 230 (9.1) 230 (9.0) * Medium Velocity 60 (2.4) High Velocity 42 (1.7) 4 x Ø 12 (0.47) on 136 (5.4) B.C. Block & Holder Ø 218 O.D. Ø (8.6) O.D. 50 () 135 (5.3) Ø 147 Ø (5.8) 135 (5.3) 4 x Ø 12 230 (9.1)

Offered By: Burnerparts.com 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3881 Fax (804) 236-3882 www.burnerparts.com