Feasibility of Ultra Long-Span Suspension Bridges Made of All Plastics

Similar documents
AERODYNAMIC STABILITY OF A SUPER LONG-SPAN BRIDGE WITH SLOTTED BOX GIRDER

Composite Long Shaft Coupling Design for Cooling Towers

Parametric study on behaviour of box girder bridges using CSi Bridge

Plate Girder and Stiffener

Aerodynamic Investigation of Cable-stayed Bridge with 2-edge Girder

Static Instability Analysis of Long-Span Cable-Stayed Bridges with Carbon Fiber Composite Cable under Wind Load

Transverse Distribution Calculation and Analysis of Strengthened Yingjing Bridge

Oscillator Experiment of Simple Girder Bridge coupled with Vehicle

The effectiveness of CFRP strengthening of steel plate girders with web opening subjected to shear

Current collecting characteristics of catenary with non-tension contact wires

Seismic-upgrading of Existing Stacks of Nuclear Power Station using Structural Control Oil Dampers

COST ANALYSIS FOR BRIDGE AND CULVERT. Essam A. Mostafa

CHAPTER 1 BALANCING BALANCING OF ROTATING MASSES

Special edition paper

Conceptual Design of Hybrid Cable-Stayed Bridge with Central Span of 1000 m Using UHPC

Design principles and Assumptions

NUMERICAL ANALYSIS OF LOAD DISTRIBUTION IN RAILWAY TRACK UNDER WHEELSET

TITLE: EVALUATING SHEAR FORCES ALONG HIGHWAY BRIDGES DUE TO TRUCKS, USING INFLUENCE LINES

Analysis of Torsional Vibration in Elliptical Gears

THE LONGITUDINAL VIBRATION OF COMPOSITE DRIVE SHAFT

2. Write the expression for estimation of the natural frequency of free torsional vibration of a shaft. (N/D 15)

KEYWORDS: ANSYS, Clamping effects, Leaf spring, Pro-E. International Journal of Computational Engineering Research Vol, 03 Issue, 10

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine

A LES/RANS HYBRID SIMULATION OF CANOPY FLOWS

Design and Test of Transonic Compressor Rotor with Tandem Cascade

Dynamic characteristics of railway concrete sleepers using impact excitation techniques and model analysis

Analysis Methods for Skewed Structures. Analysis Types: Line girder model Crossframe Effects Ignored

Dynamic Response of High-Speed-Moving Vehicle Subjected to Seismic Excitation Considering Passengers' Dynamics

EXPERIMENTAL STUDY ON EFFECTIVENESS OF SHEAR STRENGTHENING OF RC BEAMS WITH CFRP SHEETS

BRE/TSLAB Vulcan Comparisons. Roger Plank Anthony Abu & Ian Burgess

EFFECT OF SURFACE ROUGHNESS ON PERFORMANCE OF WIND TURBINE

Clamping Force Effects on the Behaviour of Asymmetrical Friction Connections (AFC)

Study on Electromagnetic Levitation System for Ultrathin Flexible Steel Plate Using Magnetic Field from Horizontal Direction

Comparative Study on Super Structure of Box Girder Bridge and Cable Stayedbridge with Extra Dosed Bridge

PARAMETRIC STUDY OF CABLE STAYED BRIDGE

DESIGN AND ANALYSIS OF LEAF SPRING FOR SOLAR VEHICLE

CONSULTING Engineering Calculation Sheet. Reference Sheets - Pile Cap Capacity (Generic) Tables XX

Application of ABAQUS to Analyzing Shrink Fitting Process of Semi Built-up Type Marine Engine Crankshaft

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

DESIGN AND FABRICATION OF CHASSIS FOR ELECTRICAL VEHICLE

Effects of Container Size, Stroke and Frequency on Damping Properties of a Damper Using a Steel Particle Assemblage

Experimental Investigation of Effects of Shock Absorber Mounting Angle on Damping Characterstics

HYSTERISIS CHARACTERISTIC OF LEAD PILLAR DAMPER

Development of Rattle Noise Analysis Technology for Column Type Electric Power Steering Systems

Damping Ratio Estimation of an Existing 8-story Building Considering Soil-Structure Interaction Using Strong Motion Observation Data.

