IECEx Certificate of Conformity

Similar documents
IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Endress+Hauser Wetzer GmbH+Co. KG Obere Wank Nesselwang Germany. Field Temperature Transmitter itemp, Types TMT82, TMT84 and TMT85

IECEx Certificate of Conformity

TB range of empty sheet metal enclosures. R S Sindair K~'

TECHNICAL BULLETIN. Sandvik MB670 Bolter Miners

IECEx Certificate of Conformity

The ISF003 is a range of overmoulded 0603 or smaller surface mounted fuses nominally sized 5.6 mm (L) x

Certificate of Conformity

The filling level sensors are designed in accordance to the following standards

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

COMMISSION REGULATION (EC)

DLA Land and Maritime - VQ Supplemental Information Sheet for Electronic QPL-23419

"LITTELFUSE" non-renewable cartridge fuses, supplemental type, as follows:

COVER PAGE FOR TEST REPORT

Certificate of Compliance

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Certificate of Conformity

Attachment to Certificate IECEx PTB X

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

Solenoid Operator 0516 / 1216

CERTIFICATE OF COMPLIANCE

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

OPERATING INSTRUCTIONS

Magnetic Switches for WEKA Visual Level Indicators Australian Version

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Operating Instructions in accordance with IECEx Scheme rules, IECEx 02 polykom


Solenoid coil for control in potentially explosive areas Type BZ

NCC Leisure Battery Verification Scheme. Leisure Accommodation Vehicles

NPS/001/017 Technical Specification for Low Voltage and High Voltage Current Limiting Fuse Links

Guideline No.: E-03(201806) E-03 MOTORS. Issued date: June 7, China Classification Society

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Certificate of Conformity

A good connection. International approvals.

IECEx Cert f cate. of Conformity. lru

UN ECE Sectoral Initiative on Equipment for Explosive Atmospheres. United States Department of Labor Mine Safety and Health Administration (MSHA)

12468/10 SJC/fp 1 DG I 1A

UL TEST REPORT AND PROCEDURE

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Instruction Manual. Ex-Time 40 / 50

Measuring insert for resistance thermometer Model TR10-A

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

Measuring insert for process resistance thermometer

Low voltage motors for hazardous areas Safe, reliable and highly efficient

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Tillers Motor hoes (combustion engine powered)

ATEX LABELLING FOR MOTORS AND GEAR UNITS

Direct-acting 3/2 way plunger valve

International approvals.

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

COMMISSION REGULATION (EU)

2/2 Solenoid Cartridge Valve, Size 6

ISO INTERNATIONAL STANDARD. Road vehicles Test methods for electrical disturbances from electrostatic discharge

A good connection. International approvals.

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

E/ECE/324/Add.5/Rev.6/Amend.2 E/ECE/TRANS/505/Add.5/Rev.6/Amend.2

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Based on NFPA 1002: Standard for Fire Apparatus Driver/Operator Professional Qualifications, 2009 Edition.

ISO INTERNATIONAL STANDARD. Gas turbines Procurement Part 3: Design requirements

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

ISO INTERNATIONAL STANDARD

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

This document is a preview generated by EVS

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

ILED Dorado. User Manual

INTERNATIONAL STANDARD

UL TEST REPORT AND PROCEDURE

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

Chain-saws (combustion engine powered)

EU-Mexico Free Trade Agreement EU TEXTUAL PROPOSAL

Leading the way in hazardous areas Features EATON

E/ECE/324/Rev.2/Add.104/Rev.2/Amend.3 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2/Amend.3

Certificate of Conformity

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

ANNEX MOTOR VEHICLES AND EQUIPMENT AND PARTS THEREOF. Article 1. Definitions

Operating Instructions

for the use of SIQ Type Approved certification mark Sl-SIQ BG 004/081 Project file: C DIN Rail Power Supply

This document is a preview generated by EVS

EX-REPAIR AND MAINTENANCE RECEPTACLES

This document is a preview generated by EVS

Certificate of Compliance

IECEx Certificate of Conformity

for the use of SIQ Type Approved certification mark 51-SIQ BG 004/130 Project file: C DIN Rail Power Supply

Ex m Solenoid Operator Type 0519

ENEC LICENCE. Licence No. ENEC M1 Page 1/5 Date of Issue

11 Control Panels, Distribution Panels and Components

ISO INTERNATIONAL STANDARD. Bi-directional and multi-directional fork-lift trucks Stability tests

Ride-on lawnmowers (combustion engine powered)

Transcription:

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 13.0077U issue No.:1 Status: Current Date of Issue: 2014-11-20 Page 1 of 4 Certificate history: Issue No. 1 (2014-11- 20) Issue No. 0 (2013-11- 25) Applicant: Littelfuse Philippines, Inc Lima Technology Centre Special Economic Zone Lipa City-Malvar Batangas Philippines Electrical Apparatus: Optional accessory: Intrinsic Safety Fuses, 305 and 304 Series Type of Protection: Intrinsic Safety "ia" Marking: Ex ia IIC Approved for issue on behalf of the IECEx Certification Body: Position: Erin LaRocco Senior Project Engineer Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: UL LLC 333 Pfingsten Road Northbrook IL 60062-2096 United States of America

