Chassis Inverter power Rated input Rated output Battery pack Safeties Environment Others Input Voltage Lower Limit Input Voltage Upper Limit Power Input Current Output Voltage Output accuracy Transient Transient recovery time Frequency tracking CENTAURI ENERGY SERVER TECHNICAL DATA - 160 kw POWER Input Output Operating temperature relative humidity altitude Cooling Noise Mean time between failures (MTBF) Protection grade (EN60529) Incoming line way Standards Dimensions (W*D*H) Packing (W*D*H) Weight 160kW 250A 360V 440VAC 380V 440VAC +240VDC and -240VDC MCCB: 800V, 250A, 8kA rupturing capacity Surge and Spike Filtration: Varistor 460VAC ±10% MCCB: 800V, 250A, 8kA rupturing capacity Surge and Spike Filtration: Varistor 460VAC ±10% 0~40 90% (Non-condensing) Rated power per 100m (1% reduced by rising 100m) 4000m Forced ventilation (fan speed varies with load) 60 db (changes with different load and temperature) 200,000 hours IP20 Lower wiring pattern IEC62040-1-1, EN62109-1:2010, EN62109-2:2011 980mm*800mm*1800mm 1050mm*870mm*2030mm ~960 kg (all modules inserted) 200VDC and -200VDC 290VDC and -290VDC 100A 380VAC 440VAC (programmable / adjustable) ±1% ±5% 2 50Hz/60Hz ±1Hz (pre-settable) 50Hz/60Hz ±3 Hz Crest factor 3:01
Bypass PV Grid / AC Rectifier Waveform Waveform distortion factor Voltage imbalance Overload Torque load handling Short circuit Rated 105%-110% 110%-125% 125%-150% High resolution pure sine wave 1024 bits per quarter cycle 3% (Linear load) ±3% (100% unbalanced load) 1 hour, then switches to bypass mode 10 mins, then switches to bypass mode 60 secs, then switches to bypass mode 150% 10 secs after which system shuts down. Reduce load to boot 200% 8 secs after which the system shuts down. Reduce load to boot 1000% 2 secs The system starts limited operation & immediately shuts down, while the user should confirm boot 93% Three-phase-four-wire +G 380VAC Voltage ±20% (Voc) Best working (Vmp) conversion Equal charging pressure charging working power of solar panel (kw) PV input channels Proton Exchange / MPPT module Range of input Frequency Soft start 50Hz/60Hz ±5Hz 30A 0 V - 750VDC 450-550VDC 98% 414V ±1% 428V ±1% 400A 400A 160 kw (extendable to 500kW) 1+1 (Reserved) 4 +2 (Reserved) Three phase 380V ±20% 50Hz / 60Hz (Background Setting) 50Hz / 60Hz ±1Hz 0-100% 10s Power factor Max. 0.8 (20 ) 410V ±1% 415V ±1%
charging within permitted of battery capacity Over discharge limit Charging Settings 120A 315VDC Factory setting 0.15C10 User Setting 0.07-0.3C10 Battery Management (Lead Acid all types, AGM, Gel, Carbon+ and Flooded batteries), Li Ion all types, Sirius all types Switching Communication and Automation Diesel Generator Intelligent battery management Depth of discharge setting for off-peak discharging Battery SOC Inverter / bypass Bypass / inverter Inverter / grid Grid / inverter DG / inverter Inverter / DG Energy blending Remote control input Computer monitoring port Dry contact output 12VDC/250Vac 1A max Range of input Frequency Soft start Automatic conversion between even charging and floating charging; Automatic temperature compensation of battery pack (If the system is not connected with the detection line for the battery temperature, the temperature compensation is based on the ambient temperature) 330VDC-378VDC (Pre-settable) No. of channels 20 time accuracy topology 4ms 4ms 1 3 hours ±1% Cell to cell 12V / 2V Available / programmable between all input modules (PV, wind, grid, DG) Battery self-check, Server ON/OFF, fault clear, emergency stop RS232, RS485 and SNMP Bypass input fault, rectifier input fault, system fault, system alarm, battery low, output overload, fan fault and generator ON/OFF. Three phase 380V ±20% 50Hz / 60Hz (Background Setting) 50Hz / 60Hz ±10Hz 0-100% 25s Power factor Max. 0.8 (20 ) 410V ±1% 415V ±1%
Wind Grid-tied module charging within permitted of battery capacity point tracking Automatic switching Protections Shutdown Rated Power Wind turbine Load on Wind turbine automatic breaking Recovery time after automatic breaking No load loss Buck & boost function DC input Max DC input Voltage Start Voltage Rated Voltage DC input Max input MPPT ways AC output parameters Rated AC output power Max rated AC output power Max AC output Rated AC output Rated grid frequency 120A Available with load, frequency, power and temperature input Engine switching and load switching available Cranking battery charge maintenance Overload Over temperature Over Frequency below and above permitted Engine airlock prevention 280VDC 440VDC 75A 280VDC 440VDC 500VDC after rectification 10 mins (default adjustable) 45mA Available 500VDC 100VDC 380VDC 80VDC 500VDC 250A 4-way 22kW 100A 220V/230V/240V;180-270V 50HZ ±5Hz 60HZ ±5Hz
Safety devices Environment Power factor 1 Output harmonics <3% Max 97% European 96% MPPT 99.9% DC input reverse polarity Input DC impedance monitor Leak AC short circuit Mains monitor Output DC component monitor Anti-islanding Operating temperature Relative humidity IP Night consumption -25 75 0% - 95% non-condensable IP20 0.5W