Comparison of T-Beam Girder Bridge with Box Girder Bridge for Different Span Conditions.

A study on the vibration analysis of a maglev vehicle A theoretical investigation of the effect of magnetic damping on a vibration control system

3D NONLINEAR AEROSTATIC STABILITY ANALYSIS FOR SUSPENSION BRIDGES WITH ULTRA-LONG SPAN

ANALYSIS OF MONO LEAF SPRING

Vehicle Turn Simulation Using FE Tire model

LEVER OPTIMIZATION FOR TORQUE STANDARD MACHINES

STRUCTURAL DESIGN AND ANALYSIS OF ELLIPTIC CYCLOCOPTER ROTOR BLADES

Development of Feedforward Anti-Sway Control for Highly efficient and Safety Crane Operation

Seismic Capacity Test of Overhead Crane under Horizontal and Vertical Excitation - Element Model Test Results on Nonlinear Response Behavior-

Design and Vibrational Analysis of Flexible Coupling (Pin-type)

RESILIENT INFRASTRUCTURE June 1 4, 2016

Case Study of Bridge Load Rating in KY using BrR. C.Y. Yong, P.E., S.E., ENV-SP

VEHICLE ANTI-ROLL BAR ANALYZED USING FEA TOOL ANSYS

Finite Element Modeling and Analysis of Vehicle Space Frame with Experimental Validation

4.5 COMPOSITE STEEL AND CONCRETE

Reduction of Oil Discharge for Rolling Piston Compressor Using CO2 Refrigerant

EXPERIMENTAL AND NUMERICAL STUDIES OF THE SCISSORS-AVLB TYPE BRIDGE

Influence of cross beam spacing on load distribution factor at girder bridges

OPTIMUM DESIGN OF OVERHEAD CRANE GIRDERS UNDER MOVING LOADS

Dynamic Behavior Analysis of Hydraulic Power Steering Systems

Chapter 2 Dynamic Analysis of a Heavy Vehicle Using Lumped Parameter Model

[Pancholi* et al., 5(6): June, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

The FRACOF Composite Slab Test

Suppression of chatter vibration of boring tools using impact dampers

Munich Fire Tests on Membrane Action

Optimization of Scissor-jack-Damper s Parameters and Performance under the Constrain of Human Comfort

EXPERIMENTAL INVESTIGATION OF THE FLOWFIELD OF DUCT FLOW WITH AN INCLINED JET INJECTION DIFFERENCE BETWEEN FLOWFIELDS WITH AND WITHOUT A GUIDE VANE

Research on Skid Control of Small Electric Vehicle (Effect of Velocity Prediction by Observer System)

A Fundamental Study Concerning the Proper Performance of Lift Buffers in Revised JIS A 4306

UT Lift 1.2. Users Guide. Developed at: The University of Texas at Austin. Funded by the Texas Department of Transportation Project (0-5574)

Hours / 100 Marks Seat No.

Discussion of Marine Stirling Engine Systems

Research on Test Methods of Frame Torsional Rigidity Lu JIA1,2, Huanyun DAI1 and Ye SONG1

Chapter 2 Analysis on Lock Problem in Frontal Collision for Mini Vehicle

DESIGN OF A MODIFIED LEAF SPRING WITH AN INTEGRATED DAMPING SYSTEM FOR ADDED COMFORT AND LONGER LIFE

MECHANICAL EQUIPMENT. Engineering. Theory & Practice. Vibration & Rubber Engineering Solutions

Guide Vanes for Darrieus Water Turbine in Tidal Current

Finite Element Analysis of Clutch Piston Seal

Gantry Girders in India

Optimization of Seat Displacement and Settling Time of Quarter Car Model Vehicle Dynamic System Subjected to Speed Bump