Certificate No.: IECEx UL 13.0077U Date of Issue: 2014-11-20 Issue No.: 1 Page 2 of 4 Manufacturer: Littelfuse Philippines, Inc Lima Technology Centre Special Economic Zone Lipa City-Malvar Batangas Philippines Additional Manufacturing location (s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition: 6.0 IEC 60079-11 : 2011 Edition: 6.0 IEC 60079-26 : 2006 Edition: 2 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: US/UL/ExTR13.0084/00 US/UL/ExTR13.0084/01 Quality Assessment Report: GB/BAS/QAR10.0018/03

Certificate No.: IECEx UL 13.0077U Date of Issue: 2014-11-20 Issue No.: 1 Page 3 of 4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: The 304 and 305 Series fuses are encapsulated fuse assemblies suitable for use in intrinsically safe apparatus and associated apparatus. Please see Annex for additional details and Schedule of Limitations for Ex Components. CONDITIONS OF CERTIFICATION: NO

Certificate No.: IECEx UL 13.0077U Date of Issue: 2014-11-20 Issue No.: 1 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Issue 1: Addition of 304 Series fuse. Annex: Annex for IECEx UL 13.0077U Issue 1.pdf

Annex for IECEx UL 13.0077U Issue 1 The 304 and 305 Series Intrinsic Safety fuses are encapsulated fuse assemblies suitable for use in intrinsically safe apparatus and associated apparatus. The model nomenclature is as follows: 0305.050 M R P I II III IV V I Series: 0304 or 304 = 304 Series 0305 or 305 = 305 Series II Current Rating.050 = 0.050 A rating.200 = 0.200 A rating.080 = 0.080 A rating.250 = 0.250 A rating.100 = 0.100 A rating.500 = 0.500 A rating.160 = 0.160 A rating.750 = 0.750 A rating III Quantity Code: Any alphanumeric character(s) representing number of pieces in package IV Packaging Code (304 Series only): Any alphanumeric character(s) representing the type of package V Lead-Free Code (optional): P = Lead-free solder

Temperature range(s): The 304 and 305 Series Intrinsic Safety fuses are suitable for use in the following ambient temperature ranges. The limits are based on the application of 1.7 times the nominal current rating, In, of the fuse, temperature rise characteristics and the maximum operating temperature of the encapsulation: Cat. No. 305 Series 304 Series Nominal Current Rating, In Ambient Temperature Range 0.200 A -40 C to +50 C 0.250 A -40 C to +46 C 0.500 A -40 C to +74 C 0.750 A -40 C to +46 C 0.200 A -40 C to +60 C 0.250 A -40 C to +56 C 0.500 A -40 C to +84 C 0.750 A -40 C to +56 C The following surface temperature rise values were measured on encapsulated samples of the components when carrying a current of 1.7 times the nominal current rating, In, of the fuse: Model Nominal Current Rating Maximum Surface Temperature Rise 0.200 A 52 C 305 Series 0.250 A 58 C 0.500 A 30 C 0.750 A 41 C 0.200 A 88 C 304 Series 0.250 A 52 C 0.500 A 52 C 0.750 A 45 C

Electrical data The 304 and 305 Series Fuses are rated 277 V AC/DC, 1500A AC/DC breaking capacity These fuses were measured as having the following minimum resistance values at the following temperatures: Model 304 and 305 Series Ampere Rating Resistance (Ω) (A) At -20 C At -40 C 0.050 9.202 9.010 0.080 6.031 5.963 0.100 2.709 2.668 0.160 2.297 2.292 0.200 1.935 1.839 0.250 1.268 1.105 0.500 0.392 0.368 0.750 0.219 0.196 Schedule of Limitations for Ex Components A temperature classification is not applied to Ex Components per Annex B, Note 2 of IEC 60079-0. The fuses have been evaluated for use in the following ambient temperature ranges: Cat. No. 305 Series 304 Series Nominal Current Rating, In 0.200 A Ambient Temperature Range -40 C to +50 C 0.250 A -40 C to +46 C 0.500 A -40 C to +74 C 0.750 A -40 C to +46 C 0.200 A -40 C to +60 C 0.250 A -40 C to +56 C 0.500 A -40 C to +84 C 0.750 A -40 C to +56 C Use of the fuses outside of the ambient temperature ranges specified in the table is subject to additional investigation. These components have been judged on the basis of spacings in accordance with Table 5 of IEC 60079-11, and are considered suitable for use in circuits with peak voltages not exceeding 375 V based on these separation distances alone.