SOLUTIONS FOR SAFE HOT COIL EVACUATION AND COIL HANDLING IN CASE OF THICK AND HIGH STRENGTH STEEL

RELIABILITY IMPROVEMENT OF ACCESSORY GEARBOX BEVEL DRIVES Kozharinov Egor* *CIAM

DESIGN OF FRONT END ACCESSORIES FOR A TWO CYLINDER ENGINE

Analysis and measurement of damping characteristics of linear generator

Simulating Rotary Draw Bending and Tube Hydroforming

JSSI MANUAL FOR BUILDING PASSIVE CONTROL TECHNOLOGY PART-10 TIME-HISTORY ANALYSIS MODEL FOR NONLINEAR OIL DAMPERS

On the potential application of a numerical optimization of fatigue life with DoE and FEM

Reducing the Structural Mass of a Real- World Double Girder Overhead Crane

Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor

FINITE ELEMENT SIMULATION OF SHOT PEENING AND STRESS PEEN FORMING

Development of Assist Steering Bogie System for Reducing the Lateral Force

Optimization of Design Based on Tip Radius and Tooth Width to Minimize the Stresses on the Spur Gear with FE Analysis.

A Study of an Earthworm type Inspection Robot Movable in Long Pipes

Evaluation of the Fatigue Life of Aluminum Bogie Structures for the Urban Maglev

Simulation and Analysis of Vehicle Suspension System for Different Road Profile

Transcription:

IASE SYMPOSIUM MELOURNE 1 Feasibility of Ultra Long-Span Suspension ridges Made of All Plastics Ken-ichi MAEDA Professor Dr. Eng. Tokyo Metropolitan Univ. Tokyo, Japan Torahiko IKEDA ridge Engineer M. Eng. Chodai Co., Ltd. Ibaraki, Japan Hitoshi NAKAMURA Research Associate M. Eng. Tokyo Metropolitan Univ. Tokyo, Japan Seishi MEIARASHI Team Leader Ph. D. Public Works Research Institute Ibaraki, Japan Summary In this study, we examined the feasibility of ultra long-span suspension bridges made using fiberreinforced plastic. After we confirmed the necessity of making in plastics all, a 3-span -hinged suspension bridge with the center span of 5,m and the sag ratio of 1/ was trially designed, and the static structural characteristics were elucidated. Moreover, by applying coupled flutter analysis, various countermeasures for ensuring high aerodynamic stability were investigated, and the feasibility was discussed considering all results. Keywords: ultra long-span bridge; suspension bridge; tubular stiffening girder; fiber-reinforced plastic; CFRP; GFRP; structural characteristics; aerodynamic stability 1. Introduction The progress of the development of fiber-reinforced plastics (FRPs) has been considerable in recent years, and they are spotlighted as new materials for civil engineering structures [1]. In particular, by using carbon-fiber-reinforced plastic (CFRP) cables in the main cable of a suspension bridge instead of steel cables, it has been indicated that dead loads can be drastically reduced, as the center span becomes longer and longer, because of the ultralight weight of such cables. []. Furthermore, for bridges with the span of 5,m, it is easily confirmed [3] that CFRP must also be used in the stiffening girder as well as the main cable, even if new types (for example, the Dischinger type [4]) are applied, when the sag ratio becomes lower due to constraint of the tower height. However, such lightening may lower the aerodynamic stability, which would greatly influence the feasibility, and it is also expected that adequate countermeasures for ensuring higher stability will become necessary. From the above-mentioned viewpoint, we examined the feasibility of ultra long-span suspension bridges made using fiber-reinforced plastics all. First, after we confirmed the necessity of making in plastics all, a 3-span -hinged suspension bridge with the center span of 5,m was trially designed as follows. CFRP cables were used in the main cable with the sag ratio of 1/, and CFRP and concrete composite columns were adopted for the tower. In the stiffening girder, vehicles were assumed to run the inside through a tubular beam [5] made of CFRP. CFRP was also used in the deck slab, but in the floor system, glass-fiber-reinforced plastic (GFRP) was used. Next, on the basis of this trial design, analytical modeling was conducted by varying sectional values and boundary conditions of the stiffening girder, and the static structural characteristics were examined under various design loads. Moreover, the aerodynamic stability was investigated by applying the coupled flutter analysis [6], and the effects of various countermeasures on the improvement of stability were verified in order to sufficiently ensure it. Finally, from all results, the feasibility of all-plastic suspension bridges of the 5,m-span class was discussed, including problems remaining for the future.

IASE SYMPOSIUM MELOURNE. Necessity of Making in All Plastics To ensure higher feasibility of suspension bridges of the 5,m-span class, the tower height must be restrained to about 3m by decreasing the sag ratio to about 1/. Currently, the predominant ratio is 1/1 and the tower height far exceeds 5m, making the feasibility low. For the center span of a suspension bridge, by assuming the shape of the main cable to be a parabola, the maximum tension T and its relationship with the allowable stress σ a are obtained as ( w T = + ws ) λ f ( wc + ws ) λ c 1+ 16 = 1 + 8 f λ T A σ a (), where λ, n (=f / λ), A, w c and w s are the span length, the sag ratio, the sectional area, the own weight of the main cable and the sum total of dead and live loads of the stiffening girder, respectively. Eq. () becomes the following equation because w c =γ c A, when the unit weight of the main cable is set as γ c : 8n 16n (1), λ ( w c 8nσ A + w ) s a 1+ 16n 8nσ a = γ (1 + w w ) c s c 1+ 16n (3). Therefore, considering n and w s /w c to be parameters, curves of the critical span length λ cr are plotted in Fig.1 and Fig., where values of γ c and σ a are taken from Table 1 for steel cables and CFRP cables. From these figures, it is easily confirmed that CFRP must also be used in the stiffening girder as well as in the main cable, in order to restrain the tower height to about 3m for bridges with span of 5,m. This is because, with the sag ratio of 1/, the self-support becomes all, when steel Table 1 Unit Weight and Allowable Stress Steel CFRP γ c ; Unit Weight [N/m 3 ] 77.7 σ t ; Tensile Strength [N/mm ] 6 45 ν; Safety Factor..5 σ a ; Allowable Stress [N/mm ] 98 98 Critical span length l cr (m) 1 1 8 6 5 4 Unit weight: γ c =77 kn/m 3 Allowable stress: σ a = 98 N/mm f=l /8 f=l /1 f=l / f= l /1 1.. 3. 4. 5. 6. 7. w s /w c Fig.1 Critical Span Length (Steel cables) Critical span length l cr (m) 1 1 8 6 5 4 f=l / f= l /8 f=l /1 f=l /1 Unit weight: γ c =.7 kn/m 3 Allowable stress: σ a = 98 N/mm 1.. 3. 4. 5. 6. 7. w s /w c Fig. Critical Span Length (CFRP cables)

IASE SYMPOSIUM MELOURNE 3 cables are used, and further reduction of dead loads is required, even when CFRP cables are used. 3. Trial Design and Material Property In this study, a 3-span -hinged suspension bridge with the center span of 5,m and the sag ratio of 1/, shown in Fig.3, was trially designed and as an object of the examination. 198 5 198 4.6 8 374.5 Unit: m Fig.3 Trial Design CFRP cables were used in the main cable, and CFRP and concrete composite columns were adopted for the tower. The tower was designed as steel-reinforced concrete columns, but the amount of steel reinforcement was replaced with the CFRP plate thickness. As shown in Fig.4, a tubular beam made of CFRP was used as the stiffening girder in order to decrease design wind loads, and to ensure torsional rigidity. Four lanes of traffic were assumed to pass through the tube. CFRP was also used in the deck slab. In contrast, in the floor system, which is not a structural member, GFRP was used because of its low cost. Table shows the properties of structural materials used in the main cable, the stiffening girder and the tower. CFRPs used in the stiffening girder and the tower were the same, and their cross sections were assumed to be composed of connecting pulltruded profiles. However, two values of the safety factor ν, 6. and 7.5, of the CFRP used in the stiffening girder were adopted, because the appropriate value has not yet been clearly determined. y carrying out a rough design under the various design loads listed Table 3, the sectional area of the main cable was found to be about.8m. The cross section of the stiffening girder, shown in Fig.5, was decided based on the stress due to the bending moment under design wind loads, and so as to increase the plate thickness in a narrow range, when the value of the safety factor ν was 7.5. Fig.6 shows the cross section of the tower. 14.5 117.5 Fig.4 Schematic View Table Material Properties Main Cable Stiffening Girder Kind of Material CFRP CFRP Unit Weight [N/m 3 ].7.7 Elastic Coefficient [GPa] Elastic Shear Coefficient [GPa] Thermal Expansion Coefficient [1/Deg.] Tensile (Compressive) Strength [N/mm ] 16 64-9 Tower CFRP/ Concrete.7/ 3. 64/ 3 9/ 13.1x1 6.1x1 6-45 1 Safety Factor; ν. 6. 7.5 Allowable Stress [N/mm ] 98 17 136 1/ 6 6./ 3.3 17/ 18

IASE SYMPOSIUM MELOURNE 4 Consequently, there is no problem from the viewpoint of construction, including the structures of bands and saddles in which each strand is stored separately, because the sectional area of the main cable is sufficiently smaller than 1.m. Also, excess of allowable stress can be easily coped by making the stiffening girder locally nonuniform when the safety factor is required to be higher. Live Load Wind Load Table 3 Design Loads Main Cable Stiffening Girder Center Span Side Span Center Span Side Span Dead Load (Uniform Section) 6.74 7.18 8.47 8.5 Concentrated Load [kn/m/r.] - - 17.54 Distributed Load [kn/m/r.] - -. Design asic Wind Speed: U 1 [m/sec] 46 Standard Height: Z [m] 36.63 98.75 Drag Force Coefficient: C D.7 1. Wind Load [kn/m/r.] 4.9 48.83 Incremental Coefficient of Allowable Stress - 1.5 4 36 C C 5 1 1 1 1 - Uniform Section (ν=6.) 1 A - A 1 5 1 47 D D 35 35 35 35 3 A A 45 5 - Increased Thickness Range ( Section (ν=7.5)) 3 1 1 1 3 E 1 1 8 3 1 1 1 8 Unit: mm C L E - E 1 E 3 D - D 1 3 C - C 1 Fig.5 Cross Section of Stiffening Girder Uniform Section Increased Thickness Range ( Section) 36 7 6 5 1 - A Concrete CFRP 1 6 755 8 3745 1 555 145 5 Fig.6 Cross Section of Tower Part A in detail Perfobonded Rib Dowel 1 1 - Unit: mm

IASE SYMPOSIUM MELOURNE 5 4. Static Structural Characteristics To examine the static structural characteristics, a finite displacement analysis was carried out using 3-D frame models, as shown in Fig.7, in which the stiffening girder was regarded as a fish-bone model. Table 4 shows the sectional values of each member derived from the result of trial design. As shown in this table, two cases of the cross section of the stiffening girder were made uniform and nonuniform sections. Furthermore, the case in which the stiffening girder was assumed to be continuous was also examined for reference. The analytical results are shown in Fig.8 to Fig.13. As the primary feature from these figures, it is Table 4 Sectional Values Stiffening Girder Uniform Nonunif. Main Cable Hanger Tower E (GPa) 64 64 16 16 3 A (m ) 3.7 3.7, 4.91.794.6 I in (m 4 ) 53.7 53.7, - - 8.73 I out (m 4 ) 53.89 53.89, - - 714.35 65.64-99.14 517.3-3. 869.5-6469. G (GPa) 9 9 - - 13 J (m 4 ) 176.5 176.5, 65.86 - - 118. - 37. 8 Increased Thickness Range ( Section) Fish-one Model Fig.7 Analytical Model Tension (kn) 75 7 65 6 Under (D+L) Load Under D Load ending moment (kn m) 16 1 8 4 55 4 Fig.8 Tension of Main Cable Fig.9 ending Moment of Stiffening Girder under Dead & Live Loads under Thermal Change of +3Deg. Displacement (m) 1 5 5 1 Ratio: 1/35 Ratio: 1/5 ending moment (kn m) 6 5 4 3 1 5 Fig.1 Deflection of Stiffening Girder under Live Loads 1 Fig.11 ending Moment of Stiffening Girder under Live Loads

IASE SYMPOSIUM MELOURNE 6 Displacement (m) 4 6 8 1 1 Ratio: 1/5 Ratio: 1/4 ending moment (x1 3 kn m) 1 5 5 14 Fig.1 Deflection of Stiffening Girder under Wind Loads 1 Fig.13 ending Moment of Stiffening Girder under Wind Loads found that displacements due to deflection are large both in-plane and out of plane, but they are not quantities which become the problems due to the vehicle travel and structural reliability. Moreover, it is also proved that the effect in which their displacements are reduced is negligible; only the negative bending moment at the intermediate support rapidly increases even if the stiffening girder is designed to be continuous. 5. Aerodynamic Stability against Coupled Flutter To investigate the aerodynamic stability, the coupled flutter analysis of the three models described below was carried out on the basis of the modal analysis, by applying the unsteady force based on the plate-wing theory, and by considering the natural vibration mode up to the 4th mode. The three models are based on a uniform section described in Chapter 4 (the basic model) and two models in which the structural countermeasures shown in Fig.14 and Fig. were adopted (the ST-1 model and the ST- model). Namely, in the ST-1 model, the cross hangers were concentrated at optimum positions, and in the ST- model, the cross hangers and the horizontal cross-stays were positioned throughout length of the bridge. Table 5 and Fig.16 respectively show the critical wind velocity Ucr, the natural frequency of the basic modes and the U-δ curves of the three models with structural damping of logarithmic decrement.. The table and figure indicate that the aerodynamic stability against coupled flutter decreases markedly, but by adopting the structural countermeasures, the critical wind velocity can be ensured to the value of about 6m/sec. Table 5 Analytical Results Fig.14 Cross Hanger Fig. Horizontal Cross-Stay asic Model ST-1 Model ST- Model Critical Wind Velocity: Ucr [m/sec] 37.7 53.3 59.1 Natural 1st Symm. Deflection Mode [Hz].511.51.51 Frequency 1st Symm. Torsion Mode [Hz].1784.18.1954 Fig.17 shows the critical wind velocity Ucr of the three models where only the torsional rigidity was changed. It indicates that the aerodynamic stability is not sufficiently improved, by increasing only the torsional rigidity of the stiffening girder due to the variation of the shape of the cross

IASE SYMPOSIUM MELOURNE 7 section or the elastic shear coefficient of.5 CFRP. Fig.18 shows the critical wind velocity Ucr of. the three models in the case of redesign by changing the plate thickness of the stiffening. girder, and Fig.19 shows the U-δ curve of the ST- model in the case where only structural damping was changed..1 These figures indicate that if the plate.5 thickness of the stiffening girder is about or 3 times the value decided from the static design, the critical wind velocity can be. ensured to the value of about 7m/sec or 8m/sec. In contrast, it is also proved that the -.5 critical wind velocity can be ensured to about 7m/sec without greatly reducing the Fig.16 U-δ curve economical efficiency when structural damping is sufficiently increased by installing an adequate damper system. 6. Conclusions Logarithmic decrement asic model ST-1 model ST- model Wind velocity U (m/sec) 1 3 4 5 6 7 8 As a result of this study, we found the following concerning the feasibility of all-plastic suspension bridges of the 5,m-span class. Critical wind velocity Ucr (m/sec) 9 8 7 6 5 4 3 59.1 6. 53.3 54.1 37.7 4. Fig.17 Effect due to Change of Torsional Rigidity asic model ST-1 model ST- model 1. 1.5. Times of rigidity 58.8 56. 5.7 Critical wind velocity Ucr (m/sec) 9 8 7 6 5 4 3 asic model ST-1 model ST- model 59.1 53.3 37.7 7. 64.7 49.7 1.. 3. Times of thickness Fig.18 Effect due to Change of Plate Thickness of Stiffening Girder 8.4 74. 59.4 Logarithmic decrement δ.3.5...1.5. -.5 ST- model Structural Damping (Logarithmic decrement)..4.6.8.1 Wind velocity U(m/s) 1 3 4 5 6 7 8 Fig.19 Effect due to Change of Structural Damping

IASE SYMPOSIUM MELOURNE 8 (1) y using CFRP for the stiffening girder as well as for the main cable, a feasible design becomes possible even with the sag ratio of 1/. As a result, the tower height can be restrained to about 3m, and the tower can be designed as CFRP and concrete composite columns. With the currently predominant ratio of 1/1, the tower height far exceeds 5m, making the feasibility low. () The cross section of the stiffening girder is determined based on the stress due to the bending moment under design wind loads, and excess of allowable stress can be easily coped by making the stiffening girder locally nonuniform when the safety factor of material is required to be higher. There is no problem from the viewpoint of construction, including the structures of bands and saddles in which each strand is stored separately, because the sectional area of the main cable is sufficiently smaller than 1.m. (3) Although the primary feature of the static structural characteristics is that displacements due to deflection are large both in-plane and out of plane, they are not the quantities which become the problems due to the vehicle travel and structural reliability. Even if the stiffening girder is designed to be continuous, only the negative bending moment at the intermediate support rapidly increases, and the effect in which their displacements are reduced is negligible. (4) The aerodynamic stability against coupled flutter decreases markedly, but by adopting structural countermeasures (for example, the cross hanger, the horizontal cross-stay, etc.), the critical wind velocity can be ensured to the value of about 6m/sec. However, increasing the torsional rigidity of the stiffening girder merely by varying the shape of the cross section or the elastic shear coefficient of material does not appreciably improve the aerodynamic stability. (5) In order to ensure the critical wind velocity to the value of about 7m/sec or 8m/sec, it may be necessary to make the plate thickness of the stiffening girder about or 3 times the value decided from the static design, respectively. In contrast, when structural damping is sufficiently increased by installing an adequate damper system, the critical wind velocity can be ensured to about 7m/sec without greatly reducing the economical efficiency. Therefore, although problems concerning, for example, the structure of hinge parts and the connection of pulltruded profiles, remain for future studies, the present results indicate that the feasibility of constructing all-plastic suspension bridges is not low. References [1] IASE Publications Committee (WG3 New Materials), Advanced Materials, Structural Engineering International, Journal of IASE, Vol.9, No.4, 1999. [] K. Maeda, Y. Morizono, H. Nakamura, T. Eguchi and Y. Fujino, Applicability of CFRP Cables to Ultra Long-Span Suspension ridges, Proc. of IASE Conference in Seoul on Cable-Supported ridges Challenging Technical Limits, CD-ROM (IASE Report, Vol.84), 1. [3] T. Kawada, et al., The modern suspension bridge, Rikohtosho, 1987. (in Japanese and in Korean) [4] N. Narita, K. Maeda, H. Nakamura, and K. Nomura, Applicability of Dischinger-Type to Ultra-Long Span ridges, Proc. of IASE Symposium in Kobe on Long-Span and High-Rise Structures, IASE Report, Vol.79, pp.137-14, 1998. [5] K. H. Ostenfeld (COWI Consult), ridges of Today and Tomorrow, 1th Annual International ridge Conference, Pittsburgh, Pennsylvania, June 1993. [6] M. Iwamoto, Prediction of Aerodynamic ehavior of Cable Supported ridges, Ph. D. thesis, University of Tokyo, 1995. (in Japanese)